EU sewage and waste water pumps - technical data dp-pumps

32
Technical data 50Hz DIN/IEC Drainage and sewage pumps Series: DVV, DRV, DRS & DRSK

description

 

Transcript of EU sewage and waste water pumps - technical data dp-pumps

Page 1: EU sewage and waste water pumps - technical data dp-pumps

Technical data 50Hz DIN/IECDrainage and sewage pumps

Series: DVV, DRV, DRS & DRSK

Page 2: EU sewage and waste water pumps - technical data dp-pumps

2

Table of Contents

1 Introduction1.1 General .................................................................................................................................................. 31.2 Application ............................................................................................................................................. 31.3 Working range........................................................................................................................................ 31.4 Materials ................................................................................................................................................ 31.5 Motor...................................................................................................................................................... 31.6 Features................................................................................................................................................. 31.7 Impeller types......................................................................................................................................... 41.8 Material conversion................................................................................................................................ 41.9 Model key............................................................................................................................................... 5

2 Specifications2.1 DVV 3/4.................................................................................................................................................. 62.2 DVV 7..................................................................................................................................................... 72.3 DVV 7 K ................................................................................................................................................. 82.4 DVV 7 IN K............................................................................................................................................. 92.5 DVV 7 O K ........................................................................................................................................... 102.6 DVV 7 VD..............................................................................................................................................112.7 DVV 10................................................................................................................................................. 122.8 DVV 27................................................................................................................................................. 132.9 DRV 6 100-110..................................................................................................................................... 142.10 DRV 6 120-130 .................................................................................................................................... 152.11 DRV 8 110-120..................................................................................................................................... 162.12 DRV 8 130 ........................................................................................................................................... 172.13 DRV 9 .................................................................................................................................................. 182.14 DRV 11................................................................................................................................................. 192.15 DRV 12 ................................................................................................................................................ 202.16 DRV 13 ................................................................................................................................................ 212.17 DRV 24 ................................................................................................................................................ 222.18 DRV 27 ................................................................................................................................................ 232.19 DRSK 21 .............................................................................................................................................. 242.20 DRSK 31 .............................................................................................................................................. 252.21 DRS 3, 1x230V .................................................................................................................................... 262.22 DRS 3, 3x400V .................................................................................................................................... 272.23 DRS 4 .................................................................................................................................................. 282.24 DRS 6 .................................................................................................................................................. 29

Page 3: EU sewage and waste water pumps - technical data dp-pumps

3

1 Introduction

1.1 General

The drainage and sewage pump ranges DVV, DRV, DRK and DRS are a complete range of submersible pumps for multiple types of water transport.

1.2 Application

The pump series have the following main applications:- water drainage- tunnel wastewater drainage- wastewater and sewage sump pit- light industrial, commercial and residential applications- agriculture water supply and drainage-water supply for irrigation systems

1.3 Working range

The ranges have the following working range:

1.4 Materials

In general the range have the following material, see per pump type the detailed materials:

1.5 Motor

1.6 Features

Construction:- Robust pump construction with hardened shaft for long lasting operation- double mechanical seal in oil chamber

DVV

Max. medium temperature [°C] 40 (range 7&10)50 (range 3, 4 & 27)

Maximum head [mWk] 25

Maximum capacity [m3/h] 130

Pressure range PN2,5 up to PN16

DRV

Max. medium temperature [°C] 40 (range 6)55 (other ranges)

Maximum head [mWk] 27

Maximum capacity [m3/h] 155

Pressure range PN6 up to PN16

DRS(K)

Max. medium temperature [°C] 40 (range 3)55 (other ranges)

Maximum head [mWk] 49,5

Maximum capacity [m3/h] 190

Pressure range PN6 up to PN16

pump casing Impeller Shaft motor housing

JL 1040 JL 1040 1.4021 JL 1040

Item Description

Power range 0,18kW up to 7,5kW

Voltage 1x230V or 3x400V

Frequency 50Hz

No of poles 2P or 4P, see ranges

Insulation IP68

Safety Build in thermal protection

Cable length 3m (range DVV3 WS)10m (all other ranges)

Connection DOL <=4kW, 5,5kW and bigger S/D

Sealing Double mechanical seal

Page 4: EU sewage and waste water pumps - technical data dp-pumps

4

1.7 Impeller types

The range DVV, DRV, DRS en DRSK has four impeller types, depending on series, see tables below.

1.8 Material conversion

The table below shows the different standard for the used materials in the ranges

Cutter impeller

Self cleaning componentsHigh efficiencyHigh abrasion resistanceHigh pressureCutting of many different kind of solids

Vortex impeller

Limited free passage Relative high efficiencyApplicable for waste water containing small solids

Open diagonal vane impeller

Large free passageNon cloggingHigh abrasion resistanceTransport of waste water containing solids andfibre particles

Material Description DIN standard Code Standard ASTM

JL 1030 Cast Iron GG20 GJL-200 EN 1561 A48:25B

JL 1040 Cast Iron GG25 GJS-250 EN 1561 A48:40B

1.4021 Chromium steel 1.4021 X20Cr13 EN 10088 A276:420

1.4028 Chromium steel 1.4028 X30CR13 EN 10088 A276:410

1.4301 Chromium-nickel steel 1.4301 X5CrNi 18-10 EN 10088 A276:304

1.4404 Chromium-nickel-molybdenum steel 1.4404 X2CrNiMo 17-12-2 EN 10088 A276:316L

1.4408 Chromium-nickel-molybdenum cast steel 1.4408 GX5CrNiMo 19-11-2 EN 10088 A743CF8M

1.4571 Chromium-nickel-molybdenum titanium steel 1.4571 X6CrNrMoTi17-12-2 En 1088 A276:316Ti

PA Polyamide (35%glass fibre) PA

PP0 GF20 Polyphenylene oxide (20% glass fibre) Noryl

PP GF30 Polypropylene (30% glass fibre) PP GF30

Page 5: EU sewage and waste water pumps - technical data dp-pumps

5

1.9 Model key

The pumps are designated as according to the following tableTable 1: Explanation of installation name

Dui

jve

laar

V (

=D

rain

age)

R (

=S

ewag

e)C

utte

rV

orte

xO

pen

diag

ona

l sin

gle

van

e

Nom

inal

cap

acity

[l/s

]

Pow

er (

kWx1

0)

Num

ber

of p

oles

1

Sin

gle

phas

e

With

floa

t sw

itch

With

sep

arat

e flo

at s

witc

h

Imp

elle

r di

amet

er2

Oil

resi

stan

tIn

dust

ryC

oolin

g sh

roud

Enl

arge

d pa

ssag

e

Con

nect

ion

Mat

eria

l cas

ing

Pow

er

Vol

tage

Fre

que

ncy

Num

ber

of p

oles

Spe

ed

Ele

ctric

al c

onne

ctio

n

DO

L

DO

L

2900

rpm

2900

rpm

2P 2P

50H

z

50H

z

3 x

400

V

3 x

400V

2,2

kW

2,2

kW

1.44

08

1.44

08

G2

G2

IN O IN K VD

-100

S (S)

W

-2

22

22

10

10

V S V SK

V V R

D D

1. Only for sewage

2. Only for sewage

Page 6: EU sewage and waste water pumps - technical data dp-pumps

6

2 Specifications

2.1 DVV 3/4

Table 2: Materials

Table 3: Applications

Table 4: Dimensions

H[m]

Q [l/s]

Q [m3/h]0 2 4 8 10 12 14 16 180

2

4

6

8

10

12

13

0 1 2 3 4 5

DVV 35DVV 33

DVV 32 DVV 44

Casing PP-GF30, range 44 in PA

Housing 1.4301 / AISI304, IN version: 1.4571

Impeller Noryl

Shaft 1.4028 / AISI420, IN version: 1.4571

Seals SIMM

Elastomers NBR

Waste water drainage for household and industries

Construction sites and building services

Agriculture water supply and drainage

Water supply for irrigation systems

Utilities for de-watering

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

32 WS 0,18 1,9 1x230V G 5/4 10 335x215x325 4,8 6139300070

32 W(S) 0,18 1,9 1x230V G 5/4 10 335x215x325 5,6 6139300072

32 W(S) IN 0,18 1,9 1x230V G 5/4 10 335x215x325 5,6 6139300073

33 WS 0,36 4 1x230V G 5/4 10 335x215x363 6,6 6139300074

33 W(S) 0,36 4 1x230V G 5/4 10 335x215x363 7,2 6139300076

33 W(S) IN 0,36 4 1x230V G 5/4 10 335x215x363 7,2 6139300077

35 WS 0,5 4,9 1x230V G 5/4 10 335x215x363 6,5 6139300078

35 W(S) 0,5 4,9 1x230V G 5/4 10 335x215x363 7,4 6139300081

35 W(S) IN 0,5 4,9 1x230V G 5/4 10 335x215x363 7,4 6139300082

44 WS 0.43 4 1x230V G 6/4 35 390x232x420 7,5 6139300083

Page 7: EU sewage and waste water pumps - technical data dp-pumps

7

2.2 DVV 7

Table 5: Materials

Table 6: Applications

Table 7: Dimensions

Casing 1.4301 / AISI304

Housing 1.4301 / AISI304

Impeller PA

Shaft 1.4021 / AISI420

Seals SIC/SIC, SIMM

Elastomers NBR

De-watering effluents

Tunnel waste water drainage

Agriculture water supply and drainage

Water supply for irrigation systems

Light industrial, commercial and residential applications

H

W

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

76 0,55 1,7 3x400V G 6/4 10 300x280x440 13,3 61630070

76 S 0,55 1,7 3x400V G 6/4 10 300x280x440 15,1 61630079

76 W 0,55 4,1 1x230V G 6/4 10 300x280x440 12,2 61630085

76 WS 0,55 4,1 1x230V G 6/4 10 300x280x440 12,7 61630090

78 0,75 1,9 3x400V G 6/4 10 300x280x440 13,3 61630096

78 S 0,75 1,9 3x400V G 6/4 10 300x280x440 15,1 61630100

78 W 0,75 5,5 1x230V G 6/4 10 300x280x440 12,2 61630104

78 WS 0,75 5,5 1x230V G 6/4 10 300x280x440 12,7 61630108

711 1,1 2,5 3x400V G 6/4 10 300x280x440 13,3 61630711

711 W 1,1 6,55 1x230V G 6/4 10 300x280x440 14,5 61630712

711 WS 1,1 6,55 1x230V G 6/4 10 300x280x440 15 61630093

715 1,5 3,6 3x400V G 6/4 10 300x280x440 15,6 61630715

715 S 1,5 3,6 3x400V G 6/4 10 300x280x440 17,5 61630715

715 W 1,5 8,95 1x230V G 6/4 10 300x280x440 14,5 61630720

715 WS 1,5 8,95 1x230V G 6/4 10 300x280x440 15 61630725

722 2,2 4,8 3x400V G 6/4 10 300x280x440 15,7 61630722

722 S 2,2 4,8 3x400V G 6/4 10 300x280x440 17,6 61630735

Page 8: EU sewage and waste water pumps - technical data dp-pumps

8

2.3 DVV 7 K

Table 8: Materials

Table 9: Applications

Table 10: Dimensions

Casing 1.4301 / AISI304

Housing 1.4301 / AISI304

Impeller PA

Shaft 1.4021 / AISI420

Seals SIC/SIC, SIMM

Elastomers NBR

De-watering effluents

Tunnel waste water drainage

Agriculture water supply and drainage

Water supply for irrigation systems

Light industrial, commercial and residential applications

H

W

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

76 K 0,55 1,7 3x400V G 6/4 10 300x280x440 15,3 61630073

76 W K 0,55 4,1 1x230V G 6/4 10 300x280x440 14,2 61630088

76 WS K 0,55 4,1 1x230V G 6/4 10 300x280x440 14,7 61630093

78 K 0,75 1,9 3x400V G 6/4 10 300x280x440 15,3 61630098

78 S K 0,75 1,9 3x400V G 6/4 10 300x280x440 17,1 61630102

78 W K 0,75 5,5 1x230V G 6/4 10 300x280x440 14,2 61630106

78 WS K 0,75 5,5 1x230V G 6/4 10 300x280x440 14,7 61630110

711 S K 1,1 6,55 3x400V G 6/4 10 300x280x440 17,1 61630700

711 W K 1,1 6,55 1x230V G 6/4 10 300x280x440 16,5 61630696

711 WS K 1,1 6,55 1x230V G 6/4 10 300x280x440 17 61630389

715 K 1,5 3,6 3x400V G 6/4 10 300x280x440 17,6 61630713

715 S K 1,5 3,6 3x400V G 6/4 10 300x280x440 19,5 61630718

715 W K 1,5 8,95 1x230V G 6/4 10 300x280x440 16,5 61630723

715 WS K 1,5 8,95 1x230V G 6/4 10 300x280x440 17 61630728

722 K 2,2 4,8 3x400V G 6/4 10 300x280x440 17,7 61630732

722 S K 2,2 4,8 3x400V G 6/4 10 300x280x440 19,6 61630738

Page 9: EU sewage and waste water pumps - technical data dp-pumps

9

2.4 DVV 7 IN K

Table 11: Materials

Table 12: Applications

Table 13: Dimensions

Casing 1.4401 / AISI316

Housing 1.4401 / AISI316

Impeller PA

Shaft 1.4021 / AISI420

Seals SIC/SIC, SIMM

Elastomers NBR

Light acid and corrosive liquid applications

Tunnel waste water drainage

Industrial applications

H

W

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

76 IN K 0,55 1,7 3x400V G 6/4 10 300x280x440 15,3 61630071

76 S IN K 0,55 1,7 3x400V G 6/4 10 300x280x440 17,1 61630080

76 W IN K 0,55 4,1 1x230V G 6/4 10 300x280x440 14,2 61630086

76 WS IN K 0,55 4,1 1x230V G 6/4 10 300x280x440 14,7 61630091

78 IN K 0,75 1,9 3x400V G 6/4 10 300x280x440 17,3 61630097

78 S IN K 0,75 1,9 3x400V G 6/4 10 300x280x440 17,1 61630101

78 W IN K 0,75 5,5 1x230V G 6/4 10 300x280x440 14,2 61630105

78 WS IN K 0,75 5,5 1x230V G 6/4 10 300x280x440 14,7 61630109

711 IN K 1,1 2,5 3x400V G 6/4 10 300x280x440 14,3 61630707

711 S IN K 1,1 2,5 3x400V G 6/4 10 300x280x440 17,1 61630704

711 W IN K 1,1 6,55 1x230V G 6/4 10 300x280x440 16,5 61630698

711 WS IN K 1,1 6,55 1x230V G 6/4 10 300x280x440 17 61630092

715 IN K 1,5 3,6 3x400V G 6/4 10 300x280x440 17,6 61630721

715 S IN K 1,5 3,6 3x400V G 6/4 10 300x280x440 19,5 61630717

715 W IN K 1,5 8,95 1x230V G 6/4 10 300x280x440 16,5 61630721

715 WS IN K 1,5 8,95 1x230V G 6/4 10 300x280x440 17 61630726

722 S IN K 2,2 4,8 3x400V G 6/4 10 300x280x440 19,6 61630736

Page 10: EU sewage and waste water pumps - technical data dp-pumps

10

2.5 DVV 7 O K

Table 14: Materials

Table 15: Applications

Table 16: Dimensions

Casing 1.4301 / AISI304

Housing 1.4301 / AISI304

Impeller PA

Shaft 1.4021 / AISI420

Seals SIC/SIC, SIMM

Elastomers FKM

Oil content applications

Tunnel waste water drainage

Industrial applications

H

W

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

76 O K 0,55 1,7 3x400V G 6/4 10 300x280x440 15,3 61630074

76 S O K 0,55 1,7 3x400V G 6/4 10 300x280x440 17,1 61630083

76 W O K 0,55 4,1 1x230V G 6/4 10 300x280x440 14,2 61630089

76 WS O K 0,55 4,1 1x230V G 6/4 10 300x280x440 14,7 61630094

78 O K 0,75 1,9 3x400V G 6/4 10 300x280x440 17,3 61630099

78 S O K 0,75 1,9 3x400V G 6/4 10 300x280x440 17,1 61630103

78 W O K 0,75 5,5 1x230V G 6/4 10 300x280x440 14,2 61630107

78 WS O K 0,75 5,5 1x230V G 6/4 10 300x280x440 14,7 61630111

711 O K 1,1 2,5 3x400V G 6/4 10 300x280x440 14,3 61630705

711 S O K 1,1 2,5 3x400V G 6/4 10 300x280x440 17,1 61630699

711 W O K 1,1 6,55 1x230V G 6/4 10 300x280x440 16,5 61630695

711 WS O K 1,1 6,55 1x230V G 6/4 10 300x280x440 17 61630091

715 O K 1,5 3,6 3x400V G 6/4 10 300x280x440 17,6 61630714

715 S O K 1,5 3,6 3x400V G 6/4 10 300x280x440 19,5 61630719

715 W O K 1,5 8,95 1x230V G 6/4 10 300x280x440 16,5 61630724

715 WS O K 1,5 8,95 1x230V G 6/4 10 300x280x440 17 61630729

722 O K 2,2 4,8 3x400V G 6/4 10 300x280x440 17,7 61630733

722 S O K 2,2 4,8 3x400V G 6/4 10 300x280x440 19,6 61630736

Page 11: EU sewage and waste water pumps - technical data dp-pumps

11

2.6 DVV 7 VD

Table 17: Materials

Table 18: Applications

Table 19: Dimensions

Casing 1.4301 / AIS304

Housing 1.4301 / AISI304

Impeller PA

Shaft 1.4021 / AISI420

Seals SIC/SIC, SIMM

Elastomers NBR

Waste water drainage for household and industries

Construction sites and building services

Agriculture water supply and drainage

Water supply for irrigation systems

Utilities for de-watering

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

76 VD 0,55 1,7 3x400V G 6/4 35 300x280x500 14,4 61630078

76 S VD 0,55 1,7 3x400V G 6/4 35 300x280x500 16,1 61630084

76 W VD 0,55 4,1 1x230V G 6/4 35 300x280x500 13,2 61630076

76 WS VD 0,55 4,1 1x230V G 6/4 35 300x280x500 13,7 61630077

711 VD 1,1 2,5 3x400V G 6/4 35 300x280x500 14,4 61630701

711 S VD 1,1 2,5 3x400V G 6/4 35 300x280x500 16,1 61630703

711 W VD 1,1 6,55 1x230V G 6/4 35 300x280x500 15,5 61630712

711 WS VD 1,1 6,55 1x230V G 6/4 35 300x280x500 16 61630690

722 VD 2,2 4,8 3x400V G 6/4 35 300x280x500 16,9 61630734

722 S VD 2,2 4,8 3x400V G 6/4 35 300x280x500 18,7 61630740

Page 12: EU sewage and waste water pumps - technical data dp-pumps

12

2.7 DVV 10

Table 20: Materials

Table 21: Applications

Table 22: Dimensions

Casing JL 1040 / GG25, IN version 1.4408

Housing 1.4301 / AISI304, IN version 1.4408

Impeller PA

Shaft 1.4021 / AISI420, IN version 1.4571

Seals SIC/SIC, SIMM

Elastomers NBR, O version FKM

Waste water drainage for household and industries

Construction sites and building services

Agriculture water supply and drainage

Water supply for irrigation systems

Utilities for de-watering

W

H

L

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

1022 2,2 4,8 3x400V G 2 11 340x240x480 22,5 61631022

1022 IN 2,2 4,8 3x400V G 2 11 340x240x480 23,5 61631023

1022 O 2,2 4,8 3x400V G 2 11 340x240x480 23,5 61631024

1022 S 2,2 4,8 3x400V G 2 11 340x240x480 24,5 61631025

1022 S IN 2,2 4,8 3x400V G 2 11 340x240x480 25,5 61631026

1022 S O 2,2 4,8 3x400V G 2 11 340x240x480 25,5 61631027

Page 13: EU sewage and waste water pumps - technical data dp-pumps

13

2.8 DVV 27

Table 23: Materials

Table 24: Applications

Table 25: Dimensions

Casing JL 1040 / GG25, IN version special coated

Housing JL 1040 / GG25, IN version special coated

Impeller JL 1040 / GG25, optional hardened JL 1040

Shaft 1.4021

Seals TUC/TUC, TUC/TUC

Elastomers NBR

De-watering effluents

Tunnel waste water drainage

Agriculture water supply and drainage

Water supply for irrigation systems

Light industrial, commercial and residential applicationsL

H

W

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

2740 4 8,5 3x400V NW80 12 511x356x556 60,5 61632740

2740 S 4 8,5 3x400V NW80 12 511x356x556 61 61632742

2740 IN 4 8,5 3x400V NW80 12 511x356x556 60,5 61632741

2740 S IN 4 8,5 3x400V NW80 12 511x356x556 61 61632743

2775 7,5 15,4 3x400V NW100 12 511x356x556 94,5 61632775

2775 S 7,5 15,4 3x400V NW100 12 511x356x556 96 61632777

2775 IN 7,5 15,4 3x400V NW100 12 511x356x556 94,5 61632776

2775 S IN 7,5 15,4 3x400V NW100 12 511x356x556 96 61632778

Page 14: EU sewage and waste water pumps - technical data dp-pumps

14

2.9 DRV 6 100-110

Table 26: Materials

Table 27: Applications

Table 28: Dimensions

Casing JL 1030 / GG20

Housing JL 1030 / GG20

Impeller JL 1030 / GG20

Shaft 1.4021 / AISI420

Seals SIC/CE, SIMM

Elastomers NBR

Untreated residential sewage

Tunnel waste water drainage

Wastewater and sewage treatment plants

Municipal sewage networks

Sewage transport at industrial plants, airports and hotels

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

66-2 100 0,55 2,3 3x400V DN50 45 318x198x396 22 61650662

66-2 W 100 0,55 5 1x230V DN50 45 318x198x396 22 61650664

66-2 WS 100 0,55 5 1x220V DN50 45 318x198x396 22 61650666

68-2 110 0,75 2,8 3x400V DN50 45 318x198x396 22 61650682

68-2 W 110 0,75 6 1x230V DN50 45 318x198x396 22 61650683

68-2 WS 110 0,75 6 1x220V DN50 45 318x198x396 22 61650686

Page 15: EU sewage and waste water pumps - technical data dp-pumps

15

2.10 DRV 6 120-130

Table 29: Materials

Table 30: Applications

Table 31: Dimensions

Casing JL 1030 / GG20

Housing JL 1030 / GG20

Impeller JL 1030 / GG20

Shaft 1.4021 / AISI420

Seals SIC/CE, SIMM

Elastomers NBR

Untreated residential sewage

Tunnel waste water drainage

Wastewater and sewage treatment plants

Municipal sewage networks

Sewage transport at industrial plants, airports and hotels

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

611-2 120 1,1 3 3x400V DN50 45 318x198x396 22 61656112

611-2 W 120 1,1 8,2 1x230V DN50 45 318x198x396 22 61656114

611-2 W 130 1,1 8,2 1x230V DN50 45 318x198x396 22 61656115

611-2 WS 120 1,1 8,2 1x230V DN50 45 318x198x396 22 61656118

611-2 WS 130 1,1 8,2 1x230V DN50 45 328x198x398 22 61656119

615-2 130 1,5 3,5 3x400V DN50 45 318x198x396 22 61656152

Page 16: EU sewage and waste water pumps - technical data dp-pumps

16

2.11 DRV 8 110-120

Table 32: Materials

Table 33: Applications

Table 34: Dimensions

Casing JL 1030 / GG20

Housing JL 1030 / GG20

Impeller JL 1030 / GG20

Shaft 1.4021 / AISI420

Seals SIC/CE, SIMM

Elastomers NBR

Untreated residential sewage

Tunnel waste water drainage

Wastewater and sewage treatment plants

Municipal sewage networks

Sewage transport at industrial plants, airports and hotels

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

88-2 110 0,75 2,8 3x400V DN65 60 364x224x410 25 61650882

88-2 W 110 0,75 6 1x230V DN65 60 364x224x410 25 61650884

88-2 WS 110 0,75 6 1x220V DN65 60 364x224x410 25 61650886

811-2 120 1,1 3 3x400V DN65 60 364x224x410 25 61658112

811-2 W 120 1,1 8,2 1x230V DN65 60 364x224x410 25 61658105

811-2 WS 120 1,1 8,2 1x220V DN65 60 364x224x410 25 61658109

Page 17: EU sewage and waste water pumps - technical data dp-pumps

17

2.12 DRV 8 130

Table 35: Materials

Table 36: Applications

Table 37: Dimensions

Casing JL 1030 / GG20

Housing JL 1030 / GG20

Impeller JL 1030 / GG20

Shaft 1.4021 / AISI420

Seals SIC/CE, SIMM

Elastomers NBR

Untreated residential sewage

Tunnel waste water drainage

Wastewater and sewage treatment plants

Municipal sewage networks

Sewage transport at industrial plants, airports and hotels

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

811-2W 130 1,1 8,2 1x230V DN65 60 364x224x410 25 61658106

811-2 WS 130 1,1 8,2 1x230V DN65 60 364x224x410 25 61658110

815-2 130 1,5 3,5 3x400V DN65 60 364x224x410 25 61658152

Page 18: EU sewage and waste water pumps - technical data dp-pumps

18

2.13 DRV 9

Table 38: Materials

Table 39: Applications

Table 40: Dimensions

Casing JL 1040 / GG25

Housing JL 1040 / GG25

Impeller JL 1040 / GG25

Shaft 1.4021 / AISI420

Seals SIC/SIC, Ca/Ce

Elastomers NBR

Untreated residential sewage

Tunnel waste water drainage

Wastewater and sewage treatment plants

Municipal sewage networks

Sewage transport at industrial plants, airports and hotels

H

WL

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

913-2 90 1,3 3,56 3x400V NW50 40 364x322x470 41 61659135

913-2 107 1,3 3,56 3x400V NW50 40 364x322x470 41 61659132

919-2 120 1,9 4,5 3x400V NW50 40 364x322x470 42 61659192

923-2 130 2,3 5,1 3x400V NW50 40 364x322x470 42 61659232

Page 19: EU sewage and waste water pumps - technical data dp-pumps

19

2.14 DRV 11

Table 41: Materials

Table 42: Applications

Table 43: Dimensions

Casing JL 1040 / GG25

Housing JL 1040 / GG25

Impeller JL 1040 / GG25

Shaft 1.4021 / AISI420

Seals SIC/SIC, Ca/Ce

Elastomers NBR

Untreated residential sewage

Tunnel waste water drainage

Wastewater and sewage treatment plants

Municipal sewage networks

Sewage transport at industrial plants, airports and hotels

H

WL

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

1131-2 130 3,1 7 3x400V NW50 40 336x254x532 52 61651131

1131-2 140 3,1 7 3x400V NW50 40 336x254x532 52 61651134

1142-2 150 4,2 8,8 3x400V NW50 40 336x254x532 53 61651142

Page 20: EU sewage and waste water pumps - technical data dp-pumps

20

2.15 DRV 12

Table 44: Materials

Table 45: Applications

Table 46: Dimensions

Casing JL 1040 / GG25

Housing JL 1040 / GG25

Impeller JL 1040 / GG25

Shaft 1.4021 / AISI420

Seals SIC/SIC, Ca/Ce

Elastomers NBR

Untreated residential sewage

Tunnel waste water drainage

Wastewater and sewage treatment plants

Municipal sewage networks

Sewage transport at industrial plants, airports and hotels

H

WL

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

128-4 112 0,8 2,7 3x400V NW65 65 353x265x518 49 61651284

128-4 125 0,8 2,7 3x400V NW65 65 353x265x518 49 61651285

128-4 135 0,8 2,7 3x400V NW65 65 353x265x518 49 61651286

128-4 145 0,8 2,7 3x400V NW65 65 353x265x518 49 61651289

128-4 155 0,8 2,7 3x400V NW65 65 353x265x518 49 61651292

1213-4 165 1,3 3,54 3x400V NW65 65 353x265x518 50 61651213

1213-4 175 1,3 3,54 3x400V NW65 65 353x265x518 50 61651216

1218-4 185 1,8 4,25 3x400V NW65 65 353x265x518 51 61651218

1218-4 195 1,8 4,25 3x400V NW65 65 353x265x518 51 61651221

Page 21: EU sewage and waste water pumps - technical data dp-pumps

21

2.16 DRV 13

Table 47: Materials

Table 48: Applications

Table 49: Dimensions

Casing JL 1040 / GG25

Housing JL 1040 / GG25

Impeller JL 1040 / GG25

Shaft 1.4021 / AISI420

Seals SIC/SIC, Ca/Ce

Elastomers NBR

Untreated residential sewage

Tunnel waste water drainage

Wastewater and sewage treatment plants

Municipal sewage networks

Sewage transport at industrial plants, airports and hotels

H

WL

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

1331-2 120 3,1 7 3x400V NW65 65 367x251x578 58 61651325

1331-2 128 3,1 7 3x400V NW65 65 367x251x578 58 61651328

1331-2 136 3,1 7 3x400V NW65 65 367x251x578 59 61651331

1342-2 146 4,2 8,8 3x400V NW65 65 367x251x578 59 61651343

1342-2 152 4,2 888 3x400V NW65 65 367x251x578 60 61651342

Page 22: EU sewage and waste water pumps - technical data dp-pumps

22

2.17 DRV 24

Table 50: Materials

Table 51: Applications

Table 52: Dimensions

Casing JL 1040 / GG25

Housing JL 1040 / GG25

Impeller JL 1040 / GG25

Shaft 1.4021 / AISI420

Seals SIC/SIC, Ca/Ce

Elastomers NBR

Untreated residential sewage

Tunnel waste water drainage

Wastewater and sewage treatment plants

Municipal sewage networks

Sewage transport at industrial plants, airports and hotels

H

WL

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

2419-4 120 1,9 5,87 3x400V NW80 76 392x322x582 63 61652419

2419-4 135 1,9 5,87 3x400V NW80 76 392x322x582 63 61652420

2419-4 150 1,9 5,87 3x400V NW80 76 392x322x582 63 61652423

2426-4 165 2,6 6,5 3x400V NW80 76 392x322x582 64 61652426

2437-4 180 3,7 8,4 3x400V NW80 76 392x322x582 65 61652437

2437-4 195 3,7 8,4 3x400V NW80 76 392x322x582 65 61652440

Page 23: EU sewage and waste water pumps - technical data dp-pumps

23

2.18 DRV 27

Table 53: Materials

Table 54: Applications

Table 55: Dimensions

Casing JL 1040 / GG25

Housing JL 1040 / GG25

Impeller JL 1040 / GG25

Shaft 1.4021 / AISI420

Seals SIC/SIC, Ca/Ce

Elastomers NBR

Untreated residential sewage

Tunnel waste water drainage

Wastewater and sewage treatment plants

Municipal sewage networks

Sewage transport at industrial plants, airports and hotels

H

WL

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

2719-4 120 1,9 5,87 3x400V NW100 100 392x322x582 64 61652719

2719-4 135 1,9 5,87 3x400V NW100 100 392x322x582 64 61652720

2726-4 150 2,6 6,5 3x400V NW100 100 392x322x582 64 61652726

2737-4 165 3,7 8,4 3x400V NW100 100 392x322x582 65 61652737

2737-4 180 3,7 8,4 3x400V NW100 100 392x322x582 66 61652740

2737-4 195 3,7 8,4 3x400V NW100 100 392x322x582 67 61652743

Page 24: EU sewage and waste water pumps - technical data dp-pumps

24

2.19 DRSK 21

Table 56: Materials

Table 57: Applications

Table 58: Dimensions

Casing JL 1040 / GG25

Housing JL 1040 / GG25

Impeller JL 1040 / GG25

Shaft 1.4021 / AISI420

Seals SIC/SIC, Ca/Ce

Elastomers NBR

Untreated residential sewage

Tunnel waste water drainage

Wastewater and sewage treatment plants

Municipal sewage networks

Sewage transport at industrial plants, airports and hotels

H

WL

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

2119-4 154 1,9 5,87 3x400V NW80 65 392x322x602 74 61666213

2119-4 168 1,9 5,87 3x400V NW80 65 392x322x602 74 61666214

2119-4 180 1,9 5,87 3x400V NW80 65 392x322x602 74 61666215

2119-4 190 1,9 5,87 3x400V NW80 65 392x322x602 75 61666216

Page 25: EU sewage and waste water pumps - technical data dp-pumps

25

2.20 DRSK 31

Table 59: Materials

Table 60: Applications

Table 61: Dimensions

Casing JL 1040 / GG25

Housing JL 1040 / GG25

Impeller JL 1040 / GG25

Shaft 1.4021 / AISI420

Seals SIC/SIC, Ca/Ce

Elastomers NBR

Untreated residential sewage

Tunnel waste water drainage

Wastewater and sewage treatment plants

Municipal sewage networks

Sewage transport at industrial plants, airports and hotels

H

WL

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

3126-4 195 2,6 6,5 3x400V NW100 76 383x318x628 79 61666217

3137-4 209 3,7 8,4 3x400V NW100 76 383x318x628 79 61666218

3137-4 220 3,7 8,4 3x400V NW100 76 383x318x628 80 61666219

Page 26: EU sewage and waste water pumps - technical data dp-pumps

26

2.21 DRS 3, 1x230V

Table 62: Materials

Table 63: Applications

Table 64: Dimensions

Casing JL 1030 / GG20

Housing JL 1030 / GG20

Impeller JL 1030 / GG20

Shaft 1.4021 / AISI420

Seals SIC/SIC, Simm

Elastomers NBR

Residential waste water collection systems

Municipal sewage plants and network

Industrial and commercial wastewater applications

H

W

L

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

311-2 W 145 1,1 8,2 1x230V DN50 7 318x198x396 26 61663112

311-2 WS 145 1,1 8,2 1x230V DN50 7 318x198x396 26 61663114

Page 27: EU sewage and waste water pumps - technical data dp-pumps

27

2.22 DRS 3, 3x400V

Table 65: Materials

Table 66: Applications

Table 67: Dimensions

Casing JL 1030 / GG20

Housing JL 1030 / GG20

Impeller JL 1030 / GG20

Shaft 1.4021 / AISI420

Seals SIC/SIC, Simm

Elastomers NBR

Residential waste water collection systems

Municipal sewage plants and network

Industrial and commercial wastewater applications

H

W

L

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

315-2 145 1,5 3,5 3x400V DN50 7 318x198x396 24 61663115

Page 28: EU sewage and waste water pumps - technical data dp-pumps

28

2.23 DRS 4

Table 68: Materials

Table 69: Applications

Table 70: Dimensions

Casing JL 1040 / GG25

Housing JL 1040 / GG25

Impeller JL 1040 / GG25

Shaft 1.4021 / AISI420

Seals SIC/SIC, Ca/Ce

Elastomers NBR

Residential waste water collection systems

Municipal sewage plants and network

Industrial and commercial wastewater applications

LW

H

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

413-2 120 1,3 3,56 3x400V NW50 6 322x250x470 39 61664132

413-2 140 1,3 3,56 3x400V NW50 6 322x250x470 39 61664133

419-2 160 1,9 4,5 3x400V NW50 6 322x250x470 39 61664192

Page 29: EU sewage and waste water pumps - technical data dp-pumps

29

2.24 DRS 6

Table 71: Materials

Table 72: Applications

Table 73: Dimensions

Casing JL 1040 / GG25

Housing JL 1040 / GG25

Impeller JL 1040 / GG25

Shaft 1.4021 / AISI420

Seals SIC/SIC, Ca/Ce

Elastomers NBR

Residential waste water collection systems

Municipal sewage plants and network

Industrial and commercial wastewater applications

LW

H

Model Power [kW]

Current [A]

Voltage Connection Free passage[mm]

Dimensions (LxWxH) [mm]

Weight [kg]

Part number

631-2 175 3,1 7 3x400V NW50 6 336x254x532 54 61666312

642-2 190 4,2 8,8 3x400V NW50 6 336x254x532 54 61666313

Page 30: EU sewage and waste water pumps - technical data dp-pumps

30

Page 31: EU sewage and waste water pumps - technical data dp-pumps

31

Page 32: EU sewage and waste water pumps - technical data dp-pumps

dp pumps

P.O. Box 282400 AA Alphen aan den Rijn

t +31 172 48 83 88f +31 172 46 89 30

[email protected]

08/2015

97004474-C

Subject to modifications. Digital alteration or publishing of the content of this document without prior notice is strictly prohibited. Permission for use, copying and distribution of this document are published by DP-Industries is granted on the condition that no part of the document is used for information or commercial purposes outside of the DP-industries organisation or one of its recognised dealerships.