Euroclad Vieo H Wall Coverover Timber

14
Ply/Timber/OSB facing by Others in accordance with relevent standards. 454mm Nominal 27 Nominal Standard offer is 454mm profile. Also available on request in other widths from 225mm to 517mm. SCALE: NTS (To be read in conjunction with Vieo system specification documents) Euro Clad Ltd, Wentloog Corporate Park, Wentloog Road, Cardiff CF3 2ER Tel: (+44) 029 20 790722, Fax: (+44) 029 20 793149 Website: www.vieoroof.com This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property. Drawn by: PCl Checked by: JP ISSUE DATE: June 2014 TITLE: Vieo Horizontal Wall Covering (On Ply or OSB) DWG NO: V10_HWC_TD_System

description

Euroclad_ Vieo Horizontal Wall Covering System over Timber Facing.pdf

Transcript of Euroclad Vieo H Wall Coverover Timber

Ply/Timber/OSB facing

by Others in accordance

with relevent standards.

454m

m N

om

inal

27

Nom

inal

Standard offer is 454mm profile.

Also available on request in other widths from 225mm to 517mm.

SCALE: NTS

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: PCl Checked by: JPISSUE DATE: June 2014

TITLE: Vieo Horizontal Wall Covering (On Ply or OSB)

DWG NO: V10_HWC_TD_System

COLOUR SIDE

Elite Breather

Membrane

Vieo_25_454 Profile

Ply/Timber/OSB facing

by Others in accordance

with relevent standards.

Vieo Sheet Seaming Sequence

"Stage 2 Seam" (Aluminium Material Only)

Elite Roof Breather

Vieo Sliding Clip

"Stage 1 Seam"

SCALE: NTS

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: PCl Checked by: JPISSUE DATE: June 2014

TITLE: Vieo Horizontal Wall Covering (On Ply or OSB)

DWG NO: V10_HWC_TD_System

CLIP TYPICAL CENTRES:

DETERMINED BY PROJECT WIND SUCTION LOADS AS FOLLOWS:

1260mm for loads up to 1.5kN/M²

660mm for loads 1.5 to 2.0kN/M²

300mm for loads 2 to 4kN/M²

Where substrate is Min 18mm ply or Min 15mm OSB 3

TYPICAL ARRANGEMENT: 1260mm IN CENTRAL AREAS,

REDUCE CLIP CENTRES AT CORNERS AND IN HIGH LOAD AREAS.

CHECK SYSTEM CAPACITY AGAINST PROJECT LOADS AND ADJUST IF NECESSARY

SCALE: NTS

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: PCl Checked by: JPISSUE DATE: June 2014

TITLE: Vieo Horizontal Wall Covering (On Ply or OSB)

DWG NO: V10_HWC_TD_System

Movement allowed under flashings.

Closure with flashing fixed to decking and not through sheet.

Maximum 75mm

* Allow clearance for anticipated

movement between support Closure, end

of Vieo sheet & Ridge Closure

*

Flashing fixed to inverted Ridge Closure

(Appropriate where expansion allowance

up to 30mm is required)

Maximum allowable to

next Vieo clip 300mm

#

# end of Vieo sheet must fall under

downslope edge of inverted Closure

Maximum allowable distance to next Vieo clip 300mm from closure fixing

Cover flashings fixed to structure and Vieo Closure

Appropriate where expansion

allowance of Max 10mm required

SCALE: NTS

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: PCl Checked by: JPISSUE DATE: June 2014

TITLE: Vieo Horizontal Wall Covering (On Ply or OSB)

DWG NO: V10_HWC_TD_System

Assembled Front View

Create fixed point using clip with additional fixing.

Max sheet length recommended 20M.

To divide expansion clearance required create fixed point in

middle of sheet.

Fixed Point

Expansion allowance under flashing

Tophat flashing vertical joint

Assembled Front View

Create fixed point using clip with additional fixing.

Max sheet length recommended 20M.

To divide expansion clearance required create fixed point in

middle of sheet.

SCALE: NTS

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: PCl Checked by: JPISSUE DATE: June 2014

TITLE: Vieo Horizontal Wall Covering (On Ply or OSB)

DWG NO: V10_HWC_TD_System

Use alternative flashing fixed to inverted

Closure Detail where expansion allowance

>10mm is required)

Alternative Insert for inverted Tophat

SCALE: NTS

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: PCl Checked by: JPISSUE DATE: June 2014

TITLE: Vieo Horizontal Wall Covering (On Ply or OSB)

DWG NO: V10_HWC_TD_System

Vieo Sheet

Breather Membrane

Flashing rivetted to closure

@ 600mm centres

SCALE: NTS

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: PCl Checked by: JPISSUE DATE: June 2014

TITLE: Vieo Horizontal Wall Covering (On Ply or OSB)

DWG NO: V10_HWC_TD_System

Vieo Closure

At gable ends it is normally necessary to use

rake cut sheets with bespoke length fillers

and closure sections. In some cases it may be

possible to detail tapered sheets or flashings.

Flashing as drip under roof

or dressed over as verge.

SCALE: NTS

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: PCl Checked by: JPISSUE DATE: June 2014

TITLE: Vieo Horizontal Wall Covering (On Ply or OSB)

DWG NO: V10_HWC_TD_System

Sheet seamed to clip

Vieo closure

Cill flashing (with optional fall).

Jamb flashing

Notch bottom corner out of Jamb & Cill flashings on site.

Jamb flashing extends over face of Cill.

Drip Flashing over Jambs.

Site folded stopend formed

by cut and fold back.

HEAD DETAIL

CILL DETAIL

SCALE: NTS

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: PCl Checked by: JPISSUE DATE: June 2014

TITLE: Vieo Horizontal Wall Covering (On Ply or OSB)

DWG NO: V10_HWC_TD_System

JAMB DETAIL

Jamb flashing

Cill flashing

SCALE: NTS

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: PCl Checked by: JPISSUE DATE: June 2014

TITLE: Vieo Horizontal Wall Covering (On Ply or OSB)

DWG NO: V10_HWC_TD_System

Small notch into Vieo sheet

to receive drip. Sealed with

mastic

Site folded stopend on drip

Notch corner out of Cill

flashing on site

Jamb flashing over face of Cill

Design Window Module & Vieo sheet

to be in line. Either by using multiples

of 454mm or adjustment of Vieo sheet

coverwidth.

SCALE: NTS

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: PCl Checked by: JPISSUE DATE: June 2014

TITLE: Vieo Horizontal Wall Covering (On Ply or OSB)

DWG NO: V10_HWC_TD_System

J clip used to secure

free edge of cut sheet

Drip Flashing over Jambs.

Site folded stopend formed

by cut and fold back.

Vieo closure

Cill flashing (with optional fall)

Jamb flashing

Notch bottom corner out of Jamb & Cill flashings on site.

Jamb flashing extends over face of Cill.

Angle fitted prior to offering to structure

HEAD DETAIL

CILL DETAIL

SCALE: NTS

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: PCl Checked by: JPISSUE DATE: June 2014

TITLE: Vieo Horizontal Wall Covering (On Ply or OSB)

DWG NO: V10_HWC_TD_System

Jamb flashing

Cill flashing

JAMB DETAIL

SCALE: NTS

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: PCl Checked by: JPISSUE DATE: June 2014

TITLE: Vieo Horizontal Wall Covering (On Ply or OSB)

DWG NO: V10_HWC_TD_System

Vieo Sheet

Breather Membrane

Flashing fixed to back to ply

Site folded stopend also formed

by cut and fold back.

Ply/Timber/OSB facing

by Others in accordance

with relevent standards.

SCALE: NTS

(To be read in conjunction with Vieo

system specification documents)

Euro Clad Ltd,

Wentloog Corporate Park,

Wentloog Road, Cardiff CF3 2ER

Tel: (+44) 029 20 790722,

Fax: (+44) 029 20 793149

Website: www.vieoroof.com

This draft drawing has been supplied by Euro Clad Ltd for the purpose of guidance free of charge.It is a suggested typical detail and as such should not be assumed suitable for any specific

project or application.No responsibility is assumed for errors or misinterpretations resulting from the information contained in the drawing.Details are for illustration only and no liability is

accepted. We reserve the right to change the details without notice.The drawing is copyright, it remians our property.

Drawn by: PCl Checked by: JPISSUE DATE: June 2014

TITLE: Vieo Horizontal Wall Covering (On Ply or OSB)

DWG NO: V10_HWC_TD_System