Ex isolating spark gaps Examples of use

24
© 2007 DEHN + SÖHNE / protected by ISO 16016 Ex isolating spark gaps Examples of use

description

Ex isolating spark gaps Examples of use. Ex isolating spark gap EXFS 100; Part No. 923 100 Application environment. Isolating spark gaps or protective spark gaps are supposed to establish a galvanic isolation of electric parts of the installation, which are not connected with - PowerPoint PPT Presentation

Transcript of Ex isolating spark gaps Examples of use

Page 1: Ex isolating spark gaps  Examples of use

© 2007 DEHN + SÖHNE / protected by ISO 16016

Ex isolating spark gaps

Examples of use

Page 2: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016

Ex isolating spark gap EXFS 100; Part No. 923 100Application environment

14.01.08 / 5242e

Isolating spark gaps or protective spark gaps are supposed to establish a galvanic isolation of electric parts of the installation, which are not connected with each other under normal operating conditions.

- Specific applications:• for establishing a galvanic isolation of insulating

flanges and insulated couplings (e.g. fuel pipes) • Cathodic corrosion protection of tanks• Cathodic corrosion protection of pipelines• Lightning equipotential bonding of gas pressure regulation stations

Assembly:Isolating spark gaps can be mounted between the parts of the installation to be bridged by means of brackets or connectors. When mounting isolating sparks, the shortest possible cable length should be used as long cables increase the danger of inductive voltages putting unnecessary stress on the isolation.

Page 3: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016

Ex isolating spark gap EXFS 100; Part No. 923 100Application

14.01.08 / 5238e

Page 4: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016

EXFS 100

Cathodic corrosion protection of tank installatins

building earth

+

~

14.01.08 / 5300e

Page 5: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016

Insulating flange of fuel or product pipelines

insulating flange

building earth

14.01.08 / 5301e

EXFS 100

Page 6: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016

Insulating flange of fuel or product pipelines

insulating flange

insulatingflange

+

~

14.01.08 / 5302e

EXFS 100

EXFS 100

Page 7: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016

Insulating flange of fuel or product pipelines

insulating flange

insulating flange

gas pressure regulator

14.01.08 / 5303e

EXFS 100

EXFS 100

Page 8: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016

Installation of EXFS 100

pipeline pipeline

minimumdistance2 cm

EXFS 100

14.01.08 / 5304e

EXFS 100

Page 9: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016

Insulating flange16 mm² Cu

earth-termination system

14.01.08 / 5305e_a

ground

cathodiccorrosion protection

electric actuator, e.g. MOV (motor operated valve)

Installation of EXFS 100

Page 10: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016

ground

16 mm² Cu

earth-termination system

14.01.08 / 5305e_b

detail

EXFS 100

Insulating flange

cathodiccorrosion protection

electric actuator, e.g. MOV (motor operated valve)

Installation of EXFS 100

Page 11: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016

ground

16 mm² Cu

earth-termination system

14.01.08 / 5305e_c

detail

EXFS 100cathodiccorrosion protection

Installation of EXFS 100

electric actuator, e.g. MOV (motor operated valve)

Insulating flange

Page 12: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016

arrangement as required CCP - side

14.01.08 / 5306e

Reference: Eon Ruhrgas

loop

Installation of EXFS 100

loop < 30

0 m

m<

300

mm

Page 13: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016

Installation of EXFS 100 if several pipelines are run closely in parallel and insulating units installed directly side by side.

Type A Type B

14.01.08 / 5307e

If possible the isolating spark gaps shall be installed symmetrically between the pipelines.

Reference: Eon Ruhrgas

loop

Installation of EXFS 100

Page 14: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016

Type C

14.01.08 / 5308e

Installation of EXFS 100

Page 15: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016 14.01.08 / 5317e_a

Ex isolating spark gaps EXFS 100 (KU)Application

Reference: Schwelm Anlagentechnik GmbH, Austria

Page 16: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016

Ex isolating spark gaps EXFS 100 (KU)Application

Reference: Schwelm Anlagentechnik GmbH, Austria

14.01.08 / 5317e_b

Page 17: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016

Ex isolating spark gaps EXFS 100 (KU)Application

Reference: Schwelm Anlagentechnik GmbH, Austria

14.01.08 / 5317e_c

Page 18: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016

Ex isolating spark gaps EXFS 100 (KU)Application

Reference: Schwelm Anlagentechnik GmbH, Austria

14.01.08 / 5317e_d

Page 19: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016

Ex isolating spark gaps EXFS 100 (KU)Application

Reference: Schwelm Anlagentechnik GmbH, Austria

14.01.08 / 5317e_e

Page 20: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016

Ex isolating spark gaps EXFS 100 (KU)Application

Reference: Schwelm Anlagentechnik GmbH, Austria

14.01.08 / 5317e_f

Page 21: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016

Ex isolating spark gaps EXFS 100 (KU)Application

Reference: Schwelm Anlagentechnik GmbH, Austria

14.01.08 / 5317e_g

Page 22: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016

Ex isolating spark gaps EXFS 100 (KU)Application

Reference: Schwelm Anlagentechnik GmbH, Austria

14.01.08 / 5317e_h

Page 23: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016

Ex isolating spark gaps EXFS 100 (KU)Application

Reference: Schwelm Anlagentechnik GmbH, Austria

14.01.08 / 5317e_i

Page 24: Ex isolating spark gaps  Examples of use

EXFS 100© 2007 DEHN + SÖHNE / protected by ISO 16016

Ex isolating spark gaps EXFS 100 (KU)Application

Reference: Schwelm Anlagentechnik GmbH, Austria

14.01.08 / 5317e_j