Fall Protection Systems Latchways Plc James Sainsbury
Transcript of Fall Protection Systems Latchways Plc James Sainsbury
![Page 1: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/1.jpg)
Fall Protection Systems
Latchways Plc
James Sainsbury
![Page 2: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/2.jpg)
Introduction
Aims: To explain why you need a fall
protection system, the alternatives
available and how they work.
Objectives: To provide an understanding of the
key considerations for specification.
Outcome: To ensure you comply with the
legislation and your fall
protection system is integrated into the
building design.
![Page 3: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/3.jpg)
History of Latchways
![Page 4: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/4.jpg)
Latchways Products
Standard Transfastener Inclined Transfastener
TowerLatch Transfastener Removable Transfastener
![Page 5: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/5.jpg)
Work at Height Regulations 2005
& 2007 Updates
![Page 6: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/6.jpg)
Highlights of the new regulations
• Bring all current laws together into one place.
• Applies to ALL industries, not only construction.
• Employers and designers now face a more stringent legal duty to prevent accidents from construction thru to end user maintenance.
• The 2m Rule had been omitted, safety now begins from below the ground up.
• Appoints a bespoke job role (CDM Co-ordinator).
![Page 7: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/7.jpg)
Fall Protection Hierarchy
![Page 8: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/8.jpg)
Hierarchy of Fall
Protection
![Page 9: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/9.jpg)
Collective Systems
System type
depends on:
• Number of
workers
• Frequency of
use
• Time on roof
• Experience
![Page 10: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/10.jpg)
Typical Layouts
B1
(Fall Restraint)
B2 (Fall Arrest) Standard PPE, no adjustment.
![Page 11: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/11.jpg)
Typical Layouts
B3
(Fall Arrest)
High user
competency
Fall heights
image
![Page 12: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/12.jpg)
Traditional Load
Control
• Load control is the key
consideration in fall arrest
system design
• Traditionally loads have
been dissipated through
the structure of the
building
• Latchways revolutionised
the process by absorbing
load within the system
not the structure
![Page 13: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/13.jpg)
Latchways Constant Force
System for Roofing
Load Control
![Page 14: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/14.jpg)
Constant Force Post
Testing
Competitor Post
Testing
Load control cont’d
![Page 15: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/15.jpg)
Constant Force Post
Testing
1. Dynamic Testing
Worst Case
=
1
2
3
2. Static Load Testing
Safety Factor of 2 for 3 Mins
=
![Page 16: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/16.jpg)
Constant Force® post Product Range
Standing Seam
Secret Fix Membrane
Composite & BUOS
![Page 17: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/17.jpg)
Freestanding Post
• No Roof alterations.
• Working buildings.
• Part L legislation.
• Good for refurbishments projects.
• Natural evolution of the Constant Force post.
![Page 18: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/18.jpg)
WalkSafe ®
![Page 19: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/19.jpg)
VersiRail ®
![Page 20: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/20.jpg)
Life Cycle Costs
• Expect 25 year guarantees with components manufactured from stainless steel.
• Ensure ongoing annual maintenance inspections are undertaken.
![Page 21: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/21.jpg)
Why choose Latchways?
• World leader – Established – Secure
• Worldwide Network of Installers
• System Guarantees and Relationships with
Major Manufactures, Sarnafil, Corus Kalzip,
Kingspan, Bauder, Wards etc.
• Wide Product Range & Services
• Innovative – We set the standards
• Investment in quality components & resource
• Testing Regime – Exceed standards BS EN795
• Compliance and Compatibility i.e CE Marked.
![Page 22: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/22.jpg)
Summary and Objectives
As a result of the presentation you should:
1. appreciate how you can comply with the legislation
2. understand the key issues involved in system specification
3. consequently specify the right type of system.
![Page 23: Fall Protection Systems Latchways Plc James Sainsbury](https://reader031.fdocuments.us/reader031/viewer/2022021120/6206084ccf456418c32f2472/html5/thumbnails/23.jpg)
Fall Protection Systems
Latchways Plc
Thankyou