“Arc Fault Detection Device (AFDD) is an innovative automated equipment for prevention of fires from arcing in electrical circuits and electrical installations”

Transcript of Fault Detection Device (AFDD) is an innovative automated...

Page 1: Fault Detection Device (AFDD) is an innovative automated ...rustrade.org.uk/rus/wp-content/uploads/Ecolight.pdf · used for overcurrent protection (hereinafter ACB, see GOST R 50345-99),

“Arc Fault Detection Device (AFDD) is an innovative

automated equipment for prevention of fires from

arcing in electrical circuits and electrical installations”

Page 2: Fault Detection Device (AFDD) is an innovative automated ...rustrade.org.uk/rus/wp-content/uploads/Ecolight.pdf · used for overcurrent protection (hereinafter ACB, see GOST R 50345-99),

Ltd. ECOLIGHT

LLC ECOLIGHT is an innovative Russian manufacturer of LED lighting

fixtures under ECOLIGHT brand.

Since 2015, the company has developed and launched a new Arc Fault

Detection Device (AFDD). The latest development will reduce the number of

fires due to faults of electrical mains by more than 2 times.

The main advantages of ECOLIGHT products are high quality, reliability and

affordability.

2

Page 3: Fault Detection Device (AFDD) is an innovative automated ...rustrade.org.uk/rus/wp-content/uploads/Ecolight.pdf · used for overcurrent protection (hereinafter ACB, see GOST R 50345-99),

Fire statistics

In 2016, there were 139,700 fires in Russia, which killed 8,760 people, injured 9,909 people, and caused property damage for 14,324 bln rub.

According to FSRI of the Ministry of Emergency of Russia, fires from electrical equipment countrywide include: • 26%, at the enterprises of certain ministries and authorities; • Share of fires from electrical installations reaches 38%; • In residential buildings - 32%; • In private houses up to 70% of fires is caused by electrical installations.

Causes of fires as exemplified by Germany

(2016) Statistics of causes of electricity mains failures as

exemplified by Denmark for 2016

3

Lightning strike

Electrical energy

Explosion

Arson

Hot works

Human factor

Open fire

Self-ignition

Overheating

Other/unknown

Operational failure Loose connection Ageing Material defects Damage by rodents Insulation fault Damages and moisture attack

Page 4: Fault Detection Device (AFDD) is an innovative automated ...rustrade.org.uk/rus/wp-content/uploads/Ecolight.pdf · used for overcurrent protection (hereinafter ACB, see GOST R 50345-99),

Main causes of fires in electric systems and mechanisms

1. Arcing at big transition resistance (BTR) as the main current cause of fires in electrical mains.

2. Inflammation from parallel arcing.

4

Page 5: Fault Detection Device (AFDD) is an innovative automated ...rustrade.org.uk/rus/wp-content/uploads/Ecolight.pdf · used for overcurrent protection (hereinafter ACB, see GOST R 50345-99),

Arc Fault Detection Device (AFDD)

• AFDD is in fact the third stage of development of electrical mains protection devices, following automatic circuit breakers and RCDs.

• It is installed in the distribution board on DIN-rail. • It is equipped with AFDD-I control device designed to configure and verify

functioning at the places of operation. • AFDDs identify arc in the protected circuit and automatically disconnect it from the mains.

5

Page 6: Fault Detection Device (AFDD) is an innovative automated ...rustrade.org.uk/rus/wp-content/uploads/Ecolight.pdf · used for overcurrent protection (hereinafter ACB, see GOST R 50345-99),

Standard equipment for protection of electrical circuits

To protect electrical line the automatic circuit breakers are used for overcurrent protection (hereinafter ACB, see GOST R 50345-99), as well as circuit breakers operated by differential current (RCD, see GOST R IEC 60755—2012).

6

Protection device

Type of arcing

Series

(BTR – poor contact)

Parallel

Phase - neutral

Parallel

Phase - ground

Automatic

Circuit

breaker

Doesn’t detect at all May actuate too late (with a

limited short-circuit current)

May actuate too late (with a

limited short-circuit current)

RCD Doesn’t detect at all Doesn’t detect at all May not detect (under pulsed

nature of arcing)

AFDD Disconnects the mains Disconnects the mains Disconnects the mains

Reaction of electrical mains protection devices on various types of arcing

Page 7: Fault Detection Device (AFDD) is an innovative automated ...rustrade.org.uk/rus/wp-content/uploads/Ecolight.pdf · used for overcurrent protection (hereinafter ACB, see GOST R 50345-99),

Энергоэффективная продукция «ЭКОЛАЙТ» AFDDs were successfully tested and are recommended for use, which is certified by the following expert opinions: • No.137/15 dated November 20, 2015, issued by FSBEI HPE MSCU Institute of

Integrated Safety in Construction; • No.35/81-2015 dated September 15, 2015, issued by FSBEI HPE State Fire-

Fighting Service Academy of the Ministry of Emergency Situations of Russia AFDD has received a Certificate No. TC RU C-RU.ME68.B. 00072 of compliance with the requirements of the Technical regulations of the Customs union TR CU 004/2011 “Concerning the safety of low-voltage equipment” and TR CU 020/2011 “Electromagnetic compatibility of technical means.”

Licenses, patents

Patents:

7

Page 8: Fault Detection Device (AFDD) is an innovative automated ...rustrade.org.uk/rus/wp-content/uploads/Ecolight.pdf · used for overcurrent protection (hereinafter ACB, see GOST R 50345-99),

Expected benefits from the services

Comparison of technical and economic characteristics of AFDDs developed by LLC ECOLIGHT with the products of the main competitors

Parameters Products

Technical and economic characteristics of the product Siemens 5SM6

Schneider Electric

A9FDD225

AFDD manufactured by

ECOLIGHT company

Rated maximum current, A 16 25 63

Availability on the Russian market

Delivery under the order, the

delivery time is three (3) months

Not supplied

Start-up of mass production is

planned for 2018

Approximate price €130 - €65

8

Page 9: Fault Detection Device (AFDD) is an innovative automated ...rustrade.org.uk/rus/wp-content/uploads/Ecolight.pdf · used for overcurrent protection (hereinafter ACB, see GOST R 50345-99),

Comparison of technical and economic characteristics of major competitors

9

Manufacturer Products Type

execution Rated current,

A

Size on the DIN-rail,

у.е.

Cause indication triggering

Testing (manual / automatic)

Average price (without shipping and customs fees)

Additional Functions / Note

Ecolight AFDD-С1-63 Single 63 2 Continuous Automatic 65 EUR

Overvoltage trip with adjustable value of 260-290 V

Availability of a means of monitoring the operation area

Siemens (OEZ)

5SM6011-1 Modular 16 2 After restarting Automatic 93,58 EUR 1. Tching off at a voltage greater than 275V 2. AV connections by bundling with Siemens 5SY30 or 5SY60 MCB 5SM6014-2 Modular 40 2 After restarting Automatic 109,44 EUR

5SM6021-1 Modular 16 3 After restarting Automatic 98,87 EUR 1. Switching off at a voltage greater than 275V

2. AV connections by bundling with Siemens 5SY, 5SL MCB or RCD connection when bundled with Siemens 5SU RCBO 5SM6024-2 Modular 40 3 After restarting Automatic 113,23 EUR

Schneider Electic

A9FDB610 Single 10 2 No Manual 93,05 EUR 1. Integrated AB, type C 2. Trip at a voltage greater than 400V, tripping time of 200ms

A9FDB616 Single 16 2 No Manual 90,28 EUR

ABB

S-ARC1 B10 Single 10 2 After restarting Manual

+Automatic 112,22 EUR

1. Integrated AB, type B 2. Switching off at a voltage greater than 275V

3. With a negative result of the self-test, the device flashes red-green, but does not turn off, and must be checked by a manual test. This contradicts clause 8.17 of standard 62606 and without a constant

visual control of the indication may lead to a lack of reaction to the arc breakdown

S-ARC1 B16 Single 16 2 After restarting Manual

+Automatic 113,15 EUR

Hager ARC910D Single 10 2 No Manual 110,81 EUR 1. Switching off at a voltage greater than 275V, time of switching-off

200ms 2. Integrated AB, type B ARC916D Single 16 2 No Manual 104,29 EUR

Eaton (Doepke, Schrack Technik)

AFDD-10/2/B/003-Li/A

Single 10 3 No Automatic 125,1 EUR 1. Integrated AB, type B 2. Switching off at a voltage greater than 270V

3. Integrated RCD, current difference 0,03A 4. Overheating control

AFDD-16/2/B/003-Li/A

Single 16 3 No Automatic 119,69 EUR

Page 10: Fault Detection Device (AFDD) is an innovative automated ...rustrade.org.uk/rus/wp-content/uploads/Ecolight.pdf · used for overcurrent protection (hereinafter ACB, see GOST R 50345-99),

Project support

10

In July 2017, the working group of the Expert Council of the Agency for Strategic Initiatives (ASI) reviewed and approved for support the business project "Development of production of automated spark protection devices (AFDD) for preventing fires in electrical networks and electrical installations". In November 2016, the State Budgetary Institution of Moscow, the Moscow City Innovation Agency, decided to include the products of ECOLIGHT Ltd. in the list of innovative, high-tech products and technologies. The AFDD project is a participant in the Skolkovo Innovation Center.

Page 11: Fault Detection Device (AFDD) is an innovative automated ...rustrade.org.uk/rus/wp-content/uploads/Ecolight.pdf · used for overcurrent protection (hereinafter ACB, see GOST R 50345-99),

Benefits from introduction

For citizens For city government

Prevention of fires, which may cause serious physical and property damage

Affordable price AFDD is an import substituting and

competitive product in Russia

Increase in jobs Increase in the tax base of Moscow

11