MECHANICAL/ELECTRICAL ENGINEER:
ARCHITECTURAL ENGINEERING CONSULTANTS
40801 US HIGHWAY 6 & 24, SUITE 214
EAGLE-VAIL, CO 81620
P.O. BOX 8489
AVON, CO 81620
Tel. 970 748-8520 Fax 970 748-8521
MECHANICAL CONTACT - DAVID DENIO
E-mail: [email protected]
ELECTRICAL CONTACT - CHUCK LANGSTON
E-mail: [email protected]
EAGLE COUNTY REGIONAL AIRPORT Administration Office Remodel
219 ELDON WILSON ROAD, GYPSUM
INDEX TO DRAWINGS
PROJECT DESCRIPTION PROJECT TEAM CODE ANALYSIS
OCCUPANCY
MAX. ALLOWABLE HEIGHT 65'-0"
CONSTRUCTION TYPE
FIRE SPRINKLERS
± 6,540' ABOVE SEA LEVELSITE ELEVATION
ZONE DISTRICT EAGLE COUNTY REGIONAL AIRPORT PUD
NO. OF STORIES TWO
VICINITY MAP
OWNER:
EAGLE COUNTY
P.O. BOX 850
EAGLE, CO 81631-0850
ARCHITECT:
MENENDEZ ARCHITECTS, P.C.
715 W.MAIN ST., SUITE 104
ASPEN, CO 81611
Tel. 970 544-4851 Fax 970 544-1915
E-mail: [email protected]
CONTACT: LUIS MENENDEZ
A-1
A-2
A-3
A-4
A-5
A-6
S1.1
S2.1
S3.1
M1.0
M2.0
E1.0
E1.1
E2.0
E3.0
TITLE SHEET
EXISTING & PROPOSED FLOOR PLANS
EXISTING RC PLAN & PROPOSED RC
PLAN
WALL SECTION, DETAILS
ASSEMBLIES, DETAILS
SCHEDULES, INTERIOR ELEVATIONS
GENERAL NOTES, SHEET INDEX,
KEYPLAN AND LEGEND
PARTIAL ROOF AND FLOOR FRAMING
PLAN
FRAMING AND FOUNDATION DETAILS
SPECS, SCHEDULES & SEQUENCE
HVAC PLAN
ELECTRICAL LEGEND, SPECS, AND
DETAILS
ELECTRICAL ONE-LINE & PANEL
SCHEDULES
POWER & SYSTEMS PLAN
LIGHTING AND RCP PLAN
SETBACKS 50' FROM COOLEY MESA ROAD,
F.A.A. REGULATIONS FROM CENTER-LINE OF RUNWAY
ALL WORK SHALL BE EXECUTED IN CONFORMANCE WITH THE 2003 INTERNATIONAL BUILDING CODE AND WITH ALL OTHER RULES,
REGULATIONS AND ORDINANCES GOVERNING THE PLACE OF BUILDING. CONTRACTOR SHALL BRING TO THE ATTENTION OF THE ARCHITECT
ANY CONFLICTS BETWEEN THE REQUIREMENTS OF THE BUILDING CODE AND THE DRAWINGS.
ALL WORK SHALL BE PERFORMED TO THE HIGHEST STANDARDS OF CRAFTSMANSHIP BY JOURNEYMEN OF THE APPROPRIATE TRADES.
ALL DIMENSIONS NOTED TAKE PRECEDENCE OVER SCALE. DIMENSIONS NOTED WITH "N.T.S." DENOTES NOT TO SCALE.
CONTRACTOR IS HEREBY NOTIFIED ASSUMPTIONS HAVE BEEN MADE ABOUT THE CONSTRUCTION METHODS, SYSTEMS AND MATERIALS
ORIGINALLY USED IN THE BUIILDING. THE CONTRACTOR, IN THE COURSE OF PERFORMING INVASIVE TESTING DURING CONSTRUCTION, SHALL
VERIFY THE ACCURACY OF THE ASSUMPTIONS AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.
CONTRACTOR SHALL VERIFY THE DIMENSIONS AND CONDITIONS OF ALL AFFECTED AREAS OF EXISTING STRUCTURE/SITE AND SHALL
REPORT TO THE ARCHITECT, IN WRITING, ANY DISCREPANCIES BETWEEN ACTUAL EXISTING CONDITIONS AND THE DRAWINGS.
CONTRACTOR SHALL TAKE REASONABLE MEASURES TO LOCATE AND MARK ALL UNDERGROUND UTILITIES IN AREAS SUBJECT TO
EXCAVATION, TRENCHING OR BORING PRIOR TO COMMENCING WORK.
ARCHITECT IS NOT RESPONSIBLE IN ANY WAY FOR THE MEANS, METHODS, SEQUENCE, PROCEDURES, TECHNIQUES OR SCHEDULING OF
CONSTRUCTION OR FOR JOB SAFETY. THESE DUTIES ARE THE RESPONSIBILITY OF THE CONTRACTOR.
ALL BUILDING COMPONENTS SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS.
CONTRACTOR SHALL iNSTRUCT EACH OF THE SUBCONTRACTORS TO BECOME THOROUGHLY FAMILIAR WITH ALL OF THE DRAWINGS.
WHEREVER EXISTING CONDITIONS MAY HAVE A BEARING ON THE EXPEDITIOUS PERFORMANCE OF THE WORK, THE SUBCONTRACTOR SHALL
VISIT THE JOB SITE AND PERSONALLY INSPECT AND VERIFY THE SITE FOR COMPARISON WITH THE DRAWINGS.
CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, FOR ARCHITECT APPROVAL, FOR THE FOLLOWING ITEMS PRIOR TO PERFORMANCE OF THE
WORK:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
GENERAL NOTES
STRUCTURAL ENGINEER:
GLENWOOD STRUCTURAL AND CIVIL, INC.
812 PITKIN AVENUE
GLENWOOD SPRINGS, CO 81601
Tel. 970 928-0135 Fax 970 928-9804
E-mail: [email protected]
CONTACT: ADOLFO GORRA
OWNER'S REPRESENTATIVE:
EAGLE COUNTY
PROJECT MANAGEMENT DEPARTMENT
P.O. BOX 850
590 BROADWAY
EAGLE, CO 81631-0850
Tel. 970 328-8780
E-mail: [email protected]
CONTACT: MR. RICK ULLOM
AUTOMATIC FIRE SPRINKLER SYSTEM NOTES
INTERIOR REMODEL OF EXISTING AIRPORT ADMINISTRATION OFFICES.
1.
1
2
3
4
5
6
7
8
9
10
11
REMOVE DESIGNATED PARTITIONS, COMPONENTS, BUILDING EQUIPMENT
AND FIXTURES.
CONFORM TO ALL APPLICABLE CODES RELATING TO DEMOLITION AND
HAZARDOUS MATERIALS.
ERECT AND MAINTAIN TEMPORARY BARRIERS AND SECURITY DEVICES.
ERECT AND MAINAIN TEMPORARY PARTITIONS TO PREVENT SPREAD OF
DUST.
PREVENT MOVEMENT OF STRUCTURE. PROVIDE BRACING AND SHORING
AND DESIGN OF SAME BY QUALIFIED PROFESSIONAL.
PROTECT EXISTING STRUCTURE, FINISHES, EQUIPMENT, ETC. WHICH ARE
NOT TO BE DEMOLISHED.
DEMOLISH AND REMOVE COMPONENTS IN AN ORDERLY AND CAREFUL
MANNER.
DISCONNECT AND CAP/ABANDON UTILITIES AS NECESSARY.
REMOVE DEMOLISHED MATERIALS FROM SITE AS WORK PROGRESSES
AND DISPOSE IN AN APPROVED AND LEGAL MANNER.
LEAVE AREAS OF WORK IN CLEAN CONDITION.
MAINTAIN EGRESS AND ACCESS AT ALL TIMES.
DEMOLITION NOTES
BUILDING IS FIRE SPRINKLERED; MODIFY SYSTEM IN SUBJECT SPACES, PER CODE REQUIREMENTS, FOR NEW LAYOUT. SEE ADDITIONAL NOTES AT LEFT
MODIFY EXISTING FIRE SPRINKLER SYSTEM TO SERVE THE PROPOSED IMPROVEMENTS TO MEET CURRENT CODE REQUIREMENTS.
FIRE SPRINKLER IMPROVEMENTS SHALL BE DESIGN/BUILD BY CONTRACTOR WITH QUALIFIED SUBCONTRACTOR. SUBMIT
DESIGN/DRAWINGS TO BUILDING AND FIRE DEPARTMENTS FOR APPROVAL.
1
2
SECOND FLOOR IS ALL OFFICE SPACE - B OCCUPANCY
FIRST FLOOR IS COMBINATION OF VEHICLE STORAGE -
S-2 OCCUPANCY AND OFFICE SPACE - B OCCUPANCY
III-B
BETWEEN NEW SECOND FLOOR OFFICE AND
FIRST FLOOR STORAGE - 2 HOURS, REDUCED TO
1-HOUR FOR FIRE SPRINKLERS
SEPARATION REQUIREMENT
SITE
Sheet number:
Sheet title:
Project:
Print Date:
Drawn By:
Issue: Date: Revision: Date:
BID SET 07/02/15
MT
EAGLE COUNTY AIRPORT
ADMINISTRATION OFFICE
REMODEL
A-1
TITLE SHEET
7/6/15
715 W. Main Street, Suite 104 Aspen, Colorado 81611voice: 970.544.4851 email: [email protected]
12
3
4
5
8
7
9
W5
W2
W1
W5
W5
W5
W5
W1
W3
W4
W4
1
A-4
1
A-4
6A-6
1N
2EA-6
W1
A-6
1N
3EA-6
2N
A-6
W1
6'-0"
± 15'-4
3/8
"3 5
/8"
3'-10
"3 5
/8"
3 5
/8"
18'-1 7/8
"3 5
/8"
1'-9
"3 5
/8"
3'-1 1/2" 3 5/8"
12'-1 1/2" 3 5/8"
EQ. (±9'-6 1/4") 3 5/8" EQ. (± 9'-6 1/4" ) 9'-9 3/4"3 5/8"
3'-6
"3 5
/8"
± 6
'-8
5/8
"
FROM EXISTING
PARTITION
3 5/8"
ALIGN
A
1
2
3
5
1
4
5
B D
A DC
A
1
2
3
5
1
4
5
B D
A DC
2'-0
"
EXIS
TIN
G
CM
U R
.O.
6'-8"
2'-0
"
± 6
'-4
5/8
"
(R.O
.)
10"± 8'-4 1/4" R.O.4"
6"5'-8"6"
1 1/
2"
MASONRY R.O. 6'-8"
± 1 1/2"
4" ± 9'-1 1/8" R.O. 4"
ALIGN F.O.S. WITH FACE
OF MASONRY OPENING
± 2'-5 3/4"
(R.O.)
4"
EXISTING PARTITION TO REMAIN
EXISTING PARTITION TO BE REMOVED
PROPOSED PARTITION, ALL NEW PARTITIONS
SHALL EXTEND 6" ABOVE SUSPENDED CLG.
TYPICAL NON-STRUCTURAL STEEL STUD
SHALL BE 362S125-30
WALL TYPE LEGEND
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
FINISH ENDS OF CMU WALL WITH DRYWALL TO
MATCH ADJOINING SURFACES.
FRAME-IN EXISTING OPENING. FINISH TO MATCH
ADJOINING SURFACES.
FINISH AND PATCH AREAS OF NEW WORK
(WALLS, FLOOR AND CEILING) TO BLEND
SEAMLESSLY WITH EXISTING CONSTRUCTION,
TYPICAL.
EXISTING STOREFRONT PARTITION TO REMAIN.
NEW STOREFRONT PARTITION TO MATCH EXISTING
IN MANUFACTURER (KAWNEER), STYLE/MODEL
AND FINISH.
CHANGE IN FLOORING MATERIAL.
INSULATE ALL NEW PARTITIONS AND FRAMED-IN
OPENINGS FOR SOUND WITH FIBER BATT
INSULATION, FULL DEPTH OF STUD CAVITY, AND
SEAL PERIMETER WITH ACOUSTICAL SEALANT,
TYPICAL.
EXISTING DOOR TO REMAIN, ALL DOORS WITH A
DOOR SYMBOL INDICATE NEW DOOR, SEE DOOR
SCHEDULE.
DASHED LINE INDICATES EXISTING ROOF
OVERHANG ABOVE.
DASHED RECTANGLE INDICATES OBSERVATION
DECK SHAFT OPENING ABOVE.
EXISTING LADDER TO REMAIN.
FIX EXISTING GARAGE DOOR IN PLACE AND SEAL.
REMOVE SECTION OF TRACK AND OPERATOR
THAT CONFLICTS WITH NEW CONSTRUCTION.
RESILIENT CHANNEL ON THIS SIDE OF WALL, SEE
WALL ASSEMBLIES.
NEW 3/4" STEEL FURRING WITH DRYWALL FINISH
OVER EXISTING CMU WALL. WEST AND NORTH
WALLS OF CHASE.
NEW 18" DEEP FIXED, BUILT-IN PAINT-GRADE
SHELVING.
NEW STEEL COLUMN AND BEAM ABOVE, SEE
STRUCTURAL
KEYNOTES
PROPOSED SECOND FLOOR PLANSCALE: 1/4" = 1'-0"4
DN.
EXISTING/DEMO SECOND FLOOR PLANSCALE: 1/4" = 1'-0"3
DECK
KITCHENETTE
CHASE
STORAGE
AVIATION DIRECTOR
CONFERENCE
ROOM
STAIR 2
PROJECT
COORDINATOR
ADMIN. ASST.
BADGING
ADMIN. MGR.ASST. AVIATION
DIRECTOR
RECEPTION
MEN'S
TOILET ROOM
WOMEN'S
TOILET ROOM
STAIR 1
ELECTRICAL
ROOM
OPEN TO BELOW
DN.
DECK
CONFERENCE
ROOM
BADGING
ELECTRICAL
ROOM
KITCHENETTE
STORAGE
STAIR 2
ASST. AVIATION
DIRECTOR
ADMIN. MGR.
AVIATION
DIRECTOR
RECEPTION
MARKETING
ADMIN. ASST.
STORAGE
ROOM
MEN'S
TOILET ROOM
WOMEN'S
TOILET ROOM
STAIR 1
OPEN TO BELOW
OPERATIONS
MANAGER
CHASE
REMOVE ALL COMPONENTS/FIXTURES SHOWN
DASHED, TYPICAL.
REMOVE EXISTING DOOR AND FRAME.
REMOVE EXISTING CARPET THROUGHOUT SECOND
FLOOR.
GARAGE DOOR TO REMAIN BUT TRIM TRACK TO
ALLOW FOR NEW CONSTRUCTION. FIX GARAGE
DOOR IN PLACE.
REMOVE AND RELOCATE EXISTING MECHANICAL
EQUIPMENT PER MECHANICAL PLANS.
EXISTING DUCT TO REMAIN, SEE MECHANICAL.
REMOVE UPPER CABINETS ALONG NORTH WALL.
REMOVE EXISTING WOOD BASE IN AREAS OF
NEW WORK.
REMOVE PORTION OF EXISTING RESILIENT
FLOORING AT STAIR 2 THAT WILL BECOME
HALLWAY.
REMOVE EXISTING STOREFRONT AND REUSE TO
NEW SIZE IF IN GOOD CONDITION.
REMOVE EXISTING ROOF INSULATION ON THIS
AREA AND REPLACE WITH NEW ROOF INSULATION
D1
D2
D3
D4
D5
D6
D7
D8
D9
D10
D11
DEMOLITION KEYNOTES
PROPOSED PARTIAL FIRST FLOOR PLANSCALE: 1/4" = 1'-0"2
EXISTING/DEMO PARTIAL FIRST FLOOR PLANSCALE: 1/4" = 1'-0"1
STORAGE STORAGE
HALLWAY
PROJECT
COORDINATOR
DN. DN.
EXISTING CMU PARTITION TO REMAIN
14
14
D1
D1
D2
D2 D2
D3
D3
D3
D4
D5
D6
D6
D7
2
1
3
3
3
3
4
5
5
5
6
7
7
7
7
7
7
9
9
10
11
12
13
13
13
13
13
8
8
8
8
OPEN OFFICE
CLOSET
D9
D10
OPEN OFFICE
D11
15
16
1
5/8" FROM EDGE
OF LANDING
Sheet number:
Sheet title:
Project:
Print Date:
Drawn By:
Issue: Date: Revision: Date:
BID SET 07/02/15
LM & MT
EAGLE COUNTY AIRPORT
ADMINISTRATION OFFICE
REMODEL
A-2
EXISTING & PROPOSED
FLOOR PLANS
7/6/15
715 W. Main Street, Suite 104 Aspen, Colorado 81611voice: 970.544.4851 email: [email protected]
1
A-4
EQ. EQ. EQ. EQ.
A
1
2
3
5
1
4
5
B D
A DC
A
1
2
3
5
1
4
5
B D
A DC
EQ
.EQ
.
PROPOSED SECOND FLOOR REFLECTED CEILING PLANSCALE: 1/4" = 1'-0"2
CONFERENCE
ROOM
BADGING
KITCHENETTE
STORAGE
ASST. AVIATION
DIRECTOR
ADMIN.
MGR.
AVIATION
DIRECTOR
RECEPTION
STORAGE
STAIR 1
EXISTING SECOND FLOOR REFLECTED CEILING PLANSCALE: 1/4" = 1'-0"1
OPEN TO BELOW
KITCHENETTE
CHASE
STORAGE
AVIATION
DIRECTOR
CONFERENCE
ROOM
STAIR 2
RECEPTION
MEN'S
TOILET ROOM
WOMEN'S
TOILET ROOM
STAIR 1
ELEC. RM.
MEN'S
TOILET ROOM
WOMEN'S
TOILET ROOM
ELEC. RM.
STAIR 2
CHASE
SYMBOLS LEGEND
EXISTING 2' x 4' FLUORESCENT LIGHT
FIXTURE TO BE REMOVED
EXISTING SUPPLY AIR DIFFUSER TO REMAIN
OR TO BE REMOVED AND REINSTALLED AT
SAME LOCATION, SEE MECHANICAL PLAN
EXISTING RETURN AIR DIFFUSER TO REMAIN
OR TO BE REMOVED AND REINSTALLED AT
SAME LOCATION, SEE MECHANICAL PLAN
EXISTING SMOKE DETECTOR TO REMAIN
RECESSED DOWNLIGHT, SEE ELECTRICAL
PLAN
NEW 2' x 4' TROFFER LIGHT FIXTURE, SEE
ELECTRICAL PLANS
PROPOSED RETURN AIR DIFFUSER, SEE
MECHANICAL PLAN
KEYNOTES
1
2
3
4
SECURE SUSPENSION SYSTEM/WIRE/ROD
HANGERS, ETC. FOR THE CEILING TILES OR
GYPSUM BOARD TO STRUCTURAL MEMBERS OR
FRAMING MEMBERS ONLY. NEVER ATTACH THE
SUSPENDED STEEL FRAMING TO THE ROOF
DECKS OR TO THE DUCTS, PIPES AND CONDUITS.
INSTALL EDGE MOLDING AND TRIM AT PERIMETER
OF ACOUOSTICAL CEILING WHERE NECESSARY
TO CONCEAL EDGES OF ACOUSTICAL CEILING
TILES.
APPLY ACOUSTICAL SEALANT IN A CONTNUOUS
RIBBON FORM WHERE CEILING MEETS THE
VERTICAL WALLS.
LOCATE ELECTRICAL DEVICES, LIFE SAFETY
DEVICES AND THE SPRINKLER HEAD AT THE
CENTER OF THE ACOUSTICAL CELING TILES,
UNLESS OTHERWISE NOTED.
ACOUSTICAL CEILING
CRITERIA
1
2
3
4
5
6
7
8
TO FACILITATE INSTALLATION OF NEW
MECHANICAL SYSTEM REMOVE AND REPLACE
EXISTING SUSPENDED ACOUSTICAL BOARD AND
GRID CEILING THROUGHOUT SECOND FLOOR
EXCEPT AT STAIR AND ELECTRICAL ROOM.
NEW DRYWALL SOFFIT, SEE WALL SECTION.
NEW DRYWALL CEILING, SEE WALL SECTION.
EXISTING DRYWALL CEILING TO REMAIN.
EXISTING SUSPENDED ACOUSTICAL BOARD AND
GRID CEILING TO REMAIN. REPLACE ALL DAMAGED
OR MISSING TILES.
EXISTING EXIT SIGN TO BE REMOVED AND
REPLACED, SEE ELECTRICAL PLAN, TYPICAL.
EXISTING ELECTRICAL DEVICE, REMOVE AND
REINSTALL IF ACTIVE. FOR BIDDING PURPOSES,
ASSUME ALL DEVICES ARE ACTIVE. PRIOR TO
RE-INSTALLATION CONFIRM WITH OWNER IF
DEVICE IS NEEDED. PROVIDE CREDIT FOR ANY
DEVICES NOT REINSTALLED. TYPICAL.
NEW SUSPENDED ACOUSTICAL BOARD AND GRID
CEILING, TYPICAL.
E
N
NPROPOSED SUPPLY AIR DIFFUSER, SEE
MECHANICAL PLAN
S
APPROXIMATE LOCATION OF EXISTING FIRE
SPRINKLER HEAD, MODIFY EXISTING
SYSTEM TO NEW FLOOR PLAN LAYOUT
AND CODE REQUIREMENTS AS
DESIGN-BUILD.
HALLWAY
PROJECT
COORDINATOR
OPERATIONS
MANAGER
MARKETING
ADMIN. ASST.
E
E
NEW SMOKE DETECTOR, SEE ELECTRICAL
PLAN
P
BADGING
PROJECT
COORDINATOR
ADMIN. ASST.
ASST. AVIATION
DIRECTOR
ADMIN. MGR.
EXISTING EXHAUST FAN TO REMAIN
8
8
8
8
8
8
6
6
7
7
7
supply
supply
supply
supply
return
s s
return
supply
s
exit
supply
supply
supply
return
supply
supply
exit
s
return
s
s
sp
sp
s
s
supply
supply
s
sp
E E E
E E E
E E E
E E E
E
E E
E
E E
EE
exit
s
return
s
s
supply
return
exit
supply
s
supply
supply
s s
s
s s
sp
R
N
return
return
N
supply
N
N
return
N
return
supply
N
supply
N
supply
N
N
return
1
1
2
3
4
4
4
5
5
Sheet number:
Sheet title:
Project:
Print Date:
Drawn By:
Issue: Date: Revision: Date:
BID SET 07/02/15
LM & MT
715 W. Main Street, Suite 104 Aspen, Colorado 81611voice: 970.544.4851 email: [email protected] fax: 970.544.1915
EAGLE COUNTY AIRPORT
ADMINISTRATION OFFICE
REMODEL
7/6/15
A-3
EXISTING RCP,
PROPOSED RCP
± 8
'-0
" (M
ATC
H E
XIS
TIN
G)
6"
DIAGONAL BRACING TO
STRUCTURE ABOVE
7
A-4
NEW SUSPENDED ACOUSTICAL BOARD
AND GRID CEILING
NEW WALL FINISH MATERIAL, SEE
INTERIOR ROOM FINISH SCHEDULE,
TYPICAL
NEW STEEL STUDS AT 16" O.C.
NEW FIBER BATT INSULATION
NEW FLOOR FINISH MATERIAL, SEE
INTERIOR ROOM FINISH SCHEDULE
FLOOR SUBSTRATE (CONCRETE
OR WOOD)
RESILIENT CHANNELS AT 16" O.C.,
WHERE OCCURS
INSULATION
NOT SHOWN
INSULATION
NOT SHOWN
5/8" DRYWALL
HEADER
5/8" DRYWALL
HOLLOW METAL
DOOR FRAME
DOOR
HOLLOW METAL
DOOR FRAME
5/8" DRYWALL
DOOR
5/8" DRYWALL
INSULATION
NOT SHOWN
INSULATION
NOT SHOWN
5/8" DRYWALL
HEADER
5/8" DRYWALL
HOLLOW METAL
DOOR FRAME
DOOR
HOLLOW METAL
DOOR FRAME
5/8" DRYWALL
DOOR
5/8" DRYWALL
RESILIENT CHANNELS
AT 16" O.C.
RESILIENT CHANNELS
AT 16" O.C.
INSULATION
NOT SHOWN
5/8" DRYWALL
STEEL BASE TRACK
5/8" DRYWALL
RESILIENT CHANNELS
AT 16" O.C., WHERE
OCCURS
FLOOR SUBSTRATE (PLYWOOD OR
CONCRETE)
1/4
"
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT,
BOTH SIDES OF WALL
FLOOR FINISH MATERIAL
BASE NOT SHOWN
1"1"
4SCALE: 3" = 1'-0"
INTERIOR DOOR HEAD
3SCALE: 3" = 1'-0"
INTERIOR DOOR JAMB
2SCALE: 3" = 1'-0"
INTERIOR DOOR HEAD
5SCALE: 3" = 1'-0"
INTERIOR DOOR JAMB
SCALE: 3" = 1'-0"7
TYPICAL WALL TO FLOOR
SCALE: 3" = 1'-0"8
DETAIL
SCALE: 3/4" = 1'-0"6
TYPICAL INTERIOR PARTITION
F1
ELEV. 100'-0"
T.O. CONC. SLAB
ELEV. ±111'-10"
(ALIGN WITH TOP OF
EXIST. CONCRETE)
T.O. SHEATHING
± 11'-
10"
ELEV. 120'-0"
JOIST BEARING
20
'-0
"
± 8
'-0
"
(MA
TC
H E
XIS
TIN
G)
(VER
IFY
)
6'-9
"
2'-0"
1"
SCALE: 1/2" = 1'-0"
WALL SECTION1
EXISTING ROOF TO REMAIN
METAL DECK TO REMAIN
EXISTING TRUSS TO REMAIN
EXISTING SOFFIT TO REMAIN
WALL FINISH TO REMAIN
EXISTING CMU WALL TO REMAIN
EXISTING STEEL BEAM TO REMAIN
EXISTING FAUX HEADER TO REMAIN
EXISTING GARAGE DOOR
TO REMAIN, FIX IN PLACE
NEW PLYWOOD FLOOR SHEATHING,
SEE STRUCTURAL
NEW SUSPENDED ACOUSTICAL BOARD
AND GRID CEILING
OPERATIONS MANAGER
OFFICENEW R-13 FIBER BATT INSULATION
NEW WALL FINISH MATERIAL, SEE
INTERIOR ROOM FINISH
SCHEDULE, TYPICAL
NEW FLOOR FINISH MATERIAL, SEE
INTERIOR ROOM FINISH SCHEDULE
NEW 5/8" DRYWALL
STORAGE
NEW PLYWOOD WEB JOIST, SEE
STRUCTURAL
NEW R-19 FIBER BATT INSULATION
ONE LAYER OF TYPE 'X'
DRYWALL
EXISTING CONCRETE SLAB ON
GRADE TO REMAIN
NEW 3 5/8" STEEL
JOISTS AT 16" O.C.
NEW 5/8" DRYWALL
NEW STEEL STUDS AT
16" O.C.
NEW 1 1/2" WALL FURRING AT 16" O.C.
REMOVE EXISTING ROOF INSULATION
AND REPLACE WITH NEW INSULATION
NEW UNFACED, FORMALDEHYDE FREE FIBER BATT INSULATION
FULL DEPTH OF STEEL BAR JOISTS AND THERMAL BLOCK (±21"
OF INSULATION, ±R-65).
NEW CONTINUOUS THERMAL
BLOCK AT BOTTOM CHORD
NEW CONTINUOUS VAPOR BARRIER,
SEAL TO WALLS
NEW ROOF INSULATION SYSTEM ABOVE
OPERATIONS MANAGER AND PROJECT
COORDINATOR OFFICES SHALL BE SIMPLE SAVER
SYSTEM BY THERMAL DESIGN INCLUDING SYSEAL
FABRIC, STEEL SUPPORT STRAPS, FASTENERS &
SEALANTS.
FILL THE ENTIRE SPACE BETWEEN THE BAR JOISTS
AS WELL AS THE ENTIRE DEPTH OF THE BAR JOIST
WITH UNFACED FORMALDEHYDE FREE FIBER BATT
INSULATION TO ASSURE THE HIGHEST IN PLACE
R-VALUES AND TO HELP AVOID POSSIBLE
CONDENSATION PROBLEMS.
THE INSULATION SHALL REST ON THE LINER
FABRIC/VAPOR BARRIER BETWEEN THE JOISTS.
THE INSULATION SHALL FIT TIGHTLY TOGETHER
AROUND THE JOIST CHORDS.
A CONTINUOUS 1" THICK x WIDTH OF BOTTOM
CHORD TYPE II EXPANDED POLYSTYRENE (EPS)
THERMAL BLOCK SHALL BE INSTALLED TO THE
BOTTOM CHORD OF ALL BAR JOISTS BETWEEN
THE LINER FABRIC/VAPOR RETARDER AND THE
JOIST.
SEAL LINER FABRIC/VAPOR RETARDER AGAINST
WALLS AND ALL PENETRATIONS.
1
2
3
4
5
6
NEW ROOF INSULATION
Sheet number:
Sheet title:
Project:
Print Date:
Drawn By:
Issue: Date: Revision: Date:
BID SET 07/02/15
LM & MT
EAGLE COUNTY AIRPORT
ADMINISTRATION OFFICE
REMODEL
A-4
WALL SECTION, DETAILS
7/6/15
715 W. Main Street, Suite 104 Aspen, Colorado 81611voice: 970.544.4851 email: [email protected]
FRAMED FLOOR (1-HR. 55 TO 59 STC SOUND)
FINISH FLOORING MATERIAL, SEE INTERIOR ROOM FINISH SCHEDULE
GA FILE NO. FC 5106
BASE LAYER 1/2" TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT ANGLES TO RESILIENT
CHANNELS 16" O.C. WITH 11/4" TYPE S DRYWALL SCREWS 12" O.C. RESILIENT CHANNELS
APPLIED AT RIGHT ANGLES TO MINIMUM 91/2" DEEP WOOD I-JOISTS, WITH MINIMUM 11/4" DEEP
X 11/2" WIDE FLANGES AND MINIMUM 3/8" WEBS, 24" O.C. WITH 11/4" TYPE W DRYWALL
SCREWS. FACE LAYER 1/2" TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT ANGLES TO
CHANNELS WITH 15/8" TYPE S DRYWALL SCREWS 12" O.C. FACE LAYER END JOINTS
LOCATED MIDWAY BETWEEN CHANNELS AND ATTACHED TO BASE LAYER WITH 11/2" TYPE G
SCREWS 12" O.C. EDGE JOINTS OFFSET 24" FROM BASE LAYER EDGE JOINTS. WOOD
I-JOISTS SUPPORTING 5/8" ORIENTED STRAND BOARD APPLIED AT RIGHT ANGLES TO I-
JOISTS WITH 8D COMMON NAILS 12" O.C.
STC AND IIC TESTED BOTH WITH AND WITHOUT VINYL FLOOR COVERING AND WITH 31/2"
GLASS FIBER INSULATION IN JOIST SPACES. THIRD LAYER OF 1/2" OR 5/8" TYPE X GYPSUM
WALLBOARD REQUIRED TO ACHIEVE 1 HOUR FIRE RESISTANCE RATING WHEN GLASS FIBER
INSULATION IS USED.
TYPICAL INTERIOR WALL
INTERIOR WALL FINISH MATERIAL, SEE
INTERIOR ROOM FINISH SCHEDULE
3 5/8" STEEL STUDS AT 16" O.C.
FIBER BATT INSULATION (FORMALDEHYDE FREE,
FOR SOUND), FULL DEPTH OF STUD CAVITY
INTERIOR WALL FINISH MATERIAL, SEE
INTERIOR ROOM FINISH SCHEDULE
EXISTING CMU WALL WITH FURRING
(BOTH SIDES)
NEW INTERIOR WALL FINISH MATERIAL, SEE
INTERIOR ROOM FINISH SCHEDULE
NEW 1 1/2" FURRING CHANNELS AT 16" O.C.
NEW FIBER BATT INSULATION (FORMALDEHYDE FREE,
FOR SOUND)
EXISTING CMU
NEW FIBER BATT INSULATION (FORMALDEHYDE FREE,
FOR SOUND) IF EXISTING DRYWALL IS REMOVED
EXISTING 1 1/2" FURRING CHANNEL (VERIFY), TO REMAIN
EXISTING INTERIOR WALL FINISH MATERIAL, SEE
INTERIOR ROOM FINISH SCHEDULE
EXISTING CMU WALL WITH FURRING
EXISTING CMU
NEW FIBER BATT INSULATION (FOR SOUND)
NEW 1 1/2" FURRING CHANNEL
NEW INTERIOR WALL FINISH MATERIAL, SEE
INTERIOR ROOM FINISH SCHEDULE
INSULATION
NOT SHOWN
5/8" DRYWALL
HOLLOW METAL
DOOR FRAME
DOOR
5/8" DRYWALL
INSULATION
NOT SHOWN
5/8" DRYWALL
DOOR
5/8" DRYWALL
4" M
IN.
1/4
"
SH
IM
METAL L-TRIM
INSULATION
NOT SHOWN
5/8" DRYWALL
HEADER
DOOR
5/8" DRYWALL
HEMMED ANGLE MOLDING, TYPICAL
AT CEILING TO WALL
NEW SUSPENDED ACOUSTICAL
BOARD AND GRID CEILING, SEE
REFLECTED CEILING PLANNEW 3 5/8" STEEL
STUDS AT 16" O.C.
METAL L-TRIM
INSULATION
NOT SHOWN
5/8" DRYWALL
HEADER
5/8" DRYWALL
NEW SUSPENDED ACOUSTICAL
BOARD AND GRID CEILING, SEE
REFLECTED CEILING PLANNEW 3 5/8" STEEL
STUDS AT 16" O.C.
METAL L-TRIM
1/2" S
HIM
INSULATION
NOT SHOWN
5/8" DRYWALL5/8" DRYWALL
1/4
"
SH
IM
METAL L-TRIM
1/2" S
HIM
CARPET
1/4
" S
HIM
STOREFRONT FRAME
INTERIOR WALL (1-HR)
GA FILE NO. WP 1072
ONE LAYER 5/8" TYPE 'X' GYPSUM
WALLBOARD OR GYPSUM VENEER BASE
APPLIED PARALLEL OR AT RIGHT ANGLES
TO EACH SIDE OF 3 5/8" STEEL STUDS OR
2x WOOD STUDS AT 16" O.C. WITH 1" TYPE
'S' DRYWALL SCREWS 8" O.C. AT
VERTICAL JOINTS AND 12" O.C. AT FLOOR
AND CEILING RUNNERS AND
INTERMEDIATE STUDS.
JOINTS STAGGERED 24" ON EACH SIDE
AND ON OPPOSITE SIDES.
FIBER BATT INSULATION (FORMALDEHYDE
FREE, FOR SOUND), FULL DEPTH OF STUD
CAVITY
INTERIOR WALL WITH RESILIENT
CHANNELS
INTERIOR WALL FINISH MATERIAL, SEE
INTERIOR ROOM FINISH SCHEDULE
1/2" SINGLE LEG RESILIENT CHANNEL AT 16" O.C.,
PERPENDICULAR TO STUDS (SCREW ATTACHMENT)
3 5/8" STEEL STUDS AT 16" O.C.
FIBER BATT INSULATION (FOR SOUND) FULL DEPTH
OF STUD CAVITY
INTERIOR WALL FINISH MATERIAL, SEE
INTERIOR ROOM FINISH SCHEDULE
INSULATION
NOT SHOWN
5/8" DRYWALL
HOLLOW METAL
DOOR FRAME
DOOR
5/8" DRYWALL
RESILIENT CHANNELS
AT 16" O.C.
1"1"
INSULATION
NOT SHOWN
5/8" DRYWALL
HOLLOW METAL
DOOR FRAME
DOOR
5/8" DRYWALL
RESILIENT CHANNELS
AT 16" O.C.
1"3" M
IN.
4" M
IN.
HEMMED ANGLE MOLDING, TYPICAL
AT CEILING TO WALL
STOREFRONT FRAME
STOREFRONT FRAME
STOREFRONT FRAME
STOREFRONT FRAME
3" M
IN.
3" M
IN.
W3SCALE: 3" = 1'-0"
WALL ASSEMBLY (PLAN VIEW)
W2SCALE: 3" = 1'-0"
WALL ASSEMBLY (PLAN VIEW)
W1SCALE: 3" = 1'-0"
WALL ASSEMBLY (PLAN VIEW)
W4SCALE: 3" = 1'-0"
WALL ASSEMBLY (PLAN VIEW)
W5SCALE: 3" = 1'-0" SCALE: 3" = 1'-0"4
STOREFRONT DOOR HEAD
SCALE: 3" = 1'-0"5
STOREFRONT DOOR JAMB
SCALE: 3" = 1'-0"6
STOREFRONT HEAD
SCALE: 3" = 1'-0"7
STOREFRONT JAMB
SCALE: 3" = 1'-0"10
INTERIOR DOOR JAMB TO WALL
SCALE: 3" = 1'-0"11
INTERIOR DOOR JAMB TO WALL
SCALE: 3" = 1'-0"9
STOREFRONT WINDOW HEAD
SCALE: 3" = 1'-0"8
STOREFRONT SILL
SCALE: 3" = 1'-0"F1
FLOOR ASSEMBLY
SCALE: 3" = 1'-0"2
DOOR JAMB
SCALE: 3" = 1'-0"3
DETAIL
WALL ASSEMBLY (PLAN VIEW)
Sheet number:
Sheet title:
Project:
Print Date:
Drawn By:
Issue: Date: Revision: Date:
BID SET 07/02/15
MT
EAGLE COUNTY AIRPORT
ADMINISTRATION OFFICE
REMODEL
A-5
ASSEMBLIES, DETAILS
7/6/15
715 W. Main Street, Suite 104 Aspen, Colorado 81611voice: 970.544.4851 email: [email protected]
5
A-5
4
A-5
6
A-5
7
A-5
8
A-5
8
A-5
7
A-5
SIM.
6
A-5
8
A-5
6
A-5
7
A-5
SIM.
SIM.
SIM.
5" 5"
5"
10"
7'-0
"
3'-0"
7'-0
"
3'-0"
1 3/4" 1 3/4"± 4'-10 1/2" ± 5'-7 3/8"1 3/4" 1 3/4"± 3'-0" 3'-0"1 3/4" 1 3/4"
± 8'-3 3/4" ± 9'-0 5/8"
1 3/4
"± 2
'-2 1/2
"1 3/4
"± 4
'-6
"1 3/4
"
(MA
TC
H E
XIS
T.)
(MA
TC
H E
XIS
T.)
(MA
TC
H E
XIS
T.)
(MA
TC
H E
XIS
T.)
7'-1 3/4
"
1 3/4" 3'-0 3/8" 1 3/4" 3'-0 3/8"
± 6'-4 3/8"
1 3/4
"± 2
'-2 1/2
"1 3/4
"± 4
'-6
"1 3/4
"
(MA
TC
H E
XIS
T.)
(MA
TC
H E
XIS
T.)
7'-1 3/4
"
1 3/4
"± 2
'-2 1/2
"1 3/4
"± 4
'-6
"1 3/4
"
7'-1 3/4
"
± 2'-0"
REFRIGERATOR
SPACE FOR 24"
WIDE REFRIG.
± 8 5/8"
4 1/2"
1 3/4
"± 2
'-2 1/2
"1 3/4
"± 4
'-6
"1 3/4
"
(MA
TC
H E
XIS
T.)
(MA
TC
H E
XIS
T.)
7'-1 3/4
"
(FIT DOOR) (FIT DOOR)
± 2'-3 3/4" 1 3/4"
4 1/2" ± 2'-5 1/2"
(VERIFY)
1HALLWAY
SCALE: 1/2" = 1'-0"
NORTH
2HALLWAY
SCALE: 1/2" = 1'-0"
EAST
4DOOR TYPES
TYPE 'A' TYPE 'B'
SCALE: 1/2" = 1'-0"
NEW CORNER JAMB OR
MODIFY EXISTING
3KITCHENETTE
SCALE: 1/2" = 1'-0"
EAST
WIDEN REFRIGERATOR
SPACE BY REMOVING
AND REPLACING
DRAWER CABINET
DASHED LINE INDICATE
EXISTING BANK OF
DRAWERS
REPLACE DRAWERS CABINET A
NEW BASE CABINET, WITH ADJ.
SHELF, TO MATCH EXISTING
NORTH
LOCATIONMARK TYPE WIDTH HEIGHT THICKNESS MATERIAL HARDWARE
1 CONFERENCE ROOM
FINISH FRAME FINISH HEAD JAMB SILL COMMENTS
DOOR TYPES:
DOOR SCHEDULE
REV.
2
3 STAIR 2
4 OPERATIONS MANAGER
5 PROJECT COORDINATOR
6
7
8
AVIATION DIRECTOR
ADMIN. MGR.
STORAGE
TYPE 'A': SINGLE LITE STILE AND RAIL WOOD DOOR: MARSHFIELD, OR EQUIVALENT, STILE AND RAIL SERIES, DESIGN K-6010 WITH W-8 MOULDING. FACTORY GLAZED WITH 1/4" CLEAR TEMPERED GLASS. FINAL WOOD VENEER SELECTION TO
BE DETERMINED BUT FOR BIDDING USE PLAIN SLICED WHITE MAPLE CLEAR. FIELD STAIN. SEE DOOR STYLE DRAWING AT LEFT.
TYPE 'B': FLUSH WOOD DOOR: MARSHFIELD, OR EQUIVALENT, SIGNATURE SERIES WOOD BASED PARTICLEBOARD CORE. FINAL WOOD VENEER SELECTION TO BE DETERMINED BUT FOR BIDDING USE PLAIN SLICED WHITE MAPLE CLEAR. FIELD
STAIN . SEE DOOR STYLE DRAWING AT LEFT.
TYPE 'C': FIRE RATED FLUSH WOOD DOOR: MARSHFIELD, OR EQUIVALENT, SIGNATURE SERIES WOOD BASED PARTICLEBOARD CORE, 60 MINUTE FIRE RATED. FINAL WOOD VENEER SELECTION TO BE DETERMINED BUT FOR BIDDING USE PLAIN
SLICED WHITE MAPLE CLEAR. FIELD STAIN . SEE DOOR STYLE DRAWING AT LEFT.
A STEEL, TYPE 13'-0" 7'-0" 1 3/4" PRIME AND PAINT
STEEL, TYPE 12'-4" 7'-0" 1 3/4"
STEEL, TYPE 23'-0" 7'-0" 1 3/4"
3'-0" 7'-0" 1 3/4"
ALUMINUM3'-0" 7'-0" 1 3/4" FACTORY PAINT
3'-0" 7'-0" 1 3/4"
A 3'-0" 7'-0" 1 3/4" PRIME AND PAINT
B 3'-0" 7'-0" 1 3/4" PRIME AND PAINT
4/A-4 5/A-4 & 2/A-5 - -
CONFERENCE ROOM B
B
A
A
A
WOOD
WOOD
WOOD & GLASS STAIN
STAIN
STAIN
STAIN
STAIN
STAIN
STAIN
PRIME AND PAINT
PRIME AND PAINT
PRIME AND PAINT
PRIME AND PAINT
ROOM FINISH SCHEDULE
ROOMREV
FLOORS
MTRL BASENORTH
MTRL FIN. MTRL FIN.
EAST
WALLS
SOUTH WEST
CEILINGS
MTRL FIN. COMMENTS
MTRL FIN. MTRL FIN.
OPEN OFFICE (INCLUDES RECEPTION,
BADGING, ADMIN. ASST. & MARKETING)
RM #
NOTE 1 NOTE 2 DW NOTE 1 ACT - -
NOTES:
CONFERENCE ROOM
ASSISTANT AVIATION DIRECTOR
FINISH MATERIALS SPECIFICATIONSDESCRIPTIONREV SIZE COMMENTSMARK MANUF./MTRL. MANF'R # COLOR SIZE
1.
2.
3.
AVIATION DIRECTOR
PROJECT COORDINATOR
OPERATIONS MANAGER
NOTES:
1.
PATCH, OR REPLACE (CONTRACTOR'S OPTION), EXISTING DRYWALL ON PARTITIONS TO REMAIN AND NEW DRYWALL ON NEW PARTITIONS.
PATCH, OR REPLACE (CONTRACTOR'S OPTION), EXISTNG DRYWALL ON PARTITIONS TO REMAIN AND NEW DRYWALL OVER NEW FURRING ON EXISTING EXPOSED CMU WALL AT CHASE.
PATCH, OR REPLACE (CONTRACTOR'S OPTION), EXISTING DRYWALL.
ETR EXISTING TO REMAIN - - - - - -- -
PAINT PAINT ULTRA SPEC 500 N 537 (LOW SHEEN)
AND N539 (SEMI GLOSS)
LINEN WHITE - -BENJAMIN MOORE
TYPICAL NOTES:
1.
2.
3.
REMOVE AND REPLACE AS MUCH DRYWALL FINISH AS NEEDED TO EXECUTE PROPOSED WORK. CONTRACTOR'S DISCRETION TO LEAVE OR REPLACE ANY AND ALL EXISTING DRYWALL ON WALL SURFACES WHERE NEW WORK IS MINIMAL. ANY
EXISTING DRYWALL THAT REMAINS MUST BLEND SEAMLESSLY WITH NEW DRYWALL. PATCH/REPAIR ANY IMPERFECTIONS/DAMAGE TO EXISTING DRYWALL THAT REMAINS AND TEXTURE TO BLEND SEAMLESSLY WITH NEW DRYWALL.
PAINT ALL EXISTING WOOD WINDOW CASING/TRIM (WINDOWS ARE ALUMINUM, DO NOT PAINT WINDOWS).
PAINT ALL EXISTING WOOD DOORS, FRAMES AND CASING TO REMAIN.
NOTE 3 NOTE 3DWDW - -
NOTE 3 PAINT NOTE 3 PAINT - -
ACT - -
DW GYPSUM DRYWALL - - - - 5/8"AMERICAN GYPSUM TEXTURE TO MATCH EXISTING.
NOTE 3 PAINT DW PAINT NOTE 3 PAINT
CARPET CARPET GL 149 WAVELENGTH BILLOW - 665 - -MOHAWK GROUP
ADMINISTRATIVE MANAGER - -
PAINT PAINTPAINTPAINT
PAINT PAINT PAINT PAINT
PAINT PAINT PAINT - -
ACT ACOUSTICAL CEILING TILE (NEW) CIRRUS TEGULAR #534 PANELS
W/ PRELUDE XL 15/16" TEE SYSTEM
WHITE 2'x4'ARMSTRONG
ACT (E) ACOUSTICAL CEILING TILE (EXISTING
TO REMAIN)
EXISTING EXISTING 2'x4'EXISTING REPLACE ANY AND ALL DAMAGED TILES AND GRID WITH NEW TILES
AND GRID TO MATCH EXISTING.
STORAGE ROOM
KITCHENETTE
CARPET VB
ACT
ACT - -PAINT PAINT PAINT PAINT
ACT - -PAINT
PAINT PAINT ACT
PAINT PAINT ACT
ETR ETR PAINTETRPAINTETR ETR
VCT PAINT PAINTPAINTDW PAINT - -ACT
9
ASST. AVIATION DIRECTOR
WOOD & GLASS
WOOD & GLASS
WOOD & GLASS
WOOD & GLASS
WOOD & GLASS
WOOD
A 3'-0" 7'-0" 1 3/4" STAIN
PAINT
PRIME AND PAINT
HALLWAY
VCT VINYL COMPOSITION TILE MATCH EXISTING MATCH EXISTING 12x12MATCH EXISTING MATCH VCT AND VINYL BASE IN EXISTING WOMEN'S TOILET ROOM.
VB COLOR INTEGRATED VINYL BASE COVE PROFILE STD. COLOR, TBD 4" TALLARMSTRONG
DW DW ACT - -PAINT PAINT PAINT PAINT
4/A-4 5/A-4, 11/A-5 - -
2/A-4 3/A-4, 10/A-5 - -
4/A-4 5/A-4, 11/A-5 - -
4/A-5 5/A-5 - -
4/A-5 5/A-5 - -
2/A-4 3/A-4, 10/A-5 - -
2/A-4 3/A-4, 10/A-5 - -
2/A-4 3/A-4 - -
STAIR 2
WOMEN'S TOILET ROOM
MEN'S TOILET ROOM
ELECTRICAL ROOM
STAIR 1
STORAGE
ETR ETR & VINYL ETRETR & GWB PAINT PAINTETR & GWB ETR ETR
ETR ETR ETR ETRETR ETR ETR
ETR ETR ETR ETRETR ETR ETR
ETR ETR ETR - - - -ETRETR - - ETR - - ETR - -
ETR ETR ETR - - - -ACT (E)ETR - - ETR - - ETR - -
ETR ETRETR ETR ETR
DW
DW
DW
DW
DW
DW
DW
DW
DW
DW
DW
DW
DW
DW
DW
DW
DW
DW
CLOSET DW DW ACT - -PAINT PAINT PAINT PAINTDW DW
NEW VINYL BASE AT STAIR LANDING SHALL
MATCH EXISTING.
DRYWALL AT SOFFIT CEILING AND CEILING ON
OTHER SIDE OF NORTH WALL, PAINT.
DRYWALL AT SOFFIT CEILING AND CEILING ON
OTHER SIDE OF NORTH WALL, PAINT.
PAINT PAINTNOTE 3 DW
NOTE 3
PAINT PAINTPAINT FINISH FRAMED-IN OPENING TO MATCH EXISTING.
PAINTPAINT PAINTPAINT PAINT
PAINTPAINT PAINTPAINT PAINT
PAINTPAINT PAINTPAINT PAINT
PAINTPAINT PAINT
PRIMER AND PAINT COATS AND THICKNESSES: LATEX PRIMER 1.4 TO 1.7 DRY MILS. INTERMEDIATE: ACRYLIC PAINT; 1.5 TO 1.7 DRY MILS. FINISH COAT: ACRYLIC PAINT 1.5 TO 1.7 DRY MILS; 1.5 TO 1.7 DRY MILS. SHEEN: LOW SHEEN (EGGSHELL)
THROUGHOUT EXCEPT AS NOTED. TOILET ROOMS, KITCHENETTE, AND INTERIOR DOORS AND FRAMES: SEMI-GLOSS.
PRIMER PRIMER ULTRA SPEC 500 N534 - - - -BENJAMIN MOORE
SEE NOTE 1 BELOW.
SEE NOTE 1 BELOW.
VB
VB
VB
VB
VB
VB
VB
VB
VB
VB
VB
CARPET
CARPET
CARPET
CARPET
CARPET
CARPET
CARPET
CARPET
CARPET
DOOR FRAME TYPES:
TYPE '1': DOUBLE RABBET NON-RATED STEEL FRAME. CECO, OR EQUIVALENT, SERIES BQ, 18 GAUGE.
TYPE '2': DOUBLE RABBET 60-MINUTE RATED STEEL FRAME. CECO, OR EQUIVALENT, SERIES BQ, 18 GAUGE (VERIFY GAUGE WITH FIRE RATING REQUIREMENT).
STEEL, TYPE 1
STEEL, TYPE 1
ALUMINUM
STEEL, TYPE 1
STEEL, TYPE 1
HARDWARE SCHEDULE:
HARDWARE SET 1: (DOOR 1)
HINGES: STANLEY 5 KNUCKLE CB FULL MORTISE HINGE: CB191-32D
LATCH SET: BEST ACCESS SYSTEMS CYLINDRICAL LOCK, PASSAGE FUNCTION: 9K-3-0-N-16-C-S3-626
WALL STOP: IVES WS447-US26D (SATIN CHROME)
ACOUSTIC SEAL SET: PEMKOSTCSET-1A (GASKETING: S773BL (SINGLE ROW) AND S44BL (SINGLE ROW), DOOR
BOTTOM: PDB411AE, CORNER PAD: ACP112BL
PASSAGE
HDWE SET
1
HARDWARE SET 2: (DOOR 2)
HINGES: STANLEY 5 KNUCKLE CB FULL MORTISE HINGE: CB191-32D
LATCH SET: BEST ACCESS SYSTEMS CYLINDRICAL LOCK, PASSAGE FUNCTION: 9K-3-0-N-16-C-S3-626
WALL STOP: IVES WS447-US26D (SATIN CHROME)
HARDWARE SET 3: (DOOR 3)
HINGES: STANLEY 5 KNUCKLE CB FULL MORTISE HINGE: CB191-32D
LATCH SET: BEST ACCESS SYSTEMS CYLINDRICAL LOCK, PROVIDE SAME FUNCTION AS EXISTING LATCH SET
WALL STOP: IVES WS447-US26D (SATIN CHROME)
GASKET: SMOKE SEAL AT HEAD AND JAMBS
DOOR BOTTOM: PEMKO 411 ARL AUTOMATIC DOOR BOTTOM
CLOSER: LCN CLOSERS, 1260 SERIES. HINGE PULL SIDE MOUNTING. POWDER COAT FINISH.
HARDWARE SET 4: (DOORS 4 & 7)
HINGES: STANLEY 5 KNUCKLE CB FULL MORTISE HINGE: CB191-32D
LATCH SET: BEST ACCESS SYSTEMS CYLINDRICAL LOCK, OFFICE FUNCTION: 9K-3-7-B-16-C-S3-626
WALL STOP: IVES WS447-US26D (SATIN CHROME)
ACOUSTIC SEAL SET: PEMKOSTCSET-1A (GASKETING: S773BL (SINGLE ROW) AND S44BL (SINGLE ROW), DOOR
BOTTOM: PDB411AE, CORNER PAD: ACP112BL
PASSAGE
LOCKSET
LOCKSET
LOCKSET
LOCKSET
LOCKSET
2
3
4
5
5
4
6
7
HARDWARE SET 5: (DOORS 5 & 6)
HINGES: STANLEY 5 KNUCKLE CB FULL MORTISE HINGE: CB191-32D
LATCH SET: BEST ACCESS SYSTEMS CYLINDRICAL LOCK, OFFICE FUNCTION: 9K-3-7-B-16-C-S3-626
WALL STOP: IVES WS447-US26D (SATIN CHROME)
GASKET: ACOUSTIC GASKETING/WEATHERSTRIPPING AT JAMBS AND HEAD BY STOREFRONT SUPPLIER
DOOR BOTTOM: PEMKO PDB411AE
HARDWARE SET 6: (DOOR 8)
HINGES: STANLEY 5 KNUCKLE CB FULL MORTISE HINGE: CB191-32D
LATCH SET: BEST ACCESS SYSTEMS CYLINDRICAL LOCK, OFFICE FUNCTION: 9K-3-7-B-16-C-S3-626
FLOOR STOP: IVES FS410-US26D (SATIN CHROME) DECORATIVE FLOOR STOP
ACOUSTIC SEAL SET: PEMKOSTCSET-1A (GASKETING: S773BL (SINGLE ROW) AND S44BL (SINGLE ROW), DOOR
BOTTOM: PDB411AE, CORNER PAD: ACP112BL
LOCKSET
HARDWARE SET 7: (DOOR 9)
HINGES: STANLEY 5 KNUCKLE CB FULL MORTISE HINGE: CB191-32D
LATCH SET: BEST ACCESS SYSTEMS CYLINDRICAL LOCK, STOREROOM FUNCTION: 9K-3-7-RZ-16-C-S3-626
FLOOR STOP: IVES FS410-US26D (SATIN CHROME) DECORATIVE FLOOR STOP
HARDWARE SET 8: EXISTING MEN'S AND WOMEN'S TOILET ROOM DOORS TO REMAIN - REPLACE EXISTING LATCH
SETS TO MATCH NEW ONES
LATCH SET: BEST ACCESS SYSTEMS CYLINDRICAL LOCK, PRIVACY FUNCTION: 9K-3-0-L-16-C-S3-626
HARDWARE SET 9: EXISTING ELECTRICAL ROOM DOOR TO REMAIN - REPLACE EXISTING LATCH
SET TO MATCH NEW ONES
LATCH SET: BEST ACCESS SYSTEMS CYLINDRICAL LOCK, STOREROOM FUNCTION: 9K-3-7-RZ-16-C-S3-626
SEE HARDWARE SCHEDULE BELOW FOR NEW LATCH SETS FOR EXISTING DOORS TO REMAIN
1/4" CLEAR TEMPERED GLASS
TYPICAL
ALUMINUM STOREFRONT FRAME,
TYPICAL
NEW END PANEL, TO MATCH
EXISTING, WHERE UPPER
CABINETS REMOVED
EXISTING UPPER CABINETS
TO REMIAN
EXISTING BASE
CABINET TO REMAIN
EXISTING CORNER CABIENT
TO REMAIN
Sheet number:
Sheet title:
Project:
Print Date:
Drawn By:
Issue: Date: Revision: Date:
BID SET 07/02/15
MT
EAGLE COUNTY AIRPORT
ADMINISTRATION OFFICE
REMODEL
A-6
SCHEDULES, INTERIOR
ELEVATIONS
7/6/15
715 W. Main Street, Suite 104 Aspen, Colorado 81611voice: 970.544.4851 email: [email protected]
RADIANT FLOOR SUPPLY
RADIANT FLOOR RETURN
NOTE: ALL SYMBOLS SHOWN ON LEGEND
ARE NOT NECESSARILY USED.
CHILLED WATER RETURN
CHILLED WATER SUPPLY
HEATING WATER RETURN
HEATING WATER SUPPLY
MECHANICAL LEGEND
MEDIUM PRESSURE NATURAL GAS
SNOWMELT RETURN
SNOWMELT SUPPLY
GAS
HWS
T
A
B
HWR
CWS
CWR
SMS
SMR
RFS
RFR
G
MPG
PIPE RISER
PIPE DROP
PIPE TAKEOFF (FROM BOTTOM OF MAIN)
PIPE TAKEOFF (FROM TOP OF MAIN)
PIP END CAP
PIPE CONTINUATION
PIPE EXPANSION GUIDE
PIPE UNION
PIPE ANCHOR
FLEXIBLE PIPE CONNECTION
PIPE EXPANSION JOINT
POINT OF NEW CONNECTION
AIR VENT
PLUG VALVE
CHECK VALVE
BALL VALVE
BALANCING VALVE
BUTTERFLY VALVE
PRESSURE REDUCING VALVE
STRAINER
PRESSURE - TEMP. TAP
PRESSURE GAUGE
2-WAY CONTROL VALVE
3-WAY CONTROL VALVE
SUPPLY GRILLE
RETURN GRILLE
EXHAUST AIR
SUPPLY AIR
RETURN AIR
OUTDOOR AIR
SUPPLY AIR DAMPER
RETURN AIR DAMPER
SUPPLY DIFFUSER
OA
RA
SA
EA
RAD
SAD
SG
RG
SD
RETURN DIFFUSERRD
TRANSFER GRILLETG
TRANSFER DIFFUSERTD
THERMOSTAT
FIRE/SMOKE DAMPER
FIRE DAMPER
MOTOR OPERATED DAMPER (MOD)
MANUAL BALANCING DAMPER
TURNING VANES IN 90° ELBOW
??x??
DUCT SIZES ARE NET FREE AREA
1ST NO. IS DUCT WIDTH.
2ND NO. IS DUCT DEPTH.
SECTION THRU SUPPLY AIR DUCT
SECTION THRU RETURN/EXHAUST AIR DUCT
SUPPLY DUCT TURN DOWN
RETURN/EXHAUST DUCT TURN DOWN
CHANGE OF ELEVATION
FLEXIBLE DUCT CONNECTION
R/D
(D) DROP (R) RISE
SENSOR (CALL OUT ON DRAWINGS)
SUPPLY REGISTER/DIFFUSER/LOUVER
NECK SIZE
CFM-S
RETURN REGISTER/DIFFUSER/LOUVER
NECK SIZE
CFM-R
OUTSIDE AIR REGISTER/DIFFUSER/LOUVER
NECK SIZE
CFM-O.A.
EXHAUST REGISTER/DIFFUSER/LOUVER
NECK SIZE
CFM-E
UDOOR UNDERCUT CFM
(A) SECTION CUT LINE
(B) SHEET SHOWN ON
S
SECTION THRU ROUND DUCT
ROUND DUCT TURN DOWN
4-WAY CONTROL VALVE
FLOW REGULATOR VALVE
DIFFERENTIAL BYPASS VALVE
NATURAL GAS PRESSURE REGULATOR
THERMOMETER
M
SEQUENCE OF OPERATION:
FURNACES & CONDENSING UNITS:
THE FURNACES AND CONDENSING UNITS SHALL BE CONTROLLED BY HEATING AND COOLING 7-DAY
PROGRAMMABLE WALL MOUNTED THERMOSTATS.
EF-1:
THE EXHAUST FAN SHALL BE CONTROLLED ACCORDING TO A WALL MOUNTED THERMOSTAT.
MOTORIZED DAMPERS:
WHEN THE SPACE IS OCCUPIED, THE OUTSIDE AIR DAMPERS (MD-2 & MD-4) SHALL OPEN AND THE RETURN AIR
DAMPERS (MD-1 & MD-3) SHALL PARTIALLY CLOSE AS INDICATED IN THE DAMPER SCHEDULE. WHILE UNOCCUPIED,
THE OUTSIDE AIR DAMPERS SHALL CLOSE AND THE RETURN AIR DAMPERS SHALL FULLY OPEN.
MECHANICAL SPECIFICATIONS:
1. GENERAL:
a. FURNISH ALL LABOR, SUPERVISION, MATERIALS, EQUIPMENT AND FACILITIES
NECESSARY TO FURNISH, FABRICATE, DELIVER, STORE AND INSTALL ALL WORK NOTED
ON THE DRAWINGS AND/OR SPECIFIED HEREIN.
b. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL WORK NECESSARY TO MAKE A
COMPLETE SYSTEM WHETHER OR NOT SUCH DETAILS ARE MENTIONED IN THESE
SPECIFICATIONS OR SHOWN ON THE PLANS, BUT WHICH ARE OBVIOUSLY NECESSARY
TO MAKE A COMPLETE SYSTEM, EXCEPTING ONLY THOSE PORTIONS THAT ARE
SPECIFICALLY MENTIONED HEREIN OR PLAINLY MARKED ON THE ACCOMPANYING
DRAWINGS AS BEING INSTALLED UNDER ANOTHER SECTION OF THE SPECIFICATIONS.
2. WORKMANSHIP:
a. THE WORK SHALL BE ACCOMPLISHED IN A THOROUGH AND WORKMAN-LIKE MANNER
SATISFACTORY TO AND MEETING THE APPROVAL OF THE OWNER AND ARCHITECT.
3. MATERIALS:
a. ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND THE BEST OF THEIR RESPECTIVE
KIND, FREE FROM ALL DEFECTS AND OF THE MAKE AND QUALITY SPECIFIED.
4. SITE INSPECTION:
a. CONTRACTOR SHALL VISIT THE SITE OF WORK PRIOR TO SUBMISSION OF HIS BID AND
THOROUGHLY FAMILIARIZE HIMSELF WITH THE WORKING CONDITIONS & EXACT NATURE
OF THE WORK.
b. SUBMISSION OF A BID ACKNOWLEDGES FULL RESPONSIBILITY FOR FURNISHING A
COMPLETE AND FUNCTIONAL SYSTEM.
c. NO CHANGES IN CONTRACT WILL BE MADE TO ACCOMMODATE OR ALLOW EXTRA FUNDS
FOR ANY OMISSION WHICH RESULTS FROM A FAILURE TO THOROUGHLY MAKE THE
EXAMINATION.
5. CODES AND PERMITS:
a. ALL MECHANICAL EQUIPMENT, INSTALLATION, ETC., SHALL CONFORM TO THE 2009
INTERNATIONAL MECHANICAL CODE (IMC), 2009 INTERNATIONAL ENERGY
CONSERVATION CODE (IECC) AND ORDINANCES AS INTERPRETED BY THE COUNTY OF
EAGLE BUILDING DEPARTMENT.
b. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS.
c. COPIES OF ALL PERMITS AND INSPECTION REPORTS SHALL BE SUBMITTED TO THE
ARCHITECT.
6. AS-BUILTS:
a. CONTRACTOR SHALL PROVIDE A COMPLETE SET OF AS-BUILT DOCUMENTS WITH ALL
CHANGES NOTED THEREON AT THE COMPLETION OF THE PROJECT AND PRIOR TO FINAL
ACCEPTANCE AND PAYMENT.
7. GUARANTEE:
a. CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE ALL LABOR AND MATERIALS ON
ALL WORK AGAINST DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE
YEAR AFTER COMPLETION.
8. SUBMITTALS:
a. CATALOG INFORMATION AND CUTS OF ALL EQUIPMENT AND DEVICES (WITH ALL
OPTIONS CLEARLY MARKED) SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW (SIX
COPIES OF EACH). ELECTRONIC SUBMITTALS PREFERRED.
9. COORDINATION:
a. THE DRAWINGS ARE DIAGRAMMATIC AND INTENDED TO SHOW SCOPE.
b. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES TO PROVIDE
BEST ARRANGEMENT OF ALL DUCTS, PIPES, CONDUIT, ETC.
10. CUTTING AND PATCHING:
a. ALL CUTTING AND PATCHING REQUIRED OF THE STRUCTURE (NEW OR EXISTING) SHALL
BE PROVIDED UNDER OTHER SECTIONS OF THE WORK.
b. PROVIDE NECESSARY REQUIREMENTS TO THE PROJECT SUPERINTENDENT.
c. X-RAY SLABS PRIOR TO CORING.
11. CLEANUP:
a. UPON COMPLETION OF THE WORK UNDER THIS SECTION, THE CONTRACTOR SHALL
REMOVE ALL SURPLUS MATERIALS, EQUIPMENT AND DEBRIS INCIDENTAL TO THIS WORK
AND LEAVE THE PREMISES CLEAN AND ORDERLY.
12. MECHANICAL IDENTIFICATION
a. EQUIPMENT NAMEPLATES: METAL, WITH DATA ENGRAVED OR STAMPED, FOR
PERMANENT ATTACHMENT ON EQUIPMENT.
13. DUCTWORK:
a. DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH THE 2009 IMC
AND SMACNA STANDARDS.
b. DUCTWORK SHALL BE GALVANIZED STEEL GAUGES TO MEET SMACNA STANDARDS.
DUCTWORK SIZES INDICATED ARE INSIDE TO INSIDE DIMENSIONS.
c. ALL DUCT JOINTS SHALL BE SEALED AIR TIGHT WITH RCD CORP. # 6 MASTIC ADHESIVE
WITH VERSA GRIP OR MESH.
d. ALL FINAL CONNECTIONS TO GRILLES SHALL BE COMPLETED WITH ACOUSTICAL
FLEXIBLE DUCT UNLESS OTHERWISE NOTED ON THE PLANS. MINIMUM LENGTH IS 3',
MAXIMUM LENGTH IS 5'.
e. FLEXIBLE DUCT USED FOR CONDITIONED AIR SHALL BE UL APPROVED, VINYL COATED,
WIRE REINFORCED FIBERGLASS, WITH MAXIMUM THERMAL CONDUCTIVITY OF 0.30
BTU-IN/HR-FT2-°F AND A MAXIMUM LENGTH OF FIVE FEET.
f. DUCTWORK SHALL BE SIZED AT A MAXIMUM VELOCITY OF 1,000 FPM/.08" PRESSURE
DROP PER 100 FEET.
g. EACH MECHANICAL VENTILATION SYSTEM (SUPPLY AND/OR EXHAUST) SHALL BE
EQUIPPED WITH A MEANS OF SHUT-OFF WHEN VENTILATION IS NOT REQUIRED, AND
BACKDRAFT DAMPERS WHICH CAN BE CLOSED ON FAN SHUTDOWN SHALL BE PROVIDED
FOR AIR INTAKES AND/OR DISCHARGES.
h. CLEAN OUT ALL DUCTS PRIOR TO SUPPLY AND RETURN GRILLE INSTALLATION
i. DOUBLE THICKNESS TURNING VANES SHALL BE USED ON ALL DUCT TURNS OF 90°.
14. REFRIGERANT PIPING:
a. REFRIGERANT LINE SETS SHALL BE FURNISHED BY THE CONDENSING UNIT
MANUFACTURER AND BE PRE-INSULATED.
b. REFRIGERANT PIPING CONNECTIONS SHALL BE BRAZED WITH 15% SILL FLOSS. PURGE
PIPING WITH NITROGEN WHILE BRAZING.
c. PROVIDE HANGERS, SUPPORTS AND INSULATION SADDLES AS REQUIRED AND PER ANSI
REQUIREMENTS. PLUMBERS TAPE AND WIRE ARE NOT ACCEPTABLE.
d. REFRIGERANT PIPING INDICATED IS SCHEMATIC ONLY. SIZE PIPING AND DESIGN THE
ACTUAL PIPING LAYOUT, INCLUDING OIL TRAPS, DOUBLE RISERS, SPECIALTIES, AND
PIPE AND TUBE SIZES, TO ENSURE PROPER OPERATION AND COMPLIANCE WITH
WARRANTIES OF CONNECTED EQUIPMENT.
e. EVACUATE THE ENTIRE REFRIGERANT SYSTEM WITH A VACUUM PUMP TO A VACUUM OF
500 MICROMETER FOR A PERIOD OF 12 HOURS PRIOR TO CHARGING.
15. DUCTWORK INSULATION:
a. ALL DUCTWORK SHALL BE INSULATED CONSISTENT WITH THE REQUIREMENTS PER
SECTION 604 OF THE 2009 IMC.
b. INSULATION SHALL BE UL LISTED IN COMPLIANCE WITH A FLAME-SPREAD INDEX NOT
MORE THAN 25 AND SMOKE DEVELOPED INDEX NOT MORE THAN 50, PER THE 2009 IMC.
INSTALLATION SHALL BE IN ACCORDANCE WITH IMC REQUIREMENTS.
c. RECTANGULAR SUPPLY, RETURN & TRANSFER DUCTWORK SHALL BE INTERNALLY LINED
WITH A VAPOR RESISTANT DUCT LINER OF THICKNESSES SPECIFIED BELOW.
d. CONCEALED ROUND, CONCEALED OVAL & OUTDOOR AIR DUCTS SHALL BE EXTERNALLY
WRAPPED WITH FIBERGLASS INSULATION WITH AN EXTERNAL VAPOR BARRIER.
REQUIRED R-VALUES ARE SPECIFIED BELOW.
e. ALL SUPPLY, RETURN & TRANSFER DUCTWORK LOCATED WITHIN THE BUILDING
ENVELOPE SHALL BE INSULATED TO A MINIMUM OF R-4 (1” LINER) UNLESS SPECIFIED
OTHERWISE ON THE PLANS.
f. ALL SUPPLY DUCTWORK LOCATED IN ATTICS OR OTHER UNCONDITIONED SPACES
SHALL BE INSULATED TO A MINIMUM OF R-8 (2” LINER). ALL OTHER DUCTS IN
UNCONDITIONED SPACES SHALL BE INSULATED TO A MINIMUM OF R-6 (1-1/2” LINER).
g. ALL SUPPLY & RETURN DUCTWORK SHALL BE INSULATED TO A MINIMUM OF R-5 (1-1/2”
LINER) WHEN LOCATED IN UNCONDITIONED SPACES AND SHALL BE INSULATED TO A
MINIMUM OF R-8 (2” LINER) AND WEATHERPROOFED WHEN LOCATED OUTSIDE THE
BUILDING.
h. ALL OUTDOOR AIR DUCTS SHALL BE INSULATED TO A MINIMUM OF R-6 WITH A VAPOR
BARRIER.
16. TEMPERATURE CONTROL DEVICES:
a. CONTRACTOR SHALL PROVIDE STAND-ALONE CONTROLS CAPABLE OF MEETING THE
SEQUENCE OF OPERATION DESCRIBED ON SHEET M1.0.
b. THE HVAC SYSTEM SHALL BE PROVIDED WITH 7-DAY PROGRAMMABLE AUTOMATIC
SPACE TEMPERATURE CONTROL DEVICES (THERMOSTATS) AS SHOWN ON THE PLANS.
THE THERMOSTATS SHALL BE CAPABLE OF SCHEDULING OCCUPANCIES AND PROVIDING
SETBACK CAPABILITIES TO MAINTAIN ZONE SETPOINTS DOWN TO 55°F OR UP TO 85°F.
c. CONTROLS SHALL BE CAPABLE OF PROVIDING A DEADBAND OF AT LEAST 5°F BETWEEN
HEATING AND COOLING.
d. THERMOSTATS SHALL HAVE NUMERIC SET POINTS IN °F, ADJUSTABLE SETPOINT STOPS,
AND SHALL BE MOUNTED AT 54" ABOVE FINISHED FLOOR.
e. ALL THERMOSTATS SHALL BE APPROVED BY THE OWNER.
17. GAS APPLIANCE VENTING:
a. ACCEPTABLE VENT MATERIALS, ROUTING, DISTANCE AND TERMINATION LOCATIONS
SHALL COMPLY WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ALL
REQUIREMENTS IN CHAPTER 8 OF THE 2009 IMC.
18. BEFORE STARTING ANY WORK, THE CONTRACTOR FOR THIS SECTION OF THE WORK SHALL
EXAMINE A COMPLETE SET OF DRAWINGS FOR ALL TRADES, INCLUDING ARCHITECTURAL,
STRUCTURAL, HVAC, ELECTRICAL, FIRE PROTECTION AND PLUMBING. DIMENSIONS, SPACE
REQUIREMENTS AND POINTS OF CONNECTION TO ALL EQUIPMENT SHALL BE VERIFIED, AND ANY
MINOR ADJUSTMENTS NECESSARY TO AVOID CONFLICT WITH THE BUILDING STRUCTURE AND
THE WORK OF THE OTHER TRADES SHALL BE MADE. CONTRACTOR SHALL NOTIFY ARCHITECT
IMMEDIATELY IF ANY MAJOR CONFLICTS OCCUR.
19. COORDINATE LOCATIONS OF ALL ROOF AND EXTERIOR WALL OPENINGS WITH ALL RELEVANT
TRADES, AND PROVIDE WATERTIGHT FLASHINGS WHEREVER PENETRATIONS OCCUR. EXACT
LOCATIONS AND SIZES MAY BE DEPENDENT UPON EQUIPMENT SELECTIONS; COORDINATE SIZES
AND LOCATIONS OF ALL OPENINGS WITH APPROPRIATE EQUIPMENT REQUIREMENTS.
20. PERMANENT ACCESS TO EQUIPMENT SHALL BE PROVIDED, AND A MINIMUM OF 30" CLEAR
WORKING SPACE IN FRONT OF ACCESS PANELS TO THE COMPRESSOR, BLOWER ASSEMBLY AND
AIR FILTER SECTION OF THE EQUIPMENT SHALL BE PROVIDED BY GENERAL CONTRACTOR.
21. ALL EQUIPMENT SHALL BE SECURELY FASTENED TO THE BUILDING STRUCTURE WITH CODE
APPROVED VIBRATION ISOLATORS.
22. EACH PIECE OF EQUIPMENT AND ALL SYSTEMS SHALL BE ADJUSTED AND RE-ADJUSTED TO
INSURE PROPER FUNCTION OF ALL CONTROLS, MAINTENANCE OF TEMPERATURE, ADEQUACY OF
FLOWS AND CAPACITIES, ELIMINATION OF NOISE AND VIBRATION, AND SHALL BE LEFT IN PROPER
OPERATING CONDITION.
23. TEST & BALANCING:
a. THE ENTIRE HEATING AND VENTILATING SYSTEM SHALL BE BALANCED BY AN
INDEPENDENT CERTIFIED TEST AND BALANCE COMPANY.
b. 5 COPIES OF THEIR BALANCE REPORTS SHALL BE SUBMITTED TO THE ENGINEER FOR
REVIEW AND APPROVAL. ELECTRONIC DISTRIBUTION PREFERRED.
c. ALL REQUIRED RE-SHEEVING AND ADJUSTING OF EQUIPMENT SHALL BE MADE BY THE
TEST & BALANCE CONTRACTOR.
d. ALL FINAL MEASURED CAPACITIES SHALL BE WITHIN 10% OF THOSE INDICATED ON THE
PLANS.
24. FINAL LOCATION OF GRILLES, REGISTERS & DIFFUSERS SHALL BE PER THE ARCHITECTURAL
PLANS, ELEVATIONS OR AS PER FIELD REQUIREMENTS (UPON ACCEPTANCE BY ARCHITECT).
25. THE GENERAL CONTRACTOR SHALL FURNISH & INSTALL ALL OF THE REQUIRED ACCESS PANELS
IN THE DRYWALL CEILINGS TO GAIN SERVICE ACCESS TO THE EQUIPMENT.
26. ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO THE MANUFACTURER'S INSTALLATION,
OPERATION & MAINTENANCE MANUAL'S RECOMMENDATIONS ESPECIALLY FOR SERVICE
CLEARANCES.
27. FILTERS:
a. SHALL BE UL RATED AND APPROVED.
b. PRESSURE DROPS SHALL NOT EXCEED .10" STATIC PRESSURE.
28. ELECTRICAL CONNECTIONS:
a. UNLESS OTHERWISE INDICATED ALL MAGNETIC MOTOR STARTERS, THERMAL
OVERLOADS, LOW VOLTAGE THERMOSTATS, CONTROL RELAYS, CONTROL
TRANSFORMERS AND SOLENOID VALVES SHALL BY FURNISHED BY THE MECHANICAL
CONTRACTOR.
b. UNLESS OTHERWISE SPECIFIED, ALL MOTORIZED DAMPERS SHALL BE LOW VOLTAGE.
ALL WIRING AND POWER CONNECTIONS SHALL BE PROVIDED BY THE MECHANICAL
CONTRACTOR.
c. PROVIDE MOTORS AND EQUIPMENT FOR ONLY THOSE CURRENT CHARACTERISTICS
INDICATED ON THE DRAWINGS.
d. IT IS THE INTENT OF THIS DIVISION TO REQUIRE A COMPLETE SYSTEM PER THE
CONTRACT DOCUMENTS.
e. COORDINATE ALL EQUIPMENT REQUIRING ELECTRICAL POWER, REGARDLESS OF
VOLTAGE, WITH OTHER TRADES, SO THAT ALL SYSTEMS ARE COMPLETE AND
OPERATIONAL.
f. ALL THREE PHASE MOTORS SHALL BE PROVIDED WITH PHASE LOSS PROTECTION.
g. ALL SINGLE AND THREE PHASE MOTORS, STARTERS AND DISCONNECTS PROVIDED BY
MECHANICAL CONTRACTOR AND WIRED BY THE ELECTRICAL CONTRACTOR.
29. TEMPORARY HEATING DURING CONSTRUCTION:
a. MECHANICAL EQUIPMENT SHALL NOT BE UTILIZED FOR TEMPORARY HEATING.
b. GAS FIRED TEMPORARY HEAT SHALL BE PROVIDED BY THE GENERAL CONTRACTOR.
of
ww
w.a
ec-va
il.co
m
aP
O B
ox 8
48
9, 4
08
01
U
S H
wy 6
&
2
4, S
te
2
14
, A
vo
n, C
olo
ra
do
, 8
16
20
Mechanical, E
lectrical &
Lighting D
esign S
ervices
Architectural E
ngineering C
onsultants
Telephone: 970-748-8520ce
Drawn By: Checked By:
DATE: ISSUE:
07-02-15BID SET
AEC PROJECT #:
EA
GLE
C
OU
NT
Y A
IR
PO
RT
AD
MIN
IS
TR
AT
IO
N
OF
FIC
E R
EM
OD
EL
GY
PS
UM
, C
O
15050
An O
ffice w
ith LE
ED
™ A
ccredited P
rofessionals
F
2
F
1
GENERAL NOTES:
1. ALL DUCTWORK DIMENSIONS ARE SHOWN INSIDE TO INSIDE.
2. ALL INTERIOR SUPPLY AND RETURN DUCTWORK SHALL INCLUDE 1" LINER
UNLESS OTHERWISE NOTED. ALL OUTSIDE AIR INTAKE AND ROUND
DUCTWORK SHALL BE WRAPPED WITH 1.5" THICK INSULATION UNLESS
OTHERWISE NOTED.
3. ALL FINAL DUCTWORK CONNECTIONS TO SUPPLY GRILLES (OR PLENUMS)
SHALL BE COMPLETED WITH ACOUSTICAL FLEXIBLE DUCT UNLESS
OTHERWISE NOTED AND A MAXIMUM LENGTH OF FIVE FEET.
4. ALL ROUND DUCT CONNECTIONS TO ROUND DUCTWORK SHALL BE
CONICAL TEES.
5. ALL SQUARE 90 DEGREE ELBOWS SHALL HAVE TURNING VANES.
6. ALL DUCTWORK SHALL BE RUN TIGHT TO UNDERSIDE OF STRUCTURE
WHERE IT EXISTS UNLESS OTHERWISE NOTED.
7. ALL DUCTWORK PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL
INCLUDE FIRE DAMPERS RATED TO MATCH THAT OF THE ASSEMBLY.
8. ALL SUPPLY GRILLES SHALL HAVE AN BALANCING DAMPER UNLESS
OTHERWISE NOTED. IF THE DAMPER IS LOCATED IN AN INACCESSIBLE
LOCATION, CABLE-STYLE DAMPERS (ROTOTWIST OR EQUIVALENT) SHALL
BE INSTALLED AND SHALL BE ADJUSTABLE FROM THE GRILLE FACE.
9. COORDINATE ALL ACCESS PANEL LOCATIONS WITH THE ARCHITECT.
SHEET DETAIL NOTES:
ROUTE TO OUTSIDE AIR TO EXISTING OUTSIDE AIR DUCT IN SPACE.
CAP EXISTING OUTSIDE AIR DUCT WHERE DUCT IS DISCONNECTED
FROM EXISTING EVAPORATIVE COOLER.
TERMINATE FURNACE CONDENSATE DRAINS INDIRECTLY TO NEW
FUNNEL BELOW SINK. CONNECT FUNNEL TO EXISTING WASTE PIPE
SERVING SINK.
TERMINATE WITH WALL TERMINATION KIT (BAYVENT200B). INSTALL
PER MANUFACTURER REQUIREMENTS. MAINTAIN 3' CLEARANCE TO
ANY OPERABLE OPENINGS INTO THE BUILDING AND 10' FROM ANY
MECHANICAL AIR INTAKES. PAINT TERMINATION TO MATCH WALL
COLOR. ENSURE PAINT DOES NOT IMPEDED AIRFLOW.
ROUTE 1" G TO GAS METER. EXISTING GAS PIPING MAY BE REUSED IF
IT IS AT LEAST 1". IF TOTAL DISTANCE EXCEEDS 200', CONTACT
ENGINEER PRIOR TO INSTALLING. ANY ABANDONED GAS PIPE SHALL
BE REMOVED. CONFIRM GAS METER CAN HANDLE AN ADDITIONAL
LOAD OF 50 MBH.
PROVIDE REQUIRED EQUIPMENT CLEARANCES.
ROUTE TO EXISTING GRILLE IN OBSERVATION TOWER FLOOR AND
BALANCE TO 50 CFM (ADJ.).
ROUTE REFRIGERANT PIPING FROM CONDENSING UNIT TO
ASSOCIATED COOLING COIL. SIZE PIPING ACCORDING TO
MANUFACTURER'S REQUIREMENTS.
1
2
12"Ø
12"Ø
10"Ø
8"Ø
8"Ø
6"Ø
6"Ø
6"Ø 9"Ø
10"Ø
12"Ø
6"Ø
8"Ø
6"Ø
8"Ø
8"Ø
6"Ø
E
255-S
24x24
B
255-R
24x24
E
765-R
24x24
E
385-R
24x24
E
380-S
24x24
A
125-S
24x24
E
100-S
24x24
A
105-S
24x24
A
80-S
24x24
A
50-S
24x24
B
140-R
24x24
E
195-S
24x24
E
120-S
24x24
B
100-R
24x24
B
125-R
24x24
B
215-R
24x24
CU
1
CU
2
10"Ø
8"Ø
1
1
T
T
F-1
F-2
FURNACE IN THIS AREA SHALL BE LOWERED
BELOW NEW FLOOR AND MOVED NORTH.
REROUTE FLUE UP AS SHOWN AND ALONG
ROOF TO EXISTING WALL PENETRATION.
SHORTEN SUPPLY DUCT AS NECESSARY.
EF
1
6"Ø
TERMINATE WITH 6" WALL CAP
(SEIHO SX 6 OR EQUIVALENT)
6"Ø12"Ø
12"Ø
10"Ø
12"Ø
16"Ø
12"Ø
16"Ø
10"Ø
14"Ø
6"Ø
M
M
MD
1
MD
2
M
M
MD
3
MD
4
B
70-R
24x24
3
3
3
2" FLUE & COMBUSTION AIR
2" FLUE & COMBUSTION AIR
2" COMBUSTION AIR & 2" VENT,
PROVIDE CONCENTRIC DIRECT
VENT (BAYVENT200B)
COOLING COIL
REFRIGERANT CONNECTION
TO OUTDOOR AIR
CONDENSING UNIT
CONDENSATE ON THE
BOTTOM TO
CONDENSATE AUX. DRAIN
PAN
CONDENSATE DRAIN TO
CONDENSATE AUX. DRAIN PAN
GAS FURNACE
1
2
" GAS CONNECTION
RETURN AIR
SUPPLY AIR
GAS FURNACE HORIZONTAL FLOW DETAIL
NO SCALE
NEOPRENE MOUNTING
BUSHING
ANCHOR TO BAR JOIST
S
FLUID DETECTION SENSOR
AUXILIARY DRAIN PAN
ROUTE DRAIN DOWN INTO AND THRU WALL. DISCHARGE INDIRECTLY
INTO WASTE LINE.
INSULATED RIGID DUCT
AIR
F
LO
W
CLAMP
MANUAL DAMPER,
HANDLE, & LOCK NUT
WORM DRIVE S.S.
Ø TWIST-IN FITTING W/
INSULATED RIGID DUCT
AIR
F
LO
W
CLAMP
MANUAL DAMPER,
HANDLE, & LOCK NUT
WORM DRIVE S.S.
Ø TWIST-IN FITTING W/
ROUND DUCT TAKE-OFF DETAIL
NO SCALE
EXISTING EXHAUST
TO REMAIN
EXISTING EXHAUST
TO REMAIN
TYPICAL LOW PRESSURE
GAS CONNECTION DETAIL
NO SCALE
GAS SHUT
OFF VALVE
TYP.
LOW
PRESSURE
GAS LINE
6" MIN.
DRIP LEG
MECHANICAL
EQUIPMENT
NOTE:ALL EXISTING SUPPLY AND RETURN DUCTWORK SHALL
BE REMOVED. EXISTING EVAPORATIVE COOLER AND FURNACE
SHALL BE REMOVED. EXISTING OUTSIDE AIR DUCT CURRENTLY
SERVING EXISTING EVAPORATIVE COOLER SHALL REMAIN AND
SUPPLY OUTSIDE AIR TO THE NEW FURNACES AS SHOWN.
4
4
2
3
4
" G
3
4
" G
5
5
5
5
5
6"Ø
6
6
CC
2
CC
1
7
7
7
7
7
of
ww
w.a
ec-va
il.co
m
aP
O B
ox 8
48
9, 4
08
01
U
S H
wy 6
&
2
4, S
te
2
14
, A
vo
n, C
olo
ra
do
, 8
16
20
Mechanical, E
lectrical &
Lighting D
esign S
ervices
Architectural E
ngineering C
onsultants
Telephone: 970-748-8520ce
Drawn By: Checked By:
DATE: ISSUE:
07-02-15BID SET
AEC PROJECT #:
EA
GLE
C
OU
NT
Y A
IR
PO
RT
AD
MIN
IS
TR
AT
IO
N
OF
FIC
E R
EM
OD
EL
GY
PS
UM
, C
O
15050
An O
ffice w
ith LE
ED
™ A
ccredited P
rofessionals
NORTH
HVAC PLAN
SCALE: 1/4" = 1'0"
equipment, etc. furnish by mechanical - refer to both electrical and
electrical apparatus as shown on single line diagram and
and mechanical drawing for scope and work and additinal infor-
Complete connection of HVAC/Plumbing motor(s), water heater(s),
Fire alarm system will be by electrical contractor.
Complete provision, installation and connection of lighting fixtures,
exit signs and lamps as specified and as shown on drawings.
Complete branch circuit wiring required for the connection of
emergency lighting and exit signs to existing emergency stand
Complete feeder(s) installation as required for new and/or
devices, new control devices, etc. for a complete lighting and
including new panelboards, new conduits, new wires, new wiring
Complete wiring system for new lighting and power as shown,
contract. Electrical work shall include, but not limited to, these major
as indicated on drawing and as specified, as necessary to complete the
SCOPE: Furnish all materials and labor required to execute this work
2.
3.
4.
6.
5. Provide grounding and bonding Facilities.
Complete all electrical demolition as required.
mation.
A.
ELECTRICAL SPECIFICATIONS
1.
drawings.
by power system.
and power system.
b.
a.
items:
A. Contractor shall submit shop drawings for engineer review and approval.
MC cable permitted per local codes. Run hard pipe from panel to local
Lighting fixtures.
Shop drawing submittal shall include:
Panelboard(s).
CONDUIT AND WIRE:
B.
13.
A.
B.
2.
1.
and contractor shall have written approvals from building owner prior
Core drilling and patching of existing building structure required for
Operating, Maintenance and identification instructions manuals, if
electrical work. Core drilling shall follow Building Standard procedures
Applicable codes: National Electric Code (2014)
PERMITS AND FEES: Obtain and pay for all necessary permits, inspec-
tions, examinations and fees or charges necessary for execution and
and to the requirements of Federal, State or other City agencies
Town of Gypsum Electrical Code, pertinent NFPA publications
Conform to the prevailing edition and amendments thereto of the
SHOP DRAWINGS AND SUBMITTAL:
to start of any work.
Test of entire system and work.
REGULATIONS AND CODES:
having jurisdiction.
completion of electrical work.
12.
11.
A.
7.
9.
8.
10.
any.
THE NEW FIRE LIFE SAFETY EQUIPMENT REQUIRED FOR THIS CONTRACT
SHALL BE BY THE SAME MANUFACTURER. ALL FIRE LIFE SAFETY SYSTEM
COMPONENT, EQUIPMENT, DEVICES, ETC. LESS WIRING PROVIDED IN THIS
CONTRACT SHALL BE COMPATIBLE FOR SAID ALARM EQUIPMENT USED AT
THE SITE, AND BE BOTH CFM AND U.L. LISTED FOR SAME.
CONTRACTOR SHALL SUBMIT UNIT PRICES ON F.A. EQUIPMENT AND DEVICES
PRIOR TO BID, CONTRACTOR SHALL VERIFY NEW FIRE LIFE
SAFETY INSTALLATION AND INCLUDE ALL LABOR AND MATERIAL REQUIRED
FOR A COMPLETE AND OPERABLE LIFE SAFETY AND SMOKE CONTROL
SUPPLY & INSTALL NEW EQUIPMENT AND MODIFICATIONS TO EXISTING FIRE ALARM
PROVIDE ALL COSTS FOR LABOR, DESIGN, ENGINEERING,
SYSTEM TO PROVIDE A COMPLETE FIRE ALARM SYSTEM TO MEET LOCAL CODES.
ALL NEW FIRE ALARM EQUIPMENT, DEVICES, WIRING, ETC. REQUIRED AND
WHICH ARE INSTALLED FOR THE FACILITY SHALL MEET
LATEST EDITION OF THE NFPA FIRE LIFE SAFETY CODES AND SHALL MEET
ALL CITY AND STATE FIRE MARSHALL REQUIREMENTS.
THE FIRE ALARM SYSTEM SCOPE OF WORK SHALL INCLUDE, BUT NOT
NECESSARILY BE LIMITED TO THE FOLLOWING:
CALCULATIONS, SHOP DRAWING, ETC. INCLUDING SUBMISSION OF FINAL
FIRE ALARM LIFE SAFETY DRAWING TO THE AUTHORITY HAVING
JURISDICTION FOR REVIEW AND APPROVAL.
PROVIDE ALL COSTS FOR LABOR, MATERIAL, INSTALLATION,
CONNECTION AND EXECUTION OF FIRE LIFE SAFETY ALARM EQUIPMENT,
DEVICES, CONDUIT/WIRING SYSTEM, ETC. AS REQUIRED DUE TO THE
CONSTRUCTION OF THIS FACILITY.
IN THEIR BID.
SYSTEM(S).
3.
2.
B.
A.
1.
ALARM DEVICE LOCATIONS & QUANTITIES PRIOR TO FINAL ROUGHIN.
WITH THE AUTHORITY HAVING JURISDICTION TO DETERMINE FINAL FIRE
AND ARE DIAGRAMMATIC ONLY. THE CONTRACTOR SHALL WALK THROUGH
DRAWINGS HAVE BEEN DEVELOPED FOR BIDDING AND PRICING PURPOSES
4.
WHEN PERMITTED BY THE AUTHORITY HAVING JURISDICTION, COORDINATE WITH
PAINTER TO FINISH THE CEILING MOUNTED SMOKE DETECTORS TO MATCH
RESPECTIVE CEILINGS. REFER TO MANUFACTURER'S INSTRUCTIONS
REGARDING ADDITIONAL FINISHES TO THE SPECIFIC PRODUCT.
5.
N. All cabling shall be bundled and properly secured and terminated.
warranty period shall begin at the point of system acceptance or beneficial
system during this warranty period at no additional cost to the owner. The
free of defects of workmanship or products and will inspect and repair the
from the date of project completion. The contractor warrants the system to be
O. The warranty set forth for this system shall consist of a full three (3) years
use, whichever comes later.
Coordinate numbering scheme with owner.
enclosed within cable trays, raceways or conduit, as specified.
engineer. Cabling shall be in the wall, above the ceiling or where exposed,
M. No exposed wiring will be accepted unless approved in writing by the
Care must be taken to ensure cables are not kinked, bent beyond limit,
including NEC, EIA/TIA 568,569 and 606, and federal, state and local codes.
familiar and install in accordance with all applicable codes and standards,
L. All cable hangers shall be no more than 48" apart. Contractor shall be
Cables are to be kept a minimum of 6" from power lines, electric motors,
K. Cable bends shall be no less than eight times the cable diameter or 1.00".
termination. No more than .5 inches of exposed untwisted pairs shall be
the extent in which each twisted pair is unraveled at the point of its physical
J. All connections of twisted wiring shall be made in such a way as to minimize
length of the run. Splices and bridge taps with cabling are strictly prohibited.
Cabling shall be free from tension at both ends, as well as through out the
I. All wiring shall be protected from moving mechanical or physical contacts.
cable runs exceeding 90 meters and provide solution to meet the 90 meter
H. Route cables so as not to exceed 90 meters in length. Bidder will identify any
the case of "hard" drywall ceilings, adequate support shall be accomplished
independent hangers. Cable "draped" across ceiling tiles is unacceptable. In
G. All cable above the ceiling must be tied and properly supported with
F. Provide plenum rated cable when required by article NEC 300-22.
overloaded, over-cinched, crushed, improperly untwisted, etc.
fluorescent fixtures or heat generating devices.
present at these locations.
Wiring is to be run in cable tray and conduit where specified.
requirement.
where reasonably possible.
patch panel location, and each wall/floor faceplate that has wiring installed.
E. All cables will be labeled with self-laminating labels at each cable end, at each
jacks, match faceplates to power, color coded for voice and data, match to
modular RJ-45, 8 pin, 8 conductor, Hubbell, Leviton, or lucent or equivalent
C. The terminations at the station locations must be Category 6, T568B (AT&T)
B. Data cable will be colored blue. Voice cable will be colored white.
manufacturers include: Berk-Tek, Belden, Lucent or equivalent.
500 Mhz or better category 6, 4 pair UTP as applicable. Acceptable
A. The cabling for voice and data must be continuous, home run, non-spliced,
D. Wall mounted patch panels will be provided.
cable. Outlets will be securely held in place.
B. Cat 6 Wiring Requirements
6.
A. General Requirements
C. Fire Life Safety Scope of Work
& General Conditions
PROVIDE PLENUM RATED CABLE WHEN REQUIRED BY ARTICLE NEC 300-22.
14.
decora style. Finish per owner or architect.
Convenience receptacles will be 20 amp, commercial grade
Light switches will be 20 amp, commercial grade,B.
ELECTRICAL DEVICES
A.
decora style. Finish per owner or architect.
Provide decora style, finish per owner or architect.
Dimming switches will be a minimum of 600w or as noted.C.
15.
Support all electrical equipment independent of accessible ceilings as
required by NEC.
SUPPORT
A.
All mounting heights will conform to ADA guidelines. Typical receptacleD.
heights will be +18"AFF and switch heights will be +46"AFF
unless noted otherwise.
16.
At fire rated wall space electrical boxes at opposite sides of the wall
no less than 24" horizontal distance.
ELECTRICAL BOXES
A.
When phone, TV & power receptacles are shown on plan next to each other.
Locate respective receptacles next to each other on site with no more
B.
than 1" seperating cover plates.
Provide GFI type receptacles at kitchens, bathrooms,
garages, exterior etc. as required by code.
E.
ACCEPTABLE FIRE ALARM SYSTEM MANUFACTURERS ARE SIMPLEX, NOTIFIER,
SILENT KNIGHT & FIRELITE. FIRE ALARM SYSTEMS MUST HAVE PARTS AND SERVICE
AVAILABLE WITHIN 24 HOURS.
7.
8.
H/P HEAT/PHOTOELECTRIC SMOKE DETECTOR
ELECTRICAL LEGEND
(NOT ALL SYMBOLS REQUIRED FOR THIS PROJECT)
RECESSED OR SURFACE DOWNLIGHT
WALL MOUNTED LIGHT FIXTURE
RECESSED FLUOR. LIGHT FIXTURE
SURFACE FLUOR. LIGHT FIXTURE
Aa
Aa
FIXTURE DESIGNATIONS:
UPPER CASE - FIXTURE TYPE
LOWER CASE - SWITCH DESIGNATION
SHADING ON FIXTURE INDICATES EMERG. BATTERY BACKUP
FLUORESCENT STRIP FIXTURE
TRACK LIGHT AS NOTED OR SCHEDULED
WALL WASHER
POLE-MOUNTED FIXTURE
POST (BOLLARD) FIXTURE
CEILING OR WALL MOUNTED EXIT LIGHT
EMERGENCY BATTERY LIGHTS
DUPLEX RECEPTACLE @ 18" UNLESS NOTED
DOUBLE DUPLEX RECEPTACLE @ 18" UNLESS NOTED
SPECIAL OUTLET AS NOTED
FLUSH FLOOR DUPLEX RECEPTACLE
DUPLEX RECEPTACLE HALF-SWITCHED @ 18" UNLESS NOTED
TELE-POWER POLE
JUNCTION BOX IN FLOOR, CEILING OR IN WALL
MULTI-OUTLET PLUG STRIP
COMPUTER/TELEPHONE OUTLET IN FLOOR OR WALL
CONDUIT RUN CONCEALED IN WALL OR ABOVE CEILING
TELEPHONE BACKBOARD
CIRCUIT HOMERUN
CONDUIT RUN BELOW FLOOR OR GRADE
CONDUIT STUB-UP - CAP & MARK
LIGHT SWITCH AT 46" UNLESS NOTED
SUBSCRIPTS:
2 = 2-POLE SWITCH
3 = 3-WAY SWITCH
4 = 4-WAY SWITCH
K = KEY-OPERATED SWITCH
TO = THERMAL OVERLOAD SWITCH
P = SWITCH WITH PILOT LIGHT
DIMMER SWITCH W/ WATTAGE
MAGNETIC MOTOR STARTER
DISCONNECT SWITCH
TRANSFORMER
GROUND
PUSHBUTTON CONTROL STATION
PHOTOELECTRIC CELL
TIME SWITCH
THERMOSTAT AT 60" UNLESS NOTED
DIVISION 15 EQUIPMENT
CIRCUIT BREAKER
MOTOR OUTLET
AUTOMATIC TRANSFER SWITCH
FOOD SERVICE EQUIPMENT
PC
TS
T
ABBREVIATIONS
- ABOVE COUNTERAC
AFF - ABOVE FINISHED FLOOR
- ABOVE FINISHED GRADEAFG
- ALUMINUMAL
- EMERGENCYEM
- GROUNDGND
- GROUND FAULT INTERRUPTERGFI
NIC - NOT IN CONTRACT
NL - NIGHT LIGHT
NTS - NOT TO SCALE
UG - UNDERGROUND
WP - WEATHER PROOF
XFMR - TRANSFORMER
+18" - MOUNTING HEIGHT TO CENTERLINE
OF DEVICE AFF OR AFG
FIRE ALARM SYSTEM
FIRE ALARM CONTROL PANEL
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM PULL STATION
ALARM HORN OR SPEAKER
COMBINATION HORN/STROBE OR SPEAKER/STROBE
THERMAL HEAT DETECTORH
SMOKE/IONIZATION DETECTORI
PHOTOELECTRIC SMOKE DETECTORP
DUCT DETECTOR
SPRINKLER SYSTEM FLOW SWITCH
SPRINKLER SYSTEM TAMPER SWITCH
STROBE
SMOKE/FIRE DAMPER CONNECTION
REMOTE INDICATOR LIGHT
COMMUNICATION SYSTEM
SPEAKER IN CEILING OR WALL
VOLUME CONTROL AT 60" UNLESS NOTED
MICROPHONE OUTLET IN FLOOR BOX OR WALL
CALL-IN SWITCH
PROGRAM BELL
INTERCOM
CLOCK
AMPLIFIER
TELEVISION OUTLET
CONTACT DOOR SWITCH IN JAMB OR HINGE
SECURITY SYSTEM
KEY-OPERATED ACCESS SWITCH
SURVEILLANCE CAMERA
DISTRIBUTION EQUIPMENT SYMBOLS
DISCONNECT SWITCH
FUSES
CIRCUIT BREAKER
CURRENT TRANSFORMER
TRANSFORMER
METER
CU - COPPER
STEP LIGHT
FACP
M = MOTION-OPERATED SWITCH
POP-UP RECEPTACLE
- ELECTRICAL CONTRACTOREC
- AUTHORITY HAVING JURISDICTIONAHJ
- MECHANICAL CONTRACTORMC
- PLUMBING CONTRACTORPC
UTP - UNSHIELDED TWISTED PAIR
- GENERAL CONTRACTORGC
- REFERENCEREF
junction box, and run MC cable from junction box to device.
1. WALL ASSEMBLY - THE 1, 2, 3 OR 4 HR FIRE-RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY
SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL
U300 OR U400 SERIES WALL OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND
SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES:
A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS (MAX 2 HR FIRE RATED
ASSEMBLIES) OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. (51 BY 102
MM) LUMBER SPACED 16 IN. (406 MM) OC WITH NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER END PLATES
AND CROSS BRACES. STEEL STUDS TO BE MIN 3-5/8 IN. (92 MM) WIDE BY 1-3/8 IN. (35 MM) DEEP
CHANNELS SPACED MAX 24 IN. (610 MM) OC.
B. GYPSUM BOARD* - NOM 1/2 OR 5/8 IN. (13 OR 16 MM) THICK, 4 FT. (122 CM) WIDE WITH SQUARE
OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER
TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES
DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX DIAM OF OPENING IS 26 IN. (660 MM).
2. THROUGH PENETRANT - ONE CONDUIT INSTALLED EITHER CONCENTRICALLY OR
ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN PIPE, CONDUIT OR
TUBING AND PERIPHERY OF OPENING SHALL BE MIN OF 0 IN. (0 MM) (POINT CONTACT) TO MAX 2 IN. (51
MM). PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY.
THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED:
A. CONDUIT - NOM 6 IN. (152 MM) DIAM (OR SMALLER) STEEL CONDUIT OR NOM 4 IN. (102 MM) DIAM
(OR SMALLER) STEEL ELECTRICAL METALLIC TUBING
3. FILL,VOID OR CAVITY MATERIAL* - CAULK OR SEALANT - MIN 5/8. 1-1/4,1-7/8 AND 2-1/2 IN.
(16, 32, 48 AND 64 MM) THICKNESS OF CAULK FOR 1, 2, 3 AND 4 HR RATED ASSEMBLIES,
RESPECTIVELY, APPLIED WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF WALL. MIN 1/4 IN. (6 MM)
DIAM BEAD OF CAULK APPLIED TO GYPSUM BOARD/PENETRANT INTERFACE AT POINT CONTACT
LOCATION ON BOTH SIDES OF WALL.
THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE HOURLY FIRE RATING
OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS SHOWN IN THE FOLLOWING TABLE.
THE HOURLY T RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE TYPE OR SIZE OF THE
PIPE OR CONDUIT AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED,
AS TABULATED TO THE LEFT.
3M COMPANY - CP 25WB+ CAULK OR FB-3000 WT SEALANT,
*BEARING THE UL CLASSIFICATION MARKING
PENETRATION THROUGH A FIRE-RATED WALL
T
18
"(1
'6
")
46
"(3
'1
0")
48
"(4
'-0
")80
"(6
'8
")
TYPICAL DEVICE
MOUNTING HEIGHTS
MAIN CIRCUIT BREAKER &
BRANCH CIRCUIT BREAKERS
MAXIMUM MOUNTING HEIGHT
IS 79", MINIMUM IS 18".
THE ELECTRICAL CONTRACTOR WILL PROVIDE A WALK THROUGH WITH THE
OWNER/ARCHITECT PRIOR TO FINAL ROUGHIN AS FOLLOWS:
CONFIRM ALL LOCATIONS FOR LIGHT SWITCHES; ADD THREE WAYS IF
FOUND NECESSARY.
REVIEW RECEPTACLE LOCATIONS; MOVE AS REQUIRED. PROVIDE
UNIT PRICING IF ADDITIONAL RECEPTACLES ARE REQUIRED.
REVIEW RECEPTACLE LOCATIONS AT COUNTERS AND CONFIRM IF
THOSE RECEPTACLES SHOULD BE ABOVE COUNTER OR BELOW. MOVE
AS REQUIRED.
IN GENERAL CONFIRM POWER AND LIGHTING REQUIREMENTS. THE
ELECTRICIAN SHOULD BE PREPARED TO REWORK SOME DEVICE LOCATIONS.
SIGNIFICANT REWORK SHOULD BE FLAGGED AND UNIT PRICING PROVIDED
AND WRITTEN AUTHORIZATION FOR ADDITIONAL COSTS APPROVED PRIOR
TO PROCEEDING.
+80"AFF
P
+80:AFF
TELEPHONE ONE-
LINE DIAGRAM
TELEPHONE/
COMPUTER ROUGHIN
FIRE ALARM CONTROL PANEL
H
P
NO SCALE
NOTES:
1. ALL WIRE WILL BE SHIELDED. WIRING PER MANUFACTURERS REQUIREMENTS.
2. REFERENCE FLOOR PLANS FOR QUANTITIES.
3. PROVIDE PLENUM RATED WIRE WHERE REQUIRED.
4. FIRE ALARM SYSTEM IS SHOWN AS A DESIGN BUILD SYSTEM. FINAL DESIGN AND
DEVICE QUANTITIES ARE BY THE ELECTRICAL CONTRACTOR.
CONDUCTOR SIZES AND TYPES: For sizes #1/0 AWG and larger, use
coppper THW or aluminum XHHW. For sizes #1 AWG and smaller, use only
copper wire with 600V insulation, types TW, THHN, or THW - stranded in
sizes #8 and larger, solid in sizes #10 and smaller. Control wiring shall be #14,
stranded. Use type THHN for wires entering or passing through fluorescent
lighting fixtures. All motors shall be wired with copper conductors only.
UNO - UNLESS NOTED OTHERWISE
EXTERIOR
HORN
MIN.
#14AWG
FAN
SHUT
OFF
.23A 24VDC
ADA HORN/
STROBE MAX.
15 PER CIRCUIT
ROUTE WIRE AT CEILING PARALLEL OR
PERPENDICULAR TO STRUCTURE. SECURE
TO STRUCTURE AT 4' INTERVALS OR LESS.
STUB UP TO ABOVE
ACCESSIBLE CEILNG
STRUCTURED CABLE
DISTRIBUTION PANEL
(2#CAT 6) 3/4"C
PLENUM RATED WIRE
WHEN REQUIRED
(2) RJ-45 IN
SINGLE
GANG BOX
COLD WATER PIPE
NOT TO SCALE
NOTES:
1. HEIGHTS SHOWN ARE TYPICAL TO CENTERLINE OF BOX
UNLESS NOTED OTHERWISE.
2. DEVICES ABOVE DOORS SHALL BE CENTERED BETWEEN TOP
OF DOOR TRIM AND CEILING LINE.
3. MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONS
AND NOTED ON ELECTRICAL FLOOR PLANS SHALL GOVERN
OVER THOSE SHOWN ABOVE.
4. FOR CEILING HEIGHTS HIGHER THAN 7'2", INSTALL FIRE ALARM
NOTIFICATION AUDIO AND VISUAL APPLIANCES AT 80"AFF
OTHERWISE INSTALL AT 6" BELOW CEILING.
5. MOUNTING HEIGHTS PER IBC 2009 AND ADA CODES
MAIN TELE/DATA
ROOM
(PULLWIRE)4"C
120V, 1P
BATTERY
BACKUP
DIALER
TELEPHONE
NOT TO SCALE
NO SCALE
FINISHED FLOOR
TYPICAL 8'0" CEILING
Provide tamper proof receptacles at all residential
areas as required by code.
F.
DEMOLITION NOTES:
1. THE ELECTRICAL CONTRACTOR SHALL REMOVE ALL WIRING DEVICES,
LIGHT FIXTURES, ETC., WHICH ARE INDICATED TO BE REMOVED. IN
GENERAL, SYMBOLS WHICH ARE SHOWN ON DEMOLITION PLANS
INDICATE DEVICES WHICH ARE EXISTING, AND WHICH ARE TO REMAIN.
SYMBOLS WHICH ARE SHOWN ON THE PLANS AND WHICH HAVE AN (R)
ADJACENT, INDICATE DEVICES TO BE REMOVED. SYMBOLS WHICH ARE
SHOWN ON THE PLANS AND WHICH HAVE AN (E) ADJACENT, INDICATE
DEVICES THAT ARE EXISTING AND SHALL REMAIN, RE-WORK MY BE
NECESSARY TO CONNECT TO NEW CIRCUIT OR PROVIDE NEW
CONNECTION AS SHOWN IN NEW POWER PLANS. SEE RESPECTIVE
LIGHTING OR POWER PLANS. DEVICES WHICH ARE TO BE REMOVED MAY
REQUIRE REWORKING CONDUIT AND WIRING IN ORDER TO MAINTAIN
SERVICE TO OTHER DEVICES. REMOVED DEVICES SHALL BE PATCHED
OVER AND PAINTED TO MATCH, INCLUDE ALTERNATE PRICING TO
PROVIDE BLANK FACEPLATES INSTEAD OF PATCHING
2. WHERE REMODELING INTERFERES WITH CIRCUITS IN AREAS WHICH ARE
OTHERWISE UNDISTURBED, CIRCUITS SHALL BE REWORKED AS
REQUIRED.
3. EXISTING DEVICES AND CIRCUITING WHICH ARE SHOWN ARE INDICATED
ONLY FOR INFORMATIONAL PURPOSES. THE ELECTRICAL CONTRACTOR
SHALL VISIT THE SITE AND SHALL VERIFY CONDITIONS AS THEY EXIST
AND SHALL REMOVE, RELOCATE AND/OR REWORK ANY ELECTRICAL
EQUIPMENT OR CIRCUITS AFFECTED (WHETHER INDICATED OR NOT) DUE
TO REMOVAL OR REWORKING OF EXISTING WALLS, CEILINGS, ETC. THE
ELECTRICAL CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH ALL WORK
TO BE DONE BY OTHER TRADES BY STUDYING THE ARCHITECTURAL,
STRUCTURAL, MECHANICAL, AND PLUMBING DRAWINGS.
4. COORDINATE THE ROUTING OF ALL CONDUITS WITH THE MECHANICAL
AND PLUMBING CONTRACTORS IN ORDER TO AVOID CONFLICTS WITH
DUCTS, PIPES, ETC.
5. ALL EQUIPMENT, LUMINAIRES, DEVICES, ETC., WHICH ARE REMOVED,
SHALL BE DELIVERED TO THE OWNER FOR DISPOSITION. ALL ITEMS
WHICH ARE REMOVED AND NOT WANTED BY THE OWNER AND WHICH
ARE NOT REUSED SHALL BECOME THE PROPERTY OF THE CONTRACTOR
AND SHALL BE REMOVED FROM THE SITE.
6. THE COST OF CUTTING AND PATCHING NECESSARY FOR THE
INSTALLATION OR REMOVAL OF ELECTRICAL WORK SHALL BE INCLUDED
IN THE ELECTRICAL CONTRACT. COORDINATE WITH THE GENERAL
CONTRACTOR.
7. THE ELECTRICAL CONTRACTOR SHALL REMOVE AND REPLACE LIGHTING
FIXTURES, REWORK, RELOCATE OR REPLACE CONDUIT AND WIRING, AND
DO OTHER WORK REQUIRED BY THE INSTALLATION OF NEW DUCTWORK,
PIPING, ETC., ABOVE EXISTING CEILING. COORDINATE WITH OTHER
CONTRACTORS AND VERIFY THE EXTENT OF THE WORK.
8. ALL LIGHT FIXTURES WHICH ARE INDICATED TO BE RELOCATED SHALL BE
CLEANED, RELAMPED WITH F40WW LAMPS AND RELOCATED IN LOCATION
INDICATED ON ELECTRICAL DRAWINGS.
9. THE ELECTRICAL CONTRACTOR SHALL OBTAIN WRITTEN AUTHORIZATION
FROM THE OWNER (30) CALENDAR DAYS PRIOR TO ANY OUTAGE.
of
ww
w.aec-vail.com
M
echa
nica
l, E
le
ctrica
l &
L
igh
ting
D
esign
S
ervice
s
Architectural E
ngineering C
onsultants
Tele
pho
ne: 97
0-74
8-8
520
Drawn By: Checked By:
DATE: ISSUE:
07-02-15BID SET
AEC PROJECT #:
EA
GLE
C
OU
NT
Y A
IR
PO
RT
AD
MIN
IS
TR
AT
IO
N
OF
FIC
E R
EM
OD
EL
GY
PS
UM
, C
O
15050
An Office with LEED™ Accredited Professionals
T
UTILITY
TRANSFORMER
PAD MOUNTED
NO SCALE
NOTE: PROVIDE SHORT CIRCUIT BRACING TO MEET REQUIREMENTS NOTED
AT ONE-LINE, NOTED AS "AIC AVAILABLE". SERIES RATED COMBINATION
ACCEPTABLE, SUBMIT MANUFACTURER'S SERIES RATINGS WITH SHOP
DRAWING REVIEW.
PANEL R1
(1-42)
PANEL R1
(43-84)
100/3
(4 #1 CU, 1 #4 CUG) 2"C
OR (4 #1/0 MCM AL, 1 #2 ALG) 3"C
PANEL
R1A
100/3
PANEL
R1B
HOLY CROSS METER# 95920
MAXIMUM DEMAND OF 37.6KW
MEASURED ON JAN 2014.
NEW WORK
IS CLOUDED
100/3
TVSS
CURRENT TECHNOLOGY
XN100-120/208-3GY
OR EQUIVALENT
400/3
400A FUSES
of
ww
w.aec-vail.com
M
echa
nica
l, E
le
ctrica
l &
L
igh
ting
D
esign
S
ervice
s
Architectural E
ngineering C
onsultants
Tele
pho
ne: 97
0-74
8-8
520
Drawn By: Checked By:
DATE: ISSUE:
07-02-15BID SET
AEC PROJECT #:
EA
GLE
C
OU
NT
Y A
IR
PO
RT
AD
MIN
IS
TR
AT
IO
N
OF
FIC
E R
EM
OD
EL
GY
PS
UM
, C
O
15050
An Office with LEED™ Accredited Professionals
GENERAL NOTES:
1. COORDINATE LOCATION OF ALL MECHANICAL EQUIPMENT WITH
MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. COORDINATE
CONNECTION SIZE WITH MANUFACTURER PRIOR TO ROUGH-IN.
2. ALL DEVICES ARE LOCATED AT +18" AFF UNLESS NOTED OTHERWISE.
3. RE-USE EXISTING JUNCTION BOXES AND CONDUITS IF POSSIBLE.
OUTLETS TO BE REMOVED OR RE-WORKED ARE SHOWN. FOR REMOVED
OUTLETS, CUT AND CAP ALL ABANDONED CONDUCTORS AND CONDUITS
AT PANELS AND PROVIDE BLANK FACEPLATE TO COVER ANY ABANDONED
OUTLETS. RE-WORKED OUTLETS SHALL REMAIN IN EXISTING LOCATIONS,
AND RE-CIRCUIT OR RE-CONNECT AS SHOWN ON PLANS.
SHEET DETAIL NOTES:
PROVIDE CONNECTION FOR PRE-WIRED DESK WORKSTATIONS.
COORDINATE CONNECTION TYPE WITH DESK MANUFACTURER PRIOR
TO ROUGH-IN.
EXISTING OUTLET OR DATA WILL BE UN-USED, NOTED DEVICES AND
WIRING SHALL BE REMOVED AND PATCHED AS NECESSARY.
EXISTING OUTLET SHALL BE RE-WORKED, UPDATE CONNECTION AND
CIRCUITING AS SHOWN ON NEW POWER PLANS.
EXISTING PHONE AND DATA CONNECTION SHOWN IS THROUGH OPEN
WALL WITH BARE WIRE, AND DOES NOT HAVE RJ-45 CONNECTION OR
FACEPLATE. ANY NEW DATA CONNECTIONS SHALL NOT BE THROUGH
THE OPEN WALL, AND WILL INCLUDE FACEPLATES.
EXISTING JUNCTION BOX IS FITTED WITH A BLANK FACEPLATE, UNLESS
OTHERWISE NOTED ALL UN-USED DEVICES SHALL BE REMOVED AND
PATCHED WITH DRYWALL.
LOCATE NEW PANEL R1B IN ELECTRICAL ROOM, ADJACENT TO PANEL
R1A IF THERE IS ADEQUATE SPACE. IF ADEQUATE SPACE IS NOT
AVAILABLE LOCATE IN NEW KITCHEN WALL.
1
AC
MW
AC
GFI
AC
GFI
AC
COFFEE
1
R1B-12
R1B-14
R1B-10
R1B-18,20,22
R1B-24
R1B-26
R1B-28
R1B-30
R1B-32
R1B-16
R1B-2
R1B-4
R1B-6
R1B-8
1
1
1
TV
+60"AFF
AREA WILL
REMAIN AS
EXISTING
R1
R1A
2
(E)
(E)
(E)
3
3
3
3
+5'AFF
+5'AFF
+4'AFF
+4'AFF
+5'AFF
(R)
(R)
+4'AFF
+5'AFF
4
4
5
2
3
3
5
(E)(E)
(E)
(E) (R)
(R)
(R)
(R)
(R)
(R)
3
(E)
(E)
(E)
(E)
AC
GFI
COFEE
UC
FRIDGE
AC
GFI
MW
AC
(E)
(E)
(E)
(E)
3
(E)
(E)
(E)
(E)
(R)
3
3
2
2
2
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
2
2
2
2
3
(R) (E) (R) (R)
2 2
2
(R)(R)
(R)
(R)
2
3
(R) (R)
(E)
52
2
2
2
2
2
2
3
5
2
(R)
5
(R)
5
(R)
2
3
3
2
2
2
AC
3
3
3
3
3
FRIDGE
3
3
3
(E)
(E)
3
(E)
(E)
(E)
(E)
3
(E)
3
F
2
F
1
CU
1
CU
2
R1B-1,3
TO
TO
R1B-7,9
R1B-5
R1B-11
R1B
6
6
of
ww
w.aec-vail.com
M
echa
nica
l, E
le
ctrica
l &
L
igh
ting
D
esign
S
ervice
s
Architectural E
ngineering C
onsultants
Tele
pho
ne: 97
0-74
8-8
520
Drawn By: Checked By:
DATE: ISSUE:
07-02-15BID SET
AEC PROJECT #:
EA
GLE
C
OU
NT
Y A
IR
PO
RT
AD
MIN
IS
TR
AT
IO
N
OF
FIC
E R
EM
OD
EL
GY
PS
UM
, C
O
15050
An Office with LEED™ Accredited Professionals
NORTH
NEW POWER & SYSTEMS PLAN
SCALE: 1/4" = 1'0"
NORTH
DEMOLITION POWER & SYSTEMS PLAN
SCALE: 1/4" = 1'0"
A
A
A A
A
A
A
A
A
AA
AAAA
A A A A
AAA
AA A
PP
P
P
P
P
P
P
M
M
B
BB
B
B
SWITCHING
SHALL
REMAIN AS
EXISTING
AREA WILL
REMAIN AS
EXISTING
REUSE
EXISTING
SWITCHING
B
C
D
AREA WILL
REMAIN AS
EXISTING
E
E
SWITCHING
SHALL
REMAIN AS
EXISTING
P
of
ww
w.aec-vail.com
M
echa
nica
l, E
le
ctrica
l &
L
igh
ting
D
esign
S
ervice
s
Architectural E
ngineering C
onsultants
Tele
pho
ne: 97
0-74
8-8
520
Drawn By: Checked By:
DATE: ISSUE:
07-02-15BID SET
AEC PROJECT #:
EA
GLE
C
OU
NT
Y A
IR
PO
RT
AD
MIN
IS
TR
AT
IO
N
OF
FIC
E R
EM
OD
EL
GY
PS
UM
, C
O
15050
An Office with LEED™ Accredited Professionals
NORTH
LIGHTING & RCP PLAN
SCALE: 1/4" = 1'0"