Ethernet Communication Module B420 en Installation and Operation Guide

Transcript of Ethernet Communication Module - Bosch...

Page 1: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

Ethernet Communication ModuleB420

en Installation and Operation Guide

Page 2: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can
Page 3: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

Ethernet Communication Module Table of Contents | en 3

Bosch Security Systems, Inc. Installation and Operation Guide F01U215236 | 02 | 2011.11

Table of Contents

1 Introduction 4

1.1 Reading Bosch Security Systems, Inc. Product Date Codes 4

1.2 Trademarks 4

1.3 Overview B420 4

1.4 Technical Specifications 7

1.5 Certifications 7

2 Installation 8

3 Configuration 12

3.1 Configuring for SDI2 Control Panels (GV4 Only) 12

3.1.1 Address-only Configuration for SDI2 Control Panels 12

3.1.2 Web-based Configuration for SDI2 Control Panels 12

3.2 Configuring for SDI or Option Bus Control Panels 12

3.2.1 Address-only Configuration for SDI or Option Control Panels 12

3.2.2 Web-based Configuration for SDI2 or Option Bus Control Panels 13

3.3 Determining a Module’s Hostname or IP Address 13

3.3.1 Determining a Module’s Hostname 13

3.3.2 Using a GV4 Series Keypad to Discover the IP Address of a Module 13

3.3.3 Using DHCP to Look Up the IP Address of a Network-connected Module 13

3.3.4 Using Auto IP with a Directly Connected Module 14

3.4 Accessing the B420 Configuration Pages 14

3.5 Device Information (Home) Page 15

3.6 Changing and Saving Settings Using the Web 16

3.7 Basic Network Settings Page 16

3.8 Advanced Network Settings Page 19

3.9 Panel Address Setting Page 20

3.10 Encryption Setting Page 21

3.11 Maintenance Page 22

3.12 Factory Default Page 23

3.13 Firmware Upgrade Page 25

3.14 Exiting the Configuration Web Page 26

4 Maintenance and Troubleshooting LEDs 27

Page 4: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

4 en | Introduction Ethernet Communication Module

F01U215236 | 02 | 2011.11 Installation and Operation Guide Bosch Security Systems, Inc.

1 Introduction

1.1 Reading Bosch Security Systems, Inc. Product Date CodesFor Product Date Code information, refer to the Bosch Security Systems, Inc. web site at

http://www.boschsecurity.com/datecodes.

1.2 TrademarksTrademark names are used throughout this document. In most cases, these designations are

claimed as trademarks or registered trademarks in one or more countries by their respective

owners. Rather than placing a trademark symbol in every occurrence of a trademark name,

Bosch Security Systems, Inc. (hereinafter referred to as Bosch) uses the names only in an

editorial fashion and to the benefit of the trademark owner with no intention of infringing the

trademark.

1.3 Overview B420

Use the Conettix B420 Network Interface Module for bi-directional communication over an

Ethernet network. Refer to Figure 1.1, Page 5 for general system connections.

WARNING!

Failure to follow these instructions can result in a failure to initiate alarm conditions. Bosch

Security Systems, Inc. is not responsible for improperly installed, tested, or maintained

devices. Follow these instructions to avoid personal injury and damage to the equipment.

NOTICE!

Inform the operator and the local authority having jurisdiction (AHJ) before installing the B420

in an existing system.

Disconnect all power to the control panel before installing the B420.

Before installing the B420, refer to Section 1.4 Technical Specifications, page 7

Page 5: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

Ethernet Communication Module Introduction | en 5

Bosch Security Systems, Inc. Installation and Operation Guide F01U215236 | 02 | 2011.11

Figure 1.1 System Connections Overview

Refer to Figure 1.2, Page 6 for an overview of the B420.

Callout Description

1 Compatible Bosch control panel

2 Data bus connection between the control panel and the B420

3 B420 Ethernet Communication Module

4 Ethernet connection between B420 and Ethernet network

5 Ethernet network, Local Area Network (LAN), Metropolitan AreaNetwork (MAN),

Wide Area Network (WAN), or Internet

6 Ethernet network connection to the D6100i Communications Receiver

7 Conettix D6100i Communications Receiver/Gateway

8 Ethernet network connection to the D6680/ITS-D6682 (ITS-D6682 shown)

Ethernet Network Adapter

9 Conettix D6680/ITS-D6682 (ITSD6682 shown) Ethernet Network Adapter

10 Connection from ITS-D6682 to the COM4 Port on the D6600

CommunicationsReceiver/Gateway COM4 Port

11 Conettix D6600 Communications Receiver/Gateway

12 Ethernet network connection between the host computer Ethernet network

interface card (NIC) and the Ethernet network

13 Host PC running RPS, Automation, or the D6200 Programming Administrative

Software

1

4

5

6

3

2

7

8

9

10

12

13

11

Page 6: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

6 en | Introduction Ethernet Communication Module

F01U215236 | 02 | 2011.11 Installation and Operation Guide Bosch Security Systems, Inc.

Figure 1.2 B420 Network Interface Module

Callout Description

1 Ethernet RJ-45 port

2 Address switch

3 Data BUS communication LEDs (TX and RX)

4 Heartbeat LED

5 Terminal strip (to control panel)

6 Interconnect wiring connectors P2 and P3 (to control panel or other compatible

modules)

7 Ethernet Status LEDs (on connection side of the RJ45 jack)

Page 7: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

Ethernet Communication Module Introduction | en 7

Bosch Security Systems, Inc. Installation and Operation Guide F01U215236 | 02 | 2011.11

1.4 Technical Specifications

1.5 Certifications

Dimensions (HxWxD) (63.3 mm x 101 mm x 16 mm) (2.49 in x 3.9 in x 0.629 in)

Current (Maximum) – 10BaseT Ethernet: 90 mA max

– 100BaseT Ethernet: 100 mA max

Voltage (Operating) 12 VDC Nominal

Connectors – Control panel: Option or data bus terminals

– LAN/WAN: RJ-45 modular port (Ethernet)

Ethernet Cable – Category 5 or better unshielded twisted pair

– 100 m (328 ft) max length

Interface IEEE 802.3

Data Bus Wire Size 2 mm to 0.65 mm (18 AWG to 22 AWG)

Data Bus Wire Length 150 m (500 ft) - 0.65 mm (22 AWG)

300 m (1000 ft) - 2 mm (18 AWG)

Web Browser Microsoft Internet Explorer 6 or higher; Mozilla Firefox 3 or

higher

Compatible Control Panels – FPD-7024 Version 2.10 or higher

– G Series Version 7.0 or higher

– GV2 Series Version 7.06 or higher

– GV3 Series Version 8.02 or higher

– GV4 Series Version 1.00 or higher

Region Certification Applicable Control Panels

US UL 365 - Police Station Connected Burglar

Alarm Units and Systems

GV4 Series, GV3 Series

UL 864 - Control Units and Accessories for

Fire Alarm Systems (including NFPA 72)

GV4 Series, GV3 Series, FPD-7024

UL 1610 - Central-Station Burglar-Alarm

Units

GV4 Series, GV3 Series

FCC Part 15 Class A GV4 Series, GV3 Series, FPD-7024

CSFM - California Office of The State Fire

Marshal

GV4 Series, GV3 Series, FPD-7024

NIST FIPS-197 AES Certification (IP

Communications)

GV4 Series, GV3 Series, FPD-7024

Page 8: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

8 en | Installation Ethernet Communication Module

F01U215236 | 02 | 2011.11 Installation and Operation Guide Bosch Security Systems, Inc.

2 Installation1. Set the rotary switch on the B420 to the appropriate address to ensure proper

communication between device and control panel. Refer to Table 2.1. Refer to Figure 1.2,

Page 6 for the location of the rotary switch.

Table 2.1 B420 Rotary Switch Settings

2. Mount the B420 inside the enclosure using any of the standard three-point mounting

patterns. Secure the B420 to the enclosure using the supplied screws. Refer to

Figure 2.1, Page 9.

Control Panels Switch

Position

B420 Address Bus Type Function

Web-based configuration

setting

0 Configurable Any Web-based

Configuration

GV4 Series 1 1 SDI2 Automation or RPS,

Reporting

GV4 Series 2 2 SDI2 Automation or RPS,

Reporting

GV4 Series, GV3 Series, GV2

Series, G Series, D9412/

D7412/D7212, D9112

3 80 SDI Automation

GV4 Series, GV3 Series, GV2

Series, G Series, D9412/

D7412/D7212, D9112

4 88 SDI RPS, Reporting

GV4 Series, GV3 Series 5 92 SDI RPS, Reporting

NOTICE!

Web browser configuration of the module address can only be done when the switch is in the

’0’ position.

NOTICE!

The enclosure that contains the B420 can be no further than 20 ft from the control panel

enclosure and must be located in same room. The wiring between enclosures must be

contained within metal conduit.

Page 9: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

Ethernet Communication Module Installation | en 9

Bosch Security Systems, Inc. Installation and Operation Guide F01U215236 | 02 | 2011.11

Figure 2.1 Mounting the B420

3. Run the wiring connections from the B420 to the data bus terminals on the compatible

control panel. Refer to Figure 2.2, Page 10.

4. Connect the Ethernet cable to the Ethernet port on the B420. Refer to Figure 2.2,

Page 10.

Callout Description

1 B420 with mounting bracket installed

2 Enclosure

3 Mounting Screws (3)

Page 10: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

10 en | Installation Ethernet Communication Module

F01U215236 | 02 | 2011.11 Installation and Operation Guide Bosch Security Systems, Inc.

Figure 2.2 Wiring to an SDI2 Terminal Strip or Interconnect Wiring Connector

Figure 2.3 Wiring to an Option Bus Terminal Strip

Callout Description

1 Compatible control panel (GV4 Series Control Panel shown)

2 B420

3 To Ethernet network

4 Terminal strip wiring

5 Interconnect cable wiring (P/N: F01U079745) (included)

Callout Description

1 Compatible control panel (FPD7024 Control Panel shown)

2 B420

3 To Ethernet network

4 Terminal strip wiring

Page 11: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

Ethernet Communication Module Installation | en 11

Bosch Security Systems, Inc. Installation and Operation Guide F01U215236 | 02 | 2011.11

Figure 2.4 Wiring to an SDI Terminal Strip

For complete wiring instructions, refer to the control panel documentation.

Callout Description

1 Compatible control panel (GV3 Series Control Panel shown)

2 B420

3 To Ethernet network

4 Terminal strip wiring

5 Interconnect cable wiring (P/N: F01U079745) (included)

Page 12: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

12 en | Configuration Ethernet Communication Module

F01U215236 | 02 | 2011.11 Installation and Operation Guide Bosch Security Systems, Inc.

3 Configuration

3.1 Configuring for SDI2 Control Panels (GV4 Only)

3.1.1 Address-only Configuration for SDI2 Control PanelsYou can quickly configure this device by setting the device’s address switch to 1 or 2, and

then connecting it to the control panel.

You can use address-only configuration when an SDI2 control panel is programmed with

proper network settings, and Panel Programming is enabled in the B420 Panel Programming

configuration web pages (refer to Section 3.11 Maintenance Page, page 22). Panel

Programming is enabled by default to allow for easy field installation and replacement.

Address-only Configuration ConditionsSDI2-compatible control panels can automatically configure a new module.

1. Ensure the B420 is new, or defaulted to the factory settings.

2. Set the module’s address switch to the correct SDI2 address for the control panel.

3. Program the control panel with the desired settings.

4. Connect the module to the control panel bus and apply power.

The control panel stores the B420 settings and automatically programs a defaulted B420

when connected. To override automatic module programming, use the web configuration to

set the Panel Programming Enable parameter to NO before installing.

3.1.2 Web-based Configuration for SDI2 Control PanelsOnce Panel Programming is disabled, you can use web-based configuration - the B420

Configuration Pages - to configure B420 modules. To use this feature, you must know the

module’s hostname or IP address. Refer to Section 3.3 Determining a Module’s Hostname or IP

Address, page 13, and then follow the instructions in Section 3.4 Accessing the B420

Configuration Pages, page 14 through Section 3.14 Exiting the Configuration Web Page, page 26.

3.2 Configuring for SDI or Option Bus Control Panels

3.2.1 Address-only Configuration for SDI or Option Control PanelsYou can quickly and easily configure this device by simply setting the device’s address switch

to the address for a compatible control panel, and then connecting it to that control panel’s

bus.

Address-only Configuration Conditions

A SDI or Option Bus control panel supports address-only configuration when:

NOTICE!

Modules permit Panel Programming by default. For field replacements, when you connect the

replacement module, GV4 Series control panels with non-factory settings override the B420

settings. To keep custom B420 settings when you connect a module to a GV4 control panel,

you must disable Panel Programming.

NOTICE!

You cannot access the configuration web pages for a B420 if the module is connected to a

GV4 Series control panel and the Web Access Enable option is set to No. No is the default

value for GV4 Series control panels. To re-enable Web Access to the B420, use RPS or the

control panel keypad while the device is connected.

Page 13: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

Ethernet Communication Module Configuration | en 13

Bosch Security Systems, Inc. Installation and Operation Guide F01U215236 | 02 | 2011.11

– The following alarm communication and supervision conditions are met:

– Control panel is programmed for network communication to your Central Station

– DHCP is available on your network

– AES Encryption is not required

– Defaulted B420 access settings are permitted by the network administrator

– The following remote control panel programming conditions are met:

– UPnP is enabled on the network router for automatic port mapping

– UDP traffic on port 7700 is enabled

3.2.2 Web-based Configuration for SDI2 or Option Bus Control PanelsYou can use web-based configuration - B420 configuration Pages - to configure B420 modules.

To use this feature, you must know the module’s hostname or IP address. Refer to

Section 3.3 Determining a Module’s Hostname or IP Address, page 13, and then follow the

instructions in Section 3.4 Accessing the B420 Configuration Pages, page 14 through

Section 3.14 Exiting the Configuration Web Page, page 26.

3.3 Determining a Module’s Hostname or IP AddressTo log into the B420 Configuration Pages, you must obtain the IP address assigned to the

B420 or use the module’s hostname. To obtain the IP address, use the appropriate method

described below based on the B420 installation.

3.3.1 Determining a Module’s HostnameThe factory default configuration of the B420 allows the DHCP server to assign an IP address

and a hostname. A default hostname based on the MAC address is registered with the DNS

server if the module has not been programmed for a specific hostname (refer to

Section Module Hostname, page 23). You can use the hostname for modules configured for

dynamic DHCP or static IP addresses. Hostnames cannot be used when connecting directly

using Auto IP (refer to Section 3.3.4 Using Auto IP with a Directly Connected Module, page 14).

The default hostname for the B420 is the letter B followed by the last six alpha-numeric digits

of its MAC address (for example, B3f603f).

3.3.2 Using a GV4 Series Keypad to Discover the IP Address of a ModuleIf the B420 is connected to a GV4 Series Control Panel, you can use a connected keypad to

look up the IP address.

Finding the B420’s IP address using a keypad (D1260 instructions):

1. On the keypad, press [99] [ENTER].

2. Press the Next softkey repeatedly to navigate to the Tools Menu option.

3. Press the Tools Menu softkey. The keypad instructs you to enter the installer passcode.

4. Enter the passcode and press [ENTER]. The Tools Menu opens.

5. Press the Next softkey repeatedly to navigate to the IP Diagnostics option.

6. Press the corresponding soft button to enter the IP Diagnostics option.

7. At the B420 Module 1-2 option, enter the number for the B420 module for which you

want to review the settings, and press [ENTER].

8. Press [ENTER] at the Settings option. The keypad shows the Hostname.

9. Press the Next soft button. The keypad shows the MAC ID.

10. Press the Next soft button. The keypad shows the IP address assigned to the module.

11. Press the Exit soft button when finished reviewing the settings.

3.3.3 Using DHCP to Look Up the IP Address of a Network-connected Module If the B420 is connected to a network, a DHCP (Dynamic Host Configuration Protocol) server

assigns the IP address to the B420.

Page 14: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

14 en | Configuration Ethernet Communication Module

F01U215236 | 02 | 2011.11 Installation and Operation Guide Bosch Security Systems, Inc.

Looking up the B420’s IP address on the DHCP server:

1. Log into the DHCP server.

2. Locate the IP address table on the DHCP server.

3. Use the MAC address assigned to the B420 (indicated on the label on the Ethernet RJ-45

port), to find the IP address assigned to the B420.

3.3.4 Using Auto IP with a Directly Connected ModuleIf the B420 is connected directly to a computer (laptop or PC) and is not connected to a

network (no network hub, router, or switch is connected), you can use the B420’s Auto IP

feature to assign a static IP address to the B420.

If the B420’s IP address is not recorded in the host computer’s ARP table and you do not

know the address, set the rotary switch to the 0 position, cycle the power to the module, and

then follow the steps below.

Using the AutoIP feature:

1. Direct connect the B420 to the Ethernet port on a computer and wait 60 sec.

2. Open an internet browser (Microsoft Internet Explorer 5 or higher, or Mozilla Firefox 3 or

higher) and type in the default Auto IP address for the B420: 169.254.1.1.

3. Enter the default password: "B42V2" and click Login.

The Device Information page opens. Refer to Section 3.5 Device Information (Home) Page,

page 15 for more information.

If Auto IP does not work on the host computer, a new registry key might be required to enable

Auto IP. Be sure to obtain permission from your company IT department before changing the

registry.

To enable Auto IP on the host computer with a new registry key:

1. Open Notepad and create a new file called AutoIP.reg.

2. In Noteplad, include the following text:

Windows Registry Editor Version 5.00

[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\Tcpip\Parameters]

"IPAutoconfigurationEnabled"=dword:00000001

3. Save the file to a location on the host computer that you can easily find.

4. Navigate to the saved file and double-click on it to add it to the host computer’s registry.

5. Restart the host computer.

3.4 Accessing the B420 Configuration PagesYou can use the module’s IP address or its hostname (unless directly connected using

AutoIP), to access the B420 Configuration Pages. Refer to Section 3.3 Determining a Module’s

Hostname or IP Address, page 13 if you do not know the IP address or the hostname.

1. Open an internet browser (Microsoft Internet Explorer 6 or higher, or Mozilla Firefox 3 or

higher) and type in the B420’s IP address as the URL or type in the module hostname.

2. In the address bar, enter the B420’s IP address or hostname as the URL (for example,

http://10.25.110.111 or http://B3f603f).

NOTICE!

Before trying the Auto IP option, ensure that the web browser is not configured to use a proxy

server. Refer to the browser’s online help for instructions on disabling proxy service.

Page 15: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

Ethernet Communication Module Configuration | en 15

Bosch Security Systems, Inc. Installation and Operation Guide F01U215236 | 02 | 2011.11

3. The B420’s login page opens. Refer to Figure 3.1.

Figure 3.1 B420 Login Page

4. Enter the default password: "B42V2" and click Login.

The Device Information page opens. Refer to Section 3.5 Device Information (Home) Page,

page 15 for more information.

3.5 Device Information (Home) PageThe Device Information page shows basic information for the B420 in its main pane, and

provides links to the configuration web pages along the left-hand side.

By

NOTICE!

The factory default configuration of the B420 allows the DHCP and DNS servers to assign an

IP address and a DNS hostname. A default hostname based on the MAC address is used if the

module has not been programmed for a specific hostname (refer to Section Module Hostname,

page 23). You can use this method for modules configured for dynamic DHCP or static IP

addresses, but not when directly connected using Auto IP. The default hostname for the B420

is the letter B followed by the last six digits of its MAC address.

NOTICE! It is recommended to change your password after completing Step 4 for security of

the module configuration. The Web Login Password can be changed from the Maintenance

page as described in Section 3.11.

Page 16: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

16 en | Configuration Ethernet Communication Module

F01U215236 | 02 | 2011.11 Installation and Operation Guide Bosch Security Systems, Inc.

Figure 3.2 B420 Device Information Page

Refer to the following sections for descriptions of the configuration web pages.

3.6 Changing and Saving Settings Using the WebThe settings for the B420 are grouped by topic in the left column of the web interface in a

B420 menu structure. Refer to Figure 3.2, Page 16.

Some settings (menu options) might be unavailable if:

– The setting conflicts with another configured setting (for example, the Static IP setting is

unavailable when DHCP is enabled)

– The setting conflicts with a the address setting (for example: the Panel Address setting

is read-only if the address switch is set to anything but 0)

– The setting is unavailable in the current product release

Saving Settings Using the WebTo preserve edited values, click the OK button on each page before navigating to a different

setting page (menu).

To save all edited values and apply them to the module, click the Save and Execute link.

3.7 Basic Network Settings PageFigure 3.3 shows the Basic Network Setting web page.

Page 17: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

Ethernet Communication Module Configuration | en 17

Bosch Security Systems, Inc. Installation and Operation Guide F01U215236 | 02 | 2011.11

Figure 3.3 Basic Network Setting Web Page

DHCP/AutoIP Enable

DHCP is an auto configuration protocol that allows a computer to be automatically

configured, which eliminates the need for interaction by a network administrator. DHCP also

provides a central database that tracks computers that connect to the network, which

prevents two computers from accidentally being configured with the same IP address.

AutoIP enables dynamic IP addresses to be assigned to a device when the device is started

up. Whereas DHCP requires a DHCP server, AutoIP does not require a server when selecting

an IP address. A host configured with AutoIP receives an IP address of 169.254.xxx.xxx.

Open an internet browser (Microsoft Internet Explorer 6 or higher, or Mozilla Firefox 2 or

higher) and type in the B420’s hostname or IP address as the URL (for example, http://

10.25.110.111).

Static IP Address

An Internet Protocol (IP) address is a numerical label that is assigned to devices participating

in a computer network that uses the Internet Protocol for communication between its nodes.

When DHCP/AutoIP Enable is set to Yes, this parameter cannot be changed.

Subnet Mask

NOTICE!

The IPV6 Mode option is not supported in this version.

Default: YesSelection: Yes or NoYes DHCP/AutoIP is enabledNo DHCP/AutoIP is disabled

Default: 0.0.0.0Selection: 0.0.0.0 to 255.255.255.255

Default: 255.255.255.0Selection: 0.0.0.0 to 255.255.255.255

Page 18: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

18 en | Configuration Ethernet Communication Module

F01U215236 | 02 | 2011.11 Installation and Operation Guide Bosch Security Systems, Inc.

Subnetting is used to break the network into smaller, more efficient subnets to prevent

excessive rates of Ethernet packet collision in a large network. A significant feature of

subnetting is the subnet mask. Applying a subnet mask to an IP address allows you to identify

the network and node parts of the address. When DHCP/AutoIP Enable is set to Yes, this

parameter cannot be changed.

Default Gateway

A gateway is a node (typically a router) on a TCP/IP network that serves as an access point to

another network. A host uses a default gateway when an IP packet's destination address

belongs to someplace outside the local subnet. The default gateway address is usually an

interface belonging to the LAN's border router. In DHCP mode, the default gateway is usually

resolved automatically. When DHCP/AutoIP Enable is set to Yes, this parameter cannot be

changed.

DNS Server IP Address

A Domain Name Server (DNS) converts internet domain names or hostnames to their

corresponding IP addresses. This setting is used to configure a DNS server address in Static

IP mode. In DHCP mode, the default value of 0.0.0.0 indicates the DHCP server’s default DNS

will be used. To use a custom DNS server in DHCP mode, change the parameter to the

specified DNS server’s IP address.

Local Port

This option sets the local port number that the module listens for in-coming network traffic.

Default: 0.0.0.0Selection: 0.0.0.0 to 255.255.255.255

Default: 0.0.0.0Selection: 0.0.0.0 to 255.255.255.255

Default: 7700Selection: 0 to 65535

Page 19: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

Ethernet Communication Module Configuration | en 19

Bosch Security Systems, Inc. Installation and Operation Guide F01U215236 | 02 | 2011.11

3.8 Advanced Network Settings PageFigure 3.4 shows the Advanced Network Setting web page.

Figure 3.4 Advanced Network Setting Web Page

Legacy Panel Mode

This option allows the B420 to support legacy control panels that communicate using

Datagram Mode 0. When Legacy Panel Mode is enabled, the B420 uses the Local Port

parameter as both the source port and destination port for communication.

The control panels that use Legacy Panel Mode are:

– GV2 Series v7.05 and lower

– G Series v6.99 and lower

– DS7400XiV4

Port 77EE Configuration Enable

Port number 77EE (hexadecimal code) is reserved for configuration of the B420 by the remote

application software.

HTTP Port Number

Use this option to configure the port number for the B420 web server.

Default: 0 (Disable)Selection: 0 or 10 Legacy Panel Mode is disabled1 Legacy Panel Mode is enabled

Default: NoSelection: Yes or NoYes The network configuration port is enabled. The remote application

software can configure the B420 through this port.No The network configuration port is disabled. The remote application

software cannot configure the B420 through this port.

Default: 80Selection: 1 to 65535

Page 20: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

20 en | Configuration Ethernet Communication Module

F01U215236 | 02 | 2011.11 Installation and Operation Guide Bosch Security Systems, Inc.

ARP Cache Timeout

When the B420 communicates with any device on a network, an entry is added to its ARP

table for each of those devices. The ARP Cache Timeout defines the number of seconds (1 to

600) before the ARP table of the B420 is refreshed.

3.9 Panel Address Setting Page

Figure 3.5 shows the Panel Settings web page.

Figure 3.5 Panel Setting Web Page

Use this option to select the bus address for the control panel type that the module is

connected to. Refer to Table 2.1, Page 8.

Default: 600Selection: 1 to 600 (in 1-sec increments)

NOTICE! The Panel Address Setting option only works when the address rotary switch on the B420 is

set to 0 (local configuration setting). Refer to Figure 1.2, Page 6 for the location of the address

rotary switch.

Page 21: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

Ethernet Communication Module Configuration | en 21

Bosch Security Systems, Inc. Installation and Operation Guide F01U215236 | 02 | 2011.11

3.10 Encryption Setting PageFigure 3.6 shows the Encryption Setting web page.

Figure 3.6 Encryption Setting Web Page

AES Encryption Enable

Use this option to enable or disable AES (Advanced Encryption Standard) encryption on the

B420.

AES Key Size

Use this option to select the AES key size. Changing the key size from the default of 128 is not

supported in this version.

AES Key String/Encryption Keys

Configure the AES Key Strings as ID numbers in Remote Programming Software (RPS) using

the Encryption Key tab of the System Configuration dialog box.

Enter the encryption key using 32 hexadecimal characters.

Default: NoSelection: Yes or NoYes All communication through the network module is encrypted. AES

encryption must also be set at the central station receiver and the PC

running RPS.No All communication through the network module is unencrypted.

Default: 128Selection: 1 or 128

Default: 01-02-03-04-05-06-07-08-09-10-11-12-13-14-15-16Selection: Thirty-two hexadecimal characters represented by an ID (1 to 100)

Page 22: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

22 en | Configuration Ethernet Communication Module

F01U215236 | 02 | 2011.11 Installation and Operation Guide Bosch Security Systems, Inc.

3.11 Maintenance PageFigure 3.7 shows the Maintenance web page.

Figure 3.7 Maintenance Web Page

Web Login Password

Enter the password to log in to the configuration web pages. It is recommended to change the

default login password to ensure configuration settings. It is recommended to change your

password for security of the module configuration.

Web Access Enable

Enable or disable access to the configuration web pages.

Panel Programming Enable

NOTICE!

The Enhance Security Enable option is not supported in this version.

Default: B42V2Selection: Four to ten alphanumeric characters

Default: YesSelection: Yes or NoYes Web configuration is enabledNo Web configuration is disabled

NOTICE! Do NOT disable web access unless you are on a SDI2 panel with Panel Programming enabled.

With SDI and Option panels, the module can only be configured via the web interface.

Default: NoSelection: Yes or No

Page 23: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

Ethernet Communication Module Configuration | en 23

Bosch Security Systems, Inc. Installation and Operation Guide F01U215236 | 02 | 2011.11

Enable or disable control panel programming for compatible control panels.

Firmware Upgrade Enable

Enable or disable the ability to upgrade the B420’s firmware from the Firmware Upgrade

configuration page.

Module Hostname

Use this parameter to create or change a module hostname. This is the hostname that

represents the module on the network. The hostname can be used to contact the control

panel via RPS over network, or for the purposes of web configuration and diagnostics of the

module.

Unit Description

Use this parameter to create a simple description for the unit.

3.12 Factory Default PageFigure 3.8 shows the Factory Default web page.

Yes Control panel programming is enabledNo Control panel programming is disabled

NOTICE!

Before proceding, ensure that the web browser is not configured to use a proxy server. Refer

to the browser’s online help for instructions on disabling proxy service.

NOTICE!

Do not disable Web Access Enable and Panel Programming Enable. If both are disabled, you

cannot configure the B420.

Default: NoSelection: Yes or NoYes Allows firmware upgrades to the B420 using the network.No Prevents firmware upgrades.

Default: Blank1

Selection: Sixty-four alphanumeric characters1Blank restores the default hostname Bxxxxxx, whereas xxxxxx is the last six digits of the module’s MAC

address.

Default: BlankSelection: Twenty alphanumeric characters

Page 24: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

24 en | Configuration Ethernet Communication Module

F01U215236 | 02 | 2011.11 Installation and Operation Guide Bosch Security Systems, Inc.

Figure 3.8 Factory Default Web Page

You can return the module to the factory default settings by clicking on the Factory Default

menu.

Click Cancel to cancel the factory default reset. If you select Yes, all configuration options are

returned to the factory default settings.

NOTICE!

Returning the B420 to its factory default settings might cause the B420 to terminate the

current web browsing session. If connected to a compatible SDI2 control panel with Panel

Programming setting enabled, the control panel overwrites the factory default settings with

the control panel's settings. To avoid the control panel settings overwriting Configuration

Pages settings, set Panel Programming Enable to No after restoring the module to factory

default, but before pressing Save and Execute.

Page 25: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

Ethernet Communication Module Configuration | en 25

Bosch Security Systems, Inc. Installation and Operation Guide F01U215236 | 02 | 2011.11

3.13 Firmware Upgrade PageTo upgrade the firmware in the B420, select the Firmware Upgrade option from the

configuration home page. The Firmware Upgrade page opens. Refer to Figure 3.9.

Figure 3.9 Firmware Upgrade Web Page

To proceed with the upgrade, click OK. A new web page opens that allows you to locate the

firmware file and upload it to the B420.

NOTICE!

Upgrading the firmware in the B420 might cause the B420 to terminate the current web

browsing session.

Page 26: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

26 en | Configuration Ethernet Communication Module

F01U215236 | 02 | 2011.11 Installation and Operation Guide Bosch Security Systems, Inc.

3.14 Exiting the Configuration Web PageWhen you are finished configuring the B420, select the Save and Execute option. The Save and Execute web page opens. Refer to Figure 3.10.

Figure 3.10 Save and Execute Web Page

To save the configuration changes that you made, click OK. A confirmation message appears.

Figure 3.11 Save and Execute Confirmation

To exit the configuration web page, click Logout, and then close the internet browser

window.

Page 27: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

Ethernet Communication Module Maintenance and Troubleshooting LEDs | en 27

Bosch Security Systems, Inc. Installation and Operation Guide F01U215236 | 02 | 2011.11

4 Maintenance and Troubleshooting LEDsThe B420 provides the following on-board LEDs to assist with troubleshooting issues:

– System status (refer to Table 4.1)

– Serial communication (data bus) (refer to Table 4.2)

– Ethernet communication (refer to Table 4.3 and Figure 4.1)

Refer to Figure 1.2, Page 6 for the location the LEDs.

Table 4.1 Heartbeat LED (Blue) Descriptions

Table 4.2 Data Bus LEDs (Green) Description

Table 4.3 Ethernet Link LEDs Descriptions

Figure 4.1 Ethernet Communication LEDs

Flash Rate FunctionFlashes once every 1 sec Normal State: Indicates normal operation state.3 quick flashes every 1 sec Communication Error State: Indicates a bus communication

error.ON Steady Trouble State: Indicates a trouble condition exists.OFF Steady LED Trouble State: Module is not powered, or some other

trouble condition prohibits the module from controlling the

Heartbeat LED.OFF for 3 sec, then flash

firmware version*

Firmware Version: For example, if the version is 3.2.1, the

LED pulses 3 times and pauses for 1 sec, pulses 2 times and

pauses for 1 sec, and then pulses 1 time. After pulsing the

Firmware version, the Heartbeat LED stays OFF for 3 sec

before indicating the module state.* On power up, the Heartbeat LED stays OFF for 3 sec before indicating the Firmware version. The LED

pulses the major, minor, and micro digits of the firmware version, with a 1 sec pause after each digit.

LED FunctionRX (Receive) Flashes when the data bus receives a message.TX (Transmit) Flashes when the data bus sends a message.

Left (Yellow) LED Right (Green) LED FunctionOFF OFF No Ethernet linkON Steady OFF 10 BASE-T linkFlashing OFF 10 BASE-T activityON Steady ON Steady 100 BASE-T linkFlashing ON Steady 100 BASE-T activity

Callout Description

1 Left (yellow) Ethernet port LED (Ethernet link)

2 Right (green) Ethernet port LED (100 BASE-T)

3 Data bus interconnect wiring connectors

4 Data bus terminals

� ��

Page 28: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

28 en | Maintenance and Troubleshooting LEDs Ethernet Communication Module

F01U215236 | 02 | 2011.11 Installation and Operation Guide Bosch Security Systems, Inc.

Page 29: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can
Page 30: Ethernet Communication Module - Bosch Globalstna.resource.bosch.com/documents/Installation_Guide_all... · 3.1.2 Web-based Configuration ... Failure to follow these instructions can

Bosch Security Systems, Inc.130 Perinton ParkwayFairport, NY 14450USAwww.boschsecurity.com© Bosch Security Systems, Inc., 2011