Evaluation of non-US Experience: A Pilot Project on …Evaluation of non-US Experience.ppt R0 vgs...
Transcript of Evaluation of non-US Experience: A Pilot Project on …Evaluation of non-US Experience.ppt R0 vgs...
![Page 1: Evaluation of non-US Experience: A Pilot Project on …Evaluation of non-US Experience.ppt R0 vgs 11/6/02 Pg 2 Background • The ACR-700 is an evolutionary extension of the proven](https://reader035.fdocuments.us/reader035/viewer/2022081613/5fbdcaf82a5a4d4d9a5de2c6/html5/thumbnails/1.jpg)
Pg 111/6/02Evaluation of non-US Experience.ppt R0 vgs
Evaluation of non-USExperience:
A Pilot Project on ACR
Dr. V.G. SnellDirector, Safety and Licensing, ACR
![Page 2: Evaluation of non-US Experience: A Pilot Project on …Evaluation of non-US Experience.ppt R0 vgs 11/6/02 Pg 2 Background • The ACR-700 is an evolutionary extension of the proven](https://reader035.fdocuments.us/reader035/viewer/2022081613/5fbdcaf82a5a4d4d9a5de2c6/html5/thumbnails/2.jpg)
Pg 211/6/02Evaluation of non-US Experience.ppt R0 vgs
Background
• The ACR-700 is an evolutionary extension of theproven CANDU 6, which has eight units in operation onfour continents, two units currently under construction,and one which went critical in September 2002
![Page 3: Evaluation of non-US Experience: A Pilot Project on …Evaluation of non-US Experience.ppt R0 vgs 11/6/02 Pg 2 Background • The ACR-700 is an evolutionary extension of the proven](https://reader035.fdocuments.us/reader035/viewer/2022081613/5fbdcaf82a5a4d4d9a5de2c6/html5/thumbnails/3.jpg)
Pg 311/6/02Evaluation of non-US Experience.ppt R0 vgs
Design Summary• Light water coolant• Slightly enriched fuel• Heavy water moderator• Horizontal pressure tubes as the
core pressure boundary• Each channel connects via a
small inlet and outlet feeder pipeto headers above the core
• 4 pumps, 2 steam generatorsabove the core− similar to PWRs
![Page 4: Evaluation of non-US Experience: A Pilot Project on …Evaluation of non-US Experience.ppt R0 vgs 11/6/02 Pg 2 Background • The ACR-700 is an evolutionary extension of the proven](https://reader035.fdocuments.us/reader035/viewer/2022081613/5fbdcaf82a5a4d4d9a5de2c6/html5/thumbnails/4.jpg)
Pg 411/6/02Evaluation of non-US Experience.ppt R0 vgs
Maturity• CANDU is a mature technology licensed and operating in Canada,
Argentina, South Korea, Romania, & China• Supported by ~50 years of R&D• Regulators in these countries have performed independent
reviews to determine acceptability− have used, reviewed and largely applied Canadian experience
• ACR represents an evolution, not a revolution− Most of the CANDU technology base applies− Modest extensions to code validation envelope + component tests
![Page 5: Evaluation of non-US Experience: A Pilot Project on …Evaluation of non-US Experience.ppt R0 vgs 11/6/02 Pg 2 Background • The ACR-700 is an evolutionary extension of the proven](https://reader035.fdocuments.us/reader035/viewer/2022081613/5fbdcaf82a5a4d4d9a5de2c6/html5/thumbnails/5.jpg)
Pg 511/6/02Evaluation of non-US Experience.ppt R0 vgs
ACR Regulatory Status
• U.S. – pre-application review underway with intent tosubmit application for Standard Design Certificationand/or COL
• Canada – pre-licensing review with Canadian NuclearSafety Commission (CNSC) underway
• U.K. – possibility of pre-licensing review by NuclearInstallations Inspectorate (NII) under discussion
• Initial three-regulator meeting held to explore co-operation
![Page 6: Evaluation of non-US Experience: A Pilot Project on …Evaluation of non-US Experience.ppt R0 vgs 11/6/02 Pg 2 Background • The ACR-700 is an evolutionary extension of the proven](https://reader035.fdocuments.us/reader035/viewer/2022081613/5fbdcaf82a5a4d4d9a5de2c6/html5/thumbnails/6.jpg)
Pg 611/6/02Evaluation of non-US Experience.ppt R0 vgs
Licensing Opportunity• AECL recognizes that each regulator is responsible for licensing
ACR in its own country• Need some mechanism to use the existing R&D and licensing
experience to date so that current licensing reviews make bestuse of available resources and information
• Need to demonstrate flexibility in regulatory approach to non-UStechnology so US can benefit from its introduction
• Need to show that safety intent of the USNRC requirements ismet without requiring line-by-line compliance
• Result: Enhance effectiveness of US regulatory review
![Page 7: Evaluation of non-US Experience: A Pilot Project on …Evaluation of non-US Experience.ppt R0 vgs 11/6/02 Pg 2 Background • The ACR-700 is an evolutionary extension of the proven](https://reader035.fdocuments.us/reader035/viewer/2022081613/5fbdcaf82a5a4d4d9a5de2c6/html5/thumbnails/7.jpg)
Pg 711/6/02Evaluation of non-US Experience.ppt R0 vgs
Pilot Project
• Pilot project proposed to see how US could use &incorporate non-US experience as a basis for NRCregulatory acceptance
• Scope must be complex enough to be a meaningfultest, but limited so it can be shown to work in areasonable time frame
![Page 8: Evaluation of non-US Experience: A Pilot Project on …Evaluation of non-US Experience.ppt R0 vgs 11/6/02 Pg 2 Background • The ACR-700 is an evolutionary extension of the proven](https://reader035.fdocuments.us/reader035/viewer/2022081613/5fbdcaf82a5a4d4d9a5de2c6/html5/thumbnails/8.jpg)
Pg 811/6/02Evaluation of non-US Experience.ppt R0 vgs
Specific Proposal• Like LWR, CANDU has a main-line system thermohydraulics code
for transients & accidents (CATHENA)− Full two-fluid one-dimensional network transient model− Integrated plant controllers− Detailed fuel, fuel channel models at high temperature
• Extensively validated against tests in full-scale fuel channels andfull-height CANDU system thermohydraulic loops (RD14, RD14M)
• Used in licensing analysis for CANDU 6 in Canada, China, Korea,Romania
• Determine basis for NRC agreement that code and supportingvalidation is acceptable for use in US licensing of ACR
• Restrict to system thermohydraulics portion for pilot project
![Page 9: Evaluation of non-US Experience: A Pilot Project on …Evaluation of non-US Experience.ppt R0 vgs 11/6/02 Pg 2 Background • The ACR-700 is an evolutionary extension of the proven](https://reader035.fdocuments.us/reader035/viewer/2022081613/5fbdcaf82a5a4d4d9a5de2c6/html5/thumbnails/9.jpg)
Pg 911/6/02Evaluation of non-US Experience.ppt R0 vgs
ScopeIndependent review of the technical thoroughness and
completeness of the formal validation process• Technical comparison to the validation methods
required by the NRC for computer codes used in LWRsafety analysis and/or to generally accepted practice
• Gap analysis between the CANDU methods and thosedeveloped to validate LWR safety analysis codes
• Recommendations on how to close significant gaps, ifany
• Overall: independent judgement as to the technicaladequacy of the formal validation & verification of theCATHENA computer code
![Page 10: Evaluation of non-US Experience: A Pilot Project on …Evaluation of non-US Experience.ppt R0 vgs 11/6/02 Pg 2 Background • The ACR-700 is an evolutionary extension of the proven](https://reader035.fdocuments.us/reader035/viewer/2022081613/5fbdcaf82a5a4d4d9a5de2c6/html5/thumbnails/10.jpg)
Pg 1011/6/02Evaluation of non-US Experience.ppt R0 vgs
Report
• Independent report would be submitted to the NRC forreview and concurrence as part of pre-applicationreview
• AECL would commit to the timely completion of thework to address the gaps, identified in the report, thatthe NRC considers technically significant− i.e., which would preclude NRC acceptance of the use in the
US of the CATHENA computer code for ACR safety analysis• NRC would issue SER on the results of their review
![Page 11: Evaluation of non-US Experience: A Pilot Project on …Evaluation of non-US Experience.ppt R0 vgs 11/6/02 Pg 2 Background • The ACR-700 is an evolutionary extension of the proven](https://reader035.fdocuments.us/reader035/viewer/2022081613/5fbdcaf82a5a4d4d9a5de2c6/html5/thumbnails/11.jpg)
Pg 1111/6/02Evaluation of non-US Experience.ppt R0 vgs
Independence
• Propose to use US National Lab. (or NRC-recommended alternative) to perform initial review− Allows flexibility in interpretation of requirements, use of
international experience− Supports DOE policy of facilitating introduction of non-US
technology− Creates US expertise for use in further CANDU work
• NRC, DOE, the US lab. and AECL would discuss theterms of reference for the review to ensure that it iswell understood and appropriately focussed prior tothe lab commencing the work
![Page 12: Evaluation of non-US Experience: A Pilot Project on …Evaluation of non-US Experience.ppt R0 vgs 11/6/02 Pg 2 Background • The ACR-700 is an evolutionary extension of the proven](https://reader035.fdocuments.us/reader035/viewer/2022081613/5fbdcaf82a5a4d4d9a5de2c6/html5/thumbnails/12.jpg)
Pg 1211/6/02Evaluation of non-US Experience.ppt R0 vgs
Schedule
• Estimate about 4 months for report from Lab.
![Page 13: Evaluation of non-US Experience: A Pilot Project on …Evaluation of non-US Experience.ppt R0 vgs 11/6/02 Pg 2 Background • The ACR-700 is an evolutionary extension of the proven](https://reader035.fdocuments.us/reader035/viewer/2022081613/5fbdcaf82a5a4d4d9a5de2c6/html5/thumbnails/13.jpg)
Pg 1311/6/02Evaluation of non-US Experience.ppt R0 vgs
Next Steps
• (Verbal) agreement in principle from NRC• AECL to approach DOE plus National Lab or alternative• Finalize terms of reference• Advise ACRS (?)• Start work
![Page 14: Evaluation of non-US Experience: A Pilot Project on …Evaluation of non-US Experience.ppt R0 vgs 11/6/02 Pg 2 Background • The ACR-700 is an evolutionary extension of the proven](https://reader035.fdocuments.us/reader035/viewer/2022081613/5fbdcaf82a5a4d4d9a5de2c6/html5/thumbnails/14.jpg)
Pg 1411/6/02Evaluation of non-US Experience.ppt R0 vgs