Ethernet 802 3
-
Upload
mostafa-khairy -
Category
Documents
-
view
226 -
download
0
Transcript of Ethernet 802 3
-
8/2/2019 Ethernet 802 3
1/12
Ethernet 802.3 Physical Layer Topology: Order in which stations receive
bits
Ethernet hubs use a bus topology
Signal is broadcast
All stations receive almost simultaneously
-
8/2/2019 Ethernet 802 3
2/12
Ethernet 802.3 Physical Layer Topology: Order in which stations receive
bits
Early Ethernet standards arranged stations
in a daisy chain Stations broadcast on the chain in both directions
All stations receive almost simultaneously
Original idea of bus
-
8/2/2019 Ethernet 802 3
3/12
Ethernet 802.3 Physical Layer Topology: Order in which stations receive
bits
Ethernet switches use a switched topology
Signal only goes to one station
-
8/2/2019 Ethernet 802 3
4/12
Ethernet 802.3 Physical Layer Ethernet began as a bus network
Some question whether Ethernet switching
is really Ethernet
However, hubs will be disappearing in the
next few years, and almost all Ethernet will
be switched
-
8/2/2019 Ethernet 802 3
5/12
Ethernet 802.3 Physical Layer
Recent Ethernet 802.3 Standards use
Unshielded Twisted Pair (UTP) Wiring or
Optical Fiber
For Small LANs with a Single Hub or
Switch, use UTP Exclusively
-
8/2/2019 Ethernet 802 3
6/12
Physical Layer 802.3 UTP
Standards Ethernet 802.3 10Base-T
Physical layer standard
Created by the 802.3 Working Group
10 Mbps
Baseband transmission
Insert signal directly into wire No channels
T means uses UTP twisted-pair wire
10 Mbps
802.3
-
8/2/2019 Ethernet 802 3
7/12
Physical Layer 802.3 UTP
Standards Ethernet 802.3 100Base-TX
100 Mbps
100Base-TX: Not just 100Base-T because other100Mbps UTP standards were created but werenot used significantly
Ethernet802.3
1000B
ase-T Gigabit Ethernet
Overkill for small LANs
-
8/2/2019 Ethernet 802 3
8/12
Physical Layer 802.3 UTP
Standards Wiring
Unshielded Twisted Pair Bundle of 4 pairs (only uses 2 pairs)
One pair to send
One pair to receive
Terminates in RJ-45 connector
Slightly larger than RJ-11 home phone connector
-
8/2/2019 Ethernet 802 3
9/12
Physical Layer 802.3 UTP
Standards Categories of UTP Wiring
Wiring Quality, Category 3 being lowest
For 10Base-T Categories 3, 4, or 5 are OK
However, most installed wiring is Cat 5
For 100Base-TX, Cat 5 is required
For Gigabit Ethernet,EnhancedCategory 5is recommended, although Cat 5 shouldwork if perfectly installed
-
8/2/2019 Ethernet 802 3
10/12
Physical Layer: 802.3 UTP Standards
Wiring
100 meters maximum UTP distance hub-to-
station or hub-switch
200 meters maximum distance between stations
100 m 100 m
200 m
-
8/2/2019 Ethernet 802 3
11/12
Physical Layer 802.3 Standards NIC-Hub Communication
NIC transmits on one pair (Pins 1&2)
Hub or switch transmits on another pair (Pins 3
& 6)
Other 4 wires are not used
To Hub or Switch (Pins 1&2)
From Hub or Switch (Pins 3&6)
-
8/2/2019 Ethernet 802 3
12/12
Physical Layer 802.3 Standards Upgrading from 10Base-T to 100Base-TX
Need new hub or switch
May have autosensing 10/100 ports that handle
either 10 Mbps or 100 Mbps NICs
Need new NICs
Only for stations that need more speed
No need to rewire This would be expensive