Eric Magaña, M.D. NM ATS March 3, 2018

Transcript of Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana...

Page 1: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

Eric Magaña, M.D.

NM ATS

March 3, 2018

Page 2: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

Increased WOB due to increased airway resistance

Overcome with Heliox or pressure support

High Peak pressures due to increased airway resistance

Page 3: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

Present an addition theory as to the origins of the high peak pressures in asthma

due to the presence of auto-PEEP

Inspiratory time (Tinsp)

Patient-ventilator dyssynchrony

Use a case review to illustrate

Page 4: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

4

Inflammatory lung disease

Primarily affects larger airways

Edema

Muscle contraction

Excessive mucus

Page 5: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

5

Corticosteroids› About 6 hrs before clinical effect

Beta agonists› Nebulized, oral, IV

Anticholinergics› Ipratropium, Tiotropium

Leukotriene inhibitors/receptor blockers› Montelukast, Zileuton

Intravenous Magnesium

Page 6: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

6

Patients are notoriously difficult to ventilate Patients often require heavy sedation or

paralysis to alleviate dyspnea and improve ventilator synchrony

Page 7: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

7

High Peak Pressures are common

Due to high airway resistance

Volume is dumped due to high pressure

Results in inadequate ventilation and elevated pCO2

Patients are often dyssynchronous (“fighting the vent”) due to set flow pattern.

High pressure, high RR, low delivered tidal volume, low minute ventilation

Page 8: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

8

High driving pressures are needed to achieve adequate tidal volumes

If high driving pressures are used to achieve desired tidal volume, barotrauma can result

› Pneumothorax or pneumomediastinum

Synchrony is often better due to delivery of variable flow

Page 9: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

22 yr female asthmatic presented with a several day history of dyspnea

Increased used of albuterol inhaler without controller medications

Obvious respiratory distress, poor air movement, occasional wheezing

Page 10: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

10

Patient received 5 mg albuterol via nebulizer twice in route

125 mg of solumedrol, 15 mg continuous albuterol neb, .5 mg atrovent, 2 gmsmagnesium

135 pulse, RR=38, afeb, 100/60, diaphoretic

NIPPV failed, patient was intubated and placed on mechanical ventilation

Page 11: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

Volume A/C VT=400 ml RR=19 Peep 3 100%

Ppeak=60, Paralyzed

Pressure A/C RR=19 Tinsp =.5 (to reduce auto-PEEP), ∆P=50 achieving a Vt=350, PEEP=3

pH=6.9, pCO2=80

Page 12: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

12

pCO2 is allowed to rise as long as oxygenation is adequate

› Rather than pushing vent (risking barotrauma) to lower pCO2 to normal

Bicarb drip is sometimes used to maintain normal pH

Page 13: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

13

Page 14: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

14

Bigger airways during inspiration conduct more air than smaller tubes during expiration.

More air gets in than out.

15 L/m go in but only 13 L/m come out.

The lungs become overinflated

Page 15: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

15

PEEP (extrinsic)

› Applied by ventilator in a controlled manner

Auto-PEEP Occult PEEP

Intrinsic PEEP

Dynamic hyperinflation

Air trapping

develops when not all

of the air is exhaled

prior to the inspiration

of the next breath

Page 16: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

16

Page 17: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

Increased intrathoracic pressure

Decreased venous return

Effective hypovolemia

Can increase work to trigger a breath

Can change the position on the compliance curve

Page 18: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

18

The pressure from Auto-PEEP adds to airway pressures generated by the ventilator breath Auto-PEEP

Page 19: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

19

Due to increased airway resistance

Due to alveolar distention

From the tidal volume

Or from PEEP

Page 20: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...
Page 21: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

21

Decreases effective driving pressure in Pressure Ventilation

Ventilator does not know Auto-PEEP is there

Increases work to take a breath

Over and beyond the increase from airway resistance

Page 22: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

Delta P=35, PEEP=5

Ventilator does not think about increasing pressure by 35 during inspiration

During inspiration it maintains the pressure at 40

During expiration it has the pressure at 5

40

Page 23: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

40 cm H20

5 cm H20

25 cm H20

Set PEEP

Actual PEEP

∆P=35

∆P=15

Page 24: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

The pt requires very high Set driving pressures to achieve an adequate tidal volume

the Effective driving pressures are much lower due to the presence of auto-PEEP

Page 25: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...
Page 26: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

The auto PEEP moves the patient up on the compliance curve to a poorly compliant region where the lung is stiff

This requires higher pressures to get the same volume

Page 27: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

RECOGNIZE ITS PRESENCE

Flow-Time curve-baseline not return to zero

estimated end expiratory pause

Decrease tidal volume

Increase expiratory time

Increase the flow

Decrease respiratory rate

Treat cause (bronchodilators)

Page 28: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...
Page 29: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

Tinsp was decreased to 0.5 sec in an attempt to decrease Auto-PEEP

A shorter I time gives more time to exhale

.25 sec more?

Driving pressure has to be raised to get the desired tidal volume in in a shorter period of time

Page 30: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

Short Tinsp was too low to allow for adequate mixing of gases in the alveoli.

pCO2 rose because of this

Soda in fridge analogy

Page 31: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

31

Treat the cause

› Increased airway resistance

You can Compensate for Auto-PEEP.

Compensating for Auto-PEEP rapidly improves symptoms.

Page 32: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

32

0 cm H2O

-5 cm H2O

AIR

-5 cm H2O gradient from alveoli to

mouth is enough to get a breath

Lung

Page 33: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

33

-5 cm H2O

AIR

-5 cm H2O gradient from alveoli to

mouth is enough to get a breath, but 20

cm H2O of effort was needed to get

there (+15 to -5)

Lung

-0 cm H2O

+15 cm H2O

Page 34: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

Takes longer to generate larger pressures

Pt starts to exhale just after a ventilator breath is triggered

Pt ends up exhaling against the breath

In volume, the breath is terminated due to this high peak pressure

Low exhaled volume and minute ventilation alarms

Page 35: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

35

CPAP and PEEP are effectively the same thing

Both expand the lung and recruit alveoli

The name changes depending of if the breath is augment by the vent or not

Page 36: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

36

+10 cm H2O

Air/vent

-5 cm H2O gradient from alveoli to

mouth is enough to get a breath, and 5

cm H2O of effort was needed to get

there (+15 to +10)

+15 cm H2O Lung

Page 37: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

37

Start at 8 cm H2O

8 vs 10

10 vs 12

12 vs 14

After patient calms down, CPAP level often can be reduced

› Due to decrease in Auto-PEEP

Page 38: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

38

Patients may not need augmentation of their breaths once the Auto-PEEP is addressed with CPAP/PEEP

Allowing the patient to breath with just CPAP may result in adequate ventilation and ventilator synchrony

Page 39: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

39

Try CPAP early on in treatment of asthma exacerbation

› Not just when trying to avoid intubation

Dramatically improves dyspnea

› Does not alter airway obstruction

Titrate level for patient comfort

Changing to BiPAP or addition of PSV is sometimes necessary

› Not needed in every patient

Page 40: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

How much PEEP can you add?

Adding extrinsic PEEP to Auto-PEEP does NOT increase total PEEP

sometimes

Page 41: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...
Page 42: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

dropped rate from 22 to 19 which lengthened RCL and increased Tinsp to 0.8 sec

more time for gase mixing

pCO2 dropped

• Lengthening Tinsp allowed lower driving pressures Short Tinsp required higher driving pressures to get

the same volume in a shorter period of time

Page 43: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

Then unparalyzed the patient and used PEEP to overcome Auto-PEEP.

Kept pt in flow variable mode

Pressure mode

PSV=5 with VT≈500, PEEP=17 and comfortable

Page 44: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

I Considered extubating the patient to decrease resistance to expiratory flow and auto-PEEP

Page 45: Eric Magaña, M.D. NM ATS March 3, 2018 · 15 L/m go in but only 13 L/m come out. ... Magana Created Date: 2/28/2018 1:37:29 PM ...

Airway resistance

Short Tinsp required higher pressure to get a decent volume in a very short time

Auto-PEEP

Pt exhaling against the breath