Fibre Small Form Pluggable Transceivers with Built-in ... · • Integral Micro-OTDR SFP...
Transcript of Fibre Small Form Pluggable Transceivers with Built-in ... · • Integral Micro-OTDR SFP...
Certified iSFPs/SFP+
Fibre Small Form Pluggable Transceivers with Built-in Micro OTDR
www.net2edge.com | Tel: +44 (O) 345 O13OO3O2
• Integral Micro-OTDR SFP Transceiver
• Dual Fibre, Full Duplex, SFP
• Dead Zone of 30 metres or Less
• Resolution of 10 metres or Better
• Accuracy of 50 metres or Better
• Minimum 34 dB Link Budget for FE Data Model
• Minimum 26dB Link Budget for GbE Data Model
• Minimum 65dB Dynamic Range for the TxOTDR™
• Automatically Transitions to Micro-OTDR Mode
• Operates Anywhere Conventional SFPs
• Low power dissipation <1.5W
• Available operating temperature range: -20°C to 85°C
Net2Edge provides advanced optical solutions through Intelligent Optical Transceivers (iSFP/iSFP+). The portfolio includes an iSFP with integrated Micro-OTDR (uOTDR™) that automatically Detects, Locates and Reports Optical Fibre Faults.
Designed in conformance with the Small Form Factor Pluggable 20-pin Multi-Source Agreement (MSA) is available to facilitate integration within existing equipment and management systems. It comes with
SNMP management interface that allows configuration and helps to monitor relevant parameters.
iSFP-uOTDR Series SFP Transceivers transmit and receive full duplex data over conventional two-fibre optical communication links. Upon disruption of the data link, or failure to connect, the Transmitter Section of the SFP unit switches into TxOTDR™ Mode, emitting optical power pulses (> +13 dBm) and detecting the reflected pulses at least down to -52 dBm optical power.
Overview
Data Sheet
Providing advanced optical solutions
through Intelligent Optical Transceivers
(iSFP/iSFP+)
IDFC™ Series
Product Features
Description
Dual Fibre, full duplex SFP with Built-in Micro-OTDR
www.net2edge.com | Tel: +44 (O) 345 O13OO3O3
Data Sheet
iSPF-OTDR
The integration of a Micro-OTDR into an SFP greatly reduces Network Mean-Time-To-Repair (MTTR) by Identifying the Cable Fault location without having to send a technician with a field OTDR, and brings CAPEX and OPEX savings. Other major benefits are:
• Physical Layer Fault Detection
• Distributed Remote Fibre Monitoring
• No Additional Special Equipment
• Eliminates Fault Detection Delay
Fibre faults and intermittent connections present optical reflections of varying intensities. The reflection intensity of a fibre break has a known statistical distribution.
Monitoring multiple fibres in the same trunk increases the detection probability (each fibre breaks differently). A fibre link may be monitored from one side, or both
Automatically Detects, Locates and Reports Optical Fibre Faults.
Fibre Fault Detection from one end - randomly distributed fault Fibre Fault Detection from at least one end
Value Proposition
www.net2edge.com | Tel: +44 (O) 345 O13OO3O4
Data Sheet
iSPF-OTDR
Parameter Symbol Min Typical Max Unit
Absolute Supply Voltage Vcc_max 0 - 3.6 V
Operating Case Temperature Top -20 - +70 °C
Operating Relative Humidity RHop 5 - +95 %
Storage and Transportation Temperature Tst -40 - +85 °C
Parameter Symbol Min Typ Max Min Typ Max Unit
Average Optical Output Power – FastE Po -2 0 1 -2 0 1 dBm
Output Eye Conformance IEEE 802.3-2008 SONET OC-3 SDH STM-1
IEEE 802.3-2008
Receiver (Ethernet Sensitivity/Overload referenced to BER < 10E-12 with 2^7-1 PRBS; SONET/SDH Sensitivity and Overload referenced to BER < 10E-10 with 2^23-1 PRBS.)
Parameter at Specified Bit Rate (Mbps) Symbol 125 - 156 125 - 1250 Unit
Average Output Power 34 - 34 19 - 26 dBm
Average Output Power 32 - 32 17 - 24 dBm
Parameter Symbol Min Typ Max Min Typ Max Unit
Average Optical Input Power – FastE PMin - - -36 - - -28 dBm
Loss Of Signal De-Asserted – FastE PD - -37 - - -29 - dBm
Loss Of Signal Asserted – FastE PA - -38 - - -30 - dBm
Output Eye Conformance IEEE 802.3-2008 SONET OC-3 SDH STM-1
IEEE 802.3-2008
Link
Reach Category: Ultra-Long Reach1OO Km Class
Ultra-Long Reach8O Km Class
Model Series: S-Series(FastE / OC-3 / STM-1)
C-Series(FastE / GbE)
Part Nomenclature: Duplex LC/UPCReceptacle:
EN-iSFPFE-AF1OOCxx EN-iSFP1G-AFXOCxx
Transmitter
Recommended Operating Conditions
Optical Characteristics
(-2OºC to +7OºC)
www.net2edge.com | Tel: +44 (O) 345 O13OO3O5
Data Sheet
iSPF-OTDR
Standards & Compliance
Ordering Information
Compatibility; Tested and Proven
• Proven Compatibility and Interoperability with; Cisco, Juniper, ALCATEL-LUCENT, ADVA, Brocade, CIENA, Huawei, PacketLight, Transmode, NEtInsight, ToyoTech, etc.
Regulatory Compliance
• Test and Visibility equipment such as; IXIA, GIGAMON, VSS, SPIRENT, JDSU, XENA, EXFO, etc. Regulatory Compliance
• The Smart iSFP complies with international Electromagnetic Compatibility (EMC) and international safety requirements and standards.
• EMC performance is dependent on the overall system design.
• The Smart iSFP is lead-free and RoHS2-compliant per Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
Part Number Description Data Rate Connector Distance (km)
iSFP-uOTDR 1GbE/CWDM (xx=ITU Ch# 1271-1611nm)
EN-iSFP1G-AO4OCxx OTDR Reflector 1000BASE-EX SFP, 40kmover SMF iDFC GbE 1xx1 nm DFB 20dB DRDuplex LC/UPC Receptacle
1.25G LC 40
EN-iSFP1G-AF4OCxx uOTDR 1000BASE-EX SFP, 40km over SMF,iDFC GbE 1xx1nm DFB 20 dB uOTDR 65dBDR Duplex LC/UPC Receptacle
1.25G LC 40
EN-iSFP1G-AO8OCxx OTDR Reflector 1000BASE-ZX SFP, 80kmover SMF iDFC GbE 1xx1nm DFB 26dB DRDuplex LC/UPC Receptacle
1.25G LC 80
EN-iSFP1G-AF8OCxx uOTDR 1000BASE-ZX SFP, 80km over SMF,iDFC GbE 1xx1nm DFB 26dB uOTDR 65dBDR Duplex LC/UPC Receptacle
1.25G LC 80
iSFP-uOTDR FE Fast Ethernet (xx= ITU CH #1271-1611nm)
EN-iSFPFE-AO1OOCxx OTDR Reflector FastE SFP, 100km over SMFiDFC FE 1xx1nm DFB 34dB DR Duplex LC/UPC Receptacle
FastE/OC-3/STM-1
LC 100
EN-iSFPFE-AF1OOCxx uOTDR FastE SFP, 100km over SMF, iDFC FE1xx1nm DFB 34dB uOTDR 65dB DR DuplexLC/UPC Receptacle
FastE/OC-3/STM-1
LC 100
www.net2edge.com | Tel: +44 (O) 345 O13OO3O6
Data Sheet
iSPF-OTDR
• Integral Micro-OTDR SFP Transceiver
• Single Fiber, Full Duplex, SFP
• SC or LC connector available
• Dead Zone of 30 metres or Less
• Resolution of 10 metres or Better
• Accuracy of 50 metres or Better
• Minimum 20 dB Optical Link Budget
• 55 dB Dynamic Range for the uOTDR
• Reflection Immune Operation – Any Network Type
• Automatically Transitions to Micro-OTDR Mode
• Low power dissipation <1.5W
• Available operating temperature range: -20°C to 70°C
Net2Edge provides advanced optical solutions through Intelligent Optical Transceivers (iSFP/iSFP+). The portfolio includes an iSFP with integrated Micro-OTDR (uOTDR™) that automatically Detects, Locates and Reports Optical Fiber Faults.
Designed in conformance with the Small Form Factor Pluggable 20-pin Multi-Source Agreement (MSA) is available to facilitate integration within existing equipment and management systems.
It comes with SNMP management interface that allows configuration and helps to monitor relevant parameters. iSFP-uOTDR Series SFP Transceivers transmit and receive at the same wavelength, doubling the optical fiber plant capacity. Upon disruption of data link, or failure to connect, the unit switches into uOTDR Mode, emitting optical power pulses (>+13 dBm) and detecting the reflected pulses at least down to -42 dBm optical power.
Reflection Immune Operation resolves self-reflection from an open connector and/or other reflectors. Only remote data is transferred into the host equipment.
Overview
Reflection Immune Operation resolves
self-reflection from an open connector and/
or other reflectors.
Product Features
Description
Single Fibre SFP with Built-in Micro-OTDR
Data Sheet
IDFC™ Series
www.net2edge.com | Tel: +44 (O) 345 O13OO3O7
Data Sheet
iSPF-OTDR
The integration of a Micro-OTDR into an SFP greatly reduces Network Mean-Time-To-Repair (MTTR) by Identifying the Cable Fault location without having to send a technician with a field OTDR, and brings CAPEX and OPEX savings. Other major benefits are:
• Physical Layer Fault Detection
• Distributed Remote Fibre Monitoring
• No Additional Special Equipment
• Eliminates Fault Detection Delay
Automatically Detects, Locates and Reports Optical Fibre Faults
Fibre faults and intermittent connections present optical reflections of varying intensities. The reflection intensity of a fibre break has a known statistical distribution. Monitoring multiple fibres in the same trunk increases the detection probability (each fibre breaks differently). A fibre link may be monitored from one side, or both sides, for example, when ring topology is utilized.
Fibre Fault Detection from at least one end
Value Proposition
www.net2edge.com | Tel: +44 (O) 345 O13OO3O8
Data Sheet
iSPF-OTDR
Parameter Symbol Min Typical Max Unit
Absolute Supply Voltage Vcc_max 0 - 3.6 V
Operating Case Temperature Top -20 - +70 °C
Operating Relative Humidity RHop 5 - +95 %
Storage and Transportation Temperature Tst -40 - +85 °C
Parameter Symbol Min Typ Max Unit
Average Optical Output Power – FastE/GbE Po -2 0 1 dBm
Output Eye Conformance IEEE 802.3-2008
Receiver GbE Sensitivity/Overload referenced to BER < 10E-12 with 2^7-1 PRBS)
Parameter Symbol Min Typ Max Unit
Average Optical Input Power – FastE Pmin - -23 -22 dBm
Loss Of Signal De-Asserted – FastE PD - -23 - dBm
Loss Of Signal Asserted – FastE PA - -25 - dBm
Output Eye Conformance IEEE 802.3-2008
Link (*Note: FastE Sensitivity penalty is 7dB)
Parameter at Specified Bit Rate (Mbps) Symbol 125 - 1250 Unit
Minimum Data Sheet Optical Power Budget 13 - 20 dBm
Minimum Planning Optical Power Budget 11 - 18 dBm
Minimum Required Optical Return Loss ORL 24 - 24 dBm
Reach Category: Category: Medium Reach 4O km Class
Model Series: C-Series (FastE / GbE)
Part Nomenclature: Duplex LC/UPC Receptacle: EN-iSFPBX-AFXOCxx
Transmitter
Recommended Operating Conditions
Optical Characteristics
(-2OºC to +7OºC)
www.net2edge.com | Tel: +44 (O) 345 O13OO3O9
Data Sheet
iSPF-OTDR
Standards & Compliance
Ordering Information
Compatibility; Tested and Proven
• Proven Compatibility and Interoperability with; Cisco, Juniper, ALCATEL-LUCENT, ADVA, Brocade, CIENA, Huawei, PacketLight, Transmode, NEtInsight, ToyoTech, etc.
• Test and Visibility equipment such as; IXIA, GIGAMON, VSS, SPIRENT, JDSU, XENA, EXFO, etc.
Regulatory Compliance
• The Smart iSFP complies with international Electromagnetic Compatibility (EMC) and international safety requirements and standards.
• EMC performance is dependent on the overall system design.
• The Smart iSFP is lead-free and RoHS2-compliant per Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
Part Number Description Data Rate Connector Distance (km)
iSFP-uOTDR 1GbE/CWDM (xx=ITU Ch# 1311, 1451, 1471, 1491, 1511, 1531, 1551, 1571, 1591, 1611nm)
EN-iSFPBX-AO4OCxx OTDR REFLECTOR 1000BASEEX SFP, 40kmover SMF iSFC GbE 1xx1 nm DFB 20 dB DRSingle Fibre LC/UPC Receptacle
1.25G LC 40
EN-iSFPBX-AF4OCxx uOTDR 1000BASE-EX SFP, 40km over SMF,iSFC GbE 1xx1 nm DFB 20 dB uOTDR 55 dBDR Single Fibre LC/UPC Receptacle
1.25G LC 40
iSFP-uOTDR FE Fast Ethernet (xx= ITU CH #1311, 1451, 1471, 1491, 1511, 1531, 1551, 1571, 1591, 1611nm)
EN-iSFPBX-AO8OCxx OTDR REFLECTOR FastE SFP, 100km overSMF iSFC FE 1xx1 nm DFB 34 dB DR SingleFibre LC/UPC Receptacle
FastE LC 80
EN-iSFPBX-AF8OCxx uOTDR FastE SFP, 100km over SMF, iSFC FE1xx1 nm DFB 34 dB uOTDR 65 dB DR singlefibre LC/UPC Receptacle
FastE LC 80
[email protected]+44 (0) 345 0130 030
Net2Edge Limited, Kulite House, Stroudley RoadBasingstoke Hampshire RG24 8UG United Kingdom
2019 v10