F.F.D.M PNEUMAT products are supplied NON STERILE. For this … · 2014. 10. 28. · Ref ISO : 015...
Transcript of F.F.D.M PNEUMAT products are supplied NON STERILE. For this … · 2014. 10. 28. · Ref ISO : 015...
WWW.THOMAS-DENTALTOOLS.COMLEARN MORE ON / PLUS D’INFORMATIONS SUR
78/80, Avenue de la Prospective18020 Bourges Cedex (France)
Tél. +33 (0)2 48 23 27 37 • Fax : +33 (0)1 46 52 72 90E-mail : [email protected]
MADE INFRANCE
ENDODONTIC INSTRUMENTSINSTRUMENTS ENDODONTIQUES
DENTAL INSTRUMENTS USED FOR THE ROOT CANAL PREPARATIONINSTRUMENTS DENTAIRES UTILISES POUR LA PRÉPARATION CANALAIRE
F.F.D.M PNEUMAT products are supplied NON STERILE. For this reason,they must be cleaned, disinfected and sterilized before first use or re-useto prevent contamination.Steam sterilization in an autoclave for 18 minutes at 134°C
INSTRUMENTS ENDODONTIQUES
WWW.THOMAS-DENTALTOOLS.COMLEARN MORE ON / PLUS D’INFORMATIONS SUR
Vier
zon
• 02
48
75 0
0 93
ENDODONTICINSTRUMENTS
Les produits F.F.D.M. PNEUMAT sont livrés NON STERILES, ils doivent parconséquent, lors de la première utilisation ou dans le cas de réutilisation,être nettoyés, désinfectés et stérilisés, afin d’éviter tout risque de contamination. Stérilisation à la vapeur dans un autoclave à 134° C pendant 18 minutes. LNE : CMDCAS RECOGNIZED REGISTRAR
ENDOLINE
Our experience at your service
FFDM PNEUMAT
NORM / RÉFÉRENCE NORMATIVE: ISO 1797-1, ISO 3630
NF EN ISO 13485
MEDICAL DEVICES CLASS I, AND CLASS II, FOR DENTAL USE ONLY.DISPOSITIFS MÉDICAUX CLASSE I ET CLASSE II,POUR USAGE DENTAIRE SEULEMENT SEPTEMBRE 2014 – REV 2
WWW.THOMAS-DENTALTOOLS.COM LEARN MORE ON / PLUS D’INFORMATIONS SUR
Juill
et 2
014-
rev0
FFDMPNEUMAT
MADE INFRANCE
FFDM PNEUMAT 78/80, Avenue de la Prospective18020 Bourges Cedex (France)
Tél. +33 (0)2 48 23 27 37 • Fax : +33 (0)1 46 52 72 90E-mail : [email protected]
Norm : EN ISO 1797 NF EN ISO 13485
NiTiShaper
0459
Continuous rotationRotation continue NiTi System
edex (France)0)1 46 52 72 90pneumat.com
Norm : EN ISO 1797 NF EN ISO 13485
NNiTi Sys
Medical device class IIa Dispositif médical de classe IIa
Smart design for a safe preparation
Un design intelligent pour une préparation sûre
See our NitiShaper systemfor the preparation in continuousrotation.
Voir notre système NitiShaperpour la préparation en rotationcontinue.
1
HAND INSTRUMENTSINSTRUMENTS À MAIN
ENGINE DRIVEN INSTRUMENTSINSTRUMENTS MECANISES
WWW.THOMAS-DENTALTOOLS.COM
ENDODONTIC INSTRUMENTS
REAMER / BROCHE
Length / Longueur : 21, 25, 28, 31 mmRef ISO : 006 1 140
Ass. :15/40 - 45/80 - 90/140Packaging : x 6
6 CANAL PROBE
Length / Longueur : Longueur: 21, 25 mmRef ISO : 012
Packaging : x 6
2 K-FILE / LIME K
Length / Longueur : 21, 25, 28, 31 mmRef ISO : 006 1 140
Ass. :15/40 - 45/80 - 90/140Packaging : x 6
7 BARBED BROACH / TIRE NERF
Length / Longueur : 21, 25 mmRef ISO : 020 1 040
Ass. : 25/40Packaging : x 6
5 K-FILE « T-FLEX » / LIME K « T-FLEX »
Length / Longueur : 21, 25, 28, 31 mmRef ISO : 015 1 040
Ass. : 15/40Packaging : x 6
Recommended for curved root canalRecommandé pour le traitement des canaux compliqués
Recommended for curved root canalRecommandé pour le traitement des canaux compliqués
8 HELIXOFILE
Length / Longueur : 21, 25 mmRef ISO : 015 1 080
Ass. : 15/40 - 45/80Packaging : x 6
Comfortable and easy to grip handle. Easy identification of instruments through ISO colorcode, number and ISO symbol. Supplied with or without silicone stopper.
Manche ergonomique au code couleur et numérotation ISO. Symbole ISO identifiant le type d’instrument. Livrable avec ou sans rondelle stop.
Handle according to the ISO norm 1797.Used by connecting with a contre angle.
Manche suivant norme ISO 1797.Utilisé en se connectant avec un contreangle.
B2 LINE / GAMME B2
4 H-FILE / RACLEUR
Length / Longueur : 21, 25, 28, 31 mmRef ISO : 008 1 140
Ass. :15/40 - 45/80 - 90/140Packaging : x 6
10 FINGER PLUGGER / FOULOIR BOUT PLAT
Length / Longueur : 21, 25 mmRef ISO : 015 1 080
Ass. :15/40 - 45/80Packaging : x 6
3 H-FILE FLEX / RACLEUR FLEX
Length / Longueur : 21, 25, 28, 31 mmRef ISO : 010 1 080
Ass. :15/40 - 45/80 Packaging : x 6
9 FINGER SPREADER / FOULOIR BOUT POINTU
Length / Longueur : 21, 25 mmRef ISO : 1 1 6
Ass. : 1/6 (15/40)Packaging : x 6
1 ENGINE REAMER / BROCHE FORET
Length / Longueur : 21, 25, 28, 31 mmRef ISO : 008 1 140
Ass. :15/40 - 45/80 - 90/140Packaging : x 6
2 ENGINE K-FILE / LIME K MÉCANISÉE
Length / Longueur : 21, 25, 28, 31 mmRef ISO : 006 1 140
Ass. :15/40 - 45/80 - 90/140Packaging : x 6
3 ENGINE H-FILE / RACLEUR MÉCANISÉ
Length / Longueur : 21, 25, 28, 31 mmRef ISO : 008 1 080
Ass. :15/40 - 45/80Packaging : x 6
4 ENGINE BROACH / ALÉSOIR
Length / Longueur : 21, 25 mmRef ISO : 025 1 050
Ass. : 25/50Packaging : x 6
5 ENGINE HELIXOFILE / HELIXOFILE MÉCANISÉ
Length / Longueur : 21, 25 mmRef ISO : 015 1 080
Ass. :15/40- 45/80Packaging : x 6
2 “DYNA” PASTE FILLER / BOURRE-PÂTE “DYNA”
Length / Longueur : 21, 25 mmRef ISO : 025 1 040
Ass. : 25/40Packaging : x 4 / x 6
1 LENTULO PASTE FILLER / BOURRE-PÂTE LENTULO
Length / Longueur : 17, 21, 25, 29 mmRef ISO : 025 1 040
Ass. : 25/40Packaging : x 4 / x 6
2 GATES
Length / Longueur : 28, 32 mmRef ISO : 1, 2, 3, 4, 5, 6
Ass. : 1/6Packaging : x 6
1 PEESO
Length / Longueur : 28, 32 mmRef ISO : 1, 2, 3, 4, 5, 6
Ass. : 1/6Packaging : x 6
6 ENGINE H-FILE FLEXRACLEUR FLEX MÉCANISÉ
Length / Longueur : 21, 25, 28, 31 mmRef ISO : 0008 1 080
Ass. : 15/40 - 45/80Packaging : x 6
Presence of a spring to decrease the risk of breakagePrésence d’un ressort pour réduire le risque de fracture
FILLING INSTRUMENTS / OBTURATION
ROOT CANAL DRILL / ELARGISSEUR
0459MEDICAL DEVICES CLASS I,DISPOSITIFS MÉDICAUX CLASSE I MEDICAL DEVICES CLASS II,DISPOSITIFS MÉDICAUX CLASSE II
REAMING / ALESAGE REAMING / ALESAGE FILLING INSTRUMENTS / OBTURATION
Please consult us for the canal finder instrumentsVeuillez nous consulter pour les instruments canal Finder
Please consult our website to check the ISO numbers availableVeuillez consulter notre site internet pour vérifier les numéros ISO disponibles
Available in contra angle versionDisponible en version mécanisée
3 “THOMAS SPECIAL” PASTE FILLERBOURRE-PÂTE “THOMAS SPÉCIAL”
Length / Longueur : 17, 21, 25, 29 mmRef ISO : 025 1 040
Ass. : 25/40Packaging : x 4 / x 6
Presence of a spring to decrease the risk of breakagePrésence d’un ressort pour réduire le risque de fracture
Please consult us for the cement fillersVeuillez nous consulter pour les bourres ciment