EPA-NE - Data Validation Worksheet · SOMOl .2 Water ~ Affected Analytes Action Water Soil Affected...

35
EPA-NE - Data Validation Worksheet Case: _______ SDG:. _ _________ VOA/SY/Pest/PCB COMPLETE SDG FILE (CSF) AUDIT Organic Fractions: - - ------- - -- ---- Missing Jnformation Date Lab Contacted Date Received Validator: ________ Date: _ ____ 1/13

Transcript of EPA-NE - Data Validation Worksheet · SOMOl .2 Water ~ Affected Analytes Action Water Soil Affected...

EPA-NE - Data Validation Worksheet

Case: _______ SDG:._ _________

VOA/SY/Pest/PCB

COMPLETE SDG FILE (CSF) AUDIT

Organic Fractions: - - -------- ----- ­

Missing Jnformation Date Lab Contacted Date Received

Validator: ________ Date: _ ____

1/13

EPA-NE - Data Validation VOA/SV /Pest/PCB-I

Case: _ ________ _ SDG: _ _ _ ___ _ _

Company: _ _ _ _ ___ _ _ Contacted: Yes No Date:-- --- ----­Sampler:------- ­

I. PRES ER VATION AND HOLDING TIMES - Circle sample numbers with exceeded technical holding times or omitted preservation. List all required preservation codes and circle omitted preservation codes. Circle all exceeded technical holding times. Identify extraction technique after"# ofDays"/(*Extraction Code).

VOA BNA PEST/PCB

Sample No. (TR No.)

Matrix Pres. Code

Date Sampled

Date Analyzed

# of Days from

Sampling to

Analysis

Action Date

Extracted

# of Days from

Sampling to Extr./(•)

Date Analyzed

# of Days from

Sampling to Anal.

Action Date

Extracted

fl ofDays from

Sampling to

Extri.(• )

Date Analyzed

# of Days from

Sampling to Anal.

Action

Preservation Code: (*Extraction Code:) Action Code: LIL - Liquid/Liquid J - Estimate (J) Detected Values I. Cool @ 4°C (± 2°)

2. Preserve with HCI to at least pH 2 SON - Sonication UJ - Estimate (UJ) Non-Detected Values SEP - Separatory Funnel R - Reject (R) Non-Detected Values 3. Protect from light

4. Freeze SOX - Soxhlet 5. Room Temperature (Avoid excessive heat) SPE • Solid Phase Extraction

Date: Validator: - - - - - - -------­

1/13

--- - - --- - --- - -- --- - ---

EPA-NE - Data Validation Worksheet

Case: SDG:________ _ _

VOA/SV-II-A II A. GC/MS INSTRUMENT PERFORMANCE CHECK - (TUNING) Note: NOT for Selected Ion Monitoring (SIM) Analysis

formance Checks that are outside method QC · · ·-· - --- ---,

VOA Instrument Performance Check (Compound Name)

Analysis Date and

T ime

Instrument Ions Affected

Percent Relative

Abundance

QC Limits Samples Affected Action

Comments:

SV Instrument Performance Check (Compound Name)

Analysis Date and

Time

Instrument Ions Affected

Percent Relative

Abundance

QC Limits Samples Affected Action

Comments:

If tuning compounds and criteria are different from those specified in CLP SOW SOMO 1.2, the validator should include a copy of the method-specific tuning criteria with this worksheet.

Validator: Date:

1/13

- -----

EPA-NE - Data Validation Worksheet

Case: SDG:_ _ ________ VOA/SV-11-B II B. GC/MS INSTRUMENT PERFORMANCE CHECK - 12-hour clock

.b .List all I Perf< Ch di d h db d the 12-h..., ....... .-1,..1 ...... . - .......... -.

Fraction Tune Standard Injection Time

(VOA orSV) or CCV ID Date and Time Elapsed Samples Affected Action (hours)

Validator:_ _ _____ _ _____ _ Date:­1/13

EPA-NE - Data Validation Worksheet

Case: SDG: _ _ ___ ___ _

Pest/PCB-II-A I .'dII A. GC/ECD INSTRUMENT PERFORMANCE CHECK List all h -- ----- -- - -- -- -­

RCM (Section II) Dateffime Instr. Column Compound % Resolution Samples Affected Action

I PEM (Section II and IV) I I I I I I I I

I1NDA & B (Section Ill) I . I I I I I I I

I INDA & B (Section IV) I I I I I I I I

Date: _______Validator: _ ___ _ ___ ___ ___

1/13

--- ---------- -- ------ -

EPA-NE - Data Validation Worksheet

Case: SDG:_____ ___ _ _

Pest/PCB-11-B II B. GC/ECD INSTRUMENT PERFORMANCE CHECK - Retention Times - List all analvtes that exceed retention time criteria

PEM (Section II and IV) Dateffime Instr. Column Compound RT Window RT Samples Affected Action

I INDA & B (Section IV) I I I I I I I I I

Validator: Date:

1/13

- ----- -------- ---- ---

EPA NE - Data Validation Worksheet

Case: SDG:_ _ ___ ______

Pest/PCB-11-C II C. GC/ECD INSTRUMENT PERFORMANCE CHECK - Accuracy Check of Initial Calibration

List all analytes that are outside the %0 criteria ·

PEM Sample ID Date/Time Instr. Column Comoound %0 Samples Affected Action

Date:Validator:~

1/13

- --

EPA-NE - Data Validation Worksheet

Case:______ _ _ SDG:______ ___ Pest/PCB-11-D

d ,• -II D. GC/ECD 0 -- ---- -- - ----- -- - _.'"" -- --- --- ... --- - - ­------. _

PEM (Section lI) Date/Time Instr. Column DDT, % DOD, DOE, Endrin Samples Affected Action Endrin, or Breakdown ketone, Endrin Combined a ldehvde Present

IPEM (Section IV) I I I I I I I I I

Validator: _ _ _____ ________ Date:---­

1/13

EPA-NE - Data Validation Worksheet

Case:________ SDG:_ ________ Pest/PCB-III

INDA/INDB, RecalculatedINDC, Date Instrument Column Analytes

or Multicomponent RT Window

IA. % RSD Linearit~

IB. Retention T ime Windows

·%RS0 Samples Affected Action

I

I

Did the laboratory follow the correct analytical sequence? y N

Did the laboratory analyze the initial calibration at the appropriate concentration levels? y N

Validator:_ _ _ ____ _ _ Date: ----­ -­

1/13

- - ----- - - - - - ----

Date of ICAL Instrument Fraction Matrix Compound %RSD RRF* Samples Affected Action (Detect/ND)

Comments:

EPA-NE - Data Validation Worksheet

Case: SDG:___ _ ______

VOA/SV-III III. INITIAL CALIBRATION - List all analytes that are outside calibration criteria.

. RRF and average RRF

Did the laboratory follow the correct 12-hour clock analytical sequence? Ifno, fill out Worksheet VOA/SY-II B. YN

Did the laboratory analyze the initial calibration at the appropriate levels? YN

Validator: Date:

1/13

---- ---

EPA-NE - Data Validation Worksheet

Case:________ _ SDG: _ _ _ _ _____

Pest/PCB-IV-A IV A. CALIBRATION VERIFICATION - Accuracy Check (%D) - List all analytes that are outside calibration criteria

Standard ID Date Time Instrument Column Analyte %0 Samples Affected Action

<Detect/ND)

'

Validator: _ _ _ _____ _____ _ Date:

1/13

- - --- -

EPA-NE - Data Validation Worksheet

Case: SDG:_ _ _ _ _ _ _ ___

Pest/PCB-IV-B IV B. CALIBRATION VERIFICATION -Time Elapsed - List all non-compliant standards.

Fraction Instrument Instrument Injection Time Action

(PEST or and Column Blank or Date and Time Elapsed Samples Affected (Detect/ND)

PCB) ID Sample ID (hours)

Validator: _ _ _ _ _ _ ___ _ ____ _ Date: ­

1/13

IV

EPA-NE - Data Validation Worksheet

Case:____ ___ _ SDG:___ _____ _

VOA/SV-IV ~~£...JA.oJ .. _ ...... - ... ...- ...J ..._...., ........._ .. _ .... _. .._.._,....,...,__ ------ ---- - - - -· '-"'-' 1. "1.&.&.J. "IVA l "l'-,.S '-'L&&.J.L...... ..&.'-4•0 & A '-' .I. '

Fraction (VOA/SV) Instrument

Date of

ICAL

Date &

Time of

CCAL

Matrix Compound %0 RRF Samples Affected Action

(Detect/ND)

Comments:

Did the laboratory follow the co1Tect 12-hour clock analytical sequence? Ifno, fill out Worksheet VOA/SY-II B. YN

Validator: _ _ _____ _ _ Date:

1/13

EPA-NE - Data Validation Worksheet

Case:____ ____

VOA/SV /Pest/PCB-V-A V. A. BLANK ANALYSIS

SDG:___ ___ ___

List the blank contamination below. Concentration Level: __

Sampler: _______ Company: Contacted: Yes No Date:____

1. Laboratory: Method, Storage and Instrument Blanks

Fraction/ Same'e ID Date Date lnstru ment/ Matrix (Blan Type) Extracted Analvzed Column Compound Cone. (units)

2. Field: Equipment (Rinsate), Trip and Bottle Blanks

Fraction/ Same'e ID Date Date Instrument/ Compound Cone. (units) Matrix (Blan Type) Extracted Analvzed Column

Date:Validator: ~-~~~~~-~~~~~~~~~~~-

1/13

EPA-NE - Data Validation Worksheet

SDG:________ _Case:~--------~ VOA/SV /Pest/PCB-V-B V. B. BLANK ACTIONS - List the maximum concentrations of blank compounds.

Compound TJpe of lank

Date Blank Sampled,

Originated, or Analvzed

Max. Cone. (unit)

Blank CRQL (unit)

Blank 2xCRQL1

(unit)

Blank 5xCRQL2

(unit)

Samples Affected

Action

For methylene chloride, 2-butanone, an :l acetone only. 2 For bis(2-ethylhexyl)phthalate only.

Comments: --------------------------------------------~

Date: ______Validator:------------­

1/13

EPA-NE- Data Validation Worksheet

Case: SDG:________

SV-Vl-A VI A. DEUTERA TED MONITORING COMPOUNDs (DMCs) - List all DMC recoveries that are outside the control limits. Page l of2

Method

SOMOl.2

Other:

Sample ID Matrix

Phenol-d5 BCE Water Soil Water Soil

39-106 17-103 40-1 05 12-98

% Recovery % Recovery

2CP Water Soil

41-106 13-101

% Recovery

Semi-Volatile Method QC Acceptance Criteria

4MP NBZ Water Soil Water SQ!! 25-111 8-100 43-108 16-103

% Recovery % Recovery

2NP DCP Water Soil Water Soil 40-108 16-1 04 37-105 23-104

% Recovery % Recovery

4CA Water Soil 1-145 1-145

% Recovery

Validator:

BCE= Bis(2-chloroethyl)ether-d8

NBZ= Nitroben zene-d5

4CA= 4-Chloroaniline-d~

2CP= 2-Chlorophenol-dJ 2NP= 2-Nitrophenol-dJ

4MP= 4-Methyhlphcnol-d8

DCP= 2A-Dichlorophenol-d3

Date:

1/13

EPA-NE - Data Validation Worksheet

Case: SDG:_________

SV-Vl-A (Cont'd) VI A. DEUTERATED MONITORL~G COMPOUNDs (DMCs)- List all DMC recoveries that are outside the control limits. Page 2 of2

Method Semi-Volatile Method QC Acceotance Criteria

DMP ACY 4NP FLR NMP

SOMOl.2 Water Soil Water Soil Water Soil Water Soil Water Soil 43­ 40­

47-114 111 41-107 20-97 33-116 16-166 42-111 108 22-104 1-121

Other:

Sample ID Matrix % Recovery % Recovery %Reco\'ery % Recovery % Recovery

ANC PYR

Water Soil Water Soil

44- 11 0 22-98 52-119 51-120

% Recovery % Recovery

BAP Water Soil

43­32-121 111

% Recovery

DMP=Dimethylphthalate-d6 ACY=Acenaphthylene-d8

FLR=Fluorene-d10 NMP=4.6-Dinitro-2-methylphenol-d: PYR=Pyrene-d 10 BAP=Benzo(a)pyene-d 12

Note: Refer to NFG for guidance on actions· required for failures in DMC recoveries.

Validator: - - - --- - - ----- - - --- - ­

4NP=4-Nitrophenol-d4 ANC=Anthracene-d 10

Date:---------­

1/13

EPA-NE - Data Validation Worksheet

Case: SDG: ~~~~~~~~-

S V -VJ-B VJ B. DEUTERATED MONITORING COMPOUNDs (DMCs) for SIM - List all DMC recoveries that are outside the control limits.

Semi-Volatile Organics b,· Selected Ion Monitorinl? Analvsis Acceptable QC Criteria

Method: Fluoranthene-d 10 2-Methylnaphthalene-d10

SOMOl .2 Water ~ Affected Analytes Action Water Soil Affected Analytes Action

50-1 50 50-150 (Detection/ND) 50-150 50-150 (Detection/ND)

Sample ID Matrix % Recovery % Recovery

Fluoranthenc Naphthalene

Pyrenc 2-Methylnaphthalene Be1120(a)anthracene Acenaphthylene Chrysene Acenaphthene

Benzo(b )fluoranthcne Fluorene Benzo(k)lluoranthcne Pentachlorophenol Benzo(a)pyrene Phenanthrenc Indeno( I .2.2-cd)pyrene Anthracene Dibenzo(a.h)anthracene Benzo(g.h.i)perylene

Note: Refer to NFG for guidance on actions required for failures in OMC recoveries.

Validator: --- ----------- - - - - - - Date:---------­

1/13

EPA-NE - Data Validation Worksheet

Case: SDG: ~~~~~~~~

VOA-VI VI. DEUTERATED MONITORING COMPOUNDs (DMCs) - List all DMC recoveries that are outside the control limits. Page l of2

NOTE: The same control limits are applied to the selected ion monitoring (SIM) analysis.

Method Volatile Method QC Acceptance Criteria

SOMOl .2

Other:

Vinyl chloride-d3

Water Soil 65-131 68-122

Chloroethane-d~ \Vater .s_QjJ

71-131 61-130

DCE Water Soil 55-1 04 45-132

2-Butanone-d~ Water Soil 49-155 20-182

Chloroform-d \\later Soil 78-121 72-123

DCA Water .s_QjJ

78-129 79-122

Benzene-d6

Water Soil 77-124 80-121

Samole ID Matrix % Recoverv % Recovery % Recovery % Recoverv % Recoverv % Recovery % Recoverv

DCE= 1.1 -Dichloroethene - d2 DCA= I .2-Dichloroethane-d4

Validator: ------ ----------- Date: ---- - - ­

1/13

EPA-NE- Data Validation Worksheet

Case: SDG: ~~~~~~~~-

VOA -VI (Cont'd) VI. DEUTERATED MONITORING COMPOUNDs (DMCs)- List all DMC recoveries that are outside the control limits. Page 2 of2 NOTE: T he same control limits are applied to the selected ion monitoring (SIM) analysis .

.\ilethod Volatile Method QC Acccptance Criteria

SOMOl.2 DPA

Water Soil

79-124 74-124

Tolucne-d8

Water Soil 77-1 21 78-121

TOP Water Soil 73-1 21 72-130

2-Hexanone-d~ Water Soil

28-135 17-18•1

I .4-Dioxanc-d8

Water SQil 50-150 50-150

TCA Water ~ 73-125 56-161

DCZ \.Vater Soil 80-131 70-13 1

Other:

Sample ID Matrix % Recoverv % Recover.1 % Recoverv %Recovery % Recoverv % Recovery %Recoverv

DPA= 1.2-Dichloropropane -d6

TCA= 1.1.2.2-Tetracholoroethane-d: Note: Refer to '.'IFG for guidance on actions required for failures in DMC recoveries.

Validator: - ---------------­

TOP= trans-1.3-0ichloropropene-d, DCZ= 1,2-Dichlorobenzene-d4

Date:----- --­

1/13

EPA-NE - Data Validation Worksheet

Case: SDG:._ _ ________

Pest/PCB-VI VI. SURROGATE COMPOUNDS: Spike Recoveries and Retention Time Shift

i.J l !Sl <111 :SUI IU}!,'1lC cllldIYl.C:> lll(ll, Q,l ~ V\.11...,lU\,, lll\o,; l-'"'' '"'"'"" I "VV,.. "'· V u.u- • ,.., .......... u.,V'H ........ _ _. .. ·~-- ·-·

I % Recovery QC Limits II Retention Time Windows I Method Column I Column 2 Column I Column 2

TCX DCB TCX DCB TCX DCB TCX DCB

SOMOl.2 30-150 30-150 30-150 30-150

Other:

Sample ;<; umber/Matri x Date/Time % Recovery Retention Time Shift Action

Note: Refer to NFG for guidance on actions required for failures in surrogate recoveries.

Date:Validator:--- ------­- --- - - --- - ~ 1/13

--- ---- --- ----- --- - -----

EPA-NE- Data Validation Worksheet

Case: SDG: _ _ _ _ ____ ___

Pest/PCB-VII-C VII C. PESTICIDE/PCB CLEANUP - Sulfur Cleanup

Sample chromatograms were reviewed and found to be free from interfering sulfur peaks. y N

Ifno, list the compounds and samples affected by the unacceptable sulfur cleanup.

Sulfur Interference ActionSamples Affected (Major/Minor/Limited)

Were all target compounds less than QL for the Sulfur blank? y N

Action: Refer to EPA New England Data Review Program Supplement guidance (Section 2.11) for actions to be taken for deficient sulfur cleanup. Comment on any action taken below.

Validator: Date:

1/13

-------

EPA-NE - Data Validation Worksheet

Case: SDG:__________

Pest/PCB-VII-A VII A. PESTICIDE/PCB CLEANUP - GPC Calibration and Verification

The GPC Calibration data and GPC Calibration Verification Solution recovery data were reviewed and found to meet criteria. Y N NA

If no, list the compounds and samples affected by the unacceptable GPC performance.

GPC% Date/Time of GPC GC Resolution Action Samples Affected % Rec QC LimitsAnalysis Analyte Calibrat ion or or RT

Date Calib. Verification Shift

y NWere all target compounds less than QL for the GPC blank9

Were acceptable GPC Calibration Verifications performed at the correct frequency? y N

Were Aroclor patterns similar to those corresponding Aroclor standards of the Initial Calibration sequence? y N

Action: Refer to National Functional Guidelines for the appropriate action to be taken. Comment on any action taken below:

Validator: _ _ _ ___ ___ ___ ___ _ _ Date:

1/13

--- - ---

EPA-NE - Data Validation Worksheet

Case: SDG:____ _ _ _ ____

VOA/SV-VII VII. SEMIVOLATILE CLEANUP - GPC Calibration and Verification-List all analytes that are outside method cleanup QC criteria.

Date/Time GPC

Type of Cleanup Instrument# Calibrated or

or Lot# C heck Solution Analyzed

Compound % Rec QC Limits Samples Affected Action

y NDid the GPC column meet: resolution requirements? y NPeak shape requirements? y NRetention time shift requirements? y NWas the GPC calibration, Silica Gel cleanup checked at the method required frequency with correct compounds and concentrations? y NWere all compounds less than QL for the GPC/Si lica Gel/Acid-Pa11ition blank?

y NDid the blank surrogate recoveries and IS area counts and RTs (if added) meet method QC acceptance criteria? Comments:

Validator:_ _ _ ______ ___ ___ _ Date:

1/13

EPA-NE - Data Validation Worksheet

Case: SDG:~ ~~------~ Pest/PCB-VII-B VII B. PESTICIDE/PCB CLEANUP - Florisil Cartridge Performance Check

The Florisil Cartridge Performance Check recovery data were reviewed and found to meet criteria. y N

Ifno, list the analytes and samples affected by the unacceptable Florisil Cartridge Check.

Florisil Car tridge

Lot#

Date of Florisil Cartridge

C heck

GC Analysis

Date Analyte

% Rec.

QC Lim its Samples Affected Action

Were acceptable Florisil Cartridge Performance Checks performed at the coJTect frequency" y N

Action: Refer to Functional Guidelines for the appropriate action to be taken. Comment on any action taken below:

Validator: Date: -­~~~~~~--~~~~~~~~~ --~ -­

1/13

-- ----

EPA-NE - Data Validation Worksheet

Case: SOG:__________

VOA/SV /Pest/PCB-VIII VIII. MATRIX SPIKE/MATRIX SPIKE DUPLICATE - List all MS/MSD analytes that are outside method QC acceptance

criteria. Use a separate worksheet for each MS/MSD pair.

Sample# _ _ ___ _ _ Matrix ________ Concentration Level ------- ­

Fraction Compound

Column 1 Column z* Method QC Limits

ActionMS O/o

Rec.

MSD O/o RPO

Rec.

MS MSD O/o % RPD

Rec. Rec.

O/o

Recovery RPO

For Pest/PCB only.

Date: ---Validator:----- -----­

1/13

EPA-NE - Data Validation Worksheet

Case: SDG:_ ___ _____ _

VOA/SV /Pest/PCB-IX IX. FIELD DUPLICATE PRECISION - List all field duplicate analytes that are outside criteria.

Use a separate worksheet for each field duplicate pair.

Sample Number ______ Duplicate Sample Number ______ Matrix ---- ­

Sample Sample QL

Duplicate . Duplicate QL

Fraction Compound RPO Cone. SQL 2xSQL

Cone. SQL 2xSQL

QC Acceptance Criteria RPO or Action

NA•

·For instances where one duplicate result is ND (or reported less than the sample QL).

Does the MS/MSD data indicate acceptable laboratory precision? Y N

Refer to EPA New England Data Review Program Supplemental guidance for field duplicate actions (Section 2.8). Comments:

Sampler Name: ______ Contractor Name: ------ Date Contacted: _________

Reason for Contact and resolution obtained: ----------~-------------- ­Validator:------------ Date:------------- ­

1/13

EPA-NE - Data Validation Worksheet

Case: SDG:._ _ _ _ _ ___ _ _

VOA/SV/Pest/PCB-X-A X A. ACCURACY CHECK (Performance Evaluation Results) - List all analytes that are outside criteria.

y NAre more than one-half of the PES analytes within criteria for each parameter?

Non-EPARegion I Type ofAmpulePE Sample ActionSamples Affected PESEPA PESCone.AnalyteMatrix Fraction PESNumberNumber Scores""Scores*

* For Region I PESs indicate the Region I PES Score Report Result: Action High; Action Low; TCL MISS; TCL CONT AMIN ANT; TIC HIT; TIC MISS; TIC CONTAMINANT

** For Non-EPA PESs indicate the non-EPA PES Score: PES COMPOUND MISS; PES COMPOlJND CONTAMINANT; PES COMPOl.JND HIT (% Recovery Limits)

Refer to EPA New England Data Review Program Supplemental guidance for EPA PES and actions (Section 2.7).

Date: ----Validator:-------------- ---~

1/13

EPA-NE - Data Validation Worksheet

Case: SDG:___ _ _ _ _ _ _ _

VOA/SV /Pest/PCB-X-B X B. ACCURACY CHECK (Laboratory Control Sample [LCS] Results) - List all analytes that are outside criteria.

Column 2Acceptable Column 1 ActionSamples Affected CompoundFractionMatrix MethodLCS ID LCS%R%R Rani'e LCS%R

Date:Validator:--------------- --- - - --- ­

1/13

EPA-NE - Data Validation Worksheet

Case: SDG:_________ _ VOA/SV-XI XI. INTERNAL STANDARD PERFORMANCE List the internal standards that are outside the area count and retention time method QC acceptance criteria. IS Area Count Method QC acceptance criteria: - --- ---- --- - - --­IS Retention Time Method QC acceptance criteria: - - ----- --- --- - ­

Sample Date and Non-Compliant Acceptable Range (ISRTInternal Action FractionInstrumentNumber Time Internal area or RT shift)ShiftStandard AreaAnalyzed(TRs) Standard

Date:Validator:----- - - - ---- --- - - --------­

1/13

------ --

EPA NE - Data Validation Worksheet

SDG:_ _ _ _ _____Case:_____ ___ _

Pest/PCB-XII XII. ANALYTE IDENTIFICATION List samples below that contained false positive and/or negative reported results, and samples that contained detected compounds which have a percent difference greater than ±25% between the two columns.

Column I ID: Column 2 ID: Sample ID Analyte

RT RT Window Cone. RT RT Window Cone. %0 Action

y NWas OC/MS Confirmation performed for the appropriate samples?

y NWere corresponding Aroclor standards analyzed within 72 hours of the sample(s) with Aroclors detected?

Validator: _ ___ _ ___ _ _ _ _ _ Date:

1/13

---- --

EPA-NE- Data Validation Worksheet

Case: SDG:__________ VOA/SV-XII XII. TARGET COMPOUND IDENTIFICATION - List the analytes that are outside the acceptance criteria.

Sample Number Compound MS Ions RRT Action

Validator:______________ Date:­

1/3

--------- --- - - - --

EPA-NE - Data Validation Worksheet

Case: SDG:________ _

VOA/SV-XIII XIII. SAMPLE QUANTITATION AND% SOLIDS

Recalculate, from the raw data, the concentrations for one positive detect and one reported sample quantitation limit for a non-detect in a diluted sample or soil sample per fraction. (Note: Although NFG requires that one calculation for each fraction in each sample be performed, the validator is only required to reproduce an example, for each fraction, of one positive detect and one sample quantitation limit calculation on this worksheet.)

Do all soil/sediment samples have% solids greater than 30%? y N lfno, list sample numbers,____________ _ _____________ _ ______ Refer to EPA New England Data Review Supplemental Program guidance for actions related to %solids (Section 2, 10).

Fraction Calculation

VOA

Sample No.:

Reported Compound:

Reported Value:

Not Detected Compound:

Reported Quantitation Limit:

BNA

Sample No.:

Reported Compound:

Reported Value:

Not Detected Compound:

Reported Quantitation Limit:

Validator: Date:

1/13

EPA-NE- Data Validation Worksheet

Case: SDG: _ _ _ _ ___ _ _

Pest/PCB-XIII XIll. SAMPLE QUANTITATION AND %SOLIDS

Recalculate, from the raw data, the concentrations for one positive detect and one reported sample quantitation limit for a non-detect in a diluted sample or soil sample per fraction. (Note: Although NFG requires that one calculation for each fraction in each sample be performed, the validator is only required to reproduce an example, for each fraction. of one positive detect and one sample quantitation limit calculation on this worksheet.)

Y N Do all soil/sediment samples have % solids greater than 30%? If no, list sample numbers....,....=---- ---- - - ------,-,-- --c,---.,--- -,--.,---,-,- :-,-:---,-,,---,--,,.--:-":'." Refer to EPA New England Data Review Supplemental Program guidance for actions related to %solids (Section 2.10).

Fraction Calculation

Pesticides

Sample No.:

Repo11ed Compound:

Reported Value:

Not Detected Compound:

Reported Quantitation Limit:

PCB

Sample J\io.:

Repotted Compound:

Reported Value:

Not Detected Compound:

Reported Quantitation Limit:

Date: ~~~~~~~~-Validator:

~~~~~~~~~~~~~~~-

1/13

- - - ---

EPA-NE - Data Validation Worksheet

Case: SDG:_________ _ VOA/SV-XIV XIV. TENTATIVELY IDENTIFIED COMPOUNDS (TICs)

List the 5 TICs having the highest concentration for each sample parameter.

Sample Number Fraction Compound RRT Est. Cone. Action

Validator:____ _____ Date:

1/13