Existalite ICM intelligent emergency lighting T8...

6
Lamp Compatibility T5 T8 TC-SEL TC-DEL TC-TEL TC-L TC-DD T5-R Existalite ICM : a range of advanced low profile conversion modules combining highly efficient DC-AC inverter circuits with an intelligent testing protocol, to effectively operate and monitor fluorescent lighting in emergency mode. The Existalite ICM intelligent emergency lighting module is capable of driving a wide range of 4-Pin fluorescent lamps from 4 to 80 W, whilst simultaneously fulfilling the test requirement for emergency lighting in line with IEC 62034. Available as either conversion module with battery for integration into existing mains fluorescent lamps, or fully assembled remote conversion kit for installations where space or temperature restrictions make integral conversions impossible. Existalite ICM intelligent emergency lighting conversion module

Transcript of Existalite ICM intelligent emergency lighting T8...

Page 1: Existalite ICM intelligent emergency lighting T8 ...tnblnx3.tnb.com/emAlbum/albums//EU/Existalite/_fullsize/ThomasBet… · Lamp Compatibility T5 T8 TC-SEL TC-DEL TC-TEL TC-L TC-DD

Lamp Compatibility

T5

T8

TC-SEL

TC-DEL

TC-TEL

TC-L

TC-DD

T5-R

Existalite ICM : a range of advanced low profileconversion modules combining highly efficient

DC-AC inverter circuits with an intelligent testingprotocol, to effectively operate and monitor

fluorescent lighting in emergency mode.

The Existalite ICM intelligent emergency lighting module is capable of driving a wide

range of 4-Pin fluorescent lamps from 4 to 80 W, whilst simultaneously fulfilling

the test requirement for emergency lighting in line with IEC 62034.

Available as either conversion module with battery for integration into existing

mains fluorescent lamps, or fully assembled remote conversion kit for installations

where space or temperature restrictions make integral conversions impossible.

Existalite ICM intelligentemergency lightingconversion module

TNB 2610 6ppor4pp ICM (Final Artwork) with amends (Thursday) 12/01/2012 11:31 Page 4

Page 2: Existalite ICM intelligent emergency lighting T8 ...tnblnx3.tnb.com/emAlbum/albums//EU/Existalite/_fullsize/ThomasBet… · Lamp Compatibility T5 T8 TC-SEL TC-DEL TC-TEL TC-L TC-DD

ICM | page 2

Technical specification : ICM

Mains voltage 230-240 Vac

Mains frequency 50 Hz

Mains current 50 mA max. (module only)

Charge current 200 mA/100 mA, dual rate charger

Discharge current 1100 mA nominal

Charge indicator Green LED

Emergency duration 3 hours as standard (1 hour to special order)

Recharge period 24 hours

Changeover voltage In compliance with EN 60598-2-22

Module case temperature range 0-70 °C at 25 °C room ambient temperature

Ingress protection IP20

Safety class I

Weight 0.15 kg

Case material Aluminium

Approvals ENEC approved. Complies with the safety andperformance requirements of EN 55015, EN 61547, EN 61000, EN 61347, EN 60925, EN 60598-2-22. CE marked

Dimensions Fixing Centres 220 mm

Existalite ICMintelligentemergency lightingconversion module

5-pole connection to lamp circuitvia 4-pole changeover device anddelayed energy relay whichdisconnects the ballast live supplyduring testing

Industry leading ballast lumen factor

3 hour emergency duration asstandard (1 hour to specialorder), with 24 hour recharge

Constant current charge circuit with battery deep discharge protection

Supplied with IDC/push-wireterminals suitable for automatedand manual assembly

Fully ENEC and CE marked

Complies with the EMC Directive

Electronic circuitry complies withthe relevant EN standards

In-built Self-Test intelligenttesting functionality, with centraladdressable testing as an option

Remote enclosures

Remote conversion kits are available for use where luminaire internal temperatures are too high,or luminaires have insufficient internal room for the conversion module and battery.

Kits comprise all necessary components: geartray, battery and cable loom. IP20 remoteenclosures are available as standard, with IP54 rated kits to special order (contact Thomas & Bettsto discuss particular requirements).

Technical specification : IP20 enclosure

Wiring 1.2 m colour-coded high temperature single core cable with terminals and 0.5 m protective loom

Cable entry 20 mm cut-out

Mounting Two fixing holes in base

Case material Zinc plated steel

Dimensions

431 mm

112 mm

44 mm

33 mm

230 mm

22 mm

TNB 2610 6ppor4pp ICM (Final Artwork) with amends (Thursday) 12/01/2012 11:31 Page 5

Page 3: Existalite ICM intelligent emergency lighting T8 ...tnblnx3.tnb.com/emAlbum/albums//EU/Existalite/_fullsize/ThomasBet… · Lamp Compatibility T5 T8 TC-SEL TC-DEL TC-TEL TC-L TC-DD

Existalite ICM intelligent emergency lighting conversion module

page 5 | ICM

ICM automated testing

Existalite ICM modules include Self-Testfunctionality as standard, with the optionto upgrade to central addressable testingthrough addition of a 'FittingLink' interfacemodule.

Self-Test continuously monitors theemergency lighting circuit and runsfunctional tests at specific times in line with appropriate standards. Faults areindicated locally at the luminaire.

Central addressable testing offers a more comprehensive solution designed to permit management of tests from aconvenient central location.

For central addressable conversions, theExistalite ICM module is connected to a‘FittingLink’ module which provides thedata link (via an interface) to the centralcontrol unit.

Up to 750 emergency lighting units can be controlled by each interface (depending on cabling limitations).

Ground Floor

First Floor

Ground Floor

First Floor

ISOLATOR

ISOLATOR

Emergency exit sign

Emergency lighting conversion

Emergency lighting fault

Key

Mains luminaire

Interface

Central control PC

Mains supply

Twisted pair data cable

RS232 cable

a Self-Test Central addressable

System structure

ICM module integrated into luminaire or sited in adjacent remote boxprovides local fault monitoring and indication

ICM module and FittingLink addressable module integrated intoluminaire or sited in adjacent remote box. Modules are linked viainterface units to central control unit (PC or panel) where systemtesting is initiated/managed

Test performance

System start Commissioning test once mains supply has been steady for 24 hours

Monthly Function test

Annually Full duration test, which can be offset for 24 hours to allow testing during periods of least risk

Manual Push button test

System start Commissioning test once mains supply has been steady for 24 hours

Monthly Function test

Annually Full duration test, fully programmable to allow testing at periods of least risk

Manual Push button test at luminaire, with manual test schedules programmable from central control unit

Test monitoring

Mains supply healthy/battery voltage, capacity and duration/chargecurrent/module function/lamp operation/circuit integrity

Mains supply healthy/battery voltage, capacity and duration/chargecurrent/module function/lamp operation/circuit integrity

Fault indication

Luminaire status indicated locally by green and amber LEDs. Fault indication automatically cancelled when the fault is rectifiedand the luminaire retested

Luminaire status indicated locally by green and amber LEDs andlogged centrally at the control unit. Fault indication automaticallycancelled when the fault is rectified and the luminaire retested

Test results Manually logged by user Test results downloaded to a report file which includes the type, location and details of any failed luminaires

Self-Test automated testing

Technical specification

Central addressable testing

Note: the Existalite ICM module is fully compatible with existing Existalite SureTEST and ExiTEST installations.

TNB 2610 6ppor4pp ICM (Final Artwork) with amends (Thursday) 12/01/2012 11:31 Page 2

Page 4: Existalite ICM intelligent emergency lighting T8 ...tnblnx3.tnb.com/emAlbum/albums//EU/Existalite/_fullsize/ThomasBet… · Lamp Compatibility T5 T8 TC-SEL TC-DEL TC-TEL TC-L TC-DD

page 3 | ICM

Product selection

Existalite ICM conversion equipmentcan be offered as separate individualcomponents or complete kitsdependent on your specific projectrequirements.

Select the appropriate module forthe lamp type (using the ballastlumen factor chart on page 4) anddetermine your full requirementfrom the table shown right. Allmodels shown are 3 hour duration.1 Hour modules to special order.

If you require further assistanceregarding installation and wiring ofconversion modules to specific lamptypes, please contact Thomas &Betts on +44 (0)113 281 0600.

Batteries

Existalite ICM intelligent modules can besupplied with advanced hightemperature Nickel Cadmium (NiCad)batteries which, when properly installedin compliance with the EN 60598-2-22product standard, are designed to give aminimum of 4 years service life.

Batteries are available in a range ofconfigurations for best fit to availablespace within the luminaire.

Side by side battery sticks of the samesize (e.g. 2 x 2 cell) can be slottedtogether by the end caps, permittingbatteries to be fixed using only 2 screws.

Technical specification : Batteries

Battery High temperature Nickel Cadmium

Battery temperature (continuous) 0-55 ºC

Service life Minimum 4 years (when installed in compliance with EN 60598-2-22)

Battery voltage per cell 1.2 V

Capacity 4 Ah

Connectors Non-reversible, with 200 mm leads as standard (other lengths supplied to special order)

Configurations Stick : 1 x 3 cell, 1 x 4 cell, 1 x 5 cell, 1 x 6 cellSide by side : 2 x 2 cell, (1 x 2) + (1 x 3), 2 x 3 cell

Termination Battery end caps fitted as standard on stick and side by side battery configurations

Weight 3 cell : 0.4 kg. 4 cell : 0.5 kg. 5 cell : 0.8 kg. 6 cell : 1.0 kg

Dimensions2 cell 3 cell 4 cell 5 cell 6 cell

Length (mm) 157 216 275 333 392Fixing centres (mm) 146 205 264 322 381

Ordering as separates Ordering as kits

ModulePrefix

No. ofbatteries

Base module

Battery codes Integral module + battery

IP20 Remote kit

Stick Side by side

ICM343 3 ICM343 BTF078 - ICK3 ICK3S

ICM343 4 ICM343 BTF030 BTF079 ICK4 ICK4S

ICM563 5 ICM563 BTF040 BTF080 ICK5 ICK5S

ICM563 6 ICM563 BTF005 BTF002 ICK6 ICK6S

Modules are supplied with green LED including 1 m connecting lead as standard.IP54 rated remote kits to special order. Contact Thomas & Betts for further information.

length

35 mm

39.5 mm77.5 mm

length

35 mm

Important note

To maintain compliance with ENEC Certification and warranty ofconversion equipment, ICM modules must be connected to Existaliteapproved batteries as specified in the product selection chart.

TNB 2610 6ppor4pp ICM (Final Artwork) with amends (Thursday) 12/01/2012 11:32 Page 6

Page 5: Existalite ICM intelligent emergency lighting T8 ...tnblnx3.tnb.com/emAlbum/albums//EU/Existalite/_fullsize/ThomasBet… · Lamp Compatibility T5 T8 TC-SEL TC-DEL TC-TEL TC-L TC-DD

Existalite ICM intelligent emergency lighting conversion module

page 4 | ICM

Module ballast lumenfactor (% of normal lamp output lumens)

The chart shown right establishesthe ballast lumen factor (BLF) ofExistalite ICM intelligent modulesand remote conversion kits.

To select the correct module, crossreference the lamp type to beconverted with the relevant modulereference, to achieve the stated BLF(e.g. ICM343 module converts an 8 W T5 lamp to emergency use,with 3 hour duration and providinga BLF of 24%).

The required number of battery cellsfor each lamp is also shown.

Conversion notes

1. All emergency lighting conversions should be undertaken in accordance with relevantnational requirements and codes of practice,including ICEL 1004.

2. Converted luminaires should comply with EMC and Low Voltage Directives in order to carry the CE mark.

3. When remote mounting, the connecting cable between the lamp and the module/battery should not exceed 1 m.

Module type 3 Hr duration ICM343 ICM343 ICM563 ICM563

Battery cells 3 4 5 6

Lamp type aT5 4 W 26

T5 6 W 28

T5 8 W 24

T5 13 W 23

T5 14 W 19

T5 21 W 9

T5 24 W 14

T5 28 W 10

T5 35 W 11

T5 39 W 10

T5 49 W 7

T5 54 W 6

T5 80 W 6

T5-R 22 W 11

T5-R 40 W 9

T5-R 55 W 9

T5-R 60 W 7

T8 16 W 18

T8 18 W 14

T8 30 W 9

T8 32 W 8

T8 36 W 8

T8 38 W 8

T8 51 W 5

T8 58 W 5

T8 70 W 6

TC-DEL 10 W 21

TC-DEL 13 W 22

TC-DEL 18 W 14

TC-DEL 26 W 10

TC-TEL 13 W 21

TC-TEL 18 W 13

TC-TEL 26 W 9

TC-TEL 32 W 10

TC-TEL 42 W 11

TC-SEL 9 W 34

TC-SEL 11 W 22

TC-L 18 W 17

TC-L 24 W 14

TC-L 34 W 9

TC-L 36 W 11

TC-L 40 W 8

TC-L 55 W 8

TC-L 80 W 5

TC-DD 10 W 20

TC-DD 10 W 10

TC-DD 28 W 10

TC-DD 38 W 9

TC-DD 55 W 11

For alternative lamp types not shown above (T5 ECO lamp etc), please contact Thomas & Betts.

TNB 2610 6ppor4pp ICM (Final Artwork) with amends (Thursday) 12/01/2012 11:32 Page 7

Page 6: Existalite ICM intelligent emergency lighting T8 ...tnblnx3.tnb.com/emAlbum/albums//EU/Existalite/_fullsize/ThomasBet… · Lamp Compatibility T5 T8 TC-SEL TC-DEL TC-TEL TC-L TC-DD

UK OFFICE

Thomas & Betts Limited

Existalite

Bruntcliffe Lane

Leeds

West Yorkshire

LS27 9LL

Tel +44 (0)113 281 0600

Fax +44 (0)113 281 0601

[email protected]

www.existalite.co.uk

EUROPEAN HEADQUARTERS

Thomas & Betts

European Centre SA

200 Chaussée de Waterloo

B-1640 Rhode-St-Genèse

Belgium

Tel +32 (0)2 359 8200

Fax +32 (0)2 359 8201

www.tnb-europe.com

MIDDLE EAST OFFICE

Thomas & Betts Ltd. Br.

Office 724 6WA West Wing

Dubai Airport Free Zone

PO Box 54567

Dubai

United Arab Emirates

Tel +971 (0)4 609 1635

Fax +971 (0)4 609 1636

[email protected]

SOUTH EAST ASIA OFFICE

Thomas & Betts Asia (Singapore) Pte Ltd

10 Ang Mo Kio Street 65

#06-07 Techpoint

Singapore 569059

Tel +65 6720 8828

Fax +65 6720 8780

[email protected]

UKASQUALITY

MANAGEMENT

BSI

003

FM09470

A member of theLIGHTING INDUSTRY FEDERATION

The content of this Thomas & Betts publication has been carefully checked for accuracy at the time of print. However, Thomas & Bettsdoesn’t give any warranty of any kind, express or implied, in this respect and shall not be liable for any loss or damage that may resultfrom any use or as a consequence of any inaccuracies in or any omissions from the information which it may contain. E&OE.

Copyright Thomas & Betts Corp. 2011. Copyright in these pages is owned by Thomas & Betts except where otherwise indicated. No partof this publication may be reproduced, copied or transmitted in any form or by any means, without our prior written permission.Existalite is a brand owned by Thomas & Betts. Images, trade marks, brands, designs and technology are also protected by otherintellectual property rights and may not be reproduced or appropriated in any manner without written permission of their respectiveowners. Thomas & Betts reserves the right to change and improve any product specifications or other mentions in the publication at itsown discretion and at any time. These conditions of use are governed by the laws of the Netherlands and the courts of Amsterdam shallhave exclusive jurisdiction in any dispute.

TBEX-ICM-1011

TNB 2610 6ppor4pp ICM (Final Artwork) with amends (Thursday) 12/01/2012 11:31 Page 3