MODEL OVERVIEWThe extremely quiet FF and FFC ventilators are available from 50 to 3600 CFM, with static pressure capabilities to 1". All units have centrifugal blower wheels and low RPM motors on resilient mounts (except FF50 and AF80).

The forward curved centrifugal wheel with its high static pressure capability makes these ventilators suitable for either ducted or nonducted applications. They include removable blower assemblies and plug-in permanently lubricated motors for ease of servicing and cleaning.

Model FF

Model FFC

MODELS AF, FF & FFCCEILING AND INLINE/CABINET VENTILATORS

MODEL AF, FF FEATURES• Exhaust air up to 1500 CFM• Forward curve centrifugal wheel for high static pressure capabilities to 1”

w.g.• Resilient mount, low RPM motor for quiet operation (except FF50 and AF80)• Speed controllable• AMCA Seal for Air Performance• cULus Listed (except FF50 & AF80 which are UL only)

MODEL FFC FEATURES• Exhaust air up to 3600 CFM• Forward curve centrifugal wheel for high static pressure capabilities to 1” w.g.• Resilient mount, low RPM motor for quiet operation• Speed controllable• AMCA Seal for Air Performance• cULus Listed

Models FF and FFC are available in our Quickship program. All sizes are available for next day shipping from stock.

GC_FF-FFC_0

Page 4: Extractores Aire de Baño

35

CONSTRUCTION/SPECIFICATION CHECKLIST

Grille• Conceals interior.

• White polymeric (FF50 - FF300).

Blower• Low RPM for quiet operation, speed controllable.• Resilient anti-vibration mounts (FF50 & AF80 rigid mount).

FFC2000 & FFC3500).• Permanently lubricated, thermally protected motor.• Plug-in motor.• Designed for continuous operation.

Housing• Rugged, 20 gauge galvanized steel.• Duct connector.• 1/2" acoustic insulation inside (except FF50, AF80 & FFC's).• Integral automatic backdraft damper.• Easy inline conversion available (FF100-FF1500).• May be installed in ceiling or wall.• Mounting brackets for easy installation and adaptability to numerous mounting requirements.• Factory-shipped in horizontal discharge position, easily converted to vertical discharge.• FFC inline units have a removable panel which allows for easy motor access without

disturbing ductwork.

AMCA Seal• AMCA Air and Sound Licensed

UL Label• cULus listed (except FF50 & AF80 which are UL only).

MODELS FF & FFCCEILING AND INLINE/CABINET VENTILATORS

Page 5: Extractores Aire de Baño

36

OPTIONS/ACCESSORIES

Roof Cap and Wall Cap• Weather resistant duct termination.

Inline Adapter Kit• Converts FF units into inline units.• Available for FF100 through FF1500

Radiation Damper

• Mounts directly to the fan, screws provided.• Galvanized steel frame.

• 212oF fusible link.• Stainless steel negator-type closure spring.• Available for FF100 through FF1500.

Metal Grille Kit• White enamel painted steel.• Mounting screws included.

Duct Transition• Allows for quick transition to round ducting.• Galvanized steel construction.

Vibration Dampening Hangers• Rubber in shear.• Heavy-gauge steel construction with neoprene vibration dampening cushion.• For use with 3/8" threaded rod (by others).

Damper Kit (for FFC 2000 and FFC 3500)

• Foam cushion and magnetic catch assure quiet backdraft prevention.

MODELS FF & FFCCEILING AND INLINE/CABINET VENTILATORS

Page 6: Extractores Aire de Baño

37

OPTIONS/ACCESSORIES (cont.)

961L In-Line Adaptor Kit• Galvanized steel• Fits FF100 & FF150• For 6” round duct intake

982L In-Line Adaptor Kit• Galvanized steel• Fits FF400, FF500 & FF700• 4 1/2 x 18 1/2” duct intake

981L In-Line Adaptor Kit• Galvanized steel• Fits FF200, FF250 & FF300• For 8” round duct intake

983 In-Line Adaptor Kit• Galvanized steel• Fits FF900 & FF1500• 8” x 12” round duct intake

Model 441 Wall Cap• Gravity dampers• Collar with birdscreen for attaching 10”

round duct• Steel construction with aluminum louvers

Model 613 Wall Cap• High Capacity• Built-in backdraft damper & birdscreen

• For 12” round duct

Model 641 Wall Cap

• Built-in backdraft damper & birdscreen• For 6” round duct

Model 642 Wall Cap

• Built-in backdraft damper• For 3” or 4” round duct

(4” to 3” transition included)

Model 643 Wall Cap

• Built-in backdraft damper• For 8” round duct

Model 437 Roof Cap• High capacity design - up to 1200 CFM• Built-in spring-loaded backdraft damper &

birdscreen• Steel, black electrically - bonded epoxy

Model 636 Roof Cap

• Built-in backdraft damper & birdscreen• For 3” or 4” round duct

Model 636AL - Aluminum

Model 634 Roof Cap

• Built-in backdraft damper & birdscreen• For 3 1/4” x 10” or up to 8” round duct

Model 644 - Aluminum

MODELS FF & FFCCEILING AND INLINE/CABINET VENTILATORS

Page 7: Extractores Aire de Baño

38

OPTIONS/ACCESSORIES (cont.)

Size A B C D18 19 29.5 22 2720 21 29.5 22 30

Speed Control

• 5 amp & 10 amp - 120V• 6 amp - 240V• 6 amp - 277V

Model RCXIISF12 Flat Roof Cap

• Built-in birdscreen• For up to 12” round duct

Model RCXII08Curb Mount Roof Cap

• For curb mount installation• Use 14-3/4” x 14-3/4” x 8” high curb

• Built-in birdscreen• For up to 8” round duct

Model RCXIISF08 Flat Roof Cap

• Built-in birdscreen• For up to 8” round duct

Model RCXII12Curb Mount Roof Cap

• For curb mount installation• Use 22-1/4” x 22-1/4” x 8” high curb.

• Built-in birdscreen• For up to 12” round duct

Model MG 1 Metal Grille Kit • White enamel painted steel• Mounting screws included• Fits FF100, FF150, FF200, FF250 & FF300

Models 423 & T81212 Duct Transitions• Galvanized steel• Allows for quick transition to easy-to-obtain-and-install round ducting• 423 ( 4 1/2” x 18” to 10 round) for use with FF400 thru FF700• T81212 ( 8” x 12” to 12” round) for use with FF900 and FF1500

Models RD1, RD2 & RD3 Radiation Dampers

• Galvanized steel frame• High temperature, non-asbestos, reinforced fiber thermal fabric

• Stainless steel negator-type closure spring• RD1 (12 1/4’ x 12 1/4”) fits FF100 - FF300• RD2 (211/2” x 18”) fits FF400 - FF700• RD3 (22” x 18”) fits FF900 - FF1500

Model RCXII - 18” and 20” units

D

C

A

2”

B

14

12

9

2”

16.5

14

12

9

22

20

16

13

2”

24

20

16

13

24

MODELS FF & FFCCEILING AND INLINE/CABINET VENTILATORS

Model RD80AF Radiation Damper•

ceiling,roof-ceiling design• Galvanized steel frame• High temperature, non-asbestos, reinforced fiber

thermal fabric• • Stainless steel closure springs• RD80AF fits AF80

Page 8: Extractores Aire de Baño

CEILING MOUNT MODEL FF IN-LINE/CABINET MODEL FFCVARIABLE SPEED CONTROLS

FF50AF80

FF100FF150

FF200FF250FF300

FF400FF500 FF700 FF900 FF1500 FFC100

FFC150

FFC200FFC250FFC300

FFC400FFC500FFC700

FFC900 FFC1500 FFC2000 FFC3500

2727.1 (5 AMP 120V) X X X X X X2828.1 (10AMP 120V) X X X X X X X X X X X X

80L in-unit speed control (3 amp 120 Volt) Ships

mounting

X X X X X X X X X

75V (240V) X X X X X X277V (277V) X X X X X X

ROOF CAPS437 X X X

RCXII08, RCXIISF08 X X X X XRCXII12, RCXIISF12 X X X X X X X X

634M X X634,644 X X X X

636, 636AL XRCXII18 XRCXII20 X

WALL CAPS441 X X X613 X X X X641 X X642 X643 X X

IN-LINE ADAPTERS961L X981L X982L X X983L X X

UL RADIATION DAMPERSRD1 X XRD2 X XRD3 X X

RD for AF80 XMETAL Grille KIT

G102 XG103 XMG1 X X

DUCT TRANSITIONS423 X X X

T81212 X X X XDAMPER KITS

D101 XVIBRATION DAMPENING HANGERS (4)

V102 X* X X X X X X X X X XV104 X X X X X X X X X X X X X

OPTIONAL ACCESSORY COMPATIBILITY CHART

MODELS FF & FFCCEILING AND INLINE/CABINET VENTILATORS

* Compatible with AF80 but not FF50

Page 9: Extractores Aire de Baño

40

MODELFF

CFM / Sones at Static Pressure (PS - Inches of H2O) AMPS @ 60HZ/

WATTS

RPM @ 1/8 Voltage

Average Ship Wt.

Lbs0 1/10 1/8 1/4 3/8 1/2 5/8 3/4 7/8 1

5052 49 47 42 29 - - - - -

0.8/48 1870 120 43.9 4.3 4.4 4.6 5.5 - - - - -

100136 115 109 93 80 65 44 - - -

1.1/87 640 120 230.5 0.8 0.9 1.3 1.8 2.3 3.0 - - -

150181 161 157 141 132 124 114 94 62 -

1.3/100 710 120 231.3 1.4 1.5 2.2 2.6 3.1 3.6 4.1 4.6 -

200231 214 210 196 186 177 165 144 113 51

1.8/127 740 120 231.6 1.8 1.7 2.3 2.9 3.5 4.1 4.9 5.3 5.3

250272 261 259 250 242 233 218 201 165 99

2.1/166 830 120 232.1 2.3 2.2 2.9 3.3 3.9 4.4 4.8 5.5 5.8

300312 309 308 303 296 287 273 254 219 125

2.6/212 905 120 232.8 2.9 2.9 3.3 3.5 3.9 4.3 4.7 5.1 5.6

400480 442 434 388 344 299 229 182 114 -

1.4/146 735 120 342.0 2.4 2.3 2.8 3.3 3.8 4.5 4.8 5.4 -

500538 520 514 491 463 434 389 339 282 186

2.2/232 810 120 343.0 3.1 3.3 3.6 4.0 4.4 5.0 5.7 6.2 6.7

700722 704 701 667 640 607 571 534 453 333

2.9/313 960 120 344.5 4.6 4.7 4.8 5.0 5.2 5.6 6.2 7.1 7.2

900918 905 901 877 842 793 725 636 536 390

3.0/306 650 120 643.8 4.0 4.1 4.0 4.2 4.3 4.4 4.9 4.5 5.3

R

®

AIR

MOVEMENT

AND CONTROL

ASSOCIATION

INTERNATIONAL, INC.

AIRPERFORMANCE

SOUNDand

S&P USA Ventilation Systems, LLC., Div. that the

Models FF shown herein are licensed to bear the AMCA Seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirement of the

MODEL FF PERFORMANCE

FF CEILING VENTILATORS

MODELS FF & FFCCEILING AND INLINE/CABINET VENTILATORS

15001578 1526 1513 1438 1371 1285 1198 1103 1000 816

5.0/468 955 120 648.6 8.4 8.4 8.1 7.5 7.0 6.7 6.2 5.8 5.8

MODEL AF80AMPS @

60HZ/WATTS

CFM / Sones at Static Pressure (in wc)Volts Nominal

(RPM) Duct SizeAverage Ship Wt.

(lbs)0.0 0.1 0.15 0.2 0.25 0.3 0.35 0.4

0.3/2789 79 72 65 58 51 44 36

120 1,110 4” Round 80.6 0.9 - - 2.1 - - -

MODEL AF80AMPS @

60HZ/WATTSCFM / Sones at Static Pressure (in wc)

0.1 0.25

0.3/2780 60

1.5 -

Page 10: Extractores Aire de Baño

MODEL FFC PERFORMANCE

FFC INLINE/CABINET VENTILATORS

FFC CABINET VENTILATORS

MODELFFC

CFM / Sones at Static Pressure (PS - Inches of H2O) AMPS @

60HZ/ WATTS

RPM @1/8 Voltage

Average Ship Wt.

Lbs.0 1/10 1/8 1/4 3/8 1/2 5/8 3/4 7/8 1

100121 108 106 97 93 86 70 44 - -

1.0/87 760 120 230.5 0.7 0.7 1.1 1.4 1.8 2.1 2.4 - -

150153 148 147 140 134 125 111 91 54 -

1.3/100 920 120 230.9 1.0 1.1 1.4 1.6 1.9 2.1 2.2 2.4 -

200205 196 195 190 185 175 158 135 96 47

1.8/127 865 120 231.7 1.9 1.9 2.1 2.3 2.4 3.0 3.3 3.4 3.4

250248 245 245 241 235 224 208 183 141 84

2.1/166 1005 120 232.0 2.3 2.3 2.8 2.8 3.2 3.4 3.6 3.9 3.8

300300 294 293 285 274 259 243 214 168 113

2.6/212 1145 120 232.9 3.0 3.1 3.3 3.4 3.5 3.6 3.7 4.0 3.9

400450 415 406 360 313 271 223 167 90 6.0

1.4/146 775 120 341.4 1.6 1.6 1.9 2.2 2.6 2.9 3.4 3.6 3.9

500546 526 519 496 472 447 407 364 306 232

2.2/232 890 120 342.4 2.4 3.4 3.7 3.9 3.8 3.9 4.0 4.3 4.3

700704 686 681 656 631 604 575 533 480 412

2.9/313 1090 120 343.6 3.8 3.7 3.9 4.0 4.2 4.3 4.4 4.7 5.0

900930 902 894 853 807 754 685 587 442 300

3.0/306 810 120 643.7 3.8 3.8 3.8 3.7 3.8 3.9 4.0 4.0 4.1

15001275 1228 1214 1152 1092 1029 958 871 764 631

5.0/468 1055 120 646.8 6.8 6.7 6.5 6.3 6.0 6.0 6.0 6.0 6.1

MODELFFC

CFM / Sones at Static Pressure (PS - Inches of H2O) AMPS @ 60HZ/

WATTS

RPM @1/8 Voltage

Average Ship Wt.

Lbs.0 1/10 1/8 1/4 3/8 1/2 5/8 3/4 7/8 1

20001891 1803 1791 1657 1508 1347 1165 808 - -

5.8/590 965 120 9210.3 9.8 9.4 9.0 8.6 9.1 8.9 7.0 - -

35003605 3498 3452 3278 3073 2983 2679 2429 2093 1693

5.4/1205 1105 240 13915.3 14.8 14.5 14.1 13.1 12.8 12.1 11.8 11.9 10.8

-

R

®

AIR

MOVEMENT

AND CONTROL

ASSOCIATION

INTERNATIONAL, INC.

AIRPERFORMANCE

SOUNDand

S&P USA Ventilation Systems, LLC., Div. of Soler & Palau Ventilation Group,

herein are licensed to bear the AMCA Seal. The ratings shown are based on test and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the

Ratings Program.

MODELS FF & FFCCEILING AND INLINE/CABINET VENTILATORS

Page 11: Extractores Aire de Baño

42

DIMENSIONS

INLINE/CABINET VENTILATOR

CEILING VENTILATORFF50

MODELS FF & FFCCEILING AND INLINE/CABINET VENTILATORS

AF80

Page 12: Extractores Aire de Baño

FF CEILING VENTILATORS QUICK SELECTION GUIDEFF50 AF80

FF100, FF150FF200, FF250,

FF300

FF400, FF500,FF700 FF900, FF1500

MODELS FF & FFCCEILING AND INLINE/CABINET VENTILATORS

Page 13: Extractores Aire de Baño

FF & FFC QUICK SELECTION GUIDELINES1. Locate desired CFM on bottom horizontal axis of graph.

2. Locate system static pressure on left vertical axis of graph.

3. Determine intersection of CFM and static pressure.

4. Select fan curve to the right of this intersection.

5. Solid state speed control may be used for selections left of

FFC INLINE/CABINET VENTILATORS QUICK SELECTION GUIDE

FFC100, FFC150FFC200, FFC250,

FFC300

FFC400, FFC500,FFC700 FFC900, FFC1500

FFC2000, FFC3500

round duct transition.

(accessories).

MODELS FF & FFCCEILING AND INLINE/CABINET VENTILATORS

Page 14: Extractores Aire de Baño
Page 15: Extractores Aire de Baño

NEW SPECIF ICATIONS

REPLACING SPECIF ICATIONS

New Model

CFM SonesReplacing Model

CFM Sones

PC80XP 90 0.4 PC80X 90 0.5PC110XP 120 0.3 PC110X 130 0.9PC150XP 150 0.5 PC150 150 1.1

The new Premium CHOICE XP series is built for today’s demanding requirements featuring seamless Plug-&-Play integration and a redesigned blower for a quiet, energy efficient performance.

MODEL FEATURES• Extremely Energy Efficient• Higher Air Flow• Up to 70% Quieter*• Increased static pressure capability

N E W

XP Series

Check out our other Premium CHOICE series models

AC Motor Models

DC Motor Models

Value Models

Low Profile Models

Recessed Vent LightModels

*Please visit solerpalau-USA.com for exact model specifications

Page 16: Extractores Aire de Baño

PC AC Motor Models

PCDDC Motor Models

PCRLRecessed Vent Light Models

PCVValue Series Models

PCLPLow Profile Models

Page 17: Extractores Aire de Baño

Bathroom Fan Sizing

Based on the Home Ventilating Institute (HVI) guidelines:

FAN SIZING FOR BATHROOMS UNDER 100 SQUARE FEET

FAN SIZING FOR BATHROOMS OVER 100 SQUARE FEET

The standard rule for bathrooms 100 square feet or smaller is one CFM per square foot of the bathroom. To find the square footage, multiply the length of the bathroom by the width.

9’

5’45 sq.ft.

The minimum recommendation is a fan rated at least 45 CFM.

Ventilation for baths over 100 square feet is calculated based on the fixtures in the bathroom (see table below). Add the CFM of all fixtures within the bathroom for the required fan CFM.

CFM REQUIRED PER FIXTUREToilet 50 CFMShower 50 CFMBath Tub 50 CFMJetted Tub 100 CFM

Note: Enclosed toilet rooms must have an operable window or a fan for ventilation.

EXAMPLE1 Toilet 50 CFM1 Shower 50 CFM1 Jetted Tub 100 CFMCFMRequirements

200 CFM

Two Solution Options:1. Install a 100 CFM fan over the tub, 50CFM fan in the shower and above the toliet. This method will

provide ventilation where and when it’s needed.2. Install one 200 CFM fan. The air will be pulled through the entire room and exhausted at a central

location.

For more information on bath fan sizing and ventilation, visit www.hvi.org.

Page 18: Extractores Aire de Baño

LONG LIFEPermanently lubricated motors are engineered for trouble-free continuous operations for 30,000 hours on AC motors and 60,000 hours on DC motors. PC fans feature robust steel housings and attractive, sturdy grilles making the Premium CHOICE Series a fan you can fit and forget.

ENERGY EFFICIENTSelect Premium CHOICE fans feature the ENERGY STAR qualification. These PC fans come standard with high efficiency motors and lighting to reduce energy consumption without sacrificing performance. Look for this logo for the most energy efficient choice.

EASE OF INSTALL ATIONPremium CHOICE Series fans are designed for easy installation for both new construction and retrofit installation. All models come with adjustable hanger bars, unique wiring design allowing for in-room or outside wiring, and dust-guard packaging to prevent over-spray of paint or ceiling materials when units are installed in new construction applications.

PLUG&PL AY DESIGNS&P’s Premium CHOICE fans feature the ultimate flexibility when it comes to your bathroom fan experience. With plug-in features such as humidity and motion sensors, to grilles to fit every aesthetic, there’s something for everyone. Simple “Plug-&-Play” design makes installation a snap.

IAQ SenseIAQ Sense makes Premium CHOICE fans the most intelligent fan on the market. This sensor plugs into standard PC fans and automatically detects VOCs and humidity within a room, running when and where its needed. Learn more on page 7.

LONGEST WARR ANT YS&P’s Premium CHOICE fans come standard with the industry’s longest warranty. AC models include a 5-year warranty, while DC models have a 6-year warranty.

The PC Difference

IAQ Sense

AWARDWINNER

Page 19: Extractores Aire de Baño

S&P’s unique Plug-&-Play options make your CHOICE easy. Whether you’re looking for a Speed Control, Humidity Sensor, Motion Sensor or VOC Sensor, there is a control that connects to the receptacle and easily mounts into the pre-drilled holes inside the fan housing.

There is a receptacle for your grille CHOICE. Need a lighted fan? Choose the fluorescent or LED Lighted Grille Kits. Need a motion sensing fan? Choose the Motion Sensing Grille Kit. Either grille easily plugs into the grille receptacle to give you the fan of your CHOICE!

PC Fan models include receptacles based on compatibility. Learn more in our Accessories section.

S&P Premium CHOICE fans feature Intergral Vibration Isolators standard on select styles*.

Integral Vibration Isolators

* Not standard in PCV50, or PCLP fans. Available as an optional accessory

PC Fan Features

Plug-&-Play Modules and Grilles

Integral Vibration Isolators

Grille ReceptacleMotor Receptacle

Humidity Sensor, Speed Control,

Motion Sensor or Bluetooth® Speaker Module Receptacle

PCIAQS (VOC/Humidity Sensor) Module Receptacle*

*The receptacle for the PCIAQS is field installed.

Page 20: Extractores Aire de Baño

7

IAQ SENSE DETECTS & EXTR ACTS:

• Humidity• Carbon Monoxide (CO)• Carbon Dioxide (CO2)• Ammonia• Acetone• Benzene• Ethylene glycol• Formaldehyde• Methylene chloride• other harmful VOCs

As buildings are being built with higher quality construction methods, balanced ventilation methods are more important than ever. An unbalanced home results in poor Indoor Air Quality (IAQ), causing inadequate conditions for your home and the inhabitants. As codes change, it is important for you to understand why Indoor Air Quality is so important and the options available to you from S&P USA.

IAQ Sense : A FAN THAT THINKS!IAQ Sense makes Premium CHOICE fans the most intelligent fan on the market. The IAQ SENSE sensor plugs into a standard PC fans and automatically detects VOCs and humidity within a room, running when and where its needed.Simply set up the sensor to your preferred concentration of particles (PPM) , and forget it. When the PPM is reached or a rapid increase of moisture is detected, the fan will turn on to a high speed to quickly exhaust the room; once a certain time has been reached, the fan will adjust to run at a low speed. The IAQ sensor includes a speed control to adjust the fan at a percentage of full speed so the fan can be run continuously to meet code requirements. A PC fan with a PCIAQS is a fan you can trust to keep you, your family, and your home safe.

Advancing Ventilation™

IAQ Sense Plug-in

IAQ Sense

AWARDWINNER

T h e E P A r a n k sI N D O O R A I R P O L L U T A N T S

as a

T O PF I V E

Page 21: Extractores Aire de Baño

FEATURES • Extremely quiet operationMODELS• PC50X

AC Standard Models

MODULE + GRILLE COMPATIBILIT Yfor PC50X

FEATURES • Extremely quiet operation 0.3 to 1.1 sones• Redesigned blower• Seamless Plug-&-Play intergrationCOMING SOON: Contractor Packs for PC80XP + PC110XP (pack of 4)

MODELS• PC80XP• PC110XP• PC150XP• PCXP 230V

Premium CHOICE XP Series

MODULE + GRILLE COMPATIBILIT Yfor PC110XP + PCXP 230V

The new Premium CHOICE XP ser ies i s bu i l t for today ’s demanding requi rements fea tur ing seamless P lug-&-P lay in tegra t ion and a redes igned b lower for a qu ie t , energy e f f ic ien t per formance.

Module/Grille PC80XP PC110XP PC150XP PCXP 230V

PCLKP -

PCLEDKP -

PCHSP -

PCSCP

PCIAQSP -

PCMGP

PCMHKP

PCLMHKP -

*

* UL certified includes 230V ONLY

Module/Grille PC50X

PCLK -

PCLEDK -

PCLMK -

PCMK -

PCVLK

PCVLEDK

PCHS

PCBTS -

PCSC

PCIAQS -

PCMG -

Page 22: Extractores Aire de Baño

9

MODULE + GRILLE COMPATIBILIT Y

DC Motor Models

FEATURES• Extremely quiet operation 0.3 to 2.5 sones• Brushless DC motor for long life• High/Low speed delay timer

(Excluding PCD200)

Model Built-in Control GrillePCD80XH Humidity Sensor Standard

PCD110X - Standard

PCD110XH Humidity Sensor Standard

PCD110XM - Motion Sensing

PCD110XMH Humidity Sensor Motion Sensing

PCD110XIAQS IAQ Sense Standard

PCD200 - Standard

MODELS

MODULE + GRILLE COMPATIBILIT YPCD80XH PCD110X PCD110XH PCD110XM PCD110XMH PCD110XIAQS PCD200

PCLK - - - -

PCLEDK - - - -

PCDLMG - - - - -

PCMG - - - - -

PCRD - - - -

PCVLK - - - - - -

PCVLEDK - - - - - -

PCVRD - - - - - -

PCVLEDKRD - - - - - -

PCHS - - - - - -

FEATURES• Low profile housing design• Suitable for sidewall mounting• Quiet operation 1.2 to 2.0 sones• Available as Contractor Packs (Pack of

4)

OP TIONAL ACCESSORYPCLPR4-3 4” Oval to 3” Round ReducerThe PCLPR4-3 is a 4” oval to 3” round duct reducer that can be used to quickly and easily connect 3” round duct to the PCLP80 and 100. This is a common duct size used with low profile bathroom exhaust fans installed in 2x4 walls.

Low Profile Models

PCLP80 PCLP100PCLPLEDK

PCLPHS

PCLPSC

PCLPR4-3

Page 23: Extractores Aire de Baño

Value Series Models

MODULE + GRILLE COMPATIBILIT Y

MODULE + GRILLE COMPATIBILIT Y

Module/Grille PCV50 PCV80

PCVLK

PCVLEDK

PCHS

PCSC -

FEATURES • Quiet operation 1.5 to 2.5 sones• 4” duct connector with built-in backdraft

damper

MODELS • PCV50• PCV80 (ENERGY STAR® Certified)

FEATURES • Designed to look like a recessed can light• Quiet operation 1.2 sones

Recessed Vent Light

Module/Grille PCRL80 PCRL80F

PCRL80LC IncludedPCHS

PCSC

Page 24: Extractores Aire de Baño

CFL Lighted Grille Kit-PCLK/PCLKP• 13 watt GU24 bulb• 2700K/900 lumens• 4 watt night light bulb• Can be installed with new or pre-installed fan

LED Lighted Grille Kit-PCLEDK/PCLEDKP• 11 watt LED light• 4100K/1100 lumens• 2 watt LED night light setting 200 lumens• Can be installed with new or pre-installed fan

CFL Lighted Grille Kit-PCVLK• 113 watt GU24 bulb• 2700K/900 lumens• Simple plug-in receptacle in fan housing• Can be installed with new or pre-installed fan

LED Lighted Grille Kit-PCVLEDK• 11 watt LED light• 4100K/1100 lumens• 2 watt LED night light setting 200 lumens• Can be installed with new or pre-installed fan

LED Lighted Grille Kit for PCLP-PCLPLEDK• 11 watt LED light• 4100K/1100 lumens• 2 watt LED night light setting 200 lumens• Can be installed with new or pre-installed fan

Motion Sensing Grille Kit- PCMK• Adjustable high speed run time delay from 3 to

30 minutes• Continuous low speed operation (adjustable

from 30-100% of high speed) when motion isnot detected

• Automatic boost to high speed operation whenmotion is detected

Motion Sensing Lighted Grille Kit- PCLMK• 13 watt GU24 bulb• 2700K/900 lumens• 4 watt night light bulb• Automatically turns on fan when motion is

sensed• Adjustable time delay shut-off from 3 to 30

minutes• Adjustable speed reduced up to 50%

Motion and Humidity Sensing Grille Kit -PCMHK/PCMHKP• Automatically turns on fan when motion or

humidity is sensed• Adjustable time delay shut-off from 3 to 30

minutes• Adjustable speed reduced up to 50%

Motion and Humidity Sensing Lighted Grille Kit-PCLMHK/PCMHKP• 13 watt GU24 bulb• 2700K/900 lumens• 4 watt night light bulb• Automatically turns on fan when motion

and/or humidity is sensed• Adjustable time delay shut-off from 3 to 30

minutes• Adjustable speed reduced up to 50%

METAL GRILLEMetal Grille - PCMG/PCMGP• 13 x 14” Metal Grille• Ideal for commercial

applications

Plug-&-Play Grilles

LIGHTED GRILLE KIT

SENSING GRILLE KIT

LIGHTED GRILLE KIT

Page 25: Extractores Aire de Baño

Humidity Sensor - PCHS/PCHSP• Detects rapid rise in humidity• Auto-shut off timer• Accessible sensitivity adjustment• Meets CALGreen bathroom fan requirement• Simple plug-in receptacle in fan housing• Can be installed with new or pre-installed fan

Speed Control - PCSC/PCSCP• Accessible speed adjustment• High speed override• Allows for adjustable continuous speed to meet

ASHRAE 62.2• Simple plug-in receptacle in fan housing• Can be installed with new or pre-installed fan

Bluetooth® Speaker - PCBTS • High quality Bluetooth® wireless speaker• Easy pairing with most Bluetooth® - enabled

devices• After inital pairing, connection to device is

automatic• 30 foot Bluetooth® range• Simple plug-in receptacle in fan housing• Can be installed with new or pre-installed

fan

3- Switch Control-PC3S• Three Rocker Combination Switch with ground

screw terminals and push-in wiring

Fan/Light Delay Timer Switch-FLTD-60• One Switch controls fan and light• Digital Timing circuit• Saves energy by automatically turning

exhaust fan off• Fits single switch outlet box

Rotary Spring Wound Timer-SRT-30• Hold feature enables user to override the

automatic shut-off function• Time saving up front terminal connection with

teeter-type terminals• Press-on knob design ensures quick and easy

installation• CFL Compatible

Electronic Push Button Timer-EPBT-60• 10-20-30-60 minute timer• Activate by pushing the button

ASHRAE 62.2 Bath Fan Ventilation Control - FT622• Programmable DELAY and VENTILATION

settings• Works with ALL incandescent, CFL, fluorescent

and LED lights up to 450 watts• Earn LEED and ENERGY STAR points for

enhanced exhaust ventilation

Programmable Fan Timer 24 Hours/ 7 Days - FT247• Provides 7 ON and 7 OFF events per day• LCD display• Rechargeable battery back-up• Push button activation• Note: Do not use with fluorescent lamp

ballastsE

IAQ Sense, VOC/Humidity Sensor PCIAQS/PCIAQSP• Detects VOCs and/or rapid rise in humidity• Semiconductor gas sensor, detecting a wide

range of VOCs• Monitoring range is 400-2000 ppm equivalent

CO2• Continuous speed control to run fan

continuously• Integrated control switch to turn features on/off• Field adjustable humidity sensitivity with 50-

100% range. Factory setting is 75%• Humidity is sensed at the ceiling• Simple plug-in receptacle in fan housing• Can be installed with new or pre-installed fan• Meets CALGreen bathroom fan requirement

Humidity Sensor - PCLPHS• Detects rapid rise in humidity• Auto-shut off timer• Accessible sensitivity adjustment• Meets CALGreen bathroom fan requirement• Simple plug-in receptacle in fan housing• Can be installed with new or pre-installed fan

Speed Control - PCLPSC• Accessible speed adjustment• High speed override• Allows for adjustable continuous speed to meet

ASHRAE 62.2• Simple plug-in receptacle in fan housing• Can be installed with new or pre-installed fan

Plug-&-Play Modules

Wall Control Options

PCHSP

PCHS

PCSC

PCSCP

PCBTS

Page 26: Extractores Aire de Baño

COMPATIBILITY

Module/Grille PC50X

PCLK -

PCLEDK -

PCLMK -

PCMK -

PCVLK

PCVLEDK

PCHS

PCBTS -

PCSC

PCIAQS -

PCMG -

P C COMPATIBILIT Yfor PC50X for XP Ser ies

Module/Grille PC80XP PC110XP PC150XP PCXP 230V

PCLKP -

PCLEDKP -

PCHSP -

PCSCP

PCIAQSP -

PCMGP

PCMHKP

PCLMHKP -

P CD COMPATIBILIT YMODULE/GRILLE PCD80XH PCD110X PCD110XH PCD110XM PCD110XMH PCD110XIAQS PCD200

PCLK - - - -

PCLEDK - - - -

PCDLMG - - - - -

PCMG - - - - -

PCVLK - - - - - -

PCVLEDK - - - - - -

PCVRD - - - - - -

PCHS - - - - - -

P CLP COMPATIBILIT YMODULE/GRILLE PCLP80 PCLP100

PCLPLEDK

PCLPHS

PCLPSC

P CV COMPATIBILIT YMODULE/GRILLE PCV50 PCV80

PCVLK

PCVLEDK

PCHS

PCSC -

PCVRD

PCVLEDKRD

P CRL COMPATIBILIT YMODULE/GRILLE PCRL80 PCRL80F

PCRL80LC Included

PCHS

PCSC

Page 27: Extractores Aire de Baño

14

Radiation Damper (PCRD, PCRD-P2,PCLPRD, & PCVRD)• 3-hour rating ceiling radiation dampers• Ceramic fiber with fiberglass cover fire blanket• Roll-formed frame 22 g. galvanized steel• PCRD-P2 is an extended radiation damper to allow lighted grille fit• cETLus Listed

Radiation Dampers & Kits

MODULE/GRILLE

PCLK

RD

PCLK

RDP

PCLE

DKR

D

PCLE

DKR

DP

PCM

KRD

PCLM

KRD

PCM

HKR

D

PCM

HKR

DP

PCLM

HKR

D

PCLM

HKR

DP

PCM

GKR

D

PCM

GKR

DP

PCVL

EDKR

D

PCD

110M

RD

PCD

LMG

RD

PCRD

PCVR

D

PCLP

RD

PCLP

LED

KRD

PC50X - - - - - - - - - - - - - - - - -

PC150XP - - - - - - - - - - - - -

PC80XP - - - - - - - - - - - - -

PC110XP - - - - - - - - - - - - -

PCD80XH - - - - - - - - - - - - - - - - - - -

PCD110X - - - - - - - - - - - - - - -

PCD110XH - - - - - - - - - - - - - - -

PCD110XM - - - - - - - - - - - - - - - - -

PCD110XMH - - - - - - - - - - - - - - - - -

PCD110XIAQS - - - - - - - - - - - - - - -

PCD200 - - - - - - - - - - - - - - - - - - -

PCLP80 - - - - - - - - - - - - - - - - -

PCLP100 - - - - - - - - - - - - - - - - -

PCV50 - - - - - - - - - - - - - - - - -

PCV80 - - - - - - - - - - - - - - - - -

PCRL80 - - - - - - - - - - - - - - - - - - -

PCRL80F - - - - - - - - - - - - - - - - - - -

RD COMPATIBILIT Y

Radiation Damper Kit Radiation Damper Grille

PCLKRD PCRD-P2 PCLK

PCLKRDP PCRD-P2P PCLKP

PCLEDKRD PCRD-P2 PCLEDK

PCLEDKRDP PCRD-P2P PCLEDKP

PCMKRD PCRD-P2 PCMK

PCLMKRD PCRD-P2 PCLMK

PCMHKRD PCRD-P2 PCMHK

PCMHKRDP PCRD-P2P PCMHKP

PCLMHKRD PCRD-P2 PCLMHK

PCLMHKRDP PCRD-P2P PCLMHKP

PCMGKRD PCRD PCMG

PCMGKRDP PCRD PCMGP

PCVLEDKRD PCVRD PCVLEDK

PCD110MRD PCRD-P2 PCMRG

PCDLMGRD PCRD-P2 PCDLMG

PCLPLEDKRD PCLPRD PCLPLEDK

NEW

NEW

NEW

NEW

NEW

NEW

Page 28: Extractores Aire de Baño

Std.

Gril

le

PCLK

PCLK

P

PCLE

DK

PCLE

DKP

PCVL

K

PCVL

EDK

PCM

K

PCLM

K

PCM

HK

PCM

HKP

PCLM

HK

PCLM

HKP

PCBT

S

PCH

S

PCH

SP

PCSC

PCSC

P

PCIA

QS

PCIA

QSP

PCM

G

PCM

GP

PCLP

SC

PCLP

HS

PCLP

LED

K

PCLP

R4-3

PCLP

RD

Std. Grille - - - - - - - - - - - - - - - - - - - -

PCLK - - - - - - - - - - - - - - - - - - - - - - -

PCLKP - - - - - - - - - - - - - - - - - - - - - - - -

PCLEDK - - - - - - - - - - - - - - - - - - - - - - -

PCLEDKP - - - - - - - - - - - - - - - - - - - - - - - -

PCVLK - - - - - - - - - - - - - - - - - - - - - - - -

PCVLEDK - - - - - - - - - - - - - - - - - - - - - - - -

PCMK - - - - - - - - - - - - - - - - - - - - - - - - - - -

PCLMK - - - - - - - - - - - - - - - - - - - - - - - - - - -

PCMHK - - - - - - - - - - - - - - - - - - - - - - - - - - -

PCMHKP - - - - - - - - - - - - - - - - - - - - - - - - - - -

PCLMHK - - - - - - - - - - - - - - - - - - - - - - - - - - -

PCLMHKP - - - - - - - - - - - - - - - - - - - - - - - - - - -

PCBTS - - - - - - - - - - - - - - - - - - - - - - -

PCMG - - - - - - - - - - - - - - - - - - - - - - -

PCMGP - - - - - - - - - - - - - - - - - - - - - - - -

PCHS - - - - - - - - - - - - - - - - - - - - -

PCHSP - - - - - - - - - - - - - - - - - - - - - - -

PCSC - - - - - - - - - - - - - - - - - - - - -

PCSCP - - - - - - - - - - - - - - - - - - - - - - -

PCIAQS - - - - - - - - - - - - - - - - - - - - - - -

PCIAQSP - - - - - - - - - - - - - - - - - - - - - - -

PCRD - - - - - - - - - - - - -

PCVRD - - - - - - - - - - - - - - - - - - - - - -

PCLPSC - - - - - - - - - - - - - - - - - - - - - - - - -

PCLPHS - - - - - - - - - - - - - - - - - - - - - - - - -

PCLPLEDK - - - - - - - - - - - - - - - - - - - - -

PCLPR4-3 - - - - - - - - - - - - - - - - - - - - - -

PCLPRD - - - - - - - - - - - - - - - - - - - - -

The chart below indicates which plug-&-play grilles and modules can be used together. MODULE + GRILLE COMPATIBILIT Y