FARO Laser Tracker Product Catalog Language: English-US August
english product catalog 2010
-
Upload
emfils-industria-e-comercio-de-produtos-odontologicos -
Category
Documents
-
view
227 -
download
2
description
Transcript of english product catalog 2010
PRODUCT CATALOG COLOSSO IMPLANTS SYSTEMLIVING THE PRACTICALITY
Working to make the world smile
- FIRST IMPLANT SYSTEM DEVELOPED IN BRAzIL SuPPORTED BY A DOcTORAL ThESIS
- REASONED IN SIMPLIcITY, SEcuRITY AND cONVENIENcE cLINIc
- FIRST IMPLANT wITh SuRFAcE TREATMENT TO ThE TOP
- ThE SMALLEST wORLD DENTAL TEchNIcIAN KIT (ONE KEY)
- SuRgIcAL INSTRuMENTS AND PROSThETIc OPTIMIzED
- cERTIFIED cOMPANY
- OVER 98% OF cuSTOMER SATISFAcTION
- ScIENTIFIc SuPPORT AVAILABLE FOR cLINIcAL QuESTIONS
ThE cOMPANY
Since its founding in 1998, Emfils, a leading provider of dental implants in Brazil, brings to market a product line that meets all the needs of professionals.
Its mission is to provide an implant system practical, safe and efficient access to dentists with the best value in the market and, thus, enabling the implant treatment to more people.
Since its inception, Emfils is dedicated to enabling continued research to optimize the time of the dentists in their daily practice with maximum security. Their releases always gather what is most modern in the world market, with the characteristic that only Emfils offers: practicality in its design!
The production process of Emfils is one of the most advanced in the market. With the latest technology in micromachining, the company ensures accuracy and repeatability of all products it manufactures.
Emfils follow the strictest international quality standards, in accordance with ISO 9001, ISO13485, MDD 93/42/EEC and DRC-59 (ANVISA) procedures that ensure accuracy and control of all their products.
NATO is the center of studies, development and dissemination of the Colosso implants and has a clinical staff and highly qualified technical and scientific. Residents of surgery, prosthesis and graduate students regularly seek professional development in NATO.
According to the mission of Emfils, the NATO viable clinically therapy to implant a larger number of people.
The Clinical Director of NATO is Professor Dr. Adolfo Embacher Filho. Pioneer changed the paradigms of the implant system in of inserting implants, technical and scientific improvements later adopted by the market and established worldwide. Specialist in Prosthodontics in Implant Dentistry and Doctor of Oral Surgery and Maxillofacial Traumatology in his 30 years of implant dentistry, has performed or supervised more than 15,000 implants.
SEE IN EMFIlS WEBSITE MANuAL OF PROcEDuRES
PROcEDuRES MANuAL
Training and information.
Emfils, committed to lead and provide as much information about their products, has developed a complete Procedures Manual with rich information about the Implant System.
In this manual, in addition to knowing specific technical details of each product, you can also study and analyze real clinical cases with photographs that show details of each step, whether surgical or prosthetic.
STuDY, DEVELOPMENTAND DIVuLgATION cENTERFOR cOLOSSO IMPLANTS
INTERNAL HEXAGON IMPLANTcOLOSSO EcI EVOLuTION
7,0mm 8,5mm 10,0mm 11,5mm 13,0mm 14,5mm 16,0mm
Ø 3,3mm
Ø 4,0mm
Ø 5,0mm
3307 3308 3310 3311 3313 3314 3316
4007 4008 4010 4011 4013 4014 4016
5007 5008 5010 5011 5013 5014 5016
STANDARD HEALING CUP CPC-3302; CPC-3303; CPC-3304; CPC-3305; CPC-3306;CPC-4002; CPC-4003; CPC-4004; CPC-4005; CPC-4006;CPC-5002; CPC-5003; CPC-5004; CPC-5005; CPC-5006.
STANDARD AESTHETIC HEALING CUPCEC-3342; CEC-3343; CEC-3344; CEC-3345; CEC-3346;CEC-4052; CEC-4053; CEC-4054; CEC-4055; CEC-4056;CEC-5062; CEC-5063; CEC-5064; CEC-5065; CEC-5066.
same prostheti c
att achment
switchingplat.
screw M2
product
SEE IN EMFIlS WEBSITE MANuAL OF PROcEDuRES
70N.cm
Surgical maximum
torque
NON-ROTATIONAl TRANSMuCOSAl ABuTMENT PTHC-3302; PTHC-3303; PTHC-3304; PTHC-3305; PTHC-3306;PTHC-4002; PTHC-4003; PTHC-4004; PTHC-4005; PTHC-4006;PTHC-5002; PTHC-5003; PTHC-5004; PTHC-5005; PTHC-5006.
TITANIUM TRANSMUCOSAL ABuTMENT PTC-3302; PTC-3303; PTC-3304; PTC-3305; PTC-3306; PTC-4002; PTC-4003; PTC-4004; PTC-4005; PTC-4006;PTC-5002; PTC-5003; PTC-5004; PTC-5005; PTC-5006.
TITANIUM ANGLED TRANSMUCOSAL ABuTMENT PTA-33153; PTA-33154; PTA-33155; PTA-33156;PTA-33203; PTA-33204; PTA-33205; PTA-33206;PTA-40153; PTA-40154; PTA-40155; PTA-40156;PTA-40204; PTA-40205; PTA-40206; PTA-40207;PTA-50153; PTA-50154; PTA-50155; PTA-50156; PTA-50204; PTA-50205; PTA-50206; PTA-50207.
TRANSFER ABuTMENT TRANSMUCOSALClOSED TRAy FOR PTCPTT-4012; PTT-5012.
TRANSFER ABuTMENTClOSED TRAy FOR PThCTFPThC-4013; TFPThC-5013.
TRANSFER ABuTMENTClOSED TRAy FOR PTPTFPTP-4013; TFPTP-5013.
TRANSFER ABuTMENT ClOSED TRAy FOR ANglED TRANSMUCOSALTFPTA-5012; TFPTA-6012.
TRANSFER ABuTMENT TRANSMUCOSALOPEN TRAy FOR PTCPTTA-4012; PTTA-5012.
TRANSFER ABuTMENTOPEN TRAy FOR PThCTAPThC-4013; TAPThC-5013.
TRANSFER ABuTMENTOPEN TRAy FOR PTPTAPTP-4013; TAPTP-5013.
TRANSFER ABuTMENT OPEN TRAy FOR ANglED TRANSMUCOSAL TAPTA-5012; TAPTA-6012.
STANDARD TRANSMUCOSALABuTMENT PROTECTION PPP-4004; PPP-5004.
PROTECTI ON FOR NON-ROTATIONAlTRANSMUCOSAL ABuTMENTSPPT-4004; PPT-5004.
PROTECTI ON FOR ThE TITANIUM TRANSMUCOSAL ABuTMENTSPPT-4004; PPT-5004.
TRANSMUCOSALANglED ABuTMENT PROTECTIONPPTA-5051; PPTA-6051.
ANAlOg OF ThE STANDARD TRANSMUCOSAL ABuTMENTPTPA-4010; PTPA-5010.
ANAlOg OF ThE NON-ROTATI ONAlTRANSMUCOSAL ABuTMENTPThCA-4012; PThCA-5012.
ANAlOg OF ThE TITANIuM TRANSMUCOSALABuTMENTPTCA-4012; PTCA-5012.
ANAlOg OF ThE STANDARD TRANSMUCOSAL ABuTMENTPTAA-5013; PTAA-6013.
BuRNOuT NON-ROTATI ONAl ABuTMENT WITh CrCoMo EDgE OF ThE NON-ROTATIONAl TRANSMUCOSAL PlETh-4015; PlETh-5015.
BuRNOuT ROTATI ONAl ABuTMENT WITh CrCoMoEDgE OF ThE ANglED TRANSMUCOSALPlETA-5015; PlETA-6015.
BuRNOuT ROTATIONAl ABuTMENT WITh CrCoMoEDgE OF ThE TRANSMUCOSALPlET-4015; PlET-5015.
BuRNOuT ABuTMENT OF THE TRANSMUCOSALPPET-4015; PPET-5015.
BuRNOuT NON-ROTATIONAl ABuTMENT OF ThE NON-ROTATIONAl TRANSMUCOSAL PETh-4015; PETh-5015.
BuRNOuT ABuTMENT WITH CrCoMo EDGEOF ThE TRANSMuCOSAl STANDARDPElP-4015; PElP-5015.
BuRNOuT ABuTMENTOF ThE TRANSMuCOSAl STANDARDPEPP-4015; PEPP-5015.
BuRNOuT ABuTMENT OF ThE ANglEDTRANSMUCOSAL PETA-5015; PETA-6015.
TITANIuM ABuTMENT WITh HEXAGONPTCh-3315; PTCh-4015; PTCh-5015.
BuRNOuT ABuTMENT WITH HEXAGON PPCh-3315; PPCh-4015; PPCh-5015.
BuRNOuT ABuTMENT WITh CrCoMo EDGE AND HEXAGONPPlEh-3315; PPlEh-4015; PPlEh-5015.
TITANIuM ABuTMENT WITHOUT HEXAGONPTSh-3315; PTSh-4015; PTSh-5015.
BuRNOuT ABuTMENT WITHOUT HEXAGONPPSh-3315; PPSh-4015; PPSh-5015.
BuRNOuT ABuTMENT WITh CrCoMo EDGE WITHOUT HEXAGONPPlE-3315; PPlE-4015; PPlE-5015.
STANDARD TRANSMUCOSAL ABuTMENT PTP-3303; PTP-3304; PTP-3305; PTP-3306; PTP-4003; PTP-4004; PTP-4005; PTP-4006; PTP-5003; PTP-5004; PTP-5005; PTP-5006.
TRANSFER ABuTMENT CLOSED TRAY PTMF-3312; PTMF-4012; PTMF-5012.
TRANSFER ABuTMENT WITh REMOVABlE HEXAGONPTHR-3312; PTHR-4012; PThR-5012.
TRANSFER ABuTMENT OPEN TRAYPTMA-3312; PTMA-4012; PTMA-5012.
ANAlOg OF INTERNAl HEXAGON IMPLANT ECI AND CRC EVOLUTION ACI-3310; ACI-4010; ACI-5010.
ADJuSTABlE STANDARD ABuTMENT PPL-3314; PPL-4014; PPL-5014;PPC-3311; PPC-4011; PPC-5011.
hEXAgONAl ABuTMENT PHC-3302; PHC-3304; PHC-3306;PHC-4002; PHC-4004; PHC-4006;PHC-5002; PHC-5004; PHC-5006.
ANglED ADJuSTABlE ABuTMENT WITh BANDPAC-33151; PAC-33152; PAC-33153; PAC-33251; PAC-33252; PAC-33253;PAC-40151; PAC-40152; PAC-40153; PAC-40251; PAC-40252; PAC-40253;PAC-50151; PAC-50152; PAC-50153; PAC-50251; PAC-50252; PAC-50253.
ADJuSTABlE AESThETIC ABuTMENT PEC-3311; PEC-4011; PEC-5011.
ADJuSTABlE ANglED ABuTMENT PAC-3315; PAC-4015; PAC-5015;PAC-3325; PAC-4025; PAC-5025.
SELECTION OF PROSThETIc cOMPONENTS INTERNAL hEXAgON
scre
wed
pro
sthe
sis
abut
men
t
O´RING RETENTION ABuTMENT PRO-3301; PRO-3302; PRO-3303; PRO-3304; PRO-3305; PRO-3306;PRO-4001; PRO-4002; PRO-4003; PRO-4004; PRO-4005; PRO-4006;PRO-5001; PRO-5002; PRO-5003; PRO-5004; PRO-5005; PRO-5006.
O´RINg RETENTION BuRNOuT MINI-ABuTMENT MPPO-3010
ce
men
ted
or s
crew
ed p
rost
hesi
s
pros
thes
is o
ver d
entu
re
cem
ente
d pr
osth
esis
abu
tmen
t
clinical laboratory
TRANSFER ABuTMENT WITh REMOVABlE
TRANSFER ABuTMENT
15° 25°
15° 25°
*
* 30 N.cm prostheti c torque
*
*
*
**
**
*
**
**
**
*
90N.cm
Surgical maximum
torque
90N.cm
Surgical maximum
torque
NON-ROTATIONAl TRANSMuCOSAl ABuTMENT PTHC-3302; PTHC-3303; PTHC-3304; PTHC-3305; PTHC-3306;PTHC-4002; PTHC-4003; PTHC-4004; PTHC-4005; PTHC-4006;PTHC-5002; PTHC-5003; PTHC-5004; PTHC-5005; PTHC-5006.
TITANIUM TRANSMUCOSAL ABuTMENT PTC-3302; PTC-3303; PTC-3304; PTC-3305; PTC-3306; PTC-4002; PTC-4003; PTC-4004; PTC-4005; PTC-4006;PTC-5002; PTC-5003; PTC-5004; PTC-5005; PTC-5006.
TITANIUM ANGLED TRANSMUCOSAL ABuTMENT PTA-33153; PTA-33154; PTA-33155; PTA-33156;PTA-33203; PTA-33204; PTA-33205; PTA-33206;PTA-40153; PTA-40154; PTA-40155; PTA-40156;PTA-40204; PTA-40205; PTA-40206; PTA-40207;PTA-50153; PTA-50154; PTA-50155; PTA-50156; PTA-50204; PTA-50205; PTA-50206; PTA-50207.
TRANSFER ABuTMENT TRANSMUCOSALClOSED TRAy FOR PTCPTT-4012; PTT-5012.
TRANSFER ABuTMENTClOSED TRAy FOR PThCTFPThC-4013; TFPThC-5013.
TRANSFER ABuTMENTClOSED TRAy FOR PTPTFPTP-4013; TFPTP-5013.
TRANSFER ABuTMENT ClOSED TRAy FOR ANglED TRANSMUCOSALTFPTA-5012; TFPTA-6012.
TRANSFER ABuTMENT TRANSMUCOSALOPEN TRAy FOR PTCPTTA-4012; PTTA-5012.
TRANSFER ABuTMENTOPEN TRAy FOR PThCTAPThC-4013; TAPThC-5013.
TRANSFER ABuTMENTOPEN TRAy FOR PTPTAPTP-4013; TAPTP-5013.
TRANSFER ABuTMENT OPEN TRAy FOR ANglED TRANSMUCOSAL TAPTA-5012; TAPTA-6012.
STANDARD TRANSMUCOSALABuTMENT PROTECTION PPP-4004; PPP-5004.
PROTECTI ON FOR NON-ROTATIONAlTRANSMUCOSAL ABuTMENTSPPT-4004; PPT-5004.
PROTECTI ON FOR ThE TITANIUM TRANSMUCOSAL ABuTMENTSPPT-4004; PPT-5004.
TRANSMUCOSALANglED ABuTMENT PROTECTIONPPTA-5051; PPTA-6051.
ANAlOg OF ThE STANDARD TRANSMUCOSAL ABuTMENTPTPA-4010; PTPA-5010.
ANAlOg OF ThE NON-ROTATI ONAlTRANSMUCOSAL ABuTMENTPThCA-4012; PThCA-5012.
ANAlOg OF ThE TITANIuM TRANSMUCOSALABuTMENTPTCA-4012; PTCA-5012.
ANAlOg OF ThE STANDARD TRANSMUCOSAL ABuTMENTPTAA-5013; PTAA-6013.
BuRNOuT NON-ROTATI ONAl ABuTMENT WITh CrCoMo EDgE OF ThE NON-ROTATIONAl TRANSMUCOSAL PlETh-4015; PlETh-5015.
BuRNOuT ROTATI ONAl ABuTMENT WITh CrCoMoEDgE OF ThE ANglED TRANSMUCOSALPlETA-5015; PlETA-6015.
BuRNOuT ROTATIONAl ABuTMENT WITh CrCoMoEDgE OF ThE TRANSMUCOSALPlET-4015; PlET-5015.
BuRNOuT ABuTMENT OF THE TRANSMUCOSALPPET-4015; PPET-5015.
BuRNOuT NON-ROTATIONAl ABuTMENT OF ThE NON-ROTATIONAl TRANSMUCOSAL PETh-4015; PETh-5015.
BuRNOuT ABuTMENT WITH CrCoMo EDGEOF ThE TRANSMuCOSAl STANDARDPElP-4015; PElP-5015.
BuRNOuT ABuTMENTOF ThE TRANSMuCOSAl STANDARDPEPP-4015; PEPP-5015.
BuRNOuT ABuTMENT OF ThE ANglEDTRANSMUCOSAL PETA-5015; PETA-6015.
TITANIuM ABuTMENT WITh HEXAGONPTCh-3315; PTCh-4015; PTCh-5015.
BuRNOuT ABuTMENT WITH HEXAGON PPCh-3315; PPCh-4015; PPCh-5015.
BuRNOuT ABuTMENT WITh CrCoMo EDGE AND HEXAGONPPlEh-3315; PPlEh-4015; PPlEh-5015.
TITANIuM ABuTMENT WITHOUT HEXAGONPTSh-3315; PTSh-4015; PTSh-5015.
BuRNOuT ABuTMENT WITHOUT HEXAGONPPSh-3315; PPSh-4015; PPSh-5015.
BuRNOuT ABuTMENT WITh CrCoMo EDGE WITHOUT HEXAGONPPlE-3315; PPlE-4015; PPlE-5015.
STANDARD TRANSMUCOSAL ABuTMENT PTP-3303; PTP-3304; PTP-3305; PTP-3306; PTP-4003; PTP-4004; PTP-4005; PTP-4006; PTP-5003; PTP-5004; PTP-5005; PTP-5006.
TRANSFER ABuTMENT CLOSED TRAY PTMF-3312; PTMF-4012; PTMF-5012.
TRANSFER ABuTMENT WITh REMOVABlE HEXAGONPTHR-3312; PTHR-4012; PThR-5012.
TRANSFER ABuTMENT OPEN TRAYPTMA-3312; PTMA-4012; PTMA-5012.
ANAlOg OF INTERNAl HEXAGON IMPLANT ECI AND CRC EVOLUTION ACI-3310; ACI-4010; ACI-5010.
ADJuSTABlE STANDARD ABuTMENT PPL-3314; PPL-4014; PPL-5014;PPC-3311; PPC-4011; PPC-5011.
hEXAgONAl ABuTMENT PHC-3302; PHC-3304; PHC-3306;PHC-4002; PHC-4004; PHC-4006;PHC-5002; PHC-5004; PHC-5006.
ANglED ADJuSTABlE ABuTMENT WITh BANDPAC-33151; PAC-33152; PAC-33153; PAC-33251; PAC-33252; PAC-33253;PAC-40151; PAC-40152; PAC-40153; PAC-40251; PAC-40252; PAC-40253;PAC-50151; PAC-50152; PAC-50153; PAC-50251; PAC-50252; PAC-50253.
ADJuSTABlE AESThETIC ABuTMENT PEC-3311; PEC-4011; PEC-5011.
ADJuSTABlE ANglED ABuTMENT PAC-3315; PAC-4015; PAC-5015;PAC-3325; PAC-4025; PAC-5025.
SELECTION OF PROSThETIc cOMPONENTS INTERNAL hEXAgON
scre
wed
pro
sthe
sis
abut
men
t
O´RING RETENTION ABuTMENT PRO-3301; PRO-3302; PRO-3303; PRO-3304; PRO-3305; PRO-3306;PRO-4001; PRO-4002; PRO-4003; PRO-4004; PRO-4005; PRO-4006;PRO-5001; PRO-5002; PRO-5003; PRO-5004; PRO-5005; PRO-5006.
O´RINg RETENTION BuRNOuT MINI-ABuTMENT MPPO-3010
ce
men
ted
or s
crew
ed p
rost
hesi
s
pros
thes
is o
ver d
entu
re
cem
ente
d pr
osth
esis
abu
tmen
t
clinical laboratory
15° 25°
15° 25°
*
* 30 N.cm prostheti c torque
*
*
*
**
**
*
**
**
**
*
7,0mm 8,5mm 10,0mm 11,5mm 13,0mm 14,5mm 16,0mm
Ø 3,3mm
Ø 4,0mm
Ø 5,0mm
3307 3308 3310 3311 3313 3314 3316
4007 4008 4010 4011 4013 4014 4016
5007 5008 5010 5011 5013 5014 5016
INTERNAL HEXAGON IMPLANTcOLOSSO cRc EVOLuTION
STANDARD HEALING CUPCPC-3302; CPC-3303; CPC-3304; CPC-3305; CPC-3306;CPC-4002; CPC-4003; CPC-4004; CPC-4005; CPC-4006;CPC-5002; CPC-5003; CPC-5004; CPC-5005; CPC-5006.
STANDARD AESTHETIC HEALING CUPCEC-3342; CEC-3343; CEC-3344; CEC-3345; CEC-3346;CEC-4052; CEC-4053; CEC-4054; CEC-4055; CEC-4056;CEC-5062; CEC-5063; CEC-5064; CEC-5065; CEC-5066.
NON-ROTATIONAl TRANSMuCOSAl ABuTMENTPTHC-3302; PTHC-3303; PTHC-3304; PTHC-3305; PTHC-3306;PTHC-4002; PTHC-4003; PTHC-4004; PTHC-4005; PTHC-4006;PTHC-5002; PTHC-5003; PTHC-5004; PTHC-5005; PTHC-5006.
TITANIUM TRANSMUCOSAL ABuTMENTPTC-3302; PTC-3303; PTC-3304; PTC-3305; PTC-3306; PTC-4002; PTC-4003; PTC-4004; PTC-4005; PTC-4006;PTC-5002; PTC-5003; PTC-5004; PTC-5005; PTC-5006.
TITANIUM ANGLED TRANSMUCOSAL ABuTMENT PTA-33153; PTA-33154; PTA-33155; PTA-33156;PTA-33203; PTA-33204; PTA-33205; PTA-33206;PTA-40153; PTA-40154; PTA-40155; PTA-40156;PTA-40204; PTA-40205; PTA-40206; PTA-40207;PTA-50153; PTA-50154; PTA-50155; PTA-50156; PTA-50204; PTA-50205; PTA-50206; PTA-50207.
TRANSFER ABuTMENT TRANSMUCOSALClOSED TRAy FOR PTCPTT-4012; PTT-5012.
TRANSFER ABuTMENTClOSED TRAy FOR PThCTFPThC-4013; TFPThC-5013.
TRANSFER ABuTMENTClOSED TRAy FOR PTPTFPTP-4013; TFPTP-5013.
TRANSFER ABuTMENT ClOSED TRAy FOR ANglED TRANSMUCOSAL TFPTA-5012; TFPTA-6012.
TRANSFER ABuTMENT TRANSMUCOSALOPEN TRAy FOR PTCPTTA-4012; PTTA-5012.
TRANSFER ABuTMENTOPEN TRAy FOR PThCTAPThC-4013; TAPThC-5013.
TRANSFER ABuTMENTOPEN TRAy FOR PTPTAPTP-4013; TAPTP-5013.
TRANSFER ABuTMENT OPEN TRAy FOR ANglED TRANSMUCOSAL TAPTA-5012; TAPTA-6012.
STANDARD TRANSMUCOSALABuTMENT PROTECTI ONPPP-4004; PPP-5004.
PROTECTI ON FOR NON-ROTATIONAlTRANSMUCOSAL ABuTMENTSPPT-4004; PPT-5004.
PROTECTI ON FOR ThE TITANIUM TRANSMUCOSAL ABuTMENTSPPT-4004; PPT-5004.
TRANSMUCOSALANglED ABuTMENT PROTECTIONPPTA-5051; PPTA-6051.
ANAlOg OF ThE STANDARD TRANSMUCOSAL ABuTMENTPTPA-4010; PTPA-5010.
ANAlOg OF ThE NON-ROTATI ONAlTRANSMUCOSAL ABuTMENT PThCA-4012; PThCA-5012.
ANAlOg OF ThE TITANIuM TRANSMUCOSALABuTMENTPTCA-4012; PTCA-5012.
ANAlOg OF ThE STANDARD TRANSMUCOSAL ABuTMENTPTAA-5013; PTAA-6013.
BuRNOuT NON-ROTATI ONAl ABuTMENT WITh CrCoMo EDgE OF ThE NON-ROTATIONAl TRANSMUCOSALPlETh-4015; PlETh-5015.
BuRNOuT ROTATI ONAl ABuTMENT WITh CrCoMoEDgE OF ThE ANglED TRANSMUCOSALPlETA-5015; PlETA-6015.
BuRNOuT ROTATIONAl ABuTMENT WITh CrCoMoEDgE OF ThE TRANSMUCOSAL PlET-4015; PlET-5015.
BuRNOuT ABuTMENT OF THE TRANSMUCOSALPPET-4015; PPET-5015.
BuRNOuT NON-ROTATIONAl ABuTMENT OF ThE NON-ROTATIONAl TRANSMUCOSALPETh-4015; PETh-5015.
BuRNOuT ABuTMENT WITH CrCoMo EDGEOF ThE TRANSMuCOSAl STANDARDPElP-4015; PElP-5015.
BuRNOuT ABuTMENTOF ThE TRANSMuCOSAl STANDARDPEPP-4015; PEPP-5015.
BuRNOuT ABuTMENT OF ThE ANglEDTRANSMUCOSALPETA-5015; PETA-6015.
TITANIuM ABuTMENT WITh HEXAGONPTCh-3315; PTCh-4015; PTCh-5015.
BuRNOuT ABuTMENT WITH HEXAGON PPCh-3315; PPCh-4015; PPCh-5015.
BuRNOuT ABuTMENT WITh CrCoMo EDGE AND HEXAGONPPlEh-3315; PPlEh-4015; PPlEh-5015.
TITANIuM ABuTMENT WITHOUT HEXAGONPTSh-3315; PTSh-4015; PTSh-5015.
BuRNOuT ABuTMENT WITHOUT HEXAGONPPSh-3315; PPSh-4015; PPSh-5015.
BuRNOuT ABuTMENT WITh CrCoMo EDGE WITHOUT HEXAGONPPlE-3315; PPlE-4015; PPlE-5015.
STANDARD TRANSMUCOSAL ABuTMENTPTP-3303; PTP-3304; PTP-3305; PTP-3306; PTP-4003; PTP-4004; PTP-4005; PTP-4006; PTP-5003; PTP-5004; PTP-5005; PTP-5006.
TRANSFER ABuTMENT CLOSED TRAYPTMF-3312; PTMF-4012; PTMF-5012.
TRANSFER ABuTMENT WITh REMOVABlE HEXAGON PTHR-3312; PTHR-4012; PThR-5012.
TRANSFER ABuTMENT OPEN TRAY PTMA-3312; PTMA-4012; PTMA-5012.
ANAlOg OF INTERNAl HEXAGON IMPLANT ECI AND CRC EVOLUTION ACI-3310; ACI-4010; ACI-5010.
ADJuSTABlE STANDARD ABuTMENTPPL-3314; PPL-4014; PPL-5014;PPC-3311; PPC-4011; PPC-5011.
ADJuSTABlE STANDARD ABuTMENT PHC-3302; PHC-3304; PHC-3306;PHC-4002; PHC-4004; PHC-4006;PHC-5002; PHC-5004; PHC-5006.
ANglED ADJuSTABlE ABuTMENT WITh BANDPAC-33151; PAC-33152; PAC-33153; PAC-33251; PAC-33252; PAC-33253;PAC-40151; PAC-40152; PAC-40153; PAC-40251; PAC-40252; PAC-40253;PAC-50151; PAC-50152; PAC-50153; PAC-50251; PAC-50252; PAC-50253.
ADJuSTABlE AESThETIC ABuTMENT PEC-3311; PEC-4011; PEC-5011.
ADJuSTABlE ANglED ABuTMENT PAC-3315; PAC-4015; PAC-5015;PAC-3325; PAC-4025; PAC-5025.
SELECTION OF PROSThETIc cOMPONENTS INTERNAL hEXAgON
scre
wed
pro
sthe
sis
abut
men
t
O´RING RETENTION ABuTMENTPRO-3301; PRO-3302; PRO-3303; PRO-3304; PRO-3305; PRO-3306;PRO-4001; PRO-4002; PRO-4003; PRO-4004; PRO-4005; PRO-4006;PRO-5001; PRO-5002; PRO-5003; PRO-5004; PRO-5005; PRO-5006.
O´RINg RETENTION BuRNOuT MINI-ABuTMENTMPPO-3010
cem
ente
d or
scr
ewed
pro
sthe
sis
pros
thes
is o
ver d
entu
re
cem
ente
d pr
osth
esis
abu
tmen
t
clinical laboratory
TRANSFER ABuTMENT WITh REMOVABlE
TRANSFER ABuTMENT
15° 25°
15° 25°
*
* 30 N.cm prostheti c torque
*
*
*
**
**
*
**
**
**
*
same prostheti c
att achment
switchingplat.
screw M2
product
SEE IN EMFIlS WEBSITE MANuAL OF PROcEDuRES
70N.cm
Surgical maximum
torque
90N.cm
Surgical maximum
torque
90N.cm
Surgical maximum
torque
NON-ROTATIONAl TRANSMuCOSAl ABuTMENTPTHC-3302; PTHC-3303; PTHC-3304; PTHC-3305; PTHC-3306;PTHC-4002; PTHC-4003; PTHC-4004; PTHC-4005; PTHC-4006;PTHC-5002; PTHC-5003; PTHC-5004; PTHC-5005; PTHC-5006.
TITANIUM TRANSMUCOSAL ABuTMENTPTC-3302; PTC-3303; PTC-3304; PTC-3305; PTC-3306; PTC-4002; PTC-4003; PTC-4004; PTC-4005; PTC-4006;PTC-5002; PTC-5003; PTC-5004; PTC-5005; PTC-5006.
TITANIUM ANGLED TRANSMUCOSAL ABuTMENT PTA-33153; PTA-33154; PTA-33155; PTA-33156;PTA-33203; PTA-33204; PTA-33205; PTA-33206;PTA-40153; PTA-40154; PTA-40155; PTA-40156;PTA-40204; PTA-40205; PTA-40206; PTA-40207;PTA-50153; PTA-50154; PTA-50155; PTA-50156; PTA-50204; PTA-50205; PTA-50206; PTA-50207.
TRANSFER ABuTMENT TRANSMUCOSALClOSED TRAy FOR PTCPTT-4012; PTT-5012.
TRANSFER ABuTMENTClOSED TRAy FOR PThCTFPThC-4013; TFPThC-5013.
TRANSFER ABuTMENTClOSED TRAy FOR PTPTFPTP-4013; TFPTP-5013.
TRANSFER ABuTMENT ClOSED TRAy FOR ANglED TRANSMUCOSAL TFPTA-5012; TFPTA-6012.
TRANSFER ABuTMENT TRANSMUCOSALOPEN TRAy FOR PTCPTTA-4012; PTTA-5012.
TRANSFER ABuTMENTOPEN TRAy FOR PThCTAPThC-4013; TAPThC-5013.
TRANSFER ABuTMENTOPEN TRAy FOR PTPTAPTP-4013; TAPTP-5013.
TRANSFER ABuTMENT OPEN TRAy FOR ANglED TRANSMUCOSAL TAPTA-5012; TAPTA-6012.
STANDARD TRANSMUCOSALABuTMENT PROTECTI ONPPP-4004; PPP-5004.
PROTECTI ON FOR NON-ROTATIONAlTRANSMUCOSAL ABuTMENTSPPT-4004; PPT-5004.
PROTECTI ON FOR ThE TITANIUM TRANSMUCOSAL ABuTMENTSPPT-4004; PPT-5004.
TRANSMUCOSALANglED ABuTMENT PROTECTIONPPTA-5051; PPTA-6051.
ANAlOg OF ThE STANDARD TRANSMUCOSAL ABuTMENTPTPA-4010; PTPA-5010.
ANAlOg OF ThE NON-ROTATI ONAlTRANSMUCOSAL ABuTMENT PThCA-4012; PThCA-5012.
ANAlOg OF ThE TITANIuM TRANSMUCOSALABuTMENTPTCA-4012; PTCA-5012.
ANAlOg OF ThE STANDARD TRANSMUCOSAL ABuTMENTPTAA-5013; PTAA-6013.
BuRNOuT NON-ROTATI ONAl ABuTMENT WITh CrCoMo EDgE OF ThE NON-ROTATIONAl TRANSMUCOSALPlETh-4015; PlETh-5015.
BuRNOuT ROTATI ONAl ABuTMENT WITh CrCoMoEDgE OF ThE ANglED TRANSMUCOSALPlETA-5015; PlETA-6015.
BuRNOuT ROTATIONAl ABuTMENT WITh CrCoMoEDgE OF ThE TRANSMUCOSAL PlET-4015; PlET-5015.
BuRNOuT ABuTMENT OF THE TRANSMUCOSALPPET-4015; PPET-5015.
BuRNOuT NON-ROTATIONAl ABuTMENT OF ThE NON-ROTATIONAl TRANSMUCOSALPETh-4015; PETh-5015.
BuRNOuT ABuTMENT WITH CrCoMo EDGEOF ThE TRANSMuCOSAl STANDARDPElP-4015; PElP-5015.
BuRNOuT ABuTMENTOF ThE TRANSMuCOSAl STANDARDPEPP-4015; PEPP-5015.
BuRNOuT ABuTMENT OF ThE ANglEDTRANSMUCOSALPETA-5015; PETA-6015.
TITANIuM ABuTMENT WITh HEXAGONPTCh-3315; PTCh-4015; PTCh-5015.
BuRNOuT ABuTMENT WITH HEXAGON PPCh-3315; PPCh-4015; PPCh-5015.
BuRNOuT ABuTMENT WITh CrCoMo EDGE AND HEXAGONPPlEh-3315; PPlEh-4015; PPlEh-5015.
TITANIuM ABuTMENT WITHOUT HEXAGONPTSh-3315; PTSh-4015; PTSh-5015.
BuRNOuT ABuTMENT WITHOUT HEXAGONPPSh-3315; PPSh-4015; PPSh-5015.
BuRNOuT ABuTMENT WITh CrCoMo EDGE WITHOUT HEXAGONPPlE-3315; PPlE-4015; PPlE-5015.
STANDARD TRANSMUCOSAL ABuTMENTPTP-3303; PTP-3304; PTP-3305; PTP-3306; PTP-4003; PTP-4004; PTP-4005; PTP-4006; PTP-5003; PTP-5004; PTP-5005; PTP-5006.
TRANSFER ABuTMENT CLOSED TRAYPTMF-3312; PTMF-4012; PTMF-5012.
TRANSFER ABuTMENT WITh REMOVABlE HEXAGON PTHR-3312; PTHR-4012; PThR-5012.
TRANSFER ABuTMENT OPEN TRAY PTMA-3312; PTMA-4012; PTMA-5012.
ANAlOg OF INTERNAl HEXAGON IMPLANT ECI AND CRC EVOLUTION ACI-3310; ACI-4010; ACI-5010.
ADJuSTABlE STANDARD ABuTMENTPPL-3314; PPL-4014; PPL-5014;PPC-3311; PPC-4011; PPC-5011.
ADJuSTABlE STANDARD ABuTMENT PHC-3302; PHC-3304; PHC-3306;PHC-4002; PHC-4004; PHC-4006;PHC-5002; PHC-5004; PHC-5006.
ANglED ADJuSTABlE ABuTMENT WITh BANDPAC-33151; PAC-33152; PAC-33153; PAC-33251; PAC-33252; PAC-33253;PAC-40151; PAC-40152; PAC-40153; PAC-40251; PAC-40252; PAC-40253;PAC-50151; PAC-50152; PAC-50153; PAC-50251; PAC-50252; PAC-50253.
ADJuSTABlE AESThETIC ABuTMENT PEC-3311; PEC-4011; PEC-5011.
ADJuSTABlE ANglED ABuTMENT PAC-3315; PAC-4015; PAC-5015;PAC-3325; PAC-4025; PAC-5025.
SELECTION OF PROSThETIc cOMPONENTS INTERNAL hEXAgON
scre
wed
pro
sthe
sis
abut
men
t
O´RING RETENTION ABuTMENTPRO-3301; PRO-3302; PRO-3303; PRO-3304; PRO-3305; PRO-3306;PRO-4001; PRO-4002; PRO-4003; PRO-4004; PRO-4005; PRO-4006;PRO-5001; PRO-5002; PRO-5003; PRO-5004; PRO-5005; PRO-5006.
O´RINg RETENTION BuRNOuT MINI-ABuTMENTMPPO-3010
cem
ente
d or
scr
ewed
pro
sthe
sis
pros
thes
is o
ver d
entu
re
cem
ente
d pr
osth
esis
abu
tmen
t
clinical laboratory
15° 25°
15° 25°
*
* 30 N.cm prostheti c torque
*
*
*
**
**
*
**
**
**
*
7,0mm 8,5mm 10,0mm 11,5mm 13,0mm 14,5mm 16,0mm
3307 3308 3310 3311 3313 3314 3316
4007 4008 4010 4011 4013 4014 4016
5007 5008 5010 5011 5013 5014 50165006
Ø 3,3mm
Ø 4,0mm
Ø 5,0mm
EXTERNAL HEXAGON IMPLANT cOLOSSO IhE EVOLuTION
6,0mm
SELECTION OF PROSThETIc cOMPONENTS INTERNAL hEXAgON
STANDARD HEALING CUPCPCHE-3502; CPCHE-3503; CPCHE-3504; CPCHE-3505; CPCHE-3506;CPCHE-4102; CPCHE-4103; CPCHE-4104; CPCHE-4105; CPCHE-4106;CPCHE-5002; CPCHE-5003; CPCHE-5004; CPCHE-5005; CPCHE-5006.
STANDARD AESTHETIC HEALING CUPCECHE-3542; CECHE-3543; CECHE-3544; CECHE-3545; CECHE-3546;CECHE-4152; CECHE-4153; CECHE-4154; CECHE-4155; CECHE-4156; CECHE-5062; CECHE-5063; CECHE-5064; CECHE-5065; CECHE-5066.
NON-ROTATIONAl TRANSMuCOSAl ABuTMENTPTHCHE-3503; PTHCHE-3504; PTHCHE-3505; PTHCHE-3506;PTHCHE-4103; PTHCHE-4104; PTHCHE-4105; PTHCHE-4106;PTHCHE-5003; PTHCHE-5004; PTHCHE-5005; PTHCHE-5006.
TITANIUM TRANSMUCOSAL ABuTMENT PTCHE-3502; PTCHE-3503; PTCHE-3504; PTCHE-3505; PTCHE-3506;PTCHE-4102; PTCHE-4103; PTCHE-4104; PTCHE-4105; PTCHE-4106;PTCHE-5002; PTCHE-5003; PTCHE-5004; PTCHE-5005; PTCHE-5006.
STANDARD TRANSMUCOSAL ABuTMENTPTPHE-3504; PTPHE-3505; PTPHE-3506;PTPHE-4104; PTPHE-4105; PTPHE-4106;PTPHE-5004; PTPHE-5005; PTPHE-5006.
TRANSFER ABuTMENT CLOSED TRAYPTMFhE-3512; PTMFhE-4112; PTMFhE-5012.
TRANSFER ABuTMENT OPEN TRAYPTMAHE-3512; PTMAHE-4112; PTMAhE-5012.
ANAlOg OF EXTERNAl HEXAGON IMPLANT HE EVOLUTION ACIhE-3510; ACIhE-4110; ACIhE-5010.
prostheti c platf orm
3,5mm
prostheti c platf orm4,1 mm
prostheti c platf orm5,0 mm
TRANSFER ABuTMENT
scre
wed
pro
sthe
sis
abut
men
tce
men
ted
pros
thes
is a
butm
ent
TRANSFER ABuTMENT
* 30 N.cm prostheti c torque
*
*
*
same prostheti c
att achment
switchingplat.
screw M2
product
SEE IN EMFIlS WEBSITE MANuAL OF PROcEDuRES
70N.cm
Surgical maximum
torque
90N.cm
Surgical maximum
torque
90N.cm
Surgical maximum
torque
TITANIuM ABuTMENT WITH HEXAGONPTCHHE-3515; PTCHHE-4115; PTChhE-5015.
BuRNOuT ABuTMENT WITH HEXAGONPPCHHE-3515; PPCHHE-4115; PPChhE-5015.
BuRNOuT ABuTMENT WITh CrCoMo EDGE AND HEXAGONPPLEHHE-3515; PPLEHHE-4115; PPlEhhE-5015.
TITANIuM ABuTMENT WITHOUT HEXAGONPTSHHE-3515; PTSHHE-4115; PTShhE-5015.
BuRNOuT ABuTMENT WITHOUT HEXAGONPPSHHE-3515; PPSHHE-4115; PPShhE-5015.
BuRNOuT ABuTMENT WITh CrCoMo EDGE WITHOUT HEXAGONPPLEHE-3515; PPLEHE-4115; PPlEhE-5015.
ADJuSTABlE STANDARD ABuTMENTPPLHE-3512; PPLHE-4112; PPLHE-5012;PPChE-3510; PPChE-4110; PPChE-5010.
ADJuSTABlE STANDARD ABuTMENTPHCHE-3502; PHCHE-3504; PHCHE-3506;PHCHE-4102; PHCHE-4104; PHCHE-4106;PHCHE-5002; PHCHE-5004; PHCHE-5006.
ANglED ADJuSTABlE ABuTMENT WITh BANDPACHE-35151; PACHE-35152; PACHE-35153; PACHE-35251; PACHE-35252; PACHE-35253;PACHE-41151; PACHE-41152; PACHE-41153; PACHE-41251; PACHE-41252; PACHE-41253;PACHE-50151; PACHE-50152; PACHE-50153; PACHE-50251; PACHE-50252; PACHE-50253.
ADJuSTABlE AESThETIC ABuTMENTPEChE-3511; PEChE-4111; PEChE-5011.
ADJuSTABlE ANglED ABuTMENTPACHE-3515; PACHE-4115; PACHE-5015;PAChE-3525; PAChE-4125; PAChE-5025.
O´RING RETENTION ABuTMENTPROHE-3501; PROHE-3502; PROHE-3503; PROHE-3504; PROHE-3505; PROHE-3506;PROHE-4101; PROHE-4102; PROHE-4103; PROHE-4104; PROHE-4105; PROHE-4106;PROHE-5001; PROHE-5002; PROHE-5003; PROhE-5004; PROhE-5005; PROhE-5006.
cem
ente
d or
scr
ewed
pro
sthe
sis
pros
thes
is o
ver d
entu
re
15° 25°
15° 25°
* *
* *
*
* *
* *
* *
TRANSFER ABuTMENT TRANSMUCOSALClOSED TRAy FOR PTCPTT-4012; PTT-5012.
TRANSFER ABuTMENTClOSED TRAy FOR PThCTFPThC-4013; TFPThC-5013.
TRANSFER ABuTMENTClOSED TRAy FOR PTPTFPTP-4013; TFPTP-5013.
TRANSFER ABuTMENT TRANSMUCOSALOPEN TRAy FOR PTCPTTA-4012; PTTA-5012.
TRANSFER ABuTMENTOPEN TRAy FOR PThCTAPThC-4013; TAPThC-5013.
TRANSFER ABuTMENTOPEN TRAy FOR PTPTAPTP-4013; TAPTP-5013.
STANDARD TRANSMUCOSALABuTMENT PROTECTI ONPPP-4004; PPP-5004.
PROTECTI ON FOR NON-ROTATIONAlTRANSMUCOSAL ABuTMENTSPPT-4004; PPT-5004.
PROTECTI ON FOR ThE TITANIUM TRANSMUCOSAL ABuTMENTSPPT-4004; PPT-5004.
ANAlOg OF ThE STANDARD TRANSMUCOSAL ABuTMENTPTPA-4010; PTPA-5010.
ANAlOg OF ThE NON-ROTATI ONAlTRANSMUCOSAL ABuTMENTPThCA-4012; PThCA-5012.
ANAlOg OF ThE TITANIuM TRANSMUCOSALABuTMENTPTCA-4012; PTCA-5012.
clinical laboratory
BuRNOuT NON-ROTATI ONAl ABuTMENT WITh CrCoMo EDgE OF ThE NON-ROTATIONAl TRANSMUCOSALPlETh-4015; PlETh-5015.
BuRNOuT ROTATIONAl ABuTMENT WITh CrCoMoEDgE OF ThE TRANSMUCOSALPlET-4015; PlET-5015.
BuRNOuT ABuTMENT OF THE TRANSMUCOSALPPET-4015; PPET-5015.
BuRNOuT NON-ROTATIONAl ABuTMENT OF ThE NON-ROTATIONAl TRANSMUCOSALPETh-4015; PETh-5015.
BuRNOuT ABuTMENT WITH CrCoMo EDGEOF ThE TRANSMuCOSAl STANDARDPElP-4015; PElP-5015.
BuRNOuT ABuTMENTOF ThE TRANSMuCOSAl STANDARDPEPP-4015; PEPP-5015.
10,0mm 11,5mm 13,0mm 14,5mm 16,0mm
Ø 2,5mm
Ø 3,0mm
2510 2511 2513 2514 2516
3010 3011 3013 3014 3016
cOLOSSO IMPLANTSuNIQuE BODY ABuTMENT
10,0mm 11,5mm 13,0mm 14,5mm 16,0mm
Ø 2,5mm
Ø 3,0mm
2510 2511 2513 2514 2516
3010 3011 3013 3014 3016
cOLOSSO IMPLANTSuNIQuE O´RINg EVOLuTION
TRANSFER ABuTMENT OF ThE COlOSSO IMPlANT uNIquE BODyPTCU-3512
TRANSFER ABuTMENT OF ThE COlOSSO IMPlANT uNIquE BODyPTCU-3512
ANAlOg OF ThE COlOSSO IMPlANT uNIquE BODy ABuTMENTACP-3018
ANAlOg OF ThE COlOSSO IMPlANT uNIquE BODy O-RINgACO-3018
70N.cm
Surgical maximum
torque
screwM2
product
SEE IN EMFIlS WEBSITE MANuAL OF PROcEDuRES
70N.cm
Surgical maximum
torque
screwM2
product
SEE IN EMFIlS WEBSITE MANuAL OF PROcEDuRES
With 2,0mm diameter this drill is used for accurately initiate the drilling of thesurgical cavity and break the resistance of the cortical bone. It features a pointed shape, similar to a spear that favors the stabilization during drilling start.
It features a cylindrical terminal portion of 5.0mm height without cutting edgeto provide stability to the partial cut of the next diameter. It has a laser marks corresponding to the length of 7.0 mm.
The first of the sequence defines the depth of cut, the others enlarge thediameter. They feature laser marks on their body indicating the lengths ofthe implants Colosso.
SPEAR DRILL
PILOT DRILL
hELIcAL DRILL
The drills available in System, aims to facilitate drilling. The drilling with increasing diameters generates less friction, hence less heat, giving the dentist more safety during surgery. More drills provide more options for drilling in surgery at no extra cost.
SEQuÊNcIA DE BROcAS DO SISTEMA cOLOSSO
A - Spear Drill 2,0mm (Installation of the Abutment Colosso Evolution or O´ring Colosso
Evolution 2.5mm diameter).
B - Pilot Drill 2.0/2.5mm
c - helical Drill 2.5mm (Installation of the Colosso Evolution Abutment or O´ring Colosso
Evolution 3.0mm diameter).
D - Pilot Drill 2.5/2.8mm
E - helical Drill 2.8mm (Installation of the Colosso IHE Evolution, Colosso ECI Evolution or
Colosso CRC Evolution 3.3mm diameter).
F - Pilot Drill 2.8/3.2mm
g - helical Drill 3.2mm (2.0mm at cortical for endosteal installation of the Colosso CRC
Evolution cervical portion).
h - helical Drill 3.5mm (Installation of the Colosso IHE Evolution, Colosso ECI Evolution or
Colosso CRC Evolution 4.0mm diameter).
I - helical Drill 3.8mm (2.0mm at cortical for endosteal installation of the Colosso CRC
Evolution cervical portion).
J - helical Drill 4.2mm
K - helical Drill 4.5mm (Installation of the Colosso IHE Evolution, Colosso ECI Evolution or
Colosso CRC Evolution 5.0mm diameter).
L - helical Drill 4.8mm (2.0mm at cortical for endosteal installation of the Colosso CRC
Evolution cervical portion).
BAlC-2020 BAhC-2520 BAhC-2820 BAhC-3220 BAhC-3520 BAhC-3820 BAhC-4220 BAhC-4520 BAhC-4820
BAPC-2511 BAPC-2811 BAPC-3211
NOTE: ON lOW DENSITy BONES (TyPE 4) ThE lAST DRIllS RElATED TO EACh DIAMETER ShAll BE uSED ONly ON ThE FIRST TWOThIRDS OF ThE ARITIFICAl SOCKET. ON hIgh DENSITy BONES (TyPE 1 AND 2) ThE NEXT DRIll ShAll BE uSED ON ThE INITIAl FIRST ThIRDOF ThE ARTIFICIAl SOCKET. * DRIllS TO BE uSED FOR TOTAl ENDOSTEAl CRCE INSTAllATION
3,3mm implants
4,0mm implants
5,0mm implants
2,5mm implants de 3,0mm implants
Drills
ICPE and ICOE implants
ECIE, CRCE and IHEE implants
VISIT ThE EMFILS wEBSITE AND wATch ThE OF IMPLANT SYSTEM hAND’S ON
SEE ThE uSE OF DRILLS IN IMPLANT SYSTEM hAND’S ON
SuRgICAl KIT COLOSSO EVOLUTIONECE-0504
SuRgIcAL ANDPROSThETIc INSTRuMENTS
The System Colosso Evoluti on off ers to Emfi ls customers an assembly that makes theOsteointegrable Implant System Colosso the most competi ti ve in the market.
Surgical and Prostheti c lets you install all three types of implants that comprise the System: External hexagon, hexagon and Internal Body only. Moreover, it is the only one who has only a 1.2 mm hex wrench, ti ghten all screws that have the same thread pitch patt ern M2.
With the tools essenti al for the implementati on of the fi rst surgical procedure, is accompanied by the Intermediate Short and long for the inserti on of implants single body, a metal case suitable for sterilizati on in an oven or autoclave and has universal Torque Tester, which allows measurements of 25 N. up to 75 cm N.cm. The instrumental support of the Surgical Kit is aluminum, accommodates and organizes all drills sequenti ally instrumental in identi fying niches with laser and protected by rings of silicon.
The Surgical Kit Colosso Evoluti on joins technical and scienti fi c knowledge with the alreadyknown versati lity and practi cability of the enti re system.
hEXAgONAl KEy 1.2CHCC-1210; CHLC-1220
It laser markings correspond to 2.0mm,4.0mm and 6.0mm height related to thecervical porti on of the implants Colosso,allowing they can be used at the heightselecti on of the prostheti c, surgical and labcomponents.
ONE KEY TIghTENSALL ThE SYSTEM’SScREwS
UNIVERSAL TORQUE TESTERTC-0504
SEE IN EMFIlS WEBSITE MANuAL OF PROcEDuRES
Its acti on inverter, indicated by arrows, isplaced on the cable end.It measures from 25 up to 75 N.cm, thusbeing prostheti c and surgical.
• SPEAR DRIll 2,0MM - BAlC-2020• PIlOT DRIll 2.0/2.5MM - BAPC-2511• hElICAl DRIll 2.5MM - BAhC-2520• PIlOT DRIll 2.5/2.8MM - BAPC-2811• hElICAl DRIll 2.8MM - BAhC-2820• PIlOT DRIll 2.8/3.2MM - BAPC-3211• hElICAl DRIll 3.2MM - BAhC-3220• hElICAl DRIll 3.5MM - BAhC-3520• hElICAl DRIll 3.8MM - BAhC-3820• hElICAl DRIll 4.2MM - BAhC-4220• hElICAl DRIll 4.5MM - BAhC-4520• hElICAl DRIll 4.8MM - BAhC-4820• BIDIgITAl KEy ShORT - CBCC-8310• BIDIgITAl KEy lONg - CBlC-8320
• TORquE TESTER WITh INVERTER AND ADP - TC-0504• hEXAgONAl KEy 1.2MM ShORT - CHCC-1210• hEXAgONAl KEy 1.2MM lONg - CHLC-1220• INTERMEDIATE 2.4MM ShORT - INCC-2415• INTERMEDIATE 2.4MM lONg - INLC-2420• INTERMEDIATE 2.0MM ShORT - INCC-2015• INTERMEDIATE 2.0MM lONg - INLC-2020• INTERMEDIATE ShORT uNIquE BODy IMPlANT - ICCU-3008• INTERMEDIATE lONg uNIquE BODy IMPlANT - ILCU-3013• PARAllElOMETER (2) - PRC-2223• DEPTh gAugE - PRC-2530• DRIll EXTENDER - PBC-3055• INSTRuMENT hOlDER - SIC-0504• SuRgICAl BOX - ECC-0504
CIRCULAR SCALPEL BCl-3320; BCl-4020; BCl-5020BCC-3310; BCC-4010; BCC-5010
* products sold separately from the Surgical Kit
BONE ChISEl COlOSSOESL-3320; ESL-4020; ESL-5020ESC-3310; ESC-4010; ESC-5010
SAFETy RINg KITKASB-0008
INTERMEDIATE 2.4MMCONTRA-ANglE ICCA-2420; ILCA-2425
INTERMEDIATE FOR INTERNAl HEXAGON 2,4 mmINCC-2415; INLC-2420
IINTERMEDIATE FOR EXTERNAl HEXAGON 2,0 mmINCC-2015; INLC-2020
While drilling they assure the intended depth for the arti fi cial socket making. fi xed on the drill by a screw with hexagon 1.2mm. Avaible in 8 diameters: 2,5mm; 2,8mm; 3,2mm; 3,5mm; 3,8mm; 4,2mm; 4,5mm e 4,8mm.
Available in two sizesShort and long for Colosso Implants Internal and Externalhexagon. It is used for exposing the implants withkerati nized gum over them.
Available in two sizes: Short and long they connect the contra-angle to the two body implants Colosso, so they may be installed by motor at a speed of approx. 30 turns/minute.
Available in two sizes:Short and long for Colosso Implants Internal and External hexagon.Intended to remove the bone that eventually may overlay the implant cover cap hindering its removal.
Available in two sizes:Short and long, they are connected to the two body implants Colosso and actuated by the bidigital key or torque testerproviding implant placement conti nuity.
Available in two sizes:Short and long, they are connected to the two body implants Colosso and actuated by the bidigital key or torque testerproviding implant placement conti nuity.
SAFETY IN ThE MAKINg OF ARTIFIcIAL ALVEOLAR
SuRgIcAL ANDPROSThETIc INSTRuMENTS
BONE KIT 4 IN 1KO - 2801P
• graft Kit Case;• hand-Driver;• Drills for short contra-angle,diameters:
1.1mm; 1.3mm and 1.6mm;• Drills for long contra-angle, diameters:
1.1mm; 1.3mm e 1.6mm;• Fixati on rod for the hand-driver screw;• Fixati on rod for the contra-angle screw;• 12 Fixati on screws: - 1,6 x 4,0mm - 2,0 x 4,0mm - 1,6 x 6,0mm - 2,0 x 6,0mm - 1,6 x 8,0mm - 2,0 x 8,0mm - 1,6 x 10,0mm - 2,0 x 10,0mm - 1,6 x 12,0mm - 2,0 x 12,0mm - 1,6 x 14,0mm - 2,0 x 14,0mm• Bone Expander with Thread: - Ø 2,0mm - Ø 2,5mm - Ø 3,0mm - Ø 3,5mm - Ø 4,0mm - Ø 4,5mm• Expander Point: - Ø 2,0mm - Ø 2,5mm - Ø 3,0mm - Ø 3,5mm - Ø 4,0mm - Ø 4,5mm• Compactor Point: - Ø 2,0mm - 3,0mm - Ø 2,8mm - 3,7mm - Ø 3,2mm - 4,2mm - Ø 4,0mm - 5,0mm• Surgical hammer.
CMKE-22106
BER-3011; BER-3013; BER-3016
BER-5411; BER-5413; BER-5416
CPCM-2771
CPCA-2728
PEO-1604 - PEO-2004PEO-1606 - PEO-2006 PEO-1608 - PEO-2008 PEO-1610 - PEO-2010PEO-1612 - PEO-2012PEO-1614 - PEO-2014
EXPR-2025 EXPR-2525 EXPR-3025 EXPR-3525 EXPR-4025 EXPR-4525
PEXP-2070 PEXP-2570 PEXP-3070 PEXP-3570 PEXP-4070 PEXP-4570
PCOM-2030 PCOM-2837 PCOM-3242 PCOM-4050MAR-1225
The Bone Kit 4 in 1 is designed to provide more practi cality to the denti st in complex procedures.
In one kit you rely on instrumental to graft bone compressor, expander expander bone and bone screw, which allows performing advanced procedures with a single kit.
Fully Autoclavable.
DEVELOPED FOR ADVANcED PROcEDuRES PRAcTIcE
gRAFT hAND-DRIVERCMKE-22106
SURGICAL HAMMERMAR-1225
used for capturing and fi xing the graft screws with Philips connecti on, the graft hand-Driver has ergonomic design for ease of use and safety procedures.It is also used as the cable ends of expanders and compressors.
ERgONOMIc DESIgNQuIcK hITch
It is made of stainless steel and contains a Tefl on shield that ensures the effi ciency of its use with minimal trauma to the procedure.It is opti onally used in compressors and expanders.
LESS TRAuMA IN PROcEDuRE
BONE COMPACTOR KITKCO-2807A9
BONE EXPANDER KIT WITH THREADKEOR-2807A9
BONE EXPANDER KITKEO-2807A9
• Made of stainless hardened steel;• With thread to facilitate the inserti on in areas diffi cult to reach;• used connected to the torque tester;• Acti ve parallel part in 6 diameters (2,0mm;
2,5mm; 3,0mm; 3,5mm; 4,0mm e 4,5mm);• laser marking of the diameter on the base of
each instrument and on the end with thread, indicati ng the depth;
• Supplied with Expander Kit Case;• Autoclavable.
• Made of stainless hardened steel;• Convex point;• It is used when the bone thickness is thin; the
bone expansion is carried out under pressure for the Colosso implant placement;
• Acti ve parallel part in 6 diameters (2mm; 2,5mm; 3mm; 3,5mm; 4,0mm e 4,5mm);
• Diameter marking on each instrument side;• Supplied with Expander Kit Case;• used with the hand-driver (CMKE); • Autoclavable.
• Made of stainless hardened steel;• Concave point; • used to lift up the maxillary sinus fl oor;• Acti ve tapered part in 4 diameters (2mm
- 3mm; 2,8mm - 3,7mm; 3,2mm - 4,2mm; 4mm - 5mm);
• Diameter marking on each instrument side;• Supplied with Compactor Kit Case;• used with hand-driver (CMKE); • Autoclavable.
BONE gRAFT KIT KE-1585
• graft Kit Case;• hand-Driver;• Drills for short contra-angle, diameters: 1,1mm; 1,3mm
e 1,6mm;• Drills for long contra-angle, diameters: 1,1mm; 1,3mm
e 1,6mm;• Fixati on rod for the hand-driver screw;• Fixati on rod for the contra-angle screw;• 12 Fixati on screws: 1,6 x 4,0mm - 2,0 x 4,0mm 1,6 x 6,0mm - 2,0 x 6,0mm 1,6 x 8,0mm - 2,0 x 8,0mm 1,6 x 10,0mm - 2,0 x 10,0mm 1,6 x 12,0mm - 2,0 x 12,0mm 1,6 x 14,0mm - 2,0 x 14,0mm• Autoclavable.
Resellers, products and Emfi ls services:
www.emfi ls.com
0800 772 8910+ 55 (11) 4813.8900+ 55 (21) 2421.1975+ 55 (11) 2628.1371+ 55 (19) 2511.6664+351 22 832 3845+511 625 9743
SACItu (Company)Rio de Janeiro
São PauloCampinas
PortugalPeru
Prod
uct C
atal
og 2
011.
Issu
e 1.
illu
stra
ti ve
imag
es. P
rodu
cts
may
cha
nge
with
out n
oti c
e.