Eye & Vision Consortium - UK Biobank · Eye & Vision Consortium ... • Autorefraction &...

20
UK Biobank Eye & Vision Consortium Paul Foster UCL Professor of Ophthalmic Epidemiology & Honorary Consultant Ophthalmologist UKBAM 2016 QEII Conference Centre Monday 13 th June 2016 NIHR BRC @ Moorfields & UCL Institute of Ophthalmology

Transcript of Eye & Vision Consortium - UK Biobank · Eye & Vision Consortium ... • Autorefraction &...

Page 1: Eye & Vision Consortium - UK Biobank · Eye & Vision Consortium ... • Autorefraction & keratometry • Intraocular pressure • Corneal biomechanics On 87,642 people • Retinal

UK Biobank

Eye & Vision Consortium

Paul Foster

UCL Professor of Ophthalmic Epidemiology

& Honorary Consultant Ophthalmologist

UKBAM 2016 – QEII Conference Centre

Monday 13th June 2016

NIHR BRC @ Moorfields & UCL Institute of Ophthalmology

Page 2: Eye & Vision Consortium - UK Biobank · Eye & Vision Consortium ... • Autorefraction & keratometry • Intraocular pressure • Corneal biomechanics On 87,642 people • Retinal

www.moorfields.nhs.uk

Why Do Eyes Matter?

• The population is aging

• In people aged >/= 75 years

• 10% are partially sighted

• 2% are blind

• In 2009-10, there were 5.95 million patient

visits to UK eye departments (7.1% of total)

• Each year, 330,000 cataract operations are

performed

Page 3: Eye & Vision Consortium - UK Biobank · Eye & Vision Consortium ... • Autorefraction & keratometry • Intraocular pressure • Corneal biomechanics On 87,642 people • Retinal

Eyes and Vision in UKBB • Moorfields/UCL invited to design

eye module – 10 minutes maximum – £500,000/minute

• Piggy-backed eye study – Visual acuity – Auto-refraction – IOP/Corneal biomechanics – Fundus photo/OCT

Page 4: Eye & Vision Consortium - UK Biobank · Eye & Vision Consortium ... • Autorefraction & keratometry • Intraocular pressure • Corneal biomechanics On 87,642 people • Retinal

UKBB Eye and Vision Data

Standard measure of vision

used to assess

- Fitness to drive

- Suitability for cataract

surgery

- “Sight impaired” status

- Linked to mortality rate

Page 5: Eye & Vision Consortium - UK Biobank · Eye & Vision Consortium ... • Autorefraction & keratometry • Intraocular pressure • Corneal biomechanics On 87,642 people • Retinal

UKBB Eye and Vision Data

Autorefractor

Measures

• Spectacle

prescription

• Curvature of the

cornea

Page 6: Eye & Vision Consortium - UK Biobank · Eye & Vision Consortium ... • Autorefraction & keratometry • Intraocular pressure • Corneal biomechanics On 87,642 people • Retinal

Eye Pressure and Corneal Biomechanics

UKBB - IOP Method

Eye pressure is the major modifiable

risk factor for glaucoma

Corneal biomechanics influences

accuracy of IOP measures

Cornea is 90% collagen

Page 7: Eye & Vision Consortium - UK Biobank · Eye & Vision Consortium ... • Autorefraction & keratometry • Intraocular pressure • Corneal biomechanics On 87,642 people • Retinal

Applanation Signal Plot Signal Plot

UKBiobank- IOP Method

Page 8: Eye & Vision Consortium - UK Biobank · Eye & Vision Consortium ... • Autorefraction & keratometry • Intraocular pressure • Corneal biomechanics On 87,642 people • Retinal

UKBB Eye and Vision Data

Page 9: Eye & Vision Consortium - UK Biobank · Eye & Vision Consortium ... • Autorefraction & keratometry • Intraocular pressure • Corneal biomechanics On 87,642 people • Retinal
Page 10: Eye & Vision Consortium - UK Biobank · Eye & Vision Consortium ... • Autorefraction & keratometry • Intraocular pressure • Corneal biomechanics On 87,642 people • Retinal
Page 11: Eye & Vision Consortium - UK Biobank · Eye & Vision Consortium ... • Autorefraction & keratometry • Intraocular pressure • Corneal biomechanics On 87,642 people • Retinal

www.moorfields.nhs.uk

•Macular OCT images were available for processing

from 134,642 eyes of 67,321 patients.

•134,611 images were successfully processed with 31

images failing (success: 99.98% of images).

•Average time taken to process each images was 128

seconds.

UK Biobank - a new age for ophthalmic epidemiology

Feasibility of Rapid, Automated Analysis of Macular Thickness in a Population Study: Approach to Analysis of Spectral-domain OCT Images from 67,321 Subjects in the UK Biobank Study

Patel PJ,1 Keane PA,1 Grossi CM,1 Foster PJ, 1 Yang Q,2 Chang CY,2 Reisman CA,2 Chan K2

1NIHR Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, UK 2Topcon Advanced Biomedical Imaging Laboratory, Oakland, NJ, USA

Program #670 - C0080

Patel, Keane, Grossi – ARVO 2014

Page 12: Eye & Vision Consortium - UK Biobank · Eye & Vision Consortium ... • Autorefraction & keratometry • Intraocular pressure • Corneal biomechanics On 87,642 people • Retinal

CHASE- St Georges/Kingston

QUARTZ

RETINAL

VASCULOMETRY

SYSTEM

Kingston

Sarah Barman

St Georges

Chris Owen

Alicja Rudnicka

Page 13: Eye & Vision Consortium - UK Biobank · Eye & Vision Consortium ... • Autorefraction & keratometry • Intraocular pressure • Corneal biomechanics On 87,642 people • Retinal

www.moorfields.nhs.uk

UK Biobank Baseline Eye Data

On 129,761 people • Visual Acuity

• Autorefraction & keratometry

• Intraocular pressure

• Corneal biomechanics

On 87,642 people • Retinal photographs & HD-OCT

UK Biobank - a new age for ophthalmic epidemiology

Page 14: Eye & Vision Consortium - UK Biobank · Eye & Vision Consortium ... • Autorefraction & keratometry • Intraocular pressure • Corneal biomechanics On 87,642 people • Retinal
Page 15: Eye & Vision Consortium - UK Biobank · Eye & Vision Consortium ... • Autorefraction & keratometry • Intraocular pressure • Corneal biomechanics On 87,642 people • Retinal

72 Consortium members 22 Health science centres across Scotland, Wales, Northern Ireland and England Bristol Cambridge Cardiff City, London Dundee Edinburgh Essex Gloucester NHS Kings, London Kingston Leeds Liverpool Manchester Moorfields NHS Newcastle Nottingham Queens, Belfast Southampton St Georges UCL – Institute of Ophthalmology UCL – Institute of Child Health UEA

http://www.ukbiobankeyeconsortium.org.uk/

Page 16: Eye & Vision Consortium - UK Biobank · Eye & Vision Consortium ... • Autorefraction & keratometry • Intraocular pressure • Corneal biomechanics On 87,642 people • Retinal

Funding

Moorfields Eye Hospital Special

Trustees

Research Groups

Page 17: Eye & Vision Consortium - UK Biobank · Eye & Vision Consortium ... • Autorefraction & keratometry • Intraocular pressure • Corneal biomechanics On 87,642 people • Retinal

http://www.ukbiobankeyeconsortium.org.uk/

Page 18: Eye & Vision Consortium - UK Biobank · Eye & Vision Consortium ... • Autorefraction & keratometry • Intraocular pressure • Corneal biomechanics On 87,642 people • Retinal
Page 19: Eye & Vision Consortium - UK Biobank · Eye & Vision Consortium ... • Autorefraction & keratometry • Intraocular pressure • Corneal biomechanics On 87,642 people • Retinal
Page 20: Eye & Vision Consortium - UK Biobank · Eye & Vision Consortium ... • Autorefraction & keratometry • Intraocular pressure • Corneal biomechanics On 87,642 people • Retinal

• One of the world’s largest ophthalmic datasets

• Large UK-based consortium facilitating

analysis of data

• Industry-academic collaboration has helped to

convert raw images into data

• Development of UKBB offers novel insights

into eye disease in the UK and worldwide

[email protected]