Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm
Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield Medical School
Consultant in Obstetrics and Fetomaternal MedicineClinical Lead, Wesfield Fetomaternal UnitJessop Wing, Sheffield Teaching Hospitals
Sheffield UK
![Page 2: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/2.jpg)
Outline• Definitions• Scope and classification of prenatal diagnostic
errors• Epidemiology of errors – Relative prevalence– Contribution of system failures– Contribution of individual and patient-related errors
• Strategies for preventing, investigating and mitigating errors in prenatal diagnosis
![Page 3: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/3.jpg)
![Page 4: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/4.jpg)
What is a clinical error?• Failure of a planned action to be completed
as intended, or the use of a wrong plan to achieve an aim.
• Clinical intervention– Appropriate but incomplete– Erroneous– Misdirected– Mis-delivered
![Page 5: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/5.jpg)
Classification of prenatal diagnostic (PND) errors
• Individual errors• Latent errors – “errors waiting to happen”– system failures: faulty systems, processes,
and conditions
![Page 6: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/6.jpg)
Domains of PND errors
• Diagnostic • Treatment • Preventive • Others- latent errors
![Page 7: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/7.jpg)
Diagnostic • Error/delay in diagnosis: fetal malformation
or disease • Failure to employ indicated tests (e.g.
amniocentesis, chorionic villus sampling)
![Page 8: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/8.jpg)
Diagnostic (2) • Use of outmoded tests or therapy – (e.g. inferior prenatal screening tests for aneuploidy
with poor sensitivities and high false positive values)• Failure to act on results: of monitoring/testing– Suggestion of fetal compromise and risk of in utero
demise– Poor interpretation of antenatal surveillance CTG)– Failure to act on +ve test, failure to stop acting on a –
ve test
![Page 9: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/9.jpg)
Treatment• Error in performance of
operation/procedure/test– procedure-related fetal trauma– miscarriage from invasive testing/therapy– system failures in batch prenatal screening for
aneuploidy– Computer errors– technical errors in sample retrieval for genetic
investigations
![Page 10: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/10.jpg)
Treatment (2)• Error in administering treatment – treating the “wrong” unaffected fetus in multiple
pregnancy– Fetal trauma
• Error in dose or method of drug• Delay in treatment/response to an abnormal
test • Inappropriate (not indicated) care
![Page 11: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/11.jpg)
Preventive• Failure to provide prophylaxis– maternal Rhesus sensitisation from failure to
administer prophylactic anti-D following potential fetomaternal haemorrhage
• Inadequate monitoring or follow-up of treatment– Managing the small fetus on scan
![Page 12: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/12.jpg)
Other system failures
• Failure of communication • Equipment failure– resuscitation equipment– cytogenetic and molecular genetics
• Other system failure
![Page 13: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/13.jpg)
SPECIFIC ERRORS
![Page 14: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/14.jpg)
Specific errors
Prenatal screening
Prenatal diagnosis
Prenatal treatment
interventions
![Page 15: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/15.jpg)
Errors during prenatal screening• Incidence data sparse eg universal Downs’
syndrome screening, offered all pregnant women as standard antenatal care.
• Mistakes occur in relation to:– Counselling: failure to offer recommended
testing– Sampling– Laboratory testing and quantification
![Page 16: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/16.jpg)
Errors during prenatal screening– Pregnancy dating • Wrong dates, wrong risks for aneuploidy
– Wrongly filled Lab forms– Wrong assessment of nuchal translucency by US
Errors may lead to false positive or negative results
Would in turn affect parental uptake of diagnostic testing
![Page 17: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/17.jpg)
Typically, legal cases on antenatal screening can arise from failure to offer screening or failure, at the fetal abnormality scan, to identify certain defects.Fetal abnormality screening claimsFor free, expert advice on making a medical negligence claim, click here or call us free on 0800 0382 382. We are available to take your call twenty four hours a day, seven days a week.If you want to provide some details to us in advance, why not let us assess your claim now.
![Page 18: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/18.jpg)
Errors during prenatal diagnosis• Ultrasound errors– 1st trimester errors – dating, anomalies– 2nd trimester errors- the routine anomaly scan– 3rd trimester errors - missed diagnosis not
followed up appropriately– Special circumstances –multiple pregnancies
• Invasive testing errors - cytogenetic and molecular genetics error
![Page 19: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/19.jpg)
Detection rates for fetal abnormalities
![Page 20: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/20.jpg)
UK anomaly detection rates
Bryant L, Fisher A, Vicente F. Social Research and Regeneration Unit A. Fetal AnomalyUltrasound Screening Programme Study: Literature Survey. Plymouth: University of Plymouth Centre; 2007.
![Page 21: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/21.jpg)
Operator-dependent errors, subject/patient dependent errors
• Insufficient skills/training/practice – minimum prescriptions
• Maternal obesity• Fetal position• Oligohydramnios vs. renal agenesis
![Page 22: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/22.jpg)
Maternal obesity and congenital malformationsPaldini Ultrasound Obstet Gynecol 2009; 33: 720–729
![Page 23: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/23.jpg)
Technical factors contributing PND errorsAcoustic limiting factors • Depth of insonation required• Absorption of US energy (dropout)
by abdominal adipose
![Page 24: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/24.jpg)
Tips for scanning obese women
Other remedies• Fetal MR scans• Amnioinfusion for oligohydramnios
![Page 25: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/25.jpg)
Costs of errors in prenatal diagnosis
Pregnancy losses
Survival with morbidity
Additional care necessitated by
errors
Lost income and household
productivityDisability
Loss of trust in health care
system
Diminished satisfaction, patients and
professionals
![Page 26: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/26.jpg)
Consequences of prenatal diagnostic errors
• Erroneous counselling, • Wrong/inappropriate treatment options • Wrong parental decisions
![Page 27: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/27.jpg)
Serious Incident• Definition: an incident that occurred in
relation to services and care resulting in one of the following:– Unexpected/avoidable death of one or more
patients, staff, visitors or members of public.– Serious harm to patient(s), staff, visitors or
members of public or where outcome requires life-saving intervention, major surgical/medical intervention, permanent harm or will shorten life expectancy or result in prolonged pain or psychological harm.
![Page 28: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/28.jpg)
Serious Incident (2)
• A scenario that prevents or threatens to prevent a provider organisation’s ability to continue to deliver healthcare services, for example, actual or potential loss of personal/organisational information, damage to property, reputation or the environment, or IT failure.
![Page 29: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/29.jpg)
Serious Incident- screening• Actual/possible failure at any stage in pathway of
screening service, which:– exposes the programme to unknown levels of risk
that screening, assessment or treatment have been inadequate
– and hence there are possible serious consequences for the clinical management of patients.
• Level of risk to individual may be low, but because of large numbers involved corporate risk may be very high.
![Page 30: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/30.jpg)
ERROR MITIGATION
![Page 31: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/31.jpg)
Failsafe strategies during prenatal screening
• Failsafe: back-up mechanism to ensure that if something goes wrong in screening pathway, processes are in place to (i) identify what is going wrong and (ii) what action follows to ensure a safe outcome.
• Most screening risks/errors predictable and often arise from systems failure than individual error.
• Failsafe aimed to “design out” or reduce errors
![Page 32: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/32.jpg)
Implementation of Failsafe - roles• Assess screening pathway and identified areas of high
risk that require failsafe measures.National:
• Team provide expert advice on reducing risks in local programmes. Assess robustness of local arrangements through audit, peer review and the investigation of incidents.
Regional:
• Incorporate national guidance to reduce risk within service specifications and oversee implementation and functioning.
Commissioners:
• Review and risk assess local pathways against national guidance and develop, implement and maintain risk reduction measures.
Providers:
![Page 33: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/33.jpg)
Downs syndrome screening
![Page 34: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/34.jpg)
![Page 35: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/35.jpg)
Managing serious incidents in screening service
![Page 36: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/36.jpg)
EXAMPLES OF ERRORS LEADING TO LITIGATION
![Page 37: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/37.jpg)
![Page 38: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/38.jpg)
• Mrs. M, gave birth to a son GM. G suffers from Down's Syndrome. It is a matter of admission that this was noted immediately when he was born.
• In this action, the pursuers aver that members of the staff of GRMH (for whom the defenders are vicariously liable) negligently failed to diagnose Gary's condition, and advise the pursuers of it, at the appropriate stage of pregnancy. It is also averred that if the first pursuer had been advised that the baby would be affected by Down's Syndrome, she would have had the pregnancy terminated.
• Damages are claimed, under various heads, in respect of the loss, injury and damage suffered by the pursuers as a result of this negligence. Negligence was admitted.
![Page 39: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/39.jpg)
The standard of care: the tension between medical opinion and parental autonomy
• A patient may say she understands although she has not in fact done so ... It is common experience that misunderstandings arise despite reasonable steps to avoid them. Clinicians should take reasonable and appropriate steps to satisfy themselves that the patient has understood the information which has been provided; but the obligation does not extend to ensuring that the patient has understood.
• Camb. Law J., 70 [2011], pp 523-547 at 538
![Page 40: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/40.jpg)
Maurice and another v France (App no 11810/03) [2005] ECHR 11810/03
• The applicants were man and wife. In 1990, the applicants had their first child who was afflicted by infantile spinal amyotrophy, a genetic disorder. In 1997, the second applicant began her third pregnancy. She requested a prenatal diagnosis, and was assured by the hospital that the foetus was healthy and was not suffering from infantile spinal amytrophy.
• The child was born, and within some two years it became apparent that she did suffer from the condition.
• The applicants subsequently made a claim for compensation for damage suffered as a result of the child's disability. An interim award was made in the applicants' favour.
![Page 41: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/41.jpg)
System failures (1) Millennium incident• In calculation of prior risk the year of birth was recorded
as two digits• After the millennium this resulted in women being
assigned negative ages i.e. approximately -80 to -60 years.
• Patient aged -80 similar to the probability of 14 year old therefore risks calculated did not appear outrageous, several months before decrease in screen positive rate was identified
•
![Page 42: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/42.jpg)
System failures • Subsequent EU directive put Down’s Syndrome
screening software in a high risk category (2) Missing data on request forms • Lab has procedure of Faxing requests forms with
missing data to midwives for completion and return • Some Faxes were not responded to and this was
not realised until it was too late for screening• Labs need to have a robust system in place to chase
request forms with missing data •
![Page 43: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/43.jpg)
System failures(3) Inadvertently altering parameters in Screening software• Down’s risks were affected and were inaccurate for a period
and this led to retrospective recalculation • There needs to be a robust procedure in place whenever
changes are made to any variable which is part of a screening risk calculation algorithm including a change control procedure to check risks on anonymised data sets are the same or show the expected changes pre and post change
![Page 44: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/44.jpg)
Other incidents include: • Misinterpretation of request form information e.g.
a gestation was written on a 2T form as “15.3”. There was no scan information provided so this was interpreted as a HC of 15.3 cm.
• Increase of Fb hCG if samples stored or transported in warm conditions
• Incorrect risks due to donor date of birth not included in IVF Down’s screen
![Page 45: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/45.jpg)
Patients may not recover from a serious error
![Page 46: Errors in Prenatal Diagnosis: Mitigating Risk and Preventing harm Professor Dilly OC Anumba Chair in Obstetrics and Gynaecology, The University of Sheffield.](https://reader034.fdocuments.us/reader034/viewer/2022051316/56649cb45503460f94978020/html5/thumbnails/46.jpg)
Conclusion• Errors do happen but effort should be geared