EuCARD-2 WP12 HZDR 16-17.04.2014

8
Rong Xiang I [email protected] I www.hzdr.de EuCARD-2 WP12 HZDR 16-17.04.2014

description

EuCARD-2 WP12 HZDR 16-17.04.2014. Sub-task 12.5.1: Pb photocathode deposition. Work package 12 – Task 12.5 photocathodes - Subtasks 12.5.1: Pb photocathode deposition & 12.5.2: Diamond a mplifier c athode (DAC) development - PowerPoint PPT Presentation

Transcript of EuCARD-2 WP12 HZDR 16-17.04.2014

Page 1: EuCARD-2 WP12 HZDR 16-17.04.2014

Rong Xiang I [email protected] I www.hzdr.de

EuCARD-2 WP12

HZDR

16-17.04.2014

Page 2: EuCARD-2 WP12 HZDR 16-17.04.2014

Seite 2 Mitglied der Helmholtz-GemeinschaftJochen Teichert [email protected] www.hzdr.de HZDR

2013 2014 2015 2016 17/1

2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1

Deliverables D12.8NCBJ

D12.9HZDR

D12.13HZB

Milestones MS75NCBJ

MS80NCBJ

Work package 12 – Task 12.5 photocathodes - Subtasks 12.5.1: Pb photocathode deposition & 12.5.2: Diamond amplifier cathode (DAC) developmentInvolved Institues: NCBJ Swierk, DESY Hamburg, HZB Berlin, HZDR Dresden

project start: May 1, 2013

D12.9 Pb/Nb plug photocathode measurements and characterization. Reportdetailing the verification of Pb/Nb plug photocathode performance at the HZDRinjector test facility

Sub-task 12.5.1: Pb photocathode deposition

Page 3: EuCARD-2 WP12 HZDR 16-17.04.2014

Seite 3 Mitglied der Helmholtz-GemeinschaftJochen Teichert [email protected] www.hzdr.de HZDR

3

Sub-task 12.5.2: Diamond Amplifier Cathode Development

project start: May 1, 2013

2013 2014 2015 2016 17/1

2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1

Deliverables D12.8NCBJ

D12.9HZDR

D12.13HZB

Milestones MS75NCBJ

MS80NCBJ

D12.13 results of DAC implementation in SRF guns: Report detailing the performance verification of DAC photocathode cells at BNL and BESSY-II, defining implementation process into SRF gun structure.

Collaboration of HZB and HZDR

Page 4: EuCARD-2 WP12 HZDR 16-17.04.2014

Rong Xiang I [email protected] I www.hzdr.de Member of the Helmholtz AssociationPage 4

ELBE SRF-Gun.2 statusSRF Gun.2 will be moved in accelerator hall during the Easter-Shutdown.

⇒ Bz,max = 449 mT (@10A)

H.Vennekate, DPG2014

0.0 10.0M 20.0M 30.0M 40.0M 50.0M109

1011

Test#4 (May 3, 2011) after mech. grinding an re-treatment Test#9 (Feb 13, 2012) after helium vessel welding Test#13 (May 23, 2013) after HPR retreatment Q0 limit corresponding to a refrigerator power of 30 W reference measurement of operating SRF gun

Epk [V/m]

qual

ity fa

ctor

, Q0

1010

new cavity

old cavity

SC solenoid

Page 5: EuCARD-2 WP12 HZDR 16-17.04.2014

Rong Xiang I [email protected] I www.hzdr.de Member of the Helmholtz AssociationPage 5

• Made of pure niobium rod, 2-types (puck, plug)• Polishing with diamond suspension, mean roughness 24 nm• Clean with iso-propanol in ultrasonic bath• blow with ionized N2 till particle free, packed in dry N2

Nb-Samples

Puck form with Ø10mm Shipped back after coatingMirror like surface

Page 6: EuCARD-2 WP12 HZDR 16-17.04.2014

Rong Xiang I [email protected] I www.hzdr.de Member of the Helmholtz AssociationPage 6

Experimental setupVacuum system: chamber and pumps, gauge, sample holder, anode, feed through, UV optical windowLaser system: high intensity UV laser, scanner, power meter/diode measurement instruments: Keithley 6485, DC, power meter

Test chamber

Anode

cathode

Page 7: EuCARD-2 WP12 HZDR 16-17.04.2014

Rong Xiang I [email protected] I www.hzdr.de Member of the Helmholtz AssociationPage 7

• UV 258 nm• 100 -500 kHz adjustable• Intensity adjustable, < 0.3 mJ/cm2

• High power cleaning• Low power for QE measurement

UV laser for sample cleaning

Intensity profile of the UV output [I.Will, FEL06]

Two channel laser for ELBE SRF Gun

Page 8: EuCARD-2 WP12 HZDR 16-17.04.2014

Rong Xiang I [email protected] I www.hzdr.de Member of the Helmholtz AssociationPage 8

Plan of experiments

1. cleaning with high intensity UV laser2. QE measurement3. field emission measurement in HZB