Everywhere - Alpine Air
Transcript of Everywhere - Alpine Air
![Page 1: Everywhere - Alpine Air](https://reader031.fdocuments.us/reader031/viewer/2022012223/61e07123efb44600a025f797/html5/thumbnails/1.jpg)
MINI SPLIT2018
ENERGY EFFICIENT RANGE
WALL MOUNTED CEILING / FLOOR CASSETTE DUCTED
Cooling output kW ***Energy efficiency ratio ***
Noise (optional)(dB(A) re 1 pW)Further information is contained in the product brochure.
Norm SANS 54511-3
ENERGYREPU
BLIC OF SOUTH AFRI
CA
• E
NERGY EFFICIENCY •
Manufacturer
Outside unitInside unit
********
Annual energry consumption,kWh, in cooling mode
Type: Cooling only Cooling + heating Air cooled Water cooled Heat output kW *** Heating performance A++A+ABCDE
Actual consumption will depend on how the appliance is used and the climate.
B
***
***
More e�cient
Less e�cient
A++A+
A
B
CD
E
Full load (the higher the better)
* Wall Mount 0-24 000 BTU
![Page 2: Everywhere - Alpine Air](https://reader031.fdocuments.us/reader031/viewer/2022012223/61e07123efb44600a025f797/html5/thumbnails/2.jpg)
1 MINISPLIT RANGE 2018
WHAT WE OFFER UNITARY SPLIT SYSTEMS (in both on/off and DC Inverter)• Midwall• 4-way Cassette• Floor/Ceiling
CHILLED WATER
WHAT YOU NEEDEco Aire designs and manufactures residential, commercial and industrial Air Conditioning Units. We give comprehensive input into the manufacturing process, ensuring the product is of superb quality and suited to South Africa conditions. Eco Aire provides full technical support and spare parts to its clients.
WHERE YOU NEED ITOur head office is in Jet Park, Johannesburg and we have sales offices in the Western Cape, Eastern Cape, the Garden Route, KwaZulu Natal, Free State, North West and Mpumalanga. We have a national distribution network throughout South Africa as well as in Namibia, Botswana, Zimbabwe, Mozambique, Zambia. We have a fully fledged Engineering office in Ningbo.
WHERE WE ARE GOINGThe HVAC market worldwide is moving towards an emphasis on Eco-friendly units. It is vital that we stay abreast of developments which limit the release of harmful gases into the atmosphere and encourage the responsible use and re-use of energy. As such Eco Aire is in a leading position as we offer a range of systems which will achieve that for various applications: R410 Inverter Systems, Heat Pipe Energy Recovery Systems, 3-stage Evaporative Cooling Systems and 4-stage Hybrid Systems with a COP of >8.
FANCOIL (both AC and EC type)• Midwall• Console• Under ceiling
PACKAGED(in both on/off and DC Inverter)• Ducted Split• Rooftop (Water/ Air cooled)• Vertical and Horizontal Water Cooled Package Units• Hospital Theatre Package Units• Units custom made for Industrial application
FRESH AIR UNITS• Fresh Air Heat Pipe with Single Stage Dry Cooler• Fresh Air Dual Stage Dry Cooler
AIR HANDLING UNITS• Horizontal
CHILLERS• Air cooled
EVAPORATIVE COOLING• Two & Three Stage Evaporative Coolers
VRFEco Aire is the agent for Hitachi’s VRF systems in South Africa. We offer both Heat Pump and Heat Recovery. With the unique CS-Networking system we are able to successfully communicate to building management systems. The flexibility of the system allows the internal data to be easily accessed and controlled by the user, with features including temperature, mode and fan speed setting and groupings.
ACCESSORIESPipe kits, Brackets, Condensate Pumps, Inverters (VSD), Valves & Actuators, Controls
SERVICEEco Aire offers a conditional one year warrantee on all products and has a full range of spares available nationwide to minimize down time. Extensive technical back-up is provided. Commissioning of units and training are integral parts of our service.
• Ducted (hideaway)• Evaporative Coolers• Air Curtains
• 4-way Cassette• Ducted (low & high static)
Eco Aire Pty Ltd was founded in 1997 and has grown into a market leader in the Air Conditioning Industry to such an extent that Eco Aire is literally EVERYWHERE in South Africa (Reference list at the back). We have also expanded internationally and have sold our product in Australia, Albania, China as well as several African countries. Eco Aire offers a wide range of product, extra-ordinary service, value for money and excellent quality. Regardless of the Engineering challenge, Eco Aire is there – able and willing to assist! Eco Aire has an “offer what is required” rather than a “buy what we have” approach. Technically speaking, there is only one choice!
…for you!
WHAT YOU NEED WHERE YOU NEED IT TECHNICAL SUPPORT EXCELLENT VALUE
Everywhere
• Hybrid units
• Vertical
• Water cooled
![Page 3: Everywhere - Alpine Air](https://reader031.fdocuments.us/reader031/viewer/2022012223/61e07123efb44600a025f797/html5/thumbnails/3.jpg)
2
MINI SPLITRANGE
Our mini split units are energy efficient and elegant, adding comfort and style to every room in your house. Keeping you warm in winter and cool in summer while operating quietly, these units will enhance your home or office and keep you comfortable year round.
Eco Aire units use inverter technology which means that the unit continuously adjusts its cooling and heating outputs according to the room temperature. This saves a great deal of energy making it 30% cheaper for you to run compared to a traditional on/off system. The inverter keeps the unit running in a very narrow band of temperature which means you stay comfortable the whole day. Start-up time is reduced by the inverter and once the desired temperature is reached the inverter monitors and maintains that temperature at a constant level.
ECO INVERTER TECHNOLOGY- increasing energy efficiency
INTERESTING FACT:Eco Aire units in heat pump phase obtain 75% of their output energy from the ambient air. This means that you only pay for 25% of the electricity it needs.
QUIET COMFORTABLE ECONOMICAL
![Page 4: Everywhere - Alpine Air](https://reader031.fdocuments.us/reader031/viewer/2022012223/61e07123efb44600a025f797/html5/thumbnails/4.jpg)
3 MINISPLIT RANGE 2018
WALL MOUNTEDON - OFF PRODUCT FEATURES
> Quiet operation > Vertical auto swing > Dehumidification > Fan only> 24 hour timer > Infra red remote > Auto Restart
Model No. Outdoor / Indoor C09C/C09E C12C/C12E C18C/C18E C24C/C24E C32C/C32E
Power supply 220-240V/1PH/50Hz
PERFORMANCE
CapacityCooling
BTU/h 9000 12000 18000 24000 32000W 2600 3200 5100 6100 8800
HeatingBTU/h 9000 12000 18000 24000 32000
W 2700 3400 5300 6100 9200
Noise LevelIndoor dB(A) 29-40 29-42 36-46 36-48 48-53
Outdoor dB(A) 52 54 54 56 59
Air Flow Volume m3/h 600 600 1000 1200 1400
Suitable Area m2 15 20 30 35 55
E.E.R. / C.O.P. w/w 3.06 / 3.42 3.06 / 3.11 3.06 / 3.15 3.18 / 3.22 2.93 / 3.12
POWER
Input powerCooling W 850 1045 1670 1900 3000
Heating W 790 1060 1650 1800 2950
Running CurrentCooling A 3.8 4.5 7.4 8.2 13
Heating A 3.5 4.6 7.3 7.8 12.8
Max Input powerCooling W 1150 1360 2500 2600 3950
Heating W 1100 1260 2400 2500 3800
Max Running Current A 6.4 7.3 14.0 14.5 17.2
Power supply Wire Size - Indoor 3 x 1.5mm2 3 x 1.5mm2 3 x 2.5mm2 3 x 2.5mm2 -
Power supply Wire Size - Outdoor - - - - 3 x 2.5mm²
Communication Wire 5 x 1.5mm2 5 x 1.5mm2 5 x 1.5mm2 3 x 2.5mm² + 2 x 1.5mm² 4 x 1.5mm2
Circuit Breaker Size 10A 10A 20A 20A 25A
OTHER
Tubing SizeGas mm/inch 9.52 / 3/8” 9.52 / 3/8” 12.7 / 1/2” 12.7 / 1/2” 15.88 / 5/8”
Liquid mm/inch 6.35 / 1/4” 6.35 / 1/4” 6.35 / 1/4” 6.35 / 1/4” 9.52 / 3/8”
Maximum Tubing Distance Length m 10 10 15 15 15
Maximum Height Difference Height m 5 5 5 5 5
WEIGHT
Indoor unit Nett kg 10 10 14 16 22
Outdoor unit Nett kg 25 28 42 42 73
SPECIFICATIONS (E&OE)
A B C
C09E 789 294 234
C12E 789 294 234
C18E 956 328 259
C24E 1060 322 258
C32E 1300 354 288
Cooling output kW 2.60Energy efficiency ratio 3.06
Noise (optional)(dB(A) re 1 pW)Further information is contained in the product brochure.
Norm SANS 54511-3
ENERGYREPUBL IC OF SO UTH A
FRIC
A
• E
NERGY EFFICIENCY •
Manufacturer
Outside unitInside unit
C09CC09E
Annual energry consumption,kWh, in cooling mode
Type: Cooling only Cooling + heating Air cooled Water cooled Heat output kW 2.70 Heating performance A++A+ABCDE
Actual consumption will depend on how the appliance is used and the climate.
B
425
40
More e�cient
Less e�cient
A++A+
A
B
CD
E
Full load (the higher the better)
3.20 3.06
C12CC12E
3.40 A++A+ABCDE
B
523
42
5.10 3.06
C18CC18E
5.30 A++A+ABCDE
B
833
46
6.10 3.18
C24CC24E
6.10 A++A+ABCDE
B
959
48
Cooling & Heating
A B C D
C09C 700 225 500 510
C12C 715 235 540 420
C18C 850 295 606 505
C24C 850 295 606 505
C32C 970 370 790 590
![Page 5: Everywhere - Alpine Air](https://reader031.fdocuments.us/reader031/viewer/2022012223/61e07123efb44600a025f797/html5/thumbnails/5.jpg)
WALL MOUNTED 4
INVERTER
Model No. Outdoor / Indoor C09CI/C09EI C12CI/C12EI C18CI/C18EI C24CI/C24EI
Power supply 220-240V/1PH/50Hz
PERFORMANCE
CapacityCooling
BTU/h 9000 12000 18000 24000W 2500 3200 5100 6000
HeatingBTU/h 9000 12000 18000 24000
W 2800 3500 5200 5700
Noise LevelIndoor dB(A) 28-40 30-42 42-46 42-48
Outdoor dB(A) 50 53 55 55
Air Flow Volume m3/h 600 600 850 1050
Suitable Area m2 15 20 30 35
E.E.R. / C.O.P. w/w 3.21 / 3.41 3.08 / 3.43 3.22 / 3.41 3.01 / 3.41
POWER
Input powerCooling W 780 1040 1585 1995
Heating W 820 1020 1525 1670
Running CurrentCooling A 3.4 4.7 6.9 8.7
Heating A 3.6 4.5 6.7 7.3
Max Running Current A 7 8 13.5 15
Power supply Wire Size - Indoor 3 x 1.5mm2 3 x 1.5mm2 3 x 2.5mm2 3 x 2.5mm2
Power supply Wire Size - Outdoor - - - -
Communication Wire 4 x 1.5mm2 4 x 1.5mm2 4 x 1.5mm2 4 x 2.5mm2
Circuit Breaker Size 10A 10A 20A 20A
OTHER
Tubing SizeGas mm/inch 9.52 / 3/8” 9.52 / 3/8” 12.7 / 1/2” 12.7 / 1/2”
Liquid mm/inch 6.35 / 1/4” 6.35 / 1/4” 6.35 / 1/4” 6.35 / 1/4”
Maximum Tubing Distance Length m 10 10 15 15
Maximum Height Difference Height m 5 5 5 5
WEIGHT
Indoor unit Nett kg 10 10 14 16
Outdoor unit Nett kg 27 27 40 45
A B C D
C09CI 715 235 538 420
C12CI 715 235 538 420
C18CI 850 295 606 505
C24CI 850 295 606 505
PRODUCT FEATURES> Quiet operation > Vertical auto swing > Dehumidification > Fan only> 24 hour timer > Infra red remote > Auto Restart
SPECIFICATIONS (E&OE)
Cooling output kW 2.50Energy efficiency ratio 3.21
Noise (optional)(dB(A) re 1 pW)Further information is contained in the product brochure.
Norm SANS 54511-3
ENERGYREPUBL IC OF SO UTH A
FRIC
A
• E
NERGY EFFICIENCY •
Manufacturer
Outside unitInside unit
C09CIC09EI
Annual energry consumption,kWh, in cooling mode
Type: Cooling only Cooling + heating Air cooled Water cooled Heat output kW 2.80 Heating performance A++A+ABCDE
Actual consumption will depend on how the appliance is used and the climate.
A
389
40
More e�cient
Less e�cient
A++A+
A
B
CD
E
Full load (the higher the better)
3.20 3.08
C12CIC12EI
3.50 A++A+ABCDE
B
519
40
5.10 3.22
C18CIC18EI
5.20 A++A+ABCDE
A
792
46
6.00 3.01
C24CIC24EI
5.70 A++A+ABCDE
B
997
48
Cooling & Heating
A B C
C09EI 789 294 234
C12EI 789 294 234
C18EI 917 318 246
C24EI 1100 319 258
![Page 6: Everywhere - Alpine Air](https://reader031.fdocuments.us/reader031/viewer/2022012223/61e07123efb44600a025f797/html5/thumbnails/6.jpg)
5 MINISPLIT RANGE 2018
Model No. Outdoor / Indoor CCA18/CEA18 CCA24/CEA24 CCA36/CEA36 CCA48/CEA48 CCA60/CEA60
Power supply 220-240V/1PH/50Hz 380V-415V/3PH/50Hz
PERFORMANCE
CapacityCooling
BTU/h 18000 24000 36000 48000 60000W 5300 7200 10600 14000 17600
HeatingBTU/h 19790 27569 40000 53000 63500
W 5800 8080 11700 15500 18500
Noise Level (H/M/L)Indoor dB(A) 41 / 38 / 32 45 / 42 / 36 48 / 45 / 39 50 / 47 / 41 50 / 47 / 41
Outdoor dB(A) 55 60 60 62 62
Air Flow Volume (H/M/L) m3/h 900 / 720 / 630 1300 / 1040 / 910 1500 / 1200 / 1050 1800 / 1440 / 1260 1800 / 1440 / 1260
Suitable Area m2 21 - 35 28 - 47 42 - 70 64 - 107 64 - 107
E.E.R. / C.O.P. w/w 3.01 - 3.22 3.01 / 3.23 2.81 - 3.34 2.87 / 3.02 3.08 / 3.08
POWER
Input powerCooling W 1760 2390 3770 4870 5710
Heating W 1800 2500 3500 5130 6000
Running CurrentCooling A 8.08 11.06 17.3 8.88 10.42
Heating A 8.27 11.59 16.6 9.33 10.88
Power supply Wire Size - Indoor 3 x 1.5mm2 - 3 x 2.5mm² 3 x 1.5mm² 3 x 1.5mm²
Power supply Wire Size - Outdoor - 3 x 2.5mm² 5 x 2.5mm² 5 x 2.5mm² 5 x 2.5mm²
Communication Wire 3 x 1.5mm² + 2 x 1mm² 3 x 2.5mm² + 3 x 1.5mm² 2 x 1.5mm² 2 x 1.5mm² 2 x 1.5mm²
Circuit Breaker Size 15A 20A 25A 15A 20A
OTHER
Tubing SizeGas mm/inch 12.7 / 1/2” 15.88 / 5/8” 15.88 / 5/8” 19.05 / 3/4” 19.05 / 3/4”
Liquid mm/inch 6.35 / 1/4” 9.25 / 3/8” 9.52 / 3/8” 9.52 / 3/8” 9.52 / 3/8”
Maximum Tubing Distance Length m 20 30 50 50 50
Maximum Height Difference Height m 15 15 30 30 30
WEIGHT
Indoor unit Nett kg 18 24 24 26.5 26.5
Outdoor unit Nett kg 38 50 72 100 101
CEA60CEA48CEA36CEA24CEA18 615 615 263 633
835 835 250 676835 835 250 676835
835835 290 676
290 676835
A B C D E425
778778778
778
CCA60CCA48CCA36CCA24CCA18 800 286 530 546
822 302 655 540903 354 857 606945
945340 1255 610
1255 610340
A B C DA B C D
CCA18 800 286 530 546
CCA24 822 302 655 540
CCA36 903 354 857 606
CCA48 945 340 1255 585
CCA60 945 340 1255 585
A B C D E
CEA18 615 615 263 633 425
CEA24 835 835 250 676 778
CEA36 835 835 250 676 778
CEA48 835 835 290 676 778
CEA60 835 835 290 676 778
CEA60CEA48CEA36CEA24CEA18 615 615 263 633
835 835 250 676835 835 250 676835
835835 290 676
290 676835
A B C D E425
778778778
778
CCA60CCA48CCA36CCA24CCA18 800 286 530 546
822 302 655 540903 354 857 606945
945340 1255 610
1255 610340
A B C D
CEA60CEA48CEA36CEA24CEA18 615 615 263 633
835 835 250 676835 835 250 676835
835835 290 676
290 676835
A B C D E425
778778778
778
CCA60CCA48CCA36CCA24CCA18 800 286 530 546
822 302 655 540903 354 857 606945
945340 1255 610
1255 610340
A B C D CEA60CEA48CEA36CEA24CEA18 615 615 263 633
835 835 250 676835 835 250 676835
835835 290 676
290 676835
A B C D E425
778778778
778
CCA60CCA48CCA36CCA24CCA18 800 286 530 546
822 302 655 540903 354 857 606945
945340 1255 610
1255 610340
A B C D
PRODUCT FEATURES> Quiet operation > Vertical auto swing > Dehumidification > 4 way distribution> Fan only > 24 hour timer > Infra red remote > Auto Restart
SPECIFICATIONS (E&OE)
CASSETTEON - OFFCooling & Heating
![Page 7: Everywhere - Alpine Air](https://reader031.fdocuments.us/reader031/viewer/2022012223/61e07123efb44600a025f797/html5/thumbnails/7.jpg)
CASSETTE 6
Model No. Outdoor / Indoor CCA18I/CEA18I CCA24I/CEA24I CCA36I/CEA36I CCA48I/CEA48I CCA60I/CEA60I
Power supply 220-240V/1PH/50Hz 380-415V/3PH/50Hz
PERFORMANCE
CapacityCooling
BTU/h 18000 24000 36000 48000 60000W 5100 7200 10000 14000 16000
HeatingBTU/h 19000 27000 37500 51000 63000
W 5600 7900 11500 15500 18000
Noise Level (H/M/L)Indoor dB(A) 46 / 41 / 39 45 / 42 / 36 48 / 45 / 39 50 / 47 / 41 50 / 47 / 41
Outdoor dB(A) 55 58 60 56 56
Air Flow Volume (H/M/L) m3/h 750 / 650 / 580 1100 / 880 / 770 1500 / 1200 / 1050 1800 / 1440 / 1260 1800 / 1440 / 1260
Suitable Area m2 21 - 35 28 - 47 42 - 70 56 - 93 64 - 107
E.E.R. / C.O.P. w/w 3.23 / 3.62 3.25 / 3.65 3.24 / 3.63 3.26 / 3.69 3.21 / 3.64
POWER
Input powerCooling W 1579 2220 3086 4294 4984
Heating W 1547 2164 3168 4201 4945
Running CurrentCooling A 7.55 10.6 14.77 7.57 8.6
Heating A 7.4 10.36 15.16 7.45 8.42
Power supply Wire Size - Indoor 3 x 1.5mm2 3 x 1.5mm2 3 x 1.5mm2 3 x 1.5mm2 3 x 1.5mm2
Power supply Wire Size - Outdoor 3 x 1.5mm2 3 x 2.5mm2 3 x 2.5mm2 5 x 2.5mm2 5 x 2.5mm2
Communication Wire 2 x 1mm2 2 x 1mm2 2 x 1mm2 2 x 1mm2 2 x 1mm2
Circuit Breaker Size 15A 20A 25A 15A 15A
OTHER
Tubing SizeGas mm/inch 12.7 / 1/2” 15.88 / 5/8” 15.88 / 5/8” 19.05 / 3/4” 19.05 / 3/4”
Liquid mm/inch 6.35 / 1/4” 9.52 / 3/8” 9.52 / 3/8” 9.52 / 3/8” 9.52 / 3/8”
Maximum Tubing Distance Length m 20 30 30 50 50
Maximum Height Difference Height m 15 15 20 30 30
WEIGHT
Indoor unit Nett kg 17 24 24 26.5 26.5
Outdoor unit Nett kg 37.5 51 62 110 110
SPECIFICATIONS (E&OE)
PRODUCT FEATURES> Quiet operation > Vertical auto swing > Dehumidification > 4 way distribution> Fan only > 24 hour timer > Infra red remote > Auto Restart
INVERTERCooling & Heating
CEA60CEA48CEA36CEA24CEA18 615 615 263 633
835 835 250 676835 835 250 676835
835835 290 676
290 676835
A B C D E425
778778778
778
CCA60CCA48CCA36CCA24CCA18 800 286 530 546
822 302 655 540903 354 857 606945
945340 1255 610
1255 610340
A B C D
CEA60CEA48CEA36CEA24CEA18 615 615 263 633
835 835 250 676835 835 250 676835
835835 290 676
290 676835
A B C D E425
778778778
778
CCA60CCA48CCA36CCA24CCA18 800 286 530 546
822 302 655 540903 354 857 606945
945340 1255 610
1255 610340
A B C D
CEA60CEA48CEA36CEA24CEA18 615 615 263 633
835 835 250 676835 835 250 676835
835835 290 676
290 676835
A B C D E425
778778778
778
CCA60CCA48CCA36CCA24CCA18 800 286 530 546
822 302 655 540903 354 857 606945
945340 1255 610
1255 610340
A B C D CEA60CEA48CEA36CEA24CEA18 615 615 263 633
835 835 250 676835 835 250 676835
835835 290 676
290 676835
A B C D E425
778778778
778
CCA60CCA48CCA36CCA24CCA18 800 286 530 546
822 302 655 540903 354 857 606945
945340 1255 610
1255 610340
A B C D
A B C D
CCA18I 800 286 530 546
CCA24I 890 320 670 632
CCA36I 900 320 790 600
CCA48I 940 368 1366 610
CCA60I 940 368 1366 610
A B C D E
CEA18I 570 570 260 633 425
CEA24I 835 835 250 676 778
CEA36I 835 835 250 676 778
CEA48I 835 835 290 676 778
CEA60I 835 835 290 676 778
![Page 8: Everywhere - Alpine Air](https://reader031.fdocuments.us/reader031/viewer/2022012223/61e07123efb44600a025f797/html5/thumbnails/8.jpg)
7 MINISPLIT RANGE 2018
PRODUCT FEATURES> Quiet operation > Dehumidification > Fan only > 24 hour timer> Wired Remote > Auto Restart
DUCTED - HIDEAWAY
Model No. Outdoor / Indoor CDA24/EDA24 CDA36/EDA36 CDA48/EDA48 CDA60/EDA60
Power supply 220-240V/1PH/50Hz 380-415V/3PH/50Hz
PERFORMANCE
CapacityCooling
BTU/h 24000 36000 48000 60000W 7200 10600 14000 17600
HeatingBTU/h 27500 37500 53000 63500
W 8100 10900 15500 18500
Noise Level (H/M/L)Indoor dB(A) 47 / 44 / 38 50 / 47 / 41 60 / 57 / 51 60 / 57 / 51
Outdoor dB(A) 60 60 62 62
External Static Pressure Pa 80 80 120 120
Air Flow Volume m3/h 1200 1700 2400 2400
E.E.R. / C.O.P. w/w 3.21 / 3.45 2.81 / 3.34 2.87 / 3.02 3.08 / 3.08
POWER
Input powerCooling W 2240 3620 4870 5710
Heating W 2350 3590 5130 6000
Running CurrentCooling A 10,37 17.3 8.88 10.41
Heating A 10,89 16.6 9.33 10.91
Power supply Wire Size - Indoor - - 3 x 1.5mm² 3 x 1.5mm²
Power supply Wire Size - Outdoor 3 x 2.5mm2 3 x 2.5mm2 5 x 2.5mm² 5 x 2.5mm²
Communication Wire 3 x 2.5mm² + 3 x 1mm² 3 x 2.5mm² + 2 x 1mm² 2 x 1mm² 2 x 1mm²
Circuit Breaker Size 20A 25A 15A 15A
OTHER
Tubing SizeGas mm/inch 15.88 / 5/8" 15.88 / 5/8” 19.05 / 3/4” 19.05 / 3/4”
Liquid mm/inch 9.52 / 3/8" 9.52 / 3/8” 9.52 / 3/8” 9.52 / 3/8”
Maximum Tubing Distance Length m 30 50 50 50
Maximum Height Difference Height m 15 30 30 30
WEIGHT
Indoor unit Nett kg 36 36 55 55
Outdoor unit Nett kg 50 72 100 101
SPECIFICATIONS (E&OE)
A B C D
CDA24 822 302 655 540
CDA36 903 354 857 606
CDA48 945 340 1255 585
CDA60 945 340 1255 585
A B C D E F G
EDA24 890 790 295 202 592 290 852
EDA36 890 790 295 202 592 290 852
EDA48 1250 790 295 202 953 290 1212
EDA60 1250 790 295 202 953 290 1212
ON - OFFCooling & Heating
![Page 9: Everywhere - Alpine Air](https://reader031.fdocuments.us/reader031/viewer/2022012223/61e07123efb44600a025f797/html5/thumbnails/9.jpg)
DUCTED 8
DUCTED - HIDEAWAYPRODUCT FEATURES> Quiet operation > Dehumidification > Fan only > 24 hour timer> Wired Remote > Auto Restart
SPECIFICATIONS (E&OE)
Model No. Outdoor / Indoor CDA18I/EDA18I CDA24I/EDA24I CDA36I/EDA36I CDA48I/EDA48I CDA60I/EDA60I
Power supply 220-240V/1PH/50Hz 380-415V/3PH/50Hz
PERFORMANCE
CapacityCooling
BTU/h 18000 24000 36000 48000 60000W 5100 7200 10000 14000 16000
HeatingBTU/h 19000 27000 37500 51000 63000
W 5600 7900 11500 15500 18000
Noise Level (H/M/L)Indoor dB(A) 44 / 41 / 35 47 / 44 / 38 50 / 47 / 41 53 / 50 / 44 53 / 50 / 44
Outdoor dB(A) 55 58 60 56 56
External Static Pressure Pa 60 80 80 120 120
Air Flow Volume m3/h 1125 1200 1700 2400 2400
E.E.R. / C.O.P. w/w 3.23 / 3.62 3.25 / 3.65 3.24 / 3.63 3.26 / 3.69 3.21 / 3.64
POWER
Input powerCooling W 1579 2215 3086 4294 4984
Heating W 1547 2164 3168 4201 4945
Running CurrentCooling A 7.55 10.6 14.77 7.57 8.6
Heating A 7.4 10.36 15.16 7.45 8.42
Power supply Wire Size - Indoor 3 x 1.5mm2 3 x 1.5mm2 3 x 1.5mm2 3 x 1.5mm2 3 x 1.5mm2
Power supply Wire Size - Outdoor 3 x 2.5mm2 3 x 2.5mm2 3 x 2.5mm2 3 x 2.5mm2 3 x 2.5mm2
Communication Wire 2 x 1mm2 2 x 1mm2 2 x 1mm2 2 x 1mm2 2 x 1mm2
Circuit Breaker Size 15A 20A 25A 15A 15A
OTHER
Tubing SizeGas mm/inch 12.7 / 1/2” 15.88 / 5/8” 15.88 / 5/8” 19.05/ 3/4” 19.05 / 3/4”
Liquid mm/inch 6.35 / 1/4” 9.52 / 3/8” 9.52 / 3/8” 9.52 / 3/8” 9.52 / 3/8”
Maximum Tubing Distance Length m 20 30 30 50 50
Maximum Height Difference Height m 15 15 20 30 30
WEIGHT
Indoor unit Nett kg 34 36 36 52 52
Outdoor unit Nett kg 37.5 51 62 110 110
INVERTERCooling & Heating
A B C D
CDA18I 800 286 530 546
CDA24I 890 320 670 632
CDA36I 900 320 790 600
CDA48I 940 368 1366 610
CDA60I 940 368 1366 610
A B C D E F G
EDA18I 890 790 295 202 592 290 852
EDA24I 890 790 295 202 592 290 852
EDA36I 890 790 295 202 592 290 852
EDA48I 1250 790 295 202 953 290 1212
EDA60I 1250 790 295 202 953 290 1212
![Page 10: Everywhere - Alpine Air](https://reader031.fdocuments.us/reader031/viewer/2022012223/61e07123efb44600a025f797/html5/thumbnails/10.jpg)
9 MINISPLIT RANGE 2018 CEILING / FLOOR
PRODUCT FEATURES > Elegant appearance > Ultra thin body > Flexible installation > Auto airflow control > Linear flow fan > High efficiency energy saving system> Long distance air throw > Dehumidification > Auto Restart
CEILING - FLOOR
Model No. Outdoor / Indoor FCA36/FEA36 FCA48/FEA48 FCA60/FEA60
Power supply 220-240V/1PH/50Hz 380-415V/3PH/50Hz
PERFORMANCE
CapacityCooling
BTU/h 36000 48000 60000W 10600 14000 17600
HeatingBTU/h 37500 53000 63500
W 10900 15500 18500
Noise Level (H/M/L)Indoor dB(A) 50 / 47 / 41 51 / 48 / 42 51 / 48 / 42
Outdoor dB(A) 60 62 62
Air Flow Volume (H/M/L) m3/h 1500 / 1200 / 1050 1800 / 1440 / 1260 1800 / 1440 / 1260
Suitable area m2 42 - 70 56 - 93 64 - 107
E.E.R. / C.O.P. w/w 2.81 / 3.34 2.87 / 3.02 3.08 / 3.10
POWER
Input powerCooling W 3520 4870 5710
Heating W 3450 5130 5970
Running CurrentCooling A 17 8.88 10.42
Heating A 16.5 9.33 10.83
Power supply Wire Size - Indoor - 3 x 1.5mm² 3 x 1.5mm²
Power supply Wire Size - Outdoor 3 x 2.5mm² 5 x 2.5mm² 5 x 2.5mm²
Communication Wire 3 x 2.5mm² + 2 x 1mm² 2 x 1mm² 2 x 1mm²
Circuit Breaker Size 25A 15A 15A
OTHER
Tubing SizeGas mm/inch 15.88 / 5/8” 19.05 / 3/4” 19.05 / 3/4”
Liquid mm/inch 9.52 / 3/8” 9.52 / 3/8” 9.52 / 3/8”
Maximum Tubing Distance Length m 50 50 50
Maximum Height Difference Height m 30 30 30
WEIGHT
Indoor unit Nett kg 33 44 44
Outdoor unit Nett kg 72 100 101
SPECIFICATIONS (E&OE)
Model No. Outdoor / Indoor FCA36I/FEA36I FCA48I/FEA48I FCA60I/FEA60I
Power supply 220-240V/1PH/50Hz 380-415V/3PH/50Hz
PERFORMANCE
CapacityCooling
BTU/h 36000 48000 60000W 10000 14000 16000
HeatingBTU/h 37500 51000 63000
W 11500 15500 18000
Noise Level (H/M/L)Indoor dB(A) 50 / 47 / 41 51 / 48 / 42 51 / 48 / 42
Outdoor dB(A) 60 56 56
Air Flow Volume (H/M/L) m3/h 1500 / 1200 / 1050 1800 / 1440 / 1260 1800 / 1440 / 1260
Suitable area m2 42 - 70 56 - 93 64 - 107
E.E.R. / C.O.P. w/w 3.24 / 3.63 3.26 / 3.69 3.21 / 3.64
POWER
Input powerCooling W 3086 4294 4984
Heating W 3168 4201 4945
Running CurrentCooling A 14.77 7.57 8.60
Heating A 15.16 7.45 8.42
Power supply Wire Size - Indoor 3 x 2.5mm² 3 x 1.5mm² 3 x 1.5mm²
Power supply Wire Size - Outdoor 3 x 2.5mm² 5 x 2.5mm² 5 x 2.5mm²
Communication Wire 2 x 1mm² 2 x 1mm² 2 x 1mm²
Circuit Breaker Size 25A 15A 15A
OTHER
Tubing SizeGas mm/inch 15.88 / 5/8” 19.05 / 3/4” 19.05 / 3/4”
Liquid mm/inch 9.52 / 3/8” 9.52 / 3/8” 9.52 / 3/8”
Maximum Tubing Distance Length m 30 50 50
Maximum Height Difference Height m 20 30 30
WEIGHT
Indoor unit Nett kg 33 44 44
Outdoor unit Nett kg 62 110 110
SPECIFICATIONS (E&OE)
A B C D E
FEA36 / FEA36I
1280 205 660 245 1192
FEA48 / FEA48I
1631 205 660 245 1543
FEA60 / FEA60I
1631 205 660 245 1543
A B C D
FCA36I 900 320 790 600
FCA48I 940 368 1366 610
FCA60I 940 368 1366 610
A B C D
FCA36 903 354 857 606
FCA48 945 340 1255 585
FCA60 945 340 1255 585
ON - OFFCooling & Heating
INVERTERCooling & Heating
ON - OFF / INVERTER
ON - OFF
INVERTER
![Page 11: Everywhere - Alpine Air](https://reader031.fdocuments.us/reader031/viewer/2022012223/61e07123efb44600a025f797/html5/thumbnails/11.jpg)
ACCESSORIES 10
CEILING - FLOOR ACCESSORIESAIR CURTAINS
EVAPORATIVE COOLER
CONDENSATE PUMP
Model No. FM-1209N-2Y FM-1212N-2Y FM-1215N-2Y
Power Supply 220-230V/1PH/50Hz
Power W 150 180 220
Air Velocity m/s 11
Air Volume m3/h 1200 1700 2100
Air Flow Throw (Max) m 3 3 3
Noise Level dB 45 47 47
Length mm 900 1200 1500
Installation Height m 3.0 - 3.5 3.0 - 3.5 3.0 - 3.5
Weight kg 12.8 15.7 19.9
Model No. 18AP9 - TRIAC (1Ph)
Power Supply 220-240V/1PH/50Hz
Fan Speed 16
Power W 1100
Air Flow m3/h 18000
Air Pressure Pa 180
Fan Type Axial Fan
Control Type TRIAC
Water Consumption l/h 15 - 20
Filter Type Honeycomb 5090
Filter Size (W x H x D) mm 770 x 655 x 100
Effective Area m2 120 - 150
Noise dB 73
Weight kg 75
900 195
220
1200 195
220
1500 195
220
1100
1600
675
900x500
900
Horizontal Angle≥ 35o
Reducing Elbow675x675 / 900x500
Ø12 Wall BoltsØ8 Bolt and Welding
Window
WallSoft Canvas Connection
L = 150 ~ 200mm
Model No. ECP 1A - OEM 15 L/h
Power Supply 220-230V/1PH/50Hz
Power W 50
Ambient Temperature oC 0 - 45
Noise Level dB 20
Max. Flow Rate l/h 15
Max. Pumping Head m 12
Max. Suction Head m 2
Max. Head Horizontal Distance m 30
Max. Water Temperature oC 45
Maximum flow rate
1514131211109876543210 0 5 10
Horizontal distance in meters
Lite
rs p
er h
our
15 20 25 30
Pump 15 L/h
.Pumping head = 0 m
.Pumping head = 1 m
.Pumping head = 2 m
.Pumping head = 3 m
.Pumping head = 4 m
.Pumping head = 5 m
![Page 12: Everywhere - Alpine Air](https://reader031.fdocuments.us/reader031/viewer/2022012223/61e07123efb44600a025f797/html5/thumbnails/12.jpg)
INSTALLATION TIP11
ECO AIRE WOULD LIKE TO GIVE YOU THE FOLLOWING GUIDELINES WHICH WILL ENSURE PROPER INSTALLATION OF THE UNIT.
• The maximum height difference between the indoor and outdoor units is 10m.
• No 90˚ degree elbows are allowed on the connection pipes. Only long radius elbows and they need to be minimised as far as possible.
• If the height difference between the indoor and outdoor units is over 5m, you have to install an oil trap at every 4m.
• When the outdoor unit is above the indoor unit, please refer to Fig 1 for pipe layout.
• When the outdoor and indoor units are at the same height, please refer to Fig 2.
• If the unit is used for high sensible load areas e.g. computer room etc. a condenser fan speed control must be installed.
• Please ensure that the voltage on a 220V unit does not drop below 200V at start-up of the compressor.
• Please follow Eco Aire’s commissioning checklist.
• Please notify end-user not to leave the doors and windows open for extended periods.
• Liquid and gas pipes to be insulated separately.
• Drain pipe must always run at the lowest level, see Fig 3.
• When drilling a hole through the wall, the hole must always slope to the outside to allow free flow of water to the drain, see Fig 3.
• The refrigerant and oil charge inside the unit is sufficient for a 5m connection pipe. If the pipe length is longer, both refrigerant and oil needs to be added, see table.
• For R410A please ensure that only Polyester oil is used. Keep in mind that this oil is highly hydroscopic. Therefore only a new container can be used and the system needs to be evacuated within 20 minutes from adding the oil, for at least 24 hours. Failure to do so can cause moisture in the system and failure due to high acid content.
Liquid RingFIG.1
FIG.3
Standard Pipe Length
Maximum Pipe Length
Maximum Pipe Height
Additional Refrigerant
Charge
Additional Oil Charge
m m m m ml/m
9000 BTU 5 20 15 30 1
12000 BTU 5 20 15 30 1.6
18000 BTU 5 20 15 60 1.6
24000 BTU 5 30 15 60 2.4
24000 BTU 5 30 15 60 3.4
36000 BTU 5 30 15 60 4
48000 BTU 7.5 50 30 60 5
60000 BTU 7.5 50 30 60 5.5
FIG.2
INSTALLATION TIPS
![Page 13: Everywhere - Alpine Air](https://reader031.fdocuments.us/reader031/viewer/2022012223/61e07123efb44600a025f797/html5/thumbnails/13.jpg)
…for you!Everywhere
2007
2008
2008
2012
2013
2014
2014
2014
2014
2014
2014
2017
2017
SHOPPING MALLSZevenwacht Mall
V & A Marina Waterfront
Waterstone-C.T.
Cradlestone
The Grove
Canary Walk-Nelspruit
Mall of the South
Northgate Mall
Soshanguve Crossing
Thaba Mall
Watercrest Mall
Broadwalk-Richards Bay
Cornubia
HOTELS &ENTERTAINMENT
2007
2007
2011
2013
2014
2015
2015
2015
2016
2016
2016
One & Only-C.T.
Grand West Casino-C.T.
Tusk Casino-Empangeni
Westcliff - JHB
Radisson Hotel-P.E.
Emperor’s Palace
Gold Reef City Casino-JHB
Radisson Blu Sandton
Kyalami Pit Complex
Ster Kinekor Vaal Mall
Time Square Casino
EDUCATIONALWestville University
Univ. of PTA-Eng. Dept.
Univ. of PTA-Prinshof
UNISA Florida
Univ. of Jhb - Bunting Road
Thuto Building Mangosuthu Technikon
Teachers Training Soshanguve
2011
2011/2013
2014
2014
2014
2016
2017
HOSPITALS
2006
2007
2008
2009
2010/2015
2011
2011
2011
2012
2012
2014
2016
2016
3 Military Hospital
N1 City Hospital
Vryburg Hospital
Addington Hospital
Civitas Pretoria
Mokopane Hospital
Natalspruit Hospital
Panorama Mediclinic
Highveld Eye Hospital
Military Health Base
Netcare Pinehaven
Albert Luthuli-Academic Hospital
CDLV Day Hospital
PUBLIC BUILDINGS
2013
2014
2013
2014
2014
2015
2010
2014
2015
2016
2016
2015
2015
Alice Lane Offices
Choose Life Church
Toyota Midrand
CTM & Italtile
Porche Head Office-Pretoria
CSIR
BMW Showroom Pretoria
Anglo American
Anslow Park
Council Chambers
Tsonga Magistrate Court
MiWay Insurance
Development Bank of S.A.
SPECIAL PHARMACEUTICAL SITES
2009
2014
2013
2014
2014
2014/2016
Middelburg Pharmacy
Plascon Test Laboratory
Lea Glen Pharmacy
Phokeng Pathology
Covidien Pharmaceuticals
Medtronic Covidien
BRANCHES
GoldfieldsAndré van NiekerkT 082 772 0035E [email protected]
Garden RouteHeine LateganT 072 533 6747E [email protected]
BloemfonteinSusan BonthuysT 082 578 7124E [email protected]
KwaZulu NatalStrath RowlandT 031 701 6114E [email protected]
JohannesburgT 011 397 2162E [email protected] 24 Patrick Road, Jetpark, SA
Cape TownBradley MaraisT 079 522 0724E [email protected]
HEAD OFFICE
Port ElizabethDale PayT 074 662 1111E [email protected]
WHAT YOU NEED WHERE YOU NEED IT TECHNICAL SUPPORT EXCELLENT VALUE