Environmental Products Selectrion Guide...• Perfect for light duty welding applications •...

2
CUSTOMER ASSISTANCE POLICY The business of The Lincoln Electric Company ® is manufacturing and selling high quality welding equipment, consumables, and cutting equipment. Our challenge is to meet the needs of our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln Electric for information or advice about their use of our products. Our employees respond to inquiries to the best of their ability based on information provided to them by the customers and the knowledge they may have concerning the application. Our employees, however, are not in a position to verify the information provided or to evaluate the engineering requirements for the particular weldment. Accordingly, Lincoln Electric does not warrant or guarantee or assume any liability with respect to such information or advice. Moreover, the provision of such information or advice does not create, expand, or alter any warranty on our products. Any express or implied warranty that might arise from the information or advice, including any implied warranty of merchantability or any warranty of fitness for any customers’ particular purpose is specifically disclaimed. Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control of, and remains the sole responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in applying these types of fabrication methods and service requirements. Subject to Change – This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.com for any updated information. All trademarks and registered trademarks are the property of their respective owners The operation of welding fume control equipment is affected by various factors including proper use and positioning of the equipment, maintenance of the equipment and the specific welding procedure and application involved. Worker exposure level should be checked upon installation and periodically thereafter to be certain it is within applicable OSHA PEL and ACGIH TLV limits. Publication MC19-17 | Issue Date 05/19 © Lincoln Global, Inc. All Rights Reserved. www.lincolnelectric.com/automation Lincoln Electric Company 22221 St. Clair Avenue Cleveland, OH 44117 U.S.A. Replacement Filters Visit us at weldfumefilters.com to order your genuine Lincoln Electric replacement filters that have been developed specifically for welding fume. Knowledge Contact Us Contact one of our Highly Trained Environmental Specialists at 1-888-935-3878 Option 4 See the Lincoln Electric E1.10 Catalog or lincolnelectric.com/fumecontrol for product numbers and pricing info. What is Low Vacuum Extraction? Low vacuum is when high volumes of air are being extracted. The typical range of CFM in a low vacuum application is 650-850 CFM. Low Vacuum extraction is traditionally done 6-12” from the weld source. Low vacuum extraction is handled by flexible extraction arms with larger diameter openings. What is Welding Fume? Welding fumes are comprised of complex metallic oxides, often along with silicates and fluoride compounds, forming particles that are typically less than 5 microns (µm) in diameter. What is High Vacuum Extraction? High vacuum is high local pressure where low volumes of air are being extracted. The typical range of CFM in a high vacuum application is 30-180 CFM. High vacuum extraction is traditionally done 2-4” from the fume source and is typically handled by small, compact systems that utilize fume extraction guns and extraction nozzles with small openings. OSHA Requirements The Occupational Safety and Health Administration (OSHA) is the primary US agency regulating air quality. OSHA sets PELs (Permissible Exposure Limits) for compounds, some of which may be found in welding fume. ENVIRONMENTAL PRODUCTS Selection Guide LINCOLN ELECTRIC - MAKING FUME MANAGEMENT EASY of U.S. and foreign content Made in the USA PRISM® - All-in-one vertically oriented filtration system

Transcript of Environmental Products Selectrion Guide...• Perfect for light duty welding applications •...

Page 1: Environmental Products Selectrion Guide...• Perfect for light duty welding applications • Connects to a fume gun or extraction nozzle • SCFM: 55-115 CFM • Unique, manually

C U S TO M E R ASS I S TA N C E P O L I C Y

The business of The Lincoln Electric Company® is manufacturing and selling high quality welding equipment, consumables, and cutting equipment. Our challenge is to meet the needs of our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln Electric for information or advice about their use of our products. Our employees respond to inquiries to the best of their ability based on information provided to them by the customers and the knowledge they may have concerning the application. Our employees, however, are not in a position to verify the information provided or to evaluate the engineering requirements for the particular weldment. Accordingly, Lincoln Electric does not warrant or guarantee or assume any liability with respect to such information or advice. Moreover, the provision of such information or advice does not create, expand, or alter any warranty on our products. Any express or implied warranty that might arise from the information or advice, including any implied warranty of merchantability or any warranty of fitness for any customers’ particular purpose is specifically disclaimed.

Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control of, and remains the sole responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in applying these types of fabrication methods and service requirements.

Subject to Change – This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.com for any updated information.

All trademarks and registered trademarks are the property of their respective owners

The operation of welding fume control equipment is affected by various factors including proper use and positioning of the equipment, maintenance of the equipment and the specific welding procedure and application involved. Worker exposure level should be checked upon installation and periodically thereafter to be certain it is within applicable OSHA PEL and ACGIH TLV limits.

Publication MC19-17 | Issue Date 05/19© Lincoln Global, Inc. All Rights Reserved.www.lincolnelectric.com/automation

Lincoln Electric Company 22221 St. Clair Avenue

Cleveland, OH 44117 U.S.A.

Replacement Filters

Visit us at weldfumefilters.com to order your genuine Lincoln Electric replacement filters that have been developed specifically for welding fume.

Knowledge

Contact UsContact one of our Highly Trained Environmental Specialists at 1-888-935-3878 Option 4See the Lincoln Electric E1.10 Catalog or lincolnelectric.com/fumecontrol for product numbers and pricing info.

What is Low Vacuum Extraction?Low vacuum is when high volumes of air are being

extracted. The typical range of CFM in a low vacuum

application is 650-850 CFM. Low Vacuum extraction

is traditionally done 6-12” from the weld source. Low

vacuum extraction is handled by flexible extraction

arms with larger diameter openings.

What is Welding Fume?Welding fumes are comprised of complex metallic

oxides, often along with silicates and fluoride

compounds, forming particles that are typically less

than 5 microns (µm) in diameter.

What is High Vacuum Extraction?High vacuum is high local pressure where low

volumes of air are being extracted. The typical

range of CFM in a high vacuum application

is 30-180 CFM. High vacuum extraction is

traditionally done 2-4” from the fume source and

is typically handled by small, compact systems

that utilize fume extraction guns and extraction

nozzles with small openings.

OSHA RequirementsThe Occupational Safety and Health Administration

(OSHA) is the primary US agency regulating air

quality. OSHA sets PELs (Permissible Exposure Limits)

for compounds, some of which may be found in

welding fume.

ENVIRONMENTAL PRODUCTS Selection Guide

LINCOLN ELECTRIC - MAKING FUME MANAGEMENT EASY

of U.S. and foreign content

Made in the

USA

PRISM® - All-in-one vertically oriented filtration system

Page 2: Environmental Products Selectrion Guide...• Perfect for light duty welding applications • Connects to a fume gun or extraction nozzle • SCFM: 55-115 CFM • Unique, manually

Extension Crane

Configured to Application

(CTA)

Miniflex®

K4260-2 One-Pak® PackageSee E13.11 for complete specs.

See E13.109 for complete specs. See E13.110 for complete specs.

See E13.16 for complete specs. See MC12.20 for complete specs.

See E13.15 for complete specs.

See E13.14 for complete specs. See E13.53 and E13.50 for complete specs.*Not suitable for grinding Aluminum, Magnesium or other explosive materials.

DownFlex 100-NF

Statiflex 800 Dual Arm Base Unit

DownFlex 200-M

DownFlex 400-MS/A

Statiflex® 200-M & Statiflex 800 (MERV 14 & MERV 16 Filter Configurations)

DownFlex® 100-NF / 200-M / 400-MS/A Downdraft Table

Prism® (4,8, & 12 Bank Filters)

Statiflex Complete 4Prism Compact Statiflex Filter Bank (4-48 Bank Filters)

Circulator® Free-Standing General Filtration System

Lincoln Fire Suppression System

Plug and Play Products

(PNP)

• Lightweight and portable, high vacuum system• Perfect for small shops• Connects to a fume gun or extraction nozzle• SCFM: 95 CFM (Low) or 108 CFM (High)• Current Sensor – Automatic start/stop capability

by sensing welding current

• All-in-one vertically positioned filter bank• Perfect for general/heavy fabrication,

plasma, education, and automation applications• Connect to a modular or formed hood• SCFM: 2750-19400 @ 7 in. WG• Automatic filter cleaning• Quiet operation through

added silencer• MERV 11, 16 and PTFE filter choices• Certified Prism Thermal Suppression system optional•

• All-in-one horizontally positioned filter bank • Perfect for general/heavy fabrication and

automation applications • Competitively priced• SCFM: 2650 @ 6 in. WG• Automatic filter cleaning• MERV 11, 16 and PTFE filter choices• Quiet operation through added silencer

• Reduced height • Crane-less installation • Variable Frequency Drive (VFD) comes standard • Quiet operation • Simple maintenance • Efficient vertical filters • Certified Prism Thermal Suppression system optional

• Horizontally positioned filters• Can be used to extract air thru arms,

hoods or a push pull system• Perfect for general fabrication and

education applications• Customizable for 5 to 100 HP fans• Small to large filter bank configurations• SCFM: 2240-27840• Automatic filter cleaning

• Free-standing general filtration system• Perfect for manufacturing and fabrication facilities that cannot hang

ductwork or have overhead cranes in use• Can also act as a supplement to natural/forced ventilation• Designed for flexibility and easy relocation within a facility• Economical alternative to a push/pull system• SCFM: 6000 CFM• Quiet operation• Automatic filter cleaning

• Stationary wall mounted, low vacuum fume extractors• Customizable and versatile• Perfect for maintenance departments, general and heavy

fabrication applications, weld schools and weld shops• Light to heavy duty fume extraction and filtration• SCFM: 735 CFM with LFA 3.1/4.1 extraction arm(s)

and SF2400 fan • Single or dual arm configurations• Available with automatic filter cleaning or disposable filters

• Compact/fixed fume extraction workstations• Accommodate Stick, TIG, MIG, flux-cored, grinding*

and plasma cutting processes• SCFM: 1750 CFM• Available with automatic filter cleaning, disposable

filters or configured for connection to a central filtration system

X-Tractor 5A

X-Tractor 8A

See E13.19 for complete specs. X-Tractor 3A

X-Tractor 3A, 5A & 8A • High vacuum systems designed to provide

suction for attached nozzles or fume extraction guns

• Perfect for heavy-duty semiautomatic and on-torch applications

• SCFM: 165-475 CFM• Automatic filter cleaning

Statiflex 200-M Single Arm Base Unit

See E14.744 and E14.746 for complete specs.

See MC11-37 for complete specs.

VIKING™ 3350 & 3250D FGS® PAPR SYSTEMS Powered Air Purifying Respirator Welding Helmets• Complete wearable system that purifies ambient air from the shop

and delivers filtered air to the user• Premium 4C® optics and extra-large 12.5 sq. in. viewing area • 8 to 16 Hour Battery Life Options Available• Intelligent blower system with HEPA filter• Designed for confined spaces and all day comfort

Mobiflex® 200-M & 400-MS (MERV 12, MERV 14 & MERV 16 Filter Configurations)

Mobiflex® 200-M

See E13.21 for complete specs.

• Lightweight, low vacuum mobile fume extractor• Designed for maintenance departments, general/heavy

fabrication and job shops that require fume extraction in multiple locations

• SCFM: 735 CFM with LFA 3.1/4.1 extraction arm• Large 538ft2 and 325ft2 surface areas• Available with automatic cleaning or disposable filters

Mobiflex® 400-MS

See E13.17 for complete specs.

X-Tractor® 1GC• Lightweight and portable, high vacuum extraction unit• Perfect for light duty welding applications• Connects to a fume gun or extraction nozzle• SCFM: 55-115 CFM• Unique, manually operated rotary air jet system

for filter cleaning

K4260-4 One-Pak Package

Magnum® PRO 350 / 550 Fume Extraction Guns

Magnum PRO 350Magnum PRO 550See E12.02 for complete specs.

• Line of semiautomatic air-cooled fume extraction guns• Intended for confined spaces in high productivity

fabrication and production environments• Source extraction for various wire processes • Wire diameter range: .035 – 1/8 in. (0.9 - 3.2 mm)• Innovative Strain Relief - Swivels to take pressure off the

operator’s wrist, allowing for added comfort

SOURCE LOCAL GENERALCapture Fume at the Arc Isolated Fume Extraction Facility-wide Fume Extraction Solutions

ENVIRONMENTAL PRODUCTS SELECTION GUIDE

Extraction ArmsLTA 2.0-CW Telescopic Extraction Arm (Counter Weight)

See E13.51 for complete specs.

• Available in 4ft-7ft wall widths

• Single or multiple booth options (Square or Rectangle)

• Heavy-duty steel construction

• Available accessories include a variety of welding table designs, welding curtains, a lockable storage cabinet and LED Light Kits.

Welding Booths• A complete system to prevent, detect and suppress

fires in welding and plasma cutting fume filtration systems – reducing the risk of fire to a minimum

• Divided into prevention, detection, and suppression

See MC12-05 for complete specs.

• Ideal for robotic, hard automation, manual, and plasma cutting applications

• Engineered to contain and extract welding, cutting, arc gouging, and grinding fume from the work environment

Modular Extraction Hoods• Ideal solution for welding fume

extraction on robotic cells

• Comes in standard sizes or can be customized to fit a non-standard sized cell

Formed Extraction Hoods

LFA Extraction Arms

Spark Guardian™