Fiber Optic Cables 2018
Transcript of Fiber Optic Cables 2018
Fiber Optic Cables 2018Reichle & De-Massari Czech Republic a.s. R&M offers a broad range of fiber optic cables for applications in Local Area Networks, Data Centers and Telecom.
030.
5943
2
R&M generates added value. Connectivity that matters.
Our motto: Experience – Quality – Flexibility!
Experience We have carefully selected staff with long time experience at designing and manufacturing of fibre optic cables.
Quality All used materials are subjected to input con-trol. Every production process is finished by measurement of each fibre, complete cables then by complex output-control documented always by Final Test Protocol, which is integral part of each supplied cable.
FlexibilityWe are prepared to offer cables according to your needs in the shortest possible term, of course.
We are focussed on manufacture of flame-re-tardant to EN 60332-3 and fire-resistant to EN 60331-25 loose-tube constructions tested in accordance with IEC 60794-1-2 standard.
Loose-tube cables can contain either one single tube with coloured optical fibres (central-loose-tube = CLT), either multiple tubes (Multi Loose Tube = MLT). We use either FRLSZH (Fire-Re-tardant, Low-Smoke, Zero-Halogen) jacketing compounds for indoor or universal (indoor/outdoor) installation either PE (Polyethylene) compounds for outdoor installation as well as other special compounds.
Reichle & De-Massari Czech Republic a.s. offers range of cable constructions with increased resistance to mechanical damage (like Steel-Wire-Armoured or Corrugated-Steel-Tape armoured) suitable for direct burial installation.
Production of Fibre Optic Cables
3
Reichle & De-Massari Czech Republic a.s.
Sales Support
František MaczákSales Manager – FOC+420 737 220 [email protected]
Zuzana MichalscakovaInside Sales Manager – FOC+420 412 548 [email protected]
Reichle & De-Massari Czech Republic a.s.Vítězství 67405 02 Děčín 33 – Nebočadywww.rdm-czech.com
Product Management
Lars ZuelligProduct Manager – FOC+41 44 933 84 [email protected]
Reichle & De-Massari AG – HeadquartersBinzstrasse 328620 Wetzikon – Switzerlandwww.rdm.com
About us
Transportkabel-DIXI Inc. has been founded in 1996 as a supplier of technologies and machinery for the cable manufacturing and cable handling. The Company processes his own construction, engineer-ing and manufacturing capacities including his own production and testing line. The Company is also closely cooperating with cable manufacturing plants.
In beginning of 2018 Reichle & De-Massari (R&M), the Swiss developer and provider of connectivity systems for network infra-structure has acquired Transportkabel – DIXI (TK DIXI) in order to enhance its end-to-end fibre optic cable offering. Founded more than 20 years ago, R&M develops and manufactures fibre optic and metallic cables for power and communication applications in data centres, broadband networks, enterprise buildings and other infrastructure projects.
5
Central Loose Tube Cables – CLT 6Overview 8
Microcables 12
All-dielectric Duct Cables 20
All-dielectric Duct Cables with improved rodent protection 28
Steel Wire Armoured Cables – SWA 36
Corrugated Steel Tape Armoured Cables – CSTA 42
Fiber Reinforced Plastic Rod Armoured Cables – FRPA 52
Fire Resistant Cables – All-dielectric Non-armoured 56
Fire Resistant Cables – Corrugated Steel Tape Armoured 60
Fire Resistant Cables – Steel Wire Armoured Cables 64
Multi Loose Tube Cables – MLT 70Overview 72
Microcables 76
All-dielectric Duct Cables 82
All-dielectric Duct Cables with improved rodent protection 90
Steel Wire Armoured Cables – SWA 98
Corrugated Steel Tape Armoured Cables – CSTA 102
Fire Resistant Cables – All-dielectric Non-armoured 110
Fire Resistant Cables – Corrugated Steel Tape Armoured 112
Fire Resistant Cables – Steel Wire Armoured Cables 114
FTTx Constructions 116Overview 118
Microcables 120
Flat self-supporting cables 122
Non-metallic drop cables 126
Sensor Cables 130
Explanations 134Fiber specifications 135
DIN/VDE 0888 cable coding 136
Color codes 137
Coding of FOC constructions 138
CPR 140
6
R&M generates added value. Connectivity that matters.Central Loose Tube Cables. CLT.
8
R&M generates added value. Connectivity that matters.
Central Loose Tube Cables Overview
Microcables
MT1H 12 MT1H xx.yy.zz.c outdoor 12 fibers HDPE
MX1H 14 MX1H xx.yy.zz.c outdoor 24 fibers HDPE
MT1F 16 MT1F xx.yy.zz.c indoor/outdoor 12 fibers FRLSZH
MX1F 18 MX1F xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
All-dielectric duct cables with standard rodent protection
OT1EL 20 OT1EL xx.yy.zz.c outdoor 12 fibers LDPE
OX1EL 22 OX1EL xx.yy.zz.c outdoor 24 fibers LDPE
UT1EF 24 UT1EF xx.yy.zz.c indoor/outdoor 12 fibers FRLSZH
UX1EF 26 UX1EF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
All-dielectric duct cables with improved rodent protection
OT1GL 28 OT1GL xx.yy.zz.c outdoor 12 fibers LDPE
OX1GL 30 OX1GL xx.yy.zz.c outdoor 24 fibers LDPE
UT1GF 32 UT1GF xx.yy.zz.c indoor/outdoor 12 fibers FRLSZH
UX1GF 34 UX1GF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
Steel wire armoured cables – SWA
OX1ELWH 36 OX1ELWH xx.yy.zz.c outdoor 24 fibers HDPE
UX1ELWF 38 UX1ELWF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
UX1EFWF 40 UX1EFWF xx.yy.zz.c indoor/outdoor
Corrugated steel tape armoured cables, single jacketed – CSTA
OX1ECH 42 OX1ECH xx.yy.zz.c outdoor 24 fibers HDPE
UX1ECF 44 UX1ECF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
Corrugated steel tape armoured cables, double jacketed – CSTA
OX1ELCH 46 OX1ELCH xx.yy.zz.c outdoor 24 fibers HDPE
UX1ELCF 48 UX1ELCF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
UX1EFCF 50 UX1EFCF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
Cable type Construction Page Construction code Application Fiber count Jacket material Euro classification to CPR
Nominal cable Ø [mm]
Cable weight [kg/km]
Tensile performance [N]
Crush [N/100mm]
Temperatur range in operation
Fire resistance – EN 60331-25
9
Microcables
MT1H 12 MT1H xx.yy.zz.c outdoor 12 fibers HDPE
MX1H 14 MX1H xx.yy.zz.c outdoor 24 fibers HDPE
MT1F 16 MT1F xx.yy.zz.c indoor/outdoor 12 fibers FRLSZH
MX1F 18 MX1F xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
All-dielectric duct cables with standard rodent protection
OT1EL 20 OT1EL xx.yy.zz.c outdoor 12 fibers LDPE
OX1EL 22 OX1EL xx.yy.zz.c outdoor 24 fibers LDPE
UT1EF 24 UT1EF xx.yy.zz.c indoor/outdoor 12 fibers FRLSZH
UX1EF 26 UX1EF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
All-dielectric duct cables with improved rodent protection
OT1GL 28 OT1GL xx.yy.zz.c outdoor 12 fibers LDPE
OX1GL 30 OX1GL xx.yy.zz.c outdoor 24 fibers LDPE
UT1GF 32 UT1GF xx.yy.zz.c indoor/outdoor 12 fibers FRLSZH
UX1GF 34 UX1GF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
Steel wire armoured cables – SWA
OX1ELWH 36 OX1ELWH xx.yy.zz.c outdoor 24 fibers HDPE
UX1ELWF 38 UX1ELWF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
UX1EFWF 40 UX1EFWF xx.yy.zz.c indoor/outdoor
Corrugated steel tape armoured cables, single jacketed – CSTA
OX1ECH 42 OX1ECH xx.yy.zz.c outdoor 24 fibers HDPE
UX1ECF 44 UX1ECF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
Corrugated steel tape armoured cables, double jacketed – CSTA
OX1ELCH 46 OX1ELCH xx.yy.zz.c outdoor 24 fibers HDPE
UX1ELCF 48 UX1ELCF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
UX1EFCF 50 UX1EFCF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
3.0 8.0 50 500 -20°C to 70°C
4.0 14.0 50 500 -20°C to 70°C
Fca 3.0 10.0 50 500 -30°C to 70°C
Fca 4.0 17.0 50 500 -30°C to 70°C
5.8 29.0 1'000 2'000 -20°C to 70°C
6.5 37.0 1'000 2'000 -20°C to 70°C
Dca-s2,d1,a1 5.2 33.0 1'000 2'000 -30°C to 70°C
Dca-s2,d1,a1 5.8 41.0 1'000 2'000 -30°C to 70°C
6.5 37.0 1'800 2'000 -20°C to 70°C
7.4 50.0 2'000 2'000 -20°C to 70°C
Dca-s2,d1,a1 6.2 45.0 1'800 2'000 -30°C to 70°C
Dca-s2,d1,a1 7.2 58.0 2'000 2'000 -30°C to 70°C
9.9 150.0 4'500 4'000 -20°C to 70°C
Fca 9.9 170.0 4'500 4'000 -20°C to 70°C
Dca-s2,d2,a1 9.9 180.0 4'500 4'000 -30°C to 70°C
7.7 70.0 1'500 5'000 -20°C to 70°C
Dca-s2,d2,a1 7.7 84.0 1'500 5'000 -30°C to 70°C
10.0 100.0 1'500 5'000 -20°C to 70°C
Fca 10.0 115.0 1'500 5'000 -30°C to 70°C
Cca-s1,d0,a1 10.0 125.0 1'500 5'000 -30°C to 70°C
Cable type Construction Page Construction code Application Fiber count Jacket material Euro classification to CPR
Nominal cable Ø [mm]
Cable weight [kg/km]
Tensile performance [N]
Crush [N/100mm]
Temperatur range in operation
Fire resistance – EN 60331-25
10
R&M generates added value. Connectivity that matters.
Central Loose Tube Cables Overview
Fiber reinforced plastic rod armoured cables – FRPA
OX1PH 52 OX1PH xx.yy.zz.c outdoor 24 fibers HDPE
UX1PF 54 UX1PF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
Fire resistant cables – All-dielectric, non-armoured
QT1GF 56 QT1GF xx.yy.zz.c indoor/outdoor 12 fibers FRLSZH
QX1GF 58 QX1GF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
Fire resistant cables – Corrugated steel tape armoured – CST
QX1ECF 60 QX1ECF xx.yy.zz.c indoor/outdoor 12 fibers FRLSZH
QX1EFCF 62 QX1EFCF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
Fire resistant cables – Steel wire armoured cables – SWA
QX1EFWF 64 QX1EFWF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
QX1ELWF 66 QX1ELWF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
QX1EFWFc 68 QX1EFWFc xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
Cable type Construction Page Construction code Application Fiber count Jacket material Euro classification to CPR
Nominal cable Ø [mm]
Cable weight [kg/km]
Tensile performance [N]
Crush [N/100mm]
Temperatur range in operation
Fire resistance – EN 60331-25
11
7.4 52.0 2'500 3'000 -20°C to 70°C
Fca 7.4 65.0 2'500 3'000 -30°C to 70°C
Dca-s1,d1,a1 7.0 58.0 2'000 2'000 -30°C to 70°C 180 min at 750°C
Dca-s2,d1,a1 7.8 68.0 2'000 2'000 -30°C to 70°C 180 min at 750°C
Fca 8.0 90.0 1'500 5'000 -30°C to 70°C 180 min at 750°C
Fca 11.0 150.0 1'500 5'000 -30°C to 70°C 180 min at 750°C
Fca 10.1 185.0 4'500 4'000 -20°C to 70°C 180 min at 750°C
Fca 10.1 185.0 4'500 4'000 -20°C to 70°C 180 min at 750°C
Fca 10.1 185.0 4'500 4'000 -20°C to 70°C 180 min at 750°C
Fiber reinforced plastic rod armoured cables – FRPA
OX1PH 52 OX1PH xx.yy.zz.c outdoor 24 fibers HDPE
UX1PF 54 UX1PF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
Fire resistant cables – All-dielectric, non-armoured
QT1GF 56 QT1GF xx.yy.zz.c indoor/outdoor 12 fibers FRLSZH
QX1GF 58 QX1GF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
Fire resistant cables – Corrugated steel tape armoured – CST
QX1ECF 60 QX1ECF xx.yy.zz.c indoor/outdoor 12 fibers FRLSZH
QX1EFCF 62 QX1EFCF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
Fire resistant cables – Steel wire armoured cables – SWA
QX1EFWF 64 QX1EFWF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
QX1ELWF 66 QX1ELWF xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
QX1EFWFc 68 QX1EFWFc xx.yy.zz.c indoor/outdoor 24 fibers FRLSZH
Cable type Construction Page Construction code Application Fiber count Jacket material Euro classification to CPR
Nominal cable Ø [mm]
Cable weight [kg/km]
Tensile performance [N]
Crush [N/100mm]
Temperatur range in operation
Fire resistance – EN 60331-25
12
R&M generates added value. Connectivity that matters.Cable construction code DIN code
MT1H xx.yy.zz.c A-D2Y
1. Gel filled PBT loose tube with optical fibers2. HDPE UV stable outer jacket
Cable general description
Max. 12 fiber uni-tube non-metallic micro-cable for outdoor installation to micro-tubes.
Construction and dimensions
Loose tube nominal diameter 2,0 mm
Outer jacket nominal thickness 0,5 mm
Cable nominal outer diameter 3,0 mm
Cable informative weight 8 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable HDPE
Jacket colour Black
Sheath marking Ink-Jet, white
Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Microcables MT1H
13
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 50 N (short term) Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 500 N/100mm (short term) Δα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 1 Nm, 3 impacts, d=20 mm,R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R = 40 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Kink EN 60794-1-21:E10 d = 40 x cable diameter no damage
Bend no tension EN 60794-1-21:E11A R=40 x cable diameter, 4 turns,3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-30°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-20°C ÷ 70°C-30°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-5-10 Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
MT1H Ø 3,0
4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B
6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B
8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B
12 01.12.M3.B 01.12.M4.B 01.12.M5.B R848278 01.12.S7.B
Order code e.g.: MT1H 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Central Loose Tube Cables
14
R&M generates added value. Connectivity that matters.Cable construction code DIN code
MX1H xx.yy.zz.c A-D2Y
1. Gel filled PBT loose tube with optical fibers2. HDPE UV stable outer jacket
Cable general description
Max. 24 fiber uni-tube non-metallic micro-cable for outdoor installation to micro-tubes.
Construction and dimensions
Loose tube nominal diameter 3,0 mm
Outer jacket nominal thickness 0,5 mm
Cable nominal outer diameter 4,0 mm
Cable informative weight 14 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable HDPE
Jacket colour Black
Sheath marking Ink-Jet, white
Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Microcables MX1H
15
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 50 N (short term) Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 500 N/100mm (short term) Δα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 1 Nm, 3 impacts, d=20 mm,R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R = 40 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Kink EN 60794-1-21:E10 d = 40 x cable diameter no damage
Bend no tension EN 60794-1-21:E11A R=40 x cable diameter, 4 turns,3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-30°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-20°C ÷ 70°C-30°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-5-10 Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
MX1H Ø 4,0
16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B
20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B
24 01.24.M3.B 01.24.M4.B 01.24.M5.B R848279 01.24.S7.B
Order code e.g.: MX1H 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Central Loose Tube Cables
16
R&M generates added value. Connectivity that matters.Cable construction code DIN code
MT1F xx.yy.zz.c J/A-DH
1. Gel filled PBT loose tube with optical fibers2. FRLSZH UV stable outer jacket
Cable general description
Max. 12 fiber uni-tube non-metallic micro-cable for indoor or outdoor installation to micro-tubes.
Construction and dimensions
Loose tube nominal diameter 2,0 mm
Outer jacket nominal thickness 0,5 mm
Cable nominal outer diameter 3,0 mm
Cable informative weight 10 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Microcables MT1F
17
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 50 N (short term) Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 500 N/100mm (short term) Δα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 1 Nm, 3 impacts, d=20 mm,R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R = 40 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Kink EN 60794-1-21:E10 d = 40 x cable diameter no damage
Bend no tension EN 60794-1-21:E11A R=40 x cable diameter, 4 turns,3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-5-10
Fire performance
Euro classification to CPR EN 50575, EN 13501-6 Fca
Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
MT1F Ø 3,0 Fca
4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B
6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B
8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B
12 01.12.M3.B R848280 01.12.M5.B 01.12.S2.B R848281
Order code e.g.: MT1F 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Central Loose Tube Cables
18
R&M generates added value. Connectivity that matters.Cable construction code DIN code
MX1F xx.yy.zz.c J/A-DH
1. Gel filled PBT loose tube with optical fibers2. FRLSZH UV stable outer jacket
Cable general description
Max. 24 fiber uni-tube non-metallic micro-cable for indoor or outdoor installation to micro-tubes.
Construction and dimensions
Loose tube nominal diameter 3,0 mm
Outer jacket nominal thickness 0,5 mm
Cable nominal outer diameter 4,0 mm
Cable informative weight 17 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Microcables MX1F
19
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 50 N (short term) Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 500 N/100mm (short term) Δα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 1 Nm, 3 impacts, d=20 mm,R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R = 40 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Kink EN 60794-1-21:E10 d = 40 x cable diameter no damage
Bend no tension EN 60794-1-21:E11A R=40 x cable diameter, 4 turns,3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-5-10
Fire performance
Euro classification to CPR EN 50575, EN 13501-6 Fca
Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
MX1F Ø 4,0 Fca
16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B
20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B
24 01.24.M3.B R848282 01.24.M5.B 01.24.S2.B R848283
Order code e.g.: MX1F 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Central Loose Tube Cables
20
R&M generates added value. Connectivity that matters.Cable construction code DIN code
OT1EL xx.yy.zz.c A-DQ(ZN)2Y wbg
1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. LDPE UV stable outer jacket
Cable general description
Max. 12 fiber uni-tube non-metallic cable with standard level of rodent protection for outdoor duct installation.
Construction and dimensions
Loose tube nominal diameter 2,8 mm
Outer jacket nominal thickness 1,0 mm
Cable nominal outer diameter 5,8 mm
Cable informative weight 29 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable LDPE
Jacket colour Black
Sheath marking Ink-Jet, white
Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
All-dielectric Duct Cables OT1EL
21
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 300 N (long term) 1000 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-25°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-20°C ÷ 70°C-25°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
OT1EL Ø 5,8
4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B
6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B
8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B
12 01.12.M3.B 01.12.M4.B 01.12.M5.B R848284 01.12.S7.B
Order code e.g.: OT1EL 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Central Loose Tube Cables
22
R&M generates added value. Connectivity that matters.Cable construction code DIN code
OX1EL xx.yy.zz.c A-DQ(ZN)2Y wbg
1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. LDPE UV stable outer jacket
Cable general description
Max. 24 fiber uni-tube non-metallic cable with standard level of rodent protection for outdoor duct installation.
Construction and dimensions
Loose tube nominal diameter 3,5 mm
Outer jacket nominal thickness 1,1 mm
Cable nominal outer diameter 6,5 mm
Cable informative weight 37 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable LDPE
Jacket colour Black
Sheath marking Ink-Jet, white
Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
All-dielectric Duct Cables OX1EL
23
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 300 N (long term) 1000 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-25°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-20°C ÷ 70°C-25°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
OT1EL Ø 6,5
16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B
20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B
24 01.24.M3.B 01.24.M4.B 01.24.M5.B R848285 01.24.S7.B
Order code e.g.: OT1EL 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Central Loose Tube Cables
24
R&M generates added value. Connectivity that matters.Cable construction code DIN code
UT1EF xx.yy.zz.c J/A-DQ(ZN)H wbg
1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. FRLSZH UV stable outer jacket
Cable general description
Max. 12 fibre uni-tube non-metallic cable with standard rodent protection for indoor or outdoor duct installation.
Construction and dimensions
Loose tube nominal diameter 2,3 mm
Outer jacket nominal thickness 1,0 mm
Cable nominal outer diameter 5,2 mm
Cable informative weight 33 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
All-dielectric Duct Cables UT1EF
25
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
UT1EF Ø 5,2 Dca-s2,d1,a1
4 01.04.M3.B R848286 01.04.M5.B 01.04.S2.B 01.04.S7.B
6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B
8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B
12 01.12.M3.B R848287 01.12.M5.B R848288 R848289
Order code e.g.: UT1EF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 300 N (long term) 1000 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11
Fire performance
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Dca-s2,d1,a1
Cable expected lifetime / min. 30 years
Central Loose Tube Cables
26
R&M generates added value. Connectivity that matters.Cable construction code DIN code
UX1EF xx.yy.zz.c J/A-DQ(ZN)H wbg
1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. FRLSZH UV stable outer jacket
Cable general description
Max. 24 fibre uni-tube non-metallic cable with standard rodent protection for indoor or outdoor duct installation.
Construction and dimensions
Loose tube nominal diameter 3,0 mm
Outer jacket nominal thickness 1,1 mm
Cable nominal outer diameter 5,8 mm
Cable informative weight 41 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
All-dielectric Duct Cables UX1EF
27
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 300 N (long term) 1000 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11
Fire performance
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Dca-s2,d1,a1
Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
UX1EF Ø 5,8 Dca-s2,d1,a1
16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B
20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B
24 01.24.M3.B R848290 01.24.M5.B R848352 R848353
Order code e.g.: UX1EF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Central Loose Tube Cables
28
R&M generates added value. Connectivity that matters.Cable construction code DIN code
OT1GL xx.yy.zz.c A-DQ(BN)2Y wbg
1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. LDPE UV stable outer jacket
Cable general description
Max. 12 fiber uni-tube non-metallic cable with improved level of rodent protection for outdoor duct installation.
Construction and dimensions
Loose tube nominal diameter 2,8 mm
Outer jacket nominal thickness 1,1 mm
Cable nominal outer diameter 6,5 mm
Cable informative weight 37 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable LDPE
Jacket colour Black
Sheath marking Ink-Jet, white
Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
All-dielectric Duct Cables with improved rodent protection
OT1GL
29
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 600 N (long term) 1800 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-25°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-20°C ÷ 70°C-25°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
OT1GL Ø 6,5
4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B
6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B
8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B
12 01.12.M3.B 01.12.M4.B 01.12.M5.B R848354 01.12.S7.B
Order code e.g.: OT1GL 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Central Loose Tube Cables
30
R&M generates added value. Connectivity that matters.Cable construction code DIN code
OX1GL xx.yy.zz.c A-DQ(BN)2Y wbg
1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. LDPE UV stable outer jacket
Cable general description
Max. 24 fiber uni-tube non-metallic cable with improved level of rodent protection for outdoor duct installation.
Construction and dimensions
Loose tube nominal diameter 3,5 mm
Outer jacket nominal thickness 1,2 mm
Cable nominal outer diameter 7,4 mm
Cable informative weight 50 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable LDPE
Jacket colour Black
Sheath marking Ink-Jet, white
Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
All-dielectric Duct Cables with improved rodent protection
OX1GL
31
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 600 N (long term) 2000 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-25°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-20°C ÷ 70°C-25°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
OX1GL Ø 7,4
16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B
20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B
24 01.24.M3.B 01.24.M4.B 01.24.M5.B R848355 01.24.S7.B
Order code e.g.: OX1GL 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Central Loose Tube Cables
32
R&M generates added value. Connectivity that matters.Cable construction code DIN code
UT1GF xx.yy.zz.c J/A-DQ(BN)H wbg
1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. FRLSZH UV stable outer jacket
Cable general description
Max. 12 fiber uni-tube non-metallic cable with improved rodent protection for indoor or outdoor duct installation.
Construction and dimensions
Loose tube nominal diameter 2,3 mm
Outer jacket nominal thickness 1,1 mm
Cable nominal outer diameter 6,2 mm
Cable informative weight 45 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
All-dielectric Duct Cables with improved rodent protection
UT1GF
33
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 600 N (long term) 1800 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11
Fire performance
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Dca-s2,d1,a1
Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
UT1GF Ø 6,2 Dca-s2,d1,a1
4 01.04.M3.B R848356 01.04.M5.B 01.04.S2.B 01.04.S7.B
6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B
8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B
12 01.12.M3.B R848357 01.12.M5.B R848358 01.12.S7.B
Order code e.g.: UT1GF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Central Loose Tube Cables
34
R&M generates added value. Connectivity that matters.Cable construction code DIN code
UX1GF xx.yy.zz.c J/A-DQ(BN)H wbg
1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. FRLSZH UV stable outer jacket
Cable general description
Max. 24 fiber uni-tube non-metallic cable with improved rodent protection for indoor or outdoor duct installation.
Construction and dimensions
Loose tube nominal diameter 3,0 mm
Outer jacket nominal thickness 1,2 mm
Cable nominal outer diameter 7,2 mm
Cable informative weight 58 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
All-dielectric Duct Cables with improved rodent protection
UX1GF
35
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 800 N (long term) 2000 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11
Fire performance
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Dca-s2,d1,a1
Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
UX1GF Ø 7,2 Dca-s2,d1,a1
16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B
20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B
24 01.24.M3.B 01.24.M4.B 01.24.M5.B R848359 01.24.S7.B
Order code e.g.: UX1GF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Central Loose Tube Cables
36
R&M generates added value. Connectivity that matters.Cable construction code DIN code
OX1ELWH xx.yy.zz.c A-DQ(ZN)2YB2Y wbg (R 0,63vzk)
1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. LDPE UV stable inner jacket4. Zn galvanized steel wire armour fixed by PET tape5. Rip-cord6. HDPE UV stable outer jacket
Cable general description
Max. 24 fiber uni-tube steel wire armoured cable with two jackets for outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.
Construction and dimensions
Loose tube nominal diameter 3,1 mm
Inner jacket nominal thickness 1,1 mm
Steel wire nominal diameter 0,63 mm
Outer jacket nominal thickness 1,3 mm
Cable nominal outer diameter 9,9 mm
Cable informative weight 150 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable HDPE
Jacket colour Black
Sheath marking Ink-Jet, white
Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Steel Wire Armoured Cables SWA
OX1ELWH
37
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 n.a. (long term) 4500 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 2000 N/100mm (long term)4000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-25°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-20°C ÷ 70°C-25°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
OX1EL Ø 9,9
4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B
6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B
8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B
12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B
16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B
20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B
24 01.24.M3.B 01.24.M4.B 01.24.M5.B R848360 01.24.S7.B
Order code e.g.: OX1ELWH 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Central Loose Tube Cables
38
R&M generates added value. Connectivity that matters.Cable construction code DIN code
UX1ELWF xx.yy.zz.c J/A-DQ(ZN)2YBH wbg (R 0,63vzk)
1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. LDPE UV stable inner jacket4. Zn galvanized steel wire armour fixed by PET tape5. Rip-cord6. FRLSZH UV stable outer jacket
Cable general description
Max. 24 fiber uni-tube steel wire armoured cable with two jackets for indoor or outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.
Construction and dimensions
Loose tube nominal diameter 3,0 mm
Inner jacket nominal thickness 1,1 mm
Steel wire nominal diameter 0,63 mm
Outer jacket nominal thickness 1,3 mm
Cable nominal outer diameter 9,9 mm
Cable informative weight 170 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Steel Wire Armoured Cables SWA
UX1ELWF
39
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
UX1ELWF Ø 9,9 Fca
4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B
6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B
8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B
12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B
16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B
20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B
24 01.24.M3.B 01.24.M4.B 01.24.M5.B R848361 01.24.S7.B
Order code e.g.: UX1ELWF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 n.a. (long term) 4500 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 2000 N/100mm (long term)4000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-30°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-20°C ÷ 70°C-30°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath
* EN 60794-3-10, EN 60794-3-11
Fire performance
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Fca
Cable expected lifetime / min. 30 years
Central Loose Tube Cables
40
R&M generates added value. Connectivity that matters.Cable construction code DIN code
UX1EFWF xx.yy.zz.c J/A-DQ(ZN)HBH wbg (R 0,63vzk)
1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. FRLSZH UV stable inner jacket4. Zn galvanized steel wire armour fixed by PET tape5. Rip-cord6. FRLSZH UV stable outer jacket
Cable general description
Max. 24 fiber uni-tube steel wire armoured cable with two jackets for indoor or outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.
Construction and dimensions
Loose tube nominal diameter 3,0 mm
Inner jacket nominal thickness 1,1 mm
Steel wire nominal diameter 0,63 mm
Outer jacket nominal thickness 1,3 mm
Cable nominal outer diameter 9,9 mm
Cable informative weight 180 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Steel Wire Armoured Cables SWA
UX1EFWF
41
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
UX1EFWF Ø 9,9 Dca-s2,d2,a1
4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B
6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B
8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B
12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B
16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B
20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B
24 01.24.M3.B 01.24.M4.B 01.24.M5.B R848362 01.24.S7.B
Order code e.g.: UX1EFWF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 n.a. (long term) 4500 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 2000 N/100mm (long term)4000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath
* EN 60794-3-10, EN 60794-3-11
Fire performance
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Dca-s2,d2,a1
Cable expected lifetime / min. 30 years
Central Loose Tube Cables
42
R&M generates added value. Connectivity that matters.Cable construction code DIN code
OX1ECH xx.yy.zz.c A-DQ(ZN)(SR)2Y wbg
1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. Rip-cord4. Corrugated steel tape armour5. HDPE UV stable outer jacket
Cable general description
Max. 24 fiber uni-tube steel wire armoured cable with two jackets for outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.
Construction and dimensions
Loose tube nominal diameter 3,0 mm
Inner jacket nominal thickness 1,2 mm
Cable nominal outer diameter 7,7 mm
Cable informative weight 70 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable LDPE
Jacket colour Black
Sheath marking Ink-Jet, white
Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Corrugated Steel Tape Armoured Cables CSTA
OX1ECH
43
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 500 N (long term)1500 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-30°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-20°C ÷ 70°C-30°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
OX1ECH Ø 7,7
4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B
6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B
8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B
12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B
16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B
20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B
24 01.24.M3.B 01.24.M4.B 01.24.M5.B R851112 01.24.S7.B
Order code e.g.: OX1ECH 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Central Loose Tube Cables
44
R&M generates added value. Connectivity that matters.Cable construction code DIN code
UX1ECF xx.yy.zz.c J/A-DQ(ZN)(SR)H wbg
1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. Rip-cord4. Corrugated steel tape armour5. FRLSZH UV stable outer jacket
Cable general description
Max. 24 fiber uni-tube corrugated steel tape armoured cable for indoor or outdoor duct or direct buried installation. This cable construction offers good mechanical and full rodent protection.
Construction and dimensions
Loose tube nominal diameter 3,0 mm
Inner jacket nominal thickness 1,2 mm
Cable nominal outer diameter 7,7 mm
Cable informative weight 84 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Corrugated Steel Tape Armoured Cables CSTA
UX1ECF
45
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
UX1ECF Ø 7,7 Dca-s2,d2,a1
4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B
6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B
8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B
12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B
16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B
20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B
24 01.24.M3.B 01.24.M4.B 01.24.M5.B R848363 01.24.S7.B
Order code e.g.: UX1ECF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 500 N (long term)1500 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11
Fire performance
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Dca-s2,d2,a1
Cable expected lifetime / min. 30 years
Central Loose Tube Cables
46
R&M generates added value. Connectivity that matters.Cable construction code DIN code
OX1ELCH xx.yy.zz.c A-DQ(ZN)2Y(SR)2Y wbg
1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. LDPE UV stable inner jacket4. Rip-cord5. Corrugated steel tape armour6. HDPE UV stable outer jacket
Cable general description
Max. 24 fiber uni-tube corrugated steel tape armoured cable with two jackets for outdoor duct or direct buriedinstallation. This cable construction offers excellent mechanical and full rodent protection.
Construction and dimensions
Loose tube nominal diameter 3,1 mm
Inner jacket nominal thickness 0,8 mm
Outer jacket nominal thickness 1,2 mm
Cable nominal outer diameter 10,0 mm
Cable informative weight 100 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable LDPE
Jacket colour Black
Sheath marking Ink-Jet, white
Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Corrugated Steel Tape Armoured Cables CSTA
OX1ELCH
47
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 500 N (long term)1500 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-25°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-20°C ÷ 70°C-25°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath
* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
OX1ELCH Ø 10,0
4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B
6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B
8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B
12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B
16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B
20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B
24 01.24.M3.B 01.24.M4.B 01.24.M5.B R848364 01.24.S7.B
Order code e.g.: OX1ELCH 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Central Loose Tube Cables
48
R&M generates added value. Connectivity that matters.Cable construction code DIN code
UX1ELCF xx.yy.zz.c J/A-DQ(ZN)2Y(SR)H wbg
1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. LDPE UV stable inner jacket4. Rip-cord5. Corrugated steel tape armour6. FRLSZH UV stable outer jacket
Cable general description
Max. 24 fiber uni-tube corrugated steel tape armoured cable with two jackets for indoor or outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.
Construction and dimensions
Loose tube nominal diameter 3,0 mm
Inner jacket nominal thickness 0,8 mm
Outer jacket nominal thickness 1,2 mm
Cable nominal outer diameter 10,0 mm
Cable informative weight 115 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Corrugated Steel Tape Armoured Cables CSTA
UX1ELCF
49
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
UX1ELCF Ø 10,0 Fca
4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B
6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B
8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B
12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B
16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B
20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B
24 01.24.M3.B 01.24.M4.B 01.24.M5.B R848365 01.24.S7.B
Order code e.g.: UX1ELCF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 500 N (long term)1500 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-30°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-20°C ÷ 70°C-30°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath
* EN 60794-3-10, EN 60794-3-11
Fire performance
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Fca
Cable expected lifetime / min. 30 years
Central Loose Tube Cables
50
R&M generates added value. Connectivity that matters.Cable construction code DIN code
UX1EFCF xx.yy.zz.c J/A-DQ(ZN)H(SR)H wbg
1. Gel filled PBT loose tube with optical fibers2. Water-blocking e-glass yarn3. FRLSZH UV stable inner jacket4. Rip-cord5. Corrugated steel tape armour6. FRLSZH UV stable outer jacket
Cable general description
Max. 24 fiber uni-tube corrugated steel tape armoured cable with two jackets for indoor or outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.
Construction and dimensions
Loose tube nominal diameter 3,0 mm
Inner jacket nominal thickness 0,8 mm
Outer jacket nominal thickness 1,2 mm
Cable nominal outer diameter 10,0 mm
Cable informative weight 125 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Corrugated Steel Tape Armoured Cables CSTA
UX1EFCF
51
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
UX1EFCF Ø 10,0 Cca-s1,d0,a1
4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B
6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B
8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B
12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B
16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B
20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B
24 01.24.M3.B 01.24.M4.B 01.24.M5.B R849571 01.24.S7.B
Order code e.g.: UX1EFCF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 500 N (long term)1500 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath
* EN 60794-3-10, EN 60794-3-11
Fire performance
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Cca-s1,d0,a1
Cable expected lifetime / min. 30 years
Central Loose Tube Cables
52
R&M generates added value. Connectivity that matters.Cable construction code DIN code
OX1PH xx.yy.zz.c A-DQ(ZN)B2Y (FRP 1,0)
1. Gel filled PBT loose tube with optical fibers2. Water swellable yarn3. Armour of FRP rods fixed by PET tape4. Rip-cord5. HDPE UV stable outer jacket
Cable general description
Max. 24 fiber uni-tube corrugated steel tape armoured cable with two jackets for outdoor duct or direct buriedinstallation. This cable construction offers excellent mechanical and full rodent protection.
Construction and dimensions
Loose tube nominal diameter 3,0 mm
Outer jacket nominal thickness 1,2 mm
Cable nominal outer diameter 7,4 mm
Cable informative weight 52 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable LDPE
Jacket colour Black
Sheath marking Ink-Jet, white
Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Fiber Reinforced Plastic Rod Armoured Cables FRPA
OX1PH
53
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 800 N (long term) 2500 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 1500 N/100mm (long term)3000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-30°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-20°C ÷ 70°C-30°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
OX1PH Ø 7,4
4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B
6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B
8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B
12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B
16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B
20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B
24 01.24.M3.B 01.24.M4.B 01.24.M5.B R849572 01.24.S7.B
Order code e.g.: OX1PH 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Central Loose Tube Cables
54
R&M generates added value. Connectivity that matters.Cable construction code DIN code
UX1PF xx.yy.zz.c J/A-DQ(ZN)BH (FRP 1,0)
1. Gel filled PBT loose tube with optical fibers2. Water swellable yarn3. Armour of FRP rods4. Rip-cord5. FRLSZH UV stable outer jacket
Cable general description
Max. 24 fiber uni-tube non-metallic FRP rods armoured cable for indoor or outdoor duct or direct buried installation. This cable construction offers good mechanical and full rodent protection.
Construction and dimensions
Loose tube nominal diameter 3,0 mm
Outer jacket nominal thickness 1,2 mm
Cable nominal outer diameter 7,4 mm
Cable informative weight 65 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Fiber Reinforced Plastic Rod Armoured Cables FRPA
UX1PF
55
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
UX1PF Ø 7,4 Fca
4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B
6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B
8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B
12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B
16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B
20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B
24 01.24.M3.B 01.24.M4.B 01.24.M5.B R849573 01.24.S7.B
Order code e.g.: UX1PF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 800 N (long term) 2500 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 1500 N/100mm (long term)3000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath
* EN 60794-3-10, EN 60794-3-11
Fire performance
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Fca
Cable expected lifetime / min. 30 years
Central Loose Tube Cables
56
R&M generates added value. Connectivity that matters.Cable construction code DIN code
QT1GF xx.yy.zz.c J/A-DQ(BN)H wbg fr
1. Gel filled PBT loose tube with optical fibers2. Fire-resistant tape3. Water-blocking e-glass yarn4. FRLSZH UV stable outer jacket
Cable general description
Max. 12 fiber uni-tube non-metallic fire-resistant cable for indoor or outdoor duct installation. This cable construction offers improved rodent protection.
Construction and dimensions
Loose tube nominal diameter 2,3 mm
Outer jacket nominal thickness 1,3 mm
Cable nominal outer diameter 7,0 mm
Cable informative weight 58 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Fire Resistant Cables All-dielectric Non-armoured
QT1GF
57
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 800 N (long term) 2000 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-30°C ÷ 70°C -35°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11
Fire performance
Fire resistance EN 60331-25 (180 min at 750°C) Pass
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Dca-s1,d1,a1
Cable expected lifetime / min. 30 years
Central Loose Tube Cables
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
QT1GF Ø 7,0 Dca-s1,d1,a1
4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B
6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B
8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B
12 01.12.M3.B 01.12.M4.B 01.12.M5.B R849574 01.12.S7.B
Order code e.g.: UT1EF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
58
R&M generates added value. Connectivity that matters.Cable construction code DIN code
QX1GF xx.yy.zz.c J/A-DQ(BN)H wbg fr
1. Gel filled PBT loose tube with optical fibers2. Fire-resistant tape3. Water-blocking e-glass yarn4. FRLSZH UV stable outer jacket
Cable general description
Max. 24 fiber uni-tube non-metallic fire-resistant cable for indoor or outdoor duct installation. This cable construction offers improved rodent protection.
Construction and dimensions
Loose tube nominal diameter 3,0 mm
Outer jacket nominal thickness 1,3 mm
Cable nominal outer diameter 7,8 mm
Cable informative weight 68 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Fire Resistant Cables All-dielectric Non-armoured
QX1GF
59
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 800 N (long term) 2000 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11
Fire performance
Fire resistance EN 60331-25 (180 min at 750°C) Pass
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Dca-s2,d1,a1
Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
QX1GF Ø 7,8 Dca-s2,d1,a1
16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B
20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B
24 01.24.M3.B 01.24.M4.B 01.24.M5.B R849575 01.24.S7.B
Order code e.g.: QX1GF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Central Loose Tube Cables
60
R&M generates added value. Connectivity that matters.Cable construction code DIN code
QX1ECF xx.yy.zz.c J/A-DQ(ZN)(SR)H wbg fr
1. Gel filled PBT loose tube with optical fibers2. Fire-resistant tape3. Water-blocking e-glass yarn4. Rip-cord5. Corrugated steel tape armour6. FRLSZH UV stable outer jacket
Cable general description
Max. 24 fiber uni-tube fire-resistant corrugated steel tape armoured cable for indoor or outdoor duct or direct buried installation. This cable construction offers good mechanical and full rodent protection.
Construction and dimensions
Loose tube nominal diameter 3,0 mm
Outer jacket nominal thickness 1,3 mm
Cable nominal outer diameter 8,0 mm
Cable informative weight 90 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Fire Resistant Cables Corrugated Steel Tape Armoured
QX1ECF
61
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 500 N (long term) 1500 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11
Fire performance
Fire resistance EN 60331-25 (180 min at 750°C) Pass
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Fca
Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
QX1ECF Ø 8,0 Fca
4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B
6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B
8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B
12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B
16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B
20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B
24 01.24.M3.B 01.24.M4.B 01.24.M5.B R849576 01.24.S7.B
Order code e.g.: QX1ECF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Central Loose Tube Cables
62
R&M generates added value. Connectivity that matters.Cable construction code DIN code
QX1EFCF xx.yy.zz.c J/A-DQ(ZN)H(SR)H wbg fr
1. Gel filled PBT loose tube with optical fibers2. Fire-resistant tape3. Water-blocking e-glass yarn4. FRLSZH UV stable inner jacket5. Rip-cord6. Corrugated steel tape armour7. FRLSZH UV stable outer jacket
Cable general description
Max. 24 fiber uni-tube fire-resistant corrugated steel tape armoured cable with two jackets for indoor or outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.
Construction and dimensions
Loose tube nominal diameter 3,0 mm
Inner jacket nominal thickness 1,0 mm
Outer jacket nominal thickness 1,2 mm
Cable nominal outer diameter 11,0 mm
Cable informative weight 150 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Fire Resistant Cables Corrugated Steel Tape Armoured
QX1EFCF
63
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 500 N (long term) 1500 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath
* EN 60794-3-10, EN 60794-3-11
Fire performance
Fire resistance EN 60331-25 (180 min at 750°C) Pass
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Fca
Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
QX1EFCF Ø 11,0 Fca
4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B
6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B
8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B
12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B
16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B
20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B
24 01.24.M3.B 01.24.M4.B 01.24.M5.B R849577 01.24.S7.B
Order code e.g.: QX1EFCF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Central Loose Tube Cables
64
R&M generates added value. Connectivity that matters.Cable construction code DIN code
QX1EFWF xx.yy.zz.c J/A-DQ(ZN)HBH wbg (R 0,63vzk) fr
1. Gel filled PBT loose tube with optical fibers2. Fire-resistant tape3. Water-blocking e-glass yarn4. FRLSZH UV stable inner jacket5. Zn galvanized steel wire armour fixed by PET tape6. Rip-cord7. FRLSZH UV stable outer jacket
Cable general description
Max. 24 fiber uni-tube fire-resistant steel wire armoured cable with two jackets for indoor or outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.
Construction and dimensions
Loose tube nominal diameter 3,0 mm
Inner jacket nominal thickness 1,0 mm
Steel wire nominal diameter 0,63 mm
Outer jacket nominal thickness 1,3 mm
Cable nominal outer diameter 10,1 mm
Cable informative weight 185 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Fire Resistant Cables Steel Wire Armoured Cables
QX1EFWF
65
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 n.a. (long term) 4500 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 2000 N/100mm (long term)4000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-20°C ÷ 70°C-35°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath
* EN 60794-3-10, EN 60794-3-11
Fire performance
Fire resistance EN 60331-25 (180 min at 750°C) Pass
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Fca
Circuit integrity maintenance of cable systems under fire conditions
ČSN 73 0895, DIN 4102-12 (< 0,3 dB/m*) P90-R
* ČSN EN 50582 - Procedure to assess the circuit integrity of optical fibers in a cable under resistance to fire testing determines the maximum increase in attenuation 1,0 dB/m
Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
QX1EFWF Ø 10,1 Fca
4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B
6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B
8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B
12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B
16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B
20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B
24 01.24.M3.B 01.24.M4.B 01.24.M5.B R849578 01.24.S7.B
Order code e.g.: QX1EFWF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Central Loose Tube Cables
66
R&M generates added value. Connectivity that matters.Cable construction code DIN code
QX1ELWF xx.yy.zz.c J/A-DQ(ZN)2YBH wbg (R 0,63vzk) fr
1. Gel filled PBT loose tube with optical fibers2. Fire-resistant tape3. Water-blocking e-glass yarn4. LDPE UV stable inner jacket5. Zn galvanized steel wire armour fixed by PET tape6. Rip-cord7. FRLSZH UV stable outer jacket
Cable general description
Max. 24 fiber uni-tube fire-resistant steel wire armoured cable with two jackets for indoor or outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.
Construction and dimensions
Loose tube nominal diameter 3,1 mm
Inner jacket nominal thickness 1,0 mm
Steel wire nominal diameter 0,63 mm
Outer jacket nominal thickness 1,3 mm
Cable nominal outer diameter 10,1 mm
Cable informative weight 185 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Fire Resistant Cables Steel Wire Armoured Cables
QX1ELWF
67
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 n.a. (long term) 4500 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 2000 N/100mm (long term)4000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C-25°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-20°C ÷ 70°C-25°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath
* EN 60794-3-10, EN 60794-3-11
Fire performance
Fire resistance EN 60331-25 (180 min at 750°C) Pass
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Fca
Cable expected lifetime / min. 30 years
Central Loose Tube Cables
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
QX1ELWF Ø 10,1 Fca
4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B
6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B
8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B
12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B
16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B
20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B
24 01.24.M3.B 01.24.M4.B 01.24.M5.B R849579 01.24.S7.B
Order code e.g.: QX1ELWF 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
68
R&M generates added value. Connectivity that matters.Cable construction code DIN code
QX1EFWFc xx.yy.zz.c J/A-DQ(ZN)HBHx wbg (R 0,63vzk) fr
1. Gel filled PBT loose tube with optical fibers2. Fire-resistant tape3. Water-blocking e-glass yarn4. LDPE UV stable inner jacket5. Zn galvanized steel wire armour fixed by PET tape6. Rip-cord7. XL-FRLSZH UV stable outer jacket
Cable general description
Max. 24 fiber uni-tube fire-resistant steel wire armoured cable with two jackets for indoor or outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.
Construction and dimensions
Loose tube nominal diameter 3,1 mm
Inner jacket nominal thickness 1,0 mm
Steel wire nominal diameter 0,63 mm
Outer jacket nominal thickness 1,3 mm
Cable nominal outer diameter 10,1 mm
Cable informative weight 185 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable Cross-Linked FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304)1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink13.-24.: red, green, blue, yellow, white, grey, brown, violet, turquoise, natural, orange, pink (ring-marked)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Fire Resistant Cables Steel Wire Armoured Cables
QX1EFWFc
69
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 n.a. (long term) 4500 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 2000 N/100mm (long term)4000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -30°C ÷ 70°C-35°C ÷ 70°C
Δα ≤ 0,05 dBΔα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-30°C ÷ 70°C-35°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath
* EN 60794-3-10, EN 60794-3-11
Fire performance
Fire resistance EN 60331-25 (180 min at 750°C) Pass
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Fca
Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 OM5 G652.D G657.A1
QX1EFWFc Ø 10,1 Fca
4 01.04.M3.B 01.04.M4.B 01.04.M5.B 01.04.S2.B 01.04.S7.B
6 01.06.M3.B 01.06.M4.B 01.06.M5.B 01.06.S2.B 01.06.S7.B
8 01.08.M3.B 01.08.M4.B 01.08.M5.B 01.08.S2.B 01.08.S7.B
12 01.12.M3.B 01.12.M4.B 01.12.M5.B 01.12.S2.B 01.12.S7.B
16 01.16.M3.B 01.16.M4.B 01.16.M5.B 01.16.S2.B 01.16.S7.B
20 01.20.M3.B 01.20.M4.B 01.20.M5.B 01.20.S2.B 01.20.S7.B
24 01.24.M3.B 01.24.M4.B 01.24.M5.B R851111 01.24.S7.B
Order code e.g.: QX1EFWFc 01.04.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Central Loose Tube Cables
70
R&M generates added value. Connectivity that matters.Multi Loose Tube Cables. MLT.
72
R&M generates added value. Connectivity that matters.
Multi Loose Tube Cables Overview
Microcables
MT6x1,5AH
76 MT.x1,5AH xx.yy.zz.c outdoor
72 fibers 6
1.55MT8x1,5AH 96 fibers 8
MT3x1,5AH 144 fibers 12
MT9x1,5AH 216 fibers 6 + 12 (18)
MT6x1,5AF
78 MT.x1,5AF xx.yy.zz.c indoor/outdoor
72 fibers 6
1.55MT8x1,5AF 96 fibers 8
MT3x1,5AF 144 fibers 12
MT3x1,5AHs 80 MT3x1,5AHs xx.yy.zz.c outdoor 144 fibers 12 1.55
All-dielectric Duct Cables
OT6x1,7H
82 OT.x1,7H xx.yy.zz.c outdoor
72 fibers 6
1.7 OT8x1,7H 96 fibers 8
OT3x1,7H 144 fibers 12
OT9x1,7H 216 fibers 6 + 12 (18)
UT6x1,7F
84 UT.x1,7F xx.yy.zz.c indoor/outdoor
72 fibers 6
1.7 UT8x1,7F 96 fibers 8
UT3x1,7F 144 fibers 12
UT9x1,7F 216 fibers 6 + 12 (18)
OT6x1,5AH
86 OT.x2,3EH xx.yy.zz.c outdoor
72 fibers 6
2.3 OT8x1,5AH 96 fibers 8
OT3x1,5AH 144 fibers 12
OT9x1,5AH 216 fibers 6 + 12 (18)
UT6x2,3EF
88 UT.x2,3EF xx.yy.zz.c indoor/outdoor
72 fibers 6
2.3 UT8x2,3EF 96 fibers 8
UT3x2,3EF 144 fibers 12
UT9x2,3EF 216 fibers 6 + 12 (18)
All-dielectric Duct Cables with improved rodent protection
OT6x1,7GH
90 OT.x1,7GH xx.yy.zz.c outdoor
72 fibers 6
1.7 OT8x1,7GH 96 fibers 8
OT3x1,7GH 144 fibers 12
OT9x1,7GH 216 fibers 6 + 12 (18)
UT6x1,7GF
92 UT.x1,7GF xx.yy.zz.c indoor/outdoor
72 fibers 6
1.7 UT8x1,7GF 96 fibers 8
UT3x1,7GF 144 fibers 12
UT9x1,7GF 216 fibers 6 + 12 (18)
OT6x2,3GH
94 OT.x2,3GH xx.yy.zz.c outdoor
72 fibers 6
2.3 OT8x2,3GH 96 fibers 8
OT3x2,3GH 144 fibers 12
OT9x2,3GH 216 fibers 6 + 12 (18)
UT6x2,3GF
96 UT.x2,3GF xx.yy.zz.c indoor/outdoor
72 fibers 6
2.3 UT8x2,3GF 96 fibers 8
UT3x2,3GF 144 fibers 12
UT9x2,3GF 216 fibers 6 + 12 (18)
Cable type Construction Page Construction code ApplicationFiber count[fibers]
Loose tubes count
Loose tube nominal Ø [mm]
Jacket material
Euro classification to CPR
Nominal cable Ø [mm]
Cable weight [kg/km]
Tensile performance [N]
Crush [N/100mm]
Temperatur range in operation
Fire resistance – EN 60331-25
73
Microcables
MT6x1,5AH
76 MT.x1,5AH xx.yy.zz.c outdoor
72 fibers 6
1.55MT8x1,5AH 96 fibers 8
MT3x1,5AH 144 fibers 12
MT9x1,5AH 216 fibers 6 + 12 (18)
MT6x1,5AF
78 MT.x1,5AF xx.yy.zz.c indoor/outdoor
72 fibers 6
1.55MT8x1,5AF 96 fibers 8
MT3x1,5AF 144 fibers 12
MT3x1,5AHs 80 MT3x1,5AHs xx.yy.zz.c outdoor 144 fibers 12 1.55
All-dielectric Duct Cables
OT6x1,7H
82 OT.x1,7H xx.yy.zz.c outdoor
72 fibers 6
1.7 OT8x1,7H 96 fibers 8
OT3x1,7H 144 fibers 12
OT9x1,7H 216 fibers 6 + 12 (18)
UT6x1,7F
84 UT.x1,7F xx.yy.zz.c indoor/outdoor
72 fibers 6
1.7 UT8x1,7F 96 fibers 8
UT3x1,7F 144 fibers 12
UT9x1,7F 216 fibers 6 + 12 (18)
OT6x1,5AH
86 OT.x2,3EH xx.yy.zz.c outdoor
72 fibers 6
2.3 OT8x1,5AH 96 fibers 8
OT3x1,5AH 144 fibers 12
OT9x1,5AH 216 fibers 6 + 12 (18)
UT6x2,3EF
88 UT.x2,3EF xx.yy.zz.c indoor/outdoor
72 fibers 6
2.3 UT8x2,3EF 96 fibers 8
UT3x2,3EF 144 fibers 12
UT9x2,3EF 216 fibers 6 + 12 (18)
All-dielectric Duct Cables with improved rodent protection
OT6x1,7GH
90 OT.x1,7GH xx.yy.zz.c outdoor
72 fibers 6
1.7 OT8x1,7GH 96 fibers 8
OT3x1,7GH 144 fibers 12
OT9x1,7GH 216 fibers 6 + 12 (18)
UT6x1,7GF
92 UT.x1,7GF xx.yy.zz.c indoor/outdoor
72 fibers 6
1.7 UT8x1,7GF 96 fibers 8
UT3x1,7GF 144 fibers 12
UT9x1,7GF 216 fibers 6 + 12 (18)
OT6x2,3GH
94 OT.x2,3GH xx.yy.zz.c outdoor
72 fibers 6
2.3 OT8x2,3GH 96 fibers 8
OT3x2,3GH 144 fibers 12
OT9x2,3GH 216 fibers 6 + 12 (18)
UT6x2,3GF
96 UT.x2,3GF xx.yy.zz.c indoor/outdoor
72 fibers 6
2.3 UT8x2,3GF 96 fibers 8
UT3x2,3GF 144 fibers 12
UT9x2,3GF 216 fibers 6 + 12 (18)
HDPE
5.7 30.0 600
1'000 -40°C to 70°C
6.6 40.0 1'200
8.6 64.0 1'200
8.9 64.0 800
FRLSZH Fca
6.8 50.0 600
1'000 -40°C to 70°C
7.6 64.0 1'200
9.6 95.0 1'400
HDPE 7.6 44.0 400 500 -40°C to 70°C
HDPE
7.5 55.0
2'000 2'000 -40°C to 70°C
9.5 70.0
11.7 105.0
11.8 110.0
FRLSZH Eca
7.5 70.0
2'000 2'000 -40°C to 70°C
9.5 90.0
11.7 130.0
11.8 135.0
HDPE
10.0 80.0 2'000
2'000 -40°C to 70°C
11.4 110.0 2'700
14.2 170.0 3'000
14.6 170.0 3'000
FRLSZH Eca
10.0 100.0 2'000
2'000 -40°C to 70°C
11.4 130.0 2'700
14.2 190.0 3'000
14.6 195.0 3'000
HDPE
9.0 70.0 2'700
2'000 -40°C to 70°C
10.0 90.0 4'000
12.2 130.0 4'500
12.7 135.0 4'500
FRLSZH Eca
9.0 90.0 2'700
2'000 -40°C to 70°C
10.0 115.0 4'000
12.2 155.0 4'500
12.7 160.0 4'500
HDPE
11.0 100.0 3'500
2'000 -40°C to 70°C
12.5 130.0 4'000
15.3 190.0 5'000
15.7 195.0 5'000
FRLSZH Eca
11.0 120.0 3'500
2'000 -40°C to 70°C
12.5 150.0 4'000
15.3 220.0 5'000
15.7 230.0 5'000
Cable type Construction Page Construction code ApplicationFiber count[fibers]
Loose tubes count
Loose tube nominal Ø [mm]
Jacket material
Euro classification to CPR
Nominal cable Ø [mm]
Cable weight [kg/km]
Tensile performance [N]
Crush [N/100mm]
Temperatur range in operation
Fire resistance – EN 60331-25
74
R&M generates added value. Connectivity that matters.
Steel Wire Armoured Cables – SWA
OT6x2,3LWH
98 OT.x2,3LWH xx.yy.zz.c outdoor
72 fibers 6
2.3 OT8x2,3LWH 96 fibers 8
OT3x2,3LWH 144 fibers 12
UT6x2,3FWF
100 UT.x2,3FWF xx.yy.zz.c indoor/outdoor
72 fibers 6
2.3 UT8x2,3FWF 96 fibers 8
UT3x2,3FWF 144 fibers 12
Corrugated Steel Tape Armoured Cables – CSTA
OT6x1,7ECH
102 OT.x1,7ECH xx.yy.zz.c outdoor
72 fibers 6
1.7 OT8x1,7ECH 96 fibers 8
OT3x1,7ECH 144 fibers 12
OT9x1,7ECH 216 fibers 6 + 12 (18)
UT6x1,7ECF
104 UT.x1,7ECF xx.yy.zz.c indoor/outdoor
72 fibers 6
1.7 UT8x1,7ECF 96 fibers 8
UT3x1,7ECF 144 fibers 12
UT9x1,7ECF 216 fibers 6 + 12 (18)
OT6x1,7ELCH
106 OT.x1,7ELCH xx.yy.zz.c outdoor
72 fibers 6
1.7 OT8x1,7ELCH 96 fibers 8
OT3x1,7ELCH 144 fibers 12
OT9x1,7ELCH 216 fibers 6 + 12 (18)
UT6x1,7EFCF
108 UT.x1,7EFCF xx.yy.zz.c indoor/outdoor
72 fibers 6
1.7UT8x1,7EFCF 96 fibers 8
UT3x1,7EFCF 144 fibers 12
UT9x1,7EFCF 216 fibers 6 + 12 (18)
Fire Resistant Cables – All-dielectric Non-armoured
QT6x2,3GF
110 QT.x2,3GF xx.yy.zz.c indoor/outdoor
72 fibers 6
2.3 QT8x2,3GF 96 fibers 8
QT3x2,3GF 144 fibers 12
Fire Resistant Cables – Corrugated Steel Tape Armoured
QT6x2,3EFCF
112 QT.x2,3EFCF xx.yy.zz.c indoor/outdoor
72 fibers 6
2.3 QT8x2,3EFCF 96 fibers 8
QT3x2,3EFCF 144 fibers 12
Fire Resistant Cables – Steel Wire Armoured Cables
QT6x2,3FWF
114 QT.x2,3FWF xx.yy.zz.c indoor/outdoor
72 fibers 6
2.3 QT8x2,3FWF 96 fibers 8
QT3x2,3FWF 144 fibers 12
Cable type Construction Page Construction code ApplicationFiber count[fibers]
Loose tubes count
Loose tube nominal Ø [mm]
Jacket material
Euro classification to CPR
Nominal cable Ø [mm]
Cable weight [kg/km]
Tensile performance [N]
Crush [N/100mm]
Temperatur range in operation
Fire resistance – EN 60331-25
Multi Loose Tube Cables Overview
75
Steel Wire Armoured Cables – SWA
OT6x2,3LWH
98 OT.x2,3LWH xx.yy.zz.c outdoor
72 fibers 6
2.3 OT8x2,3LWH 96 fibers 8
OT3x2,3LWH 144 fibers 12
UT6x2,3FWF
100 UT.x2,3FWF xx.yy.zz.c indoor/outdoor
72 fibers 6
2.3 UT8x2,3FWF 96 fibers 8
UT3x2,3FWF 144 fibers 12
Corrugated Steel Tape Armoured Cables – CSTA
OT6x1,7ECH
102 OT.x1,7ECH xx.yy.zz.c outdoor
72 fibers 6
1.7 OT8x1,7ECH 96 fibers 8
OT3x1,7ECH 144 fibers 12
OT9x1,7ECH 216 fibers 6 + 12 (18)
UT6x1,7ECF
104 UT.x1,7ECF xx.yy.zz.c indoor/outdoor
72 fibers 6
1.7 UT8x1,7ECF 96 fibers 8
UT3x1,7ECF 144 fibers 12
UT9x1,7ECF 216 fibers 6 + 12 (18)
OT6x1,7ELCH
106 OT.x1,7ELCH xx.yy.zz.c outdoor
72 fibers 6
1.7 OT8x1,7ELCH 96 fibers 8
OT3x1,7ELCH 144 fibers 12
OT9x1,7ELCH 216 fibers 6 + 12 (18)
UT6x1,7EFCF
108 UT.x1,7EFCF xx.yy.zz.c indoor/outdoor
72 fibers 6
1.7UT8x1,7EFCF 96 fibers 8
UT3x1,7EFCF 144 fibers 12
UT9x1,7EFCF 216 fibers 6 + 12 (18)
Fire Resistant Cables – All-dielectric Non-armoured
QT6x2,3GF
110 QT.x2,3GF xx.yy.zz.c indoor/outdoor
72 fibers 6
2.3 QT8x2,3GF 96 fibers 8
QT3x2,3GF 144 fibers 12
Fire Resistant Cables – Corrugated Steel Tape Armoured
QT6x2,3EFCF
112 QT.x2,3EFCF xx.yy.zz.c indoor/outdoor
72 fibers 6
2.3 QT8x2,3EFCF 96 fibers 8
QT3x2,3EFCF 144 fibers 12
Fire Resistant Cables – Steel Wire Armoured Cables
QT6x2,3FWF
114 QT.x2,3FWF xx.yy.zz.c indoor/outdoor
72 fibers 6
2.3 QT8x2,3FWF 96 fibers 8
QT3x2,3FWF 144 fibers 12
HDPE
14.5 330.0 5'000
4'000 -40°C to 70°C 15.8 385.0 6'000
19.4 610.0 8'000
FRLSZH Fca
14.5 370.0 5'000
4'000 -40°C to 70°C 15.8 430.0 6'000
19.4 670.0 8'000
HDPE
11.0 115.0 2'500
5'000 -40°C to 70°C 12.0 140.0 4'000
14.0 185.0 4'000
14.0 185.0 3'500
FRLSZH Fca
11.0 135.0 2'500
5'000 -40°C to 70°C 12.0 165.0 4'000
14.0 210.0 4'000
14.0 210.0 3'500
HDPE
12.1 145.0 2'500
5'000 -40°C to 70°C 13.1 175.0 4'000
15.1 220.0 4'000
16.1 240.0 4'000
FRLSZH Fca
12.1 180.0 2'500
5'000 -40°C to 70°C 13.1 210.0 4'000
15.1 270.0 4'000
16.1 290.0 4'000
FRLSZH Fca
13.0 180.0 4'500
2'000 -40°C to 70°C 180 min at 750°C14.6 225.0 4'500
18.0 340.0 6'000
FRLSZH Fca
16.5 300.0 3'000
5'000 -40°C to 70°C 180 min at 750°C17.5 350.0 3'000
21.5 500.0 3'500
FRLSZH Fca
15.6 440.0 5'000
4'000 -40°C to 70°C 180 min at 750°C17.7 570.0 8'000
21.1 800.0 10'000
Cable type Construction Page Construction code ApplicationFiber count[fibers]
Loose tubes count
Loose tube nominal Ø [mm]
Jacket material
Euro classification to CPR
Nominal cable Ø [mm]
Cable weight [kg/km]
Tensile performance [N]
Crush [N/100mm]
Temperatur range in operation
Fire resistance – EN 60331-25
76
R&M generates added value. Connectivity that matters.Cable construction code DIN code
MT.x1,5AH xx.yy.zz.c A-DQ(ZN)2Y nx1,5
1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable aramid yarn5. Rip-cord6. HDPE UV stable outer jacket
Cable general description
Multi Loose Tube non-metallic micro-cable for outdoor installation to micro-tubes.
Construction and dimensions MT6x1,5AH MT8x1,5AH H MT3x1,5AH MT9x1,5AH
Max. fiber count (12 fibers/tube) 72 96 144 216
Loose-tubes count 6 8 12 18(6+12)-two layers
Loose tube nominal diameter (mm) 1,55 1,55 1,55 1,55
FRP/coat. CSM nominal thickness (mm) 1,7 2,5 2,5 / 4,5 1,7
Outer jacket nominal thickness (mm) 0,5 0,5 0,5 0,5
Cable nominal outer diameter (mm) 5,7 6,6 8,6 8,9
Cable informative weight (kg/km) 30 40 64 64
Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%
Outer jacket
Material UV stable HDPE
Jacket colour Black
Sheath marking Ink-Jet, white
Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
MicrocablesMT.x1,5AH
77
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1
MT6x.. MT8x.. MT3x.. MT9x..
Δα ≤ 0,05 dB after testshortterm
600 N
1200 N
1200 N
800N
Crush EN 60794-1-21:E3A 1000 N/100mm (short term) Δα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 5 Nm, 3 impacts, d = 20 mm, R = 300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R = 40 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Kink EN 60794-1-21:E10 d = 40 x cable diameter no damage
Bend no tension EN 60794-1-21:E11A R = 40 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB
Temperature range of use
-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-5-10 Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1
MT6x1,5AH Ø 5,7
4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B
4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B
6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B
6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B
6 x 12f 72f 06.12.M3.B 06.12.M4.B R851113 06.12.S7.B
MT8x1,5AH Ø 6,68 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B
8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B
MT3x1,5AH Ø 8,612 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B
12 x 12f 144f 12.12.M3.B 12.12.M4.B R851114 12.12.S7.B
MT9x1,5AH Ø 8,9
18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B
18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B
18 x 12f 216f 18.12.M3.B 18.12.M4.B 18.12.S2.B 18.12.S7.B
Order code e.g.: MT9x1,5AH 18.06.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Multi Loose Tube Cables
78
R&M generates added value. Connectivity that matters.Cable construction code DIN code
MT.x1,5AF xx.yy.zz.c J/A-DQ(ZN)H nx1,5
1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable aramid yarn5. Rip-cord6. FRLSZH UV stable outer jacket
Cable general description
Multi Loose Tube non-metallic micro-cable for indoor or outdoor installation to micro-tubes.
Construction and dimensions MT6x1,5AF MT8x1,5AF MT3x1,5AF
Max. fiber count (12 fibers/tube) 72 96 144
Loose-tubes count 6 8 12
Loose tube nominal diameter (mm) 1,55 1,55 1,55
FRP/coat. CSM nominal thickness (mm) 1,7 2,5 2,5 / 4,5
Outer jacket nominal thickness (mm) 1,0 1,0 1,0
Cable nominal outer diameter (mm) 6,8 7,6 9,6
Cable informative weight (kg/km) 50 64 95
Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Loose-tube colour coding 1.red, 2.green, rest of tubes white (fillers uncoloured or black)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
MicrocablesMT.x1,5AF
79
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1
MT6x.. MT8x.. MT3x..
Δα ≤ 0,05 dB after testshortterm
600 N
1200 N
1400 N
Crush EN 60794-1-21:E3A 1000 N/100mm (short term) Δα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 5 Nm, 3 impacts, d = 20 mm, R = 300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R = 40 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Kink EN 60794-1-21:E10 d = 40 x cable diameter no damage
Bend no tension EN 60794-1-21:E11A R = 40 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB
Temperature range of use
-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-5-10
Fire performance
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 50575, EN 13501-6 Pass
Euro classification to CPR Fca
Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1
MT6x1,5AF Ø 6,8
4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B
4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B
6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B
6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B
6 x 12f 72f 06.12.M3.B 06.12.M4.B R851115 06.12.S7.B
MT8x1,5AF Ø 7,68 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B
8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B
MT3x1,5AF Ø 9,612 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B
12 x 12f 144f 12.12.M3.B 12.12.M4.B R851116 12.12.S7.B
Order code e.g.: MT3x1,5AF 12.08.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Multi Loose Tube Cables
80
R&M generates added value. Connectivity that matters.Cable construction code DIN code
MT3x1,5AHs xx.yy.zz.c A-DQ(ZN)2Y 12x1,5
1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable aramid yarn5. Rip-cord6. HDPE UV stable outer jacket
Cable general description
Multi Loose Tube non-metallic micro-cable for outdoor installation to micro-tubes. The cable contains max. 144 fibers in 12 loose-tubes SZ stranded in two layers.
Construction and dimensions
Loose tube nominal diameter 1,55 mm
Outer jacket nominal thickness 0,5 mm
Cable nominal outer diameter 7,6 mm
Cable informative weight 44 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable HDPE
Jacket colour Black
Sheath marking Ink-Jet, white
Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
MicrocablesMT3x1,5AHs
81
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 400 N (short term) Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 500 N/100mm (short term) Δα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 1 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=40 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Kink EN 60794-1-21:E10 d = 40 x cable diameter no damage
Bend no tension EN 60794-1-21:E11A R = 40 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB
Temperature range of use
-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-5-10 Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1
MT3x1,5AHs Ø 7,6
12 x 6f 72f 12.06.M3.B 12.06.M4.B 12.06.S2.B 12.06.S7.B
12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B
12 x 12f 144f 12.12.M3.B 12.12.M4.B R851117 12.12.S7.B
Order code e.g.: MT3x1,5AHs 12.06.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Multi Loose Tube Cables
82
R&M generates added value. Connectivity that matters.Cable construction code DIN code
OT.x1,7H xx.yy.zz.c A-DQ(ZN)2Y nx1,7
1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable tape or e-glass yarn5. Rip-cord6. HDPE UV stable outer jacket
Cable general description
Multi Loose Tube non-metallic cable for outdoor duct installation.
Construction and dimensions OT6x1,7H OT8x1,7H OT3x1,7H OT9x1,7H
Max. fiber count (12 fibers/tube) 72 96 144 216
Loose-tubes count 6 8 12 18(6+12)-two layers
Loose tube nominal diameter (mm) 1,7 1,7 1,7 1,7
FRP/coat. CSM nominal thickness (mm) 1,7 2,8 2,8 / 5,0 1,7
Outer jacket nominal thickness (mm) 1,2 1,2 1,2 1,2
Cable nominal outer diameter (mm) 7,5 9,5 11,7 11,8
Cable informative weight (kg/km) 55 70 105 110
Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%
Outer jacket
Material UV stable HDPE
Jacket colour Black
Sheath marking Ink-Jet, white
Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
All-dielectric Duct Cables OT.x1,7H
83
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1
OT6x.. OT8x.. OT3x.. OT9x..
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
longterm
800 N
800 N
800 N
800N
shortterm
2000 N
2000 N
2000 N
2000N
Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB
Temperature range of use
-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1
OT6x1,7H Ø 7.5
4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B
4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B
6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B
6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B
6 x 12f 72f 06.12.M3.B 06.12.M4.B R851118 06.12.S7.B
OT8x1,7H Ø 9.5 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B
8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B
OT3x1,7H Ø 11.7 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B
12 x 12f 144f 12.12.M3.B 12.12.M4.B R851119 12.12.S7.B
OT9x1,7H Ø 11.8
18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B
18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B
18 x 12f 216f 18.12.M3.B 18.12.M4.B 18.12.S2.B 18.12.S7.B
Order code e.g.: OT6x1,7H 06.06.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Multi Loose Tube Cables
84
R&M generates added value. Connectivity that matters.Cable construction code DIN code
UT.x1,7F xx.yy.zz.c J/A-DQ(ZN)H nx1,7
1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable tape or yarn5. Rip-cord6. FRLSZH UV stable outer jacket
Cable general description
Multi Loose Tube non-metallic cable for indoor or outdoor duct installation.
Construction and dimensions UT6x1,7F UT8x1,7F UT3x1,7F UT9x1,7F
Max. fiber count (12 fibers/tube) 72 96 144 216
Loose-tubes count 6 8 12 18(6+12)-two layers
Loose tube nominal diameter (mm) 1,7 1,7 1,7 1,7
FRP/coat. CSM nominal thickness (mm) 1,7 2,8 2,8 / 5,0 1,7
Outer jacket nominal thickness (mm) 1,2 1,2 1,2 1,2
Cable nominal outer diameter (mm) 7,5 9,5 11,7 11,8
Cable informative weight (kg/km) 70 90 130 135
Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
All-dielectric Duct Cables UT.x1,7F
85
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1
UT6x.. UT8x.. UT3x.. UT9x..
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
longterm
800 N
800 N
800 N
800N
shortterm
2000 N
2000 N
2000 N
2000N
Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB
Temperature range of use
-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11
Fire performance
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Eca
Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1
UT6x1,7F Ø 7.5 Eca
4 x 8f 24f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B
4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B
6 x 6f 72f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B
6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B
6 x 12f 64f 06.12.M3.B 06.12.M4.B R851120 06.12.S7.B
UT8x1,7F Ø 9.5 Eca 8 x 8f 96f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B
8 x 12f 72f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B
UT3x1,7F Ø 11.7 Eca 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B
12 x 12f 144f 12.12.M3.B 12.12.M4.B R851121 12.12.S7.B
UT9x1,7F Ø 11.8 Eca
18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B
18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B
18 x 12f 216f 18.12.M3.B 18.12.M4.B 18.12.S2.B 18.12.S7.B
Order code e.g.: UT6x1,7F 06.06.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Multi Loose Tube Cables
86
R&M generates added value. Connectivity that matters.Cable construction code DIN code
OT.x2,3EH xx.yy.zz.c A-DQ(ZN)2Y wbg nx2,3
1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable e-glass yarn5. Rip-cord6. HDPE UV stable outer jacket
Cable general description
Multi Loose Tube non-metallic cable with standard rodent protection for outdoor duct installation.
Construction and dimensions OT6x2,3EH OT8x2,3EH OT3x2,3EH OT9x2,3EH
Max. fiber count (12 fibers/tube) 72 96 144 216
Loose-tubes count 6 8 12 18(6+12)-two layers
Loose tube nominal diameter (mm) 2,3 2,3 2,3 2,3
FRP/coat. CSM nominal thickness (mm) 2,5 2,5 / 3,9 2,8 / 6,7 2,5
Outer jacket nominal thickness (mm) 1,2 1,2 1,2 1,2
Cable nominal outer diameter (mm) 10,0 11,4 14,2 14,6
Cable informative weight (kg/km) 80 110 170 170
Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%
Outer jacket
Material UV stable HDPE
Jacket colour Black
Sheath marking Ink-Jet, white
Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
All-dielectric Duct Cables OT.x2,3EH
87
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1
OT6x.. OT8x.. OT3x.. OT9x..
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
longterm
800 N
900 N
1000 N
1000N
shortterm
2000 N
2700 N
3000 N
3000N
Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB
Temperature range of use
-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1
OT6x2,3EH Ø 10
4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B
4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B
6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B
6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B
6 x 12f 72f 06.12.M3.B 06.12.M4.B R851122 06.12.S7.B
OT8x2,3EH Ø 11.4 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B
8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B
OT3x2,3EH Ø 14.2 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B
12 x 12f 144f 12.12.M3.B 12.12.M4.B R851123 12.12.S7.B
OT9x2,3EH Ø 14.6
18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B
18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B
18 x 12f 216f 18.12.M3.B 18.12.M4.B 18.12.S2.B 18.12.S7.B
Order code e.g.: OT6x2,3EH 06.06.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Multi Loose Tube Cables
88
R&M generates added value. Connectivity that matters.Cable construction code DIN code
UT.x2,3EF xx.yy.zz.c J/A-DQ(ZN)H wbg nx2,3
1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable e-glass yarn5. Rip-cord6. FRLSZH UV stable outer jacket
Cable general description
Multi Loose Tube non-metallic cable with standard rodent protection for indoor or outdoor duct installation.
Construction and dimensions UT6x2,3EF UT8x2,3EF UT3x2,3EF UT9x2,3EF
Max. fiber count (12 fibers/tube) 72 96 144 216
Loose-tubes count 6 8 12 18(6+12)-two layers
Loose tube nominal diameter (mm) 2,3 2,3 2,3 2,3
FRP/coat. CSM nominal thickness (mm) 2,5 2,5 / 3,9 2,8 / 6,7 2,5
Outer jacket nominal thickness (mm) 1,2 1,2 1,2 1,2
Cable nominal outer diameter (mm) 10,0 11,4 14,2 14,6
Cable informative weight (kg/km) 100 130 190 195
Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
All-dielectric Duct Cables UT.x2,3EF
89
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1
UT6x.. UT8x.. UT3x.. UT9x..
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
longterm
800 N
900 N
1000 N
1000N
shortterm
2000 N
2700 N
3000 N
3000N
Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB
Temperature range of use
-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11
Fire performance
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Eca
Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1
UT6x2,3EF Ø 11,0 Eca
4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B
4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B
6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B
6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B
6 x 12f 72f 06.12.M3.B 06.12.M4.B R851124 06.12.S7.B
UT8x2,3EF Ø 12,5 Eca 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B
8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B
UT3x2,3EF Ø 15,3 Eca 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B
12 x 12f 144f 12.12.M3.B 12.12.M4.B R851125 12.12.S7.B
UT9x2,3EF Ø 15,7 Eca
18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B
18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B
18 x 12f 216f 18.12.M3.B 18.12.M4.B 18.12.S2.B 18.12.S7.B
Order code e.g.: UT6x2,3EF 06.06.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Multi Loose Tube Cables
90
R&M generates added value. Connectivity that matters.Cable construction code DIN code
OT.x1,7GH xx.yy.zz.c A-DQ(BN)2Y wbg nx1,7
1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable tape or e-glass yarn5. Rip-cord6. HDPE UV stable outer jacket
Cable general description
Multi Loose Tube non-metallic cable with improved rodent protection for outdoor duct installation.
Construction and dimensions OT6x1,7GH OT8x1,7GH OT3x1,7GH OT9x1,7GH
Max. fiber count (12 fibers/tube) 72 96 144 216
Loose-tubes count 6 8 12 18(6+12)-two layers
Loose tube nominal diameter (mm) 1,7 1,7 1,7 1,7
FRP/coat. CSM nominal thickness (mm) 1,7 2,8 2,5 / 5,0 1,7
Outer jacket nominal thickness (mm) 1,4 1,4 1,4 1,4
Cable nominal outer diameter (mm) 9,0 10,0 12,2 12,7
Cable informative weight (kg/km) 70 90 130 135
Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%
Outer jacket
Material UV stable HDPE
Jacket colour Black
Sheath marking Ink-Jet, white
Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
All-dielectric Duct Cables with improved rodent protection
OT.x1,7GH
91
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1
OT6x.. OT8x.. OT3x.. OT9x..
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
longterm
900 N
1200 N
1400 N
1400N
shortterm
2700 N
4000 N
4500 N
4500N
Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB
Temperature range of use
-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1
OT6x1,7GH Ø 9,0
4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B
4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B
6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B
6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B
6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B
OT8x1,7GH Ø 10,0 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B
8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B
OT3x1,7GH Ø 12,2 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B
12 x 12f 144f 12.12.M3.B 12.12.M4.B R851126 12.12.S7.B
OT9x1,7GH Ø 12,7
18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B
18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B
18 x 12f 216f 18.12.M3.B 18.12.M4.B 18.12.S2.B 18.12.S7.B
Order code e.g.: OT6x1,7GH 06.06.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Multi Loose Tube Cables
92
R&M generates added value. Connectivity that matters.Cable construction code DIN code
UT.x1,7GF xx.yy.zz.c J/A-DQ(BN)H wbg nx1,7
1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable e-glass yarn5. Rip-cord6. FRLSZH UV stable outer jacket
Cable general description
Multi Loose Tube non-metallic cable with improved rodent protection for indoor or outdoor duct installation.
Construction and dimensions OT6x1,7GF OT8x1,7GF OT3x1,7GF OT9x1,7GF
Max. fiber count (12 fibers/tube) 72 96 144 216
Loose-tubes count 6 8 12 18(6+12)-two layers
Loose tube nominal diameter (mm) 1,7 1,7 1,7 1,7
FRP/coat. CSM nominal thickness (mm) 1,7 2,8 2,5 / 5,0 1,7
Outer jacket nominal thickness (mm) 1,4 1,4 1,4 1,4
Cable nominal outer diameter (mm) 9,0 10,0 12,2 12,7
Cable informative weight (kg/km) 90 115 155 160
Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
All-dielectric Duct Cables with improved rodent protection
UT.x1,7GF
93
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1
UT6x.. UT8x.. UT3x.. UT9x..
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
longterm
900 N
1200 N
1400 N
1400N
shortterm
2700 N
4000 N
4500 N
4500N
Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB
Temperature range of use
-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11
Fire performance
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Eca
Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1
UT6x1,7GF Ø 9,0 Eca
4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B
4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B
6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B
6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B
6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B
UT8x1,7GF Ø 10,0 Eca 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B
8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B
UT3x1,7GF Ø 12,2 Eca 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B
12 x 12f 144f 12.12.M3.B 12.12.M4.B R851127 12.12.S7.B
UT9x1,7GF Ø 12,7 Eca
18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B
18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B
18 x 12f 216f 18.12.M3.B 18.12.M4.B 18.12.S2.B 18.12.S7.B
Order code e.g.: UT6x1,7GF 06.06.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Multi Loose Tube Cables
94
R&M generates added value. Connectivity that matters.Cable construction code DIN code
OT.x2,3GH xx.yy.zz.c A-DQ(BN)2Y wbg nx2,3
1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable e-glass yarn5. Rip-cord6. HDPE UV stable outer jacket
Cable general description
Multi Loose Tube non-metallic cable with improved rodent protection for outdoor duct installation.
Construction and dimensions OT6x2,3GH OT8x2,3GH OT3x2,3GH OT9x2,3GH
Max. fiber count (12 fibers/tube) 72 96 144 216
Loose-tubes count 6 8 12 18(6+12)-two layers
Loose tube nominal diameter (mm) 2,3 2,3 2,3 2,3
FRP/coat. CSM nominal thickness (mm) 2,5 2,5 / 3,9 2,8 / 6,7 2,5
Outer jacket nominal thickness (mm) 1,4 1,4 1,4 1,4
Cable nominal outer diameter (mm) 11,0 12,5 15,3 15,7
Cable informative weight (kg/km) 100 130 190 195
Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%
Outer jacket
Material UV stable HDPE
Jacket colour Black
Sheath marking Ink-Jet, white
Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
All-dielectric Duct Cables with improved rodent protection
OT.x2,3GH
95
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1
OT6x.. OT8x.. OT3x.. OT9x..
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
longterm
1100 N
1200 N
1500 N
1500N
shortterm
3500 N
4000 N
5000 N
5000N
Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB
Temperature range of use
-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1
OT6x2,3GH Ø 11,0
4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B
4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B
6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B
6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B
6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B
OT8x2,3GH Ø 12,5 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B
8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B
OT3x2,3GH Ø 15,3 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B
12 x 12f 144f 12.12.M3.B 12.12.M4.B R851128 12.12.S7.B
OT9x2,3GH Ø 15,7
18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B
18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B
18 x 12f 216f 18.12.M3.B 18.12.M4.B 18.12.S2.B 18.12.S7.B
Order code e.g.: OT6x2,3GH 06.06.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Multi Loose Tube Cables
96
R&M generates added value. Connectivity that matters.Cable construction code DIN code
UT.x2,3GF xx.yy.zz.c J/A-DQ(BN)H wbg nx2,3
1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable e-glass yarn5. Rip-cord6. FRLSZH UV stable outer jacket
Cable general description
Multi Loose Tube non-metallic cable with improved rodent protection for indoor or outdoor duct installation.
Construction and dimensions OT6x2,3GF OT8x2,3GF OT3x2,3GF OT9x2,3GF
Max. fiber count (12 fibers/tube) 72 96 144 216
Loose-tubes count 6 8 12 18(6+12)-two layers
Loose tube nominal diameter (mm) 2,3 2,3 2,3 2,3
FRP/coat. CSM nominal thickness (mm) 2,5 2,5 / 3,9 2,8 / 6,7 2,5
Outer jacket nominal thickness (mm) 1,4 1,4 1,4 1,4
Cable nominal outer diameter (mm) 11,0 12,5 15,3 15,7
Cable informative weight (kg/km) 120 150 220 230
Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
All-dielectric Duct Cables with improved rodent protection
UT.x2,3GF
97
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1
UT6x.. UT8x.. UT3x.. UT9x..
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
longterm
1100 N
1200 N
1500 N
1500N
shortterm
3500 N
4000 N
5000 N
5000N
Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB
Temperature range of use
-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11
Fire performance
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Eca
Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1
UT6x2,3GF Ø 11,0 Eca
4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B
4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B
6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B
6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B
6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B
UT8x2,3GF Ø 12,5 Eca 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B
8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B
UT3x2,3GF Ø 15,3 Eca 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B
12 x 12f 144f 12.12.M3.B 12.12.M4.B R851129 12.12.S7.B
UT9x2,3GF Ø 15,7 Eca
18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B
18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B
18 x 12f 216f 18.12.M3.B 18.12.M4.B 18.12.S2.B 18.12.S7.B
Order code e.g.: UT8x2,3GF 08.08.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Multi Loose Tube Cables
98
R&M generates added value. Connectivity that matters.Cable construction code DIN code
OT.x2,3LWH xx.yy.zz.c A-DQ2YB2Y (R...vzk) nx2,3
1. FRP central strength member2. Water swellable yarn3. Rip-cord4. Gel filled PBT loose tube with optical fibers5. LDPE UV stable inner jacket6. Zn galvanized steel wire armour fixed by PET tape7. HDPE UV stable outer jacket
Cable general description
Multi Loose Tube steel wire armoured cable with two jackets for outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.
Construction and dimensions OT6x2,3LWH OT8x2,3LWH OT3x2,3LWH
Max. fiber count (12 fibers/tube) 72 96 144
Loose-tubes count 6 8 12
Loose tube nominal diameter (mm) 2,3 2,3 2,3
FRP/coat. CSM nominal thickness (mm) 2,5 2,5 / 3,8 2,5 / 6,7
Inner jacket nominal thickness (mm) 1,0 1,0 1,0
Steel wire nominal diameter (mm) 1,0 1,0 1,3
Outer jacket nominal thickness (mm) 1,3 1,3 1,3
Cable nominal outer diameter (mm) 14,5 15,8 19,4
Cable informative weight (kg/km) 330 385 610
Standard put-up length (m) 2100/4100 ± 5% 2100/4100 ± 5% 2100/4100 ± 5%
Outer jacket
Material UV stable HDPE
Jacket colour Black
Sheath marking Ink-Jet, white
Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Steel Wire Armoured Cables SWA
OT.x2,3LWH
99
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1
OT6x.. OT8x.. OT3x..
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
longterm n.a. n.a. n.a.
shortterm
5000 N
6000 N
8000 N
Crush EN 60794-1-21:E3A 2000 N/100mm (long term)4000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 25 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB
Temperature range of use
-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath
* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1
OT6x2,3LWH Ø 14,5
4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B
4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B
6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B
6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B
OT8x2,3LWH Ø 15,8 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B
8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B
OT3x2,3LWH Ø 19,4 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B
12 x 12f 144f 12.12.M3.B 12.12.M4.B R851130 12.08.S7.B
Order code e.g.: OT6x2,3LWH 06.08.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Multi Loose Tube Cables
100
R&M generates added value. Connectivity that matters.Cable construction code DIN code
UT.x2,3FWF xx.yy.zz.c J/A-DQHBH (R...vzk) nx2,3
1. FRP central strength member2. Water swellable yarn3. Rip-cord4. Gel filled PBT loose tube with optical fibers5. FRLSZH UV stable inner jacket6. Zn galvanized steel wire armour fixed by PET tape7. FRLSZH UV stable outer jacket
Cable general description
Multi Loose Tube steel wire armoured cable with two jackets for indoor or outdoor duct or direct buried installation.
Construction and dimensions UT6x2,3FWF UT8x2,3FWF UT3x2,3FWF
Max. fiber count (12 fibers/tube) 72 96 144
Loose-tubes count 6 8 12
Loose tube nominal diameter (mm) 2,3 2,3 2,3
FRP/coat. CSM nominal thickness (mm) 2,5 2,5 / 3,8 2,5 / 6,7
Inner jacket nominal thickness (mm) 1,0 1,0 1,0
Steel wire nominal diameter (mm) 1,0 1,0 1,3
Outer jacket nominal thickness (mm) 1,3 1,3 1,3
Cable nominal outer diameter (mm) 14,5 15,8 19,4
Cable informative weight (kg/km) 370 430 670
Standard put-up length (m) 2100/4100 ± 5% 2100/4100 ± 5% 2100/4100 ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Steel Wire Armoured Cables SWA
UT.x2,3FWF
101
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1
UT6x.. UT8x.. UT3x..
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
longterm n.a. n.a. n.a.
shortterm
5000 N
6000 N
8000 N
Crush EN 60794-1-21:E3A 2000 N/100mm (long term)4000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 25 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB
Temperature range of use
-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath
* EN 60794-3-10, EN 60794-3-11
Fire performance
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Fca
Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1
UT6x2,3FWF Ø 14,5 Fca
4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B
4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B
6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B
6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B
UT8x2,3FWF Ø 15,8 Fca 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B
8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B
UT3x2,3FWF Ø 19,4 Fca 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B
12 x 12f 144f 12.12.M3.B 12.12.M4.B R851131 12.08.S7.B
Order code e.g.: UT6x2,3FWF 06.08.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Multi Loose Tube Cables
102
R&M generates added value. Connectivity that matters.Cable construction code DIN code
OT.x1,7ECH xx.yy.zz.c A-DQ(ZN)(SR)2Y wbg nx1,7
1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable e-glass yarn5. Rip-cord6. Corrugated steel tape armour7. HDPE UV stable outer jacket
Cable general description
Multi Loose Tube corrugated steel tape armoured cable for outdoor duct or direct buried installation. This cable construction offers full rodent protection.
Construction and dimensions OT6x1,7ECH OT8x1,7ECH OT3x1,7ECH OT9x1,7ECH
Max. fiber count (12 fibers/tube) 72 96 144 216
Loose-tubes count 6 8 12 18(6+12)-two layers
Loose tube nominal diameter (mm) 1,7 1,7 1,7 1,7
FRP/coat. CSM nominal thickness (mm) 1,7 2,8 2,5/5,0 1,7
Outer jacket nominal thickness (mm) 1,3 1,3 1,3 1,3
Cable nominal outer diameter (mm) 11,0 12,0 14,0 14,0
Cable informative weight (kg/km) 115 140 185 185
Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%
Outer jacket
Material UV stable HDPE
Jacket colour Black
Sheath marking Ink-Jet, white
Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Corrugated Steel Tape Armoured Cables CSTA
OT.x1,7ECH
103
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1
OT6x.. OT8x.. OT3x.. OT9x..
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
longterm
800 N
1200 N
1200 N
1100N
shortterm
2500 N
4000 N
4000 N
3500N
Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB
Temperature range of use
-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1
OT6x1,7ECH Ø 11,0
4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B
4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B
6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B
6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B
6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B
OT8x1,7ECH Ø 12,0 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B
8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B
OT3x1,7ECH Ø 14,0 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B
12 x 12f 144f 12.12.M3.B 12.12.M4.B R851129 12.12.S7.B
OT9x1,7ECH Ø 14,0
18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B
18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B
18 x 12f 216f 18.12.M3.B 18.12.M4.B R851132 18.12.S7.B
Order code e.g.: OT6x1,7ECH 04.08.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Multi Loose Tube Cables
104
R&M generates added value. Connectivity that matters.Cable construction code DIN code
UT.x1,7ECF xx.yy.zz.c J/A-DQ(ZN)(SR)H wbg nx1,7
1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable e-glass yarn5. Rip-cord6. Corrugated steel tape armour7. FRLSZH UV stable outer jacket
Cable general description
Multi Loose Tube corrugated steel tape armoured cable for indoor or outdoor duct or direct buried installation. This cable construction offers full rodent protection.
Construction and dimensions OT6x1,7ECF OT8x1,7ECF OT3x1,7ECF OT9x1,7ECF
Max. fiber count (12 fibers/tube) 72 96 144 216
Loose-tubes count 6 8 12 18(6+12)-two layers
Loose tube nominal diameter (mm) 1,7 1,7 1,7 1,7
FRP/coat. CSM nominal thickness (mm) 1,7 2,8 2,5/5,0 1,7
Outer jacket nominal thickness (mm) 1,3 1,3 1,3 1,3
Cable nominal outer diameter (mm) 11,0 12,0 14,0 14,0
Cable informative weight (kg/km) 135 165 210 210
Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Corrugated Steel Tape Armoured Cables CSTA
UT.x1,7ECF
105
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1
UT6x.. UT8x.. UT3x.. UT9x..
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
longterm
800N
1200 N
1200 N
1100N
shortterm
2500 N
4000 N
4000 N
3500N
Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB
Temperature range of use
-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11
Fire performance
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Fca
Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1
UT6x1,7ECF Ø 11,0 Fca
4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B
4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B
6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B
6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B
6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B
UT8x1,7ECF Ø 12,0 Fca 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B
8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B
UT3x1,7ECF Ø 14,0 Fca 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B
12 x 12f 144f 12.12.M3.B 12.12.M4.B R851129 12.12.S7.B
UT9x1,7ECF Ø 14,0 Fca
18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B
18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B
18 x 12f 216f 18.12.M3.B 18.12.M4.B R851133 18.12.S7.B
Order code e.g.: UT6x1,7ECF 06.06.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Multi Loose Tube Cables
106
R&M generates added value. Connectivity that matters.Cable construction code DIN code
OT.x1,7ELCH xx.yy.zz.c A-DQ(ZN)2Y(SR)2Y wbg nx1,7
1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable e-glass yarn5. Rip-cord6. LDPE UV stable inner jacket7. Corrugated steel tape armour8. HDPE UV stable outer jacket
Cable general description
Multi Loose Tube corrugated steel tape armoured cable with two jackets for outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.
Construction and dimensions OT6x1,7ELCH OT8x1,7ELCH OT3x1,7ELCH OT9x1,7ELCH
Max. fiber count (12 fibers/tube) 72 96 144 216
Loose-tubes count 6 8 12 18(6+12)-two layers
Loose tube nominal diameter (mm) 1,7 1,7 1,7 1,7
FRP/coat. CSM nominal thickness (mm) 1,7 2,8 2,5/5,0 1,7
Inner jacket nominal thickness (mm) 0,9 0,9 0,9 0,9
Outer jacket nominal thickness (mm) 1,3 1,3 1,3 1,3
Cable nominal outer diameter (mm) 12,1 13,1 15,1 16,1
Cable informative weight (kg/km) 145 175 220 240
Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%
Outer jacket
Material UV stable HDPE
Jacket colour Black
Sheath marking Ink-Jet, white
Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Corrugated Steel Tape Armoured Cables CSTA
OT.x1,7ELCH
107
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1
OT6x.. OT8x.. OT3x.. OT9x..
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
longterm
800 N
1200 N
1200 N
1200N
shortterm
2500 N
4000 N
4000 N
4000N
Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 25 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB
Temperature range of use
-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath
* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1
OT6x1,7ELCH Ø 12,1
4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B
4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B
6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B
6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B
6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B
OT8x1,7ELCH Ø 13,1 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B
8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B
OT3x1,7ELCH Ø 15,1 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B
12 x 12f 144f 12.12.M3.B 12.12.M4.B R851129 12.12.S7.B
OT9x1,7ELCH Ø 16,1
18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B
18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B
18 x 12f 216f 18.12.M3.B 18.12.M4.B R851134 18.12.S7.B
Order code e.g.: OT6x1,7ELCH 18.06.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Multi Loose Tube Cables
108
R&M generates added value. Connectivity that matters.Cable construction code DIN code
UT.x1,7EFCF xx.yy.zz.c J/A-DQ(ZN)H(SR)H wbg nx1,7
1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Water swellable e-glass yarn5. Rip-cord6. FRLSZH UV stable inner jacket7. Corrugated steel tape armour8. FRLSZH UV stable outer jacket
Cable general description
Multi Loose Tube corrugated steel tape armoured cable with two jackets for indoor or outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.
Construction and dimensions OT6x1,7EFCF OT8x1,7EFCF OT3x1,7EFCF OT9x1,7EFCF
Max. fiber count (12 fibers/tube) 72 96 144 216
Loose-tubes count 6 8 12 18(6+12)-two layers
Loose tube nominal diameter (mm) 1,7 1,7 1,7 1,7
FRP/coat. CSM nominal thickness (mm) 1,7 2,8 2,5/5,0 1,7
Inner jacket nominal thickness (mm) 0,9 0,9 0,9 0,9
Outer jacket nominal thickness (mm) 1,3 1,3 1,3 1,3
Cable nominal outer diameter (mm) 12,1 13,1 15,1 16,1
Cable informative weight (kg/km) 180 210 270 290
Standard put-up length (m) 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5% 2100 / 4100±5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Corrugated Steel Tape Armoured Cables CSTA
UT.x1,7EFCF
109
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1
UT6x.. UT8x.. UT3x.. UT9x..
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
longterm
800N
1200 N
1200 N
1100N
shortterm
2500 N
4000 N
4000 N
4000N
Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 25 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB
Temperature range of use
-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath
* EN 60794-3-10, EN 60794-3-11
Fire performance
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Fca
Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1
UT6x1,7EFCF Ø 12,1 Fca
4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B
4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B
6 x 6f 36f 06.06.M3.B 06.06.M4.B 06.06.S2.B 06.06.S7.B
6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B
6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B
UT8x1,7EFCF Ø 13,1 Fca 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B
8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B
UT3x1,7EFCF Ø 15,1 Fca 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B
12 x 12f 144f 12.12.M3.B 12.12.M4.B R851129 12.12.S7.B
UT9x1,7EFCF Ø 16,1 Fca
18 x 6f 108f 18.06.M3.B 18.06.M4.B 18.06.S2.B 18.06.S7.B
18 x 8f 144f 18.08.M3.B 18.08.M4.B 18.08.S2.B 18.08.S7.B
18 x 12f 216f 18.12.M3.B 18.12.M4.B R851135 18.12.S7.B
Order code e.g.: UT3x1,7EFCF 12.08.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Multi Loose Tube Cables
110
R&M generates added value. Connectivity that matters.Cable construction code DIN code
QT.x2,3GF xx.yy.zz.c J/A-DQ(BN)H wbg nx2,3 fr
1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Fire-resistant tape5. Water swellable e-glass yarn6. Rip-cord7. FRLSZH UV stable outer jacket
Cable general description
Multi Loose Tube non-metallic fire-resistant cable with improved rodent protection for indoor or outdoor duct installation.
Construction and dimensions QT6x2,3GF QT8x2,3GF QT3x2,3GF
Max. fiber count (12 fibers/tube) 72 96 144
Loose-tubes count 6 8 12
Loose tube nominal diameter (mm) 2,3 2,3 2,3
FRP/coat. CSM nominal thickness (mm) 2,8 2,5 / 4,5 2,8 / 7,8
Outer jacket nominal thickness (mm) 1,8 1,8 1,8
Cable nominal outer diameter (mm) 13,0 14,6 18,0
Cable informative weight (kg/km) 180 225 340
Standard put-up length (m) 2100/4100 ± 5% 2100/4100 ± 5% 2100/4100 ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Fire Resistant Cables All-dielectric Non-armoured
QT.x2,3GF
111
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1
UT6x.. UT8x.. UT3x..
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
longterm
1400N
1400N
1800N
shortterm
4500 N
4500 N
6000 N
Crush EN 60794-1-21:E3A 1000 N/100mm (long term)2000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB
Temperature range of use
-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-3-10, EN 60794-3-11
Fire performance
Fire resistance EN 60331-25 (180 min at 750°C) Pass
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Fca
Cable expected lifetime / min. 30 yearsOrder information
Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1
QT6x2,3GF Ø 13,0 Fca
4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B
4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B
6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B
6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B
QT8x2,3GF Ø 14,6 Fca 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B
8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B
QT3x2,3GF Ø 18,0 Fca 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B
12 x 12f 144f 12.12.M3.B 12.12.M4.B R851136 12.12.S7.B
Order code e.g.: QT6x2,3GF 04.08.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Multi Loose Tube Cables
112
R&M generates added value. Connectivity that matters.
Fire Resistant Cables Corrugated Steel Tape Armoured
QT.x2,3EFCF
Cable construction code DIN code
QT.x2,3EFCF xx.yy.zz.c J/A-DQ(ZN)H(SR)H wbg nx2,3 fr
1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Fire-resistant tape5. Water swellable e-glass yarn6. Rip-cord7. FRLSZH UV stable inner jacket8. Corrugated steel tape armour9. FRLSZH UV stable outer jacket
Cable general description
Multi Loose Tube fire resistant corrugated steel tape armoured cable with two jackets for indoor or outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.
Construction and dimensions QT6x2,3EFCF QT8x2,3EFCF QT3x2,3EFCF
Max. fiber count (12 fibers/tube) 72 96 144
Loose-tubes count 6 8 12
Loose tube nominal diameter (mm) 2,3 2,3 2,3
FRP/coat. CSM nominal thickness (mm) 2,8 2,5 / 4,5 2,8 / 7,8
Outer jacket nominal thickness (mm) 1,0 1,0 1,0
Cable nominal outer diameter (mm) 16,5 17,5 21,5
Cable informative weight (kg/km) 300 350 500
Standard put-up length (m) 2100/4100 ± 5% 2100/4100 ± 5% 2100/4100 ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
113
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1
QT6x.. QT8x.. QT3x..
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
longterm
900N
900N
1100N
shortterm
3000 N
3000 N
3500 N
Crush EN 60794-1-21:E3A 2500 N/100mm (long term)5000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB
Temperature range of use
-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath
* EN 60794-3-10, EN 60794-3-11
Fire performance
Fire resistance EN 60331-25 (180 min at 750°C) Pass
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Fca
Cable expected lifetime / min. 30 yearsOrder information
Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1
QT6x2,3EFCF Ø 16,5 Fca
4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B
4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B
6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B
6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B
QT8x2,3EFCF Ø 17,5 Fca 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B
8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B
QT3x2,3EFCF Ø 21,5 Fca 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B
12 x 12f 144f 12.12.M3.B 12.12.M4.B R851137 12.12.S7.B
Order code e.g.: QT8x2,3EFCF 08.08.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Multi Loose Tube Cables
114
R&M generates added value. Connectivity that matters.Cable construction code DIN code
QT.x2,3FWF xx.yy.zz.c J/A-DQHBH (R...vzk) nx2,3 fr
1. FRP central strength member2. Water swellable yarn3. Gel filled PBT loose tube with optical fibers4. Fire-resistant tape5. Rip-cord6. FRLSZH UV stable inner jacket7. Zn galvanized steel wire armour fixed by PET tape8. FRLSZH UV stable outer jacket
Cable general description
Multi Loose Tube fire resistant steel wire armoured cable with two jackets for indoor or outdoor duct or direct buried installation. This cable construction offers excellent mechanical and full rodent protection.
Construction and dimensions QT6x2,3FWF QT8x2,3FWF QT3x2,3FWF
Max. fiber count (12 fibers/tube) 72 96 144
Loose-tubes count 6 8 12
Loose tube nominal diameter (mm) 2,3 2,3 2,3
FRP/coat. CSM nominal thickness (mm) 2,8 2,5 / 4,5 2,5 / 7,8
Inner jacket nominal thickness (mm) 1,0 1,0 1,0
Steel wire nominal diameter (mm) 1,0 1,2 1,4
Outer jacket nominal thickness (mm) 1,4 1,4 1,4
Cable nominal outer diameter (mm) 15,6 17,7 21,1
Cable informative weight (kg/km) 440 570 800
Standard put-up length (m) 2100/4100 ± 5% 2100/4100 ± 5% 2100/4100 ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.-12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Loose-tube colour coding 1.red, 2.green (in each layer), rest of tubes white (fillers uncoloured or black)
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Fire Resistant Cables Steel Wire Armoured Cables
QT.x2,3FWF
115
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1
QT6x.. QT8x.. QT3x..
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
longterm n.a. n.a. n.a.
shortterm
5000 N
8000 N
10000 N
Crush EN 60794-1-21:E3A 2000 N/100mm (long term)4000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 25 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -40°C ÷ 70°C Δα ≤ 0,05 dB
Temperature range of use
-5°C ÷ 50°C-40°C ÷ 70°C-40°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage under inner sheath
* EN 60794-3-10, EN 60794-3-11
Fire performance
Fire resistance EN 60331-25 (180 min at 750°C) Pass
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Fca
Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 G652.D G657.A1
QT6x2,3FWF Ø 15,6 Fca
4 x 8f 32f 04.08.M3.B 04.08.M4.B 04.08.S2.B 04.08.S7.B
4 x 12f 48f 04.12.M3.B 04.12.M4.B 04.12.S2.B 04.12.S7.B
6 x 8f 48f 06.08.M3.B 06.08.M4.B 06.08.S2.B 06.08.S7.B
6 x 12f 72f 06.12.M3.B 06.12.M4.B 06.12.S2.B 06.12.S7.B
QT8x2,3FWF Ø 17,7 Fca 8 x 8f 64f 08.08.M3.B 08.08.M4.B 08.08.S2.B 08.08.S7.B
8 x 12f 96f 08.12.M3.B 08.12.M4.B 08.12.S2.B 08.12.S7.B
QT3x2,3FWF Ø 21,1 Fca 12 x 8f 96f 12.08.M3.B 12.08.M4.B 12.08.S2.B 12.08.S7.B
12 x 12f 144f 12.12.M3.B 12.12.M4.B R851138 12.12.S7.B
Order code e.g.: QT8x2,3FWF 08.08.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Multi Loose Tube Cables
118
R&M generates added value. Connectivity that matters.
FTTx Constructions Overview
Microcables
MT1RF 120 MT1RF xx.yy.zz.c indoor/outdoor 4 fibers 1 1.2
Flat self-supporting cables
ST1fH 122 ST1fH xx.yy.zz.c indoor/outdoor 12 fibers 1 1.9
Flat self-supporting cables
ST2fH 124 ST2fH xx.yy.zz.c indoor/outdoor 24 fibers 2 1.9
Non-metallic drop cables
UAF250 126 UAF250 00.yy.zz.c indoor/outdoor 6 fibers 12 fibers
0 n.a.
Non-metallic drop cables
UAF1000 128 UAF1000 00.yy.zz.c indoor/outdoor 2 fibers 8 fibers 12 fibers
0 n.a.
Cable type Construction Page Construction code ApplicationFiber count[fibers]
Loose tubes count
Loose tube nominal Ø [mm]
Jacket material
Euro classification to CPR
Nominal cable Ø [mm]
Cable weight [kg/km]
Tensile performance [N]
Crush [N/100mm]
Temperatur range in operation
Fire resistance – EN 60331-25
119
Microcables
MT1RF 120 MT1RF xx.yy.zz.c indoor/outdoor 4 fibers 1 1.2
Flat self-supporting cables
ST1fH 122 ST1fH xx.yy.zz.c indoor/outdoor 12 fibers 1 1.9
Flat self-supporting cables
ST2fH 124 ST2fH xx.yy.zz.c indoor/outdoor 24 fibers 2 1.9
Non-metallic drop cables
UAF250 126 UAF250 00.yy.zz.c indoor/outdoor 6 fibers 12 fibers
0 n.a.
Non-metallic drop cables
UAF1000 128 UAF1000 00.yy.zz.c indoor/outdoor 2 fibers 8 fibers 12 fibers
0 n.a.
FRLSZH Fca 3.0 11.0 150 500 -20°C to 70°C
HDPE 8.0 x 4.0 38.0 1'600 4'000 -20°C to 70°C
HDPE 9.8 x 4.0 59.0 1'600 4'000 -20°C to 70°C
FRLSZH Fca2.83.2
9.011.0
250 1'000 -20°C to 70°C
FRLSZH Fca3.23.63.8
11.013.014.0
250 1'000 -20°C to 70°C
Cable type Construction Page Construction code ApplicationFiber count[fibers]
Loose tubes count
Loose tube nominal Ø [mm]
Jacket material
Euro classification to CPR
Nominal cable Ø [mm]
Cable weight [kg/km]
Tensile performance [N]
Crush [N/100mm]
Temperatur range in operation
Fire resistance – EN 60331-25
120
R&M generates added value. Connectivity that matters.
Cable general description
Max. 4 fiber uni-tube non-metallic micro-cable for indoor or outdoor installation to micro-tubes.
Construction and dimensions
Loose tube nominal diameter 1,2 mm
Outer jacket nominal thickness 0,9 mm
Cable nominal outer diameter 3,0 mm
Cable informative weight 11 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.–4.: red, green, blue, yellow
Fiber type Single- and multi-mode fibers (OS2)
Geometrical and transmission parameters are available at separate generic datasheet
Cable construction code DIN code
MT1RF xx.yy.zz.c J/A-DQ(ZN)H (2FRP 0,5)
1. Gel filled PBT loose tube with optical fibers2. FRP strength members3. FRLSZH UV stable outer jacket
Microcables MT1RF
121
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 150 N (short term) Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 500 N/100mm (short term) Δα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 1 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,1 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=40 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 2 m, rotation angle ±180°, 10 cycles no damage
Kink EN 60794-1-21:E10 d = 40 x cable diameter no damage
Bend no tension EN 60794-1-21:E11A R = 40 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C -30°C ÷ 70°C
Δα ≤ 0,05 dB Δα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-20°C ÷ 70°C-30°C ÷ 70°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L = 3 m,1 m water height, 24 h no water leakage
* EN 60794-5-10
Fire performance
Flammability - cable bundle EN 60332-3-22 (cat.A) Pass
Smoke density EN 61034-1, EN 61034-2 Pass
Halogen Free, Acid gases EN 60754-2 Pass
Euro classification to CPR EN 50575, EN 13501-6 Fca
Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count G657.A1 G657.A2
MT1RF Ø 3,0 Fca2 01.02.S7.B 01.02.S8.B
4 01.04.S7.B R851139
Order code e.g.: MT1RF 01.02.S7.B (see page 136/137) Other fiber counts and/or fiber types on special request
FTTx Constructions
122
R&M generates added value. Connectivity that matters.
Cable general description
Max. 12 fiber uni-tube non-metallic flat self-supporting cable for outdoor aerial or direct buried installation.
Construction and dimensions
Loose tube nominal diameter 1,9 mm
Outer jacket nominal thickness 1,0 mm
Cable nominal outer diameter 8,0 x 4,0 mm
Cable informative weight 38 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable HDPE
Jacket colour Black
Sheath marking Ink-Jet, white
Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.–12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Fiber type Single- and multi-mode fibers (OS2)
Geometrical and transmission parameters are available at separate generic datasheet
Cable construction code DIN code
ST1fH xx.yy.zz.c A-D(ZN)2YT (2FRP 2,0)
1. Gel filled PBT loose tube with optical fibers2. FRP strength members3. Rip-cord4. HDPE UV stable outer jacket
Flat self-supporting cables ST1fH
123
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 1600 N (max. allow-able tension) Δα ≤ 0,15 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 2000 N/100mm (long term) **4000 N/100mm (short term)**
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=150 mm, 25 cycles no damage
Torsion EN 60794-1-21:E7 L=2 m, rotation angle ±180°, 5 cycles no damage
Bend no tension EN 60794-1-21:E11A R=150 mm, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Bend under tension EN 60794-1-21:E18AL=2 m, R=150 mm, bend angle 45°, maximum allow-able tension, 20 cycles
Δα ≤ 0,05 dB after test, no damage
Maximal recommended span
TELENCO clamp ODWAC 5126 70 m (minimal mid-span sag 1 m) Δα ≤ 0,05 dB, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C -30°C ÷ 70°C
Δα ≤ 0,05 dB Δα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-20°C ÷ 70°C-30°C ÷ 70°C
installationoperationstorage, transport
* EN 60794-5-10, ** applied on flat side Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count G657.A1 G657.A2
ST1fH Ø 8,0 x 4,0
4 01.04.S7.B 01.04.S8.B
6 01.06.S7.B 01.06.S8.B
8 01.08.S7.B 01.08.S8.B
12 01.12.S7.B R851140
Order code e.g.: ST1fH 01.04.S7.B (see page 136/137) Other fiber counts and/or fiber types on special request
FTTx Constructions
124
R&M generates added value. Connectivity that matters.
Cable general description
Max. 2 x12 fiber uni-tube non-metallic flat self-supporting cable for outdoor aerial or direct buried installation.
Construction and dimensions
Loose tube nominal diameter 1,9 mm
Outer jacket nominal thickness 1,0 mm
Cable nominal outer diameter 9,8 x 4,0 mm
Cable informative weight 59 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable HDPE
Jacket colour Black
Sheath marking Ink-Jet, white
Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.–12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Loose-tube colour coding 1. red, 2. white
Fiber type Single- and multi-mode fibers (OS2)
Geometrical and transmission parameters are available at separate generic datasheet
Cable construction code DIN code
ST2fH xx.yy.zz.c A-D(ZN)2YT (2FRP 2,0)
1. Gel filled PBT loose tube with optical fibers2. FRP strength members3. Rip-cord4. HDPE UV stable outer jacket
Flat self-supporting cables ST2fH
125
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 1600 N (max. allow-able tension) Δα ≤ 0,15 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 2000 N/100mm (long term) **4000 N/100mm (short term)**
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 10 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=150 mm, 25 cycles no damage
Torsion EN 60794-1-21:E7 L=2 m, rotation angle ±180°, 5 cycles no damage
Bend no tension EN 60794-1-21:E11A R=150 mm, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Bend under tension EN 60794-1-21:E18AL=2 m, R=150 mm, bend angle 45°, maximum allow-able tension, 20 cycles
Δα ≤ 0,05 dB after test, no damage
Maximal recommended span
TELENCO clamp ODWAC 5126 70 m (minimal mid-span sag 1 m) Δα ≤ 0,05 dB, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -20°C ÷ 70°C -30°C ÷ 70°C
Δα ≤ 0,05 dB Δα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-20°C ÷ 70°C-30°C ÷ 70°C
installationoperationstorage, transport
* EN 60794-5-10, ** applied on flat side Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count G652.D G657.A1 G657.A2
ST2fH Ø 9,8 x 4,0
2 x 6f 12f 02.06.S2.B 02.06.S7.B 02.06.S8.B
2 x 8f 16f 02.08.S2.B 02.08.S7.B 02.08.S8.B
2 x 12f 24f 02.12.S2.B 02.12.S7.B R851160
Order code e.g.: ST2fH 02.06.S2.B (see page 136/137) Other fiber counts and/or fiber types on special request
FTTx Constructions
126
R&M generates added value. Connectivity that matters.
Cable general description
Max. 12 fiber non-metallic drop cable for indoor or outdoor aerial installation.
Construction and dimensions
Fiber count 1–6 8–12
Outer jacket nominal thickness (mm) 0,8 0,8
Cable nominal outer diameter (mm) 2,8 3,2
Cable informative weight (kg/km) 9 11
Standard put-up length (m) 2100/4100 ± 5% 2100/4100 ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.–12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Fiber type Bending optimized Single- and multi-mode fibers (OS2)
Geometrical and transmission parameters are available at separate generic datasheet
Cable construction code DIN code
UAF250 00.yy.zz.c J/A-(ZN)H
1. Optical fibers2. Aramid strength members3. FRLSZH UV stable outer jacket
Non-metallic drop cables UAF250
127
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 250 N (max. allow-able tension) Δα ≤ 0,15 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 500 N/100mm (long term)1000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 3 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=15 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L=2 m, rotation angle ±180°, 5 cycles no damage
Bend no tension EN 60794-1-21:E11A R=40 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Bend under tension EN 60794-1-21:E18AL=2 m, R=150 mm, bend angle 45°, maximum allow-able tension, 20 cycles
Δα ≤ 0,05 dB after test, no damage
Maximal recommended span
TELENCO clamp 7593
40 m (minimal sag 60 cm), maximum allow-able tension Δα ≤ 0,05 dB, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -20°C ÷ 60°C -25°C ÷ 60°C
Δα ≤ 0,05 dB Δα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-20°C ÷ 60°C-25°C ÷ 60°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L=3 m,1 m water height, 24 h no water leakage
* EN 60794-3-20
Fire performance
Euro classification to CPR EN 50575, EN 13501-6 Fca
Cable expected lifetime / min. 30 years
FTTx Constructions
Order information
Construction Diameter CPR Fiber count G652.D G657.A1 G657.A2
UAF250
Ø 2,8 Fca
1 01.01.S2.B 01.01.S7.B 01.01.S8.B
2 01.02.S2.B 01.02.S7.B 01.02.S8.B
4 01.04.S2.B 01.04.S7.B 01.04.S8.B
6 01.06.S2.B 01.06.S7.B R851161
Ø 3,2 Fca8 01.08.S2.B 01.08.S7.B 01.08.S8.B
12 01.12.S2.B 01.12.S7.B R851162
Order code e.g.: UAF250 01.01.S2.B (see page 136/137) Other fiber counts and/or fiber types on special request
128
R&M generates added value. Connectivity that matters.
Cable general description
Max. 12 fiber non-metallic drop cable for indoor or outdoor aerial installation.
Construction and dimensions
Fiber count 1–2 4–8 10–12
Outer jacket nominal thickness (mm) 0,8 0,8 0,8
Cable nominal outer diameter (mm) 3,2 3,6 3,8
Cable informative weight (kg/km) 11 13 14
Standard put-up length (m) 2100/4100 ± 5% 2100/4100 ± 5% 2100/4100 ± 5%
Outer jacket
Material UV stable FRLSZH
Jacket colour Black. Other colours available on request
Sheath marking Ink-Jet, white or black depending on the jacket colour
Print legend Construction name, cable type, batch-number, meter-marking, CE marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.–12.: red, green, blue, yellow, white, grey, brown, violet, turquoise, black, orange, pink
Fiber type Bending optimized Single- and multi-mode fibers (OS2)
Geometrical and transmission parameters are available at separate generic datasheet
Cable construction code DIN code
UAF1000 00.yy.zz.c J/A-(ZN)H
1. Optical fibers2. Aramid strength members3. FRLSZH UV stable outer jacket
Non-metallic drop cables UAF1000
129
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 1000 N (max. allow-able tension) Δα ≤ 0,15 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 500 N/100mm (long term)1000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 3 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=15 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L=2 m, rotation angle ±180°, 5 cycles no damage
Bend no tension EN 60794-1-21:E11A R=40 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Bend under tension EN 60794-1-21:E18AL=2 m, R=150 mm, bend angle 45°, maximum allow-able tension, 20 cycles
Δα ≤ 0,05 dB after test, no damage
Maximal recommended span
TELENCO clamp 7593
60 m (minimal sag 90 cm), maximum allow-able tension Δα ≤ 0,05 dB, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -20°C ÷ 60°C -25°C ÷ 60°C
Δα ≤ 0,05 dB Δα ≤ 0,15 dB, reversible
Temperature range of use
-5°C ÷ 50°C-20°C ÷ 60°C-25°C ÷ 60°C
installationoperationstorage, transport
Moisture resistance EN 60794-1-22:F5B L=3 m,1 m water height, 24 h no water leakage
* EN 60794-3-20
Fire performance
Euro classification to CPR EN 50575, EN 13501-6 Fca
Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count G652.D G657.A1 G657.A2
UAF1000
Ø 3,2 Fca1 01.01.S2.B 01.01.S7.B 01.01.S8.B
2 01.02.S2.B 01.02.S7.B R851163
Ø 3,6 Fca
4 01.04.S2.B 01.04.S7.B R851164
6 01.06.S2.B 01.06.S7.B 01.06.S8.B
8 01.08.S2.B 01.08.S7.B 01.08.S8.B
Ø 3,8 Fca 12 01.12.S2.B 01.12.S7.B R851165
Order code e.g.: UAF1000 01.01.S2.B (see page 136/137) Other fiber counts and/or fiber types on special request
FTTx Constructions
132
R&M generates added value. Connectivity that matters.Cable construction code
OssWH xx.yy.zz.c
1. Gel filled stainless-steel* loose tube with optical fibers2. Stainless-steel* wire armour3. HDPE UV stable outer jacket
* AISI 304 (1.4301)
Cable general description
Thixotropic gel filled stainless-steel loose-tube (SSLT) with max. 4 optic fibers. Stainless-steel wire armour (SSWA) provides the cable with high tensile strength and crush resistance. This fully rodent resistant cable is suitable for outdoor duct or direct buried (to ground or concrete) installation and is designed to be used in wide range of applications, besides others as e.g. strain or temperature sensing cable.
Construction and dimensions
Loose tube nominal diameter 1,8 mm
Steel wire nominal diameter 0,6 mm
Outer jacket nominal thickness 0,5 mm
Cable nominal outer diameter 4,0 mm
Cable informative weight 45 kg/km
Standard put-up length 2100/4100 m ± 5%
Outer jacket
Material UV stable HDPE (FRLSZH or PA on request)
Jacket colour Black
Sheath marking Ink-Jet, white
Print legend Construction name, cable type, batch-number, meter-marking,Customer print legend available on request
Optical fibers
Colour coding (IEC 60304) 1.–4.: red, green, blue, yellow
Fiber type Single- and multi-mode fibers (OS2, OM2, OM3, OM4, OM5)
Geometrical and transmission parameters are available at separate generic datasheet
Sensor CablesOssWH
133
Mechanical characteristics
Test Test method Value Acceptance criteria*
Tensile performance EN 60794-1-21:E1 1000 N (long term) 2000 N (short term)
Δα ≤ 0,05 dB Δα ≤ 0,05 dB after test
Crush EN 60794-1-21:E3A 4000 N/100mm (long term)8000 N/100mm (short term)
Δα ≤ 0,05 dB prior release, no damageΔα ≤ 0,05 dB after release, no damage
Impact EN 60794-1-21:E4 20 Nm, 3 impacts, d=20 mm, R=300 mm Δα ≤ 0,05 dB after test, no damage
Repeated bending EN 60794-1-21:E6 R=20 x cable diameter, 25 cycles no damage
Torsion EN 60794-1-21:E7 L = 1 m, rotation angle ±180°, 10 cycles no damage
Bend no tension EN 60794-1-21:E11A R=15 x cable diameter, 4 turns, 3 cycles Δα ≤ 0,05 dB after test, no damage
Environmental characteristics
Test Test method Value Acceptance criteria*
Temperature cycling EN 60794-1-22:F1 -40°C ÷ 80°C-40°C ÷ 80°C
Δα ≤ 0,05 dB Δα ≤ 0,15 dB, reversible
Temperature range of use
-10°C ÷ 50°C-40°C ÷ 80°C-40°C ÷ 80°C-50°C ÷ 150°C
installationoperationstorage, transportshort term max. 60 min
* EN 60794-3-10, EN 60794-3-11 Cable expected lifetime / min. 30 years
Order information
Construction Diameter CPR Fiber count OM3 OM4 G652.D
OssWH Ø 4,0
1 01.01.M3.B 01.01.M4.B 01.01.S2.B
2 01.02.M3.B 01.02.M4.B 01.02.S2.B
4 01.04.M3.B 01.04.M4.B R851166
Order code e.g.: OssWH 01.01.M3.B (see page 136/137) Other fiber counts and/or fiber types (e.g. G657.A2) on special request
Sensor Cables
135
Fiber specifications.
Geometrical and Transmission ParametersFiber typeto ITU-T recom.:
OS2 (9/125)G.652.D
OS2 (9/125)A
G.657.A19/125
G.655.D9/125
G.655.E, G.656
Fiber Nomenclature S2 S7 S5 S6
Mode Field Diameter (μm) - typically@1310 nm@1550 nm
9.2 ± 0.410.4 ± 0.5 8.4 ± 0.6 8.6 ± 0.4
Cladding Diameter (μm) 125 ± 0.7
Coating Diameter (μm) 242 ± 7
Attenuation 8 (dB/km)typical / max. (single fiber) @ 1310 nmtypical / max. (single fiber) @ 1550 nmtypical / max. (single fiber) @ 1625 nm
0.31 / 0.360.20 / 0.250.21 / 0.27
0.25 / 0.300.27 / 0.34
Fiber typeOM1
(62,5/125)OM2
(50/125)A
OM3 (50/125)A
OM4 (50/125)A
OM5 (50/125)A
Fiber Nomenclature M1 M2 M3 M4 M5
Numerical Aperture (μm) 0.275 ± 0.01562.5 ± 2.5
0.200 ± 0.01550.0 ± 2.5Core Diameter (μm)
Cladding Diameter (μm) 125 ± 1.0
Coating Diameter (μm) 242 ± 5
Overfilled Modal Bandwidth (Mhz.km)@850 nm@ 1300 nm
_˃ 200_˃ 500
_˃ 500_˃ 500
_˃ 1500_˃ 500
_˃ 3500_˃ 500
Link Length (m)lGb/sl0Gb/s
<_ 220<_ 33
<_ 550<_ 82
<_ 1000<_ 300
<_ 1100<_ 550
Attenuation 8 (dB/km)typical / max. (single fiber) @ 850 nmtypical / max. (single fiber) @ 1300 nm
2.7 / 3.30.6 / 1.1
2.5 / 3.50.6 / 1.5
136
R&M generates added value. Connectivity that matters.DIN/VDE 0888 cable coding.
Application area
A outdoor cable AT divideable outdoor cable B loose tube jellyfree D loose tube with jelly F fiber H reinforced tube, empty J indoor cable U universal cable (for indoor and outdoor) V tight tube W reinforced tube, filled
Tube type
B loose tube, jelly free D loose tube, jelly filled H reinforced tube, jelly free V tight tube W reinforced tube, jelly filled
Cable construction
B reinforcement, armor F core filled Q dry and longitudinal watertight (ZN) non-metallic strain-relief (ZS) strain-relief with steel (SR) overlapping corrugated steel tape
Jacket material
H halogen free jacket (FRLSZH) Y PVC, polyvinylchloride 2Y PE, polyethylen (LDPE; HDPE) 4Y PA, polyamide 11Y PUR, polyurethane
Quantity of fiber resp. fiber bundling
n amount of fiber nxm amount of loose tube × amount of fiber per tube
Fiber type
E single-mode fiber (glass core/glass jacket) G multimode, graded index fiber (glass core/glass jacket) GK multimode, graded index fiber – PCF (glass core/plastic jacket) K multimode, step index fiber – PCF (glass core/plastic jacket) P plastic fiber – POF (plastic core/plastic jacket) S multimode step index fiber (glass core/glass jacket)
Core diameter
n diameter in μm e.g. 9, 50, 62.5, 200
Cladding diameter
n diameter in μm e.g. 125, 230
Attenuation
xx attenuation at wave length in dB/km
Wave length
A at 650 nm B at 850 nm F at 1300 nm (MM) F at 1310 nm (SM) H at 1550 nm
Bandwidth
yy MHz × 100 m bandwidth with POF fibers at 650 nm yy MHz × km bandwidth with MM fibers yy ps/(nm × km) dispersion with SM fibers
DIN VDE V 0888: 2018-02
137
Color code for fibers IEC 60304 – R&M Standard
Color code for fibers ANSI/TIA-598
Loose-tube color coding
Outer jacket color
Color codes.
1 2 3 4 5 6 7 8 9 10 11 12
blue orange green brown gray white red black yellow violet pink turquoise
13 14 15 16 17 18 19 20 21 22 23 24
bluering-marked
orangering-marked
greenring-marked
brownring-marked
grayring-marked
whitering-marked
redring-marked
transparentring-marked
yellowring-marked
violetring-marked
pinkring-marked
turquoisering-marked
1 2 3 4 5 18 filler filler
6–17...
red green white white white white black uncolored
1 2 3 4 5 6 7 8 9 10 11 12
red green blue yellow white gray brown violet turquoise black orange pink
13 14 15 16 17 18 19 20 21 22 23 24
redring-marked
greenring-marked
bluering-marked
yellowring-marked
whitering-marked
grayring-marked
brownring-marked
violetring-marked
turquoisering-marked
transparentring-marked
orangering-marked
pinkring-marked
B R G B Y W I G B V T O P
blackstandard
red green blue yellow white ivory gray brown violet turquoise orange pink
138
R&M generates added value. Connectivity that matters.
Cable construction partWay of installation
I indoor O outdoor U universal S ADSS (All Dielectric Self-Supporting) K Fig.8 (self-supporting with steel rope messenger) Q fire-resistant to EN60331-25 M mini/micro-cable (for blowing to micro-duct)
Buffer type
B 900μm tight buffer T gel filled PBT loose-tube (with up to 12 fibers) X gel filled PBT loose-tube (with up to 24 fibers) t flexible loose-tube (with up to 12 fibers) x flexible loose-tube s stainless-steel loose-tube
Buffer count & diameter in mm e.g. 6x2,3
1 unitube (LT) or simplex construction (TB) 2 2 loose-tubes (flat LT cable) or duplex construction (TB) 3 12 loose-tubes or tight-buffers 4 number of loose-tubes or tight-buffers 5 number of loose-tubes or tight-buffers 6 number of loose-tubes or tight-buffers 8 number of loose-tubes or tight-buffers 7 16(5+11) loose-tubes or tight-buffers (in two layers) 9 18(6+12) loose-tubes or tight-buffers (in two layers) 0 24(9+15) loose-tubes or tight-buffers (in two layers)
Water-blocking
J jelly filled cable core
Strength member(s) in/under sheath
A aramid yarns E e-glass yarns (standard rodent protection) G e-glass yarns (impoved rodent protection) R 2 FRP rods integrated in the outer sheath D 2 steel wires integrated in the outer sheath f 2 FRP rods under the outer sheath - flat construction
Armour
C corrugated steel tape armour (CSTA) W steel wire armour (SWA) P fiber reinforced plastic rod armour (FRPA) Z laminated aluminium tape under sheath
Sheath material
F FRLSZH (fire-retardant, low-smoke, zero-halogen) H HDPE (high-density polyethylene) L LDPE (low-density polyethylene) N PA (polyamide) Y PVC (polyvinylchloride) V PUR (polyurethane)
Coding of FOC constructions.
Fiber count & type partxx.yy.zz.c
xx number of tubes containing fibers yy fiber count per each of tubes zz fiber type c sheath colour
e.g. MT1H 01.04.M3.B
SM (single-mode, S) = zz
S2 G.652.D S5 G.655 S6 G.656 S7 G.657.A1 S8 G.657.A2/B2 S9 G.657.A3/B3
MM (multi-mode, M) = zz
M1 OM1 (BW 200/500 Mhz.km) M2 OM2 (BW 500/500 Mhz.km) M3 OM3 (BW 1500/500 Mhz.km) M4 OM4 (BW 3500/500 mhz.km) M5 OM5 (to be specified) M6 OM2+ (BW 600/1200 Mhz.km)
Outer sheath colour = c B black R red E green U blue Y yellow W white I ivory G grey N brown V violet T turquoise O orange P pink
030.5914
140
R&M generates added value. Connectivity that matters.
Construction Products Regulation. Euro class B2ca and class CcaProducts with very high or high fire protection, no continuous flame propagation, limited fire development, and a limited heat release rate.
Euro class DcaProducts with medium fire protection, continuous flame propagation, moderate fire development, and a limited heat release rate.
Euro class Eca Products with normal fire protection, exposure to a small flame may ignite the cable, low resistance to temperature increases.
Additional classification
Production/density of smokeThere are three classes for smoke production and density in cables: s1 weak smoke production s2 moderate smoke production s3 potentially strong smoke production
Euro classification (ca) Classification criteria Additional criteria
Assessing and examining the consistency of theperformance system
A EN ISO 1716Gross heat of combustion 1+
Verification documents:Type testing
Regular works auditRegular sampling of ongoing production
B1
EN 50399Heat release
Flame propagation
EN 60332-1-2Flame propagation
Smoke production(s1a, s1b, s2, s3)
EN 50399 / EN 61034-2
Acidity(a1, a2, a3)
EN 50267-2-3
Flaming droplets(d0, d1, d2)EN 50399
B2
C
D 3Verification documents:
Type testing
E EN 60332-1-2Flame propagation
F 4No verification documents
CPR.
141
Acid production/corrosivityThere are three classifications of corrosivity: a1 slightly corrosive fumes a2 moderately corrosive fumes a3 potentially highly corrosive fumes
Flaming dropletsThere are three classes for the production of flaming droplets: d0 no flaming droplets d1 flaming droplets for a short time d2 potentially long-lasting flaming droplets
Recommendations for the future use of EU fire protection classification
First and foremost, the CPR enables a comparison between the fire protection properties of different products. However, every member state is instructed and required to define the minimum necessary fire protection classification for the various applications themselves. The requirements placed on products can thus differ greatly across Europe for each building type. Therefore, the planner must check and comply with the local regulations. Various organizations and international associations have also declared their own recommendations, which sometimes go well beyond the legal minimum requirements. In consideration of cost vs. benefit, R&M makes the following recommendation:
Euro classification Additional classification Fire protection level of the installation cables
(Use recommendations from R&M)*Flame propagationHeat production
Smoke production/density
Acid production/corrosivity
Flaming droplets
Aca NA
B1ca NA
B2ca s1 a1 d1Very high
(e.g. escape routes, tunnels, high-risk industries)
Cca s1 a1 d1High
(e.g. hospitals, nursing homes, schools)
Dca s2 a2 d1Medium
(e.g. public buildings, hotels, airports, industrial environments)
EcaNormal
(e.g. normal office buildings, residential premises)
FcaLow
(not recommended)
* The necessary fire protection classification for installation cables is prescribed by the relevant fire prevention authority.
142
Global network The worldwide network of proprietary companies and certified partners creates the basis for the greatest possible customer proximity. Products and solutions from Reichle & De-Massari are available locally in more than 100 countries. The company's branches in Europe, Asia Pacific, the Middle East, North and Latin America together with partners guarantee that the sales/distribution, installation and maintenance of R&M solutions around the globe take place quickly and that local customer requirements are satisfied.
R&M supports projects from start to finish, i.e. from the planning of the networks, via installation, through to ongoing operation. Personal service and numerous satisfied customers worldwide. We give you the security of knowing you are working with the right partner!
R&M Headquarters R&M Manufacturing R&M Sales Offices
R&M – worldwide. From project planning to operation.
143
«R&M gave us excellent support during the project. The contact partners were always reachable. Everything we needed was delivered promptly.» Marco Thieme, graduate engineer and project manager at the Stuttgart-based engineering firm Schwarz, Sparkassen Academy in Stuttgart
Success stories
Together with our customers, we are constantly developing meaningful success stories that give valuable insight into the complex world of connectivity. A number of publications from all over the world and from various sectors and industries bear witness to R&M's partnership-based collaboration with its business partners. Manufacturers, partners and end customers all benefit from the content and diversified publication of the success stories.
Seminars, training and workshops
R&M regularly offers practice-oriented seminars, training sessions and workshops worldwide. Field reports and customer contributions illustrate the successful implementation of our products and solutions.
Warranty program
R&M pursues an uncompromising quality policy that encompasses everything from compo-nents to the running operation of the installations. R&M offers one of the most complete warranty programs in the structured cabling industry based on EN 50173-x, ISO/IEC 11801 and ANSI with 25-year warranty and life-long application guarantee.
Qualified Partner Program
R&M supports and promotes specialists in network technology and structured building cabling all over the world with its Qualified Partner Program. The partners qualified and certified by R&M thus guarantee identical, top quality standards worldwide.
We are represented by more than 100 qualified partners worldwide. Find your local partner at: www.rdm.com
Switzerland – Headquarters
Reichle & De-Massari AGwww.rdm.com
Czech Republic
Reichle & De-Massari Czech Republic a.s.www.rdm-czech.com
R&M
_FO
-Cab
les_
2018
_08.
18_E
N/0
8.18
© R
eich
le &
De-
Mas
sari
AG –
All
right
s re
serv
ed
Europe
AUSTRIAReichle & De-Massari Austria GmbH
BELGIUMReichle & De-Massari Benelux Sales Office
BULGARIAReichle & De-Massari EOOD
CZECH REPUBLIC Reichle & De-Massari Czech Republic a.s.
FRANCEReichle & De-Massari France Sàrl
GERMANYReichle & De-Massari GmbH
HUNGARYReichle & De-Massari (Mo.) Kft
ITALYReichle & De-Massari Italia Srl
NETHERLANDSReichle & De-Massari Netherlands B.V.
NORDICSReichle & De-Massari Nordics Sales Office
POLANDReichle & De-Massari Polska Sp. z o.o.
PORTUGALReichle & De-Massari Portugal Sales Office
ROMANIAReichle & De-Massari Romania Sales Office
RUSSIAN FEDERATIONReichle & De-Massari Russia Sales Office
SERBIA Reichle & De-Massari Serbia Sales Office
SLOVAKIA Reichle & De-Massari Slovakia Sales Office
SLOVENIA Reichle & De-Massari Slovenia Sales Office
SPAINReichle & De-Massari Iberia SL
SWITZERLANDReichle & De-Massari AG, Sales Office
UNITED KINGDOMReichle & De-Massari (UK) Ltd
North America
UNITED STATESR&M USA Inc.
Latin America
BRASILReichle & De-Massari Brasil Ltda
COLOMBIAReichle & De-Massari Colombia Sales Office
Asia Pacific
AUSTRALIA & NEW ZEALANDReichle & De-Massari Australia Pty Ltd
GREATER CHINA GROUPReichle & De-Massari China Co. Ltd.
INDIAR&M India Pvt Ltd
INDONESIAReichle & De-Massari Indonesia Sales Office
JAPANR&M Japan K.K.
MALAYSIAReichle & De-Massari Malaysia Sales Office
SINGAPOREReichle & De-Massari Far East (Pte) Ltd
Middle East, Turkey & Africa
EGYPTReichle & De-Massari Egypt Sales Office
JORDANReichle & De-Massari Jordan Sales Office
KENYAReichle & De-Massari Kenya Sales Office
KUWAIT Reichle & De-Massari Kuwait Sales Office
MOROCCOReichle & De-Massari Maroc Sàrl
OMAN Reichle & De-Massari Oman Sales Office
QATARReichle & De-Massari Qatar Sales Office
SAUDI ARABIAReichle & De-Massari Saudi Arabia Ltd
TURKEYReichle & De-Massari Elektronik Sanayi VE Ticaret Ltd Sirketi
UNITED ARAB EMIRATESReichle & De-Massari MEA FZE