Equipment DPDC 2019-20 - e Tenders€¦ · Easy to read display screen No- Zero adjustment Long...

15

Transcript of Equipment DPDC 2019-20 - e Tenders€¦ · Easy to read display screen No- Zero adjustment Long...

Page 1: Equipment DPDC 2019-20 - e Tenders€¦ · Easy to read display screen No- Zero adjustment Long file holder Foot control LCD display – Bright and clear display Multi frequency impedance
Page 2: Equipment DPDC 2019-20 - e Tenders€¦ · Easy to read display screen No- Zero adjustment Long file holder Foot control LCD display – Bright and clear display Multi frequency impedance
Page 3: Equipment DPDC 2019-20 - e Tenders€¦ · Easy to read display screen No- Zero adjustment Long file holder Foot control LCD display – Bright and clear display Multi frequency impedance
Page 4: Equipment DPDC 2019-20 - e Tenders€¦ · Easy to read display screen No- Zero adjustment Long file holder Foot control LCD display – Bright and clear display Multi frequency impedance

Specification 01 . Rubber Dam Kits Components include – Rubber dam clamps, Rubber dam punch, Rubber dam forcep, Template, Frame, Wedgets and Rubber Dam sheets A range of extremely dedicated quality of rubber dam components Nine colour coded clamps to satisfy all the areas of teeth Good quality stainless steel products quite corrosion resistance having good flexibility as well sturdiness Ainsworth type punch having proper plunger and different sizes holes for different sizes tooth punches hole through any gauge dam Wedgets available in kit to push dam sheets in interdental areas and retention for dam. Clamps available as winged as well as wingless Light weight matte finished forceps Latex Dental Dam Elasti-Dam, ready cut, Medium: H11624 Green Heavy: H11675 Green H11626 Blue H11677 Blue Elasti-Dam, ready cut, for adults, 152 × 152 mm, 52 sheets1) Medium: H11625 Green Heavy: H11676 Green H11627 Blue H11678 Blue Non-Latex Flexi Dam® 152 × 152 mm, 30 sheets, for adults Medium: H09945 Purple H09946 Tealgreen

Wedjets 2.1 m Latex* H08040 Extra Small, Blue H06522 Small, Yellow H06523 Large, Orange Non-Latex H06524 Small, Lime Green H06525 Large, H01414 Plastic, for adults (152 mm) H00560 Youngs frame, plastic, for adults H07082 Metal, H07083 Metal, for adults (152 mm) Dental Dam Forceps H01262 stainless steel Dental Dam Punch H01261 stainless steel Ora-Shield Dental Dam Napkins, 50 pieces H01415 fits Frame size 127 mm and 152 mm H00841 Fits Holder (large size) H01443 for adults H01441 for adults DENTAL DAM CLAMPS (stainless steel) Clamp-Kits H02701 System-9-clamp-kit (winged) Size: 1, 2, 4, 7, 8A, 9, 12A, 13A, 14A H01054 Brinker Clamp-Set Size: B1, B2, B3, B4, B5, B6 H09966 Fiesta 9 Winged Color Coded Clamp Pak (Color Coded Clamp Oraganizer and Winged sizes: 2, 2A, 4, 7, 8A, 9, 12A, 13A, 14A) H02801 Fiesta 9W Wingless Color Coded Clamp Pak (Color Coded Clamp Oraganizer and Wingless sizes: W2, W2A, W3, W7, W8, 8A, W9, W14A, W56)

02. Apex Locator 97.5 % accuracy rate Automatic Caliberation Easy to read display screen No- Zero adjustment Long file holder Foot control LCD display – Bright and clear display Multi frequency impedance based measurement technology High precision of apical foramen localisation in wet and dry canals Compact size and stable design 1600 mAh battery

Page 5: Equipment DPDC 2019-20 - e Tenders€¦ · Easy to read display screen No- Zero adjustment Long file holder Foot control LCD display – Bright and clear display Multi frequency impedance

03. Pulp Tester

• Designed for optimal ergonomics and easy handling. • Automatic one-button operation. • Three rates of stimulus increase – slow, medium and fast. • Unit remembers the previous rate of speed programmed. • Micro-processor performs a self-test assuring proper function of the unit every time. • Unit comes with 4 autoclavable probe tips. • Runs on easily replaceable 9-V alkaline battery.

04. Autoclaves For Hand Piece Piece Sterlization

• It should be classifiable as a class- S autoclave for handpieces, turbines and solid instruments which fit in the basket.

• It should contain an absolute pressure sensor. • It should be able to clean, lubricate and sterilize non wrapped as well as wrapped

instruments • It should have the following sterilization programmes :

1. Standard program - 134⁰C for 3 mins, total cycle time approx 16 mins 2. Standard gentle program - 121⁰C for 15 mins, total cycle time approx 24 mins 3. Wrapped program - 134⁰C for 3 mins, total cycle time approx 22 mins

• It should have adaptor for multiple handpieces. • It should have separate lid for wrapped instruments. • It should have separate basket for solid instruments. • It should follow the international standard for washer-disinfectors. • It should have water tank capacity of 2 liters with oil bottle capacity of 0.2 liters.

05. Magnifying Loops

With LED Light High quality TTL (Through the Lens) Loupes TTL Loupes prevents the Fatigue and field disorientation provided by flip up loupes Available in Magnification range of 2.5 X – 4X Having a world quality lens next to Carl Zeiss Customised independently for each person according to the inter pupillary distance Light weight and available in sports model and conventional spectacle pattern

06. Micro-abrasion- System high-quality hand instrument with a wide range of interchangeable Lamineer diamond tipsfor safe and precise finishing work.

• Interproximal adjustments • Marginal adjustments • Overhang reduction Dual Modalities: Fixed or Self-stering Tip

Page 6: Equipment DPDC 2019-20 - e Tenders€¦ · Easy to read display screen No- Zero adjustment Long file holder Foot control LCD display – Bright and clear display Multi frequency impedance

LTA-150/2 * Diamond Red LTA-100/2 Diamond Green LTA-75/2 Diamond Gold LTA-50/2 Diamond Yellow LTA-30/2 * Diamond White LTA-15/2 Diamond Violet LTA-39/2 * Tungsten Black Carbide LTA-F100/2 Diamond Green LTA-F75/2 Diamond Gold LTA-F50/2 Diamond Yellow LTA-E50/2 Diamond Yellow LTA-C50/2 Diamond Yellow LTA-T50/2 Diamond Yellow LTA-T30/2 Diamond White 07. Composite Kits with Different shades and Polishing Kit

Components include Vita shade Guide, 3 syringes of estellite flow quick, bond and Microapplicator tips The original vita shade guide for proper shade matching LX 5 – Supra nano spherical fillers providing outstanding polishability, wide shade matching (chameleon effect) and high wear resistance Quick curing time – 10 second, high gloss retention over time Extended working time 90 second under ambient light Low Shrinkage, good radio opacity 14 syringes – A1 – 2no., A2- 3no, A3- 1, B1- 2, Opaquer- 1, B2- 2, translucent – 2 no, B3- 1no Estellite Flow Quick – innovative initiator system – Radical Amplified Photopolymerisation – reduced curing time without compromising the working time Self etch bond (6 Bottles) – 3D SR monomer creates integrity and uniform bonding giving strong and durable adhesive strength Less post operative sensitivity

08. GP Cutter

Fast heating upto 160oC in 2 seconds. Wireless, flexible and convenient to operate. 2 sets of 4 heating tips of different shapes Time saving Rechargeable battery

09. Needle destroyer Voltage – 220v Frequency – 50 Hz Gauge – 19-31 Low power consumption Compact design Shockproof

Page 7: Equipment DPDC 2019-20 - e Tenders€¦ · Easy to read display screen No- Zero adjustment Long file holder Foot control LCD display – Bright and clear display Multi frequency impedance

10. Ultrasonic Cleaner

Frequency – 40 KHz Power- 50 W Stainless steel tank Capacity – 5 litres Digital display Automatic

Heating digitally controlled 11. ULTRASONIC SCALER • Based on Piezon technology • Detachable Handpiece can be sterilized at 135°C • Works on 3 different modes : Scaling, Perio & Endo • Frequency tracking automatically, sustained • Works at the best frequency point • With 6 Tips • With 1 wrench, Adaptor and foot switch • Gross Weight : 1.5 Kg • Water control button

• Speed control button • 12.Desktop Computer & Printer

• Model No. 190-0302IN • Configuration: i3 8th Generation, 4GB DDR4RAM, 1TB HDD, Win 10, 20” Monitor,

Keyboard, Mouse • 13.Printer • Canon all-in-one Laserjet printer • Model 3010

14.Pediatric Dental chair with accessory (E- type) Dental chair :- (Swiss/German/Brazilian/France/Indian make)

Electrically operated physiological dental chair having easy movements • Weight of Vertical base should not be less than 70 kg to prevent tilting of chair • Right and left arm should be movable • Mounted operating light should be LED with 2 intensity (Switches and sensor) • Should have hand and foot control for up and down movement • Spittoon should be of colored glass with auto, water tumbler which should be ceramic • Should be supplied with embossed color cartoons back rest and sitting area, and stool • Rexin used in chair should be printed with cartoon • Should be supplied with high and low motorized suction (Auto flush, auto drain, sensor

controlled)

Page 8: Equipment DPDC 2019-20 - e Tenders€¦ · Easy to read display screen No- Zero adjustment Long file holder Foot control LCD display – Bright and clear display Multi frequency impedance

• Should have in built LED x-ray unit attach to chair • Stainless steel instrument tray • Up and down movements and back rest movements should be motorized • Should have economically stress free seat and back rest • Should be adjustable with “U” bend grip to provide neck comfort • Should have mounted with high and low lumen intensity of 9v/12 two intensity, • LED LIGHT SHOULD BE WITH MINIMUM INTENSITY OF 30000 LUF • Should have hot and cold water irrigation system • Control box should have the facility of air-rotor, three way syringe and ultrasonic scaler • Should be supplied with fixed autoclavable steel tray of the size of control box on which

it is rest • Two way switch facility for filling the tumbler and flushing the basin .It should have

water filter • Should have internationally accepted design with material (Steel and other as per the

component of ISO/ISI accepted) • Should be coated with good quality transparent plastic for easy cleaning (rexin part)

which should be paediatric friendly • Should be supplied with Euro mould operator stool having bacrest, pneumatic piston for

height adjustment made of up of steel (base • Should incorporate all wires, drainage pipe and suction pipe in vertical component (arm)

of cantilever chair. • Length of back rest should be not more 18 inch and width 16 inch • Length of sitting seat should not me less than 40 inch and width 16 inch. • Should have inbuilt facility of pedi wrap belt to stabilize children legs , hands and body

Inbuilt Fiberoptic Ultrasonic scaler • Should be supplied with inbuilt ultrasonic scaler (Swiss/german/france /brazil) • Power setting should be 4.1 to 14, intermittent duly 5 min to 10 min, vibration and frequency 27

to 33 kHZ, water pressure 1-5 bar (14-72 psi) , Autoclavable tips with hand piece, with medical microriles filter for irrigator.

• Automatic feedback control system adjusting to optimum frequency at tips. Total 9 tips (3 supra-gingival scaling, 2 for sub-gingival, and 4 for implant.

• Should be supplied retractor valve, bottle holder and switch , water controller switches (2 each)

CORDLESS LED light cure (Swiss/german/france /brazil) • Should be cordless with intensity 1000-2000 nm/cm/cube • probe tip should be 9-11mm in diameter, and have 360 degree rotable light cycle • One piece stainless steel cartridge for easy disinfection • Unique ergonomic shape for ease of handling • Eye protection shield for safety

Fiber optic Air rotar Handpiece (2 with each chair) (Swiss/german/france /brazil)

• Should be supplied with two super torque air rotor hand piece having small head with ceramic bearing

• Speed should be 300000-400000 rpm • Oil spray Nozzle should be supplied in each hand piece, compatible with universal coupling

Page 9: Equipment DPDC 2019-20 - e Tenders€¦ · Easy to read display screen No- Zero adjustment Long file holder Foot control LCD display – Bright and clear display Multi frequency impedance

15. ALL N ONE COMPUTER WITH PRINTER • 19 inch LED Screen • latest Generation Intel® Core™ i7 processor or higher version • 8GB Memory, 1TB Hard Drive, cordless key board and mouse, and • Antivirus installed , coral draw Photoshop and related software • With compatible stabilizer

16. Slide Cabinet 1) For keeping 75x25mm slides in vertical position. 2) Capacity 25000 slidses,Can accommodate 300 sledes in each drawer. 3) Lockable door,made of steel with powder coated paint. 4) Drawer should be in slot and completely removable. 17. CCTV Cable 3+1 Pure Copper & Accessories

• CCTV ACCESARIES (POWER SUPPLY12/20AMP /CONNECTOR) • 4 TB HARD DISK(TOSHIBA/WD) • CAMERA CABLE(3+1)PURE COPPER • WITH PIPEING 90MT BUNDLE • MONITOR DELL 18’’ • WALL MOUNT RACK FOR DVR

18. CCTV Camera with DVR and accessories

• CCTV DOME CAMERA (HIKVISION/CP PLUS/DAWAH) COLOUR NIGHT VISION)

• BULLET CAMERA HD COLOUR NIGHT • VISION WEATHERPROOF (MAKE SAME AS ABOVE) • CCTV DVR (16, 32 CHANNEL) (HIKVISION/CP PLUS/DAWAH) • CAMERA CABLE(3+1)PURE COPPER WITH PIPEING 90MT BUNDLE

19.Transparent study models of pediatric dentistry 1. Developmental study models for patient and student education 2. Transparent models demonstrating primary mixed and permanent dentition in correct

eruption pattern 3. Primary dentition models – 6 month to 3 years 4. Mixed dentition models -6-12 years 5. Permanent dentition models - 12-18 years 6. Models of all class and type of malocclusion in a set Transparent models demonstrates caries progression fractured tooth , pulp and periapical pathology 20. Injectable Thermoplasticized Gutta Percha System B

• One-touch controls for downpack, backfill and hot pulp testing • Each function has preset temperature and duration

Page 10: Equipment DPDC 2019-20 - e Tenders€¦ · Easy to read display screen No- Zero adjustment Long file holder Foot control LCD display – Bright and clear display Multi frequency impedance

• Tip temperature is continuously maintained and displayed • Time-out feature prevents overheating • Automatic shut-off precludes using wrong or worn-out tip • Plugger heats instantly for immediate use

Extruder

• Motorized handpiece eliminates hand fatigue and precludes voids • Pencil-grip handpiece enhances control and fits standard handpiece holders • Precise temperature control for consistency • Extra-long prebent needles offer convenience and unprecedented visibility • Heats quickly and shuts off automatically • Handpiece shows remaining material

Handpieces

• Plugger and extruder handpieces are lightweight, strong and durable • Insulation technology keeps handpieces cool. Aluminum shields minimize downtime use

one while autoclaving the other • Buchanan Hand Plugger 0, 1, 2 • Buchanan Heat pluggers • 6 boxes of gutta percha pellets and • 10 – 23 gauge needles • 10- 25 guage needles •

21. HYDROGEN SOLDERING UNIT

• Should have low & high gas formation button • Should show gas pressure from 0 to 500 on a meter • Flame should be fine and sharp • Indicator to show methanol level • Should have gas on button • Water release button • Shoulg have stand to keep nosal • With 100 nosal tips

Two liter extra methanol for refilling

22. FRONT LOADING AUTOCLAVE • Temperature 1210C-15-20 minutes • 1340C-3 minutes • Computer controlled temperature cycle i.e. should have fast and slow 10terilizing cycles. • Chamber volume should be at least 23 litres. • High speed B class autoclave. • Fast cycles with powerful built in steam generator. • Should have 3/6 L type stainless steel chambers and door with electro polish finish • Should have audible and visible indicator for used water to be removed. • Should have audible and visible indicator for water to be used.

Page 11: Equipment DPDC 2019-20 - e Tenders€¦ · Easy to read display screen No- Zero adjustment Long file holder Foot control LCD display – Bright and clear display Multi frequency impedance

• Should have facility of enhanced monitoring and documentation. • Should have independent temperature and pressure monitoring • Should have user friendly intuitive display. • Should have controlled lock out switches to prevent start of cycle when door is not

locked properly. • Should have automatic safety shut off to prevent overheating. • Should have door failure protection system to prevent door from opening at high

pressure. • Should have double lock safety device. • Should have 0.2 micrometer HEPA air filter to provide sterile bacteria free air for drying. • Should have at least 3 preset sterilization cycle • Should have integrated printer for cycle documentation. • Display should be user friendly • Should have sufficient water detector with automatic shut off. • Should be supplied with rust free stainless steel tray. • Should have independent pressure gauge that reads the chamber pressure independently

of the control system for improved monitoring. Should have independent steam generator to provide readily available steam for faster cycles

23. PLASTER DISPENSER DIGITAL • Store 30 kg of plaster powder • Body of Stainless steel • Automatic & stable dispensing • Buckets resistance to moisture • Wall mounted style • Time setting button in second & minutes On off button

24. Orthodontics Malocclusion Classification Model set (Set of Ten) • Made up of transparent acrylic. • Should have proper intercuspation • Should have all Class and type of malocclusion in a set • One model should be of mixed dentition. • One model with metal straight wire fixed appliance bonded on it. • One model with ceramic appliance bonded on it. • One model with lingual appliance bonded on it.

25. Physiodispensor with handpiece LED ,Approx 3200 LUX,Three levels of brightness controlCallibration function,20:180Ncm torque.Surgery motor INTRA LUX S600 LED ,. Multifunction foot control (Cable length 2.5 m),. Motor power for S 600 LED(Speed range 0-40,0000 Input rpm max torque 5.5Ncm. Motor and instrument holder.Bottle holder. Integrated peristaltic pump and power supply.Inputvoltage : 100V-240 V AC.Frequency : 50/60 Hz.Pump flow rate: 0-110ml/min

Page 12: Equipment DPDC 2019-20 - e Tenders€¦ · Easy to read display screen No- Zero adjustment Long file holder Foot control LCD display – Bright and clear display Multi frequency impedance

26.Dental Implant Premium Kit Pilot drill, All twist drills, Three step drill shot & Long, Tip drill, Depth probe, TMA hex driver, Narrow platform torque driver short & Long. 27.LCD Projector Benq Model No:- MX611 28. Cash Counting Machine

Should have highly advanced fake note deterring system

Should be light weight and compact design

It should count coins

Should have LED display Screen and indicator alarms for double notes, Chained notes, Jammed bank notes , half note and counter feit note

Should have Mixed denomination value counting for 2000, and 500 and 50, and 200 and 10

Should have Sorting Facility

Should have Intelligent battering facility

Should have Should have automatic start stop and reset function

Should have Counting speed 1000 note per minute

Should have micro touch control panel

Should have automatic , ultraviolet and magnetic detection.

29.Blood Cell Counter 1) Fully automated 3 part differential cell counter. 2)The instrument should have inbuilt thermal paper printer and attachable to external printer. 3) Should have inbuilt keyboard and attachable to external keyboard. 4) There should be automatic cleaning so that contamination and carryover can be avoided. 5) Data storage capacity of instrument not less than 10,000 samples . 6) Weight of instrument should be low to make it asy to transport. 7) Through put of the instrument should not be less than 30 samples. 8) External power saver (UPS) supplied. 9) To perform various procedure ,Instrument should be user friendly. 10) Large coloured LCD display with touch screen.

Page 13: Equipment DPDC 2019-20 - e Tenders€¦ · Easy to read display screen No- Zero adjustment Long file holder Foot control LCD display – Bright and clear display Multi frequency impedance

11) Online reagent level monitoring and alarm. 12) Flagging of abnormal cell distribution. 13) Twenty parameters with 3-histograms. 30.Dental Compressor • Should be oil free, • should ne noise less , • 1 Hp and above • Pressure range 6-7-8 bars. • Noise level 68 at 5 bars. • Air pure compressor . • should have double head, • Tank capacity 35 liter and above. • 31. Implant Removal Kit

• It should have effective instrumentation for atraumatic removal of failed implants. • It should eliminates the use of trephine drills so as to minimizes bone trauma.

• It should be compatible with all/most implant systems. • Fixture remover kit should includes four diameters: ø3.5, ø4, ø5, ø6 with two lengths:

15mm, 20mm. • Hex driver kit should includes three lengths: 7mm, 12mm, 17mm.

• Fixture remover screws kit should includes six diameters (2 of each): M1.4, M1.6, M1.8, No 1-72unf, M2.0, M2.5.

• Torque indicating ratchet wrench kit should includes one torque wrench. .

32. Digital Acrylizer

Double walled, Outside & inside body made of Stainless steel 304 Grade. The gap between the walls is filled with glass wool to minimize loss of temperature.

Temp. is controlled With digital Display and controller cum digital timer. when the time will complete alarm will be operational with Top quality drain valve is provided for waste removal & cleaning. To work on 220/230 volts Ac. Inner Size 300 x 250 x 350 mm

With digital Display and controller cum digital timer when the time will complete alarm will be operational with inside made of stainless steel 304 Grade. 33.Wet Model trimmer with diamond disk

1. SINGE MOTOR 1 H.P 2800 RPM 2. HEAVY DUTY EQUIPPED WITH TWO BALL BEARING 3. SINGLE SPEED ,CONTINUOUS RATING 4. ONE 10” DIA. DIAMOND DISK FINE 5. IT SHOULD HAVE PROVISION FOR BOTH WET & DRY RUNNING

Page 14: Equipment DPDC 2019-20 - e Tenders€¦ · Easy to read display screen No- Zero adjustment Long file holder Foot control LCD display – Bright and clear display Multi frequency impedance

34. In-built Ultrasonic Scaler • Based on Piezon technology • Detachable Handpiece can be sterilized at 135°C • Works on 3 different modes : Scaling, Perio & Endo • Frequency tracking automatically, sustained • Works at the best frequency point • With 6 Tips • With 1 wrench, Adaptor and foot switch • Gross Weight : 1.5 Kg • Water control button

Speed control button 35. Specifications for Vita Classical Shade Guide

• Should be classic, self-explanatory, simple, quick, reliable and precise in shade determination and handling.

• It should have modern design which reflects perfect esthetics and clear arrangement. • According to the conventional procedure it should be able to determine all tooth shades

safely and systematically. • System should supported, tooth-colored restorative and prosthetic materials used for the

veneering of metal ceramics, densely-sintered zirconia and alumina, as well as indirect laboratory composites, denture teeth and direct micro-hybrid composites.

• System should be provided in proper break proof case.

36. Metal Finishing Kit

• 10 shapes for a complete polishing system

• Brownie points for pre-polishing

• Greenie points for polishing

• Supergreenie points for super-polishing

• Contra-Angle

• BurButler the fully autoclavable bur block that grips all burs

Use Metals Polishing Kit for: amalgams, non-precious and precious alloy

PN 0304BB • Metals Polishing Kit CA 8 Brownie Points (Mini-Pt, Cup, WH6, PC2), 8 Greenie Points (Mini-Pt, Cup, WH6, PC2), 4 Supergreenie Points (Mini-Pt, Cup) 37.Mechanical die saw with 2 extra saws Should have diamond disk Diamond blade should be of size .8mmX.26mm Should have electromagnetic model holder to hold models firmly Should be with a funnel for aspiration and attached suction unit For clear view of the working model, high intensity illumination facility must be provided For safety while working dual control switch must be provided Should be provided with inbuilt stabilizing component

Page 15: Equipment DPDC 2019-20 - e Tenders€¦ · Easy to read display screen No- Zero adjustment Long file holder Foot control LCD display – Bright and clear display Multi frequency impedance

38. Weighing Machine for Dental Materials Technical specifications

Balance model PCE-AB 100 PCE-AB 200

Maximum capacity [max] 100 g 200 g

Readability [d] 0.0001 g (0.1 mg) Verification value [e] 0.001 g (1 mg)

Repeatability 0.00015 g

Linearity ± 0.2 mg

Stabilisation time < 5 s

Tare range Full

Vibration dampening system Function which allows vibration dampening settings

Interface RS-232 bi-directional interface

Software-Kit As an option

Display Graphic display with backlit (multilingual)<br > and capacity tracker

Calibration - Automatic calibration with internal calibration weight (each 2 h or at temperature change)<br >External

calibration with optional weights

Draught shield Supplied as standard (factory fitted)

Draught shield dimensions 175 x 140 x 230 mm

Pan dimensions Diameter 90 mm

Operating Temperature +18 ... +30 °C

Power supply 230V/50 Hz (via 12 V Net adaptor)

Housing Die cast aluminium

Protection IP54

Overall dimensions 235 x 345 x 350 mm

Net weight ca. 6.5 kg

Approvals Legal for Trade Class I scale/CE

Delivery includes

1 x Analytical Balance (Model PCE-AB 100 or PCE-AB 200), 1 x Draught shield, 1 x Net adaptor, User manual (in required language: English, Russian, Italian, French, Spanish, etc.) 39.Suction Machine with motorized suction Vaccum pump :Twin Head , oil free Diaphragm Pump Operating Voltage : 230 Volt A.C. + 5% Jars for Collection : 2x 2 Liters Polycarbonate Shatterproof ( with flat valve) Remote Operation : Foot switch provided to unit selectively