Fan Ventillation Calculations-HVAC
Transcript of Fan Ventillation Calculations-HVAC
-
7/23/2019 Fan Ventillation Calculations-HVAC
1/92
Ventilation Fan Catalogue
Proven, Reliable Bathroom Ventilation Solutions
-
7/23/2019 Fan Ventillation Calculations-HVAC
2/92
Externally Mounted Fans
Heat n Light 2 (excludes fan)
Shower Fan Low Prole 150
NEW
NEW
PROVEN: Trusted Locally, Proven Globally.
RELIABLE: Durable Ball Bearing Motors
with a 5 Year Warranty.SOLUTIONS: A Complete Range of Fans,
Ducting and Accessories.
Thomas & Betts are proud to be
the distributor of the MANROSErange of ventilation fans.
MANROSE offers an extensive range of extraction
fans suitable for bathrooms,
en-suites, laundries and kitchens.
National Support Centre
Phone: 1300 666 595
Fax: 1300 666 594
Email: [email protected]
www.manrose.com.au
Suite 3, Level 7, 3 Rider Boulevard
Rhodes NSW 2138
Western Australia
Unit 2, 22 Hammond Rd
Cockburn Central WA 6164
Victoria
2/13-15 Brough St
Springvale VIC 3171
Tasmania
Electrical Agencies
4 Linear CourtMoonah TAS 7009
South Australia
86A Richmond Rd
Keswick SA 5035
Queensland
26 Turbo Drive
Cooparoo QLD 4151
Newcastle
Nick Webb Agencies
Unit 5, 21 Babilla CloseBereseld NSW 2322
-
7/23/2019 Fan Ventillation Calculations-HVAC
3/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au
PUB0385 iss02 06/11
Contents
VENTILATION SELECTION/REGULATIONS
3 - 9
SELECTION CHART 10 - 11
VENTILATION INTRODUCTION 2
VENTILATION FANS 12 - 30
Wall Ceiling Fans 12 - 14
Thru Wall Fan Kit 15 - 16
Window Fans 17
Heat/Fan/Light Units 18
In-Line Fan Kits 19 - 21
In-Line Fans 22 - 24
Wall Mounted Fans 25
Thru Roo Fans 26
Specialised Fans 27 - 28
Fan Accessories 29 - 30
DUCT & FITTINGS 31 - 45
Ducting 31 - 33
Duct Fittings 34 - 37
Grilles & Diusers 38 - 42
Thru Roo Cowls/Kits 43
Rangehood Ducting Kits 44
Duct Accessories 45
HEAT TRANSFER 46 - 49
TECHNICAL DATA 50 - 81
INDEX 82 - 84
NOTES 85 - 87
-
7/23/2019 Fan Ventillation Calculations-HVAC
4/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au2
1
Ventilation Introduction
Thomas & Betts are proud to be the distributor o theMANROSE range o ventilation ans.
Thomas and Betts have been supplying the electrical wholesale market orover 35 years and credit their success to outstanding delivery and customerservice capabilities and are proud o their strong, long-standing partnerships.They represent the highest quality and most innovative products available.
The MANROSE brand is known or proven, reliable solutions withan evolving product range to meet the demands o the market.Thomas & Betts and MANROSE have a strong relationship, which has seenventilation products developed speciically or the Australian market witheatures demanded by the customer.
Examples o this are developments in an reliability; as an perormance is acritical actor, all MANROSE branded products are supplied with ball bearingmotors to ensure these ans perorm consistently over many years. As aresult highly demanded MANROSE ans are supported by a 5 year warranty.(as marked throughout the catalogue)
Within the MANROSE range there are several models available; rom a Classicmodel which oers trusted perormance to the Pro-Series models with higherspeciications. The Pro-Series brand includes products that oer installationadvantages and eatures to the contractor, as well as sought ater aestheticsdemanded by the consumer. The policy o ongoing investment in productdevelopment has been a key orce in driving the MANROSE brand to theoreront o the ventilation market.
MANROSE have an extraction solution or every application. Continualdevelopment and innovation ensures that uture market demands are not onlymet but exceeded!
Proven Reliable Ventilation Solutions
CLASSIC
-
7/23/2019 Fan Ventillation Calculations-HVAC
5/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au 3
New building materials and construction methods are eectively resulting in waterproo buildings. They trapmoisture inside just as eectively as they keep moisture out.
Open doors and windows provide air circulation and ventilation but security considerations mean that we areincreasingly less likely to use this option. Houses tend to remain closed up more and more.
Poor ventilation results in a consistent buildup o moisture generated by cooking/bathing-showering/clotheswashing-drying/LPG gas heating/etc.
Why you need Ventilation?
Ventilation Selection
Trapping Moist Air Inside = Unhealthy Home
Problems Caused by Poor Ventilation
Stale air can be caused by cooking smells, odours remaining in the bathroom, a general lack o ventilationaround the house as well as a damp atmosphere.
All these problems cause an avoidable level o discomort as well as the risk o respiratory illness and generalpoor health.
Problems also occur when steam rom the kitchen or bathroom inds cooler suraces around the house on whichto condense. Warm, moisture-laden air condenses on cold suraces such as glass, cold ceilings and cold wet-wall linings. This is the moisture that you can see.
Moisture you cannot see is still present in the atmosphere and will be absorbed into abrics, wall linings,bedding, etc. Attempts to conserve heat by sealing windows - and thereore reducing natural ventilation - makesthis problem even worse.
Condensation can cause considerable problems rom peeling wallpaper and mould growth to severe long termstructural damage to building materials.
Moisture Generators:
KitchenToiletBathroom Showering Gas HeatingCondensation Laundry
Ventilate Outside = Healthy Home
In dwellings with a metal roo, or where the roo is lined with sarking, ventilatingdirectly into the roo space is not permitted under the Building Code.
-
7/23/2019 Fan Ventillation Calculations-HVAC
6/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au4
Ventilation Selection
Fan Placement
Careul location o an extraction an will ensuremaximum air-low through the room. Air extracted roma bathroom, or example, can be replaced with dry airdrawn rom an adjacent bedroom or hallway, in turn,drawn rom an open window or door. This ensuresthat resh air is being drawn into the entire house at
regular periods. Switching the an on beore starting showering or
cooking sets up eective air-lows beore the associatedcondensation problems occur. Closing doors to adjacentliving areas assists in stopping the transer o moistureto those areas but ensure that suicient air can enterunder the door to replace extracted air.
Use a door vent i necessary.
For a an to remove air eectively, the same amount oair being extracted must be able to enter the room. e.g.
air in = air out.
An air-tight room will mean no air movement. I the room istightly sealed (e.g. a tight-itting door, with no gap at the bottom),
you may need to it a through-door grille (see duct accessories)to allow replacement air into the room.
MEDIUM CIRCULATION
BEST CIRCULATION
Your Ventilation Solutions
POOR CIRCULATION
It is best to remove moisture rom where it is generatedto outside the house beore it has a chance to spread to
other parts o the house. Use ducted ans, through-wallans or window ans at all times. Do NOT use ceilingans which discharge into the ceiling cavity - this onlymoves the problem. Moisture will permeate insulationand ceiling linings causing urther problems.
In particular with bathrooms think in terms o room-conditioning. Warm, moist air is immediately attractedto cold suraces, where it condenses into water droplets.Cold suraces include glass, mirrors, tiles, wet-walllinings, cold un-insulated ceiling linings, etc. You cannotremove all o this air at a rate ast enough to stop this
happening and i you could, you would be standing in awind tunnel. Use o a bathroom heater to warm the roomprior to use greatly assists in reducing condensation.
Freshair in
Dampair out
Airfowthroughoutthehou
se
-
7/23/2019 Fan Ventillation Calculations-HVAC
7/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au 5
Australian Building Code Paragraph 3.8.5.0 states:
Perormance requirement P2.4.5 is satisied or mechanicalventilation system i it is installed in accordance with AS1668.2. Mechanical ventilation or acceptable indoor airquality, except that any contaminated air rom a sanitarycompartment or bathroom must:
(a) Exhaust directly to outside the building by way o
ducts; or
(b) Exhaust into the roo space provided:
i. It is adequately ventilated by open eaves, and/or roovents; or
ii. The roo is clad in rooing tiles without sarking
or similar materials, which would prevent venting
through gaps between tiles.
As detailed above, in dwellings with a metal roo, orwhere the roo is lined with sarking, ventilating directlyin to the roo space is not permitted by building codesunless the roo space is adequately ventilated by openeaves or roo vents.
The Manrose range oers many ducted solutions toexhaust to the outside through wall, roo or eaves tocomply with the latest building code. Natural Ventilationor the above is acceptable as long as opening windowsin each room have an area o 5% or more o the loorarea o the room.
What the law states
Fan Regulations
Ventilation Selection
AS1668 (summarised):
...Buildings shall have a means o collectingor otherwise removing: cooking umes andodours; steam rom laundering, utensilwashing, bathing and showering; odours romsanitary and waste storage spaces; poisonousor fammable umes and gases...
Bathrooms
The regulations require a an capableo a minimum extraction capacity o
25 litres per second when installed
Toilets
The regulations require a an capableo a minimum extraction capacity o25 litres per second when installed
Kitchens
The regulations require a an capableo a minimum extraction capacity o50 litres per second when installed
Laundries
The regulations require a an capableo a minimum extraction capacity o20 litres per second when installed
BCA Compliance to AS/NZ 1530 Part 3
Requirements are:Internal Surace: Spread o lame not >0
Smoke Developed not >3External Surace: Spread o lame not >7
Smoke developed not >5AS/NZS 1530 Part 3
This is the Australian standard 1530, method orire tests on building materials components andstructures.
Simultaneous determination o ignitability, lamepropagation, heat release and smoke release
Duct Standards
-
7/23/2019 Fan Ventillation Calculations-HVAC
8/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au6
1. Litres/Second (l/s)
2. Cubic Metres/Hour (m/hr) (Note: 1m3 = 1000 Litres).
3. ACH (Air changes per hour).
The number o times the total room volume o air ischanged each hour.
Reer to the table below or the recommended AirChanges per hour based on the room type.
Application Description Air Changes Per Hour
Bathrooms 11 - 15
Kitchens - (private) 15 - 20
Laundries - (no drier) 6 - 10
Laundries - (with drier) 10 - 30
Toilets 6 - 10
Bedroom 2 - 5
Oices 6 - 10
Cas 10 - 12
Canteens 8 - 12
Garages 6 - 8
Kitchens - (commercial) 20 - 30
Restaurants 8 - 12
Factories 8 - 10
Stores & Warehouses 3 - 6
Libraries 3 - 5
Classroom 5 - 7
Calculating Fan Perormance
To convert rom one to other types omeasurement:
I you know Litres/Second (l/s):l/s x 3.6 = m/hr.
(e.g. 25 l/s x 3.6 = 90m/hr)
I you know Cubic Metres/Hour (m/hr):m/hr 3.6 = l/s(e.g. 200m/hr 3.6 = 55.55 l/s)
milk
1 litre
1m1m
1m
4. Working out the right an or the job
1. Calculate the room volume in metres (L x W x H)2. Multiply the room volume by the recommended air
changes per hour or that room. Always use thehigher limit.
3. The result is the total perormance required in cubicmetres per hour.
Select a an with a higher perormance than this igure.
For Example:
What is the best an or a bathroom that is 2.8m long
by 2.8m wide with a ceiling height o 2.4m?
1. Calculate the volume o the bathroom:2.8 x 2.8 x 2.4 = 18.8m3
2 11-15 air changes per hour are recommended or abathroom. Multiply the room volume by 15:18.8m3 x 15 = 282m/hr
3. The an to choose or this bathroom would be a anthat perorms at greater than 282m/hr. A an that hasa perormance level o 313m/hr or higher (eg. XP150, orSF150) would do this job
Ventilation Selection
400
350
300
250
200
150
100
50
0
110
100
90
80
70
60
50
40
30
20
10
240
220
200
180
160
140
120
100
80
60
40
20
m3/hr l/s cfm
Quick Cross-Reerence CalculationsKnown To Find Action
l/s m/hr l/s x 3.6 =m/hr
m/hr l/s m/hr 3.6 = l/s
cm m/hr cm x 1.69 =m/hr
cm l/s cm x 0.47 = l/s
m/hr to l/s to cm Comparison Chart
5. Converting measurements
-
7/23/2019 Fan Ventillation Calculations-HVAC
9/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au 7
Compare Centriugal Against Axial Fan Perormance:
1. SF100 (axial) vs an SF200 (centriugal) anThe starting point is the ree air perormance o23l/s or the axial and 31l/s or the centriugal. Asduct is added to each o these ans, this increasesthe pressure (Pa) and decreases volume o airmoved. From the below example you can see that at20Pa o pressure the 100mm axial an airlow hasstopped whereas the 100mm centriugal an is stillmoving 29l/s!
Simple acts:
1. Fan size (i.e diameter o impeller & outlet)
2. Duct and the way it is installed
Smaller duct = greater resistance to airlow.
More bends = greater resistance to airlow.
Longer duct runs = increasingly reduced airlow.
Wrinkled ducting causes turbulence and reducesairlow
Smoother, extended ducting allows smooth, increasedairlow
3. Fan type
SF100 & SF200 PERFORMANCE GRAPH
2. ID150 (axial) vs a MAN150 (centriugal) an
The starting point is the ree air perormance o89l/s or the axial and 115l/s or the centriugal. Asduct is added to each o these ans, this increasesthe pressure (Pa) and decreases the volume o airmoved. From the below example you can see that at120Pa o pressure the 150mm axial an airlow hasstopped whereas the 150mm centriugal an is stillmoving 102l/s!
ID150 & MAN150 PERFORMANCE GRAPH
Centriugal Flow:Pressure developing ans which achieve good lowagainst the resistance created in a ducted system.Particularly useul in venting areas like internal
bathrooms/laundries, multi-room extractionsystems, heat-transer systems, etc.
Mix Flow:Powerul in-duct mounted ans, designed orapplications that require high air lows, with lowrelative noise.
Axial Flow:Suitable or wall, window and roo applicationswhere they can extract directly to the outside.Short duct runs are an option but the length o ductshould be limited.e.g. 100mm dia : 2-3m length
125mm dia : 3-4m length150mm dia : 4-5m length
WRINKLED DUCT AIRFLOW
SMOOTH DUCT AIRFLOW
What Aects Perormance?
SF200
SF100
50
150
100
200
250
300
0 20 40 60 80 100 120 140
5
15
10
20
25
30
0 72 144 216 288 360 432 504
MAN150
ID150
Manrose ALUDUCT lexible ducting
retains its stretched-out shape (orsmooth airlow) ar better than mostcompetitive products. Many competitiveducts tend to shrink back on themselves,wrinkling the duct abric.
Ventilation Selection
-
7/23/2019 Fan Ventillation Calculations-HVAC
10/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au8
Location o your ventilation an will depend on
the physical constraints o your room. The visualrecognition guide (shown on the right) will helpyou decide the most suitable physical installationto meet your requirements.
Within the above mounting options there arevarious other eatures available, such as :
TIMER(maintain an run-on ater the room isvacated)
PULLCORD(Switch at an, instead o light switchcontrol)
AUTO-SHUTTER(electrically operated shuttersinside the an - closed when the an is not running tostop draughts).
PIRSENSOR(provide automatic motion-sensorcontrol o ans)
Fan Applications
Wet Areas & Recommended Fan Types
When considering where in the room to place anextractor an, you must consider the wet areas.
Zone 1: This is the zone directly within the shower
or bath up to 2.25 metres above the loor and150mm around the bath/shower cubicle. A SELVan or an ln-line an kit will be required in this zone.For example i a an is mounted directly over thebath or shower it must be a low voltage an (SELV).
Zone 2: This zone is 0.6 metres horizontally outsideo zone 1 and 2.25 metres above the loor.
Zone 3: The outer layer is zone 3, which is 2.4metres horizontally outside o zone 2 and 2.25
metres above the loor.
Zone 1: Requires a Low Voltage Fanor an In-Line an kit
Zone 2: Any an model can be usedZone 3: Any an model can be used
- Wall/Ceiling Mounted Fans -Window Fans
-Thru Wall Fan Kits -Thru Roo Fan Kits
- In-Line Fan Kits - Low Voltage Fans
Shower
Low Voltage
Locate your Ventilation Fan
Ventilation Selection
How To OrderSelect the model that exhausts the closest to your requirements. I the perormance requiredalls between two ans, it is recommended you select the one handling the most air.
-
7/23/2019 Fan Ventillation Calculations-HVAC
11/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au 9
Window Mounted Fan:Used in situations where an existing window an is beingreplaced, or where there is no available external wall space andno ceiling space access.
Page Reerence 17
Fan Application Examples
Ceiling Mounted Fan:
Designed or low-pitch roos or between loors, where thereis no ceiling access. This enables the an to be accessible orservice ater installation. Also available with heat lamps &lighting.
Page Reerence 12 - 14 & 18
Thru Roo KitUsed where there is limited access to the roo space, or wherethere is no soit available. Thru Roo Kits can be used withany extraction an, or use a Thru Roo Fan Kit with the anmounted within the cowl.
Page Reerence 26
Thru Wall Fan Kit:Used where the bathroom is on an external wall, or there is noceiling space or an in-line an.
Page Reerence 15 - 16
In-Line Mounted Fan Kit:
Most common bathroom installation, the an is mounted in theceiling space with the grille directly above the source o thesteam. Generally this type o installation is quieter as the anis not directly in the room.
Page Reerence 19 - 21
For technical advice phone Customer Services 1300 666 595We are only too happy to oer advice on a custom build solution.
Ventilation Selection
-
7/23/2019 Fan Ventillation Calculations-HVAC
12/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au10
Selection Chart
Selecting the Right Fan is as easy as... 1, 2, 3
Select your required application
Eg: Bathrooms(11 - 15 air changes per hour)
Calculate the volume o the roomin cubic metres (m3) by multiplyingthe length x width x height.
Eg: 2.3m x 2.2m x 2.4m = 12.14m3
(Select a room volume 11-15m3)
Follow the 12m3 row acrossand select one o the an kitsavailable based on your mountingrequirements (see top headingsand photos)
Eg: I you require a Thru Wall Kitthen you can choose any o the
XP150 or XPLP150 kitsW
L
H
Wall/Ceiling Fans Thru Wall Fan Kits
Pro Series CLASSIC Pro Series CLASSIC
1-5m3 XFLP125 XF125 XPLP125 XP125
6-10m3 XFLP125 XF125 XPLP125 XP125
11-15m3 XFLP150 XF150 XPLP150 XP150
1-10m3 XFLP150 XF150 XPLP150 XP150
11-15m3 XFLP150 XF150 XPLP150 XP150
16-20m3 XFLP150 XF150 XPLP150 XP150
21-30m3 XFS230 XPS230
1-5m3 XFLP150 XF150 XPLP150 XP150
6-10m3 XFLP150 XF150 XPLP150 XP150
11-20m3 XFS230 XPS230
Room Type Room Size(m3)
- Toilets- Laundries - No drier- Cellar- Oces
These rooms requirebetween 6 and 10 ACH(Air changes per hour)
- Bathrooms- Showers- Ensuites
- Kitchens- Laundries - With drier
These rooms requirebetween 15 and 20 ACH(Air changes per hour)
These rooms require
between 11 and 15 ACH(Air changes per hour)
(18) (18) (18) (18)
1 2 3
-
7/23/2019 Fan Ventillation Calculations-HVAC
13/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au 11
Selection Chart
Note: All selections are based on installed an perormance and maximum air change rates (fgures in bracketsshow actual air changes stated i less than maximum)
Heat/Fan/Light Units
In-Line Fan Kits Extract-A-Lite KitsWindow
FansThru RooFan Kits
Pro Series Pro Series CLASSIC Pro Series CLASSIC CLASSIC CLASSIC
Heat n Vent 2 SFLP125 SF125 ELLP125 EL100 WF150 HYPER
Heat n Vent 2 SFLP125 SF125 ELLP125 EL125 WF150 HYPER
Heat n Vent 4 SFLP150 SF150 ELLP150 EL150 WF150 HYPER
Heatn Vent 2 SFLP150 SF150 ELLP125 EL150 WF150 HYPER
Heat n Vent 4 SFLP150 SF150 ELLP150 EL150 WF150 HYPER
SFLP150 SF150 ELLP150 EL150 WF150 ULTRA
MFLP150 WF230 ULTRA
SFLP150 SF150 ELLP125 EL150 WF150 HYPER
SFLP150 SF150 ELLP150 EL150 WF150 HYPER
MFLP150 WF230 ULTRA
(18)
-
7/23/2019 Fan Ventillation Calculations-HVAC
14/92
Ball
Bearin
gMotor
Year Warranty
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au12
Wall/Ceiling Mounted Fans
PRO-SERIES XFLP Low Proile Models
Metric Size Model No. SwitchingMethod
Performance Order Code
125mm XFLP125SS Standard 36l/s, 130m/hr FAN0589
125mm XFLP125ST Timer 36l/s, 130m/hr FAN0590
150mm XFLP150SS Standard 87l/s, 313m/hr FAN0594
150mm XFLP150ST Timer 87l/s, 313m/hr FAN0595
SQUARE MODELS
Metric Size Model No. SwitchingMethod
Performance Order Code
125mm XFLP125CS Standard 36l/s, 130m/hr FAN0604
125mm XFLP125CT Timer 36l/s, 130m/hr FAN0605
150mm XFLP150CS Standard 87l/s, 313m
/hr FAN0609150mm XFLP150CT Timer 87l/s, 313m
/hr FAN0610
CIRCULAR MODELS
Metric Size Model No. SwitchingMethod
Performance Order Code
125mm XFLP125SLV SELV 12V 36l/s, 130m/hr FAN0591
125mm XFLP125CLV SELV 12V 36l/s, 130m/hr FAN0606
150mm XFLP150SLV SELV 12V 87l/s, 313m/hr FAN0596
150mm XFLP150CLV SELV 12V 87l/s, 313m/hr FAN0611
Metric Size Description - Square Order Code
125mm Satin Silver Fascia FAN2068
125mm Chrome Fascia FAN0755
150mm Satin Silver Fascia FAN2071
150mm Chrome Fascia FAN0598
ACCESSORIES
Low Voltage Models
Square Models
Circular Models
Accessories - Square & Circular Fascia
Metric Size Description - Circular Order Code
125mm Satin Silver Fascia FAN2069125mm Chrome Fascia FAN0757
150mm Satin Silver Fascia FAN2070
150mm Chrome Fascia FAN0613
Unique low proile design enables these ans to be installed unobtrusively into any wall or ceiling These axial ans have been upgraded with ball bearing motors to prolong the lie o the motor Supported by a ive year warranty For technical speciication reer page 51
Please Note: An isolating transormer is required or all low voltage ans. Low Voltage models do
not include a transormer. (We recommend a SELV isolating transormer Order Code: FAN2402)
Switching Options:1. Standard Model - operates rom remote switch (not supplied).
2. Timer Model - Fan operates rom a switch, the an continues to run or a preset time
ater switching o - adjustable 1-20 minutes.
Requires three wires: permanent phase, switched phase, neutral.
3. SELV Model - Suitable or installation in damp areas, zones 1, 2 and 3.
NOTE: All an low rates quoted are ree air delivery.
SAFETY EXTRA LOW VOLTAGE (SELV) MODELS
-
7/23/2019 Fan Ventillation Calculations-HVAC
15/92
Ball
Bearin
gMotor
Year Warranty
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au 13
Wall/Ceiling Mounted Fans
CLASSIC XF Models
Commercial Models
Auto Shutter Models
Low Voltage Models
Standard Models
COMMERCIAL MODELS
Metric Size Model No. SwitchingMethod
Performance Order Code
150mm XF150PIR PIR Control 87l/s, 313m/hr FAN0124
230mm XFS230S Standard 152l/s, 550m/hr FAN0374
300mm XFS300S Standard 306l/s, 1100m/hr FAN2040
AUTO SHUTTER MODELS
Metric Size Model No. SwitchingMethod
Performance Order Code
150mm XF150A Standard 87l/s, 313m
/hr FAN0121150mm XF150AP Pull Cord 87l/s, 313m
/hr FAN0122
150mm XF150AT Timer 87l/s, 313m/hr FAN0123
230mm XFS230A Standard 152l/s, 550m/hr FAN0346
300mm XFS300A Standard 306l/s, 1100m/hr FAN2041
Metric Size Model No. SwitchingMethod
Performance Order Code
100mm XF100LV SELV 12V 23l/s, 85m/hr FAN0044
125mm XF125LV SELV 12V 36l/s, 130m/hr FAN0071
150mm XF150LV SELV 12V 87l/s, 313m/hr FAN0119
Metric Size Model No. SwitchingMethod
Performance Order Code
100mm XF100S Standard 23l/s, 85m/hr FAN0046
100mm XF100P Pull Cord 23l/s, 85m/hr FAN0047
100mm XF100T Timer 23l/s, 85m/hr FAN0048
125mm XF125S Standard 36l/s, 130m/hr FAN0072
125mm XF125P Pull Cord 36l/s, 130m/hr FAN0074
125mm XF125T Timer 36l/s, 130m/hr FAN0075
150mm XF150S Standard 87l/s, 313m/hr FAN0120
150mm XF150P Pull Cord 87l/s, 313m/hr FAN0126
150mm XF150T Timer 87l/s, 313m/hr FAN0127
STANDARD MODELS
Designed or wall or ceiling mounting, these models are eicient and easy to install These axial ans have been upgraded with ball bearing motors to prolong the lie o the motor Supported by a ive year warranty For technical speciication reer page 52 & 57
Switching Options:1. Standard Model - operates rom remote switch (not supplied).
2. Timer Model - Fan operates rom a switch, the an continues to run or a preset time
ater switching o - adjustable 1-20 minutes.
3. Pull Cord Model - Integral pullcord switch on an.
4. Auto Shutters - Electrically operated louvre shutters open automatically when an is
running - prevents back-draughts.5. PIR Model - Motion sensor incorporated in an.
6. SELV Model - Suitable or installation in damp areas, zones 1, 2 and 3.
NOTE: All an low rates quoted are ree air delivery.
Please Note: An isolating transormer is required or all low voltage ans. Low Voltage models donot include a transormer. (We recommend a SELV isolating transormer Order Code: FAN2402)
SAFETY EXTRA LOW VOLTAGE (SELV) MODELS
-
7/23/2019 Fan Ventillation Calculations-HVAC
16/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au14
Wall/Ceiling Mounted Fans
Switching Options:1. Standard Model - operates rom remote switch (not supplied).
2. Timer Model - Fan operates rom a switch, the an continues to run or a preset time ater switching o - adjustable 1-20 minutes.
Requires three wires: permanent phase, switched phase, neutral.
3. PIR Model - Motion sensor incorporated in an. Range up to 5 metres.
CLASSIC CF Multi-Vent Models
CLASSIC CF Models
DESIGNER Ceiling Fan Models
Designed or apartments where space is limited, these ceiling mounted anscan be installed in conined spaces
The centriugal an design is whisper quiet in operation Supported by a two year warranty For technical speciication reer page 53
Metric Size Model No. SwitchingMethod
Performance Order Code
100mm WVC100W Standard 63l/s, 225m
/hr FAN0884100mm WVC100S Standard 63l/s, 225m
/hr FAN0885
FLUSH FITTING RANGE
Metric Size Model No. SwitchingMethod
Performance @Speed 3
Order Code
100mm FFCF234S Standard 65l/s, 234m/hr FAN0038
100mm FFCF234T Timer 65l/s, 234m/hr FAN0499
100mm FFCF234PIR PIR 65l/s, 234m/hr FAN0501
SURFACE MOUNT RANGE
Metric Size Model No. SwitchingMethod
Performance @Speed 3
Order Code
100mm SMCF234S Standard 65l/s, 234m/hr FAN0504
100mm SMCF234T Timer 65l/s, 234m/hr FAN0505
Designed or apartments where space is limited, with a choice o wall orceiling mounted system
These Models include centriugal ans with a choice o three in-built speedsettings depending on the perormance required
Supported by a two year warranty For technical speciication reer page 53
Metric Size Model No. SwitchingMethod
Performance @Speed 1
Order Code
100mm CF200S Standard 31l/s, 110m/hr FAN0041
100mm CF200TP Timer 31l/s, 110m/hr FAN0042
Designed to move air over long distances The centriugal an design provides eicient airlow and quiet operation Supported by a two year warranty For technical speciication reer page 53
NOTE: All an low rates quoted are ree air delivery.
Year Warranty
Year Warranty
Year Warranty
-
7/23/2019 Fan Ventillation Calculations-HVAC
17/92
Ball
Bearin
gMotor
Year Warranty
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au 15
Thru Wall Fan Kits
PRO-SERIES XPLP Low Proile Models
Switching Options:1. Standard Model - operates rom remote switch (not supplied).
2. Timer Model - Fan operates rom a switch, the an continues to run or a preset time
ater switching o - adjustable 1-20 minutes. Requires three wires: permanent phase,
switched phase, neutral.
Metric Size Model No. Switching
Method
Performance Order Code
125mm XPLP125SS Standard 36l/s, 130m/hr FAN0614
125mm XPLP125ST Timer 36l/s, 130m/hr FAN0615
150mm XPLP150SS Standard 87l/s, 313m/hr FAN0621
150mm XPLP150ST Timer 87l/s, 313m/hr FAN0623
STANDARD MODELS
Standard Models
Accessories - Square & Circular Fascia
Low Voltage Models
Metric Size Model No. SwitchingMethod
Performance Order Code
125mm XPLP125SLV SELV 12V 36l/s, 130m/hr FAN0620
125mm XPLP125CLV SELV 12V 36l/s, 130m
/hr FAN0735150mm XPLP150SLV SELV 12V 87l/s, 313m
/hr FAN0732
150mm XPLP150CLV SELV 12V 87l/s, 313m/hr FAN0738
The unique Low Proile design enables these ans to be installed unobtrusively into any wall
(requires a minimum wall cavity o 110mm) These axial ans have been upgraded with ball bearing motors to prolong the lie o the motor Supported by a ive year warranty For technical speciication reer page 54
Metric Size Description - Square Order Code
125mm Satin Silver Fascia FAN2068
125mm Chrome Fascia FAN0755
150mm Satin Silver Fascia FAN2071
150mm Chrome Fascia FAN0598
ACCESSORIES
Metric Size Description - Circular Order Code
125mm Satin Silver Fascia FAN2069
125mm Chrome Fascia FAN0757
150mm Satin Silver Fascia FAN2070
150mm Chrome Fascia FAN0613
3. SELV Models - Suitable or installation in damp areas, zones 1, 2 and 3.
NOTE: All an low rates quoted are ree air delivery.
Please Note: An isolating transormer is required or all low voltage ans. Low Voltage models donot include a transormer. (We recommend a SELV isolating transormer Order Code: FAN2402)
SAFETY EXTRA LOW VOLTAGE (SELV) MODELS
-
7/23/2019 Fan Ventillation Calculations-HVAC
18/92
Ball
Bearin
gMotor
Year Warranty
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au16
Thru Wall Mounted Fan Kits
Switching Options:1. Standard Model - operates rom remote switch (not supplied).
2. Timer Model - Fan operates rom a switch, the an continues to run or a preset
time ater switching o - adjustable 1-20 minutes. Requires three wires: permanent
phase, switched phase, neutral.
3. Pull Cord Model - Integral pullcord switch on an.
4. Auto Shutters - Electrically operated louvre shutters open automatically when an isrunning - prevents back-draughts.
5. SELV Models - Suitable or installation in damp areas, zones 1, 2 and 3.
NOTE: All an low rates quoted are ree air delivery.
CLASSIC XP Models
Auto Shutter Models
Standard Models
Low Voltage Models
Metric Size Model No. SwitchingMethod
Performance Order Code
100mm XP100S Standard 23l/s, 85m/hr FAN0053
100mm XP100P Pull Cord 23l/s, 85m/hr FAN0054
100mm XP100T Timer 23l/s, 85m/hr FAN0055
125mm XP125S Standard 36l/s, 130m/hr FAN0080
125mm XP125P Pull Cord 36l/s, 130m/hr FAN0082
125mm XP125T Timer 36l/s, 130m/hr FAN0083
150mm XP150S Standard 87l/s, 313m/hr FAN0135
150mm XP150P Pull Cord 87l/s, 313m/hr FAN0140
150mm XP150T Timer 87l/s, 313m/hr FAN0141
STANDARD MODELS
AUTO SHUTTER MODELS
Metric Size Model No. SwitchingMethod
Performance Order Code
150mm XP150A Standard 87l/s, 313m/hr FAN0136
150mm XP150AP Pull Cord 87l/s, 313m
/hr FAN0137150mm XP150AT Timer 87l/s, 313m/hr FAN0138
230mm XPS230A Standard 152l/s, 550m/hr FAN0348
300mm XPS300A Standard 306l/s, 1100m/hr FAN2043
These ans are designed to be ducted straight through an exterior wall and are eicient and easy to install These axial ans have been upgraded with ball bearing motors to prolong the lie o the motor Supported by a ive year warranty For technical speciication reer page 55 & 57
Metric Size Model No. SwitchingMethod
Performance Order Code
100mm XP100LV SELV 12V 25l/s, 85m/hr FAN0409
125mm XP125LV SELV 12V 36l/s, 130m/hr FAN0410
150mm XP150LV SELV 12V 87l/s, 313m
/hr FAN0411
Commercial Models
COMMERCIAL MODELS
Metric Size Model No. SwitchingMethod
Performance Order Code
230mm XPS230S Standard 152l/s, 550m/hr FAN0455
300mm XPS300S Standard 306l/s, 1100m/hr FAN2042
Please Note: An isolating transormer is required or all low voltage ans. Low Voltage models donot include a transormer. (We recommend a SELV isolating transormer Order Code: FAN2402)
SAFETY EXTRA LOW VOLTAGE (SELV) MODELS
-
7/23/2019 Fan Ventillation Calculations-HVAC
19/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au 17
Standard Models
Standard Larger Models
CLASSIC WF Models
CLASSIC COM Models
Window Mounted Fans
Commercial Auto Shutter Models
Metric Size Model No. SwitchingMethod
Performance Order Code
100mm WF100P Pull Cord 23l/s, 85m/hr FAN0021
100mm WF100PLV Low Voltage 23l/s, 85m/hr FAN0452
STANDARD MODELS
Metric Size Model No. SwitchingMethod
Performance Order Code
150mm WF150MP Pull Cord 87l/s, 313m/hr FAN0110
150mm WF150MPLV SELV 12 87l/s, 313m/hr FAN0355
Auto Shutter Models
AUTO SHUTTER MODELS
Metric Size Model No. SwitchingMethod
Performance Order Code
150mm WF150AP Pull Cord 87l/s, 313m/hr FAN0107
150mm WF150APT Pull Cord Timer 87l/s, 313m/hr FAN0109
230mm WF230AP Pull Cord 152l/s, 550m/hr FAN0146
300mm WF300A Standard 306l/s, 1100m/hr FAN0482
COMMERCIAL AUTO SHUTTER MODELS
Metric Size Model No. Switching
Method
Performance Order Code
230mm COM230A Standard 185l/s, 670m/hr FAN0519
230mm COM230MP Standard 185l/s, 670m/hr FAN0518
300mm COM300A Standard 280l/s,1020m/hr FAN0521
300mm COM300MP Standard 280l/s,1020m/hr FAN0520
Designed or use in situations where an existing window an is being replaced orwhere there is no available external wall space or ceiling space access
These axial ans have been upgraded with ball bearing motors to prolong the lieo the motor and are supported by a ive year warranty
For technical speciication reer page 56 & 58
MANUAL SHUTTER MODELS
Metric Size Model No. SwitchingMethod
Performance Order Code
230mm WF230P Pull Cord 152l/s, 550m/hr FAN0148
300mm WF300P Pull Cord 306l/s, 1100m/hr FAN0481
STANDARD LARGER MODELS
Switching Options:1. Standard Model - operates rom remote switch (not supplied).
2. Timer Model - Fan operates rom a switch, the an continues to run or a preset time
ater switching o - adjustable 1-20 minutes.
3. Pull Cord Model - Integral pullcord switch on an.
4. Auto Shutters - Electrically operated louvre shutters open automatically when an is
running - prevents back-draughts.5. Manual Pullcord - Pullcord operates an and manual shutters.
6. SELV Models - Suitable or installation in damp areas, zones 1, 2 and 3.
NOTE: All an low rates quoted are ree air delivery.
Designed or commercial applications such as pubs, restaurants, hotels, shops etc These axial ans include ball bearing motors to prolong the lie o the motor Supported by a ive year warranty For technical speciication reer page 58
Ball
Bearin
gMotor
Year Warranty
Please Note: An isolating transormer is required or all low voltage ans. Low Voltage models donot include a transormer. (We recommend a SELV isolating transormer Order Code: FAN2402)
-
7/23/2019 Fan Ventillation Calculations-HVAC
20/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au18
Ball
Bearin
gMotor
Year Warranty
PRO-SERIES Heat n Vent Models
CLASSIC 2 Heat n Light
CLASSIC Heat n Vent 2
Heat/Fan/Light Kits
Metric Size Model No. Performance Order Code
125mm Heat n Vent 4 60l/s, 216m/hr FAN0995
125mm Heat n Vent 2 50l/s, 180m/hr FAN0940
ACCESSORIES
Metric Size Description Order Code
125mm Heat n Vent 4 Silver Fascia FAN1015
125mm Heat n Vent 2 Silver Fascia FAN1014
275W Heat Lamp LHT0081
50W Halogen GU10 lamp LHT0140
With a 40% increase in perormance* these systems meet the demands olarger bathrooms and the stylish ascia blends into the decor
These high eiciency centriugal ans incorporate a unique anti- condensatedesign eature
Supported by a ive year warranty For technical speciication reer page 59
Metric Size Model No. Performance Order Code
100mm Heat n Vent 2 35l/s, 126m/hr FAN2162
Metric Size Description Order Code
100mm 2 Heat n Light (excludes fan) FAN2200
This system delivers instant heat combined with ventilation and sot lighting tocreate a comort area in small bathrooms
Supported by a ive year warranty For technical speciication reer page 59
This system provides instant heat and additional lighting For a complete bathroom solution an extraction an can be added Supported by a ive year warranty For technical speciication reer page 59
Switching Options:1. Standard Model - operates rom remote switch (not supplied).
NOTE: All an low rates quoted with 3 metres o duct, one bend and one external grille (normal installation).
* Increase in perormance is based on the comparison to the previous models.
Pro-Series Heat n Vent 4
Pro-Series Heat n Vent 2
NEW
Classic Heat n Vent 2
2 Heat n Light
-
7/23/2019 Fan Ventillation Calculations-HVAC
21/92
Ball
Bearin
gMotor
Year Warranty
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au 19
CLASSIC SF Shower Fan Models
In-Line Mounted Fan Kits
PRO-SERIES SFLP Shower Fan Models
PRO-SERIES MIXFLO Shower Fan Models
Metric Size Model No. SwitchingMethod
Performance Order Code
100mm MFLP100S Standard 69l/s, 250m/hr FAN2049
125mm MFLP125S Standard 89l/s, 320m/hr FAN2050
150mm MFLP150S Standard 156l/s, 560m/hr FAN2051
These powerul inline mixed low ans have been designed to produce higher workingpressures or applications that require higher airlows with low relative noise levels
Supported by a ive year warranty For technical speciication reer page 60
Metric Size Model No. SwitchingMethod
FanType
Performance Order Code
125mm SFLP125S Standard Ctrgl 39l/s, 140m/hr FAN0616
125mm SFLP125T Timer Ctrgl 39l/s, 140m/hr FAN0617
150mm SFLP150S Standard Whisp 94l/s, 340m/hr FAN0618
150mm SFLP150T Timer Whisp 94l/s, 340m/hr FAN0619
Metric Size Model No. SwitchingMethod
FanType
Performance Order Code
100mm SF100S Standard Axial 23l/s, 85m/hr FAN0017
100mm SF100T Timer Axial 23l/s, 85m/hr FAN0018
100mm SF200S Standard Ctrgl 31l/s, 110m/hr FAN0328
100mm SF200T Timer Ctrgl 31l/s, 110m/hr FAN0329
125mm SF125S Standard Axial 36l/s, 130m/hr FAN0064
125mm SF125T Timer Axial 36l/s, 130m/hr FAN0065
150mm SF150S Standard Axial 87l/s, 313m/hr FAN0101
150mm SF150T Timer Axial 87l/s, 313m/hr FAN0102
Switching Options:1. Standard Model - operates rom remote switch (not supplied).
2. Timer Model - Fan operates rom a switch, the an continues to run or a preset time ater switching o. The 100 and 125mm models are adjustable between 1-20 minutes,
whereas the 150mm models include a ixed 7 minute timer. Both require three wires: permanent phase, switched phase, neutral.NOTE: All an low rates quoted are ree air delivery. Perormance will be aected by the length o ducting used.
These high eiciency inline ans are designed to provide higher levels oextraction or todays larger bathrooms
Supported by a ive year warranty
For technical speciication reer page 61
With the an mounted in the ceiling space, these in-line models are able to draw steam directly rom source These ans have been upgraded with ball bearing motors to prolong the lie o the motor Supported by a ive year warranty For technical speciication reer page 62
SFLP150
MKLP150
SF150
i
i i i
i i 'i l i i li i
l i
i i i i
li l li i l
li i i' i li
l i il i
l i l i l i ii l i i
il i
lli i l i li i iil i i l i i i il i
l i l il. . .
l i i
-
7/23/2019 Fan Ventillation Calculations-HVAC
22/92
Ball
Bearin
gMotor
Year Warranty
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au20
In-Line Mounted Fan Kits
PRO-SERIES ELLP Extract-a-lite Low Proile Models
Metric Size Model No. SwitchingMethod
Performance Order Code
125mm ELLP125WS - Wht Standard 39l/s, 140m
/hr FAN2029125mm ELLP125WT - Wht Timer 39l/s, 140m
/hr FAN2031
125mm ELLP125SS - Slv Standard 39l/s, 140m/hr FAN2030
125mm ELLP125ST - Slv Timer 39l/s, 140m/hr FAN2032
150mm ELLP150WS - Wht Standard 94l/s, 340m/hr FAN2033
150mm ELLP150WT - Wht Timer* 94l/s, 340m/hr FAN2035
150mm ELLP150SS - Slv Standard 94l/s, 340m/hr FAN2034
150mm ELLP150ST - Slv Timer* 94l/s, 340m/hr FAN2036
These high eiciency inline ans are designed to provide higher levels o extractionor larger bathrooms and include a stylish downlight
White or satin silver inish available to complement your bathroom decor Electronic Transormer included in the kit to operate the 12V downlight Supported by a ive year warranty For technical speciication reer page 63
* Includes a 7 minute xed timer
Metric Size Description Order Code
125mm Pro Series ELLP Diuser White incl lamp DCT1519
125mm Pro Series ELLP Diuser Silver incl lamp DCT1520
150mm Pro Series ELLP Diuser White incl lamp DCT1521
150mm Pro Series ELLP Diuser Silver incl lamp DCT1522
12V 35-50W dichroic lamp with 60 angle beam FAN0431
Electronic Transormer 12VAC 50kHz FAN2101
ACCESSORIES
NOTE: All an low rates quoted are ree air delivery. Perormance will be aected by the length o ducting used.
Switching Options:1. Standard Model - operates rom remote switch (not supplied).
2. Timer Model - Fan operates rom a switch, the an continues to run or a preset time ater switching o. The 100 and 125mm models are adjustable between 1-20 minutes,
whereas the 150mm models include a ixed 7 minute timer. Both require three wires: permanent phase, switched phase, neutral.
ELLP150SS
ELLP125SW
125mm ELLP Diusers
-
7/23/2019 Fan Ventillation Calculations-HVAC
23/92
Ball
Bearin
gMotor
Year Warranty
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au 21
CLASSIC EL Extract-a-lite Models
In-Line Mounted Fan Kits
Metric Size Description Order Code
100mm EL Diuser white incl lamp DCT0360
100mm EL Diuser chrome incl lamp DCT0362
125mm EL Diuser white incl lamp DCT2121
125mm EL Diuser chrome incl lamp DCT2120
150mm EL Diuser white incl lamp DCT1169
150mm EL Diuser chrome incl lamp DCT1171
100mm Accessory chrome bezel - Extract-a-lite DCT0366
125mm Accessory chrome bezel - Extract-a-lite FAN2076
150mm Accessory chrome bezel - Extract-a-lite FAN0827
12V 35-50W dichroic lamp with 60 angle beam FAN0431
Electronic Transormer 12VAC 50kHz FAN2101
ACCESSORIES
Metric Size Model No. SwitchingMethod
Performance Order Code
100mm EL100S Standard 31l/s, 110m
/hr FAN0420100mm EL100T Timer 31l/s, 110m
/hr FAN0438
125mm EL125S Standard 36l/s, 130m/hr FAN2037
125mm EL125T Timer 36l/s, 130m/hr FAN2038
150mm EL150S Standard 87l/s, 313m/hr FAN0803
150mm EL150T Timer 87l/s, 313m/hr FAN0804
The an is mounted in the ceiling space, and is thereore able to draw steam directly romsource, while at the same time providing spot lighting within your bathroom
These ans have been upgraded with ball bearing motors to prolong the lie o the motor
Electronic Transormer included in the kit to operate the 12V downlight Supported by a ive year warranty For technical speciication reer page 64
NOTE: All an low rates quoted are ree air delivery. Perormance will be aected by the length o ducting used.
Switching Options:1. Standard Model - operates rom remote switch (not supplied).
2. Timer Model - Fan operates rom a switch, the an continues to run or a preset time ater switching o. Adjustable between 1-20 minutes. Requires three wires: permanent
phase, switched phase, neutral.
125mm EL Diusers
EL150S
-
7/23/2019 Fan Ventillation Calculations-HVAC
24/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au22
In-Line Duct Mounted Fans
PRO-SERIES WhisperVent Models
CLASSIC Hyper150 Models
Metric Size Model No. Switching
Method
Performance Order Code
150mm WVI150 Standard 94l/s, 340m/hr FAN0916
This high eiciency inline an is designed to provide higher levels o extractionwith low relative noise
The ball bearing motor prolongs the lie o the motor Supported by a ive year warranty For technical speciication reer page 65
Metric Size Model No. Switching
Method
Performance Order Code
150mm Hyper150 Standard 89l/s, 320m/hr FAN0085
Switching Options:1. Standard Model - operates rom remote switch (not supplied).
NOTE: All an low rates quoted are ree air delivery.
This high eiciency inline an is designed to provide high levels o extraction The ball bearing motor prolongs the lie o the motor Supported by a ive year warranty Includes 1.3m lead and 3 pin plug For technical speciication reer page 65
PRO-SERIES MIXFLO Fan ModelsMetric Size Model No. Switching Method Performance @
High SpeedOrder Code
100mm MF100S Standard 2 Speed 69l/s, 250m
/hr FAN1004100mm MF100T Timer 2 Speed 69l/s, 250m
/hr FAN2124
100mm MF100PL Plug & Lead 2 Speed 69l/s, 250m/hr FAN1050
125mm MF125S Standard 2 Speed 89l/s, 320m/hr FAN1005
125mm MF125T Timer 2 Speed 89l/s, 320m/hr FAN2125
125mm MF125PL Plug & Lead 2 Speed 89l/s, 320m/hr FAN1051
150mm MF150S Standard 2 Speed 156l/s, 560m/hr FAN1006
150mm MF150T Timer 2 Speed 156l/s, 560m/hr FAN2126
150mm MF150PL Plug & Lead 2 Speed 156l/s, 560m/hr FAN1048
200mm MF200S Standard 3 Speed 253l/s, 910m/hr FAN1007
200mm MF200T Timer 2 Speed 253l/s, 910m/hr FAN2127
200mm MF200PL Plug & Lead 3 Speed 253l/s, 910m/hr FAN1053
These powerul inline mixed low ans have been designed to produce higher workingpressures or applications that require higher airlows with low relative noise levels
Supported by a our year warranty or 30,000 continuous hours For technical speciication reer page 60
30
,000
HOURS
Year Warranty4
Ball
Bearin
gMotor
Year Warranty
-
7/23/2019 Fan Ventillation Calculations-HVAC
25/92
Ball
Bearin
gMotor
Year Warranty
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au 23
In-Line Mounted Fans
CLASSIC CFD Models
Metric Size Model No. Switch Method Performance Order Code
100mm CFD200S Standard 31l/s, 110m
/hr FAN0326100mm CFD200T Timer 31l/s, 110m/hr FAN0327
125mm CFD225S Standard 39l/s, 140m/hr FAN2067
125mm CFD225T Timer 39l/s, 140m/hr FAN2066
CLASSIC ID Models
Metric Size Model No. SwitchingMethod
Performance Order Code
100mm ID100S Standard 23l/s, 85m/hr FAN0012
100mm ID100T Timer 23l/s, 85m/hr FAN0013
125mm ID125S Standard 36l/s, 130m/hr FAN0060
125mm ID125T Timer 36l/s, 130m/hr FAN0061
150mm ID150S Standard 87l/s, 313m/hr FAN0090
150mm ECO150S Standard 64l/s, 230m/hr FAN2078
150mm ID150T Timer 87l/s, 313m/hr FAN0091
230mm ID230S Standard 152l/s, 550m/hr FAN0405
230mm ID230T Timer 152l/s, 550m/hr FAN0406
With the an mounted in the ceiling space, these in-line models are able to draw steamdirectly rom source
These axial ans have been upgraded with ball bearing motors to prolong the lie o the motor Supported by a ive year warranty For technical speciication reer page 66
These high eiciency centriugal ans are designed or use where longer ductruns are required.
The ball bearing motor prolongs the lie o the motor Supported by a ive year warranty For technical speciication reer page 67
Switching Options:1. Standard Model - operates rom remote switch (not supplied).
2. Timer Model - Fan operates rom a switch, the an continues to run or a preset time ater switching o - adjustable 1-20 minutes.
Requires three wires: permanent phase, switched phase, neutral.
NOTE: All an low rates quoted are ree air delivery.
-
7/23/2019 Fan Ventillation Calculations-HVAC
26/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au24
High Perormance Centriugal 3 Speed Models
In-Line Mounted Fans
High Perormance Centriugal Models
WhisperVent Low Proile Centriugal Models
Metric Size Model No. Performance @ Speed 3 Order Code
150mm 3 Speed 115l/s, 415m/hr FAN0921
200mm 3 Speed 208l/s, 750m/hr FAN0997
Metric Size Model No Performance Order Code
100mm MAN100 49l/s, 176m/hr FAN0361
125mm MAN125 61l/s, 220m/hr FAN0360
150mm MAN150 115l/s, 415m/hr FAN0330
200mm MAN200 208l/s, 750m/hr FAN0467
250mm MAN250 280l/s, 1010m/hr FAN0358
315mm MAN315 360l/s, 1300m/hr FAN0357
Suitable or a variety o domestic and commercial applications, these inlinecentriugal ans provide extremely high perormance with a choice o sizes
Supported by a two year warranty For technical speciication reer page 68
Switching Options:1. Standard Model - operates rom remote switch (not supplied).
NOTE: All an low rates quoted are ree air delivery.
Metric Size Model No Performance Order Code
150mm WVILP150-1 124l/s, 445m/hr FAN0829
150mm WVILP150-3 118l/s, 425m/hr FAN0830
Suitable or a variety o domestic and commercial applications, these inlinecentriugal ans provide high perormance at your pre-set choice o speed
Supported by a two year warranty For technical speciication reer page 69
Suitable or a variety o domestic and commercial applications, this inline
centriugal an oers high perormance with a low proile design to enablethis unit to be installed in conined spaces
Supported by a two year warranty For technical speciication reer page 70
Year Warranty
Please note: Can be used or supply/extract
Please note: Can be used or supply/extract
-
7/23/2019 Fan Ventillation Calculations-HVAC
27/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au 25
Year Warranty
Externally Mounted Fans - Extract
Wall Mounted Fans
Externally Mounted Fans - 3 Speed Extract
Metric Size Fan Type Air Performance Order Code
150mm Axial Extract 73l/s, 263m3hr FAN2303
150mm Ctrgl (190 Motor) Extract 109l/s, 392m3hr FAN2301
150mm Ctrgl (220 Motor) Extract 133l/s, 480m/hr FAN2302
Metric Size Fan Type Air Performance
(High Speed)
Order Code
150mm Ctrgl (190 Motor) Extract 113l/s, 408m3hr FAN2316
150mm Ctrgl (220 Motor) Extract 136l/s, 493m/hr FAN2317
Designed or use in residential and light commercial applications where ahigh perormance, low noise solution is required
Speciic applications include apartments where space is limited
Supported by a two year warranty
For technical speciication reer page 71
NOTE: All an low rates quoted are ree air delivery.
Connection:1. Electrical connection must be made internally (Junction Box is only suitable or internal use).
Designed or use in residential and light commercial applications where ahigh perormance, low noise solution is required
Three speed models enable urther lexibility in a variety o applications
Speciic applications include apartments where space is limited Supported by a two year warranty
For technical speciication reer page 71
NEW
NEW
-
7/23/2019 Fan Ventillation Calculations-HVAC
28/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au26
Thru Roo Fan Cowl Models
Thru Roo Fan System Models
Thru Roo Mounted Fans
Thru Roo Fan Models with Dektite & HDPE Tube
Metric Size Fan Type Air Performance* Order Code
150mm Ctrgl Extract 130l/s, 468m/hr FAN0529
150mm Ctrgl 3-spd Extract 130l/s, 468m
/hr FAN1002150mm Axial - Whisper Extract 89l/s, 320m/hr FAN1009
150mm Axial Extract 80l/s, 288m/hr FAN0531
150mm Axial Supply 80l/s, 288m/hr FAN0533
Metric Size Fan Type Air Performance* Order Code
150mm Ctrgl Extract 130l/s, 468m/hr FAN0530
150mm Ctrgl 3-spd Extract 130l/s, 468m/hr FAN0967
150mm Axial - Whisper Extract 89l/s, 320m/hr FAN1060
150mm Axial Extract 80l/s, 288m/hr FAN0532
150mm Axial Supply 80l/s, 288m/hr FAN0534
Metric Size Description Fan Type Performance* Order Code
150mm Ultra Ctrgl 130l/s, 468m/hr FAN0535
150mm Hyper Hyper 89l/s, 320m/hr DCT0189
High quality aluminium cowl construction, with an incorporated, orlongevity o operation
Supported by a two year warranty For technical speciication reer page 72
High quality aluminium cowl construction, with an incorporated, or longevityo operation
Includes Dektite or metal based roos, an optional lead dektite is available orconcrete tile roos (DCT0190) at an additional cost Supported by a two year warranty For technical speciication reer page 72
* NOTE: All an low rates quoted are motor perormance in ree air.
Connection:1. Electrical connection can be made inside or outside the roo space.
High quality aluminium cowl construction, with an incorporated, orlongevity o operation
Includes Dektite or metal based roos, an optional lead dektite isavailable or concrete tile roos (DCT0190) at an additional cost
Supported by a two year warranty For technical speciication reer page 72
Year Warranty
-
7/23/2019 Fan Ventillation Calculations-HVAC
29/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au 27
A compact extractor an combinedwith an integral halogen light
Designed or installation in galleys,showers and toilets, ideal or marineand other leisure applications
Long lie computer motor which willrun continuously, only 2.8 watts
Supported by a two year warranty For technical speciication reer
page 73
External cowl suitable or use in marine and non-marine applications
CLASSIC DC Extract-a-lite Models
Specialised Ceiling Mounted Fans
12/24 volts, DC suitable or marine/recreational vehicle use.
Metric Size Model No. Switching
Method
Colour Performance Order Code
100mm BSL112W Standard White 18l/s, 64m/hr FAN0625
100mm BSL112G Standard Gold 18l/s, 64m/hr FAN0690
100mm BSL112C Standard Chrome 18l/s, 64m/hr FAN0691
100mm BSL124W Standard White 18l/s, 64m/hr FAN0626
100mm BSL124G Standard Gold 18l/s, 64m/hr FAN0686
100mm BSL124C Standard Chrome 18l/s, 64m/hr FAN0685
Metric Size Description Order Code
100mm Extract-a-lite cowl DCT1097
ACCESSORIES - EXTRACT-A-LITE COWL
Switching Options:1. Standard Model - operates rom remote switch (not supplied)
NOTE: All an low rates quoted are ree air delivery.
Year Warranty
-
7/23/2019 Fan Ventillation Calculations-HVAC
30/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au28
Specialised Fans
Product codes1. Product with the order code showing are generally ex-stock - other products are available to orderNOTE: All an low rates quoted are ree air delivery.
CLASSIC Hand Dryer Models
High quality, warm air hand drier that is suitable or use within oice andcommercial organisations, such as clinics and catering establishments
It is not recommended or use in public areas prone to vandalism Supported by a two year warranty For technical speciication reer page 67
Metric Size(mm)
Model No. SwitchingMethod
Performance Order Code
275x225x160 MAN M-88A Auto 56l/s, 200m
/hr FAN2902
This model is suitable or use in public areas such as lavatories, actories,schools, railways and motorway service stations and are designed or heavyusage and unsupervised areas
Supported by a two year warranty For technical speciication reer page 67
Metric Size(mm)
Model No. SwitchingMethod
Performance Order Code
248x284x202 MAN/E-88A Auto 130l/s, 470 m/hr FAN2903
Frame Fan Model
Metric Size Model No. SwitchingMethod
Performance Order Code
125mm Frame Fan Standard 38l/s, 138m
/hr FAN0397150mm Frame Fan Standard 89l/s, 320m
/hr FAN1043
Metric Size Description Order Code
125mm Finger Guard or FAN0397 - Metal FAN0412
125mm Finger Guard or FAN0397 - Plastic FAN1044
125mm Filter Guard or FAN0397 FAN0413
150mm Finger Guard or FAN1043 FAN0841
ACCESSORIES
This rame an is designed or use in computer rooms or applications wherethe introduction o cool air is required or small enclosed spaces
The ball bearing motor prolongs the lie o the motor Supported by a two year warranty For technical speciication reer page 73
Frame Fan 125mm
Year Warranty
-
7/23/2019 Fan Ventillation Calculations-HVAC
31/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au 29
Fan Accessories
Fan Timer
Transormers
Model No. Description Order Code
Time Air 7 Minute Fixed Timer (suits ans 20W-200W) FAN0372
A ixed an timer that will automatically switch the appliance o ater 7 minutes
Model No. Description Order Code
ACTO TE0060 Electronic Transormer 12VAC 50kHz FAN2101
This transormer must only be used with 12v lighting installations Supports lamp wattages rom 20W - 60W Overload & short circuit protection with sel resetting. Over temperature cut o Dimmable with trailing and leading edge dimmers
Humidistat ControllerModel No. Description Order Code
1360 Humidistat Controller FAN0963
Designed to operate the an when the relative humidity reaches apre-set level.
Fits a double pattress
This unit is adjustable between 20 - 90% RH
Model No. Description Order Code
TBA SELV Isolating Transormer 12VAC FAN2402
SELV isolating transormer is required or all low voltage an installations Can be used with low voltage 12v lighting Supports lamp wattages rom 20W - 50W An Iron Core Transormer Thermally stable and shatter-proo plastic casings Overload & short circuit protection with sel resetting Over temperature cut o Dimmable with trailing and leading edge dimmers
-
7/23/2019 Fan Ventillation Calculations-HVAC
32/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au30
ULTECON ThermostatsModel No. Description Order Code
TA01 Analogue Thermostat FAN0153
TD01 Digital Thermostat FAN0981TD02 Digital 2 Speed Thermostat FAN0982
TD03 Digital 3 Speed Thermostat FAN0983
High quality, easy to use thermostats Dual output switching or both cooling and heating situations Electronic temperature sensor Included in Heat Trans systems
A range o speed controllers with variable or 2 speed and reversible options Models 1348-1350: Electrical load must be between 20 and 200 watts FAN0154 - Single pattress mounting block or FAN0155/0156/0157*Not suitable or Manual Pull Cord Models
Speed Controllers
Model No. Description Switching Method Order Code
1348 For XF/XP/WF
230/300 Fans*
2 Spd + Reverse FAN0155
1349 For XF/XP/WF
230/300 Fans*
Adjust + Reverse FAN0156
1350 For any XF/XP/WF
230/300 Fans
Adjustable FAN0157
PDL625F General Purpose up to 500W On-O + Adjust FAN2104
Fan Accessories
Model No. Description InputCurrent
OutputPower
Order Code
SPC05 Ultecon 5 Speed Fan Controller 1A 100W FAN1096
ULTECON Speed Controller
5 speed an selection - manual or external control Enclosure can be wall mounted or ree standing On/O switch
Choice o ixed wired or lead and plug
Fan Mounting Brackets
These adjustable an mounting brackets, designed or use withthe centriugal ans
Supplied in pairs
Metric Size Description Order Code
100-200mm Fan Mounting Bracket or 100-200mm FAN0015
250-315mm Fan Mounting Bracket or 250-315mm FAN0016
-
7/23/2019 Fan Ventillation Calculations-HVAC
33/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au 31
Fully complies to AS4254 & AS4508 & AS1530 Pt3
DUCT CORE : Aluminium oil laminated onto polyester ilm, permanently bonded onto acorrosion resistant coated, spring steel wire helix
DUCT SLEEVE: Fire retardant 75m black low density polyethylene and UV stabilised DUCT INSULATION: AS4508 Polyester R0.6 nominal 250grams per mtr/sq 40mm thick
TEMPERATURE RANGE: Maximum: +150C : Minimum: -30C
COLOUR: Silver with black sleeve
See Friction Loss Graph on page 78
Ducting Installation Tips see pages 74 - 77
Ducting
Nude
Insulated
NUDE INSULATED
Diameter
(mm)
Length
(m)
Order Code Order Code
100136
DCT0357DCT0328DCT0409
125136
DCT0358DCT0329DCT0410
150136
DCT0359DCT0330DCT0411
DCT0088DCT0399
20036
DCT0331DCT0412
DCT0089DCT0343
250 36 DCT0332DCT0413 DCT0400
30036
DCT0380DCT0414
DCT0401
35036
DCT0415DCT0416
DCT0403
40036
DCT0417DCT0418
DCT0405
NOTE:
All 1 metre lengths are packed in bags with header cards, 3 metre nude duct is supplied boxed up to 250mm and all other items are supplied incolour coded bags.No glued/adhesive duct should be installed in a compressed or ovalised state for fear of long term failure.
ALUDUCT Flexible Ducting
INSULATEDR0.6
Diameter(mm)
Length(m)
Order Code
15036
DCT0633DCT0634
20036
DCT0635DCT0636
UNILOK FR1 Acoustic Ducting is a lexible duct manuactured tough & whisper quiet or consumer & installer peace o mind.Unlike other types o lexible duct, UNILOK FR1 has an outer steel rib that ensures the products integrity, and correct diameter,even in the tightest bends. Due to its steel rib, it is not prone to glue ailure or atigue (sagging or ovalisation) rom vibration withage like plastic ribbed or non ribbed glued duct.
UNILOK FR1 Acoustic Ducting
-
7/23/2019 Fan Ventillation Calculations-HVAC
34/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au32
Ducting
Fully complies to AS1530 Building code
DUCT CORE: Spiral wire reinorced PVC ilm construction. Non collapsing/Non rotting
Vapour-proo
Fire retardant
TEMPERATURE RANGE: Maximum: +50C : Minimum:6C
COLOUR: White PVC
Ducting Installation Tips see page 74 - 77
Diameter(mm)
Length(m)
Pack Order Code
100 13
Header CardedBoxed
DCT0936DCT0336
12514
Header CardedBoxed
DCT0937DCT0337
15015
Header CardedBoxed
DCT0938DCT0338
Diameter(mm)
Length(m)
Pack Order Code
1001.53
BoxedLoose
DCT0333DCT0114
1251.53
BoxedLoose
DCT0334DCT0115
1501.53
BoxedLoose
DCT0335DCT0116
200 3 Loose DCT0117
250 3 Loose DCT0118
300 3 Loose DCT0119350 3 Loose DCT0120
400 3 Loose DCT0477
Fully complies to the BCA
DUCT CORE: Pure aluminium spiral wound with a unique interlocked and knurled continuous seam
Holds shape, sel supporting
TEMPERATURE RANGE: Maximum: +250C, Minimum: -30C COLOUR: Silver
Ducting Installation Tips see page 74 - 77
P.V.C Flexible Duct is a product that is extremely versatile in the ventilation industry.It doesnt rot, is non collapsing, is ire resistant, has an operating temperature o +6deg to +50 deg and is available in a range o sizes rom 100mm to 150mm.
SEMIDUCT is also known as semi-rigid aluminium ducting is a lightweight, lexible but strongcorrugated aluminium duct. It is spiral wound with a unique interlocked and knotted continuous seam.It is sel supporting over longer lengths and generally only needs ittings or mechanics at each endor support.
PVC Flexible Ducting
SEMIDUCT Semi Rigid Ducting
-
7/23/2019 Fan Ventillation Calculations-HVAC
35/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au 33
Ducting
Low proile ducting enables it to be concealed when installed along the top o wall units.It can also be itted in ceiling voids and cavity walls, providing versatility whilst remainingunobtrusive. All Manrose system parts and channels are made rom lame-retardant material.
Fur Lw Prfile System Sies
110mm x 54mm:
Suitable or applications requiring low extraction rates, such as ventilation o domesticbathrooms and toilets. With a 5940mm cross-section it provides eicient ducting or short,straight runs connecting to a 100mm round spigot.
204mm x 60mm:
Suitable or ducting o kitchen cooker hoods with 100, 125 or 150mm round exhaust spigots.The lat channel cross section o 12240mm increases eiciency.
High Perormance 220mm x 90mm:
Suitable or applications requiring high perormance extraction or supply. The lat channelcross section o 19800mm makes it highly eicient and higher extraction rates are achieved.
Flat Ducting 300mm x 25mm:
Suitable or applications where space is very limited
Dimension(mm)
EquivalentSize (mm)
Length (m) Order Code
110 x 54 100 1.5 DCT0013
204 x 60 125 1.5 DCT0519
220 x 90 150 1.5 DCT1443
300 x 25 100 1.5 DCT1460
Diameter
(mm) Length (m) Finish Order Code
100 0.9 Galvanised DCT0151
100 0.9 White DCT0145
125 0.9 Galvanised DCT0152
125 0.9 White DCT0146
125 1.2 Galvanised DCT0953
150 0.9 Galvanised DCT0153
150 0.9 White DCT0147
150 1.2 Galvanised DCT0954
Diameter(mm)
Length (m) Finish Order Code
100 0.9 PVC DCT1424
125 0.9 PVC DCT1425
150 0.9 PVC DCT1426
Solid Tube - Rigid Steel
Solid Tube - White Plastic
Solid Tube
Low Proile Ducting - Flat Channel
-
7/23/2019 Fan Ventillation Calculations-HVAC
36/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au34
Duct Fittings
Rectangle Dimension (mm) Order Code
110 x 54 DCT0014
204 x 60 DCT0520
220 x 90 DCT1442
300 x 25 DCT1459
Low Proile Connectors
Rectangle Dimension (mm) Order Code
110 x 54 DCT1479
204 x 60 DCT1114
Horizontal T-Piece Connectors
Adaptors (Rectangular : Round)
Short Adaptors (Rectangular : Round)
(Designed to it 204 x 60mm lat channel or airbrick)
Flat Channel Reducer
Rectangle Dimension (mm) Round (mm) Order Code
110 x 54 100 DCT1482
204 x 60 125 DCT0526
220 x 90 150 DCT1446
300 x 25 100 DCT1461
Rectangle Dimension (mm)Round Diameter
(mm)Order Code
100 x 54 100 DCT0127 ()
110 x 54 100 DCT0131 (m)
Rectangle Dimension (mm) Order Code
110 x 54 : 204 x 60 DCT0136
204 x 60 : 220 x 90 DCT1452
204 x 60 : 300 x 25 DCT1456
(m) = Male
(f) = Female
Round Adaptor (Round : Round)
Round Diameter (mm) Order Code125 DCT0448
Low Proile Duct Fittings
-
7/23/2019 Fan Ventillation Calculations-HVAC
37/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au 35
Rectangle Dimension (mm) Order Code Order Code Order Code
110 x 54 DCT0124 (m)
110 x 54 DCT0015 ()
204 x 60 DCT0521 DCT0522 DCT0523
220 x 90 DCT1444 DCT1440* DCT1441*
300 x 25 DCT2095 DCT2096
HoRIzoNTAL VERTIcAL
Rectangle Dimension (mm) Order Code Order Code
110 x 54 DCT0125 DCT0126
204 x 60 DCT0524 DCT0525
220 x 90 DCT1448 DCT1447
300 x 25 DCT2097 DCT2099
HoRIzoNTAL VERTIcAL
Rectangle Dimension (mm) Order Code Order Code
300 x 25 DCT2098 DCT1455
*Rotating offset spigot
(m) = Male (f) = Female
100mm 125mm 150mm
Rectangle Dimension (mm) Order Code
204 x 60 DCT1480
90 Bends
45 Bends
Elbow Bends (Rectangular : Round)
Adjustable Horizontal Bend
Elbow Bend
Horizontal
Vertical45 Bend
Adjustable Horizontal Bend
Horizontal
Vertical90 Bend
Duct Fittings
*2 clips are required to secure ducting
A B
Flat Channel Clips
Rectangle Dimension (mm) Order Code
110 x 54 (A) DCT0134204 x 60 (A) DCT0527
220 x 90 (B) DCT1445*
300 x 25 (B) DCT1458*
Low Proile Duct Fittings
Designed to it directly into the round solid tube For systems ducted straight through an external wall
Metric Size (mm) Order Code
100 DCT2206
Standard external grille
Standard
-
7/23/2019 Fan Ventillation Calculations-HVAC
38/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au36
Duct Fittings
Round Diameter
(mm)
Square Dimension
(LxW mm) Order Code
104 155 x 155 DCT0148
130 170 x 170 DCT0149
160 200 x 200 DCT0150
Wall/Ceiling Plate - Round
Internal Dimension(LxW mm)
External Dimension(LxW mm)
Order Code
110 x 54 155 x 155 DCT0016
204 x 60 264 x 118 DCT0528
Wall/Ceiling Plate - Rectangle
Rectangle Dimension (mm) Order Code
220 x 90 : 232 x 138 DCT1451
Rectangle Dimension (mm) Order Code
232 x 138 DCT1450
The ollowing Reducer or Connector is required to connectthe Airbrick insert to the Duct:
110 x 54mm: requires Reducer order code: DCT0136
Rectangle Dimension (mm) Airbrick Direction Order Code
204 x 60 Horizontal DCT0137
204 x 60 Vertical DCT1414
Double Airbrick Adaptor
Double Airbrick
Double Airbrick Reducer
Airbrick Insert (204 x 60mm)
(W)
(L)
Rectangle Dimension (mm) Order Code
235 x 140 DCT1453
Low Proile Duct Fittings
-
7/23/2019 Fan Ventillation Calculations-HVAC
39/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au 37
Branch Take-Os (BTO)
Duct Fittings
METALPoLY
Metric Size (mm) Order Code Order Code Order Code
125-100 DCT2067
150-100 DCT2122
150-125 DCT2066
200-125 DCT0084
200-150 DCT0486
NOTE:Products with the order code showing are generally ex. stock lines - other products are available to order
PVc
PVC Plastic
Reducers
*DCT0159isaPVCductjoiner
METALLoNG
METALSHoRT
METAL PLATESPIGoTS
Metri Sie (mm) Order Code order cde order cde order cde
100 DCT0159*
125 DCT0037
150 DCT0723 DCT0059 DCT0935
200 DCT0724 DCT0071 DCT0939
250 DCT0725 DCT0339 DCT0940
PoLY
Metal Long Metal Short
Metal Plate Spigots
Duct Joiners/Spigots
ManufacturedfromHDPE,U.V.stabilised
Heavyduty,robust,smoothinternallines
Nosharpedges,Positivelockducttabs
InsulationmeetsAS1530part3
InsulationmaterialLDPE,thickness5mm
PoLY INSULATED
Metric Size (mm) Order Code Order Code
100-100-100 DCT1439
125-125-125 DCT1501
150-150-150 DCT0091 DCT0875
200-150-150 DCT0719 DCT0876
200-200-150 DCT0460 DCT0877
-
7/23/2019 Fan Ventillation Calculations-HVAC
40/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au38
EGGcRATE GRILLES
Metric Size (mm) Colour Order Code
100 White DCT0375
125 White DCT0472
150 White DCT0473
Improved air-low characteristics
Removable insert or easy cleaning
Metric Size (mm) Colour Order Code
100 White DCT0025100 Grey DCT0024
100 Terracotta DCT0026
125 White DCT0041
125 Grey DCT0039
125 Terracotta DCT0040
150 White DCT0063
150 Grey DCT0062
150 Terracotta DCT0064
200 White DCT0340
230/250 White DCT0073
300 White DCT1979
FIxED LoUVRE GRILLES
GRAVITY GRILLES
Metric Size (mm) Colour Order Code
100 White DCT0029
100 Grey DCT0028
100 Terracotta DCT0027
125 White DCT0044
125 Grey DCT0042
125 Terracotta DCT0043
150 White DCT0066
150 Grey DCT0061
150 Terracotta DCT0065
230/250 White DCT2204300 White DCT1981
Standard grille with someweather protection
Removable insert or easy cleaning
Prevents back draughts &weather penetration
Metric Size (mm) Colour Order Code
100 Stainless Steel DCT2145
125 Stainless Steel DCT2146
150 Stainless Steel DCT2147
DESIGNER SERIES GRAVITY GRILLES
High quality designer stainlesssteel inish
Technical data see page 79
Technical data see page 81
Fixed Wall Ceiling Grilles
Gravity Wall Grilles
Grilles & Diusers
-
7/23/2019 Fan Ventillation Calculations-HVAC
41/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au 39
Low Proile eggcrate design improves airlow in extraction applications
Twist lock ascia or easy cleaning
Gib ixing clips included
Longer spigot or easy duct connection Satin Silver & Chrome ascias available see page 12 or 15
Technical data see page 79
ACCESSORIES
Accessories
Metric Size (mm) Description Colour Order Code
100 Circular White DCT1089100 Square White DCT2223
125 Circular White DCT1090
125 Square White DCT2224
150 Circular White DCT1067
150 Square White DCT2225
Metric Size (mm) Description Colour Order Code
125 Circular Fascia White FAN0748
125 Square Fascia White FAN0747
150 Circular Fascia White FAN0750
150 Square Fascia White FAN0749
125 Spigot Black DCT1074
150 Spigot Black FAN0656
Low Proile Wall/Ceiling Grille
Grilles & Diusers
High quality designer inish available in either white or brushed aluminium silver
Designed or bathroom extraction that blends into any decor
Technical data see page 79
Metric Size (mm) Colour Order Code
150 White DCT2236
150 Silver DCT2237
DESIGNER SERIES SQUARE WALL/cEILING GRILLE
Square Wall/Ceiling Grille
-
7/23/2019 Fan Ventillation Calculations-HVAC
42/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au40
Grilles & Diusers
Manuactured rom A.B.S plastic
Designed or either supply or extract ventilation
Fixing lange included, screws required
Adjustable screw in centre cone
Technical data see page 80
Metric Size (mm) Colour Order Code
100 White DCT0020
125 White DCT0174150 White DCT0058
200 White DCT0068
ECO Ceiling Diuser
Concentric circular grille designed or extraction
Technical data see page 79
Metric Size (mm) Colour Order Code
100 White DCT2185
125 White DCT2186
150 White DCT2187
Circular Wall/Ceiling Grille
FIxED LoUVRE VENT
Plate Sie (mm) clur order cde
245 x 80 White DCT2194
245 x 80 Chrome DCT2195
245 x 160 White DCT2196
245 x 160 Chrome DCT2197
245 x 245 White DCT2198
245 x 245 Chrome DCT2199
ADjUSTAbLE VENTPlate Sie (mm) clur order cde
245 x 80 White DCT2188
245 x 80 Chrome DCT2189
245 x 160 White DCT2190
245 x 160 Chrome DCT2191
245 x 245 White DCT2192
245 x 245 Chrome DCT2193
Manuactured rom PVC in either white or chrome inish
Designed or use when make-up air is required Fixed Louvre provides maximum airlow
Adjustable Vent can be ully closed o when not required
Wall/Ceiling Plate Vents
-
7/23/2019 Fan Ventillation Calculations-HVAC
43/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au 41
Grilles & Diusers
Manuactured rom ABS plastic
Designed or either supply or extract ventilation
When used to supply, the air will be pushed down into the room
These diusers are designed or use in heat transer systems(reer to page 46-49)
Spring loaded ixing clips
Resistant to scratching and ading
Positive lock duct tabs
Adjustable screw in centre cone to ensure a balanced airlow
Technical data see page 80
Metric Size (mm) Colour Order Code
150 White DCT1472
200 White DCT1473
250 White DCT1474
300 White DCT1475
High quality designer inish
Designed to supply air into your home, by pushing the airalong the ceiling and down the walls. Suitable or use inhome ventilation systems
Technical data see page 80
Metric Size (mm) Colour Order Code
150 White DCT2208
High quality designer stainless steel inish
Designed or internal extraction where a quality inish is required
Technical data see page 80
Metric Size (mm) Colour Order Code
100 Stainless DCT2139
125 Stainless DCT2140
150 Stainless DCT2141
DESIGNER SERIES cEILING DIFFUSERS
Stainless Steel Ceiling Diuser
Low Proile Flat Ceiling Diuser
Cone Ceiling Diuser
-
7/23/2019 Fan Ventillation Calculations-HVAC
44/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au42
High quality designer stainless steel inish
Designed or use where adverse weather conditions are experienced
Manuactured rom a 304 grade stainless steel
Technical data see page 81
Metric Size (mm) Colour Order Code100 Stainless Steel DCT2151
125 Stainless Steel DCT2152
150 Stainless Steel DCT2153
Metric Size (mm) Colour Order Code
100 Stainless Steel DCT2157
125 Stainless Steel DCT2158
150 Stainless Steel DCT2159
Used where adverse weather conditions are experienced
Technical data see page 81
Metric Size (mm) Colour Order Code
100 White DCT0018
100 Brown DCT0019
125 White DCT1030
150 White DCT1031
WEATHERPRooF coWL
DESIGNER SERIES WEATHERPRooF coWL
DESIGNER SERIES WEATHERPRooF DoME coWL
High quality stainless steel dome cowl or a modern stylish look
Designed or exhaust and supply ventilation
Generally mounted on an external wall, however they can be mounted internally Manuactured rom a 304 grade stainless steel
Insect mesh included
Technical data see page 81
Weatherproo Cowl
Weatherproo Dome Cowl
Grilles & Diusers
Model No. Desriptin order cde
Door Vent Internal Door Ventilator Grille FAN0159
This door grille allows make-up air into the room
Dimensions: 455mm(h) x 90mm(w) to it door with depth o 33mm
Door Grille
-
7/23/2019 Fan Ventillation Calculations-HVAC
45/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au 43
Thru Roo Mounted Cowls/Kits
General Purpose Cowl - Low proile
Low back pressure
Heavy Duty Cowl - Aluminium construction- Added exhaust aperture area and deep vent coverage- Recommended where high winds in exposed locations may drive rain into the vent- Also recommended or use in high airlow air intake systems to prevent rain
being sucked into the system
Technical data see page72
Metric Size (mm) Description Order Code
150 General Purpose Cowl DCT0708
150 Heavy Duty Cowl DCT0709
Roo Cowls
Metric Size (mm) Description Order Code
150 General Purpose Kit DCT0172
150 Heavy Duty Cowl Kit DCT0710
150 General Purpose Lead Flashing Kit DCT1095
General purpose cowl included
0.5m HDPE Tube included
Dektite included (or metal based roos)
All ittings supplied Optional lead Dektite available (extra cost - reer to Roo Flashings page 39)
NB: Lead Dektite (DCT0190) required or concrete tile roos
Reducers it to the bottom o HDPE tube to adapt to smaller duct diameters where required
Plastic Reducers or HDPE Thru-Roo Tube (or thru-roo kits)
Metric Size (mm) Description Order Code
150:125 150:125 reducer DCT2066
150:100 150:100 reducer DCT2122
Metric Size (mm) Description Order Code
100 Angled Roof Kit DCT2205
General purpose through roo kit or smaller application
To be mounted on tile roos
Complete kit - Cowl, 0.5m o tube & weathering slate included
Roo Cowl Kits with Dektite & HDPE Tube
Angled Roo Cowl Kit
-
7/23/2019 Fan Ventillation Calculations-HVAC
46/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au44
Rangehood Ducting Kits
Metric Size (mm) Description Order Code
150 Thru-Soffit Kit DCT2323
Thru Soit Kits
Thru Roo Kits
Metric Size (mm) Description Order Code
150 Thru-Roof Kit (with Dektite Flashing) DCT2324
150mm x 3m Aluminium Duct
1 x 150/125mm Round Reducer
1 x 150mm Duct Joiner
1 x 150mm Eggcrate Grille
3m Semi Rigid Duct
All ittings and ixings
Metric Size (mm) Description Order Code
150 Thru-Wall Kit DCT2592
Thru Wall Kits
1 x 150mm Weatherproo Cowl
150mm x 1.5m Rigid Duct
All ittings and ixings
150mm x 3m Aluminium Duct
1 x 150/125mm Round Reducer
1 x 150mm Duct Joiner
Metric Size (mm) Description Order Code
150 Thru-Roof Kit (with Lead Flashing) DCT2325
150mm x 3m Semi Rigid Duct
150mm Roo Cowl
1 x 600m Metal Strap
1 x 150/125mm Reducer
1 x 150mm Duct Joiner
2 x 150mm x 0.9m Galvanised Tube
1 x 150mm Dektite Flashing
All ittings and ixings
150mm x 3m Semi Rigid Duct
150mm Roo Cowl
1 x 600m Metal Strap
1 x 150/125mm Reducer
1 x 150mm Duct Joiner
2 x 150mm x 0.9m Galvanised Tube
1 x 150mm Lead Flashing
All ittings and ixings
-
7/23/2019 Fan Ventillation Calculations-HVAC
47/92
Ph: 1300 666 595 Fax: 1300 666 594 Email: [email protected] Website: www.manrose.com.au 45
Duct Accessories
Insect Mesh
Metri Sie (mm) Desriptin order cde
100 For 100mm Grilles DCT0371
125 For 125mm Grilles DCT0208
150 For 150mm Grilles DCT0207
250 For 200mm & 250mm Grilles DCT0373
150 Bird Mesh DCT2263
Duct Straps and Duct Tape
*AS4254 Duct tape DCT1132
- Temperature range -37C - 127C AS4254 Duct Tape
Ducting Straps & Duct Tape
Metric Size (mm) Desriptin order cde
100mm Ducting Strap FAN0274
125mm Ducting Strap FAN0281
150mm Ducting Strap FAN0282
12mm x 3m Hanging Strap DCT2299
25mm x 50m Hanging Strap DCT0808
48mm x 5m Duct Tape DCT0173
48mm x 30m Duct Tape DCT0807
48mm x 60m Duct Tape - *AS4254 DCT1132
Description Order Code
Dektite Roof Flashing - fits 110-160mm DCT0180
Tiledek Roof Flashing - For use on concretetile, clay tile and