English balton product training
-
Upload
lee-nguyen -
Category
Documents
-
view
284 -
download
9
description
Transcript of English balton product training
www.balton.pl
Balton is an innovative design and medical production company
10.000m2 of production area
400 employees
production rooms of the cleanness class C
Produces medical equipment for cardiology, radiology,
anaesthesiology, surgery, dialysis, urology and gynecology.
Balton has received ISO 9001 certificate, CE mark, patents and many
awards.
All products are of I, II a, II b and III medical grade.
Has own research and development facility with microbiological,
chemical and mechanical laboratories.
Cooperates with many scientific centres and clinics in Poland
and Europe as well as with companies from France, US,
Germany, Russia and Japan.
COMPANY OVERVIEW
COMPANY HISTORY
1980 – stainless steel guide wires for introducers 1982 – epidural catheters 1985 – needles for hemodialysis1987 – catheters for angiography 1988 – catheters for dialyses 1990 – embolectomy catheters 1993 – urologic catheters 1995 – catheters for vessel catheterization 1997 – concession for the production of medical equipment
– ISO 9001 Certificate – catheters with hydrophilic coating
1999 – EC Design-Examination Certificate2000 – catheter for peripheral angioplasty
– catheter for coronary angioplasty „FRYDERYK”2002 – peripheral „NEPTUN” and coronary„CHOPIN2” balloon expanding stents2003 – self-expanding peripheral stent „JAGUAR”2004 – stent for renal vessels „NEFRO”2005 – stent for trachea and esophagus „TOR”
– cobalt – chromium coronary stent „KOS”– paclitaxel eluting stent „LUC-CHOPIN2”
2006 – thermodilution catheters „BALKAT”2007 – PTCA guide wire „RIDER®”2009 – intra-aortic balloon catheter set2010 – catheter for coronary bifurcation angioplasty „BOTTLE®”
– coronary bifurcation stent system „BIOSS®”– coronary angioplasty catheter „RIVER®” – Neuroprotection system „Robin®”
2011 – paclitaxel eluting coronary bifurcation stent system „BIOSS Expert®”– paclitaxel eluting cobalt-chromium coronary stent system „Paxel®”– sirolimus eluting coronary bifurcation stent system „BIOSS LIM®”– coronary stent system „Flexus®” – sirolimus eluting coronary stent system „Prolim®”– sirolimus eluting coronary stent system „Carlo S®”– cobalt-chromium coronary stent system „Coflexus®”– sirolimus eluting cobalt-chromium coronary stent system „Alex®”
2013 – self-expanding carotid stent „MER” – SOON!– paclitaxel coated angioplasty balloon – SOON!– temporary bipolar pacing electrode – SOON!
Stent material steel 316 L
Stent design closed cell
Strut thickness 0.12 mm
Stent diameter 2.00 – 5.00 mm
Stent length 8 - 40 mm
MRI safe
Use with guide wire .014”
Use with guiding catheter 5F*
Length reduction after deployment <0.5%
Recoil <2%
Stent crimped profile .038”/0.97 mm**
Distal shaft diameter 2.7F/0.90 mm
Proximal shaft diameter 2F/0.65 mm
Nominal pressure/RBP 10 atm/16atm
Delivery system type Rapid Exchange
Delivery system length 140 cm
*for stent diameter 4.5 and 5.0 mm use guiding catheter 6F**for stent diameter 3mm
Events n=97
Death 0 (0%)
Emergent CABG 2 (1.9%)
TLR* 22 (22.6%)
Revascularization per patient 0.24
Cumulative MACE 24 (24.7%)
Late thrombosis 0 (0%)
STENT REGISTRY - CLINICAL OUTCOMES AFTER 6 MONTHS
*clinically driven
STENT REGISTRY – QCA AFTER 6 MONTHS F-UP
Baseline Afterimplantation
6 month f-up
RD (mm) 2.75 ± 0.61 3.05 ± 0.55 2.80 ± 0.59
MLD (mm) 1.31 ± 0.52 2.67 ± 0.58 2.32 ± 2.12
%DS 61.3 ± 25.9% 12.1 ± 10.9% 25.6 ± 19.0 %
AG/LL AG=1.35 mm LL=0.58 mm
Restenosis 13 (14.7%)
p=0.0001 p=0.18
World in year
At the same time, foresighting problems with biotolerance ofbiostable polymers in the blood environment, Balton createsWorld’s first coated with biodegradable polymer Drug ElutingStent with paclitaxel – Luc-Chopin2 . The idea of the coating andstent itself were presented on TCT 2005.Unlike some biostable coatings, Luc-Chopin2 coating is fullybioacceptable and biodegradable with no harm to human body
Drug Eluting Stents are capturing the world market. Polymer drug carrier in those stents is biostable/non-biodegadable polymer
Poland
2003
Based on clinical trial results of Drug Eluting Stents:In some cases DES coated with nondegradable coatings can cause late inflammatory response, late and very late thrombosis.
11
World: 2007
PLGACo-polymer
Physical Properties
Combination of polilactideand polyglicolyc polymers-Inert-flexible, ductable-thin, with high drugloading capacity
Manufacturability
High stabilityof the manufacture process
Controlled degradation time = controlled drug release
Mechanical integrity
Biocompatibility
Low thrombogenicityand inflamation
Strong adhesion to stent
PLGA degradates in 8 weeks releasing CO2 and H2O only
Stent surface after 1 week Stent surface after 8 weeks
Luc-Chopin2 stent and its outstanding performance (based on clinical trial results)was appriciated by the 12th International Local Drug Delivery MeetingConference Board with 1st Prize of Conference, Geneva, Swiss, 2006
13
Anti-proliferative agent paclitaxel (< 2µg/mm2)
Polymer Biodegradable
Stent diameter 2.00 – 5.00 mm
Stent length (mm) 8 – 40 mm
Stent platform stainless steel 316L
Strut thickness 0.12mm
Designclosed cell - for uniform drug distribution and coverage of the vessel wall
Ferromagnetism none
MRI safe
Use with guide wire max .014”
Use with guiding catheter 5F*
Length reduction after deployment <0.5%
Recoil <2%
Stent crimped profile .040” **
Distal shaft diameter 2.7F/0.90 mm
Proximal shaft diameter 2F/0.65 mm
Nominal pressure / RBP 10 atm / 16 atm
Delivery system length 140 cm
Delivery system type Rapid Exchange*for stent diameter 4.5 and 5.0 mm use guiding catheter 6F**for stent diameter 3mm
MACE after 12 months follow-up
7.8% 8.5% 9.7%
Despite that 47% of the treated lesionswere B2 and C type, MACE resultsafter 12 months in Luc-Chopin2
patientsare better than in comparable stents
B2B2AA
39.1
42.6
10.4
7.9
CC
B1B1
Type of lesions
Clinical trial results
CONCLUSIONS
Coronary stenting with a LUC-Chopin is safe, withvery low complication rate
Biodegradable polymer guarantee safety- there wereno late stent thrombosis
Late loss and MACE rate after 9 and 12 monthsfollow-up was low and comparable to other DESescurrently available on the market
…”Conceptually, use of biodegradable polymer whose duration on the stent surface matches the period of antirestenotic action of the drug may provide improved safety profile by reducing late events related to persistent presence of polymer on the surface of the first-generation stents. It may consequently also shorten the obligatory period of double antiplatelet therapy, enhancing overall clinical and economical benefit”…
Meeting the medical market requirements: Balton creates Cobalt-Chromium stent KOS
Safety & Efficacy registry launches on KOS project
January 2006 – KOS Clinical Trial final report
Safety and efficacy of Balton’s Cobalt-Chromium stent KOShas been proven
18
Year 2005
CORONARY STENT
Advantages of KOS stents
•High radial strength•Enhanced visibility•Low profile with good flexibility and curve conformity •Safety and biocompatibility
*for stent diameter: 3mm
Stent material cobalt-chromium alloy L605
Stent nominal diameters 2.00 mm – 5.00 mm
Stent nominal lengths 8 mm – 40 mm
Wall thickness 0.080 mm
X-ray visibility Very good
Ferromagnetism none
MRI safe
Use with guide wire max. .014”
Use with guiding catheter 5F
Radial force high
Trackability and manouverability excellent
Stent crimped profile .036”
Distal shaft diameter 2F / 0.65 mm
Proximal shaft diameter 2.7F / 0.90 mm
Nominal pressure / RBP 10 atm / 16 atm
Delivery system type Rapid Exchange
Delivery system length 140 cm
20
®
small profile
0.036”
Stent material 316L stainless steel
Stent nominal diameters 2.00 mm – 5.00 mm
Stent nominal lengths 8 mm – 40 mm
Wall thickness 0.115 mm
X-ray visibility very good
Ferromagnetism none
MRI safe
Use with guide wire max. .014”
Use with guiding catheter 5F
Radial force high
Trackability and manuverability excellent
Stent crimped profile .036”
Proximal shaft diameter 1,8F / 0.60 mm
Distal shaft diameter 2.5F / 0.84 mm
Nominal pressure / RBP 8 atm / 16 atm
Delivery system type Rapid Exchange
Delivery system length 140 cm
®
Sirulimus eluting coronary stent
®
small profile
0.038”BIODEGRADABLE
POLYMER
Anti-proliferative agent Sirolimus
Polymer biodegradable
Paltform Flexus
Material 316L stainless steel
Stent diameter 2.00 mm – 5.00 mm
Stent length (mm) 8 mm – 40 mm
Strut thickness 0,115 mm
Ferromagnetism none
MRI safe
Use with guide wire max. .014”
Use with guiding catheter 5F
Length reduction after deployment <0.5%
Recoil Less than 2%
Crimped Stent profile .038”
Proximal shaft diameter 1.8F / 0.60 mm
Distal shaft diameter 2.5F / 0.84 mm
Nominal pressure / RBP 8 atm / 16 atm
Delivery system type Rapide Exchange
Delivery system length 140 cm
®
®
Anti-proliferative agent Sirolimus
Polymer biodegradable
Platform Chopin 2
Material 316L stainless steel
Stent diameter 2.00 mm – 5.00 mm
Stent length (mm) 8 mm – 40 mm
Stent platform 316LVM stainless steel
Strut thickness 0,12 mm
Ferromagnetism none
MRI safe
Use with guide wire max. .014”
Use with guiding catheter 5F
Crimped Stent profile .040”
Proximal shaft diameter 2,0F / 0.65 mm
Distal shaft diameter 2.7F / 0.90 mm
Nominal pressure / RBP 10 atm / 16 atm
Delivery system type Rapide Exchange
Delivery system length 140 cm
®
very small profile
0.032”
Stent material cobalt-chromium alloy L605
Stent nominal diameters 2.00 mm – 5.00 mm
Stent nominal lengths 8 mm – 40 mm
Wall thickness 0.070 mm
X-ray visibility Very good
Ferromagnetism none
MRI safe
Use with guide wire max. .014”
Use with guiding catheter 5F
Radial force high
Trackability and manouverability excellent
Stent crimped profile .032”
Proximal shaft diameter 1,8F / 0.60 mm
Distal shaft diameter 2.5F / 0.84 mm
Nominal pressure / RBP 8 atm / 16 atm
Delivery system type Rapid Exchange
Delivery system length 140 cm
®
®
very small profile
0.034”
BIODEGRADABLE POLYMER
Stent material cobalt-chromium alloy L605
Polymer biodegradable
Anti-proliferative agent Paclitaxel
Platform Coflexus
Stent nominal diameters 2.00 mm – 5.00 mm
Stent nominal lengths 8 mm – 40 mm
Wall thickness 0.070 mm
X-ray visibility very good
Ferromagnetism none
MRI safe
Use with guide wire max. .014”
Use with guiding catheter 5F
Radial force high
Trackability and manouverability excellent
Stent crimped profile .034”
Proximal shaft diameter 1,8F / 0.60 mm
Distal shaft diameter 2.5F / 0.84 mm
Nominal pressure / RBP 8 atm / 16 atm
Delivery system type Rapid Exchange
Delivery system length 140 cm
®
®
very small profile
0.034”BIODEGRADABLE
POLYMER
Stent material cobalt-chromium alloy L605
Polymer biodegradable
Anti-proliferative agent Sirolimus
Platform Coflexus
Stent nominal diameters 2.00 mm – 5.00 mm
Stent nominal lengths 8 mm – 40 mm
Wall thickness 0.070 mm
X-ray visibility Very good
Ferromagnetism none
MRI safe
Use with guide wire max. .014”
Use with guiding catheter 5F
Radial force high
Trackability and manouverability excellent
Stent crimped profile .034”
Proximal shaft diameter 1,8F / 0.60 mm
Distal shaft diameter 2.5F / 0.84 mm
Nominal pressure / RBP 8 atm / 16 atm
Delivery system type Rapid Exchange
Delivery system length 140 cm
®
®
®
®
®
®
®
Bioss stent is a innovative and technologically advanced solution for bifurcations treatment
EASY IMPLANTATION
•Unique configuration of the delivery system ensures safety and efficacy during the Bioss stent
implatation procedure
• Worlds’ first dedicated for bifurcation delivery system guided on single guide wire
• One special balloon with two diameters corrensponding to main vessel and main branch diameters
Bioss international patent pending
PROXIMAL SEGMENTDISTAL SEGMENT
LARGE STENT CELL
PROXIMALDIAMETER
DISTAL DIAMETER
International patent pending
IMPORTANT: mid marker shall be placed in linewith carina tip
You will earn:-Anatomically fitted stent which correspondwith physiological vessel diameters- Not disturbed SB blood flow-Easy access to SB through large stent cell
Bioss international patent pending
Mid –marker of the delivery system
®
Stent total length[mm]
Proximal diameter[mm]
Distaldiameter
[mm]
15.00
4.50 3.754.25 3.503.75 3.003.50 3.003.50 2.753.25 2.50
18.00
4.50 3.754.25 3.503.75 3.003.50 3.003.50 2.753.25 2.50
23.00
4.50 3.754.25 3.503.75 3.003.50 3.003.50 2.753.25 2.50
International patent pending
® ® ®
Large cell of the stent in place of side branch entrance gives possibility to enter the SB with any standard size conventional stent
Implant construction allows Bioss stent adjust to vessel curvature
Precise implantation of Bioss family stents against carina tip is ensured by three radiopaque markers
Front view
Lateral view
®
ANGIOPLASTY BALLOON CATHETER FOR BIFURCATION LESIONS
Angioplasty balloon catheter Bottle is design for:1. Bifurcation optimization after deplyment of classic stent2. Angioplasty of bifurcation coronary stenosis
®
ANGIOPLASTY BALLOON CATHETER FOR BIFURCATION
®
5F
Balloon diameter 1.25 – 5.0 mm
Balloon length 10 - 40 mm
Use with guiding catheter
For balloon diameter 1.5 – 4.0mm 5F
Use with guidingcatheter
For balloon diameter 4.5 – 5.0mm 6F
Crossing profile 0.026”
Nominal pressure 10 atm
Rated Burst Pressure
RBP16 atm
Catheter length 140 cm
Delivery system type RX
CORONARY ANGIOPLASTY CATHETERCORONARY ANGIOPLASTY CATHETER
• a low-profile angioplasty balloon catheter dedicated for narrow and tortus vessel
• high flexibility
• excellent pushability and manouverability
®
diameters 1,25 – 4,0 mm
lenghts 10 - 40 mm
Material nylon
Catheter coating Hydrophilic
Entry profile 0.017” (0,43 mm)
Crossing profile 0.025” (0,63 mm)
Proximal diameter 1.8F (0,60 mm)
Dital catheter part diameter 2.5F (0.84 mm)
Pushability and manouverability excellent
Inflation / deflation time Very short
Guide wire max. 0.014”
Minimal guiding catheter OD/ID 5F / 0.056”
Nominal pressure 8 atm
RBP 16 atm
Catheter lenght 140 cm
Delivery system type Rapid Exchange
®
Sample
Max Force for insertion
through 90°(grams)
Max Force for retraction
through 90°(grams)
Balton 8.71 -17.48Maverick 11.90 -20.79Sprinter 11.61 -22.47
Standarized FDA pushability test
®
River Maverick Sprinter
CatalogueNo.
Filtering basket diameter
[mm]
Recommendedfor vesseldiameter
Guide wirelength[cm]
SDN4RX 4 .014” 170
SDN5RX 5 .014” 170
SDN6RX 6 .014” 170
SDN7RX 7 .014” 170
SDN8RX 8 .014” 170
Rapid Exchange
CatalogueNo.
Filtering basket diameter
[mm]
Recommendedfor vesseldiameter
Guide wirelength[cm]
SDN4OTW 4 .014” 300
SDN5OTW 5 .014” 300
SDN6OTW 6 .014” 300
SDN7OTW 7 .014” 300
SDN8OTW 8 .014” 300
Over the wire
Two delivery & capture system types
Filtering basket made of biocompatible materials;
filter holes diameter: 100÷120 µm
PTFE .014” guide wire integrated with filtering basket
Atraumatic, flxible end-tip of the guide wirefacilitates safe reaching of the area beyond lesion
outstanding X-ray visibility
®
PERIPHERAL STENTSPERIPHERAL STENTS
Stent for renal arteries with RX delivery system
Material 316 stainless steel
Guide wire max .014”
Guiding catheter 6F
Nominal pressure 8 atm
Rated burst pressure 12 atm
Available diameters 5.0 – 7.0mm
Lengths 8.0 – 22.0mm
Delivery system type Rapid Exchange
World’s first renal stent with Rapid Exchange delivery system
Year 2004
Stent diameter 4 - 10 mm
Stent length 16 - 100 mm
Use with guide wire
.035”
Use with introducer
for stent diameter 4 – 6 mm 6F
Use with introducer
for stent diameter 7 – 9 mm 7F
Use with introducer
for stent diameter 10 mm 8F
Nominal Pressure 6 atm
Rated Burst Pressure
10 atm
Catheter length 80 or 110 cm
Delivery system type
OTW
STENT FOR PERIPHERAL VESSELSWITH DELIVERY SYSTEM
Curiosity:
NITINOL – discovered during research. at the U.S. Naval Ordnance Laboratory in 1962.
The new concept of self-expandable stent:Simple in design - simple in usePossibility of reposition effects in best efficecy for patients
• Constructed from Nitinol wire (NiTi) – material with higher biocompatibility leveland corrosion resistance than medical AISI 316L stainless steel
• Made in one-wire technology, without any welds and solders
• Special construction of the delivery system make to correction of stent position inside a vessel possible even after the partial stent release
• Elevated ends of the stent eliminating „fish mouth” effect and stent migration
• High radial force
• High flexibility of the JaguarSM stent effects in excellent adaptation to vessel curvature
Year 2003
48
SELF EXPANDING NITINOL STENT WITH DELIVERY SYSTEM
SELF EXPANDING NITINOL STENT WITH DELIVERY SYSTEM
The JaguarSM self-expanding stent with a delivery system isrecommended for percutaneous intravascular deployment inpatients with atherosclerotic, radiation and trauma-inducedstenoses.
The soft and rounded tip of delivery system is atraumatic towardsthe arterial wall.
Nominal stent diameters 4 – 14 mm
Nominal stent lengths 15 – 150 mm
Available delivery system length 80 or 135 or 165 cm
Guide wire and stent diameters for delivery system 6F.018”
4 – 10 mm.035”
Guide wire and stent diameters for delivery system 7F .035” 6 – 10 mm
Guide wire and stent diameters for delivery system 8F .035” 12 - 14 mm
Delivery system type OTW
PERIPHERAL ANGIOPLASTY CATHETER PBAPERIPHERAL ANGIOPLASTY CATHETER PBA
Balloon diameter 4 - 12 mm
Balloon length 20 - 100 mm
Use with introducer For balloon diameter 4 – 7 mm 6F
Use with introducer For balloon diameter 8 – 10 mm 7F
Use with introducer For balloon diameter 12 mm 8F
Nominal pressure 6 atm
Rated Burst Pressure
RBP10 atm
Catheter length 80 or 110 cm
Type of delivery system
OTW
They feature high functional parameters quality:- Thin walls, allowing maximum flow.- High pressure resistant 100 atm (1450PSI).- Relevant softness, flexibility and curvature, facilitating catheter introduction
and advancement.- Good visibility in X-rays.- Perfectly smooth surface and very good finishing of side holes.- Atraumatic tip.
Each catheters features a Luer-Lock connector, making the set hermetic.Some catheters size 5F and 6F are available in reinforced configuration with
stainless steel braided.All catheters feature the same softness in distal parts (unbraided).
CATHETERS FOR ANGIOGRAPHYCATHETERS FOR ANGIOGRAPHY
Cataloque No.
Balloonnominaldiameter
[mm]
Balloonnominal
lengtht [mm]
Catheterlenght
VALP5x2070 5 20 70 cm
VALP8x2070 8 20 70 cm
VALP10x4070 10 40 70 cm
VALP12x4070 12 40 70 cm
VALP15x2570 15 25 70 cm
VALP15x4070 15 40 70 cm
Cataloque No.
Balloonnominaldiameter
[mm]
Balloonnominallengtht[mm]
Catheterlenght
VAL15x40110 15 40 110 cm
VAL18x40110 18 40 110 cm
VAL20x45110 20 45 110 cm
VAL23x45110 23 45 110 cm
VAL25x50110 25 50 110 cm
VAL28x60110 28 60 110 cm
VAL30x60110 30 60 110 cm
VAL35x60110 35 60 110 cm
VAL40x60110 40 60 110 cm
Balloon with a soft tip at the distal end of the double lumen catheter – for easy introductionthrough the femoral artery
Catheter with a X-Ray visible markers - for precise determination of the balloon location
Sets compatible with DataScope and Arrow pumps
Balloon volume 20 – 50 ml
Balloon length 170 – 260 mm
Balloon diameter volume and lenght dependent
Shaft size 7F or 7.5F or 8F
Guide wire diameter .025”
IABC Insertion length 765 mm
Catalogue
No.
Sheath
Size / lengthCup colour Dilatator size
Angiographic
needle size
Guide wire
Size / length / type
INT3F 3F / 60 mm white 3F 21G .018” / 35 cm / STRAIGHT
INT4F 4F / 70 mm red 4F 19G .022” / 40 cm / “J”
INT5F 5F / 110 mm gray 5F 18G .035” / 40 cm / “J”
INT6F 6F / 110 mm green 6F 18G .035” / 40 cm / “J”
INT7F 7F / 110 mm orange 7F 18G .035” / 40 cm / “J”
INT8F 8F / 110 mm blue 8F 18G .035” / 40 cm / “J”
INT9F 9F / 110 mm black 9F 18G .035” / 40 cm / “J”
INT10F 10F / 110 mm white 10F 18G .035” / 40 cm / “J”
INT12F blue blue 12F 18G .035” / 40 cm / “J”
INT14F 14F / 110 mm blue 14F 18G .035” / 40 cm / “J”
INT16F 16F / 110 mm blue 16F 18G .035” / 40 cm / “J”
Set contains
sheath with valve angiographic needle guide wire dilator
Special order can contain braided introducer with radiopaque markerModel reference number:INT8FM – introducer with a markerINT6FT – braided introducer
Catalogue
No.
Sheath
Size / lengthCup colour
Dilatator
size
Angiographic
needle size
Guide wire
Size / length / type
INT3FK 3F / 60 mm white 3F 21G.018” / 35 cm /
PROSTY
INT4FK 4F / 70 mm red 4F 19G .022” / 40 cm / “J”
INT5FK 5F / 110 mm gray 5F 18G .035” / 40 cm / “J”
INT5FK23 5F / 230 mm gray 5F 18G .035” / 60 cm / “J”
INT6FK 6F / 110 mm green 6F 18G .035” / 40 cm / “J”
INT6FK23 6F / 230 mm green 6F 18G .035” / 60 cm / “J”
INT7FK 7F / 110 mm porange 7F 18G .035” / 40 cm / “J”
INT7FK23 7F / 230 mm porange 7F 18G .035” / 60 cm / “J”
INT8FK 8F / 110 mm blue 8F 18G .035” / 40 cm / “J”
INT8FK23 8F / 230 mm blue 8F 18G .035” / 60 cm / “J”
INT9FK 9F / 110 mm black 9F 18G .035” / 40 cm / “J”
INT10FK 10F / 110 mm white 10F 18G .035” / 40 cm / “J”
Set contains
sheath with valve angiographic needle guide wire dilator
Special order can contain braided introducer with radiopaque markerModel reference number:INT8FKM – introducer with a markerINT6FKT – braided introducer
Guide wire of special construction:•Soft, distal part of guide wire - enablesto reduce it to the vessel•Stiff, proximal part – provide an excellent scaffold for dilator along withpreventing from vessel perforation
Distal part of the sheath and of dilator is finished in the way thatenables easy and atraumaticintroduction of the catheter to thevessel
Catalogue
No.
Sheath
Size / lengthCup colour
Dilatator
size
Angiographic
needle size
Guide wire
Size / length / type
INT5FKR 5F / 110 mm gray 5F 21G .018” / 45 cm / “J”
INT5FKRP 5F / 110 mm gray 5f 21G .018” / 45 cm / straight
INT5F21KR 5F / 110 mm gray 5F 21G .021” / 45 cm / “J”
INT5F21KRP 5F / 110 mm gray 5F 21G .021” / 45 cm / straight
INT5FKR23 5F / 230 mm gray 5F 21G .018” / 50 cm / “J”
INT5FKR23P 5F / 230 mm gray 5f 21G .018” / 50 cm /straight
INT5F21KR23 5F / 230 mm gray 5F 21G .021” / 50 cm / “J”
NT5F21KR23P 5F / 230 mm gray 5F 21G .021” / 50 cm / straight
INT6FKR 6F / 110 mm green 6F 21G .018” / 45 cm / “J”
INT6FKRP 6F / 110 mm green 6F 21G .018” / 45 cm / straight
INT6F21KR 6F / 110 mm green 6F 21G .021” / 45 cm / “J”
INT6F21KRP 6F / 110 mm green 6F 21G .021” / 45 cm / straight
INT6FKR23 6F / 230 mm green 6F 21G .018” / 50 cm / “J”
INT6FKR23P 6F / 230 mm green 6F 21G .018” / 50 cm /straight
INT6F21KR23 6F / 230 mm green 6F 21G .021” / 50 cm / “J”
NT6F21KR23P 6F / 230 mm green 6F 21G .021” / 50 cm / straight
INT7FKR 7F / 110 mm orange 7F 21G .018” / 45 cm / “J”
INT7FKRP 7F / 110 mm orange 7F 21G .018” / 45 cm / straight
INT7F21KR 7F / 110 mm orange 7F 21G .021” / 45 cm / “J”
INT7F21KRP 7F / 110 mm orange 7F 21G .021” / 45 cm / straight
INT7FKR23 7F / 230 mm orange 7F 21G .018” / 50 cm / “J”
INT7FKR23P 7F / 230 mm orange 7F 21G .018” / 50 cm /straight
INT7F21KR23 7F / 230 mm orange 7F 21G .021” / 50 cm / “J”
NT7F21KR23P 7F / 230 mm orange 7F 21G .021” / 50 cm / straight
RADIAL ARTERY INTRODUCERSFOR CARDIOLOGY
GUIDEWIRESGUIDEWIRES
For interventional cardiology & radiologyThe tip of the guidewire is appropriately shaped andatraumatic for optimal patient's security Designed for complex vascular interventions including"cross-over" techniques.
Guidewires Size
Steel guidewires .022”, .035”, .038”
Hydrophilic guidewires .032”, .035”, .038”
Micro guidewires .007”, .009”, .014”
Lunderquist guidewires .035”
PTFE coated guidewires .018”, .022”, .025”, .035”, .038”
PTCA guidewire „Rider” .014”
PTCA GUIDE WIRES „RIDER” WITH HYDROPHILIC COATINGPTCA GUIDE WIRES „RIDER” WITH HYDROPHILIC COATING
• Material: steel and platinum• Length 175 -300 cm• Broad range of stiffness• Radiopaque marker of min. 25 mm length• Straight and "J" shaped guide wire tips• Excellent steerability• Special coating for optimal crossing of tortuous and narrow vessels• Stiff proximal shaft• Good visibility of guide wire tip• Optimal torque control 1:1
The guide wires are available in several kinds of flexibility of the distal tip:• with high floppy tip – HF• with floppy tip - F, • with medium tip - M, • with stiff tip – S• with high stiff tip – HS
Guide wires are available with additional strengthening in their proximal spiral part, which enables them for the delivery of stents:• stent support floppy – STF• stent support medium – STM• stent support stiff – STS.
Guidewire Size Length Type
PTCAguidewires
.014” 175 – 300 cm„J”
Straight
Large vessel catheterization set with:- Single lumen catheter- Double lumen catheter- Triple lumen catheter- Four lumen catheter
Anaesthesia sets
Spinal anaesthesia needles
Thermodilution set “BALKAT”
ENDOSCOPIC BALLOON DILATION CATHETER
FOR ESOPHAGEAL, PYLORIC AND COLONIC
ONE BALLOON – THREE DIFFERENT DIAMETERS AT THREE SEPARATE PRESSURES
•Compatible channel of endoscope 2.8 mm or larger
•Very good visibility in fluoroscopy
•Very short deflation time
•Usable with 60 ml inflation device (available in Balton product range)
•Guide wire type catheters are intended to be use with specially designed
PTFE coated Balton guide wires - ensures safety and easy use of the
endoscopic balloon catheter
ENDOSCOPIC BALLOON DILATION CATHETER
Ensures safety and easy use of the endoscopic balloon catheter
Appropriate 60 ml pressure inflator for Troyca catheters can be found in our portfolio
SPECIALLY DESIGNED PTFE GUIDE WIRES FOR TROYCA CATHETERS
Embolectomy catheters
Aortic catheters
Catheter for bile duct’s
Drains
- Nephrostomy sets
Nephrostomy & cystostomy set
- Cystostomy sets
- Ureteral catheters
- Sets for stent introduction
Insemination catheters
Histerosalpingography sets
HSG catheters
Accessories
Rotating „Y”
Manifolds
Torquers
Stopcocks
Connectors
High pressure inflators
Syringe volume: 20 mlMax. pressure: 30 atm
Syringe volume: 25 mlMax. pressure :30 atm
Syringe volume: 30 mlMax. pressure: 30 atm
Syringe volume: 60 mlMax. pressure: 15 atm