Our Commitment to Customers

Onward and Upward!

The world is in constant motion. Every day sees agrowing flow of active people winding its way throughurban landscapes. This flow creates high demands in afast-paced environment, and ThyssenKrupp Elevator'sescalators and moving walks convert chaos into simplepleasure.

Escalators and moving walks are an indispensable partof a mobile society. Whether in department stores, trainstations, modern stadiums, luxury casinos, hotels, officecomplexes or airports, ThyssenKrupp Elevator productskeep people moving safely and effectively in virtually allareas of public life.

This brochure has been prepared to introduce you toThyssenKrupp Elevator's escalators and moving walks,while assisting you with the planning of your projects.Our experts look forward to working with you toimplement new and creative ideas.

For additional assistance with your escalator planningneeds, call (877) 230-0303 (toll-free) to reach aThyssenKrupp Elevator sales representative.

Table of Contents

Overview, Duties, Products and Capabilities . . . . . 2-3Commercial Duty Escalator . . . . . . . . . . . . . . . . . .4-5Heavy Duty Escalator . . . . . . . . . . . . . . . . . . . . . .6-7Transit Duty Escalator . . . . . . . . . . . . . . . . . . . . . . . .8Escalator Options . . . . . . . . . . . . . . . . . . . . . . . . . . .9Moving Walks . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10Moving Walks Options . . . . . . . . . . . . . . . . . . . . . . 11Planning for PerfectionOverview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Dimensions and Data . . . . . . . . . . . . . . . . . . . . . . 13Safety Manual . . . . . . . . . . . . . . . . . . . . . . . . . 14-15Layout Options . . . . . . . . . . . . . . . . . . . . . . . . . 16-17Preparations by Others . . . . . . . . . . . . . . . . . . . 18-21Work by Others . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Section and Plan Views . . . . . . . . . . . . . . . . . . . . . 23

Page 3: Escalators Design

Escalator and Moving Walk Overview

3

A range of lighting systems and balustrade profiles make ThyssenKrupp movingwalks the perfect complement for shopping malls, exhibition centers and airports.Its innovative design, coupled with state-of-the-art engineering and technology,gives it exemplary qualities for adapting to the prevailing architecture. Available forboth indoor and outdoor applications

Two models, one distinction. More design features formodern buildings, including under-handrail lighting,stainless steel or custom powder-coated finishes. Allmodels combine attractive design with the latestescalator technology for increased comfort and safety.Available for both indoor and outdoor applications.

Never have high-traffic escalators looked so good. Whether with a glass ormetal balustrade, these Heavy Duty models are made to direct the traffic oftomorrow. Economical, robust, and featuring advanced technology, our HeavyDuty line is designed specifically for high-traffic, higher-rise institutionalapplications. Available for both indoor and outdoor applications.

Our most powerful model. Extremely capable and designedfor reliable 24-hour service, this escalator was designed forsubway and other extreme high-traffic applications,designed with travel heights up to 165'-0" (50 m). FullyAPTA (American Public Transit Association) compliant.Available for both indoor and outdoor applications.

Commercial Duty Escalators Heavy Duty Escalators

Transit Duty Escalators Moving Walks

Page 4: Escalators Design

Restrained and inviting.

Conspicuously discreet: The Velino Commericial Duty escalator features a design oriented,slim line ballustrade. The remarkable lightness of the Velino is due to its 40-inch highbalustrade and innovative, almost invisible, handrail guide which leaves the impressionthat the handrail rides directlyon the glass.

The Velino escalator's culturedreserve and clean lines neverplace it in competition with thesurrounding architecture.Rather, it leaves the architectwith the opportunity to establishcarefully placed accents in bothnew and existing environments.

Remarkable. Dependable. That is what you get from theThyssenKrupp Elevator label.

Commercial Duty Escalator

4 Velino Escalator

Page 5: Escalators Design

Enduring and elegant.

A machine that moves thousands of people every day must be properly equipped to do so.The Velino Commercial Duty escalator is a workhorse, available with a reinforced aluminumunder-handrail profile to take any passenger volume in stride.

The ThyssenKrupp Elevator’sVelino escalator proves thatstability and elegance are notmutually exclusive. Thebalustrade's 3/8" (10mm) thicktempered safety glass panelsand optional under-handraillighting provide the Velinoescalator with striking aestheticswhile it performs under the mostdemanding of conditions.

We have, however, given theVelino escalator more than justan attractive look. It is the mosttechnologically advancedescalator currently available. DualCPU controllers and optionalVVVF drive technology keep theVelino products at the front of theclass.

Commercial Duty Escalator

Velino Escalator 5

Page 6: Escalators Design

Convincing over short and long distances.

With its discreet 40-inch high glass balustrade, the ThyssenKrupp Elevator Tugela escalator fitsperfectly into every environment. As much as it flatters the eye of the observer, it pampers theuser with incomparable ride comfort. This escalator is typically designed for higher-riseapplications [>33'-0" (10058mm)] and locations whereheavy crush loads are the norm,such as convention centers,stadiums and airports. Increasedmotor and chain sizing, combinedwith modified handrail drive andtension carriage design, separatethe Tugela from the Velino productline.

Naturally, the reinforcedbalustrade is made of temperedsafety glass, making it resistant tobumps and knocks from bagsand cases. Moreover, a world ofcustomized options are available,including diverse glass colors andoptional under handrail lighting.

No matter what ideas you have inmind for your heavy-dutyescalator, we assure you thatthese can be realized with theTugela escalator.

Heavy Duty Escalator

6 Tugela Escalator

Page 7: Escalators Design

Always on track for success.

ThyssenKrupp Elevator's Tugela escalator has performance and efficiency that are evidentfrom a distance. But to regard it as a pure power packet would do it an injustice: its availablestainless steel, high-deck balustrade design adorns every enclosed environment.

Constructed for demandingoperational requirements inlarge transport facilities orunderground railway stations,the Tugela escalator will handleall of your needs.

From tropical climates to themost frigid regions,ThyssenKrupp Elevator hasyou covered. Warm-weatherclimates do not affectTugela’s perfection inperformance. And for cold-temperature areas, we offeran optional integrated heatingpackage to melt ice and snowto assure passenger safety.This feature is available on allThyssenKrupp Escalatormodels.

Our escalators are madeindividually to suit the specificbuilding design parameterswherever they are to be used.

Heavy Duty Escalator

Tugela Escalator 7

Page 8: Escalators Design

The One that sets the masses in motion.

There are moments in the life of an escalator when it would be ill advised to stop; for example,when large numbers of people are taking it by storm. Wherever such moments arise, theThyssenKrupp Elevator Victoria Transit Duty escalator is the ideal solution.

The Victoria Transit Duty escalatoris the strongest, most powerfulThyssenKrupp model. Itspurpose-developed chain withexternal 4" rollers permits risesup to 164'-0" (50 m). With itsspecially reinforced drive system,it is capable of maximumperformance at full-load capacityaround-the-clock.

Minimum failure rates, maximumsafety standards and optimumservicing simplicity allow forproblem-free operation. Nowonder the Victoria isconstantly putting in anappearance at the mostfrequented places in the world:railway stations, airports, subwaystations, and wherever else there'splenty of life—day in, day out.

Available with glass or high deckbalustrades, ThyssenKruppElevator's Victoria product isfully APTA compliant.

Transit Duty Escalator

8 Victoria Escalator

Page 9: Escalators Design

Stainless steel

Anti-friction coated skirts without lighting.

Step variants:

Powder coatedsilver with yellowdemarcation asrequired byASME/ANSI/CSAcodes.

Powder coatedblack grooveswith yellowdemarcation asrequired byASME/ANSI/CSAcodes.

Escalator Options

A Touch of Class 9

Skirt variants - optionally available in stainless steel:

Extremely durable:

Anti-friction coated skirts with skirt-bandlighting.

The robust high deck, metal balustrade cantake almost anything.

Flowing traffic:

The optional signal clearly shows thedirection for a smooth traffic flow.

Skirt brushes:

Factory-installed skirt brushes keeppassengers at a safe distance.

Outer claddingvariants:

Glass

Mirror

Powder coating

Floor plates:

Aluminum black ribbed

Aluminum plain ribbed

Stainless steel structure-etched

Aluminum checker plate

Balustrade deckingprofiles:

Brushed stainless steel

Aluminum

Page 10: Escalators Design

Reliable and resilient.

Airports increasingly play a major role in modern urban life. They are transport hubs for anendless flow of people on a round-the-clock basis. It is therefore no surprise that moving walksmade by ThyssenKrupp are frequently found in these sensitive locations.

The ThyssenKrupp ElevatorOrinoco moving walk, with itscontinuous 40-inch high 3/8-inchthick tempered safety glassbalustrade, takes knocks andbumps from suitcases, bags andluggage carts in stride.

The qualities of this moving walk,however, are not limited to itsexterior attributes. Quality atThyssenKrupp Elevator hasalways been the sum total of allfactors. Hidden away on theinside is new conveyor technologythat delivers the highly reliableesentials to meet present dayrequirements.

A workhorse like this, however,need not look like one. Therefore,a multitude of design optionsallows the moving walk toharmonize perfectly with any typeof architecture.

Moving Walks

10 Orinoco Moving Walk

Page 11: Escalators Design

Stainless steel

Pallet variants:

Powder coatedsilver with yellowdemarcation asrequired byASME/ANSI/CSAcodes.

Powder coatedblack grooveswith yellowdemarcation asrequired byASME/ANSI/CSAcodes.

Moving Walk Options

Moving in Style 11

Skirt variants - optionally available in stainless steel:

Reduced to essentials:

Brushed stainless steel skirts. Black not shown

The Orinoco moving walk newel.

Visual:

The optional skirt-band lighting provides acontinuous line of illumination.

Increased safety:

The balustrade with integrated deflectorsand optional under handrail lighting.

Outer cladding:

Glass

Mirror

Powder coating

Floor plates:

Aluminum black ribbed

Aluminum plain ribbed

Stainless steel structure-etched

Aluminum checker plate

Skirt decking profiles:

Anodized silver

Anodized light gold

Brushed stainless steel

Powder coated

Page 12: Escalators Design

Planning for Perfection.

12 Overview

1. Travel speeds and transport capacities

6000

7000

8000

9000

1000

1100

1200

1300

14000

15000

16000

17000

0 100 (0,5) 150 (0,75) 200 (0,9)

Persons/hourat 40˝ (1000 mm) nominal step width.

practical transport capacity

theore

tical

trans

port

capa

city

Travel speed f/p (m/s)

Escalators and moving walks can continuously move passengers.Consequently, their transport capacity is much greater than that ofelevators.

Travel speed of escalators is limited by code to 100 f/m (.5 m/s). Formoving walks with 0-8 degree inclination, the speed can be increased upto 180 f/m (0.9 m/s).

The chart illustrates the discrepancy between theory and practice: Thetheoretical transport capacity is useful during the selection procedure. Inpractice, only approximately 80% of this figure is achieved.

For example, passengers tend to be hesitant at higher rises and higherspeeds when stepping onto the step or pallet band. Even with larger stepor pallet widths, the possibility to pass is not always utilized. Even so,higher speeds and wider steps or pallets, ensure travel comfort and aconsiderable reduction of travel time.

2. Travel heights and inclinations.

30º

EscalatorsWith a rise of only 6'-0" (1829), an escalator can considerably improveaccess to the building for the visitor. Furthermore, ThyssenKrupp Elevatorhas designed escalators to reach a rise of 164'-0" (50 m). Code limits theinclination angle to 30° in the US and Canada.

Moving WalksInclined moving walks typically used in shopping center and retailapplications are permitted a maximum angle of 12°. For extended traveldistances, e.g. trade fairs and airports, horizontal moving walks whichenable the use of wider pallets are the most efficient option.

a

3. Step and pallet widths.

An optimum choice needs to be made here: Neither excessively wide ornarrow steps [or pallets] represent a balanced ratio between the spacerequired and the transport capacity, between travel comfort and cost.

Based on the cross-sections, you can see the required space of yourescalators and moving walks. A clearance of 1 1/4" (30mm) for installationmust be added to the dimensions on either side of the escalator or movingwalk. The standard escalator step width for the North American market is40" (1000 mm).

NominalEscalator width

Step width

30°

Page 13: Escalators Design

Planning for Perfection

Dimensions and Data 13

Escalators:

VELINO TUGELA

Angle of inclination 30° 30°

Rise Up to 33'-0"0 (10.05 m) Up to 65'-7" (50 m)

Inclination and rise.

Nominal Step Width Truss Width Pit Width Persons per hour100 f/m (0.5 m/s)

24" (600 mm) 3' - 8 1/4" (1124 mm) 3' - 10" (1168 mm) 4500

32" (800 mm) 4' - 4 3/8" (1330 mm) 4' - 6 3/4" (1391 mm) 6750

40" (1000 mm) 5' - 1/4" (1530 mm) 5' - 2 5/8" (1591 mm) 9000

Theoretical transport capacities and dimensions for all escalators.

Moving Walks:

ORINOCO FS 982/983

Angle of inclination 0-6°, 10°, 12° (Max.)

Length Up to 656'-2" (200 m)

Rise (12°) Up to 29'-7" (9 m)1

Inclination and rise.

Nominal Pallet Width Truss Width Pit Width Persons per hour100 f/m (0.5 m/s)

Persons per hour125 f/m (0.65 m/s)

32" (800 mm) 4' - 4 3/8" (1330 mm) 4' - 6 3/4" (1391 mm) 6750 8775

40" (1000 mm) 5' - 1/4" (1530 mm) 5' - 2 5/8" (1591 mm) 9000 11700

48" (1200 mm) 5' - 8 1/4" (1734 mm) 5' - 10 5/8" (1794 mm) 11250 14625

56" (1400 mm) 6' - 4 1/4" (1937 mm) 6' - 6 5/8" (1997 mm) 13500 17550

64" (1600 mm) 7' - 1/4" (2140 mm) 7' - 2 5/8" (2200 mm) 15750 20475

Theoretical transport capacities and dimensions for all moving walks.

Note: Greater transport lengths or rises on requestNote: A maximum inclination of 12° is permitted for moving walks. If the pallet width exceeds 40" (1000 mm), a maximum inclination of 6° is permittedby code. Note: For moving walks with 0° inclination, a maximum pallet width of 64" (1600 mm) is permitted.

Code Reference: LatestANSI A17.1/CSA-B44

Page 14: Escalators Design

Planning for Perfection

14 Safety Manual

The entry and exit zone shall be kept clear of all obstacles. The width of the zone shall benot less than the width between the centerlines of the handrail plus 8" (200 mm). Thelength of the zone, measured from the end of the newel, shall be no less than twice thedistance between the centerlines of the handrail. Space shall be provided to accommodateall traffic in the safety zone.

Note: These dimensions are absolute minimums.

x + 8" (200 mm)

2x

x

1. Safety zone.

The use of a railing or an additional deck barricade located at a height of 35" (900mm)prevents people from getting onto the escalator or moving walk from the outside of thebalustrades, when outer decking exceeds 5" (127 mm).

35"

( 900

)

2. Additional deck barricade.

With parallel escalators or moving walks, the maximum distance between thebalustrades can be 4" (120 mm). With a larger distance, an infill panel is required.

Note: According to the diagram, an infill panel must be installed.

3. Infill panels.

Page 15: Escalators Design

Planning for Perfection

Safety Manual 15

Skirt brushes are intended to prevent passenger foot entrapment within the step/skirtrunning clearance. Factory-installed skirt brushes are featured on all ThyssenKruppElevator’s escalators and moving walks.

4. Skirt brushes.

The clearance above the step or pallet band must be at least 7' - 0"(2134 mm) at every location as required by code.

min

. 7'

− 0

" (2

134

mm

)

5. Clear height above steps.

In order for passengers to step safely onto escalators, the step or pallet band must be adequately lit. The ambient building lightingmust be at least 50 Lux along all parts of the step band. ThyssenKrupp offers various additional lighting options.

For example:1. Above the balustrade (under handrail)2. Integrated in the skirt band (skirt lighting)3. At the comb-plates. (Combplate lighting)

6. Lighting.

2

31

1. 2. 3.

Page 16: Escalators Design

Planning for Perfection

16 Installation Possibilities

Examples showing arrangements.

There are various possibilities for positioning escalators in a building. Shown are several examples of the most frequently used arrangements.Depending on the requirement, you can decide whether passengers are to be conveyed quickly from floor to floor or whether they may be leadthrough promotional areas.

ThyssenKrupp escalators are designed so that they can be operated in both directions. That is why at the planning stage, you do notneed to decide the direction of travel.

Side view. Front cross-sectionfrom floor to floor.

Plan view.

Escalators in one direction of travel (continuous): Quickly andeasily, the passengers move from floor to floor through shortchangeover paths.

Side view. Front cross-sectionfrom floor to floor.

Plan view.

Front cross-sectionfrom floor to floor.

Side view.

Plan view.

Escalator in one direction of travel (route interrupted): With thisarrangement, the passengers are guided past promotional areas. To gofrom one floor to the next, they are forced to walk back along the side ofthe escalator.

Escalators for both directions of travel: This arrangement ischaracterized by increased travel comfort for the customers, sinceescalators are available for the upward and downward direction.The promotional areas on both sides of the escalators are givengreater attention.

Page 17: Escalators Design

Planning for Perfection

Installation Possibilities 17

Side view. Front cross-sectionfrom floor to floor.

Plan view.

Plan view.

Criss-cross arrangement: The passengers can get to and from the upper floors quickly andeasily through short changeover paths.

Criss-cross arrangement: Moving walks with top and bottom transitioncurve in criss-cross arrangement.

Side view.

Plan view.

Inclined moving walks in parallel.

Side view.Ramped horizontal moving walks: Where no continuous pit is possible.The inclination of the ramp can be up to 12° [maximum 6° when palletwidth exceeds 40” (1000 mm).]

Side view.

Horizontal moving walk.

Optional 3 flat step configuration [used typicallyfor rises greater than 25' - 0" (7620mm)]

Standard 2 Flat Step Configuration

Side view.

Additional notes:� Upper well ventilation is not required for escalators and moving walks.� A lower pit-floor cut-out is required to house our oil-water separator for outdoor applications.

Moving Walks:

Page 18: Escalators Design

Planning for Perfection

18 Preparations by Others

1. Installation timing.

Whenever possible, schedule escalator delivery to take place prior tothe installation of subsequent floor slabs, ceilings, roofs and any otheroverhead impediants.

2. Access openings, transport route load capacity.

Normally, escalators / moving walks are moved in by crane through asuitable overhead opening. Another option is to bring the escalator /moving walk in through a suitable opening at the ground floor. It isimportant that the route to the assembly location within the building isfree of obstacles and level, and the ceiling can support a hoist load of8992 lb (40 KN). Otherwise, appropriate shoring must be provided.

Perfect planning also includes optimum installation planning. That iswhy on the following pages we have listed everything that needs to beplanned and carried out on site to ensure easy installation of yourescalators and moving walks.

Minimum building access opening of 11'-6" (3.5 m) x 11'-6"(3.5 m).

An escalator [e.g. with a travel height of 17'-6" (5.3m)], at an angle of30°, weighs 17,747 lb (8050 kg). The floor of the building must bearthe transport weight of your escalator. Otherwise, additional floorunder-pinning support will be required during the installation period.

Page 19: Escalators Design

Planning for Perfection

Preparations by Others 19

3. Special delivery.

In order to deliver your system into the building and to assemble it readyfor use in a timely manner, take note of the following during the planningstage:

AB C

Completely assembled escalator. Dimensions TBC.

Transport length LTransport height A: with balustrade

B: with balustrade removedC: balustrade only removed from the upper section

E D G F

Split escalator. Dimensions TBC.

Transport height D: with balustradeE: without balustradeF: with balustradeG: without balustrade

4. Overhead openings.

A ThyssenKrupp representative will notify you of the location and size ofthe required ceiling/roof openings. Please ensure the required openingdimensions are made available.

5. Top and bottom supports. (Seismic zones vary)

When designing the support recesses please take into account the supportloads. They are shown on the installation drawing, i.e. at those locationswhere the supports of your escalator (or your moving walk) will be placed.The supports must be able to bear the weight of the escalator including 5 KN/m2 traffic load. When preparing the supporting structures, thedimensions and reactions indicated on our installation plans must beprecisely adhered to.

8˝ (200 mm)

5½˝ (140 mm)

2 3/8̋ (60)

Hardwood blockand steel shim-stock byThyssenKrupp.

Side view throughthe support with

details(Non-Seismic)

Some escalators / moving walks are so long that they have to beinstalled in sections. In this case, ThyssenKrupp manufactures a splitescalator / moving walk at the factory and join the truss sectionstogether on site.

In most cases it is not possible to bring the complete escalator /moving walk into the building. In this case the balustrades will bedismantled before delivery of the escalator / moving walks.

Page 20: Escalators Design

Planning for Perfection

20 Preparations by Others

6. Intermediate supports.

Intermediate supports are needed on escalators with considerable travelheights and on long moving walks. A ThyessenKrupp representative willinform you if an intermediate support is required and will assist withdetermination of its location.

Typically, an intermediate support is required: 2 flat steps design: H>26'-6" (8077 mm)3 flat steps design: H>24'-10" (7569 mm)

H

Pick-up points with wooden beam

steel tube

wooden beam100 X 100 mm

stable concrete

2 drill holes inthe concrete

Pick-up points with threaded rods

steel plates

stable concrete

2 drill holes inthe concrete

2 nuts withwashers

threaded rod

7. Pick-up points by others.

You will be responsible for fitting pick-up points for hoisting and supporting the escalator during assembly. These should be located exactlyabove the center of the supporting points. For systems with several supporting structures please plan for additional pick-up points above theintermediate supports. All pick-up points must be capable of handling a load of 11240 lb (50 KN).

8. Truss cladding.

The exterior cladding of the truss (unless otherwise specified) is by others. The weight of cladding should not exceed 10 lb/ft2 (48.82 kgf/m2).

••

Page 21: Escalators Design

Planning for Perfection

Preparations by Others 21

9. Electrical connection.

Our diagram shows where escalators and moving walks are connected tothe power supply. Power supply is always located at the upper well. Pleasenote that electrical cables are inserted at a distance of 1'-6" (450 mm) onthe side of the support and that the length of the cable on the inside of theescalator must be about 5'-0" (1500 mm). With complex controls, such asthose usually required for escalators and moving walks in transitinstallations, the escalator control equipment may be installed in aseparate room. The power supply cable must be installed in this separatecontrol room. In case of additional soffit lighting, a separate power supplymust be provided in time. The power connection must be provided by anauthorized electrician assigned by the owner’s representative.

~7 7/8"(~200 mm)

~7 7/8"

(~200 mm)

5' - 0"(1500 mm)

1' - 6"(450 mm)

2' - 7 1/2"(800 mm)

Sprinkler

10. Sprinkler piping.

An optional safety feature is the installation of a sprinkler piping within theescalator or moving walk.

11. Oil separator.

A type-proofed oil separator is essential for escalators and moving walkswhich are designed for outdoor exposure. ThyssenKrupp supplies anoil/water separator in the lower well for all outdoor-exposure products. Atthe construction site, a recess and drain must be provided for the oilseparator in the pit.

4' - 7 1/4"(1400 mm)

1' - 11 5/8"(600 mm)

3' - 9 1/4"(1149 mm)

min. 4" (101 mm)

*

12. Railing by others.

In the threshold areas of the escalators, a railing must be installed byothers. The distance to the escalator handrail must be at least 4" (101 mm).

* Ornamental protective handrail by others, height determined bylocal code. Typically: 42" (1067mm)

Page 22: Escalators Design

EscalatorsA. Provision of proper building

dimensions and suitable flooropenings, properly framed withsuitable reactions and finished inaccordance with escalator shopdrawings. Variations not to exceed 1”at any point.

B. Support structure for the escalatorsand enclosure walls, external railing,guards, closures, shutters and smokebarriers as required.

C. Waterproof lower well space andprovide lower pit drainage (asrequired).

D. Fire-rated exterior cladding of trussand finish from the edges of escalatordeck covers, including ends, sides andbottom of truss in accordance withapplicable and standard weightrestrictions. (max. 10 lbs. per squarefoot)

E. Access panels or doors to interior ofescalator if required by unusual layoutconditions.

F. Provision of flexible in-fill and finishedflooring adjacent to floor plates andescalator after installation.

G. Cutting of floors, walls, ceilings orpartitions together with any repairsmade necessary by such cutting.

H. Painting and finish work requiredbeyond that included in this section.

I. Electrical service to upper well toinclude 3 phase main power supplyand fused disconnects to eachcontroller. Provide single phase 120VAC electrical service and fuseddisconnect for light and convenienceoutlet in the upper well and all otherelectrical devices that are not a part ofthe escalator proper that may berequired by local authorities.

J. Provision of wiring and conduit fromthe closest wellway of each escalatorgroup or single escalator to thefirefighter’s control room and/orconsole as required. Co-ordinate withEscalator contractor for size, numberand location of conduit.

K. Other work required for installation ofthe escalator(s) including, but notlimited to, required changes tosprinklers, lighting, electrical, airconditioning and heatingsystems.Provide barriers for openwellways during construction perOSHA Regulations.

L. Protect escalator truss, steps, landingplates balustrades, handrail, andspecial metal finishes from damageduring construction

Moving Walks

A. Provision of proper buildingdimensions and suitable flooropenings, properly framed withsuitable reactions and finished inaccordance with moving walk shopdrawings. Variations not to exceed 1”at any point.

B. Support structure for the moving walksand enclosure walls, external railing,guards, closures, shutters and smokebarriers as required.

C. Waterproof lower well space andprovide lower pit drainage as required.

D. Fire-rated exterior cladding of trussand finish from the edges of movingwalk deck covers, including ends,sides and bottom of truss inaccordance with applicable andstandard weight restrictions. (max. 10lbs. per square foot)

E. Access panels or doors to interior ofmoving walk if required by unusuallayout conditions.

F. Provision of flexible in-fill and finishedflooring adjacent to floor plates andmoving walk after installation.

G. Cutting of floors, walls, ceilings orpartitions together with any repairsmade necessary by such cutting.

H. Painting and finish work requiredbeyond that included in this Section.

I. Electrical service to upper well toinclude 3 phase main power supplyand fused disconnects to eachcontroller. Provide single phase 120VAC electrical service and fuseddisconnect for light and convenienceoutlet in the upper well and all otherelectrical devices that are not a part ofthe moving walk proper that may berequired by local authorities.

J. Provision of wiring and conduit fromthe closest wellway of each movingwalk group or single moving walk tothe firefighter’s control room and/orconsole as required. Coordinate withmoving walk contractor for size,number and location of conduit.

K. Other work required for installation ofthe moving walks(s) including, but notlimited to, required changes tosprinklers, lighting, electrical, airconditioning and heating systems.Provide barriers for open wellwaysduring construction per OSHARegulations.

L. Protect moving walk truss, steps,landing plates balustrades, handrail,and special metal finishes fromdamage during construction

Work by others

22 Escalators and Moving Walks

Page 23: Escalators Design

α

Tan αL =

H+ 15’ (4572) + 5” (127)

7’-3” (2209.8)

1’-10 7/8” (581)

H3’

-9 1

/4”

(115

0)

3’-3

3/8

”(1

000)

3’-5

3/8

FFL

7 7/

8”(2

00)

1’-11 5/8” (600)

Cavity for optional oil separator

14’-1 1/4”(4299 ) at 30˚

7’ m

in.

(213

3.6) 3’-3

3/8

”(1

000

)

3’-1”

(939.8 )optional water discharge

7 7/

8”(2

00 )

E 1’-5 3/4”(450.9)

FFL

3’-9

1/4

”(1

150)

1’-10 7/8”(581)

8’-2” (2489.2)

(105

0)

3’-3

3/8

”(1

000.

1)

Escalator and Moving Walk

Section and Plan Views 23

3´ - 5 5/16˝

1 ́- 7 1/2˝

23´ - 0˝

5´ - 2˝

R4

E

C

Holes for lifting tackle size 04˝

Load: 11 kips per hole

UPPER END (Drive)

BA

3´ - 1 3/8˝

R3

L - (10´ - 4˝)

L -= LengthLOWER END (TENSION)

Holes for lifting tackle size 04˝

Load: 11 kips per hole

Holes for lifting tackle size 04˝

Load: 11 kips per hole

R2R1

3´ - 3 1/2˝

3´ - 5 5/16˝

1´ - 7 1/2˝

5´ - 2˝

23´ - 0˝

- 9

1/4

˝

System Line8˝

1´ - 5 5/16˝ 1´ - 10˝

K L M

24" 3' - 8 1/4" 7' - 7"

32" 4' - 4 1/4" 8' - 11"

40" 5' - 0 1/4" 10' - 3"

1 1/2˝

3 15/16˝

2 3/8˝

1 3/8˝

Finished

floor

Flexible infill by others

5 1

/2˝

Hardwood block and

steel shim-stock by

ThyssenKrupp

Escalator and Moving WalkUpper and Lower Support Detail(Non-seismic)

Escalator Section View

Escalator/Moving Walk Plan View

Escalator Dimensions

Moving Walk Section View

K L M A B C

40" 5' - 0 1/4" 10' - 3" < 39' - 8" < 39' - 8" < 39' - 8"

48" 5' - 8 1/4" 10' - 11" < 42' - 3" < 42' - 3" < 42' - 3"

56" 6' - 4 1/4" 11' - 7" < 45' - 3" < 45' - 3" < 45' - 3"

Moving Walk Dimensions

Page 24: Escalators Design