5
DALIC, B.P. 90139, 35501 VITRE CEDEX, FRANCE [email protected] 12.01.2007 Codes: 10034, DPR 5004, document code: FDS 10034 1/5 SAFETY DATA SHEET I - IDENTIFICATION OF THE SUBSTANCE / PREPARATION AND OF THE COMPANY / UNDERTAKING IDENTIFICATION OF THE SUBSTANCE OR PREPARATION ATTAQUE N°4 or ACTIVATOR XP (code 10034) ACTIVATOR / ETCH N°4 (code: DPR 5004) USE OF THE SUBSTANCE / PREPARATIONS These solutions are used at ambient temperature with a brush plating tool to etch locally some substrates (stainless steel, nickel and nickel alloys: inconels, monels, etc.). The surfaces are firstly etched with reverse polarity; then powerful depassivation carried out with normal polarity ensures adhesion of the deposit. A correct treatment causes a surface dissolution of approximately 7 μm. The specificity of the brush process is it can be applied locally, just where it is necessary, without immersion of the part. Thus, only small quantities of solutions are stored or used. COMPANY / UNDERTAKING IDENTIFICATION DALIC - ZI de Plagué - 41, Rue des Eaux, BP. 90139 - 35501 VITRE CEDEX, France Manufacturer and Seller – Tel.: (33) 2.99.75.36.99 - Fax: (33) 2.99.74.49.31 FRENCH EMERGENCY TELEPHONE INRS / Orfila, tel.: (33) 1.45.42.59.59 ________________________________________________________________________________________________ II - COMPOSITION / INFORMATION ON INGREDIENTS COMPONENTS OR IMPURITIES CONTRIBUTING TO THE HAZARDS (according to 1999/45/EC and 67/548/EC) Substances present in concentrations higher than the minimal level of danger: NO. Substances present in concentrations lower than the minimal level of danger (if 1%): YES. Regulated substance HCl (19 th ) Hydrochloric acid EC index N°: 017-002-01-X CAS N°: - EINECS N°: 231-595-7 Classification of the pure substance C R34 Xi R37 S phrases (1/2)-26-45 Classification of the substance according to its concentration (in %) 25 % C R34-37 10-25 % Xi R36/37/38 Concentration range in the preparations < 10 % Substances with the R33 phrase (if 1%) or with the R64 phrase (if 1%) or sensitising substances (if 0.1%): NO. OTHER SUBSTANCES WITH WORKPLACE EXPOSURE LIMITS: NO. OTHER INFORMATION: contains also not classified salts. ________________________________________________________________________________________________ III – HAZARDS IDENTIFICATION CHEMICAL NATURE Acidic aqueous solutions containing not specified chemicals or specified products below the regulated levels, for example less than 10% hydrochloric acid. PRODUCT CLASSIFICATION ACCORDING TO 1999/45/EC and 67/548/EC Preparations not classified as dangerous with regard to these directives in reason of their low content in acids and other components. MAIN HAZARDS Adverse physicochemical effects - Fire or explosion: these products are not classified as flammable or explosive. Adverse effects on health Due to the pH (less than 1), may cause damage in case of contact with eyes or skin if washing with water is not immediately achieved, also in case of ingestion or by inhalation under abnormal conditions of use.

description

Activator XP Material Safety Data Sheet for DALIC Selective Plating

Transcript of FDA 10034

Page 1: FDA 10034

DALIC, B.P. 90139, 35501 VITRE CEDEX, FRANCE [email protected] 12.01.2007Codes: 10034, DPR 5004, document code: FDS 10034 1/5

SAFETY DATA SHEET

I - IDENTIFICATION OF THE SUBSTANCE / PREPARATION AND OF THE COMPANY / UNDERTAKING

IDENTIFICATION OF THE SUBSTANCE OR PREPARATION

ATTAQUE N°4 or ACTIVATOR XP (code 10034) ACTIVATOR / ETCH N°4 (code: DPR 5004)

USE OF THE SUBSTANCE / PREPARATIONS These solutions are used at ambient temperature with a brush plating tool to etch locally some substrates (stainless steel, nickel and nickel alloys: inconels, monels, etc.). The surfaces are firstly etched with reverse polarity; then powerful depassivation carried out with normal polarity ensures adhesion of the deposit. A correct treatment causes a surface dissolution of approximately 7 µm. The specificity of the brush process is it can be applied locally, just where it is necessary, without immersion of the part. Thus, only small quantities of solutions are stored or used.

COMPANY / UNDERTAKING IDENTIFICATION DALIC - ZI de Plagué - 41, Rue des Eaux, BP. 90139 - 35501 VITRE CEDEX, France Manufacturer and Seller – Tel.: (33) 2.99.75.36.99 - Fax: (33) 2.99.74.49.31 FRENCH EMERGENCY TELEPHONE INRS / Orfila, tel.: (33) 1.45.42.59.59 ________________________________________________________________________________________________

II - COMPOSITION / INFORMATION ON INGREDIENTS

COMPONENTS OR IMPURITIES CONTRIBUTING TO THE HAZARDS (according to 1999/45/EC and 67/548/EC) Substances present in concentrations higher than the minimal level of danger: NO. Substances present in concentrations lower than the minimal level of danger (if ≥ 1%): YES.

Regulated substance

HCl (19th) Hydrochloric acid

EC index N°: 017-002-01-X CAS N°: - EINECS N°: 231-595-7

Classification of the pure substance

C R34 Xi R37

S phrases (1/2)-26-45 Classification of the

substance according to its concentration (in %)

≥ 25 % ⇒ C R34-37 10-25 % ⇒ Xi R36/37/38

Concentration range in the preparations < 10 %

Substances with the R33 phrase (if ≥ 1%) or with the R64 phrase (if ≥ 1%) or sensitising substances (if ≥ 0.1%): NO. OTHER SUBSTANCES WITH WORKPLACE EXPOSURE LIMITS: NO. OTHER INFORMATION: contains also not classified salts. ________________________________________________________________________________________________

III – HAZARDS IDENTIFICATION

CHEMICAL NATURE Acidic aqueous solutions containing not specified chemicals or specified products below the regulated levels, for example less than 10% hydrochloric acid. PRODUCT CLASSIFICATION ACCORDING TO 1999/45/EC and 67/548/EC Preparations not classified as dangerous with regard to these directives in reason of their low content in acids and other components. MAIN HAZARDS Adverse physicochemical effects - Fire or explosion: these products are not classified as flammable or explosive. Adverse effects on health Due to the pH (less than 1), may cause damage in case of contact with eyes or skin if washing with water is not immediately achieved, also in case of ingestion or by inhalation under abnormal conditions of use.

Page 2: FDA 10034

DALIC, B.P. 90139, 35501 VITRE CEDEX, FRANCE [email protected] 12.01.2007

Codes: 10034, DPR 5004, Safety Data Sheet, document code: FDS 10034 2/5

Effects on the environment These preparations are not classified as dangerous for the environment providing that the recommendations of the section XIII relative to disposal as well as the national or local provisions are followed.

Refer also to the paragraphs XI, XIII and XV. ________________________________________________________________________________________________

IV - FIRST AID MEASURES

CONTACT WITH SKIN Take off contaminated clothing and shoes. Wash immediately with plenty of water.

CONTACT WITH EYES Rinse immediately with plenty of water for approximately 15 minutes. In case of pain, redness, local oedema or visual discomfort, call an ophthalmologist.

INHALATION Theoretically, not applicable. Under abnormal conditions of use causing considerable inhalation, remove the casualty from the contaminated area, let him take a rest in a well-ventilated room and seek medical advice. Following the inhaled quantity, a delayed pulmonary oedema may appear and a clinical and radiological supervision may be necessary.

INGESTION Don’t try to induce vomiting. Do not give anything to drink. Call immediately the medical service to transfer to hospital. Complications may appear later. A clinical and biological supervision and a treatment may be necessary.

PROTECTION OF THE FIRST-AIDERS According to the situation, wear gloves, clothes and protective shoes, glasses or masks … ________________________________________________________________________________________________

V - FIRE-FIGHTING MEASURES

SUITABLE EXTINGUISHING MEDIA Water spray to blow the vapours and sprays of hydrochloric acid back down. Sodium carbonate or slaked lime to neutralize the acid. Dry ice, powders and chemical foams. EXTINGUISHING MEDIA WHICH MUST NOT BE USED No contraindication.

SPECIFIC HAZARDS Hydrogen chloride (gas) and the other substances that remain after water evaporation are thermally very stable even above 1000°C. The dissociation of HCl gas in hydrogen and chlorine is higher than 1% above 2230°C. HCl gas is heavier than air. Dangerous thermal decomposition products: pungent and toxic fumes containing in particular oxides, hydrochloric gas, chlorides, hydrogen and chlorine according to the temperature.

PROTECTION OF THE FIRE-FIGHTERS Because of the toxicity of the substances that are produced during thermal decomposition, use approved self-contained breathing equipment and protective clothing in case of intervention. ________________________________________________________________________________________________

VI - ACCIDENTAL RELEASE MEASURES

PERSONAL PRECAUTIONS Avoid contact with skin and eyes: wear at least gloves, glasses and a FFP3 mask in case of sprays or vapours. In case of contact, wash thoroughly with water.

ENVIRONMENTAL PRECAUTIONS Do not allow the product to be thrown away without neutralization. Recover as much as possible for processing within the firm or by an approved centre.

METHODS FOR CLEANING UP With water to remove all non-recoverable product. Before throwing rinsing water, check the pH is between 5.5 and 8.5. ________________________________________________________________________________________________

VII - HANDLING AND STORAGE

HANDLING Use as supplied. Close containers (in PE) tightly after use with the original cap. Do not re-use containers with another product.

STORAGE Store on a spill-retaining vat away from alkaline or oxidizing products, sulphuric acid, metals and cyanides. Keep in original containers only, between 5 and 30°C if possible away from sun-light. The maximum recommended shelf life is three years from the date of manufacture under normal conditions of storage. ________________________________________________________________________________________________

Page 3: FDA 10034

DALIC, B.P. 90139, 35501 VITRE CEDEX, FRANCE [email protected] 12.01.2007

Codes: 10034, DPR 5004, Safety Data Sheet, document code: FDS 10034 3/5

VIII - EXPOSURE CONTROLS / PERSONAL PROTECTION

EXPOSURE CONTROLS TECHNICAL MEASURES No drinking, eating or smoking on the workplace. Maintain the premises and the workplace in a perfect state of cleanliness, and clean them frequently.

EXPOSURE LIMIT VALUES IN AIR Anhydrous hydrochloric acid France: decision of 30 June 2004 Limit value = 7.6 mg/m3

Directive 2000/39/EC Average value = 8 mg/m3 Limit value = 15 mg/m3

Directive 2006/15/EC -

PERSONAL PROTECTION Provide a shower, a powerful tap and sink unit, an eye basin in the vicinity of the work place and a protective breathing mask for emergency interventions. - Respiratory protection: during brush electrolysis, provide an inhaling of the sprays / vapours where they are created and extraction out of the premises and if insufficient, wear a filtering B2P3 cartridge according to EN 405:2002 standard. - Hand protection: wear imperatively gloves (in latex, nitrile or neoprene for example). - Eye protection: wear imperatively glasses with lateral protections or a facial screen. Do not wear contact lenses. - Skin protection: wear overalls and safety shoes. ________________________________________________________________________________________________

IX - PHYSICAL AND CHEMICAL PROPERTIES

- Appearance: colourless liquid. - Odour: odourless. - pH: <1. - Relative density: 1.11. - Solubility: miscible in water in all proportions. - Boiling point: approximately 100°C. - Crystallisation / melting point: -13°C. - Flammability: nil. - Oxidising properties: nil. - Danger of fire or explosion: no, but these products can react vigorously with some compounds (see section X). In

case of reaction with metals, there is also hydrogen evolution (flammable and explosive gas in some concentrations in air).

- Other properties: not applicable. ________________________________________________________________________________________________

X - STABILITY AND REACTIVITY

STABILITY Good at ambient temperature with water evaporation for only risk. Good in humidity and light. CONDITIONS TO AVOID High temperatures. MATERIALS TO AVOID Notably bases, oxidizers, organic products, metals, halogenated products, perchloric acid, sulphuric acid, oleum, cyanides… HAZARDOUS DECOMPOSITION PRODUCTS Toxic and pungent fumes containing in particular oxides, hydrochloric gas, chlorides, hydrogen and chlorine according to the temperature or to the reactions. ________________________________________________________________________________________________

XI - TOXICOLOGICAL INFORMATION

No data are available regarding the preparations themselves. The evaluation of health hazards has been realised thanks to directives 67/548/EC, 1999/45/EC and bibliographical data. SKIN Little irritating but the pH is lower than 1. The effect will depend on the applied quantity and on the length of contact.

EYE MUCOSA Is not classified as irritating; however following the length of contact and the applied quantity, may cause severe irritations and even severe caustic lesions if decontamination with water is not quickly achieved.

RESPIRATORY SYSTEM May be strongly irritating if the electrolysis is performed with a bad inhaling of the sprays above the workplace.

IN CASE OF INGESTION Pains and vomiting are possible as well as burns and complications in the following days.

Page 4: FDA 10034

DALIC, B.P. 90139, 35501 VITRE CEDEX, FRANCE [email protected] 12.01.2007

Codes: 10034, DPR 5004, Safety Data Sheet, document code: FDS 10034 4/5

INDUSTRIAL DISEASES: none (in FRANCE). ________________________________________________________________________________________________

XII - ECOLOGICAL INFORMATION

There are no ecological data on the preparations themselves. ECOTOXICITY Bibliographic data concerning hydrochloric acid: FISHES - CL50 (24 h) = 369 mg/L, DAPHNIAS - CE50 (24 h) = 213 mg/L, ALGAE - CI50 (120 h) = 25.5 mg/L. Immediate ionization in aquatic environment. Harmful to the aquatic organisms because of the acidic pH. MOBILITY - PERSISTENCE AND DEGRADABILITY - BIOACCUMULATIVE POTENTIAL – OTHER ADVERSE EFFECTS High mobility and persistence under ionic state. The involved substances are not bio accumulative. According to the applicable EC directives, it is not appropriate to apply the″N″ symbol ″DANGEROUS FOR THE ENVIRONMENT″ to these preparations. ________________________________________________________________________________________________

XIII - DISPOSAL CONSIDERATIONS

These products and water used for rinsing must not be thrown away notably because of their acidity and their content in metals after use. They must be processed within the firm or destroyed by an approved organization. Contaminated packaging if not re-used with the same product is also special waste to be sent to an approved organization for recycling or disposal. Classification according to the commission directive 2000/532/EC of 3 May 2000 and its modifications (in particular 2001/118/EC, OJ L47). Use the mandatory documents to follow-up the waste products.

06 03 13* or 11 01 05*

Solid salts and solutions containing heavy metals Pickling acids

11 01 11* Aqueous rinsing liquids containing dangerous substances 15 01 10* Packaging containing residues of or contaminated by

dangerous substances As the volume of rinsing water is small, it can be added to the waste solutions. NOTE: in addition to the community provisions, it can be specific legislative and administrative, national or local provisions on this topic. ________________________________________________________________________________________________

XIV - TRANSPORT INFORMATION

A.D.R. (road transport) ″Hydrochloric acid″, class 8, classification code C1, packaging group III, hazard label model 8, restricted quantities LQ19, hazard identification n° 80, material identification n° 1789.

I.M.D.G. (sea transport) ″Hydrochloric acid″, UN N° 1789, class 8, packaging group III, subsidiary risk label: not applicable, restricted quantities 5L, stowing and separation: category C, safety sheets F-A, S-B.

I.A.T.A. (air transport) ″Hydrochloric acid″, UN N° 1789, class 8, subsidiary risk: not applicable, risk label: CORROSIVE, packaging group III, Passenger and Cargo aircraft: packaging instructions 819, maximum quantity per package: 5L, Cargo aircraft only: packaging instructions 821, maximum quantity per package: 60L, instruction IDC 8L. ________________________________________________________________________________________________

XV - REGULATORY INFORMATION

This safety data sheet has been established in accordance with Commission Directive 91/155/EC of 5 March 1991 modified by the directive 2001/58/EC of 27 July 2001. It complies with standards NF T 01-102 and ISO 11014-1. The preparation labelling has been established in compliance with the directive 67/548/EC (until the 29th adaptation: directive 2004/73/EC of 29 April 2004) and the directive 1999/45/EC modified by the directive 2001/60/EC of 7 August 2001. EC LABELLING: Is not classified but contains at least one dangerous compound with a non regulated concentration (with regard to the 67/548/EC directive until the 29th modification). A safety data sheet is available. Aqueous acidic preparation containing, in particular, less than 10 % hydrochloric acid. S26: in case of contact with eyes, rinse immediately with plenty of water and seek medical advice. S37/39: wear suitable gloves and eye/face protection.

Page 5: FDA 10034

DALIC, B.P. 90139, 35501 VITRE CEDEX, FRANCE [email protected] 12.01.2007

Codes: 10034, DPR 5004, Safety Data Sheet, document code: FDS 10034 5/5

HEALTH SURVEILLANCE Council Directive 98/24/EC of 7 April 1998 on the protection of the health and safety of workers from the risks related to chemical agents at work An appropriate health surveillance of workers must be carried out according to the risk. For each worker who undergoes this health surveillance, individual health and exposure records are to be made and kept up-to-date.

Other paragraphs in the French version of this safety data sheet summarize French rules regarding: • professional diseases, • health surveillance, • administrative declarations and rules, • environment laws regarding rinsing water treatment.

Refer also to specific legislative and administrative, national or local provisions on these topics. Additional information is provided in paragraphs VIII, XI, XII, XIII and XIV. ________________________________________________________________________________________________

XVI - OTHER INFORMATION

RESTRICTION OF USE For industrial use only.

R PHRASES OF THE PURE COMPONENTS LISTED IN SECTION 2 R34: causes burns. R37: irritating to respiratory system.

R PHRASES OF THE PREPARATION ACCORDING TO THE SECTIONS 3 AND 15 None.

BIBLIOGRAPHIC REFERENCES European directives, INRS files, safety data sheets of the components established by their manufacturers or distributors, information of European Office of the chemical substances (ECB).

MODIFICATIONS Updating in relation to directives 2001/58/EC, 2001/59/EC, 2001/60/EC and 2004/73/EC. General presentation. Revised paragraphs: all.

OTHER INFORMATION This sheet is provided to complement, not replace, the user instructions. Information contained herein is bona fide and based on current knowledge relating to the product on the date of publication. Furthermore, the attention of the user is drawn to the risks which may be incurred when the product is used for purposes other than those for which it is designed. Information provided herein relates to this product only; it cannot take account of every situation which may arise at every work place. This safety data sheet therefore represents only a part of the information required for establishing a safety programme. Under no circumstances does this sheet dispense the user from the need to know and to apply all of the regulations governing its activity, which are not all necessarily quoted herein in an exhaustive manner. ________________________________________________________________________________________________