Facilities Plan Update

25
Facilities Plan Update October 14, 2009 Palmer Engineering Company / Hazen & Sawyer / CDP Clark County Fiscal Court Presentation

description

Facilities Plan Update. Clark County Fiscal Court Presentation. October 14, 2009. Palmer Engineering Company / Hazen & Sawyer / CDP. What is a Facilities Plan?. Required by the Federal and State Government 401 KAR 5:006 The Clean Water Act, 33 USC 1313 The Clean Water Act, 33 USC 1288 - PowerPoint PPT Presentation

Transcript of Facilities Plan Update

Page 1: Facilities Plan Update

Facilities Plan Update

October 14, 2009Palmer Engineering Company / Hazen & Sawyer / CDP

Clark County Fiscal Court Presentation

Page 2: Facilities Plan Update

What is a Facilities Plan?

Required by the Federal and State Government 401 KAR 5:006 The Clean Water Act, 33 USC 1313 The Clean Water Act, 33 USC 1288

Requirements 401 KAR 5:006

Page 3: Facilities Plan Update

Facilities Plan Requirements

Facilities Plan Boundary Existing Facilities Population Projections (20 Yrs) Flow Projections (20 Yrs) Environmental Considerations Alternatives Analysis Schedule

Page 4: Facilities Plan Update

Why Does WMU Need a Facilities Plan Update?

Required when: (401 KAR 5:006) Major changes to the Facilities 20 Years since previous Facilities Plan Current Facilities Plan: 1972 / 1973 Consent Decree

Page 5: Facilities Plan Update

Facilities Plan Approval Process

• Draft Plan• Clearinghouse Comments• Resubmit• Local Agency Approval• Public Hearing• Final Approval

Page 6: Facilities Plan Update

Environmental Agency Involvement

U.S. Department of Fish and Wildlife Kentucky Department of Fish and Wildlife Kentucky Heritage Council Kentucky State Nature Preserves Commission Kentucky Department for Environmental

Protection State Clearinghouse

Page 7: Facilities Plan Update
Page 8: Facilities Plan Update
Page 9: Facilities Plan Update
Page 10: Facilities Plan Update

WMU Existing Facilities

Includes: 150 miles of gravity sanitary sewer 15 Miles of Force Main 17 Pump Stations 1 WWTP

7.2 MGD (Average) 24 MGD (Peak)

1 Class A Bio-solids facility

Page 11: Facilities Plan Update

Existing Facilities Condition Aging Infrastructure (I/I) 27 Recurring Sanitary Sewer Overflows (SSOs)

Licking River Watershed – 14 Kentucky River Watershed – 13 Pump Station SSO Locations – 5 Manhole SSO Locations – 21 SC-WWTP SSO Locations – 1

Watersheds 2 River 14 Sub-watersheds Licking River - 8 Kentucky River - 6

Page 12: Facilities Plan Update
Page 13: Facilities Plan Update

Population Projections

Census Data University of Louisville Data Center Comprehensive Plan WMU Database

Page 14: Facilities Plan Update

Flow Projections

Customer Data Flow Monitoring WWTP Flow Data

Page 15: Facilities Plan Update

20 Year Flow Projections

Avg. DayPeak Day

• Licking River 7.2 MGD 24.0 MGD

• Kentucky River 2.0 MGD 10.0 MGD

Page 16: Facilities Plan Update

Alternatives Considered

• Single Treatment Plant• River Watershed Treatment Plants (2)

Page 17: Facilities Plan Update
Page 18: Facilities Plan Update
Page 19: Facilities Plan Update
Page 20: Facilities Plan Update

Alternatives Evaluated

• Capacity Requirements• Environmental Considerations• Constructability• Implementability• Cost

• Capital / O&M / Present Worth

• Recommended Alternative• River Watershed Treatment Plants (2)

Page 21: Facilities Plan Update
Page 22: Facilities Plan Update
Page 23: Facilities Plan Update

Discharge Alternatives

• Deep Branch Discharge• Kentucky River Discharge

Recommended Discharge Alternative• Kentucky River Discharge

Page 24: Facilities Plan Update

Schedule / Costs

Project Year Costs1. LHC Improvements 2013 $37,000,0002. Maryland Avenue, Wabash, & 2012 $1,500,000

Smith Manor PS3. Bel-Air & Westside PS 2013 $900,0004. East Interceptor Improvements 2021 $1,950,000

(Madison / Washington / Flanagan Ave.)5. Hood Creek Int. / PS / FM TBD $5,800,0006. Hancock Creek Int. / PS / FM TBD $8,800,0007. West Interceptor TBD $7,700,000

Page 25: Facilities Plan Update

Summary

• Required Element• Sets Direction• Consent Decree Compliance• Position for the Future