Page 2: F-Gaz Regulation - Implementation in France

І Content

• Cemafroid in a few words

– Independent cold chain expertise

French F-Gaz implementation

– Overview of French regulations

– The main requirements

DATAFLUID a centralized computing system

– A public platform

– Link between all actors

• Conclusion

Page 3: F-Gaz Regulation - Implementation in France

Cemafroid in a few words and data

Page 4: F-Gaz Regulation - Implementation in France

ІCemafroid : refrigeration experts

• 60 years of history

– 1950 creation of Antony laboratory

– 1970 Antony official ATP test station for UN

– 1980 creation of Cemagref

– 2000 creation of Cemafroid by Cemagref

– 2010 creation of Cemafroid group, TECNEA

and Cemafroid formation

• An independant company owned by:

– Cemagref : public research center

– PERIFEM distribution technical association

– TRANSFRIGOROUTE France association

– Cemafroid Staff : TECNEA

• Income : 4,1 M€ in 2010

– +25% in 2010

In a few words and data

Essais 36%

Cerification 27%

Expertise

6%

DSP 31%

Répartition du CA 2009

274 495 €

1 006 164 €

992 739 €

1 133 733 €

1 552 306 €1 638 676 €

1 862 312 €

2 148 042 €

2 240 860 €

3 310 000 €

4 030 000 €

- €

500 000 €

1 000 000 €

1 500 000 €

2 000 000 €

2 500 000 €

3 000 000 €

3 500 000 €

4 000 000 €

4 500 000 €

2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010

CA annuel du Cemafroid

Page 5: F-Gaz Regulation - Implementation in France

Arras• Service public

Bordeaux• Tests

Antony•Direction• Tests• Certification• Expertise

ІCemafroid• More than 40 staff

– 32 technical experts

• 3 locations

– Cestas (Bordeaux) (33)

– Fresnes (94) & Antony(92)

(Paris)

– Arras (62)

Staff, equipment,

and locations

• Laboratories and equipments

Fresnes

Page 6: F-Gaz Regulation - Implementation in France

ІCemafroid activities

-Cemafroid Performance

-PIEK Certification

-Tests Centers

-Certificate of Capability

-F-Gas

-Measuring equipment

-Performance

-Conformity

-Qualification

-Calibration

-Verification

-Comparative tests

-Validation

-Audit

-Technical assistance

-F-Gas

-Carbon Footprint

-Energy optimization

-Competent Authority

-Datafrig

-ATP

-Innovation

-Cold Chain & Hygiene

-Metrology & Instrumentation

-Cold, Security and Environment

Certification of products,

services and companiesTests, Calibration, Verification Expertise, Counsels

Public Service Training

Page 7: F-Gaz Regulation - Implementation in France

ІLe Cemafroid

• Laboratories accreditation

– Tests : Cofrac Essais ISO 17025,

– Tests : WHO/OMS – PQS

– Verifications : Cofrac Étalonnage ISO 17025

• Designation

– UNO – UNECE : ATP Test Station and ATP

Competent Authority

– Ministeries : Agriculture, Health, Defense,

Environment, Industry, …

• Networks

– IIF, Transfrigoroute, CEN, ISO,

– AFF, SFSTP, CNM,

Accreditations

Page 8: F-Gaz Regulation - Implementation in France

F-Gaz implementation

French regulations

Page 9: F-Gaz Regulation - Implementation in France

ІF-Gaz regulation• Concerns

– CFC - HCFC - HFC –

– All equipments including

– refrigerated transport,

– cars air conditionning…

• Obligations:

– Etancheity Controls over 2 kg

– Companies certification

• To buy and manipulate any F-Gazes

– Staff certification

• Even for etancheity control

– Traceability of all operations

• Load, installation, controls…

– Reporting and control

• stocks, leakages, usage, …

Framework

Page 10: F-Gaz Regulation - Implementation in France

ІF-Gaz regulationFrench system overview

Opérateur /

Company siteOrganisme agréé

Ministery

Agrément

Attestation d’aptitude

Evaluation body Certification body

COFRAC

Accreditation

Certification

Equipment owner or user, PAC, refrigeration device, Air conditionning, car…

Control

StaffEquipment

F-Gaz

distributor

ADEMEreport

report

Leakage

report

Ministery

local authority

Page 11: F-Gaz Regulation - Implementation in France

ІF-Gaz regulation in FranceCategories of operators

Etancheity

control

Maintenance

Support

Installation F-Gaz

recovery

Catégorie I All equipments refrigeration, air conditionning heat pumps

Catégorie II All equipments

refrigeration,

AC, HP

All equipments refrigeration, AC, HP with less

than 3kg F-Gaz

Catégorie III All equipments

refrigeration,

AC, HP with

less than 3kg

F-Gaz

Catégorie IV All equipments

refrigeration,

AC, HP

Catégorie V All equipments for air conditionning for vehicles

(cars, trucks, bus, all equipments going on the road)

Page 12: F-Gaz Regulation - Implementation in France

ІF-Gaz regulation

Operator

Certified people working for certified

companies

Attestation d’aptitude /

Staff certificate

Attestation de capacité

/ Company certificate

Page 13: F-Gaz Regulation - Implementation in France

ІF-Gaz regulation

Operators

Agrément

Company certificate

Condition n°1 :

Equipment

since 4th of July 2009

Charge station

Bottles

Leakage detector

Flexibles and obturators

Manometers; thermometres

Identification devices

List linked with the activity of the company

Vérifié selon la

norme NF EN 35421

Conforme à la NF

EN 14624Précision 5%...

Ministery

Organisme agréé

Opérateur /

Company site

Page 14: F-Gaz Regulation - Implementation in France

ІF-Gaz regulation

Minister

Organisme agréé

Opérateur /

Company site

Agrément

Attestation de capacité /

company certificate

Personnal certificate

Evaluation body

Certification

bodyCOFRAC

Accreditation

Certification

Condition n°2

Competent staffSince 5th of July 2011

Page 15: F-Gaz Regulation - Implementation in France

ІF-Gaz regulation

Agreement

Company certificate

Condition n°3

F-Gaz containement and

treaceabilitySince 4th of July 2009

Operation traceability

Operation report

F-Gaz annual Reporting

Etancheity certificate

Ministery

Organisme agréé

Opérateur/

Company site

Page 16: F-Gaz Regulation - Implementation in France

ІF-Gaz regulationPeriodical controls

F-Gaz load Controls

> 2 kg Once a year

> 30 kg Every 6 month

> 300 kg Every 3 month

When a ambiance detector is installed frequency can be devided by 2

Page 17: F-Gaz Regulation - Implementation in France

DATAFLUIDES

A centralised computing system

Page 18: F-Gaz Regulation - Implementation in France

Datafluides®

First contact with

« Organismes Agrees »

Direct acces to

regulation

Last news

Private acces for

certificate

management

Public list of

operators

Page 19: F-Gaz Regulation - Implementation in France

Declare company

elements

Siège social

Région 1

Région 2

Région 3

SIRET 1

SIRET 2

SIRET 3

SIRET 4

SIRET 5

SIRET 7

Accès selon profils à

Datafluides

Page 20: F-Gaz Regulation - Implementation in France

Declare staff

Affect the staff to the

sites

Move people from one

site to another

Declare their

certification

Withdraw them.

Page 21: F-Gaz Regulation - Implementation in France

Overview of demand

Page 22: F-Gaz Regulation - Implementation in France

ІF-Gazes operators

French figures January 2011

40%

2%1%1%

56%

Cat 1 Cat 2 Cat 3 Cat 4 Cat 5

• Companies certificates :

« Attestation de capacité »

– Catégorie I à IV : 11 208

– Catégorie V: 16 291

– Some 70%

• People certificates :

« Attestation d’aptitude »

– Catégorie 1: 13 836

– Catégorie 2: 19 721

– Some 33%

Page 23: F-Gaz Regulation - Implementation in France

ІDATAFLUIDES fonctionalities

OR

GA

NIS

ME

AG

RE

E

Anonyme

Opérateur

candidat

Abonnement à consultations détaillées Consultation espace public Inscription, choix d’un organisme agréé,

demande de devis, renseignement pré-dossier

Création compte opérateur candidat

Validation commande valant

demande d’attestation

Invitation à renseigner le

dossier de candidature

Envoi devis

Renseignement dossier de

candidature

Recevable

Edition attestation, et enregistrement

statut sur DATAFLUIDES

Si non

Demande complément

d’information

Saisie annuelle fiche fluides

Renouvellement

Suspension

Audit dans les 5 ans Si défavorable

Opérateur

habilité

Opérateur

candidat

HABILITATION

Si non

Suspension

HABILITATION

Page 24: F-Gaz Regulation - Implementation in France

French disposal system

and its funding

Page 25: F-Gaz Regulation - Implementation in France

ІThe French disposal system

• Collect and recycle and destroy F-Gazes

– In the frame of a national convention

– Managed by professional associations

• Collect system

• Equipments owned and operated by

distributors

• Treatment

• Done by the distributors and producers

• Payment

• A fee on each F-Gaz kg distributed

• a payment for dedicated bottles rental

• A payment of a prime for collect

Since 1993

Page 26: F-Gaz Regulation - Implementation in France

ІThe French disposal system

A new system

Eco-organisme

Eco-fluides

Distributeurs de

fluides

MEDDTL

ADEME

Opérateurs attestés

manipulant des fluides

frigorigènes Flux de fluides

Flux financiers

Flux de données

Flux d’informations

Audits de contrôle

Organisations

professionnelles

Page 27: F-Gaz Regulation - Implementation in France

Conclusion

Page 28: F-Gaz Regulation - Implementation in France

ІConclusion

• F-Gaz issues are transversal

– No reason to exclude some activities

– Neither actors

• Process is long to implement

– Step by step process is necessary

– Control is also imperative

– international harmonization should increase

• A global computing tool online is a plus

– For everybody

– Cost and time saving project

– Traceability insurance

Page 29: F-Gaz Regulation - Implementation in France

ІThank you for your attention !

For more detailled information, please contact us :

Gérald CAVALIER

Cemafroid

5, avenue des Prés,

94 266 Fresnes cedex France

www.cemafroid.fr

Tel : 01 49 84 84 84

[email protected]

Independent expertise and testing for cold chain