EQUIPMENTS FOR FGSS & ME-GI ENGINES Flyer FGSS System rev0.pdf · EQUIPMENTS FOR FGSS & ME-GI...

8
TECNOCRYO EQUIPMENTS FOR FGSS & ME-GI ENGINES EQUIPMENTS FOR FUEL GAS SUPPLY SYSTEM EQUIPMENTS FOR FUEL GAS SUPPLY SYSTEM EQUIPMENTS FOR FUEL GAS SUPPLY SYSTEM EQUIPMENTS FOR FUEL GAS SUPPLY SYSTEM Equipments, components and skid modules for the Fuel Gas Supply System (FGSS) to dispach the LNG into CNG to the new generation of ME.GI. Engines for ships: Tecnocryo partnership for the capability of: - Full Mechanical Design and Engineering - Equipments definition - All-in-one skid modules - Product Reliability and Quality Equipments: - LNG High pressure pump skids (ME.GI. Skid type) - LNG Vaporizing skids (HTF Skid type) - LNG Vaporizers (CWX Exchanger type)

Transcript of EQUIPMENTS FOR FGSS & ME-GI ENGINES Flyer FGSS System rev0.pdf · EQUIPMENTS FOR FGSS & ME-GI...

TECNOCRYO

EQ

UIP

MEN

TS F

OR F

GSS

& M

E-G

I EN

GIN

ES

EQUIPMENTS FOR FUEL GAS SUPPLY SYSTEMEQUIPMENTS FOR FUEL GAS SUPPLY SYSTEMEQUIPMENTS FOR FUEL GAS SUPPLY SYSTEMEQUIPMENTS FOR FUEL GAS SUPPLY SYSTEM

Equipments, components and skid modules for the Fuel Gas Supply System

(FGSS) to dispach the LNG into CNG to the new generation of ME.GI. Engines

for ships:

Tecnocryo partnership for the capability of:

- Full Mechanical Design and Engineering

- Equipments definition

- All-in-one skid modules

- Product Reliability and Quality

Equipments:

- LNG High pressure pump skids (ME.GI. Skid type)

- LNG Vaporizing skids (HTF Skid type)

- LNG Vaporizers (CWX Exchanger type)

TH

E C

OM

PA

NY O

F

CRYO

GEN

IC G

AS

Tecnocryo S.p.A.

Via Ugo Foscolo 8

20060 Basiano (MI)

Italy

phone: +39.02957641.20

fax: +39.02957641.02

web site: http://www.tecnocryo.com/

e-mail: [email protected]

LNG HIGH PRESSURE PUMP SKID (ME.GI SKID)LNG HIGH PRESSURE PUMP SKID (ME.GI SKID)LNG HIGH PRESSURE PUMP SKID (ME.GI SKID)LNG HIGH PRESSURE PUMP SKID (ME.GI SKID)

Double Cryogenic Pumps skid

Full Mechanical Design

Compactness

Enanched Lifetime

Reliability

Quality

Rules for Ships of any Class or Register

Design

Manufacturing

Installation

Assembly

Testing

Inspection

All in Tecnocryo’s

premises.

Skids delivered

certified by Class for

Ship installation.

Control

cabinet

LNG Cryo

Pump Triplex

Electric motor

GearBox transmission

Mobile

baseframe

Drip tray

For leaks

Pulsation

dampener

Cryo-Piping

For LNG

Quality

TH

E C

OM

PA

NY O

F

CRYO

GEN

IC G

AS

Tecnocryo S.p.A.

Via Ugo Foscolo 8

20060 Basiano (MI)

Italy

phone: +39.02957641.20

fax: +39.02957641.02

web site: http://www.tecnocryo.com/

e-mail: [email protected]

Medium LNG

Flow up to 6200 kg/h (per pump)

Pressure up to 370 barg

Temperature -196°C / +65°C

Power lower than 200 kW (per pump)

Pump speed lower than 340 rpm for long life

Hydraulic eff. More than 85 %

Transmission Lubricated gearbox for long life

Performance

Single Cryogenic Pumps skid

Mobile

baseframe

Cryogenic

pump

Pulsation

dampener

Electric

motor Belts

Transmission

Drip

tray Cryogenic

piping

TH

E C

OM

PA

NY O

F

CRYO

GEN

IC G

AS

Tecnocryo S.p.A.

Via Ugo Foscolo 8

20060 Basiano (MI)

Italy

phone: +39.02957641.20

fax: +39.02957641.02

web site: http://www.tecnocryo.com/

e-mail: [email protected]

Medium LNG

Flow up to 1900 kg/h (per pump)

Pressure up to 420 barg

Temperature -196°C / +65°C

Power lower than 90 kW (per pump)

Pump speed lower than 450 rpm

Hydraulic eff. More than 85 %

Transmission Pulley with timing-belts for easy maintenance

Performance

TH

E C

OM

PA

NY O

F

CRYO

GEN

IC G

AS

Tecnocryo S.p.A.

Via Ugo Foscolo 8

20060 Basiano (MI)

Italy

phone: +39.02957641.20

fax: +39.02957641.02

web site: http://www.tecnocryo.com/

e-mail: [email protected]

LNG LNG LNG LNG VAPORIZER SKIDVAPORIZER SKIDVAPORIZER SKIDVAPORIZER SKID ((((HTFHTFHTFHTF SKID)SKID)SKID)SKID)

LNG Vaporizing Skid (HTF Skid type)

Full Mechanical Design

Compactness

Enanched Lifetime

Reliability

Quality

Rules for Ships of any Class or Register

Design

Manufacturing

Installation

Assembly

Testing

Inspection

All in Tecnocryo’s premises.

Skids delivered certified by Class for Ship installation.

Suction

manifold

Hot Water

heater

loop

Delivery

manifold

Mobile baseframe

Glycol-Water Pump (2)

Drum tank

Water-Glycol

Vaporizer

CWX Type

Quality

Tecnocryo S.p.A.

Via Ugo Foscolo 8

20060 Basiano (MI)

Italy

phone: +39.02957641.20

fax: +39.02957641.02

web site: http://www.tecnocryo.com/

e-mail: [email protected]

Medium LNG to CNG

Glycol-water loop for the LNG vaporization

Hot water as the heat source

Flow LNG up to 6200 kg/h

W-Glycol from 60 to 130 m3/h upon temperature difference

Hot water from 40 to 60 m3/h upon temperature difference

Pressure design at 10 barg for water-glycol and hot water

Temperature between 55°C and 80°C

Power lower than 20 kW (per pump)

Overall size 3m x 3.5 m, height 3.2 m

Performance

TH

E C

OM

PA

NY O

F

CRYO

GEN

IC G

AS

Tecnocryo S.p.A.

Via Ugo Foscolo 8

20060 Basiano (MI)

Italy

phone: +39.02957641.20

fax: +39.02957641.02

web site: http://www.tecnocryo.com/

e-mail: [email protected]

LNG VAPORIZER (CWX EXCHANGER TYPE)LNG VAPORIZER (CWX EXCHANGER TYPE)LNG VAPORIZER (CWX EXCHANGER TYPE)LNG VAPORIZER (CWX EXCHANGER TYPE)

CWX Vaporizer (Coil Wound Heat Exchanger)

Full Mechanical Design

Compactness

Enanched Lifetime

Reliability

Quality

Rules for Ships of any Class or Register

Medium LNG vaporized into CNG

Flow up to 6200 kg/h

Pressure up to 370 barg, up to 420 barg for some model

Temperature -196°C / +65°C

Inlet temp. -155°C +/- 5°C

Outlet temp. 45°C +/- 5°C

Performance Tube Side

Tube Side (LNG to CNG)

Shell Side

(Water-Glycol)

Nozzle for rupture disk

Body flange for maintenance

Water-Glycol outlet

Water-Glycol inlet

CNG outlet

(vaporized gas)

LNG inlet

(from pump)

Tecnocryo S.p.A.

Via Ugo Foscolo 8

20060 Basiano (MI)

Italy

phone: +39.02957641.20

fax: +39.02957641.02

web site: http://www.tecnocryo.com/

e-mail: [email protected]

Medium Water or Water-Glycol

Flow from 60 to 130 m3/h upon temperature difference

Pressure design at 10 barg

Temperature -20°C / + 90°C

Inlet temp. between 70°C and 80°C

Outlet temp. between 55°C and 65°C

Overall size Ø550, height 2.8 m

Performance Shell Side

Cryogenic Stabilization at -196°C With Liquid Nitrogen