Enviro Technology Services plc
www.et.co.uk
New product development, and the ability to
introduce innovative monitoring solutions to a wide
range of markets and applications, are the hallmarks
of Enviro Technology’s business philosophy. Nowhere
is this more visible than in the field of particulate
monitoring and sampling.
Enviro Technology offers the widest choice of particulate monitoring equipment
in Europe ranging from hand-held particulate counters and monitors through to
network compatible, real-time ambient air dust monitors and gravimetric dust
samplers. For PM10, PM2.5, PM1.0, Sub-PM1.0 and TSP
No fewer than three EU CEN 1234/1-compliant monitors and samplers are included
in the product range: the single-filter ‘Kleinfilter’ (EU Reference Method), the 47/50
15-filter sequential sampler (utilising the ‘Kleinfilter’ pump module), and the SM 200
combined beta-attenuation mass monitor with 40-filter gravimetric sampler.
Continuous particulate analysers in the range include the SM 200 combined mass
monitor and 40 Filter gravimetric sampler and the universally popular BAM 1020,
both of which have been granted 'equivalency' status in the 2005-2006 DEFRA
inter-comparison and are suitable for use on any UK and overseas air quality
network, including the AURN.
Particulate Monitors and Samplers
APPLICATIONS
• Real-time ambient
air quality
monitoring (urban,
rural, roadside)
• Gravimetric
sampling – single
or multiple filters
• Industrial hygiene
monitoring
(Health & Safety)
• Indoor air quality
monitoring (IAQ)
• Clean-room
monitoring
applications
![Page 2: Et pms leaflet](https://reader037.fdocuments.us/reader037/viewer/2022100600/5560f477d8b42aff3f8b47d1/html5/thumbnails/2.jpg)
BAM 1020The BAM-1020 automatically measures and records
the concentration of airborne particulate matter in
real time using the field-proven beta-attenuation
technique.
Internationally approved (US EPA) and capable of
being calibrated against EU CEN 12341 Equipment
Gravimetric Standard, the advanced design
techniques and ultra reliable mechanism provide a
reliable, rugged and flexible system for the
measurement of PM10, PM 2.5 and TSP.
Once set-up is complete, an integral
microprocessor allows fully automatic operation
whilst accurate measurements are assured by the
automatic calibration zero and span check
conducted before each cycle – a feature unique to
this instrument. This constant evaluation of
operation ensures the highest quality data recovery
of any instrument of its type.
Simple to operate and maintain, the BAM 1020 is
suitable for stand-alone use or simple integration
into a system set-up.
• Comfortably fits in compact
roadside enclosures
• Unique self-calibration check
• 60 day unattended operation
• On-board data logger enables
logging of other sensors
• UK Equivalent Method*
• US-EPA Approved
* UK EQUIVALENCE
PROGRAMME FOR
MONITORING OF
PARTICULATE MATTER
SM 200The SM 200 is the most
advanced real-time, particulate
analyser/sampler currently
available. The instrument is
unique in that, in one
small, bench or rack-mounted box, it combines a
real-time beta-attenuation mass monitor producing
24-hourly averages of PM10 concentration AND a
40-filter sequential gravimetric sampler collecting
24-hour dust filter samples.
Tested alongside the EU Reference Method and
meeting the requirements of CEN 1234-1 (Gravimetric
Sampling), the SM 200 can be used for any dust
monitoring application, including urban ambient air
quality monitoring, and is suitable and compatible for
use in monitoring networks such as the UK’s
Automatic Urban and Rural network (AURN).
Unlike some other dust analysers that, in the UK,
require a multiplication factor to be applied to data
due to the evaporation of volatile particles lost whilst
passing through the heated collection/measurement
unit, the SM 200 requires no such correction factor
in normal operation.
This is because the SM 200 does not heat the
sample inlet, rather, the sample inlet is surrounded
by an outer jacket in which air at ambient
temperature is drawn, thereby maintaining the
temperature of the particulate matter within the
inlet tube close to ambient. This results in non-
volatilisation of any secondary particles that would
normally be driven off at higher temperatures.
As the SM 200 also includes a CEN-1234-1 equivalent
gravimetric sampler, measurements can be checked
against the sampled filters as an additional quality
control parameter.
This is inherently more accurate than other techniques,
and is unique in that the real-time monitor can be
calibrated against the in-built gravimetric sampler on a
regular basis, on site, therefore ensuring high levels of
data quality assurance and control.
• MCERTS Approved • TÜV Approved
• UK Equivalent Method*
Particulate Monitors and Samplers
Real-Time Ambient Dust Monitors
C BAM 1020
BAM 1020proven EU
equivalency*
*Shown to meet equivalence criteria set out in the report on ‘UK equivalence programme for monitoring of particulate matter’. (See www.airquality.co.uk/archive/reports/cat05/0606130952_UKPMEquivalence.pdf)
![Page 3: Et pms leaflet](https://reader037.fdocuments.us/reader037/viewer/2022100600/5560f477d8b42aff3f8b47d1/html5/thumbnails/3.jpg)
Single Filter “Kleinfilter” LVS-3The LVS3 Small Filter Device is TA Luft and CEN
EN 12341 approved for suspended particulate
matter (SPM), PM10, PM2.5, all dust compounds
and elemental carbon. The associated MVS6
Small Filter Device is identical with the LVS3 but
fitted with a 6m3 vacuum pump and is suitable
for the measurements of dioxin concentrations.
With easy, 3-key, menu-guided operation and
equipped with µ-controller, both devices collect
dust samples on filters in a standard, quality-
assured manner. Activation, sampling duration
and sampling intervals are pre-selectable and each
has a large, illuminated digital display. To facilitate
long periods of monitoring without filter changes,
an 8-fold Sampling System may be incorporated.
Sequential Sampler SEQ47/50Rugged and of lightweight construction, the
SEQ47/50 is designed for the outdoor sampling
of all PM fractions and dust in all temperatures
and environmental conditions.
The unit is operated and controlled by integrated
LVS3 or MVS6 samplers (Kleinfiltergeräte). The
magazines for the blank and sampled filters are
capable of holding 15 filters each. A cooled inlet
system and enclosed sampled filter magazine
ensures no loss of particulate volatile material. Filter
holders are available for filters of 47 and 50 mm.
The PM10 inlet accords to CEN EN 12341.
HVAS 3000The HiVol 3000 High Volume Air Sampler has
been designed with four principles in mind - long
life, minimal maintenance, ease of operation and
superb volumetric flow accuracy.
The HiVol 3000 provides a flexible sampling
platform for the sampling of PM10, PM2.5 or
Total Suspended Particulates and the monitoring
of basic meteorological parameters.
The sampler is microprocessor controlled and
incorporates ambient temperature and pressure
sensors that are used to automatically maintain a
constant volumetric flow rate of typically
67.8m3/hr through a 20 / 25cm filter.
The HiVol 3000 features internal data logging of
temperature, barometric pressure and the volume
of air sampled through the filter. Data from an
optional wind speed and direction sensor may also
be collected and stored. Logged data may be
down loaded through the RS232 port. Current
settings, status and total sample volume and run
time may be viewed on its integral LCD display.
High, Medium and Low FlowParticulate Samplers
Z HVAS 3000
S & L VSingle Filter “Kleinfilter”
LVS-3
C SequentialSamplerSEQ47/50
![Page 4: Et pms leaflet](https://reader037.fdocuments.us/reader037/viewer/2022100600/5560f477d8b42aff3f8b47d1/html5/thumbnails/4.jpg)
MiniVol Portable Air SamplerThe MiniVol offers a versatile, cost-effective
solution for monitoring PM10, PM2.5, TSP and
gaseous pollutants. Compact, lightweight and
constructed from durable PVC, the MiniVol is
ideal for sampling air quality in remote locations.
The unit will operate from either
AC or DC power supply whilst an
integral, rechargeable, lead-acid
battery pack will provide up to 24
sampling hours. The slim profile
of the unit enables discreet
mounting and the small size and
low noise output makes it ideal for monitoring
air quality in the work place or public facility.
E-SamplerThe E-Sampler is the most feature-packed
light-scatter Aerosol Monitor available. Whatever
your monitoring need the E-Sampler will provide
accurate, dependable and relevant data. The
E-Sampler is a dual technology instrument that
combines the unequalled real-time measurement
of light scatter with the accuracy standard of filter
methods. The simple filter loading process testifies
to the seamless blending of both technologies.
Aerocet 531Particulate Mass Monitor and Particle counting in
a single unit. The 531 combines hand-held
portability with highly precise measurements.
Data records are stored in memory and may be
transferred to a PC using the supplied software or
printed using the optional portable printer.
A remarkably flexible, higher performance
instrument featuring:
• Operates as either a particulate counter
or mass monitor
• Battery-operated, hand-held
• Two channel particle counter
• PM1, PM2.5, PM7, PM10 or
Total Suspended Particulates
As a mass particular monitor, particles are
detected, sized and counted in multiple size
ranges. Mass conversion is made using standard
conversion factors, or by using user-programmable
factors based on unique conditions. The particle
mass can be displayed as PM1, PM2.5, PM7,
PM10 or Total Suspended Particulates.
When configured as a particle counter, size-based
particle counts are displayed as cumulative
(counts above threshold) above 0.5 and 5.0
microns, the two most popular size ranges.
Particulate Monitors and Samplers
www.et.co.uk
Monitoring for Life
EnviroTechnology Services plcAdvanced Environmental Systems - Sales, Hire and Services
Kingfisher Business Park, London Road, Stroud, Gloucestershire, GL5 2BYTel: +44 (0)1453 733200 Fax: +44 (0)1453 733201 Email: [email protected]
Portable Air Samplers
Laser ParticulateAnalysers
Z E-Sampler