ET-PDL INSTRUCTIONS & TEMPLATE · 2016-12-20 · ET-PDL Trilogy ® Panic Exit Device Trim...

1
ET-PDL Trilogy ® Panic Exit Device Trim INSTRUCTIONS & TEMPLATE Marks Model M9900 Rim Exit Device To Change Cylinder Alarm Lock Systems, Inc. A division of the NAPCO Security Technologies, Inc. 345 Bayview Avenue, Amityville, NY 11701 Tel: (631) 789-4871 Fax: (631) 789-3383 www.alarmlock.com Publicly traded on NASDAQ Symbol: NSSC 1. Existing Installations: Remove the existing Exit Device from the door. Position Alarm Lock template (on this sheet) on the horizontal & vertical lines of the existing spindle hole. New Installations: Use the Marks template to mount the Marks Exit Device on the door. Remove Exit Device and use the Alarm Lock template (on this sheet) to locate and line up the template with the horizontal and vertical lines indicated and tape on the door. Existing and New Installations: Mark all hole centers on each side of door (four "THRU-BOLT HOLES", one "SPINDLE HOLE" and one "WIRES HOLE"). Drill all holes from both sides of door to avoid splinter- ing. Drill all thru holes STRAIGHT through the door. 2. Position Exterior Assembly on door (shown above). 3. Replace Exit Device and fasten with four #8-32 x 1¾" Phillips pan head screws and washers (do not over-tighten). Pull wires through Battery Mounting Plate (do not pinch or cut wires) and position Battery Mounting Plate a minimum of 1/8" above Exit Device, and fasten with four #8 x 3/4" "combination" flat head screws. Check lock for proper operation before closing door. A. Remove Cover plate. Rotate the spindle either direction to expose and remove cylinder screws. B. Remove old cylinder and insert new cylinder. C. Note: The tailpiece must be in the horizontal position as shown in the image above. A B TailPiece IMPORTANT: When replacing cylinder be sure to use the proper Cylinder Adapter and Tailpiece. Battery Cover C C VERTICAL LINE TWO THRU- BOLT HOLES 5/16" DRILL BOTH SIDES SPINDLE HOLE 1" MINIMUM DRILL BOTH SIDES HORIZONTAL LINE WIRES HOLE 3/4" DRILL BOTH SIDES 4.84" 7.00" 3.50" TWO THRU- BOLT HOLES 5/16" DRILL BOTH SIDES 1.375" Marks Model M9900 © 2013 Alarm Lock Systems, Inc. WI 2051-M99 02/13 4 4 4 ETDL SERIES ETPDL SERIES Note: The Spindle Hole must be no less than 1" diameter. 1 1 Vertical Line Horizontal Line 2 2 3 Four Four #8 #8 - - 32 x 1¾" 32 x 1¾" Phillips pan Phillips pan head head screws screws , with , with washers washers Four #8 X 3/4" Four #8 X 3/4" "combination" flat "combination" flat head screws head screws 1/8" 1/8" min. min. 4. Connect the Battery Pack (batteries may be shrink wrapped or may be inside a self- contained housing) and secure inside the Battery Cover with the hook and loop fas- tener (provided). Position the Battery Cover and fasten with four #6-32 x 5/16" screws. Fasten Exit Device Cover and fasten with the four screws provided (as detailed in the Marks installation instructions). Exit Device Cover

Transcript of ET-PDL INSTRUCTIONS & TEMPLATE · 2016-12-20 · ET-PDL Trilogy ® Panic Exit Device Trim...

Page 1: ET-PDL INSTRUCTIONS & TEMPLATE · 2016-12-20 · ET-PDL Trilogy ® Panic Exit Device Trim INSTRUCTIONS & TEMPLATE Marks Model M9900 Rim Exit Device To Change Cylinder Alarm Lock Systems,

ET-PDL Trilogy® Panic Exit Device Trim

INSTRUCTIONS & TEMPLATE

Marks Model M9900

Rim Exit Device

To Change Cylinder

Alarm Lock Systems, Inc. A division of the NAPCO Security Technologies, Inc. 345 Bayview Avenue, Amityville, NY 11701 Tel: (631) 789-4871 Fax: (631) 789-3383 www.alarmlock.com

Publicly traded on NASDAQ Symbol: NSSC

1. Existing Installations: Remove the existing Exit Device from the door. Position Alarm Lock template (on this sheet) on the horizontal & vertical lines of the existing spindle hole.

New Installations: Use the Marks template to mount the Marks Exit Device on the door. Remove Exit Device and use the Alarm Lock template (on this sheet) to locate and line up the template with the horizontal and vertical lines indicated and tape on the door.

Existing and New Installations: Mark all hole centers on each side of door (four "THRU-BOLT HOLES", one "SPINDLE HOLE" and one "WIRES HOLE"). Drill all holes from both sides of door to avoid splinter-ing. Drill all thru holes STRAIGHT through the door.

2. Position Exterior Assembly on door (shown above).

3. Replace Exit Device and fasten with four #8-32 x 1¾" Phillips pan head screws and washers (do not over-tighten). Pull wires through Battery Mounting Plate (do not pinch or cut wires) and position Battery Mounting Plate a minimum of 1/8" above Exit Device, and fasten with four #8 x 3/4" "combination" flat head screws.

Check lock for proper operation before closing door.

A. Remove Cover plate. Rotate the spindle either direction to expose and remove cylinder screws. B. Remove old cylinder and insert new cylinder. C. Note: The tailpiece must be in the

horizontal position as shown in the image above.

A B

TailPiece IMPORTANT: When replacing cylinder be sure to use the proper Cylinder Adapter and Tailpiece.

Battery Cover

C C

VE

RTI

CA

L LI

NE

TWO THRU-BOLT

HOLES 5/16"

DRILL BOTH SIDES SPINDLE

HOLE 1" MINIMUM DRILL BOTH

SIDES

HORIZONTAL

LINE

WIRES HOLE 3/4"

DRILL BOTH SIDES

4.84"

7.00"

3.50"

TWO THRU-BOLT

HOLES 5/16"

DRILL BOTH SIDES

1.375"

Marks Model M9900

© 2013 Alarm Lock Systems, Inc.

WI 2051-M99 02/13

444

ETDL SERIES

ETPDL SERIES

Note: The Spindle Hole must be no less than 1" diameter.

11

Vertical Line

Horizontal Line

22

3

Four Four #8#8--32 x 1¾" 32 x 1¾" Phillips pan Phillips pan

head head screwsscrews, with , with

washerswashers

Four #8 X 3/4" Four #8 X 3/4" "combination" flat "combination" flat

head screwshead screws

1/8" 1/8" min.min.

4. Connect the Battery Pack (batteries may be shrink wrapped or may be inside a self-contained housing) and secure inside the Battery Cover with the hook and loop fas-tener (provided). Position the Battery Cover and fasten with four #6-32 x 5/16" screws.

Fasten Exit Device Cover and fasten with

the four screws provided (as detailed in the Marks installation instructions).

Exit Device Cover