1

TABLE OF CONTENTSTABLE OF CONTENTSIntroduction .......................................................................................... 2-8

Closet Carriers .................................................................................... 9-38

Fixture Carriers ................................................................................ 39-59

Jiffee-Joint Gaskets................................................................................ 60

Roof Drains ...................................................................................... 61-97

Floor Drains .................................................................................... 98-146

Stainless Steel Products................................................................ 147-158

Sanitary Floor Sinks ...................................................................... 159-184

Cleanouts ...................................................................................... 185-204

Interceptors....................................................................................205-232

Backwater Valves ..........................................................................233-239

Hydrants........................................................................................ 240-248

Shock Absorbers ............................................................................249-252

Trench Drains ................................................................................ 253-256

Miscellaneous, Traps & Accessories .............................................. 257-266

PVC Products ................................................................................ 267-272

JOSAM COMPANY Phone: 800-365-6726P.O. Box T Fax: 800-627-0008Michigan City, IN 46361 www.Josam.com

©2008 JOSAM COMPANY All rights reserved. Printed in U.S.A.The name Josam and the Josam logo are trademarks of Josam Company. Products in this guide are covered by patents or patents pending.

TOC Index Intro.qxd 3/28/08 1:26 PM Page 1

WARNING: Cancer and Reproductive Harm - www.p65warnings.ca.gov

2

INSTRUCTIONS FOR USEINSTRUCTIONS FOR USE

AFFILIATIONS:JOSAM is a member of the Plumbing and Drainage Institute (PDI),The American Society of Plumbing Engineers (ASPE) and theAmerican Society of Sanitary Engineering (ASSE) and fully supportsthe aims and goals of these organizations.

AMERICAN NATIONAL STANDARDS INSTITUTE STANDARDS (ANSI)AMERICAN SOCIETY OF SANITARY ENGINEERING STANDARDS (ASSE)

PLUMBING AND DRAINAGE INSTITUTE STANDARDS (PDI)

JOSAM Products meet or exceed the following standards.

ANSI STANDARDS NO. ASSE STANDARDS NO. PDI STANDARDS NO. JOSAM PRODUCTSANSI A112.6.1M CARRIERSANSI A112.14.1 BACKWATER VALVESANSI A112.6.3 FLOOR DRAINSANSI A112.21.2M ROOF DRAINSANSI A112.21.3M HYDRANTSANSI A112.26.1M 1010 WH-201 SHOCK ABSORBERSANSI A112.36.2M CLEANOUTSANSI/ASSE 1018, 1044 TRAP SEAL PRIMER VALVESANSI/ASME A112.14.3 G-101 GREASE INTERCEPTORSANSI/ASME A112.14.4 GREASE RECOVERY DEVICES

This catalog has been designed to simplify the selection of drainage products. Products are grouped by size, shape and function. Base prod-ucts are shaded and include an application, specification, dimensional drawing and available options. An inverted triangle t to the left ofthe option indicates that the product with that option is depicted with an application, specification and dimensional drawing. Base prod-uct options apply to optional products unless noted under “Options N/A.” Photos of each product and its illustrated variations appear in aPictorial Selection Guide in the introduction of each product section. All designs, descriptions and dimensions are subject to change with-out notice, and unless specifically stated otherwise, standard products in effect at the time the order is shipped will be supplied. All weightsnoted are approximate and are not guaranteed.

APPLICATIONUsed on roofs of any size, typically concrete decking, large slotted dome ensuresmaximum free area for quick drainage of rainwater and protects the drain sumpand connected piping from debris. WEJLOC® compression-flashing clamp holds themembrane or flashing securely to the drain body. Extra wide flange provides posi-tive support and large bonding surface for liquid applied membranes.

SPECIFICATIONJOSAM 21500-6 Series coated cast iron Roof Drain, large polypropylene lockingdome. WEJLOC® non-puncturing clamp ring, large sump with extra-wide roof flangeand bottom outlet inside caulk connection.

OPTIONS N/A:-2, -4

APPLICATIONUsed on roofs of any size, for any type of construction. Large slotted dome providesmaximum free area for quick drainage of rainwater and protects the drain sump andconnected piping from debris. WEJLOC® compression flashing clamp holds the mem-brane or flashing securely to the drain body.

SPECIFICATIONJOSAM 21500 Series coated cast iron Roof Drain, large polypropylene locking dome,WEJLOC® non-puncturing clamp ring with integral gravel stop, large sump with wideroof flange and bottom outlet.

Available Optionst -AE LEVELEZE® Adjustable Ext.t -AER Adjustable Extension Using

Threaded Rodst -IRMA Perforated Stainless

Steel Extension-CR Clamping Drain Receiver-1 Deck Clamp Assembly-1C Drain Receiver Clips (Min.

Deck Opening 16.5" Dia.)-2 Drain Receiver-3 Deck Clamp Assembly and

Drain Receiver-3C Drain Receiver and

Drain Receiver Clips-4 Secondary Flashing Clamp

(use with -AE only)t -6 Extra Wide Flange Drain

Body, 2"- 6"-X only-10 Fixed Ext. Collar, C.I., (Specify

Hgt.) 4"Std.-10-20 Fixed Ext. Collar, Galv.,

(Specify Hgt.) 4"Std.

t -16 * Internal Waterguard 2"- 6" Outlets Only

-17 * 2" High Solid Clamping Collar

t -19 Clamp Collar w/Perforated SS Gravel Guard

-20 Galv. Cast Iron Parts-21 Galv. Cast Iron Dome Only-22 Cast Iron Dome-23 Rough Bronze Dome-26 Aluminum Dome-33 Stainless Mesh

Screen-Covered Dome-VP Vandal-Proof Dome

OUTLETS:-66 No-Hub Side Outlet, 2"-6"-T Threaded Outlet-X Inside Caulk Outlet-Y Hub Outlet w/Gasket, 2"-4"-Z No-Hub Spigot Outlet

*-16 and -17 cannot be furnished together.

ROOF DRAINSROOF DRAINS

74

21500 SERIES LARGE SUMP

21500-6 SERIES LARGE SUMP with -6 Extra Wide Flange Drain Body

CONFORMS WITH ASTM-C564.• THIS DIM. IS 5-3/4" FOR 21508-T.

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.21502 2 36 21506 6 4021503 3 37 21508 8 4221504 4 38 21509-Z 10† 4321505 5 39 †10” AVAILABLE IN NO-HUB ONLY.

FOR OUTLET TYPE SPECIFY -XTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.21502-6 2 77 21505-6 5 8021503-6 3 78 21506-6 6 8121504-6 4 79

t Product Illustration follows.

PRODUCT SECTION APPLICATION SPECIFICATION

DESCRIPTION

DIMENSIONAL DRAWING

OUTLET TYPES AVAILABLE

DIMENSION &WEIGHT CHART

DIMENSIONAL DRAWING

OUTLET TYPES AVAILABLE

SERIES NUMBER

AVAILABLE OPTIONS

AVAILABLE OUTLETS

SERIES NUMBER WITH OPTION

APPLICATION

SPECIFICATION

OPTIONS NOT AVAILABLE

DIMENSION &WEIGHT CHART

OPTION DESCRIPTION

BASE PRODUCT SHADED

TOC Index Intro.qxd 5/7/08 9:56 AM Page 2

3

JJuusstt aa FFeeww ooff TThhee MMaannyy FFeeaattuurreess AAvvaaiillaabbllee aattww ww ww..jjoossaamm..ccoomm

•• Easy Navigation

•• Instant List Pricing

•• Representative Directory

•• Company News, Events and Literature Updates

•• Downloadable Brochures and Catalogs

•• Various Search Options, Including Search byProduct Type, Application or Competitor'sPart Number

•• Submittal Drawing List

•• Expedite Orders

•• Obtain CAD or PDF Drawings

•• Spare Parts List

.com.com

Example of frequentlyupdated items

TOC Index Intro.qxd 4/9/08 9:06 AM Page 3

NUMERICAL INDEXNUMERICAL INDEX

4

SERIES NO. PAGE SERIES NO. PAGE SERIES NO. PAGE SERIES NO. PAGE

1100011001................................................ 2311007 ................................................ 2311008 ................................................ 23

1200012000-OR .......................................... 1512000-PF...................................... 14, 1712000-32 .................................... 16, 1712000-35 .................................... 21, 2212674 ................................................ 2412674-HS .......................................... 2512674-58 .......................................... 2512684 ................................................ 2412684-HS .......................................... 2512684-58 .......................................... 2512694 ................................................ 2412694-HS .......................................... 2512694-58 .......................................... 2512704 ................................................ 2612704-D4.......................................... 2712704-HS.......................................... 2612704-HS-HD4.................................. 2712704-HS-HLH4................................ 2712704-HS-HRH4 ................................ 2712704-LH4 ........................................ 2612704-RH4........................................ 2712714 ................................................ 2812714-D4.......................................... 2912714-HS.......................................... 2812714-HS-HD4.................................. 2912714-HS-HLH4................................ 2912714-HS-HRH4 .............................. 2912714-LH4 ........................................ 2912714-RH4........................................ 2812724 ................................................ 3012724-D4.......................................... 3112724-HS.......................................... 3112724-HS-HD4.................................. 3112724-HS-HVS4 ................................ 3112724-OS4 ........................................ 3112724-VS4 ........................................ 31

1400014004 ................................................ 3214024 ................................................ 3214044 ................................................ 3214064 ................................................ 3314104 ................................................ 3314404 ................................................ 3414424 ................................................ 3414444 ................................................ 3414464 ................................................ 3514484 ................................................ 3514504 ................................................ 36

1500015964 ................................................ 3715984 ................................................ 37

1600016123 ................................................ 38

1700017000 ................................................ 4517100 ................................................ 4617100-BB.......................................... 4617120 ................................................ 4617120-10 .......................................... 4717120-BP .......................................... 4717120-MMB ...................................... 4717125 ................................................ 4817380 ................................................ 4817380-BB .......................................... 4917380-HD .......................................... 4917380-BB-HD .................................... 4917390 ................................................ 5017390-BP .......................................... 5017405 ................................................ 5117550 ................................................ 5217550-BB .......................................... 5217550-CL............................................ 5317550-UR .......................................... 5217550-WC.......................................... 5317550-WCBL...................................... 5317560 ................................................ 5417560-BB .......................................... 5417560-UR .......................................... 5517560-WC.......................................... 5517560-WCBL...................................... 5517590 ................................................ 5617590-DP .......................................... 5617590-UR .......................................... 5717590-UR-DP .................................... 5717720 ................................................ 5817720-66 .......................................... 5817730 ................................................ 5917735 ................................................ 59

1900019800 ................................................ 6019810 ................................................ 6019820 ................................................ 60

2100021500 ................................................ 7421500-6.............................................. 7421500-AE .......................................... 7521500-AER ........................................ 7521500-16 .......................................... 7621500-19 .......................................... 7621500-IRMA ...................................... 7721500-IRMA-6 .................................. 77

2200022010 ................................................ 7822080 ................................................ 7822100 ................................................ 7922200 ................................................ 7922500 ................................................ 79

2300023500 ................................................ 8023500-6.............................................. 8023500-18 .......................................... 8123500-AE .......................................... 8123500-IRMA ...................................... 8223500-IRMA-6 .................................. 8223510 ................................................ 8323710 ................................................ 8323730 ................................................ 8423740 ................................................ 84

2400024020 ................................................ 8524030 ................................................ 8524040 ................................................ 8624050 ................................................ 8624060 ................................................ 8724200 ................................................ 8724500 ................................................ 8824500-45 .......................................... 8824500-90 .......................................... 8824700 ................................................ 8924700-45 .......................................... 8924720 ................................................ 9024720-45 .......................................... 9024900 ................................................ 91

2500025000 ................................................ 9125010 ................................................ 9225500 ................................................ 9225520 ................................................ 9325540 ................................................ 93

2600026200 ................................................ 9426440 ................................................ 9426450 ................................................ 9526700 ................................................ 95

2800028600 .......................................... 70, 9628600-AE .......................................... 96

2900029000 ................................................ 9729112 ................................................ 97

3000030000 .............................................. 11730000-A .......................................... 12030000-A-SS-T .................................. 15130000-C .......................................... 12030000-D .......................................... 12030000-E............................................ 12030000-E1 ........................................ 12130000-E2 ........................................ 12130000-P .......................................... 12130000-PD ........................................ 11730000-PVC ...................................... 269

30000-R .......................................... 12130000-S............................................ 12230000-S-SS-T .................................. 15130000-TSO ...................................... 11830002-ST.......................................... 11830002-ST-A ...................................... 12230500 .............................................. 11930500-A .......................................... 12230802-4CP ...................................... 12330900-9AD ...................................... 123

3100031000 .............................................. 123

3200032100 .............................................. 12432100-39 ........................................ 12432100-81 ........................................ 12532100-AE ........................................ 12532100-AE-81.................................... 12532100-AE-LC1-88 ............................ 12632100-AE-TG .................................. 12632100-TG ........................................ 12632100-SS-AE.................................... 15232100-SS-AE-81 .............................. 15232150 .............................................. 12732160 .............................................. 12732200 .............................................. 12832200-81 ........................................ 12832200-AE ........................................ 12932200-AE-81.................................... 12932200-AE-SD .................................. 13032200-SD ........................................ 13032200-SS.......................................... 15332300 .............................................. 13132300-81 ........................................ 13132330 .............................................. 13232330-SD ........................................ 132

3400034710 .............................................. 13334720 .............................................. 13334920 .............................................. 134

3500035100 .............................................. 13435100-PVC ...................................... 27135130 .............................................. 13535130-14-1 ...................................... 13535170 .............................................. 136

3700037800 .............................................. 13637800-PVC ...................................... 27137810 .............................................. 13737820 .............................................. 13737830 .............................................. 13837840 .............................................. 13837900 .............................................. 13937960 .............................................. 139

TOC Index Intro.qxd 3/28/08 1:26 PM Page 4

NUMERICAL INDEXNUMERICAL INDEX

5

SERIES NO. PAGE SERIES NO. PAGE SERIES NO. PAGE SERIES NO. PAGE

3800038040 .............................................. 14038250A ............................................ 14038420 .............................................. 14138420-IGS........................................ 14138620-40 ........................................ 14238640 .............................................. 14238820 .............................................. 14338830 .............................................. 14338850 .............................................. 14438930 .............................................. 144

3900039240 .............................................. 14539600 .............................................. 14539720 .............................................. 14639960 .............................................. 146

4000040300 .............................................. 15440320 .............................................. 15440340 .............................................. 15540460 .............................................. 15540520 .............................................. 15640580 .............................................. 156

4900049300 .............................................. 16249300-LF.......................................... 16249300-LF-NB.................................... 16349300-NB ........................................ 16349320A ............................................ 16449320A-LF ...................................... 16449320A-LF-NB ................................ 16549320A-NB...................................... 16549320-PVC ...................................... 27249340A ............................................ 16649340A-LF ...................................... 16649340A-LF-NB ................................ 16749340A-NB...................................... 16749360A ............................................ 16849360A-LF ...................................... 16849360A-LF-NB ................................ 16949360A-NB...................................... 16949400 .............................................. 17049400-LF.......................................... 17049400-LF-NB.................................... 17149400-NB ........................................ 17149420 .............................................. 17249420-LF.......................................... 17249420-LF-NB.................................... 17349420-NB ........................................ 17349500 .............................................. 17449500-LF.......................................... 17449500-LF-NB.................................... 17549500-NB ........................................ 17549520A ............................................ 17649520A-LF ...................................... 17649520A-LF-NB ................................ 17749520A-NB...................................... 17749580A ............................................ 178

49580A-LF ...................................... 17849580A-LF-NB ................................ 17949580A-NB ...................................... 17949700 .............................................. 18049700-LF.......................................... 18049700-LF-NB.................................... 18149700-NB ........................................ 18149720 .............................................. 18249720-LF.......................................... 18249720-LF-NB.................................... 18349720-NB ........................................ 18349850 .............................................. 18449870A ............................................ 184

5500055000 ...................................... 185, 18855000-1 .......................................... 18855000-5 .......................................... 18955000-1-SD .................................... 18955000-1-SQ...................................... 19055000-1-12 ...................................... 19055000-1-13 ...................................... 191

5600056670 .............................................. 19156670-SS.......................................... 157

5700057008-Z-CI ...................................... 19257008-Z-1 ........................................ 19257008-Z-1-SD .................................. 19257008-Z-1-SQ .................................. 19357008-Z-1-12 .................................. 19357008-Z-LT ...................................... 193

5800058360 .............................................. 19458360-PVC ...................................... 27258460A ............................................ 19458460A-AE ...................................... 19558540 .............................................. 19558580 .............................................. 19658580-1 .......................................... 19658580-1-SD...................................... 19758580-1-SQ...................................... 19758600 .............................................. 19858610 .............................................. 19858620 .............................................. 19958630 .............................................. 19958640 .............................................. 20058650 .............................................. 20058680 .............................................. 20158600-CO ........................................ 20158600-COT ...................................... 20258600-PLG ...................................... 20158610-CO ........................................ 20258610-COT ...................................... 20258630-CO ........................................ 20258630-COT ...................................... 20358640-CO ........................................ 20358640-COT ...................................... 203

58900 .............................................. 20458910 .............................................. 204

60000CEGOLD-2000.................................. 220EGOLD-1000.................................... 220GI 2000A.......................................... 21960100H ............................................ 21160100H-ET ...................................... 21260100H-EXT .................................... 21260100H-GRD.................................... 21160100H-RT ...................................... 21360100-SA ........................................ 21460100-SA-ET.................................... 21560100-SA-RT.................................... 21560115A ............................................ 21660117A ............................................ 21660115-SA ..........................................21660210A ............................................ 21760210A-SAP .................................... 21760210A-EXT .................................... 21860210A-ISI ...................................... 21860300A ............................................ 21960500-EST........................................ 22660500B ............................................ 22560500B-EXT .................................... 22560610-EST........................................ 22860610A ............................................ 22760610A-EXT .................................... 22760810 .............................................. 22961000 .............................................. 23061030 .............................................. 23061040A ............................................ 23161070 .............................................. 23161080 .............................................. 23261800 .............................................. 232

6700067100A ............................................ 23567360 .............................................. 23567360-DH ........................................ 23667400 .............................................. 23667500 .............................................. 23767600 .............................................. 23767650 .............................................. 23867720 .............................................. 23867800 .............................................. 239

7100071000 .............................................. 24571020 .............................................. 24571050 .............................................. 24671070 .............................................. 24671400 .............................................. 24771450 .............................................. 24771600 .............................................. 24871650 .............................................. 248

7500075000 .............................................. 25175000-S............................................ 251

7600076000 .............................................. 25476010 .............................................. 25576300 .............................................. 25576400 .............................................. 25576500 .............................................. 25676600 .............................................. 25676700 .............................................. 25676800 .............................................. 256

8500085220 .............................................. 25885800 .............................................. 25885810 .............................................. 25985903-Z............................................ 259

8800088100 .............................................. 26088210 .............................................. 26088250 .............................................. 26188300 .............................................. 26188400 .............................................. 26288450 .............................................. 26288550 .............................................. 26388560 .............................................. 26388600 .............................................. 26488900 .............................................. 26488910 .............................................. 26588950 .............................................. 26588970 .............................................. 266

STRAINERSA .............................................. 110, 2706AD .................................................. 1106AF .................................................. 1105C .................................................... 111D ...................................................... 111E ...................................................... 111E1 .................................................... 1127E2 .................................................. 1127E3 .................................................. 1126F .................................................... 113F4 & F6 ............................................ 113F8 & F9 ............................................ 113G ...................................................... 114H ...................................................... 114M...................................................... 114P ...................................................... 115R ...................................................... 115S .............................................. 115, 270T ...................................................... 1162W.................................................... 116WF6A .............................................. 116WF6S................................................ 116

TOC Index Intro.qxd 3/28/08 1:26 PM Page 5

ALPHABETICAL INDEXALPHABETICAL INDEX

6

DESCRIPTION PAGE DESCRIPTION PAGE DESCRIPTION PAGE DESCRIPTION PAGE

AAbbreviations . . . . . . . . . . . . . . . . . . 7ABSORBOTRON® Arresters . . . . . . . 251

Fixture-Unit Ratings . . . . . . . . . 249Installation Diagrams . . . . . . . . 250

Access CoversFloor. . . . . . . . . . . . . . . . . . 198-203Parking Lot. . . . . . . . . . . . . 201-203Wall . . . . . . . . . . . . . . . . . . 198-203

Acid-Resisting Drains . . . . . . . 162-184 . . . . . . . . . . . . . . . . . . . 151-157

Acid-Resisting Floor Sinks . . . 162-184. . . . . . . . . . . . . . . . . . . 154-156

AdaptersHub . . . . . . . . . . . . . . . . . . 263-264No-Hub . . . . . . . . . . . . . . . . . . . 262Spigot . . . . . . . . . . . . . . . . . . . . 262Trap Primer . . . . . . . . . . . . . . . . 261

Adjustable Floor DrainsCast Iron . . . . . . . 120-123, 125-128Stainless Steel . . . . . . 148, 151-152

Adjustable Roof Drains. . . . . . . . 72-73. . . . . . . . . . . . . . . . . . 75, 81, 96

Adjustable Strainers w/BodiesCast Iron . . . . . . . 100-101, 120-123Stainless Steel . . . . . . 148, 151-152

Affiliations . . . . . . . . . . . . . . . . . . . . . 2Air Gaps . . . . . . . . . . . . . . . . . 264-265Air Inlets. . . . . . . . . . . . . . . . . 265-266Alignment Tool. . . . . . . . . . . . . . 41, 45

. . . . . . . . . . . . . . . . 48-49, 42-55Area Drains

Cast Iron . . . . . . . . . . . . . . 124-146Stainless Steel . . . . . . 148, 152-153

Arresters, Water Hammer . . . . 249-251

BBackwater Valves

Ball Float . . . . . . . . . . . . . . 234-235Comb. Check & Gate . . . . . 235-236Features. . . . . . . . . . . . . . . . . . . 233How to Order . . . . . . . . . . . . . . 234Offset . . . . . . . . . . . . . . . . . 236-237Pit Type . . . . . . . . . . . . . . . . . . . 238Straight-Through Pattern . . 234-236Swing-Check . . . . . . . . . . . 235-239Terminal . . . . . . . . . . . . . . . 238-239

Backwater Valve Drains . . . . . 140, 238Balcony Drains. . . . . . . . . . . . . . . . . 88Basement Drains . . . . . . . . . . . . . . 140Bearing Pan (Drain Receiver) 61, 64-65Blood Drains . . . . . . . . . . . . . . . . . 127Boiler Room Drain . . . . . . . . . 138-140Butt Weld Outlet . . . . . . . . . . . . . . 150

CCan Wash Drain

Acid-Resisting . . . . . . . . . . . . . . 184Cast Iron . . . . . . . . . . . . . . . . . . 145

Carriers, ClosetAdapter Types . . . . . . . . . . . . 12, 23Adjustable Commercial . . . . . . . . 38Adjustable Close . . . . . . . . . . 32-36Adjustable Horizontal . . . . . . 24-25Adjustable On-Stack . . . . . . . 26-31Adjustable, Vertical . . . . . . . . 26-31Detention Type . . . . . . . . 13, 18, 37Features . . . . . . . . . . . . . . . . . 14-16Floor-Mounted Back Outlet . . . . . 20How to Order . . . . . . . . . . . . . . . . 9Hub & Spigot . . . . 25, 27, 29, 31-33Institutional . . . . . . . . . . . . . . 18, 37Installation Diagrams . . . 10,18,19,22Nipple Selection . . . . . . . . . . . . . 18No-Hub . . . . . . . . . . . . . . 24, 26, 28

. . . . . . . . . . . . . . . . . . 30, 34-37

Options Illustrated . . . . . . . . . 17-20Wheelchair . . . . . . . . . . . . . . . 21-22Carrier Selection . . . . . . . . . . . 9, 21Wide Chase . . . . . . . . . . . . . . 16-17

Carriers, CoolerDrinking Fountain . . . . . . . . . 53, 55How to Order . . . . . . . . . . . . . . . 39

Carriers, LavatoryAlignment Tool . . . . . . . . . . 41, 459Corner Type . . . . . . . . . . . . . . . . . 53Features . . . . . . . . . . . . . . . . . 42-43Floor-Mount

Concealed Arms . . . . . . . . . . . 46Exposed Arms . . . . . . . . . . 48-49

Hanger Plate . . . . . . . . . . . . . 52-54How to Order . . . . . . . . . . . . . . . 39Options Illustrated. . . . . . . . . . . . 44Wall-Mount

Concealed Arms. . . . . . . . . 46-48Exposed Arms . . . . . . . . . . 50-51Hanger Plate . . . . . . . . . . . . . . 56

Carriers, SinkAlignment Tool . . . . . . . . . . . . . . 45Floor-Mount

Exposed Arms . . . . . . . . . . 49, 58w/Hanger Plate . . . . . . . . . . . . 58Hanger Plate w/Adapter . . . . . 59Hanger Plate w/Fitting . . . . . . 59

How to Order . . . . . . . . . . . . . . . 39Options Illustrated. . . . . . . . . . . . 44

Carriers, UrinalAlignment Tool . . . . . . . . . . . . . . 45Floor-Mount Hanger Plate. . . 52, 55How to Order . . . . . . . . . . . . . . . 39Wall-Mount Hanger Plate . . . 56-57

Cast Stainless Steel . . . . 151-153, 157 Chemical Resistance Chart . . . . . . 149Cleanouts

Ferrules . . . . . . . . . . . . . . . . . . . 204How to Order . . . . . . . . . . . . . . 186Plugs . . . . . . . . . . . . . . . . . . . . . 195Stainless Steel . . . . . . . . . . . . . . 157Trap Drains w/Cleanouts . . . . . . 119

. . . . . . . . . . . . . . . . . . . 140-142Cleanout Access Covers

Floor. . . . . . . . . . . . . . 196-197, 201Floor w/Cleanout. . . . . . . . . . . . 202Wall . . . . . . . . . . . . . . . . . . 198-200Wall w/Cleanout . . . . . . . . 201-203

Cleanouts, AdjustableFinished Areas . . . . . . . . . . 188-201PVC . . . . . . . . . . . . . . . . . . . . . . 272Special-Duty . . . . . . . 189, 192, 197Unfinished Areas . . . . 188-189, 192

. . . . . . . . . . . 194, 196-197, 201Closet Fittings . . . (See Closet Carriers)Composition Deck Drains . . . . . 80, 82

85-87Connectors

Hub . . . . . . . . . . . . . . . . . . 262-265Gasket, JIFFEE-JOINT. . . . . . . . . . 60No-Hub Spigot. . . . . . . . . . . . . . 262Spigot . . . . . . . . . . . . . . . . . . . . 262

DDeck Clamps . . . . . . . . . . . . . . . 61, 65Deck Drains

Composition Roof . . . . . . . . . 85-87Promenade . . . . . . . . . . . . . . . . . 80-84P Traps, Cast Iron . . . . . . . . . . . . . . 260Deep Seal Trap Drains . . . . . . . . . . 260Dental Sink Interceptors . . . . . 230-231Distribution Unit . . . . . . . . . . . . . . 261Drains

Acid-Resisting . . . 151-156, 162-184Adjustable w/Strainers . . . . . . . . . .

Cast Iron . . . . . . . . . . . . 120-122

Adjustable, FloorCast Iron . . . . . . . . . . . . 120-123. . . . . . . . . . . . . 125-126129-130Stainless Steel . . . . 148, 151-152

Adjustable, Roof . . . . . . . 75, 81, 96Area w/Backwater Valve . . . . . . 140Balcony . . . . . . . . . . . . . . . . . . . . 88Basement . . . . . . . . . . . . . . . . . 140Blood. . . . . . . . . . . . . . . . . . . . . 127Boiler Room . . . . . . . . . . . . 138-140Combination/Cleanouts . . . . 119, 122

. . . . . . . . . . . . . . . . . . . . . 140-144Dairy (See Floor Sinks)

Stainless Steel . . . . . . . . 154-156Drip Drains . . . . . . . . . . . . . 112-113Driveway . . . . . . . . . . . . . . 254-255Elevator Pit . . . . . . . . . . . . . . . . 238Equipment Room. . . . . . . . . . . . 135Extended Rim . . . . . . . . . . . 112,121Floor Drain Bodies

Cast Iron . . . . . . . . . . . . 117-119PVC. . . . . . . . . . . . . . . . . . . . 269

Floor SinksAcid-Resisting, CI. . . . . . 162-184Stainless Steel . . . . . . . . 154-156

Flushing RimCast Iron . . . . . . . . . . . . . . . . 184

Food Processing AreaCast Iron . . . . . . . . . . . . 162-184Stainless Steel . . . . . . . . 154-156

Funnel . . . . . . . . . . . . . . . . 112-113Garage . . . . . . . . . . . . . . . 127, 130

. . . . . . . . . . . . 132-133, 142-143Garbage Can Wash

Cast Iron . . . . . . . . . . . . . . . . 145Gasoline . . . . . . . . . . . . . . . . . . 141Gutter, Roof. . . . . . . . . . . . . . . . . 88Hospital . . . . . . . 162-184, 151-156How to Order

Floor . . . . . . . . . . . . . . . . . . . . 99Roof . . . . . . . . . . . . . . . . . . . . 64Stainless Steel. . . . . . . . . . . . 150Trench . . . . . . . . . . . . . . . . . . 253

IndustrialCast Iron . . . . . . . . . . . . 124-146Stainless Steel . . . . . . . . 152-156

Isolation Deck, Roof . . . . . . . . . . 97IRMA, Roof . . . . . . . . . . . . . . 77, 82Key Lock, Floor . . . . . . . . . . . . . 126LEVELEZE® Drains

Floor . . . . 125-126, 129-130, 139Roof . . . . . . . . . . . . . . 75, 81, 96

Loading Dock . . . . . . . . . . . . . . 133NON-CLOG . . . . . . . . . . . . 111, 120Overflow

Fountain . . . . . . . . . . . . . . . . 114Roof . . . . . . . . . . . . . . . . . 76, 79Scupper . . . . . . . . . . . . . . . 89-91

Packing HouseAcid-Resisting . . . . . . . . 182-184Cast-Iron . . . . . . . . 127, 139,144Stainless Steel . . . . 148, 154-156

Parking DeckFloor . . . . . . . 127, 130, 132-133Roof. . . . . . . . . . . . . . . . . . 83-84

Parapet. . . . . . . . . . . . . . . . . . 89-90Pit

Cast Iron . . . . . . . . . . . . . . . . 238Planting Area. . . . . . . . . . . . . . . 145Plaza . . . . . . . . . . . . . . . . . . . . . . 87Promenade. . . . . . . . . . . . 80-84, 87PVC . . . . . . . . . . . . . . . . . . 269, 271Ramp . . . . . . . . . . . . . 144, 254-255Refrigerator (See Floor Sinks)Roof (See Roof Drains)Sill Drain . . . . . . . . . . . . . . . . . . . 88Slaughter House

Acid-Resisting . . . . . . . . 162-184Cast Iron . . . . . . . . 127, 139, 144Stainless Steel . . . . 148, 154-156

Stainless SteelArea. . . . . . . . . . . . 148, 152-156Floor . . . . . . . . . . . 148, 151-156

Toilet Rooms . . . . 110-111, 114-122Trench (See Trench Drains)Volatile Liquid . . . . . . . . . . . . . . 141

Drain Receivers (Sump Receivers) . . . . . . . 61, 64-65

Drain Tile Connectors . . . . . . . 262-264

EElectronic

Grease Interceptors . . 208, 211, 219Grease/Oil Level Detectors . . . . 208

. . . . . . . . . . . . . . . . . . . 211, 220Sensing and Alarm Probe . . . . . 217

Elevator Pit Drains . . . . . . . . . . . . . 238Enclosed Grease Interceptor . . 212, 215Equipment Room Drains . . . . . . . . 135Expansion Joints, Roof . . . . . . . . . . . 94Extension Collars

Fixed, Floor . . . . . . . . . . . . . . . . 109Fixed, Roof . . . . . . . . . . . . . . 61, 65LEVELEZE® Floor. . . . . . . . . 125-126

129-130, 139LEVELEZE® Roof . . . . . 75-76, 81, 96

FFabricated Stainless Steel . . . . 154-156Finishes & Materials . . . . . . . . . . . . . 8Fittings (See Carriers)

Institutional . . . . . . . . . . . 13, 18, 37Prison . . . . . . . . . . . . . . . 13, 18, 37

Fixed Air Gaps . . . . . . . . . . . . 264-265Fixed Supports (See Carriers)Fixture Carriers

Alignment Tool . . . . . . . . . . . 41, 45How to Order . . . . . . . . . . . . . . . 39Lavatory . . . . . . . . . . . . . . 46-54, 56Sink . . . . . . . . . . . . . . . . . . . . 58-59Urinal . . . . . . . . . . . . . . . 52, 55, 57Water Cooler . . . . . . . . . . . . . 53-55

Flashing Sleeves . . . . . . . . . . . . . 94-95FLO-SEPTOR® Drains. . . . . . . . . . 92-93Flooding Water Drains. . . 75-76, 92-93Floor Access Covers (See Cleanouts)Floor Cleanouts (See Cleanouts)

Drains (See Drains)Floor Sinks

How to Order . . . . . . . . . . . . . . 161Acid-Resisting . . . . . . . . . . 162-184Stainless Steel . . . . . . . . . . 154-156PVC . . . . . . . . . . . . . . . . . . . . . . 272

FLO-SET® Roof Drains . . . . . . . . . . . 96Flow Control Roof Drains . . . . . . . . 96Flow Control Fittings . . . . . . . . . . . 221Frames & Grates (Trench) . . . . 255-256Fresh Air Inlets . . . . . . . . . . . . 265-266Funnels . . . . . . . . . . . . . . . . . . . . . 113Funnel Drains

(See Series Floor Drain w/Funnel)

GGarbage Can Wash Drains

Acid-Resisting . . . . . . . . . . . . . . 184Cast Iron . . . . . . . . . . . . . . . . . . 145

Gasket, JIFFEE-JOINT . . . . . . . . . . . . 60Gasoline Drains . . . . . . . . . . . . . . . 141Grates, Trench. . . . . . . . . . . . . 255-256Grates & Frames, Trench . . . . . 255-256Grease Interceptors

Electronic. . . . . . . . . . 208, 211, 219Enclosed . . . . . . . . . . . . . . 212, 215High Volume. . . . . . . . . . . . 217-218How to Order . . . . . . . . . . . . . . 206

TOC Index Intro.qxd 3/28/08 1:26 PM Page 6

ALPHABETICAL INDEXALPHABETICAL INDEX

7

DESCRIPTION PAGE DESCRIPTION PAGE DESCRIPTION PAGE DESCRIPTION PAGE

Low Boy . . . . . . . . . . . . . . . . . . 216Manual Clean . . . 211-212, 217-218Recessed . . . . . . . . . . . . . . 213, 215Semi-Automatic Draw-Off . . 214-215

Grease Recovery Device. . . 205, 211, 219

HHair Interceptors. . . . . . . . . . . 230-232Hospital Interceptors . . . . . . . 230-232Hub Connectors . . . . . . . . . . . 262-265Hydrants

Features. . . . . . . . . . . . . . . . . . . 240How to Order . . . . . . . . . . . . . . 241Installations. . . . . . . . . . . . . . . . 244Integral Vacuum Breaker . . 245-246Mild Climate . . . . . . . . . . . 245-246Non-Freeze. . . . . . . . . . . . . 245-248Parts List . . . . . . . . . . . . . . . . . . 243Repair Kits. . . . . . . . . . . . . . . . . 242Wall . . . . . . . . . . . . . . 245-246, 248Yard . . . . . . . . . . . . . . . . . . 247-248

HYDRASAN® I, Anti-Siphon. . . 245-246

IInlets, Fresh Air . . . . . . . . . . . . 265-266Interceptors

Checklist . . . . . . . . . . . . . . . . . . 206Dental Labs . . . . . . . . . . . . 230-232External Storage Tanks . . . 226, 228Flow Control Fittings . . . . . . . . . 221Grease . . . . . . . . . . . . . . . . 200-219Grease Recovery Device . . . . . . 205

. . . . . . . . . . . . . . . . . . . 211, 219Hair . . . . . . . . . . . . . . . . . . 230-232Industrial. . . . . . . 217-218, 227-228Installations. . . . . . . . . . . . 210, 224Lint. . . . . . . . . . . . . . . . . . . 230-232Oil . . . . . . . . . . . . . . . . . . . 222-229Oil Sludge . . . . . . . . . . . . . . . . . 229Plaster . . . . . . . . . . . . . . . . 230-231Sediment . . . . . . . . . . . . . . 230-232Sensing and Alarm Probe . . . . . 217Sizing

Grease . . . . . . . . . . . . . . . . . 207Oil . . . . . . . . . . . . . . . . . . . . . 223

SolidsDental Labs . . . . . . . . . . 230-232Hair . . . . . . . . . . . . . . . . 230-232Jewelry . . . . . . . . . . . . . . . . . 230Lint . . . . . . . . . . . . . . . . 230-232Plaster . . . . . . . . . . . . . . 230-231

Isolation Deck Drain . . . . . . . . . . . . 97

JJoints, Roof Drain Expansion . . . . . . 94JIFFEE-JOINT Gasket . . . . . . . . . . . . 60JIFFEE-SET Gasket . . . . . . . 61, 98, 107

KKey Lock Drain. . . . . . . . . . . . . . . . 126

LLavatory Fixture Supports

(See Fixture Carriers)

LEVELEZE®

Cleanouts . . . . . . 185, 188-193, 195Floor Drains . . 125-126, 129-130, 139Roof Drains . . . . . . . . 75-76, 81, 96

Loading Dock Drain . . . . . . . . . . . . 133Low Boy Grease Interceptor . . . . . 216

MMaterials & Finishes . . . . . . . . . . . . . 8Mop Sink (See Floor Sinks)

NNipples, Closet Carriers . . . . . . . . . . 18

Nozzle, Downspout . . . . . . . . . . . . . 92NON-CLOG Drains . . . . . . . . . 111, 120

OOil Separators

Extended Top. . . . . . . . . . . 225, 227External Storage Tanks . . . 226, 228Gravity Draw-Off . . . . . . . . 224-227High-Volume . . . . . . . . . . . 227-228Installations. . . . . . . . . . . . . . . . 224Sizing. . . . . . . . . . . . . . . . . . . . . 223

Options, IllustratedCarriers

Closet . . . . . . . . . . . . . . . . . . . 20Fixture. . . . . . . . . . . . . . . . . . . 44

Floor Drains. . . . . . . . . . . . . . . . 108Floor Sinks. . . . . . . . . . . . . . . . . 161Roof Drains . . . . . . . . . . . . . . . . . 65

Ordering InformationBackwater Valves . . . . . . . . . . . 234Carriers

Closet . . . . . . . . . . . . . . . . . . . . 9Fixture. . . . . . . . . . . . . . . . . . . 39

Cleanouts . . . . . . . . . . . . . . . . . 186Floor Drains. . . . . . . . . . . . . . . . . 99Floor Sinks. . . . . . . . . . . . . . . . . 161Hydrants . . . . . . . . . . . . . . . . . . 241Interceptors . . . . . . . . . . . . . . . . 206Roof Drains . . . . . . . . . . . . . . . . . 64Stainless Steel . . . . . . . . . . . . . . 150Trench Drains . . . . . . . . . . . . . . 253

P“P” Traps

Cast Iron . . . . . . . . . . . . . . . . . . 260Packing House Drains

Acid-Resisting . . . . . . . . . . 182-184Cast Iron . . . . . . . . . . 127, 139, 144Stainless Steel . . . . . . 148, 154-156

Parapet Drains . . . . . . . . . . . . . . 89-90Parking Deck Drains

Floor. . . . . . . . . . 127, 130, 132-133Roof . . . . . . . . . . . . . . . . . . . . 83-84

Parking Lot Access Cover . . . . 201-203Planting Area Drains . . . . . . . . . . . 145Plaster Interceptor . . . . . . . . . 230-231Plaza Drains. . . . . . . . . . . . . . . . . . . 87Plugs, Cleanout . . . . . . . . . . . . . . . 195Promenade Roof Drains . . . . 80-84, 87PVC Products

Drain Bodies. . . . . . . . . . . . . . . 269Drain Assemblies. . . . . . . . 270-271Floor Sink . . . . . . . . . . . . . . . . . 272Cleanout. . . . . . . . . . . . . . . . . . 272

RReceptor Drains . . . . . . . . . . . . . 92-93Riser Sleeves. . . . . . . . . . . . . . . . 94-95Roof Drains

Adjustable LEVELEZE® . . 75-76, 81, 96Balcony . . . . . . . . . . . . . . . . . . . . 88Composition Deck . . . 80, 82, 85-87Controlled Flow (FLO-SET®). . . . . 96Drain Receiver . . . . . . . . . 61, 64-65Extensions

Fixed . . . . . . . . . . . . . . . . . 61, 65LEVELEZE®. . . . . . . . . . 61, 75, 96

Flashing Sleeves. . . . . . . . . . . 94-95FLO-SET® . . . . . . . . . . . . . . . . . . . 96Flooding Water Dam . . 75-76, 92-93How to Order . . . . . . . . . . . . . . . 64IRMA . . . . . . . . . . . . . . . . . . . 77, 82Indirect Waste . . . . . . . . . . . . 92-93Isolation Deck . . . . . . . . . . . . . . . 97Options, Illustrated . . . . . . . . . . . 65Overflow . . . . . . . . . . . 75-76, 92-93Parapet. . . . . . . . . . . . . . . . . . 89-90

Parking Deck . . . . . . . . . . . . . 83-84Plaza . . . . . . . . . . . . . . . . . . . . . . 87 Promenade Deck . . . . . . . 80-84, 87Sill . . . . . . . . . . . . . . . . . . . . . . . . 88Sizing . . . . . . . . . . . . . . . . . . . 66-69

SSanitary Floor Drains (Floor Sinks)

Cast Iron . . . . . . . 162-184, 151-157Stainless Steel . . . . . . 148, 154-156

Sediment Interceptors . . . . . . 230-232Sensing and Alarm Probe . . . . . . . 217Separators, Oil . . . . . . . . . . . . 222-229Sewer Valves (See Backwater Valves)Shock Absorbers, Arresters. . . . . . . 251Shower Room Drains . . . . . . . 110-111

. . . . . . . . . . . . . . . . . . . 114-122Sill Drains. . . . . . . . . . . . . . . . . . . . . 88Sinks, Floor

(SUPER-FLO-SEPTORS®) . . . 162-184Sink Fixture Supports (See Carriers)Sleeves, Stack . . . . . . . . . . . . . . . 94-95Solids Interceptors . . . . . . . . . 230-232Spigot Adapters . . . . . . . . . . . . . . . 262Stack Sleeves . . . . . . . . . . . . . . . 94-95Stainless Steel Products

Cast Stainless Cleanouts . . . . . . . . . . . . . . . 157Floor Drains . . . . . . . . . . 151-153

Fabricated Stainless SteelFloor Drains/Sinks . . . . . 154-156Grease Recovery Device . . . . 219

Standards, ANSI, ASSE, PDI . . . . . . . . 2Standing Water Guard . . . . . . . . 75-76Strainers

Adjustable . . . . . . . . . . . . . 110-116Sediment . . . . . . . . . . . . . . . . . . 111

Sump Receiver (Drain Receiver) . . . . . . . . 61, 64-65

TTraps

Deep Seal . . . . . . . . . . . . . . . . . 260w/Drains . . . 118-119, 122, 140-142w/Funnel . . . . . . . . . . . . . . . . . . 260Grease . . . . . . . . . . . . . . . . 205-219Hair . . . . . . . . . . . . . . . . . . 230-232Lint. . . . . . . . . . . . . . . . . . . 230-232Oil . . . . . . . . . . . . . . . . . . . 222-229Plaster . . . . . . . . . . . . . . . . 230-231Sediment . . . . . . . . . . . . . . 230-232Stainless Steel . . . . . . . . . . . . . . 219

Trap Primers. . . . . . . . . . . . . . . . . . 261w/Distribution Unit . . . . . . . . . . 261

Trench DrainsHow to Order . . . . . . . . . . . . . . 253w/Frames . . . . . . . . . . . . . . 255-256

UUrinal Supports (See Carriers)

VValves (See Backwater Valves)Vent Caps, Vandal-Proof . . . . . . . . . 95Vent Stack Sleeves . . . . . . . . . . . 94-95

WWall Access Covers . . . . . . . . . 198-203Wall Hydrants . . . . . . . . . 245-246, 248Wall-Hung Fixture Supports

(See Carriers)Water Hammer Arresters . . . . . . . . 251

YYard Hydrants . . . . . . . . . . . . . 247-248

Abbreviations Usedin This CatalogAdj. AdjustableANSI American National Standards

InstituteA.R.E. Acid Resisting EnamelASME American Society of

Mechanical EngineersASPE American Society of

Plumbing EngineersASSE American Society of Sanitary

EngineersASTM American Society for Testing

& MaterialsAux. AuxiliaryBr. BranchBrz. BronzeBWV Backwater ValveCap. CapacityC.I. Cast IronCISPI Cast Iron Soil Pipe InstituteCP Chrome PlatedDim. DimensionDWV Drain, Waste, VentExt. ExtensionFtg. FittingGalv. GalvanizedG.P.H. Gallons Per HourG.P.M. Gallons Per MinuteG.R.D. Grease Recovery DeviceH.P.T. Hose Pipe ThreadID Inside DiameterIRMA Insulated Roof Membrane

AssemblyJSP Josam Service ProgramL.H. Left HandNB Nickel BronzeN.P.S.L. National Pipe Straight LocknutN.P.T. National Pipe TaperO.C. On CenterOD Outside DiameterPDI Plumbing and Drainage

InstitutePOA Price on ApplicationR.H. Right HandS.F. Satin FinishSS Stainless SteelSV Service WeightSW Service WeightXH Extra Heavy

TOC Index Intro.qxd 3/28/08 1:26 PM Page 7

8

MATERIALS & FINISHESMATERIALS & FINISHESMaterialsBRONZE:JOSAM bronze is a semi-red brass, generally used with a satin finish and is also an excellent base for chromium plating. All JOSAMchromium plated bronze is cast with this alloy and results in a lasting bright appearance which is stain resistant and maintenance free.Use of bronze instead of cast iron may reduce load classification.

CAST IRON:JOSAM gray iron is produced to ASTM Standards and has a 25,000 p.s.i. minimum tensile strength. The use of quality materials and themost modern production methods results in sound, dependable metal with good corrosion resistance.

DUCTILE IRON:A nodular graphite iron with the strength of steel is supplied for gratings, which must carry the heaviest loads.

NIKALOY:This nickel bronze alloy is used when a high strength harder bronze material is needed for chemical resistance and a long-lasting, easily-maintained bright finish. Use of Nikaloy instead of cast iron may reduce load classification.

ACID-RESISTING COATINGS:Floor Sinks are provided with an acid-resisting porcelain enameled or high-gloss baked epoxy sanitary acid-resisting white coating thathas an excellent appearance and is easy to clean. The acid-resisting coating provided on other cast iron and steel products is a two-part epoxy coating.

STAINLESS STEEL:Stainless steel is commonly used in the dairy, food processing, chemical, pharmaceutical and institutional industries. Available in type304 and 316L stainless steel.

PLATING AND SPECIAL COATINGS:JOSAM bronze is often chromium plated for ease of maintenance and resistance to chlorine. All JOSAM cast iron is dip coated with aquality paint and, when required, special chemical-resistant coatings are furnished for harsh environments. Galvanized coatings aresupplied by a new zinc-rich polymeric coating. This finish conforms to Mil. Spec. MIL-P21035 and is preferred to hot dipped coatings.

FinishesROUGH:This designation applies to Nikaloy and bronze items, which are supplied in an "as cast" condition. All of the features of Nikaloy andbronze are present.

PAINTED:JOSAM’s protective coating is an acrylic latex water-reducible air-dry paint.

SATIN:Low luster finish applied to Nikaloy and bronze products makes them compatible with the present architectural trends calling forexposed hardware to be inconspicuous in appearance. This satin finish has been selected by JOSAM to be standard on all Nikaloy andbronze finished parts.

TOC Index Intro.qxd 3/28/08 1:26 PM Page 8

9

CLOSET CARRIERSCLOSET CARRIERSCA

RRIERS

12704 -LH4 -10

Outlet Size

Option, Left-Hand 4" No-Hub Branch

Option, ABS Extension, through 10-1/2" Wall

How To Order

Types of CarriersThe JOSAM 12000 Series and –32 Wide Chase Closet Carriers for commercial installation suit all makes and types of off-the-floor closet bowls.Simply indicate the information below for the product desired.

CARRIER TYPE APPLICATIONCOMMERCIAL For use with 12000 and –32 Wide Chase Carriers in single,ADJUSTABLE FITTINGS battery or on-stack installation of closet bowls.ON-STACK, HUB & SPIGOT, NO-HUB

COMMERCIAL FITTINGS For commercial on-stack installation of closet bowls.ON-STACK, HUB & SPIGOT, PLASTIC

CLOSE CARRIERS & FITTINGS For installation in soil stack where pipe space is minimum.HUB & SPIGOT, NO-HUB

EXAMPLE: Series No. 12704

Horizontal Fitting & Carrier SelectionDIAGRAM TO DETERMINE LEFT- OR RIGHT-HAND CLOSET FITTINGS

1. If flow in waste line is from the right of the stack, the closet fitting should be a right-hand fitting.2. If flow in waste line is from the left of the stack, the closet fitting should be a left-hand fitting.

TYPICALINSTALLATION

SHOWN

Closet Carriers_08.qxd 4/10/08 5:45 PM Page 9

10

CLOSET CARRIERSCLOSET CARRIERSCA

RRIE

RS

Advantages of Off-The-Floor Plumbing FixturesWHY OFF-THE-FLOOR PLUMBING FIXTURES?The reasons are many – including aesthetics, installation, cost, maintenance and sanitation. This concept in modern plumbing has been acknowledged for manyyears by leading architects, engineers and mechanical contractors to be far superior in all respects to systems with floor-mounted fixtures. The more significantadvantages of off- versus on-the-floor plumbing fixtures and their required support and drainage systems are presented on these pages for your considerationwhen specifications are written.

AESTHETICSIn keeping with the current trends of architectural design toward smooth, uncluttered lines, off-the-floor plumbing fixtures are the necessary practical complementin toilet and restroom décor. Victorian pedestals and unsightly floor-mounted closets of a bygone year cannot be aesthetically integrated in contemporary designs.

INSTALLATIONMany factors, including cost, material, labor required, space, handling and others must be thoroughly evaluated when planning an installation. With on-the-floorwater closets, slabs must be penetrated and sleeved at each fixture to accommodate waste piping which, in many instances, has to be suspended below the slab.

Such suspended piping requires concealment in multi-story installations, thereby necessitating drop or furred ceilings in the rooms below. The fitting and assemblyof waste piping in such installations, as a rule, must be accomplished on the spot with the aid of scaffolding and extra mechanics, which contributes to high con-struction costs and affects not only the mechanical contractor but the structural, floor, wall and ceiling mechanics as well.

Conversely, with off-the-floor fixtures, there is no slab penetration in toilet room areas. The support and piping systems are concealed behind the walls. Such sys-tems are ideally suited to the modern modular plumbing concept as they are readily fabricated either on site or in the contractor’s shop at significant savings overconventional piece-by-piece assembly. A well planned and executed off-the-floor fixture installation today will provide lasting benefits appreciated by future build-ing occupants and owners.

MAINTENANCE AND SANITATIONThe benefits of off-the-floor plumbing will immediately become evident to those involved in maintenance. Mechanically, off- and on-the-floor plumbing installa-tions are similar in terms of service required. However, when service is necessary, it is generally agreed that off-the-floor fixtures and attendant systems are moreeasily maintained. With no obstructions, daily floor cleaning is accomplished more effectively in far less time than needed to work around on-the-floor fixtures.

Toilet rooms are the most susceptible of all rooms to unsanitary conditions. Therefore, sanitation should be the foremost consideration in the design of such rooms.On-the-floor fixtures, regardless of their efficiency or manufacture, provide natural harbors at the base for accumulated filth, which is virtually impossible to remove,never allowing total sanitation. The ever-present problem of floor deterioration adjacent to and under on-the-floor fixtures is completely eliminated with off-the-floor installations. Off-the-floor plumbing fixtures eliminate this potential health hazard, and toilet room floors are clear of obstructions which hamper efforts toachieve proper sanitary maintenance. Another advantage of off-the-floor fixtures is that they provide much greater rentable or usable floor space than do on-the-floor fixtures, and that is a factor which should be considered when fixture selection is made. The specification of off-the-floor fixtures will prove to be a wise andpractical decision.

OFF-THE-FLOOR WATER CLOSETON-THE-FLOOR WATER CLOSET

Closet Carriers_08.qxd 3/27/08 8:56 AM Page 10

11

CLOSET CARRIERSCLOSET CARRIERSCA

RRIERS

Advantages of Off-The-Floor Plumbing FixturesSUPPORT & DRAINAGE SYSTEMSWhen JOSAM entered into the manufacturing of off-the-floor plumbing fixture carriers and fittings, extensive research was conducted into the requirements forsupport and discharge of these fixtures. From this research, the design of the JOSAM line of carriers and fittings evolved, including such innovations as invertiblecarriers to mount either siphon jet or blowout water closets, common vents on back-to-back fittings, dual feet on closet carriers to accommodate all fixture roughingheights in any floor construction and many others.

Our innovations have been copied, but not equaled, and they paved the way for universal acceptance of this line of products. In the ensuing years, this productline has been expanded to meet new requirements as they develop in the dynamic construction industry. The result is today’s most comprehensive range of prod-ucts for off-the-floor plumbing fixture support and drainage.

TYPES OF WATER CLOSETSPrior to the introduction of JOSAM universal carriers, it was necessary to specify carriers for each specific type of water closet. Even though JOSAM has taken thistask out of carrier specifications, water closet types should be understood. There are two basic types of water closets, identifiable by their flushing action, that arenormally used in commercial installations requiring carriers. These are siphon jet and blowout action water closets. The siphon jet bowl is attached to the carrierwith four mounting studs arranged in a rectangular pattern whereas the blowout bowl is mounted on three studs arranged in a triangular pattern, point down. Byinverting the carrier body, JOSAM carriers accommodate either type. Both siphon jet and blowout type water closets are also produced in floor-mounted wall-out-let pattern and require special drainage fitting connections.

SIPHON JET BLOWOUT

This type, because of its quiet, efficient, sanitary flushing action, is usuallyspecified in most commercial, institutional and hotel applications. Water isintroduced into the bowl through the rim and up leg of trap through jetsplaced there to fill the trapway thus creating siphonic action to quicklyevacuate the bowl. The large water surface in the bowl insures sanitation.

This type is particularly suited to heavy use applications such as public facili-ties in stadiums and terminals. The flushing action produced by the jet ofwater in the outlet passage is strong for rapid evacuation of the bowl.Fouling problems are minimal. However, because of the powerful flushingaction, this type of closet is noisy to operate.

ONE CARRIER FOR SIPHON JET ORBLOWOUTCHASE-SAVER® is shipped pre-assembled for siphon jet closets andis quickly inverted for use with blowout closets.

SIPHON JET BLOWOUT

Closet Carriers_08.qxd 3/27/08 8:56 AM Page 11

CLOSET CARRIERS • Pictorial GuideCLOSET CARRIERS • Pictorial Guide

12

CARR

IERS

HORIZONTAL ADJUSTABLE FITTINGS VERTICAL ADJ. FITTINGS12674/12684No-Hub, Single,12674, L.H., 12684, R.H

Page 24

12694No-Hub, Back-to-Back

Page 24

12674/12684-HSHub & Spigot, Single, 12674-HS, L.H., 12684-HS, R.H.

Page 25

12694-HSHub & Spigot, Back-to-Back

Page 25

12704No-Hub, Single, L.H. 2” Vent

Page 26

12704-HSHub & Spigot, Single,L.H. 2” Vent

Page 26

CARRIERS 12000 TRIM PACKS11001With 4” Pipe Grip Adapter

Page 23

11007/11008With 3” & 4” Copper FittingAdapters

Page 23

12000

Page 14

12000-OR

Page 15

12000-32

Pages 16

VERTICAL ADJUSTABLE FITTINGS12704-LH4No-Hub, Single, L.H. 4"Branch, L.H. 2" Vent

Page 26

12704-HS-HLH4Hub & Spigot, Single, L.H. 4"Branch, L.H. 2" Vent

Page 27

12704-RH4No-Hub, Single, R.H. 4"Branch, L.H. 2" Vent

Page 27

12704-HS-HRH4Hub & Spigot, Single, R.H.4" Branch, L.H. 2" Vent

Page 27

12704-D4No-Hub, Single, Two 4”Branches, L.H. 2” Vent

Page 27

12704-HS-HD4Hub & Spigot, Single, Two4” Branches, L.H. 2” Vent

Page 27

VERTICAL ADJUSTABLE FITTINGS12714No-Hub, Single, R.H. 2” Vent

Page 28

12714 -HSHub & Spigot, Single, R.H.2” Vent

Page 28

12714-RH4No-Hub, Single, R.H. 4"Branch, R.H. 2" Vent

Page 28

12714-HS-HRH4Hub & Spigot, Single, R.H.4" Branch, R.H. 2" Vent

Page 29

12714-LH4No-Hub, Single, L.H. 4"Branch, R.H. 2" Vent

Page 29

12714-HS-HLH4Hub & Spigot, Single, L.H.4" Branch, R.H. 2" Vent

Page 29

Closet Carriers_08.qxd 3/27/08 8:56 AM Page 12

CLOSET CARRIERS • Pictorial GuideCLOSET CARRIERS • Pictorial Guide

13

CARRIERS

VERTICAL CLOSE FITTINGS14104Single, On-Stack, 2" Vent

Page 33

14404/14424L.H. Offset, L.H. 2" VentR.H. Offset, R.H. 2" Vent

Page 34

14444Back-to-Back, Offset,2" Vent

Page 34

14464Single, On-Stack, 4" Vent

Page 35

14484Back-to-Back, On-Stack,4" Vent

Page 35

14504Single , On-Stack, 2" Vent

Page 36

90° INSTITUTIONAL CARRIERS15964Vertical, 2” Vent, 4” Branches

Page 37

15984Vertical, 2” Vent, 4” Branches

Page 37

FLOOR-MOUNTED16123Single, On-Stack, 3” PVC Fitting Adapter

Page 38

VERTICAL ADJUSTABLE FITTINGS12714-D4No-Hub, Single, Two 4"Branches, R.H. 2" Vent

Page 29

12714-HS-HD4Hub & Spigot, Single, Two4" Branches, R.H. 2" Vent

Page 29

12724No-Hub, Back-to-Back, 2"Vent

Page 30

12724-HSHub & Spigot, Back-to-Back, 2" Vent

Page 31

12724-VS4No-Hub, Back-to-Back, 4”Branch, 2” Vent Same Side

Page 31

12724-OS4No-Hub, Back-to-Back, 4"Branch, 2" Vent Opposite Side

Page 31

VERTICAL ADJUSTABLE FITTINGS VERTICAL CLOSE FITTINGS12724-HS-HVS4Hub & Spigot, Back-to-Back,Single Branch, 2" Vent

Page 31

12724-D4No-Hub, Back-to-Back,Two 4" Branches, 2" Vent

Page 31

12724-HS-HD4Hub & Spigot, Back-to-Back,Two 4" Branches, 2" Vent

Page 31

14004/14024L.H. Offset, L.H. 2” VentR.H. Offset, R.H. 2” Vent

Page 32

14044Back-to-Back, Offset,2” Vent

Page 32

14064Single, On-Stack, 4" Vent

Page 33

Closet Carriers_08.qxd 3/27/08 8:56 AM Page 13

14

CLOSET CARRIERSCLOSET CARRIERSCA

RRIE

RS

SPECIFICATION: JOSAM 12000-PF Series coated cast iron CHASE-SAVER® II ClosetCarrier with adjustable connection,adjustable pylon feet, ABS extension withintegral test cap, chrome plated trim, coatedaccessories and JIFFEE-SEAL Neoprene fixture gasket, for use with blowout or siphonjet water closets.

JOSAM 12000-PF Series CHASE-SAVER® II Closet Carrier meets the most rigid requirements for securing and supporting water closets. Some of themany specification and installation features are shown below. CHASE-SAVER® II can be used to mount either siphon jet or blow-out closets byinverting the carrier body. This carrier was specifically designed for pre-fabricated plumbing systems and exceeds the requirements of AmericanNational Standard ANSI A112.6.1M-1997. Pre-assembled carrier and pylon feet are packed with all the hardware. The extension and fitting areshipped separately for convenient handling at the fabrication or job site.

12000-PF Series CHASE-SAVER® II Features

BOWL STABILIZER BACK UP WASHERS

Provide gripping power necessary to prevent

water closet from settling out of installed

location over a long period of time.

HARDWARE

Zincbrite plating protects all hardware and cap

nuts are finished in chrome.

ADJUSTABLE EXTENSION

High strength ABS plastic with built-in test cap,

assembled to carrier body with positive taper

threads, easily cut to desired length. Furnished

7" long standard for 1" minimum to 5-1/2"

maximum dimension, and 12" long (specify -10

Option) for 10-1/2" maximum dimension.

CARRIER BODY

Heavy-duty cast iron, compact, invertible for positive support of siphon jet or

blow-out closets, with break-off tabs for rough-in less than standard 5-1/2",

at the base (in siphon jet position), accommodates complete range of rough-

in heights in two models, one (standard) for 4-1/2" through 6" and the other

for higher rough, bolts directly to fitting. Bolt securing standard, stud

securing is optional.

FITTING GASKET

Neoprene gasket with raised "O" ring beads on

both sides provides a positive watertight seal

between fitting and carrier.

PYLON FEET

Heavy-duty cast iron, compact, invertible (same

foot both sides – no rights and lefts) outboard

side mount for easy access to all assembly

hardware, with "Wrap around" carrier retaining

channel (1) which "locks" foot to carrier with

only one bolt (2). Each foot requires only one

floor anchor bolt and has additional

"convenience" slots (3) for securing pre-fab

transport frames, and pipe supports, incorporates

handy elevation scale (4) divided in 1/2"

increments on front to permit roughing-in at

a glance, extends only 3/4" in front of

carrier with flat vertical face and 13-3/4"

height accommodates either standard or

high rough mounting.

ANCHOR FOOT

Cast iron, rotatable, secured to back of fitting by

means of fully threaded rod for complete

adjustment, provides the final link in the 3 point

support system for ultimate stability of the

installation.

FIXTURE GASKET

JIFFEE-SEAL Neoprene Gasket fits all closet

gasket recesses.

1

3

3

42

Closet Carriers_08.qxd 3/27/08 8:56 AM Page 14

15

CLOSET CARRIERSCLOSET CARRIERSCA

RRIERS

JOSAM 12000-OR Series CHASE-SAVER® II Closet Carrier meets the most rigid requirements for securing and supporting water closets. Some of the many specification and installation features are shown below. CHASE-SAVER® II can be used to mount either siphon jet or blow-out closets byinverting the carrier body. This carrier was specifically designed for pre-fabricated plumbing systems and exceeds the requirements of AmericanNational Standard ANSI A112.6.1M-1997. Pre-assembled carrier and pylon feet are packed with all the hardware. The extension and fitting areshipped separately for convenient handling at the fabrication or job site.

12000-OR Series CHASE-SAVER® II Features

BOWL STABILIZER BACK UP WASHERS

Provide gripping power necessary to prevent

water closet from settling out of installed

location over a long period of time.

HARDWARE

Zincbrite plating protects all hardware and cap

nuts are finished in chrome.

ADJUSTABLE EXTENSION

Threaded high strength ABS plastic with built-in

test cap, assembled to carrier body and o-ring

to form a gas and watertight seal. Furnished 6"

long standard, easily cut for 1" minimum to 5-

1/2" maximum dimension. For 12" long exten-

sion (specify -10 Option) for 10-1/2" maximum

dimension.

CARRIER BODY

Heavy-duty cast iron, compact, integral o-ring sealing connection, invertible for

positive support of siphon jet or blow-out closets, with break-off tabs for

rough-in less than standard 5-1/2", at the base (in siphon jet position), accom-

modates complete range of rough-in heights in two models, one (standard) for

4-1/2" through 6" and the other for higher rough, bolts directly to fitting. Bolt

securing standard, stud securing optional.

FITTING GASKET

Neoprene gasket with raised "O" ring beads on

both sides provides a positive watertight seal

between fitting and carrier.

PYLON FEET

Heavy-duty cast iron, compact, invertible (same

foot both sides – no rights and lefts) outboard

side mount for easy access to all assembly hard-

ware, with "Wrap around" carrier retaining

channel (1) which "locks" foot to carrier with

only one bolt (2). Each foot requires only one

floor anchor bolt and has additional "conven-

ience" slots (3) for securing pre-fab transport

frames, and pipe supports, incorporates handy

elevation scale (4) divided in 1/2" increments

on front to permit roughing-in at a glance,

extends only 3/4" in front of carrier with flat

vertical face and 13-3/4" height accommodates

either standard or high rough mounting.

ANCHOR FOOT

Cast iron, rotatable, secured to back of fitting by

means of fully threaded rod for complete adjust-

ment, provides the final link in the 3 point support

system for ultimate stability of the installation.

FIXTURE GASKET

JIFFEE-SEAL Neoprene Gasket fits all closet gas-

ket recesses.

1

3

2

3

4

SPECIFICATION: JOSAM 12000-OR Series coated cast iron CHASE-SAVER® II ClosetCarrier with adjustable connection,adjustable pylon feet, ABS extension withintegral test cap, chrome plated trim, coatedaccessories and JIFFEE-SEAL Neoprene fixturegasket, for use with blowout or siphon jetwater closets.

Closet Carriers_08.qxd 3/27/08 8:56 AM Page 15

16

CLOSET CARRIERSCLOSET CARRIERSCA

RRIE

RS JOSAM -32 Wide Chase Carrier is universal for all applications in any type of construction, providing positive support for either siphon jet orblowout off-the-floor closets whether construction involves monolithic floors, minimum or maximum floor fills and high or low roughing. The carri-er assembly, separate from the fitting and face plate assembly, is ideally suited for installation in wide chases as it can be positioned in or immedi-ately behind the wall where the closet support should be, regardless of stack or drainage line location. The –32 Carrier comes from the factoryshrink wrapped and partially assembled for convenient storage until required for use with any JOSAM adjustable fitting and face plate assembly.

-32 WIDE CHASE CARRIER Features

12000 CARRIER BODY

Compact cast iron heavy-duty construction,

invertible with break-off sections to provide vari-

ous roughing heights to meet all drainage and

pitch requirements for waste line.

COUPLING

Heavy-duty cast iron coupling, threaded to allow

connection between nipple and ABS extension.

12000-32 CARRIER BODY

Compact cast iron heavy-duty construction,

invertible and provides various roughing heights

to meet all drainage and pitch requirements for

waste line.

FIXTURE GASKET

JIFFEE-SEAL Neoprene Gasket fits all closet gas-

ket recesses.

BOWL STABILIZER BACK-UP WASHERS

Provide gripping power necessary to prevent

water closet from settling out of installed loca-

tion over a prolonged period of time.

ANCHOR FOOT

Cast iron, rotatable foot is secured to back of

fitting by means of fully threaded rod for

complete adjustment.

PYLON FEET

Heavy-duty cast iron, compact, invertible (same

foot both sides – no rights and lefts) outboard

side mount for easy access to all assembly hard-

ware. (Same foot as our

standard 12000 Series Carrier.) ADJUSTABLE EXTENSION

High strength ABS plastic with built-in test cap, assembled to body with positive

taper threads, easily cut to desired length. Furnished 7" long standard for 1" mini-

mum to 5-1/2" maximum dimension and 12" long, (specify –10 Option) for 10-1/2"

maximum dimension. Cast iron extensions are available on special order.

SPECIFICATION: JOSAM –32 coated cast iron WideChase Closet Carrier with adjustable closet connection,adjustable pylon feet, ABS extension with integral test cap, chrome plated trim, coated accessories and JIFFEE-SEAL Neoprene fixture gasket, for use withblowout or siphon jet water closets.

NPT NIPPLE

Provided by others.

Closet Carriers_08.qxd 3/27/08 8:56 AM Page 16

17

CLOSET CARRIERSCLOSET CARRIERSCA

RRIERS

12000 Series Minimum Dimensions

-32 Option Minimum Dimensions

Carrier shown in Siphon Jet Position

Carrier shown in Siphon Jet Position

Carrier shown in Blowout Position

Carrier shown in Blowout Position

r FOR DIM. SHORTER THAN 5-1/2" (1" MIN.), CUT EXT.FOR LONGER EXT. (10-1/2" MAX.), SPECIFY -10 OPTION.

* FOR DIM. GREATER THAN 12-1/2", SPECIFY 12000-M1358.

r FOR DIM. LESS THAN 3-3/4” CUT EXT.* MAY VARY 1/4”

ADJUSTABLE EXTENSIONS AVAILABLE FOR –32 OPTION

Wall Length of Length ofThickness Extension Threaded Rod Part No. Description

1" through 5-1/2" 7" 9-1/2" 07095A ABS Extension

5-1/2” through 10-1/2” 12” 14-1/2” 07095E ABS Extension

+_

Closet Carriers_08.qxd 3/27/08 8:56 AM Page 17

18

CLOSET CARRIERSCLOSET CARRIERSCA

RRIE

RS

Nipple SelectionThe key to pipe chase width adaptability of the -32 Wide ChaseCarriers and the component that makes them universal for allinstallation conditions is the 4 inch NPT nipple that connects thecoupling of the carrier assembly to the adjustable fitting faceplate.This nipple is furnished by others, and the recommended length canbe determined by using the chart below.

To provide proper fixture support, the carrier should be set directlybehind or within the wall. To accomplish this in wide pipe chaseswith DWV piping either centered or offset, it is necessary toseparate carrier and drainage fitting as required with nipples thatare longer than 2-7/8."The minimum dimension (A*) wasdetermined using a 2-7/8" length nipple. Nipples ranging in lengthfrom 2-7/8" to 12" in 1 inch increments are identified on this pagefor specification when such construction conditions are encountered.

-32 OPTION RECOMMENDEDLENGTH NIPPLES (BY OTHERS)

A* Length NippleMinimum Chase to Use

9-1/4 2-7/8

10-1/4 4

11-1/4 5

12-1/4 6

13-1/4 7

14-1/4 8

15-1/4 9

16-1/4 10

17-1/4 11

18-1/4 12

Recommended Pipe: 4” Galvanized Steel

Adjustable Carrier Installations

Installation of back-to-back 12000-PF Series Carrier showing min-imum extension.

Installation of 12000-PF Series Carrier in a standard 12"wide pipe chase showing minimum extension.

Installations 90º Double Waste Fitting 15964 &15984 SeriesInstallations of 15964 and 15984 Series double vertical 90º no-hub fittings where a closet and lavatory are installed in each room with one stack serving two rooms.

15964 SERIES SHOWN IN A TYPICAL ROOM BACK DISCHARGE TOILET FACILITY 15984 DOUBLE WASTE VERTICAL FITTING SHOWN INSTALLED IN A TYPICALROOM BOTTOM DISCHARGE TOILET FACILITY LAYOUT

NIPPLE LENGTH DRAWING

CL

Closet Carriers_08.qxd 3/27/08 8:56 AM Page 18

19

CLOSET CARRIERSCLOSET CARRIERSCA

RRIERS

FH Hardware Part #: 565985TMounting Stud and Back-up Nut not included in FH Hardware Kit.

To set bowl using finished hardware group "FH," put ahex nut, back-up washer, and a bowl stabilizer on eachmounting stud.

Adjust with front of back-up nut and washer at finishedwall line.

If the back-up nut and washer are moved to clear irregularities in the finished wall, the extension MUST beadjusted an equal amount.

Place fixture gasket in toilet outlet and hang closet. Assemble fiber washers and JOSAM cap nuts totwo studs on the center line of the closet outlet and oneother stud below and tighten with a wrench.

Assemble fiber washer and JOSAM cap nut to remainingstud, hand tighten and take 1/2 turn with a wrench.

Bowl To Carrier Installation

Extension Length Determination

This is a side view. The enlarged inset shows the depth of the gasket within the groove of the fixture and the extension with properpressure on the gasket.

When the closet is installed on the carrier, the front end of the extension must be located properly in order to compress the gasket enoughso that the gasket's adhesive coated surfaces are in contact with the china and the face of the extension. This will help ensure a tight seal.

For closets which have a groove with a rectangular cross-section, Use this formula: C = A + B - 1/2"

Where: A = Distance from Closet to WallB = Depth of Groove in ClosetC = Distance Extension Extends from Wall

For closets which have a groove with a V-shaped cross-section:Use the above formula, but an additional 1/8" (or more) may be added to C.

Closet Carriers_08.qxd 3/27/08 8:56 AM Page 19

20

CLOSET CARRIERSCLOSET CARRIERSCA

RRIE

RS

Adjustable Closet Carrier Options

(-24) OPTION, FOR FLOOR-MOUNTED BACK-OUTLET CHINA CLOSETS

This option adapts adjustable as well as other types of fittings for securing floor-mounted back-outlet China closets. Any adjustable fitting is adapted as shown in Illustration A. Other

types of fittings are provided with bosses to attach the closet securing studs at the correct dimensions for this type of closet. See Illustration B.

The options shown below illustrate and explain various optional carrier components. These options must be specified and installed when the typeof closet or installation dictates their use.

(-1) OPTION, TRU-SET POSITIONING FRAME (Siphon Jet Closets Only)

Made of high impact polystyrene, the TRU-SET Positioning Frame offers many

advantages to the plumbing contractor. The positioning frame is mounted on

the carrier studs at the time the carrier is being installed, thus it acts as a

guide and template, eliminating problems caused by normal dimensional

variations when the wall is being erected. Studs and adjustable extension are

set to the frame, eliminating further adjustment when the fixture is being

hung. Chances of bowl breakage are minimized since bowl is held the cor-

rect distance from finished wall.

NOTE: Sold only with JOSAM closet carriers.

(-VP) OPTION, VANDAL-PROOF TRIM

The JOSAM Vandal-Proof trim is designed to prevent tampering and possible damage to

the fixture caused by vandalism. The Vandal-Proof trim can be used in place of the regular

JOSAM cap nuts. Trim is installed using a hex key. After installation is complete, chrome

plated expansion plugs which match the nuts, snap into place minimizing the chances of

vandalism.

(-6) OPTION, SUPPLY PIPE SUPPORT

Support assembly attaches to an upper carrier mounting stud and securely holds water

supply pipe running to the flush valve. This hanger prevents movement of water

piping during and after construction, protecting piping as well as the flush valve. When

ordering, specify type of pipe to be supported.

ILLUSTRATION A ILLUSTRATION B

Closet Carriers_08.qxd 3/27/08 8:56 AM Page 20

21

CLOSET CARRIERSCLOSET CARRIERSCA

RRIERS

Closet Carrier Position Chart for Wheelchair FacilitiesEXPLANATION AND USE OF CHARTThe chart represents solutions for nine separate applications, each line being the solution for a different application. Notice that for every application,there is a solution using only standard carriers. Use of the 12000-35 carrier can be avoided in most situations. Column 1 represents a fixture mountedon a vertical stack fitting. Columns 2 through 8 represent the locations of additional fixtures mounted on horizontal fittings. Each column is dividedinto three sub-columns, identified as A, B, and C. The ll, l and p symbols show the types of carriers that can be used for either normal or highrough in that particular location. Blank spaces mean that the carrier cannot be used in that location. The far right-hand column shows the slope orpitch per foot of the horizontal drain line to the stack. Notice that lines 5 and 6 show a slope of 1/4 in. per foot. The chart applies toeither siphon jet or blowout fixtures, and should eliminate confusion about installations for the physically disabled.

EXAMPLE:A. Requirement: Plans call for rest rooms back-to-back, each with six water closets, one of which is to be high rough.

B. Solution: Because six fixtures are involved, refer to column 6, line 7. Note that a standard 12000 Carrier [sub-column B] can be used for thehigh rough fixture at the upstream end of the branch. The remaining five fixtures, all at normal rough, can be mounted on standard 12000 Carriersas shown in columns 1 through 5, sub-columns A.

Note that the standard 12000 Carrier can be used in a high rough position at the stack or at the upstream end of the horizontal branch,depending on the number of closets required, as shown in sub-columns B. Either of these locations is preferred for the high rough water closet.Thus, for most installations, the standard 12000 Carrier is suitable. However, if the high rough water closet cannot be so located, the12000-35 high rough Carrier can be used in almost any location, depending on the number of closets required. In this case it may be necessary toincrease the horizontal spacing between locations to some distance greater than 36 inches. If so, the above chart is no longer applicable.Furthermore, whenever the fixture arrangement for back-to-back water closets requires high rough on one side and normal rough on the otherside, the 12000-35 Carrier must be used on the high rough side.

For unusual requirements not covered by this chart, we suggest you contact your JOSAM Representative.

*NOTE: Even though specific construction requirements for the physically disabled may vary from one jurisdiction to another, those specified in American National Standard ANSIA117.1-1980 are generally accepted. In this standard, Section 4, Paragraph 4.16.3 states that the height of water closets shall be 17 to 19 in. to the top of the seat. This confirmsthe water closet rim height of 18 in. for the physically disabled, previously established in ANSI A112.19.2, which is a standard for vitreous China plumbing fixtures. In compliancewith these standards, the above selection chart has been developed using a 3 in. difference in elevation between normal rough fixtures [15 in. rim height] and high rough fixtures[18 in. rim height].

STACK HORIZONTAL CARRIER LOCATIONS SLOPE

LINE 1 2 3 4 5 6 7 8 PER

A B C A B C A B C A B C A B C A B C A B C A B C FOOT

1 ll l p 1/8 in.

2 ll l p ll p 1/8 in.

3 ll l p ll p ll p 1/8 in.

4 ll l p ll p ll p ll p 1/8 in.

5 ll p ll p ll p l p 1/4 in.

6 ll p ll ll p ll p l p 1/4 in.

7 ll p ll p ll p ll p ll p l p 1/8 in.

8 ll p ll ll p ll p ll p ll p l p 1/8 in.

9 ll p ll ll ll p ll p ll p ll p l p 1/8 in.

CLOSET CARRIER SELECTIONINSTALLATIONS FOR THE PHYSICALLY DISABLED

Based on 3 in. difference in elevation between normal and high rough fixtures,and on 36 inches between fixtures [horizontally]. See note below.*

A = ll = Normal rough with standard 12000 Series CarrierB = l = High rough with standard 12000 Series CarrierC =p = High rough with 12000-35 Series Carrier

Carriers ll and p are required for back-to-back mounting when one fixture is normal rough and the other is high rough.

Closet Carriers_08.qxd 3/27/08 8:56 AM Page 21

22

CLOSET CARRIERSCLOSET CARRIERSCA

RRIE

RS

Wheelchair Closet Carrier InstallationsAccommodations for the physically disabled who depend on wheelchairs for mobility are of prime importance and should be included in any build-ing where public toilet facilities are provided. Off-the-floor water closets are ideally suited for wheelchair use. In addition to the sanitation benefits,the elevation is not fixed as it is with the floor-mounted closets. By utilizing the JOSAM line of carriers and fittings, the wheelchair closet can belocated anywhere in a battery. See Carrier Selection Chart. The illustrations below show the wheelchair closet in various locations.

(-35) Option Carrier can be used with alladjustable fittings. When used with blowoutclosets over 12 1/2”, specify –M1358.

To the left is a possible installation utilizingthe –35 Option at the end of a battery ofstandard rough carriers.

The above shows an installation utilizing a JOSAM vertical fitting and carrier and a horizontal waste line with fittings and carriers. The horizontal fitting and carrier on the end show the (-35) high rough for wheelchair use.

The above shows an installation utilizing a standard JOSAM stack fit-ting with the carrier on this fitting roughed for wheelchair use. Withthis installation one to three horizontal fittings can be connected to the stack fitting.

Closet Carriers_08.qxd 3/27/08 8:56 AM Page 22

CLOSET CARRIERSCLOSET CARRIERS

23

CARRIERS

23

APPLICATIONFor wall-hung water closets where carrier fitting is not required.

SPECIFICATIONJOSAM 11001 Series coated cast iron universal pipe grip Closet Carrier with 4” pipeadapter, adjustable feet and finish hardware and trim to support siphon jet or blow-out wall-hung water closet. Waste piping and fitting provided by others.

11001 SERIES CARRIER WITH PIPE ADAPTER

38 LBS.

38 LBS.

APPLICATIONFor wall-hung water closets where carrier fitting is not required.

SPECIFICATIONJOSAM 11007 and 11008 Series coated cast iron universal pipe grip Closet Carrierwith 3” or 4” copper pipe adapter, adjustable feet and finish hardware and trim tosupport siphon jet or blow-out wall-hung water closet. Waste piping and fitting pro-vided by others.

11007 & 11008 SERIES CARRIER WITH COPPER PIPE ADAPTOR

Closet Carriers_08.qxd 3/27/08 8:56 AM Page 23

CLOSET CARRIERSCLOSET CARRIERS

24

DIM. SHOWN IS FOR SIPHON JET. BLOWOUT IS:11" MIN. & 16-1/2" MAX. 2” MIN. & 4” MAX.

RECOMMENDED ALL FEET BE SECURED TO FLOORWITH 1/2” BOLTS AND ANCHORS BY OTHERS.

FOR ROUGHING OVER 6" FOR SIPHON JET OR 12-1/2" FOR BLOWOUT, SPECIFY ON ORDER.

FOR DIM. SHORTER THAN 5-1/2" (1" MIN.) CUT EXT.SPECIFY –10 FOR LONGER EXT. (10-1/2" MAX.)

n r

t Product Illustration follows.

–PF Pylon Foot, Std.–OR O-Ring Carrier–SD Special-Duty 500 lb. Carrier

t –HS Hub & Spigot–AUX Auxiliary Inlet, 2”–VP Vandal-Proof Trim–1 Positioning Frame–6 Supply Pipe Support (Specify Type of Pipe)

OPTIONS & NOTES

12694 For use with Siphon Jet or Blowout Closets in No-Hub piping systems where back-to-back adjustable fittingwith horizontal flow is desired.APPLICATION:

100 LBS.

12674 & 12684

HORIZONTAL 4” NO-HUB, ADJUSTABLE, SINGLEFor use with Siphon Jet or Blowout Closets in No-Hub piping systems where single adjustable fitting withhorizontal flow is desired.APPLICATION:

60 LBS.

–10 ABS Extension, through 10-1/2" Wall–24 Carrier for Floor-Mounted, Back-Outlet China Bowls–30 Cast Iron Adjustable Extension with Connector–30–2 Cast Iron Adjustable Extension with Connector and Test Cap–32 Carrier for Wide Chase Installations–35 Closet Carrier for Wheelchair High Rough

t –58 Horizontal No-Hub Cast Long Barrel

12674 Left-Hand (Shown)12684 Right-Hand (Opposite)

Back-to-Back

HORIZONTAL 4” NO-HUB, ADJUSTABLE, BACK-TO-BACK

CARR

IERS

Closet Carriers_08.qxd 3/27/08 8:56 AM Page 24

CLOSET CARRIERSCLOSET CARRIERS

25

CARRIERS

82 LBS.

Single, Left-Hand, Hub & Spigot

12674-HS SERIESSingle, Right-Hand, Hub & Spigot

12684-HS SERIES

Back-to-Back, Hub & Spigot

12694-HS SERIESSingle, Left-Hand, No-Hub

12674-58 SERIES Long Barrel

Single, Right-Hand, No-Hub

12684-58 SERIES Long Barrel 12694-58 SERIES Long Barrel

RECOMMENDED ALL FEET BE SECURED TO FLOOR WITH 1/2” BOLTS AND ANCHORS BY OTHERS. FOR DIM. SHORTER THAN 5-1/2" (1" MIN.) CUT EXT. SPECIFY –10 FOR LONGER EXT. (10-1/2" MAX.)n r

Back-to-Back, No-Hub

65 LBS.

112 LBS.

125 LBS.

65 LBS.

82 LBS.

Closet Carriers_08.qxd 4/30/08 8:56 AM Page 25

CLOSET CARRIERSCLOSET CARRIERS

26

DIM. SHOWN IS FOR SIPHON JET. BLOWOUT IS:11" MIN. & 16-1/2" MAX.

RECOMMENDED ALL FEET BE SECURED TO FLOORWITH 1/2” BOLTS AND ANCHORS BY OTHERS.

FOR ROUGHING OVER 6" FOR SIPHON JET OR 12-1/2" FOR BLOWOUT, SPECIFY ON ORDER.

FOR DIM. SHORTER THAN 5-1/2" (1" MIN.) CUT EXT.SPECIFY –10 FOR LONGER EXT. (10-1/2" MAX.)

n r

t Product Illustration follows.

–PF Pylon Foot, Std.–OR O-Ring Carrier–SD Special-Duty 500 lb. Carrier

t –HS Hub & Spigott –LH4 Left-Hand 4" No-Hub Brancht –HLH4 Left-Hand 4" Hub Brancht –RH4 Right-Hand 4" No-Hub Brancht –HRH4 Right-Hand 4" Hub Brancht –D4 Double 4" No-Hub Branchest –HD4 Double 4" Hub Branches

–VP Vandal-Proof Trim–1 Positioning Frame

–6 Supply Pipe Support (Specify Type of Pipe)–10 ABS Extension, through 10-1/2" Wall–24 Carrier for Floor-Mounted, Back-Outlet China Bowls–30 Cast Iron Adjustable Extension with Connector–30–2 Cast Iron Adjustable Extension with Connector and Test Cap–32 Carrier for Wide Chase Installations–35 Closet Carrier for Wheelchair High Rough–49 No-Hub High Auxiliary Inlet, Under Vent–50 No-Hub High Auxiliary Inlet, Opposite Vent–53 Threaded High Auxiliary Inlet, Under Vent–54 Threaded High Auxiliary Inlet, Opposite Vent

12704

VERTICAL 4” NO-HUB, ADJUSTABLE, SINGLEFor use with Siphon Jet or Blowout Closets in No-Hub piping systems where back-to-back adjustable fitting withvertical flow is desired.APPLICATION:

Single Fitting, On Stack, Left-Hand 2” Vent

72 LBS. OPTIONS N/A: -LH4, -RH4, -D4

OPTIONS

83 LBS.

Single, Left-Hand 2" Vent, Hub & Spigot

12704-HS SERIES 12704-LH4 SERIESSingle, Left-Hand 4" Branch, Left-Hand 2" Vent

71 LBS. OPTIONS N/A: -49, -53

CARR

IERS

Closet Carriers_08.qxd 3/27/08 8:56 AM Page 26

CLOSET CARRIERSCLOSET CARRIERS

27

CARRIERS

Single, Left-Hand Branch, Left-Hand 2” Vent

12704-HS-HLH4 SERIESSingle, Right-Hand 4” Branch, Left-Hand 2” Vent

12704-RH4 SERIES

Single, Right-Hand Branch, Left-Hand 2” Vent

12704-HS-HRH4 SERIESSingle, Two 4” Branches, Left-Hand 2” Vent

12704-D4 SERIES

Single, Two 4” Branches, Left-Hand 2” Vent

12704-HS-HD4 SERIES

RECOMMENDED ALL FEET BE SECURED TO FLOOR WITH 1/2” BOLTS AND ANCHORS BY OTHERS. FOR DIM. SHORTER THAN 5-1/2" (1" MIN.) CUT EXT. SPECIFY –10 FOR LONGER EXT. (10-1/2" MAX.)n r

84 LBS. OPTIONS N/A: -49, -53 71 LBS. OPTIONS N/A: -50, -54

84 LBS. OPTIONS N/A: -50, -54

86 LBS. OPTIONS N/A: -49, -50, -53, -54

70 LBS. OPTIONS N/A: -49, -50, -53, -54

Closet Carriers_08.qxd 4/17/08 1:05 PM Page 27

CLOSET CARRIERSCLOSET CARRIERS

28

DIM. SHOWN IS FOR SIPHON JET. BLOWOUT IS:11" MIN. & 16-1/2" MAX.

RECOMMENDED ALL FEET BE SECURED TO FLOORWITH 1/2” BOLTS AND ANCHORS BY OTHERS.

FOR ROUGHING OVER 6" FOR SIPHON JET OR 12-1/2" FOR BLOWOUT, SPECIFY ON ORDER.

FOR DIM. SHORTER THAN 5-1/2" (1" MIN.) CUT EXT.SPECIFY –10 FOR LONGER EXT. (10-1/2" MAX.)

n r

t Product Illustration follows.

–6 Supply Pipe Support (Specify Type of Pipe)–10 ABS Extension, through 10-1/2" Wall–24 Carrier for Floor-Mounted, Back-Outlet China Bowls–30 Cast Iron Adjustable Extension with Connector–30–2 Cast Iron Adjustable Extension with Connector and Test Cap–32 Carrier for Wide Chase Installations–35 Closet Carrier for Wheelchair High Rough–49 No-Hub High Auxiliary Inlet, Under Vent–50 No-Hub High Auxiliary Inlet, Opposite Vent–53 Threaded High Auxiliary Inlet, Under Vent–54 Threaded High Auxiliary Inlet, Opposite Vent

12714

VERTICAL 4” NO-HUB, ADJUSTABLE, SINGLEFor use with Siphon Jet or Blowout Closets in No-Hub piping systems where single adjustable fitting withvertical flow is desired.APPLICATION:

Single Fitting, On Stack, Right-Hand 2” Vent

72 LBS.

OPTIONS

Single, Right-Hand 2" Vent, Hub & Spigot

12714-HS SERIES 12714-RH4 SERIESSingle, Right-Hand 4" Branch, Right-Hand 2" Vent

83 LBS. OPTIONS N/A: -LH4, -RH4, D4 71 LBS. OPTIONS N/A: -49, -53

–PF Pylon Foot, Std.–OR O-Ring Carrier–SD Special-Duty 500 lb. Carrier

t –HS Hub & Spigott –LH4 Left-Hand 4" No-Hub Brancht –HLH4 Left-Hand 4" Hub Brancht –RH4 Right-Hand 4" No-Hub Brancht –HRH4 Right-Hand 4" Hub Brancht –D4 Double 4" No-Hub Branchest –HD4 Double 4" Hub Branches

–VP Vandal-Proof Trim–1 Positioning Frame

CARR

IERS

Closet Carriers_08.qxd 4/28/08 12:05 PM Page 28

CLOSET CARRIERSCLOSET CARRIERS

29

CARRIERS

86 LBS. OPTIONS N/A: -49, -50, -53, -54

Single, Right-Hand Branch, Right-Hand 2" Vent

12714-HS-HRH4 SERIESSingle, Left-Hand 4"Branch, Right-Hand 2" Vent

12714-LH4 SERIES

Single, Left-Hand Branch, Right-Hand 2" Vent

12714-HS-HLH4 SERIESSingle, Two 4" Branches, Right-Hand 2" Vent

12714-D4 SERIES

Single, Two 4" Branches, Right-Hand 2" Vent

12714-HS-HD4 SERIES

RECOMMENDED ALL FEET BE SECURED TO FLOOR WITH 1/2” BOLTS AND ANCHORS BY OTHERS. FOR DIM. SHORTER THAN 5-1/2" (1" MIN.) CUT EXT. SPECIFY –10 FOR LONGER EXT. (10-1/2" MAX.)n r

84 LBS. OPTIONS N/A: -49, -53

84 LBS. OPTIONS N/A: -50, -54

71 LBS. OPTIONS N/A: -50, -54

70 LBS. OPTIONS N/A: -49, -50, -53, -54

Closet Carriers_08.qxd 3/27/08 8:57 AM Page 29

CLOSET CARRIERSCLOSET CARRIERS

30

DIM. SHOWN IS FOR SIPHON JET. BLOWOUT IS:11" MIN. & 16-1/2" MAX.

RECOMMENDED ALL FEET BE SECURED TO FLOORWITH 1/2” BOLTS AND ANCHORS BY OTHERS.

FOR ROUGHING OVER 6" FOR SIPHON JET OR 12-1/2" FOR BLOWOUT, SPECIFY ON ORDER.

FOR DIM. SHORTER THAN 5-1/2" (1" MIN.) CUT EXT.SPECIFY –10 FOR LONGER EXT. (10-1/2" MAX.)

n r

t Product Illustration follows.

–PF Pylon Foot, Std.–OR O-Ring Carrier–SD Special-Duty 500 lb. Carrier

t –HS Hub & Spigott –D4 Double 4" No-Hub Branchest –HD4 Double 4" Hub Branchest –VS4 Vent Side 4" No-Hub Brancht –OS4 Opposite Vent 4" No-Hub Brancht –HVS4 Vent Side 4" Hub Branch

–VP Vandal-Proof Trim–1 Positioning Frame

–6 Supply Pipe Support (Specify Type of Pipe)–10 ABS Extension, through 10-1/2" Wall–24 Carrier for Floor-Mounted, Back-Outlet China Bowls–30 Cast Iron Adjustable Extension with Connector–30–2 Cast Iron Adjustable Extension with Connector and Test Cap–32 Carrier for Wide Chase Installations–35 Closet Carrier for Wheelchair High Rough–49 No-Hub High Auxiliary Inlet, Under Vent–50 No-Hub High Auxiliary Inlet, Opposite Vent–53 Threaded High Auxiliary Inlet, Under Vent–54 Threaded High Auxiliary Inlet, Opposite Vent

12724

VERTICAL 4” NO-HUB, ADJUSTABLE, BACK-TO-BACKFor use with Siphon Jet or Blowout Closets in No-Hub piping systems where back-to-back adjustable fittingwith vertical flow is desired.APPLICATION:

Back-to-Back Fitting, On Stack, 2” Vent

117 LBS. OPTIONS N/A: -HD4, -HVS4.

OPTIONS & NOTES

CARR

IERS

Closet Carriers_08.qxd 3/27/08 8:57 AM Page 30

CLOSET CARRIERSCLOSET CARRIERS

31

CARRIERS

r

115 LBS. OPTIONS N/A: -49, -50, -53, -54

Back-to-Back, 2" Vent

12724-HS SERIESBack-to-Back, 4" Branch, 2" Vent Same Side

12724-VS4 SERIES

Back-to-Back, 4" Branch, 2" Vent Opposite Side

12724-OS4 SERIESBack-to-Back, Single Branch, 2" Vent

12724-HS-HVS4 SERIES

Back-to-Back, Two 4" Branches, 2" Vent

12724-D4 SERIES 12724-HS-HD4 SERIESBack-to-Back, Two 4" Branches, 2" Vent

31

129 LBS. OPTIONS N/A: -D4, -VS4, -OS4

116 LBS. OPTIONS N/A: -50, -54

131 LBS. OPTIONS N/A: -49, -50, -53, -54

116 LBS. OPTIONS N/A: -49, -53

118 LBS. OPTIONS N/A: -49, -53

FOR DIM. SHORTER THAN 5-1/2" (1" MIN.) CUT EXT. SPECIFY –10 FOR LONGER EXT. (10-1/2" MAX.)

Closet Carriers_08.qxd 4/22/08 6:20 PM Page 31

CLOSET CARRIERSCLOSET CARRIERS

32

DIM. SHOWN IS FOR SIPHON JET. BLOWOUT IS:11" MIN. & 16-1/2" MAX.

RECOMMENDED ALL FEET BE SECURED TO FLOORWITH 1/2” BOLTS AND ANCHORS BY OTHERS.

FOR ROUGHING OVER 6" FOR SIPHON JET OR 12-1/2" FOR BLOWOUT, SPECIFY ON ORDER.

FOR DIM. SHORTER THAN 3-3/4" (1" MIN.) CUT EXT.n r

14044 For use with Siphon Jet or Blowout Closets in Hub and Spigot piping systems where back-to-back compactoffset fitting with vertical flow is desired.APPLICATION:

120 LBS.

14004 & 14024

VERTICAL 4” HUB & SPIGOT, CLOSE, SINGLEFor use with Siphon Jet or Blowout Closets in Hub and Spigot piping systems where single compact offsetfitting with vertical flow is desired.APPLICATION:

14004 Single Fitting, Left-Hand Offset, Left-Hand 2” Vent (Shown)14024 Single Fitting, Right-Hand Offset, Right-Hand 2” Vent (Opposite)

Back-to-Back Fitting, Offset, 2” Vent

70 LBS.

VERTICAL 4” HUB & SPIGOT, CLOSE, BACK-TO-BACK

OPTIONS & NOTES–VP Vandal-Proof Trim–1 Positioning Frame–6 Supply Pipe Support (Specify Type of Pipe)–21 Hanger Type Closet Adapter–54 Threaded Auxiliary Inlet, Opposite Vent

CARR

IERS

Closet Carriers_08.qxd 4/30/08 8:56 AM Page 32

CLOSET CARRIERSCLOSET CARRIERS

33

DIM. SHOWN IS FOR SIPHON JET. BLOWOUT IS:11" MIN. & 16-1/2" MAX.

RECOMMENDED ALL FEET BE SECURED TO FLOORWITH 1/2” BOLTS AND ANCHORS BY OTHERS.

FOR ROUGHING OVER 6" FOR SIPHON JET OR 12-1/2" FOR BLOWOUT, SPECIFY ON ORDER.

FOR DIM. SHORTER THAN 5-1/2" (1" MIN.) CUT EXT.n r

14104 For use with Siphon Jet or Blowout Closets in Hub and Spigot piping systems where single compact on-stackfitting with 2" vent and vertical flow is desired.APPLICATION:

60 LBS.

14064

VERTICAL 4” HUB & SPIGOT, CLOSE, SINGLEFor use with Siphon Jet or Blowout Closets in Hub and Spigot piping systems where single compact on-stackfitting with 4" vent and vertical flow is desired.APPLICATION:

Single Fitting, On Stack, 4” Vent

Single Fitting, On Stack, 2” Vent

63 LBS.

VERTICAL 4” HUB & SPIGOT, CLOSE, SINGLE

OPTIONS & NOTES–SD Special Duty 500 lb. Carrier–VP Vandal-Proof Trim–1 Positioning Frame–6 Supply Pipe Support (Specify Type of Pipe)–45 Threaded Left-Hand Auxiliary Inlet–46 Threaded Right-Hand Auxiliary Inlet

CARRIERS

Closet Carriers_08.qxd 4/28/08 12:06 PM Page 33

CLOSET CARRIERSCLOSET CARRIERS

34

DIM. SHOWN IS FOR SIPHON JET. BLOWOUT IS:11" MIN. & 16-1/2" MAX.

RECOMMENDED ALL FEET BE SECURED TO FLOORWITH 1/2” BOLTS AND ANCHORS BY OTHERS.

FOR ROUGHING OVER 6" FOR SIPHON JET OR 12-1/2" FOR BLOWOUT, SPECIFY ON ORDER.

FOR DIM. SHORTER THAN 5-1/2" (1" MIN.) CUT EXT.SPECIFY –10 FOR LONGER EXT. (10-1/2" MAX.)

n r

–SD Special Duty 500 lb. Carrier–VP Vandal-Proof Trim–1 Positioning Frame–6 Supply Pipe Support (Specify Type of Pipe)–10 ABS Extension, through 10-1/2" Wall

–24 Carrier for Floor-Mounted, Back-Outlet China Bowls–30 Cast Iron Adjustable Extension with Connector–30–2 Cast Iron Adjustable Extension with Connector and Test Cap Assembly–50 No-Hub High Auxiliary Inlet, Opposite Vent–54 Threaded High Auxiliary Inlet, Opposite Vent

14444 For use with Siphon Jet or Blowout Closets in No-Hub piping systems where back-to-back compact offsetfitting with 2" auxiliary inlet vertical flow is desired.APPLICATION:

90 LBS.

14404 & 14424

VERTICAL 4” NO-HUB, CLOSE, SINGLEFor use with Siphon Jet or Blowout Closets in No-Hub piping systems where single compact offset fittingwith 2"auxiliary inlet vertical flow is desired.APPLICATION:

14404 Single Fitting, Left-Hand Offset, Left-Hand 2 ” Vent (Shown)14424 Single Fitting, Right-Hand Offset, Right-Hand 2 ” Vent (Opposite)

Back-to-Back Fitting, Offset, 2” Vent

60 LBS.

VERTICAL 4” NO-HUB, CLOSE, BACK-TO-BACK

OPTIONS & NOTES

CARR

IERS

Closet Carriers_08.qxd 4/18/08 1:09 PM Page 34

CLOSET CARRIERSCLOSET CARRIERS

35

DIM. SHOWN IS FOR SIPHON JET. BLOWOUT IS:11" MIN. & 16-1/2" MAX.

RECOMMENDED ALL FEET BE SECURED TO FLOORWITH 1/2” BOLTS AND ANCHORS BY OTHERS.

FOR ROUGHING OVER 6" FOR SIPHON JET OR 12-1/2" FOR BLOWOUT, SPECIFY ON ORDER.

FOR DIM. SHORTER THAN 5-1/2" (1" MIN.) CUT EXT.SPECIFY –10 FOR LONGER EXT. (10-1/2" MAX.)

r

–24 Carrier for Floor-Mounted, Back-Outlet China Bowls–30 Cast Iron Adjustable Extension with Connector–30–2 Cast Iron Adjustable Extension with Connector and Test Cap Assembly–45 Threaded Left-Hand Auxiliary Inlet–46 Threaded Right-Hand Auxiliary Inlet

14484 For use with Siphon Jet Closets in No-Hub piping systems where back-to-back compact on-stack fitting withvertical flow is desired.APPLICATION:

82 LBS.

14464

VERTICAL 4” NO-HUB, CLOSE, SINGLEFor use with Siphon Jet or Blowout Closets in No-Hub piping systems where single compact on-stack fittingwith 4" vent and vertical flow is desired.APPLICATION:

Single Fitting, On Stack, 4” Vent

Back-to-Back Fitting, 4” Vent, for Siphon Jet Closets Only

52 LBS.

VERTICAL 4” NO-HUB, CLOSE, BACK-TO-BACK

OPTIONS & NOTES–SD Special Duty 500 lb. Carrier–VP Vandal-Proof Trim–1 Positioning Frame–6 Supply Pipe Support (Specify Type of Pipe)–10 ABS Extension, through 10-1/2" Wall

n

CARRIERS

Closet Carriers_08.qxd 4/28/08 12:06 PM Page 35

CLOSET CARRIERSCLOSET CARRIERS

36

DIM. SHOWN IS FOR SIPHON JET. BLOWOUT IS:11" MIN. & 16-1/2" MAX.

RECOMMENDED ALL FEET BE SECURED TO FLOORWITH 1/2” BOLTS AND ANCHORS BY OTHERS.

FOR ROUGHING OVER 6" FOR SIPHON JET OR 12-1/2" FOR BLOWOUT, SPECIFY ON ORDER.

FOR DIM. SHORTER THAN 5-1/2" (1" MIN.) CUT EXT.SPECIFY –10 FOR LONGER EXT. (10-1/2" MAX.)

n r

–SD Special Duty 500 lb. Carrier–VP Vandal-Proof Trim–1 Positioning Fram–6 Supply Pipe Support (Specify Type of Pipe)–10 ABS Extension, through 10-1/2" Wall

–24 Carrier for Floor-Mounted, Back-Outlet China Bowls–30 Cast Iron Adjustable Extension with Connector–30–2 Cast Iron Adjustable Extension with Connector and Test Cap Assembly–45 Threaded Left-Hand Auxiliary Inlet–46 Threaded Right-Hand Auxiliary Inlet

14504

VERTICAL 4” NO-HUB, CLOSE, SINGLEFor use with Siphon Jet or Blowout Closets in No-Hub piping systems where single compact on-stack fittingwith 2" vent and vertical flow is desired.APPLICATION:

Single Fitting, On Stack, 2” Vent

82 LBS.

OPTIONS & NOTES

CARR

IERS

Closet Carriers_08.qxd 4/18/08 1:09 PM Page 36

CLOSET CARRIERSCLOSET CARRIERS

37

Double Waste Fitting On Stack with Vent & Carriers

DIM. SHOWN IS FOR SIPHON JET. BLOWOUT IS:11" MIN. & 16-1/2" MAX.

RECOMMENDED ALL FEET BE SECURED TO FLOORWITH 1/2” BOLTS AND ANCHORS BY OTHERS.

FOR DIM. SHORTER THAN 5-1/2" (1-3/4" MIN.) CUTEXT. SPECIFY –10 FOR LONGER EXT. (10-1/2" MAX.)

r

APPLICATIONS SERIES15964 15984

–26 Fitting Anchor Foot X X–30 Cast Iron Adjustable Extension with Connector X ––30–2 Cast Iron Adjustable Ext. w/Connector & Test Cap Assy. X ––49 No-Hub High Auxiliary Inlet, Under Vent X X–54 Threaded High Auxiliary Inlet, Opposite Vent X X

15984

For use with Siphon Jet or Blowout Closets in No-Hub piping systems where 90-degree double waste fittingwith vent, auxiliary inlet and vertical flow is desired such as in prisons. Fitting only, carrier trim by others.APPLICATION:

JOSAM 15984 Series coated cast iron vertical 4" no-hub double waste 90º Stack Fitting with 4" no-hubcloset branches and 2" no-hub vent.SPECIFICATION:

26 LBS.

15964

VERTICAL NO-HUB, 90° INSTITUTIONAL FITTINGFor use with Siphon Jet or Blowout Closets in No-Hub piping systems where 90-degree double waste fittingwith vent, auxiliary inlet and vertical flow is desired such as in prisons.APPLICATION:

JOSAM 15964 Series coated cast iron vertical 4" no-hub double waste 90º Stack Fitting with 4" closetbranches, 2" no-hub vent, with close closet carriers invertible for siphon jet or blowout closets, ABS extensionswith integral test caps, buttress feet, plated hardware and fixture gaskets.

SPECIFICATION:

Double Waste Fitting On Stack, No-Hub Branches, 2” Vent

90 LBS.

VERTICAL NO-HUB, 90° INSTITUTIONAL FITTING

OPTIONS & NOTESAPPLICATIONS SERIES

15964 15984–VP Vandal-Proof Trim X ––1 Positioning Frame X ––6 Supply Pipe Support (Specify Type of Pipe) X ––10 ABS Extension, through 10-1/2" Wall X ––24 Carrier for Floor-Mounted, Back-Outlet China Bowls X –

n

CARRIERS

Closet Carriers_08.qxd 3/27/08 8:57 AM Page 37

CLOSET CARRIERSCLOSET CARRIERS

38

THIS CARRIER CAN ALSO BE USED WITH A 4 X 4 X 3 TEE.RECOMMENDED ALL FEET BE SECURED TO FLOORWITH 1/2” BOLTS AND ANCHORS BY OTHERS.

r

–VP Vandal-Proof Trim–1 Positioning Frame–6 Supply Pipe Support (Specify Type of Pipe)–13 ABS Extension–21 Hanger Type Closet Adapter

16123

FLOOR-MOUNT, PVC ADAPTER TYPEFor use with Siphon Jet Closets only in PVC piping systems where a single compact carrier with vertical flowis desired and a 3" PVC fitting is to be furnished by others.APPLICATION:

JOSAM 16123 Series coated cast iron single Commercial Closet Carrier and 3" PVC plastic fitting adapterwith extension and chrome plated trim.SPECIFICATION:

Single Fitting, On Stack, Adapter Type for PVC Plastic Pipe for Siphon Jet Closets Only

35 LBS.

OPTIONS & NOTES

CARR

IERS

Closet Carriers_08.qxd 3/27/08 8:57 AM Page 38

39

FIXTURE CARRIERSFIXTURE CARRIERSCA

RRIERS

17380 -VP -10

Series No.Option, Vandal-Proof TrimOption, Hardware for Thicker Walls

How To Order Lavatory Carriers

EXAMPLE: Concealed Arm Carrier Series No. 17100

17100 -10 -75

Series No.Option, Extension Sleeves Longer than StandardOption, 2" Chrome-Plated Escutcheons, 2 Per Fixture

To order specify Series Number and use suffix numbers to indicate desired options.

EXAMPLE: Exposed Arm Carrier Series No. 17380

Types of Carriers • Ordering Information

LAVATORY CARRIERS

For supporting lavatories with or without arms.

1. Quantity.2. JOSAM series number.3. Fixture manufacturer, model number, name of fixture and size.

SINK CARRIERS

For supporting sinks or slab shelves.1. Quantity.2. JOSAM series number.3. Fixture manufacturer, model number, name of fixture and size.

URINAL CARRIERS

For supporting off-the-floor urinals.1. Quantity.2. JOSAM series number.3. Fixture manufacturer and model number.

WATER COOLER CARRIERS

For supporting off-the-floor water coolers.1. Quantity.2. JOSAM series number.3. Fixture manufacturer and model number.

HOSPITAL FIXTURECARRIERS

For supporting hospital sinks or lavatories with knee action valves.

1. Quantity.2. JOSAM series number.3. Fixture manufacturer, model number, name of fixture and size.4. Knee action valve, if used, give manufacturer and model number.

PLATE TYPE CARRIERS

Multipurpose carriers for supporting Lavatory, Sink, Urinal,Water Cooler and Hospital Fixtures.

1. Quantity.2. JOSAM series number.3. Fixture manufacturer, model number, name of fixture and size.

Fixture Carriers 08.qxd 3/27/08 11:46 AM Page 39

40

FIXTURE CARRIERS • Pictorial Selection GuideFIXTURE CARRIERS • Pictorial Selection GuideCA

RRIE

RS

FLOOR-MOUNTED17100Single

Page 46

17100-BBBack-to-Back

Page 46

17380Single, Acid-Resisting Arms

Page 48

17380-BBBack-to-Back

Page 49

17380-HDSingle, Heavy-Duty Acid-Resisting Arms

Page 49

17380-BB-HDBack-to-Back, Heavy-Duty

Page 49

FLOOR-MOUNTED • Hanger Plate Type17550Single

Page 52

17550-BBBack-to-Back

Page 52

17550-URUrinal Carrier

Page 53

17550-CLCorner Lavatory Carrier

Page 53

17550-WCWater Cooler Carrier

Page 53

17550-WCBLWater Cooler Bi-Level Carrier

Page 53

FLOOR-MOUNTED • Hanger & Bearing Plate Type17560Single

Page 54

17560-BBBack-to-Back

Page 54

17560-URUrinal Carrier

Page 55

17560-WCWater Cooler Carrier

Page 55

17560-WCBLWater Cooler Bi-Level Carrier

Page 55

Fixture Carriers 08.qxd 3/27/08 11:46 AM Page 40

41

FIXTURE CARRIERS • Pictorial Selection GuideFIXTURE CARRIERS • Pictorial Selection GuideCA

RRIERS

FLOOR-MOUNTED • Heavy-Duty Sink Carriers ALIGNMENT TOOL17720Hanger Plate, Exposed Acid-Resisting Arms

Page 58

17720-66Hanger Plate

Page 58

17730Support PlatesAdjustable Coupling

Page 59

17735Support Plates,Adjustable Coupling & Fitting

Page 59

17000Reusable Alignment Tool

Page 45

WALL-MOUNTED • Concealed Arms17120

Page 46

17120-10Extension Sleeves Longer than Std.

Page 47

17120-BPBack Plate

Page 47

17120-MMBMovable Mounting Brackets

Page 47

17125

Page 48

WALL-MOUNTED • Hanger Plate Type17590

Page 56

17590-DPDouble Plate

Page 56

17590-URUrinal Carrier

Page 57

17590-UR-DPUrinal Carrier with Double Plates

Page 57

WALL-MOUNTED • Exposed Arms17390

Page 50

17390-BPBack Plates

Page 50

17405

Page 51

Fixture Carriers 08.qxd 3/27/08 11:46 AM Page 41

42

FIXTURE CARRIERSFIXTURE CARRIERSCA

RRIE

RS

Concealed Arms UNITRON® II FeaturesJOSAM concealed arm Lavatory Carriers secure and support lavatories by means of cast iron arms with leveling and securing devices. Byvirtue of their design, they accommodate all types of lavatories punched for concealed arms. The cast iron arms are furnished as standardin three different lengths. The leveling and securing methods are the same for each arm length. After the carrier is installed and the wallscompleted, the sleeve and arm assembly is adjusted and installation of the lavatory is made by sliding it over the arms, leveling it throughthe access holes provided and then securely locking it in place with the LAVALOC® Securing Device.

HEAVY-DUTY INVERTIBLE HEADERSThe heavy-duty cast iron invertible headers supplied withJOSAM floor-mounted carrierscan be installed as shown orinverted and installed on the outside of the upright. The tierod is secured in place againstthe upright by the header,eliminating need for set screws.

HEAVY-DUTY WELDED FEETThe rectangular structural steel uprights are furnished with welded feet designed for use in today’s modern drywall construction. They must be bolted to the floor. Recommend 1/2”bolts by others.

RECTANGULAR STRUCTURALUPRIGHTS Josam has selected heavy-dutystructural steel uprights as thestandard for floor-mounted carriers. These uprights are narrow, for use in drywall construction, yet will supportmore weight than the round tubular uprights.

Today’s thin-wall construction demands that the carrier support the fixture completely independent of the wall construction, whether it is a lavatory, sink, urinal or water cooler. Due to the rectangular structural shape of the uprights and the welded feet, deflection is kept to a minimum,protecting the fixtures as well as the finished wall surface, thus eliminating the need for any alternate steadying methods. It is recommended, with all JOSAM carriers, that the feet be securely bolted to the floor for proper support. Rectangular structural uprights with welded feet are furnishedwith all floor-mounted JOSAM concealed, exposed arm or plate type carriers as standard, therefore there is no additional charge for this feature.

17100 SERIES CONCEALED ARM LAVATORY CARRIER SHOWN SUPPORTING A 300 POUND LOAD ON A WHEELCHAIR LAVATORY

Standard Plate FeaturesJOSAM, after testing and studyingmany alternates for plate type carriers,has designed and developed a standard hanger support and bearingplate, that can accommodate morethan 300 various fixtures.

A complete, easy to use "StandardPlate Application Manual" is includedwith every carrier. This manual givesthe various plate dimensions requiredfor a complete installation.

STANDARD PLATE

HEAVY-DUTY"U" BOLTS

STRUCTURALUPRIGHTS

Fixture Carriers 08.qxd 3/27/08 11:46 AM Page 42

43

FIXTURE CARRIERSFIXTURE CARRIERSCA

RRIERS

CONCEALED TYPE LAVATORY CARRIER

The drawings on this page show the relationship between mating parts of carriers covered in this section.

Concealed Arms Features

1. Tandem keepers in slots on the arm permit positioning of levelingscrews on the job to suit punchings of any lavatory specified.

2. Screws in keepers can then easily be moved up or down to level the lavatory.

3. The securing lock device is positioned on the arm and tightensagainst the fixture to hold it rigidly in place.

4. The sleeve can be adjusted to suit various wall thicknesses.

5. The final setting of the arm out from the wall can be made from the face of the finished wall after the wall is built.

6. The set screws are easily accessible for quicker adjustment.7. Arm with the locking device, tandem keepers, and adjustable

sleeve, is completely assembled at the factory.8. Hardware is plated to prevent corrosion.

Detail of securing method forconcealed arm carrier.

Detail of parts of concealed arm carrier in or behind finished wall.

Detail of leveling arrangementfor concealed arm carrier.

Detail of parts of concealed arm carrier.

Parts & Details Lavatory, Sink & Urinal Carriers

Fixture Carriers 08.qxd 3/27/08 11:46 AM Page 43

44

FIXTURE CARRIERSFIXTURE CARRIERSCA

RRIE

RS

(-60) OPTION, VALVE PLATE ON UPRIGHTallows carriers with uprights to be converted to support both hospitallavatories and knee or foot operated valves supplying these lavatories.Valve plate is securely fastened to upright and is supplied with hard-ware and chrome-plated trim for mounting valve.

(-66) OPTION, SPLIT HEADER FOR STAINLESS STEEL ARMSIn many cases arms are supplied by the manufacturers of stainless steelfixtures. The mounting hole spacing in the back of the arm (Y Dim.)varies widely by sink and manufacturer. The -66 split header is adjustableto allow for the mounting of this type of sink and arm combination.

(-67) OPTION, CONCEALED ARM WHEELCHAIR LAVATORYMost major fixture manufacturers offer an elongated lavatory especiallydesigned for the wheelchair user. This lavatory requires a special typecarrier which roughs the lavatory higher than normal and also willsupport the long extension of china.

OptionsThe options shown below illustrate and explain various optional carrier components. These options must be specified

and installed when the type of construction or fixture dictates their use. See specific series for available options.

(-10) OPTION, EXTENSION FOR THICK WALLSThis option provides the extension hardware required for mountingfixtures when the wall thickness (T Dim.) is greater than the maxi-mum thickness shown on drawing. Specify T Dim. when ordering this option.

(-75) OPTION, 2” ESCUTCHEONSprovide manufacturers’ specified distance of 2”from finished wall to back of a slab type lavato-ry to prevent water from deteriorating finishedwall when concealed arms are used. Furnishedin polished chrome.

(-76) OPTION, 4” ESCUTCHEONSpermit a 4” dimension between finished walland fixture when specification or designrequires. Used on concealed arms to preventwater from deteriorating finished wall.Furnished in polished chrome.

(-77) OPTION, 6” ESCUTCHEONSdesigned for slab type lavatories for wheelchairpatients when concealed arms are used, toprevent water from deteriorating finished walland provide space needed to accommodate awheelchair. Furnished in polished chrome.

Fixture Carriers 08.qxd 3/27/08 11:46 AM Page 44

45

FIXTURE CARRIERSFIXTURE CARRIERSReplacement Assembly Numbers For Concealed Arms

Description No. Required Part No.

ARM ASSEMBLIES17100-201 Arm Assembly 16.75” 2 Per Fixture 56627017100-202 Arm Assembly 19.5” 2 Per Fixture 566290T17100-203 Arm Assembly 22” 2 Per Fixture 566310T

SLEEVE ASSEMBLIES17100 Sleeve Assembly 4" 2 Per Fixture 566460T17100 Sleeve Assembly 6.5" 2 Per Fixture 566340T17100 Sleeve Assembly 8.5" 2 Per Fixture 56651017100 Sleeve Assembly 10.5" 2 Per Fixture 566350T

ESCUTCHEONSEscutcheon Pack 2" Option –75 1 Pack Per Fixture 566226Escutcheon Pack 4" Option –76 1 Pack Per Fixture 566222

MISCELLANEOUS PARTS17100 Fixture Locking Device 1 Per Arm 56626217100 Leveling Device Assembly 2 Per Arm 56626317100-201 Hardware Pack 1 Per Fixture 566232T

Description No. Required Part No.

REUSABLE ALIGNMENT TOOL SERIES 17000

Features

• Used with Josam Floor-Mounted Fixture Carriers with uprights; concealed and exposed arm type, plate-type.

• Reusable bracket is less expensive than other one-piece pre-fab carriers.

• No obstruction for vertical water supply and waste piping.

• Movable uprights allow adjustment to meet all job-site conditions

• Carriers remain in standard packaging; no over-sized boxes required.

Instructions

1. Determine Upright Centers;For Concealed and Exposed Arm Carriers, Add 4” to the arm center.Consult carrier rough-in chart for upright centers on plate-type carriers

2. Set adjustable bracket to appropriate locating position.

3. Attach 17000 Alignment Tool at the bottom of both uprights.

4. Secure uprights to floor with 1/2” bolts (by others).

5. Remove reusable alignment tool and attach to the top of the uprights andset tie-rod or plate position.

Alignment Tool SettingUpright Spacing at Tie-Rod

Alignment Tool Setting UprightSpacing at Floor

Slot for Positioning Adjustable Bracket

Adjustable Bracket

Fixed Bracket2 LBS

CARRIERS

Fixture Carriers 08.qxd 4/29/08 10:42 AM Page 45

APPLICATIONFor use with lavatories punched for concealed arms where thin wall constructiondemands uprights that support the fixture completely independent of the wall.

SPECIFICATIONJOSAM 17100 Series floor-mounted single Lavatory Carrier with concealed arms,leveling and securing screws, structural uprights and welded feet.

FIXTURE CARRIERSFIXTURE CARRIERS

46

VARIABLE – DEPENDS ON FIXTURE.

STD. ADJUSTABLE SLEEVE 4”

51 LBS

43 LBS

16 LBS

t Product Illustration follows.

17100 SERIES FLOOR-MOUNT, Concealed ArmsREUSABLE ALIGNMENT TOOLAVAILABLE. SEE PAGE 45.

Available Optionst -BB Back-to-Back Carrier

-10 Extension Sleeves Longer ThanStandard, Specify Wall Thickness

-60 Valve Plate for Attaching to Upright

-67 Concealed Arm Carrier forWheelchair Lavatory

-75 2" Chrome-Plated Escutcheons-76 4" Chrome-Plated Escutcheons-77 6" Chrome-Plated Escutcheons

APPLICATIONFor use with back-to-back lavatories punched for concealed arms where thin wallconstruction demands uprights that support the fixture completely independent ofthe wall.

SPECIFICATIONJOSAM 17100-BB Series floor-mounted, back-to-back Lavatory Carrier with concealedarms, leveling and securing screws, structural uprights and welded feet.

17100-BB SERIES FLOOR-MOUNT, -BB Back-to-Back

STD. ADJUSTABLE SLEEVE 6-1/2”

VARIABLE – DEPENDS ON FIXTURE.

RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.

STD. ADJUSTABLE SLEEVE 6-1/2”

VARIABLE – DEPENDS ON FIXTURE.

RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.

APPLICATIONFor use with lavatories punched for concealed arms where wall construction willsupport the fixture and carrier assembly.

SPECIFICATIONJOSAM 17120 Series wall-mounted, single Lavatory Carrier with concealed arms,leveling and securing screws and adjustable wall plate.

REUSABLE ALIGNMENT TOOLAVAILABLE. SEE PAGE 45.

17120 SERIES WALL-MOUNT, Concealed Arms

t -BP with Back Platest -MMB with Movable Mounting

Bracketst -10 Extension Sleeves Longer

Than Standard, Specify Wall Thickness

-75 2" Chrome-Plated Escutcheons-76 4" Chrome-Plated Escutcheons-77 6" Chrome-Plated Escutcheons

Available Options

STD. ADJUSTABLE SLEEVE 4”

VARIABLE – DEPENDS ON FIXTURE.

CARR

IERS

Fixture Carriers 08.qxd 4/22/08 6:49 PM Page 46

APPLICATIONFor use with lavatories punched for concealed arms where wall construction will sup-port the fixture and carrier assembly.

SPECIFICATIONJOSAM 17120-MMB Series wall-mounted, single Lavatory Carrier with concealedarms, leveling and securing screws and movable mounting brackets for securing towall plate by others.

APPLICATIONFor use with lavatories punched for concealed arms where wall construction willsupport the fixture and carrier assembly.

SPECIFICATIONJOSAM 17120-10 Series wall-mounted, single Lavatory Carrier with concealed arms,leveling and securing screws and adjustable wall plate.

FIXTURE CARRIERSFIXTURE CARRIERS

47

CARRIERS

APPLICATIONFor use with lavatories punched for concealed arms where wall construction willsupport the fixture and carrier assembly.

SPECIFICATIONJOSAM 17120-BP Series wall-mounted, single Lavatory Carrier with concealed arms,leveling and securing screws, adjustable wall plate and back plate.

17120-10 SERIES WALL-MOUNT with -10 Extension Sleeves Longer than Std.

17120-BP SERIES WALL-MOUNT with -BP Back Plate

17120-MMB SERIES WALL-MOUNT with –MMB Movable Mounting Brackets

STD. ADJUSTABLE SLEEVE 8-1/2”

VARIABLE – DEPENDS ON FIXTURE. 17 LBS

19 LBSSTD. ADJUSTABLE SLEEVE 8-1/2”

VARIABLE – DEPENDS ON FIXTURE.

STD. ADJUSTABLE SLEEVE 6-1/2”

VARIABLE – DEPENDS ON FIXTURE.

PLATE FURNISHEDBY OTHERS

16 LBS

Fixture Carriers 08.qxd 4/22/08 6:49 PM Page 47

FIXTURE CARRIERSFIXTURE CARRIERS

48

APPLICATIONFor use with lavatories punched for concealed arms where wall construction will sup-port the fixture and carrier assembly.

SPECIFICATIONJOSAM 17125 Series wall-mounted, single Lavatory Carrier with concealed arms, lev-eling and securing screws and steel plate for attaching to studs.

APPLICATIONFor use with lavatories designed for heavy-duty exposed arms where thin wall construc-tion demands uprights that support the fixture completely independent of the wall.

SPECIFICATIONJOSAM 17380 Series floor-mounted, single Lavatory Carrier with exposed acid-resist-ing white coated arms, leveling and securing screws, structural uprights, welded feetand chrome-plated trim.

17125 SERIES WALL-MOUNT, Concealed Arms

STD. ADJUSTABLE SLEEVE 4”

VARIABLE – DEPENDS ON FIXTURE. 12 LBS

17380 SERIES FLOOR-MOUNT, Exposed Arms

49 LBS

Available Options

Available Options

t Product Illustration follows.

VARIABLE – DEPENDS ON FIXTURE.

RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.

REUSABLE ALIGNMENT TOOLAVAILABLE. SEE PAGE 45.

WGT 19 LBSWGT 19 LBS

-10 Extension Sleeves Longer Than Standard, Specify Wall Thickness-75 2" Chrome-Plated Escutcheons

t -BB Back-to-Back Carriert -HD Heavy-Duty

-VP Vandal-Proof Trim-10 Hardware for Walls Over 4-1⁄2", Specify Wall Thickness-60 Valve Plate for Attaching to Upright-66 Split Header for Stainless Steel Arms

CARR

IERS

Fixture Carriers 08.qxd 4/22/08 6:49 PM Page 48

FIXTURE CARRIERSFIXTURE CARRIERS

49

CARRIERS

APPLICATIONFor use with back-to-back sinks designed for heavy-duty exposed arms where thinwall construction demands uprights that support the fixture completely independentof the wall.

SPECIFICATIONJOSAM 17380-BB-HD Series floor-mounted, back-to-back, heavy-duty Sink Carrierwith acid-resisting white coated arms, leveling and securing screws, structuraluprights, welded feet and chrome-plated trim.

APPLICATIONFor use with back-to-back lavatories designed for heavy-duty exposed arms where thin wall construction demands uprights that support the fixture completelyindependent of the wall.

SPECIFICATIONJOSAM 17380-BB Series floor-mounted, back-to-back Lavatory Carrier with exposedacid-resisting white coated arms, leveling and securing screws, structural uprights,welded feet and chrome-plated trim.

OPTION N/A-66

APPLICATIONFor use with sinks designed for heavy-duty exposed arms where thin wall construc-tion demands uprights that support the fixture completely independent of the wall.

SPECIFICATIONJOSAM 17380-HD Series floor-mounted, single, heavy-duty Sink Carrier with acid-resisting white coated arms, leveling and securing screws, structural uprights, weldedfeet and chrome-plated trim.

17380-BB SERIES FLOOR-MOUNT, -BB Back-to-Back

17380-HD SERIES FLOOR-MOUNT, -HD Heavy-Duty

17380-BB-HD SERIES FLOOR-MOUNT, -BB Back-to-Back, -HD Heavy-Duty

VARIABLE – DEPENDS ON FIXTURE.

RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.

REUSABLE ALIGNMENT TOOLAVAILABLE. SEE PAGE 45.

REUSABLE ALIGNMENT TOOLAVAILABLE. SEE PAGE 45.

REUSABLE ALIGNMENT TOOLAVAILABLE. SEE PAGE 45.

VARIABLE – DEPENDS ON FIXTURE.

RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.

VARIABLE – DEPENDS ON FIXTURE.

RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.

56 LBS

49 LBS

51 LBS

Fixture Carriers 08.qxd 4/22/08 6:49 PM Page 49

FIXTURE CARRIERSFIXTURE CARRIERS

50

APPLICATIONFor use with lavatories designed for heavy-duty exposed arms where wall constructionwill support the fixture and carrier assembly.

SPECIFICATIONJOSAM 17390 Series wall-mounted, single Lavatory Carrier with exposed acid-resist-ing white coated arms, leveling and securing screws, adjustable wall plate andchrome-plated trim.

APPLICATIONFor use with lavatories designed for heavy-duty exposed arms where wall construc-tion will support the fixture and carrier assembly.

SPECIFICATIONJOSAM 17390-BP Series wall-mounted, single Lavatory Carrier with exposed acid-resisting white coated arms, leveling and securing screws, adjustable wall plate, backplates and chrome-plated trim.

17390 SERIES WALL-MOUNT, Exposed Arms

Available Options

17 LBS

19 LBS

17390-BP SERIES WALL-MOUNT with -BP Back Plates

VARIABLE – DEPENDS ON FIXTURE.

t Product Illustration follows.

VARIABLE – DEPENDS ON FIXTURE.

t -BP with Back Plates-VP Vandal-Proof Trim-10 Hardware for Walls Over 4-1/2", Specify Wall Thickness

CARR

IERS

Fixture Carriers 08.qxd 4/22/08 6:49 PM Page 50

FIXTURE CARRIERSFIXTURE CARRIERS

51

APPLICATIONFor use with lavatories designed for heavy-duty exposed arms where wall construc-tion will support the fixture and carrier assembly.

SPECIFICATIONJOSAM 17405 Series wall-mounted, single Lavatory Carrier with exposed acid-resist-ing white coated arms, leveling and securing screws, mounting rods for securing towall plate by others and chrome-plated trim.

15 LBSVARIABLE – DEPENDS ON FIXTURE.

DIM. BASED ON 1/4" PLATE BY OTHERS.

17405 SERIES WALL-MOUNT, Exposed Arms

Available Options-VP Vandal-Proof Trim-10 Hardware for Walls Over 4", Specify Wall Thickness

CARRIERS

Fixture Carriers 08.qxd 4/22/08 6:49 PM Page 51

FIXTURE CARRIERSFIXTURE CARRIERS

52

REUSABLE ALIGNMENT TOOLAVAILABLE. SEE PAGE 45.

REUSABLE ALIGNMENT TOOLAVAILABLE. SEE PAGE 45.

REUSABLE ALIGNMENT TOOLAVAILABLE. SEE PAGE 45.

34 LBS

34 LBS

32 LBS

APPLICATIONFor use with urinals furnished with hangers that require a carrier for support andwhere thin wall construction demands uprights that support the fixture completelyindependent of the wall.

SPECIFICATIONJOSAM 17550-UR Series floor-mounted single Urinal Carrier with hanger plate,adjustable supporting rods, structural uprights and welded feet.

OPTION N/A-60

APPLICATIONFor use with lavatories furnished with hangers that require a carrier for support andwhere thin wall construction demands uprights that support the fixture completelyindependent of the wall.

SPECIFICATIONJOSAM 17550 Series floor-mounted, single Lavatory Carrier with hanger plate,adjustable supporting rods, structural uprights and welded feet.

Available Options

17550 SERIES FLOOR-MOUNT, Hanger Plate Type

17550-UR SERIES FLOOR-MOUNT, -UR Urinal Carrier

APPLICATIONFor use with back-to-back lavatories. Furnished with hangers that require a carrier forsupport and where thin wall construction demands uprights that support the fixturecompletely independent of the wall.

SPECIFICATIONJOSAM 17550-BB Series floor-mounted, back-to-back Lavatory Carrier with hangerplates, adjustable supporting rods, structural uprights and welded feet.

OPTIONS N/A:-CL, -UR, -WC, -WCBL

VARIABLE – DEPENDS ON FIXTURE EXCEPT WHEN STD. PLATE IS FURNISHED. C=18-1/4".

RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.

17550-BB SERIES FLOOR-MOUNT, -BB Back-to-Back

VARIABLE – DEPENDS ON FIXTURE EXCEPT WHEN STD. PLATE IS FURNISHED. C=18-1/4".

RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.

t Product Illustration follows.

t -BB Back-to-Back Carriert -CL Corner Lavatory Carriert -UR Urinal Carriert -WC Water Cooler Carriert -WCBL Water Cooler Bi-Level Carrier

-10 Hardware for Walls over 4”,Specify Wall Thickness

-60 Valve Plate for Attaching to Upright

VARIABLE – DEPENDS ON FIXTURE EXCEPT WHEN STD. PLATE IS FURNISHED. C=18-1/4".

RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.

CARR

IERS

Fixture Carriers 08.qxd 4/22/08 6:49 PM Page 52

FIXTURE CARRIERSFIXTURE CARRIERS

53

CARRIERS

REUSABLE ALIGNMENT TOOLAVAILABLE. SEE PAGE 45.

UTILIZE A SINGLE ALIGNMENT TOOL TO ALIGN A PAIR OF UPRIGHTS. IF YOU WISHTO BRACE ALL THREE UPRIGHTS SIMULTANEOUSLY, TWO TOOLS ARE NECESSARY.SEE PAGE 45.

36 LBS

29 LBS

APPLICATIONFor use with corner lavatories furnished with hangers that require a carrier for sup-port and where thin wall construction demands uprights that support the fixturecompletely independent of the wall.

SPECIFICATIONJOSAM 17550-CL Series floor-mounted single Lavatory Carrier for supporting cornertype lavatories with hanger plates, adjustable supporting rods, structural uprights andwelded feet.

APPLICATIONFor use with water coolers furnished with hangers that require a carrier for supportand where thin wall construction demands uprights that support the fixture com-pletely independent of the wall.

SPECIFICATIONJOSAM 17550-WC Series floor-mounted single Water Cooler Carrier with hangerplate, adjustable supporting rods, structural uprights and welded feet.

OPTION N/A-60

APPLICATIONFor use with bi-level water coolers furnished with hangers that require a carrier forsupport and where thin wall construction demands uprights that support the fixturecompletely independent of the wall.

SPECIFICATIONJOSAM 17550-WCBL Series floor-mounted bi-level Water Cooler Carrier with hangerplates and adjustable supporting rods, structural uprights and welded feet.

OPTION N/A-60

36 LBS

VARIABLE – DEPENDS ON FIXTURE EXCEPT WHEN STD. PLATE IS FURNISHED. C=18-1/4".

RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.

VARIABLE – DEPENDS ON FIXTURE.

RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.

VARIABLE – DEPENDS ON FIXTURE.

RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.

17550-WC SERIES FLOOR-MOUNT, -WC Water Cooler Carrier

17550-WCBL SERIES FLOOR-MOUNT, -WCBL Water Cooler Bi-Level Carrier

17550-CL SERIES FLOOR-MOUNT, -CL Corner Lavatory Carrier

Fixture Carriers 08.qxd 4/29/08 10:42 AM Page 53

APPLICATIONFor use with lavatories furnished with hangers that require a carrier for support withbearing plate and where thin wall construction demands uprights that support thefixture completely independent of the wall.

SPECIFICATIONJOSAM 17560 Series floor-mounted, single Lavatory Carrier with hanger andbearing plate, adjustable supporting rods, structural uprights, welded feet andchrome-plated trim.

FIXTURE CARRIERSFIXTURE CARRIERS

54

APPLICATIONFor use with back-to-back lavatories furnished with hangers that require a carrier forsupport with bearing plate and where thin wall construction demands uprights thatsupport the fixture completely independent of the wall.

SPECIFICATIONJOSAM 17560-BB Series floor-mounted back-to-back Lavatory Carrier with hangerplates, bearing plates, adjustable supporting rods, structural uprights, welded feet andchrome-plated trim.

OPTIONS N/A:-UR, -WC, -WCBL

Available Options

REUSABLE ALIGNMENT TOOLAVAILABLE. SEE PAGE 45.

REUSABLE ALIGNMENT TOOLAVAILABLE. SEE PAGE 45.

38 LBS

43 LBS

17560 SERIES FLOOR-MOUNT, Bearing Plate Type

17560-BB SERIES FLOOR-MOUNT, -BB Back-to-Back

VARIABLE – DEPENDS ON FIXTURE

RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.

VARIABLE – DEPENDS ON FIXTURE EXCEPT WHEN STD. PLATE IS FURNISHED. C=18-1/2".

RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.

t Product Illustration follows.

t -BB Back-to-Back Carriert -UR Urinal Carriert -WC Water Cooler Carriert -WCBL Water Cooler Bi-Level Carrier

-10 Hardware for Walls over 4”,Specify Wall Thickness

-60 Valve Plate for Attaching to Upright

CARR

IERS

Fixture Carriers 08.qxd 4/22/08 6:49 PM Page 54

FIXTURE CARRIERSFIXTURE CARRIERS

55

CARRIERS

REUSABLE ALIGNMENT TOOLAVAILABLE. SEE PAGE 45.

REUSABLE ALIGNMENT TOOLAVAILABLE. SEE PAGE 45.

UTILIZE A SINGLE ALIGNMENT TOOL TO ALIGN A PAIR OF UPRIGHTS. IF YOU WISHTO BRACE ALL THREE UPRIGHTS SIMULTANEOUSLY, TWO TOOLS ARE NECESSARY.SEE PAGE 45.

38 LBS

61 LBS

APPLICATIONFor use with bi-level water coolers furnished with hangers that require a carrier forsupport with bearing plate and where thin wall construction demands uprights thatsupport the fixture completely independent of the wall.

SPECIFICATIONJOSAM 17560-WCBL Series floor-mounted, double Water Cooler Carrier with hangerplates, bearing plates, adjustable supporting rods, structural uprights, welded feet andchrome-plated trim.

OPTION N/A-60

APPLICATIONFor use with urinals furnished with hangers that require a carrier for support withbearing plate and where thin wall construction demands uprights that support thefixture completely independent of the wall.

SPECIFICATIONJOSAM 17560-UR Series floor-mounted single Urinal Carrier with hanger plate,bearing plate, adjustable supporting rods, structural uprights, welded feet andchrome-plated trim.

OPTION N/A-60

APPLICATIONFor use with water coolers furnished with hangers that require a carrier for supportwith bearing plate and where thin wall construction demands uprights that supportthe fixture completely independent of the wall.

SPECIFICATIONJOSAM 17560-WC Series floor-mounted, single Water Cooler Carrier with hangerplate, bearing plate, adjustable supporting rods, structural uprights, welded feet andchrome-plated trim.

OPTION N/A-60

36 LBS

17560-UR SERIES FLOOR-MOUNT, -UR Urinal Carrier

17560-WCBL SERIES FLOOR-MOUNT, -WCBL Water Cooler Bi-Level Carrier

VARIABLE – DEPENDS ON FIXTURE EXCEPT WHEN STD. PLATE IS FURNISHED. C=18-1/4" AND E DOES NOT APPLY.

RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.

VARIABLE – DEPENDS ON FIXTURE EXCEPT WHEN STD. PLATE IS FURNISHED. C=18-1/4".

RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.

VARIABLE – DEPENDS ON FIXTURE.

RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.

17560-WC SERIES FLOOR-MOUNT, -WC Water Cooler Carrier

Fixture Carriers 08.qxd 4/30/08 9:01 AM Page 55

FIXTURE CARRIERSFIXTURE CARRIERS

56

APPLICATIONFor use with lavatories furnished with hangers that require a carrier for supportwhere wall construction will support the fixture and carrier assembly.

SPECIFICATIONJOSAM 17590 Series wall-mounted, single Lavatory Carrier with hanger plate andadjustable supporting rods.

APPLICATIONFor use with lavatories furnished with hangers that require a carrier for supportwhere wall construction will support the fixture and carrier assembly.

SPECIFICATIONJOSAM 17590-DP Series wall-mounted single Lavatory Carrier with hanger plates andadjustable supporting rods.

Available Options

4 LBS

7 LBS

17590-DP SERIES WALL-MOUNT, -DP Double Plate Carrier

VARIABLE – DEPENDS ON FIXTURE.

STD. PLATE IS 3/16" x 4" x 21-1/2".

VARIABLE – DEPENDS ON FIXTURE.

STD. PLATE IS 3/16" x 4" x 21-1/2".

17590 SERIES WALL-MOUNT, Hanger Plate Type

t Product Illustration follows.

t -DP Double Plate Carriert -UR Urinal Carrier

-10 Hardware for Walls over 7”, Specify Wall ThicknessHardware for Walls over 4" on 17590-DP and 17590-UR-DP,Specify Wall Thickness

CARR

IERS

Fixture Carriers 08.qxd 4/29/08 10:42 AM Page 56

FIXTURE CARRIERSFIXTURE CARRIERS

57

CARRIERS

4 LBS

APPLICATIONMultipurpose carrier for use with urinals furnished with hangers that require a carrierfor support where wall construction will support the fixture and carrier assembly.

SPECIFICATIONJOSAM 17590-UR Series wall-mounted single Urinal Carrier with hanger plate andadjustable supporting rods.

APPLICATIONFor use with urinals furnished with hangers that require a carrier for support wherewall construction will support the fixture and carrier assembly.

SPECIFICATIONJOSAM 17590-UR-DP Series wall-mounted single Urinal Carrier with hanger platesand adjustable supporting rods.

17590-UR-DP SERIES WALL-MOUNT, -UR Urinal Carrier with -DP Double Plates

VARIABLE – DEPENDS ON FIXTURE.

STD. PLATE IS 3/16" x 4" x 21-1/2".

VARIABLE – DEPENDS ON FIXTURE.

STD. PLATE IS 3/16" x 4" x 21-1/2".

17590-UR SERIES WALL-MOUNT, -UR Urinal Carrier

7 LBS

Fixture Carriers 08.qxd 4/22/08 6:49 PM Page 57

FIXTURE CARRIERSFIXTURE CARRIERS

58

APPLICATIONFor use with service sinks designed for heavy-duty exposed arms and hanger platewhere thin wall construction demands uprights that support the fixture completelyindependent of the wall.

SPECIFICATIONJOSAM 17720 Series floor-mounted, single, heavy-duty Sink Carrier with hanger plate,adjustable supporting rods, acid-resisting white coated arms, leveling and securingscrews, structural uprights, welded feet and chrome-plated trim.

APPLICATIONFor use with wash-up sinks designed for heavy-duty exposed arms and hanger platewhere thin wall construction demands uprights that support the fixture completelyindependent of the wall.

SPECIFICATIONJOSAM 17720-66 Series floor-mounted, single, heavy-duty Sink Carrier with hangerplate, adjustable supporting rods and bearing studs, structural uprights, welded feetand chrome-plated trim.

OPTION N/A:-VP

Available Options

59 LBS

34 LBS

17720-66 SERIES FLOOR-MOUNT, with -66 Split Header for Stainless Steel Arms

VARIABLE – DEPENDS ON FIXTURE.

RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.

VARIABLE – DEPENDS ON FIXTURE.

RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.

17720 SERIES FLOOR-MOUNT, Heavy-Duty Type

t Product Illustration follows.

-VP Vandal-Proof Trim-10 Hardware for Walls over 4”, Specify Wall Thickness

t -66 Split Header for Stainless Steel Arms

CARR

IERS

Fixture Carriers 08.qxd 4/29/08 10:42 AM Page 58

FIXTURE CARRIERSFIXTURE CARRIERS

59

CARRIERS

45 LBS

55 LBS

APPLICATIONFor use with 4" back-outlet flushing rim service sinks designed for hanging on heavy-duty studs with support plates and 4" piping connection where thin wall constructiondemands uprights that support the fixture completely independent of the wall.

SPECIFICATIONJOSAM 17730 Series floor-mounted single heavy-duty Sink Carrier with supportplates, adjustable coupling with 4" piping connection, mounting studs, structuraluprights, welded feet and chrome-plated trim.

APPLICATIONFor use with 4" back-outlet flushing rim service sinks designed for hanging on heavy-duty studs with support plates and 4" x 2" waste fitting where thin wall constructiondemands uprights that support the fixture completely independent of the wall.

SPECIFICATIONJOSAM 17735 Series floor-mounted single heavy-duty Sink Carrier with supportplates, adjustable coupling with 4" x 2" waste fitting, mounting studs, structuraluprights, welded feet and chrome-plated trim.

17735 SERIES FLOOR-MOUNT with Fitting

17730 SERIES FLOOR-MOUNT with Adjustable Coupling

Available Options

Available Options

VARIABLE – DEPENDS ON FIXTURE.

RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.

VARIABLE – DEPENDS ON FIXTURE.

ss FOR DIM. LESS THAN 5-3/8”, CUT EXT.

RECOMMEND ALL FEET BE SECURED TO FLOOR WITH 1/2" BOLTS AND ANCHORS BY OTHERS.

ASSY. FOR BLOWOUTFIXTURES WITHTHREE BOLT MOUNT.

-VP Vandal-Proof Trim-11 Cast Iron Adjustable Extension through 12” Length,

Specify 6”, 9”, 12” on Order-60 Valve Plate for Attaching to Upright

-VP Vandal-Proof Trim-10 Hardware for Walls Over 5-3/8", Specify Wall Thickness-45 Threaded High Left-Hand Auxiliary Vent-46 Threaded High Right-Hand Auxiliary Vent

NOTE: Other Fittings Available on Request.Contact your JOSAM Representative.

ASSY. FOR BLOWOUTFIXTURES WITHTHREE BOLT MOUNT.

Fixture Carriers 08.qxd 4/22/08 6:49 PM Page 59

60

JIFFEE-JOINT GASKETSJIFFEE-JOINT GASKETS

19802 2" SW 2.125 2.390 54.0 60.7 • • • •19803 3" SW 3.125 3.390 79.4 86.1 • • • •19804 4" SW 4.125 4.390 104.8 111.5 • • • •19805 5" SW 5.210 5.390 132.3 136.9 • •19806 6" SW 6.210 6.390 157.7 162.3 • •19812 2" XH 2.290 2.470 58.2 62.7 • • • • • •19813 3" XH 3.410 3.590 86.6 91.2 • • • • •19814 4" XH 4.410 4.590 112.0 116.6 • • • • •19815 5" XH 5.410 5.590 137.4 142.0 •19816 6" XH 6.410 6.590 162.8 167.4 •19825 5" SP 5.550 5.70 141.0 144.8 • • •19826 6" SP 6.550 6.70 166.4 170.2 • • • •

SW – Service WeightXH – Extra Heavy SP – Steel Pipe These recommendations apply to pipe that conforms to ANSI, ASTM and other applicable standards.JIFFEE-JOINT Gaskets are designed for use only with JOSAM caulk outlet (-X) products.

Features

JIFFEE-JOINT GASKET Selection1. Determine the outside diameter of pipe to be joined from manufacturer’s reference material or applicable standards.2. Select the proper JIFFEE-JOINT from the tolerance range which includes the pipe diameter.

Example: To join 6" ABS DWV pipe per standard specification ANSI/ASTM D2661 having 6.625 O.D., select type 19826 (6" S.P.) JIFFEE-JOINT (tolerance range 6.550-6.70).Note: Application encompasses any pipe falling within the tolerance range shown. For applications not falling within the charted tolerances,

consult your JOSAM Representative.

JOSAM JIFFEE-JOINTS will join and seal JOSAM inside caulk outlet (-X) drainage products to various types of pipes.

Features• Positive leakproof seal is made immediately. Gasket is

self-centering.

• Joints can be deflected without loss of seal.

• Gasket can be re-adjusted after installation.

• Joints maintain seal under vibration, expansion or contraction.

• Gasket is tough, resistant and unaffected even by extremes in weather or temperature.

• Gaskets are easily installed with commonly used tools even underadverse conditions.

• Gaskets are marked on top for easy identification of type and size.

• Made of Neoprene, conforming to ASTM-C564, JIFFEE-JOINTGaskets present an outstanding record for unlimited service and success in all fields.

There Isn’t A Faster Way To Install JOSAM Products

1. Set drain body to the proper height over pipe.2. Level and support in place.3. After coating gasket and inside of drain with a gasket

lubricant, slip gasket over pipe and press down as far aspossible by hand.

4. Placing a caulking tool in groove at top of gasket, drive the gasket down flush with the pipe top – no further. You have made a perfect joint.

JOSAM 19800 Series elastomeric JIFFEE-JOINT drain outlet Gaskets are made of NEOPRENE which conforms to ASTM-C564 Standard and are for instal-lation of JOSAM inside caulk drainage products on avariety of types of drainage waste and vent pipingwhich conform to ANSI, ASTM and other standards.

JIFFEE-JOINT Gaskets provide a fast, positive method of installing JOSAM drains, cleanouts and other products having inside caulk outlets (-X).These patented gaskets are the result of years of development and proven field use. They save the installer valuable time and assure him of aleakproof joint to virtually any type of pipe, even in inclement weather. As pointed out below, the features offered by this gasket to the specifier,contractor and installer, make good sense – another good reason to specify and install JOSAM plumbing drainage products.

APPLICATION CHART PIPE DIAMETER GASKET-PIPE TABLETOLERANCE RANGE CAST IRON PVC

TYPE NO. DESIGNATION Inches Millimeters SOIL PIPE NO- PLASTIC THIN COPPERFrom Min. To Max. From Min. To Max XH SW HUB ABS PVC WALL STEEL DWV GLASS

JIFF

EE-J

OIN

T G

ASK

ETS

Fixture Carriers 08.qxd 3/27/08 11:46 AM Page 60

61

ROOF DRAINSROOF DRAINSRO

OF

DRA

INS

LEVELEZE® FeaturesLEVELEZE® Roof Drains are just what the name implies – easy to level to the proper elevation. The adjustable integral top is mated to thebody and support ring with a heavy machined thread which permits virtually unlimited top level adjustment to accommodate various insulation thicknesses. The line contact between the threads provides positive circumferential support of the top at any adjusted elevation.This versatile drain readily adapts to changes in finished roof elevation. With LEVELEZE® on the job, installation delays normally encountered, where fixed height extensions are specified, will not be experienced.

WEJLOC® CLAMP RING – GRAVEL STOPEmbodies the exclusive compressionwedge lock principle to secure flashingwith a positive non-puncturing bond to mating flange of collar. The gravelstop prevents roof surface aggregatesfrom being washed into drain while permitting total drainage through "V" notch weirs.

ADJUSTABLE COLLARThe LEVELEZE® machined thread permits raising or lowering of roofflange to meet the insulation thicknessat the required elevation, even afterleader is connected to drain and theroofing is applied.

JIFFEE-SETJOSAM Roof Drains feature JIFFEE-SET connections with MULTI-TITE® service weight (SV) soil pipe gaskets, conforming to ASTMStandard C564 in 2, 3 and 4 inch sizes for labor-saving assemblyto service weight pipe in cast iron, no-hub cast iron, PVC and ABS.Merely lubricate gasket and pipe, push (or insert) until it contactsbuilt-in stop and the joint is complete.

21500-AE Series LEVELEZE®

Large Dome Roof Drain

Conventional Features

SUPPORT RING & GASKETCast iron support ring mates with LEVELEZE® adjustable collar permittingsmooth uninterrupted adjustment toaccommodate various insulation thicknesses. Gasket prevents leakagebetween drain body and support ring.

DOMEPrecision molded polypropylene plastic, low-silhouette dome with124 sq. in. free open drainage flow area, narrow vertical slottedopenings to prevent entrance of debris, and positive locking device.

DRAIN RECEIVERCoated formed steel drain receiver incorporates recessed flange to supportdrain body and wide peripheral flangeto distribute drain load over a broadarea of the deck, also compensating for irregular and off-center deck openings.

BODYHeavy-duty coated cast iron body withwide support flange, large smooth sumpand connection to suit leader piping.Without adjustable collar, the body canbe installed in the deck and connectedto the leader to receive drainage duringconstruction. When roof is ready forinsulation and topping, the collar can beinstalled and set to required elevationfor completion of the installation.

DECK CLAMPHeavy-duty deck clamp secures drainbody to roof deck with the compressionclamp principle forming a permanentbond between drain and roof, preventingany movement of drain and possiblerupture of roofing materials.

WEJLOC® CLAMP RING –GRAVEL STOPEmbodies the exclusive compressionwedge lock principle to secure flashingwith a positive non-puncturing bond tomating flange of body. The gravel stopprevents roof surface aggregates frombeing washed into the drain while permitting total drainage through "V"notch weirs.

DECK CLAMPHeavy-duty deck clamp secures drainbody to roof deck with the compressionclamp principle forming a permanentbond between drain and roof preventingany movement of drain and possiblerupture of roofing materials.

DOMEPrecision molded polypropylene plastic, low-silhouette dome with124 sq. in. free open drainage flow area, narrow vertical slottedopenings to prevent entrance of debris, and positive locking device.

GASKETResilient Neoprene ring-type gasketprovides a watertight joint betweenextension skirt and body flange.

FIXED EXTENSIONOn deck where applied insulation isinvolved, the extension, available invarious heights, is used to bring draintop to roof surface elevation. Theflange is equivalent in diameter to that on the drain body.

DRAIN RECEIVERCoated formed steel drain receiver incorporates recessed flange to supportdrain body and wide peripheral flange todistribute drain load over a broad areaof the deck, also compensating for irregular and off-center deck openings.

BODYHeavy-duty coated cast iron body withwide support flange, large smooth sumpand connection to suit leader piping.

21500 Series LargeDome Roof Drain

Roof Drains_08.qxd 3/28/08 12:14 PM Page 61

62

ROOF DRAINS • Pictorial Selection GuideROOF DRAINS • Pictorial Selection Guide

LARGE SUMP21500

Page 74

21500-AEAdjustable Extension

Page 75

21500-AERAdj. Extension with Threaded Rods

Page 75

21500-16Overflow DrainInternal Waterguard

Page 76

21500-AE-16Overflow Drain with Adjustable Extension

Pages 75, 76

21500-19SS Perforated Gravel Guard

Page 76

LARGE SUMP • Promenade23500

Page 80

23500-AEAdjustable Extension

Page 81

23500-IRMAInverted MembraneSS Perf. Extension

Page 82

23500-IRMA-6IRMA, SS Perf. ExtensionWide Flange

Page 82

23510Parking Deck Drain Extra Heavy-Duty Grate

Page 83

24030Composition DeckMedium Duty

Page 85

LARGE SUMP • Promenade FLO-SEPTOR® DRAINS24050Composition Deck SpecialDuty, 2" Extension

Page 86

24060Composition Deck SpecialDuty, 2" Extension

Page 87

24200Plaza Drain, Slotted Grate,SS Filter

Page 87

EXTRA-DEEP23500-18

Page 81

25500 - Large SumpWater Dam

Page 9225520 - Medium Sump

Water Dam

Page 9325540 - Small Sump

Water Dam

Page 93

LARGE SUMP EXTRA LARGE SUMP21500-IRMAInverted MembraneSS Perf. Extension

Page 77

21500-IRMA-6IRMA, SS Perf. ExtensionWide Flange

Page 77

FLO-SET® 2911212" Outlet

Page 97

28600Calibrated Vanes

Page 96

28600-AECalibrated VanesAdjustable Extension

Page 96

ROO

FD

RAIN

S

Roof Drains_08.qxd 3/28/08 12:14 PM Page 62

63

ROOF DRAINS • Pictorial Selection GuideROOF DRAINS • Pictorial Selection Guide

PARAPET24700Shallow Sump

Page 89

24700-45Shallow Sump,45° Outlet

Page 89

24720Shallow Sump

Page 90

24720-45Shallow Sump,45° Outlet

Page 91

24900Extra Large Angle Grate

Page 91

25000Parapet Scupper Sleeve,Adjustable Wall Collar

Page 91

SMALL SUMP SHALLOW SUMP • SILL TYPE22080Mid-Size Roof Drain

Page 78

PROMENADE 24500Secured Dome

Page 88

24500-45Secured Dome,45° Outlet

Page 88

24500-90Secured Dome,90° Outlet

Page 88

23730Round Grate,Square Frame

Page 84

23740Heavy-Duty Grate

Page 84

MISCELLANEOUS PRODUCTS25010Downspout Nozzle

Page 92

26200Expansion Joint

Page 94

26440Stack Fitting

Page 94

26450Flashing Sleeve,Counterflashing & Caulk Recesses

Page 95

26700Vandal-Proof Vent Cap,Frost-Proof Openings

Page 95

29000Isolation Deck Drain,Large Sump

Page 97

MEDIUM SUMP COMBINATION DRAIN/OVERFLOW22010Mid-Size Roof Drain

Page 78

PROMENADE 22100 - Small Sump

Page 7922200 - Medium Sump

Page 7922500 - Large Sump

Page 79

23710Round Grate,Square Frame

Page 83

24020Composition Deck

Page 85

24040Composition Deck2" Extension

Page 86

ROO

FD

RAIN

S

Roof Drains_08.qxd 3/28/08 12:14 PM Page 63

64

ROOF DRAINSROOF DRAINSRO

OF

DRA

INS

Unless optional materials are specified, standard material shown in Specification will be provided. Last digit indicates outlet size.

Drain Receivers

How To Order Roof Drains

21504 -Z -22 -VP

Outlet SizeOutlet Type, No-Hub Spigot OutletOptional Material, Cast Iron DomeOption, Secured Dome, Vandal-Proof Screws

EXAMPLE: Series No. 21500 Type No. 21504

TABLE OF DIMENSIONSSERIES NO. A B C D

21500 24 15-1/2 14-9/16 21/6422010 20 12-1/4 11-1/2 21/6422080 16 9-1/2 7-1/2 47/64

DRAINSERIES

APPLICABLE DRAIN RECEIVER

OUTLET SIZE

2 3 4 5 6 8 10

21500 2150021500-CR

2150021500-CR

2150021500-CR

2150021500-CR

2150021500-CR

2150021500-CR

2150021500-CR

22010 22010 22010 22010 22010 2201022080 22080 22080 2208023710 22010 22010 22010 22010 2201023730 22080 22080 2208023740 22080 22080 22080

25500 2150021500-CR

2150021500-CR

2150021500-CR

2150021500-CR

2150021500-CR

2150021500-CR

25520 22010 22010 22010 22010 2201025540 22080 22080 22080

28600 2150021500-CR

2150021500-CR

2150021500-CR

2150021500-CR

2150021500-CR

2150021500-CR

Roof Drains_08.qxd 3/28/08 12:14 PM Page 64

65

ROOF DRAINSROOF DRAINS

(-2) OPTION, DRAIN RECEIVERThe drain receiver is recommended for use in all roof drain installations regard-less of deck construction and is of particular importance when used in conjunc-tion with drains installed in decks where support is on insulation. The drainreceiver is produced in heavy gauge steel, coated for protection, and embodiesa recessed flange to carry the drain, and a wide flange to support the assemblyon the roof. The drain receiver distributes the weight of the roof drain evenlyover the deck and compensates for irregular and misaligned deck openings.

(-1) OPTION, DECK CLAMPThe deck clamp is the most dependable means by which the roof drain can besecured to the roof deck to insure a permanent bond that will prevent damage of flashing and membrane materials caused by movement and vibration. It is secured tothe underside of the drain body with heavy-duty threaded rods, which provide adjust-ment to accommodate various slab or deck thicknesses, and is drawn tightly in placeagainst the underside of the deck to form a positive union.

(-66) NO-HUB SIDE OUTLETThis option converts JOSAM bottom outlet inside caulk drains to no-hub side outletdrains using a 90º no-hub quarter bend and a JIFFEE-JOINT Gasket.

(-10) OPTION, FIXED EXTENSION COLLAR USED WITH LEVELEZE® DRAINSFor roof or deck construction where base slab to surface height is greater than can be accommodated with the standard LEVELEZE® collar, the (-10) Fixed ExtensionCollar “A” is used along with the LEVELEZE® assembly. These collars can be used in multiples where extension requirements dictate. The Fixed Extension Collar can be cast in increments of 1, 2, 3 and 4 inches. Shorter or longer dimensions are available by cutting or stacking extensions

(-VP) OPTION, VANDAL-PROOF SECURED DOMEWhere vandalism or mischievous activity is anticipated, it is advisable to specifyvandal-proof domes on roof drains. All JOSAM precision-molded plastic largedomes incorporate bayonet locking devices as standard equipment; however, whenspecified vandal-proof, they are further secured with screws to insure permanenceof assembly. Other types of domes can also be vandal-proofed when specified.

(-3C) OPTION, DRAIN RECEIVER & DRAIN RECEIVER CLIPSIncludes (-2) Optional Drain Receiver and clips, to secure the roof drain bodydirectly to the receiver. Simply position the drain outlet face up, position drainreceiver over the drain body and attach the four receiver clips with the hardwareprovided. Invert body and install the assembly into the deck opening. If necessary,secure assembly to the metal deck with self-tapping screws (by others).

OptionsThe variations shown below illustrate and explain various roof drain components. These variations must be specifiedand installed when the type of roof construction dictates their use. See specific series for available options.

PIPE SIZE A B

2 2-1/2 4-1/23 2-13/16 54 3-1/2 5-1/25 4-5/16 6-1/26 4-13/16 7

ROO

FD

RAIN

S

Roof Drains_08.qxd 3/28/08 12:14 PM Page 65

66

ROOF DRAINSROOF DRAINSRO

OF

DRA

INS

Conventional Roof Drainage SystemsSIZING WORKSHEETThe number of roof drains for a given project can be determined bythe ratio method which indicates that roof drains be installed at theminimum of one roof drain for each 10,000 sq. ft. of roof area. Therainfall for a given locality is found in Figure 4, or in Figure 5 if thelocality is not listed. Figure 7 converts the rainfall to G.P.M., andFigure 8 provides the system sizing data. The sizing worksheet shownin Figure 1 offers a quick sizing procedure to be followed by the engineer, and it also serves as a file record on the project. The conventional roof drainage requirements for a project have beendetermined on the example worksheet (Figure 1).

Note: A supply of worksheets can be obtained from your local JOSAMRepresentative.

PLUMBING CODE AUTHORITIESEven though rainfall data in Figures 4 and 5 are composites of officialrecordings at the time of this publication, it is recommended thatlocal code authorities be consulted for rainfall amounts they specifyfor design purposes. In those instances where local specified rainfallis different from that in Figures 4 and 5, use the local specifications incompleting the worksheet.

LAYOUT OF DRAINS AND PIPINGUsing the conventional roof drainage requirements as determined in the worksheet (Figure 1), a suggested placement of roof drains isshown in Figure 2, and a typical drainage piping arrangement isshown in Figure 3. With reference to Figure 2, the drains should not be located more than 50 ft. from the roof perimeter nor morethan 100 ft. apart. With reference to Figure 3, the horizontal piping is sized based on a slope of 1/4 inch per ft.

Note: Cleanouts should be provided in both the vertical and horizontal drainage piping systems. Local plumbing codes should be consulted relative to acceptable design and installation of thedrainage piping system and its components.

FIGURE 3

FIGURE 1

TYPICAL PIPING ARRANGEMENT ROOF PLAN

FIGURE 2

Roof Drains_08.qxd 3/28/08 12:14 PM Page 66

67

ROOF DRAINSROOF DRAINSRO

OF

DRA

INS

Conventional Roof Drainage SystemsPURPOSEThe roof drainage system is designed to receive rainwater as it falls on the roof and convey it to the street, sewer facilities or other means available for itsdisposal. This system should be sized to handle the maximum rainfall used as design criteria for a project. The following information covers the basicrequirements for the sizing of conventional roof drainage systems and the placement of their components.

RAINFALL DATAThe rainfall that can be expected in a given locality can be obtained from the local code authorities or the nearest rainfall recording station. A study of themaximum rate of rainfall in inches per hour that has been recorded or estimated in U.S. Weather Bureau technical papers No. 2, No. 25, and No. 40 hasenabled us to develop a composite average of maximum rainfall data for design purposes in various localities as shown in Figure 4. For localities that havenot been listed, the approximate maximum rainfall data can be determined from the map shown in Figure 5. It is recommended that the local code authorities be consulted regarding the specific rainfall amount that they may anticipate for design purposes.

OVERFLOW RELIEFThe perimeter edge of a roof structure is generally elevated by parapets, cants or other means. A blockage in the drainage piping could cause a waterbuildup which could overload the roof structure. To prevent this occurrence, it is recommended that overflow relief measures such as scupper or parapetdrains be specified at the ratio of at least one for each 20,000 sq. ft. of roof area. The invert elevation of the scupper should not be more than a safe waterdepth as determined in conjunction with the architect and structural engineer, not more than 5 inches above roof level on flat roofs and 6 inches above lowpoint on sloped roofs.

PLACEMENTThe placement of roof drains is influenced by roof structure support columns, expansion joints, dividers and other projections. Careful consideration of theseelements during the placement-planning phase is essential to provide adequate drainage for each area. Figure 2 shows how the roof drains can be placedon a dimensional basis with a maximum limit from the edge of the roof and between drains.

QUANTITYTo minimize water ponding and insure complete drainage, two roof drains should be installed for total roof areas of 10,000 sq. ft. or less. For larger roofareas, roof drains should be installed at the minimum of one drain for each 10,000 sq. ft. of roof area.

Roofs are of various shapes and dimensions, with sections which may be more or less than the 10,000 sq. ft. recommendation for each drain. Therefore,sometimes it will be necessary to depart from this recommendation as required for proper placement and uniform distribution of roof drains.

State Rainfall

& in inches

City per hour

ALABAMAAnniston 3.6Birmingham 3.6Mobile 4.2Montgomery 3.8ALASKAAnchorage 1.0Fairbanks 1.2Juneau 1.0ARIZONAPhoenix 2.5Tucson 3.0ARKANSASBentonville 3.8Fort Smith 3.9Little Rock 3.7CALIFORNIABakersfield 1.5Eureka 1.6Fresno 1.5Los Angeles 2.0Sacramento 1.4San Diego 1.5San Francisco 1.6San Jose 1.6COLORADODenver 2.5Durango 1.7Grand Junction 1.6Pueblo 2.6CONNECTICUTHartford 3.0New Haven 3.0DELAWAREWilmington 3.5

IOWABurlington 3.3Davenport 3.2Des Moines 3.3Dubuque 3.1Sioux City 3.3KANSASConcordia 3.7Dodge City 3.6Topeka 3.7Wichita 3.7KENTUCKYLexington 2.8Louisville 2.9LOUISIANALake Charles 4.4New Orleans 4.5Shreveport 4.0MAINEPortland 2.3MARYLANDBaltimore 3.4MASSACHUSETTSBoston 2.6Nantucket 3.0MICHIGANAlpena 2.2Detroit 3.0Escanaba 2.3Grand Rapids 2.6Marquette 2.2Port Huron 2.4Saginaw 2.4Sault St. Marie 2.0

MINNESOTADuluth 2.6Minneapolis 3.0St. Paul 3.0MISSISSIPPIJackson 3.8Meridan 3.8Vicksburg 3.7MISSOURIColumbia 3.6Hannibal 3.4Kansas City 3.7St. Joseph 3.6St. Louis 3.4Springfield 3.7MONTANABillings 2.0Havre 1.8Helena 1.5Missoula 1.3NEBRASKALincoln 3.6North Platte 3.3Omaha 3.5NEVADAReno 1.2NEW HAMPSHIREConcord 2.4NEW JERSEYAtlantic City 3.5Newark 3.0Trenton 3.2NEW MEXICOAlbuquerque 2.1Roswell 2.6Santa Fe 2.2

NEW YORKAlbany 2.5Binghamton 2.5Buffalo 2.4New York 3.2Rochester 2.4Syracuse 2.3NORTH CAROLINAAsheville 3.2Charlotte 3.4Greensboro 3.4Raleigh 3.7Wilmington 4.0NORTH DAKOTABismark 2.8Fargo 2.8OHIOCincinnati 2.7Cleveland 3.0Columbus 2.7Dayton 2.6Sandusky 3.0Toledo 3.0Youngstown 2.6OKLAHOMAOklahoma City 3.9Tulsa 3.9OREGONMedford 1.4Pendleton 1.0Portland 1.4PENNSYLVANIAAllentown 3.0Erie 3.0Harrisburg 2.9Philadelphia 3.3

Pittsburgh 2.7Reading 3.0Scranton 2.6PUERTO RICOSan Juan 4.0RHODE ISLANDBlock Island 3.0Providence 3.0SOUTH CAROLINACharleston 4.1Columbia 3.6Greenville 3.4SOUTH DAKOTAPierre 2.9Rapid City 2.7Sioux Falls 3.3TENNESSEEChattanooga 3.3Knoxville 3.2Memphis 3.6Nashville 3.1TEXASAbilene 3.5Amarillo 3.4Austin 4.0Brownsville 4.5Corpus Christi 4.5Dallas 4.0Del Rio 4.5El Paso 2.4Fort Worth 4.0Galveston 4.6Houston 4.5Port Arthur 4.5San Antonio 4.0Wichita Falls 3.8

UTAHSalt Lake City 1.3VERMONTBurlington 2.0VIRGINIALynchburg 3.4Norfolk 3.8Richmond 3.6Roanoke 3.3WASHINGTONPort Angeles 1.0Seattle 1.0Spokane 1.0Tacoma 1.1Walla Walla 1.0Yakima 1.0WEST VIRGINIACharleston 2.8Huntington 2.8Parkersburg 2.6WISCONSINGreen Bay 2.6La Crosse 2.9Madison 3.0Milwaukee 2.7WYOMINGCasper 2.1Cheyenne 2.5Sheridan 2.1Yellowstone Park 1.5

State Rainfall

& in inches

City per hour

State Rainfall

& in inches

City per hour

State Rainfall

& in inches

City per hour

State Rainfall

& in inches

City per hour

State Rainfall

& in inches

City per hour

State Rainfall

& in inches

City per hourDISTRICT OF COLUMBIAWashington 3.4FLORIDAApalachicola 4.3Fort Meyers 4.3Jacksonville 4.0Key West 4.5Miami 4.6Pensacola 4.3Tampa 4.2GEORGIAAtlanta 3.5Augusta 3.6Columbus 3.7Macon 3.7Savannah 4.0Thomasville 4.0HAWAIIHilo 3.0Honolulu 3.2IDAHOBoise 1.1Lewiston 1.1Pocatello 1.3ILLINOISCairo 3.4Chicago 3.0Peoria 3.1Springfield 3.3INDIANAEvansville 3.0Fort Wayne 2.6Indianapolis 2.8South Bend 2.8Terre Haute 2.9

FIGURE 4

Roof Drains_08.qxd 3/28/08 12:14 PM Page 67

68

ROOF DRAINSROOF DRAINSRO

OF

DRA

INS

Conventional Roof Drainage Systems

RAINFALL MAPThe maximum rate of rainfall for a number of localities is shown in Figure 4. For localities that are not listed, see the rainfall map (Figure 5).The maximum rainfall curves shown on this map have been compiled on the basis of a composite average of recorded rainfall data. The rainfall curves in Figure 5 represent maximum rainfall. These can be expressed as 100-year storm curves. To arrive at the rainfall for 50-, 25-and 10-year return period storms, a constant .3 inch reduction factor for each storm period is employed for each curve. (Use Figure 6) If the location desired falls between two curves, an estimate should be made as to how far away the location is and then adjust the rainfallaccordingly. EXAMPLE: Salt Lake City is approximately 1/2 of the way between the curves of 1.0 and 1.5, therefore, the estimate of 1.3would be used.

FIGURE 5

100 Yr. 50 Yr. 25 Yr. 10 Yr.Max. Max. Max. Max.Storm Storm Storm Storm

1.0 1.0 1.0 1.0

1.5 1.2 1.0 1.0

2.0 1.7 1.4 1.1

2.5 2.2 1.9 1.6

3.0 2.7 2.4 2.1

3.5 3.2 2.9 2.6

4.0 3.7 3.4 3.1

4.5 4.2 3.9 3.6

FIGURE 6

Note: 1 inch rainfall is considered minimum for design purposes. The data inFigure 6 is adjusted accordingly.

Roof Drains_08.qxd 3/28/08 12:14 PM Page 68

69

ROOF DRAINSROOF DRAINSConventional Roof Drainage Systems

6.0 3.740 .0624

5.9 3.678 .0614

5.8 3.615 .0603

5.7 3.553 .0593

5.6 3.491 .0582

5.5 3.428 .0572

5.4 3.366 .0562

5.3 3.304 .0551

5.2 3.241 .0541

5.1 3.179 .0530

5.0 3.117 .0520

4.9 3.054 .0510

4.8 2.992 .0499

4.7 2.930 .0489

4.6 2.867 .0478

4.5 2.805 .0468

4.4 2.743 .0458

RAINFALL CONVERSION DATARainfall is expressed in inches of water per hour. For sizing purposes, it is necessary to convert "inches per hour" to "gallons per minute." The data in Figure 7 represents the conversion of rainfall in "inches per hour" to "gallons per hour per sq. ft." and "gallons per minute per sq. ft." For example, a 3 inch per hour rainfall will build up to a 3 inch depth on a flat roof in one hour, at the rate of 1.87 gallons per hour/sq. ft. or .0312gallons per minute/sq. ft. (See Figure 7). Using a 10,000 sq. ft. roof area, the 3 inch rainfall will produce 18,700 gallons in one hour at the rate of 312 gallons per minute. See the following.

SYSTEM SIZING DATARainfall, when expressed in G.P.M. can be appliedto the table in Figure 8 to determine the sizes ofthe various components of the conventional roofdrainage system, including roof drains, verticalleaders and horizontal drainage piping. UsingFigure 8, the 312 G.P.M. rate of rainfall wouldrequire a 5 inch roof drain and leader as well as a 6 inch horizontal drainage line if a slope of 1/4inch per foot were selected.

2 30 - - -2-1/2 54 - - -

3 92 34 48 694 192 78 110 1575 360 139 197 2786 563 223 315 4468 1208 479 679 95810 - 863 1217 172512 - 1388 1958 277515 - 2479 3500 4958

4.3 2.680 .0447

4.2 2.618 .0437

4.1 2.556 .0426

4.0 2.493 .0416

3.9 2.431 .0406

3.8 2.369 .0395

3.7 2.306 .0385

3.6 2.244 .0374

3.5 2.182 .0364

3.4 2.119 .0354

3.3 2.057 .0343

3.2 1.995 .0332

3.1 1.932 .0322

3.0 1.870 .0312

2.9 1.808 .0302

2.8 1.745 .0291

2.7 1.683 .0281

2.6 1.621 .0270

2.5 1.558 .0260

2.4 1.496 .0250

2.3 1.434 .0239

2.2 1.371 .0229

2.1 1.309 .0218

2.0 1.247 .0208

1.9 1.184 .0198

1.8 1.122 .0187

1.7 1.060 .0177

1.6 .997 .0166

1.5 .935 .0156

1.4 .873 .0146

1.3 .810 .0135

1.2 .748 .0125

1.1 .686 .0114

1.0 .623 .0104

RainfallIn G.P.H. G.P.M.

Inches Per 1 Per 1Per Hr. Sq. Ft. Sq. Ft.

RainfallIn G.P.H. G.P.M.

Inches Per 1 Per 1Per Hr. Sq. Ft. Sq. Ft.

RainfallIn G.P.H. G.P.M.

Inches Per 1 Per 1Per Hr. Sq. Ft. Sq. Ft.

Roof Drain Horiz. Storm Drainage Piping G.P.M.Pipe and Vertical

Diameter Leaders Slope – Inches Per Ft.(Inches) (G.P.M.) 1/8 1/4 1/2

FLOW CAPACITY FOR STORM DRAINAGE SYSTEMS IN GALLONS PER MINUTE

Gallons Per Hour10,000 x 1.87 = 18,700 G.P.H.

Gallons Per Minute10,000 x .0312 = 312 G.P.M.

FIGURE 7

FIGURE 8

EXAMPLE:

ROO

FD

RAIN

S

Roof Drains_08.qxd 3/28/08 12:14 PM Page 69

FLO-SET® Control Flow FeaturesThe JOSAM FLO-SET® Roof Drain has four straight weirs incorporated in the vane collar assembly. The vane collar is 6” high to satisfy water storage upto a 6” maximum on a sloped roof. The weirs in the vane collar assembly are adjustable to permit a minimum peak flow of 15 G.P.M. to a maximumpeak flow of 420 G.P.M. at the 6” elevation.

28600 FLO-SET® ROOF DRAIN

70

ROOF DRAINSROOF DRAINSRO

OF

DRA

INS

The correct weir opening to fill any requirement is accomplished by means of a calibrated setting. From information received concerning the location ofthe project, the size and quantity of drains, maximum storage depth and peak flow rate, the proper adjustment is pre-set by JOSAM before shipping.

BENEFITS OF CONTROL FLOW DRAINAGE

REDUCED DRAINAGE COSTSControlled Flow can account for installation savings from reductionin the size of roof drains, leaders and horizontal drainage piping.

REDUCED STORM DAMAGEDelaying rate of water flow fromroof lessens occurrence of storm system overflows, especially in areas utilizing combined sewers.

SLOTTED, SECUREDCAST IRON DOME

ADJUSTABLE VANE COLLAR

WEJLOC® CLAMP COLLARWITH STATIONARY VANESpre-set and Vandal-Proofed at the factory.

DRAIN BODY

STATIONARY VANES AND ADJUSTABLE COLLARThis combined weir arrangement permits water storage up to 6” maximum. The straight weir is theonly weir able to produce the same basic type of flowpattern. It is the only type of weir, therefore, that isideal or practical for adjustable purposes.

ADJUSTABLE VANE COLLARThe adjustable vane collar is marked with 18 differentweir openings thereby permitting controlled dischargeflow rates to a maximum of 420 G.P.M. The correctweir opening can be provided to fulfill the exact needsof any given controlled flow application involving flator sloped roofs.

TOP VIEW OF COMPLETE ASSEMBLYwith Vandal-Proofed weirs and secured cast irondome.

Roof Drains_08.qxd 3/28/08 12:14 PM Page 70

Replacement Parts

71

ROOF DRAINSROOF DRAINS

Josam introduced the first non-puncturing clamping device for roof drains in the 1920’s. By casting lugs into the body and flat tabs onto the clampring, the membrane could be clamped between the drain body and clamp ring using the 410 Clamp Posts. The original design can be identified inthe field by the use of these clamp posts to secure the body to the clamp ring. The 410 and 4110 Series replacement parts below are for use withthese original drains. Please use these drawings to check dimensions carefully as replacement parts are not returnable.

410 CLAMP POST PACK 4110 C.I. DOME Use with 410 Clamp Ring

410 C.I. DOME Use with 410 Clamp Ring 21500 DOME

410 C.I. CLAMP RING Use with 410/4110 Domes 21500 C.I. CLAMP RING

Part No. Description010245 Clamp Post Pack (Four to a Pack)

Type Part No.414 N.S. 010320T

Type Part No. A C D Use with Domes414 010350 13-3/4 1-7/16 10-7/8 414 N.S., 4114 O.S.415 010520 15-1/4 1-9/16 11-11/16 4116 O.S.416 010660 15-3/4 1-1/2 12-3/4 4116 O.S.418 010800T 17-3/16 1-3/8 14-11/16 4118

Part No. Description029273 Polypropylene Dome029279F Cast Iron Dome029275T Aluminum Dome

Type Part No. A B4114 O.S. 029240 12-1/4 5-3/84116 029350 14-1/6 5-3/84118 029420T 16-3/8 6-13/32

Part No. Description029269F 21504 Cast Iron Clamp Ring029278T 21500 Clamp Ring Hardware Pack

ROO

FD

RAIN

S

Roof Drains_08.qxd 4/22/08 6:24 PM Page 71

72

ROOF DRAINSROOF DRAINSRO

OF

DRA

INS

Typical Installations

GYPSUM ROOF DECK SYSTEM TYPICAL ROOF CONSTRUCTION

TYPICAL INSULATED ROOF MEMBRANE SYSTEM PRECAST CONCRETE DECK STEEL ROOF DECK

WOOD JOIST STRUCTURAL STEELROOF SYSTEM JOIST ROOF SYSTEM

PRECAST SOLID CONCRETE PRECAST HOLLOW CELLROOF DECK SYSTEM ROOF DECK SYSTEM

21500-AE Series 21500 Series with 26200 Series EXPANSION JOINT

21500-IRMA Series 21500-66 Series

22010 Series 22080 Series

Roof Drains_08.qxd 3/28/08 12:14 PM Page 72

73

ROOF DRAINSROOF DRAINSRO

OF

DRA

INS

Typical Installations

STEEL-SUPPORTED BUILT-UP ROOF DECK SYSTEM TYPICAL INSULATED ROOF MEMBRANE SYSTEM

CONCRETE DECK WITH ASPHALT PARKING SURFACE PRECAST HOLLOW CELL ROOF DECK

ALL-LEVEL DRAINAGE PROMENADE DECKSTEEL DECK CONCRETE SYSTEMWITH COMPOSITION MEMBRANE SURFACE

23500-AE Series Promenade Roof Drain 23500-IRMA Series

23510 Series Promenade Roof Drain 23730 Series Promenade Roof Drain

24020 Series SUPER-FLO® Composition Deck Drain 24200 Series ALL-LEVEL Drain

Roof Drains_08.qxd 3/28/08 12:14 PM Page 73

APPLICATIONUsed on roofs of any size, typically concrete decking, large slotted dome ensuresmaximum free area for quick drainage of rainwater and protects the drain sumpand connected piping from debris. WEJLOC® compression-flashing clamp holds themembrane or flashing securely to the drain body. Extra wide flange provides posi-tive support and large bonding surface for liquid applied membranes.

SPECIFICATIONJOSAM 21500-6 Series coated cast iron Roof Drain, large polypropylene lockingdome. WEJLOC® non-puncturing clamp ring with integral gravel stop, large sumpwith extra-wide roof flange and bottom outlet inside caulk connection.

OPTIONS N/A:-AER, -CR, -1C, -2, -3, -3C, -4

APPLICATIONUsed on roofs of any size, for any type of construction. Large slotted dome providesmaximum free area for quick drainage of rainwater and protects the drain sump andconnected piping from debris. WEJLOC® compression flashing clamp holds the mem-brane or flashing securely to the drain body.

SPECIFICATIONJOSAM 21500 Series coated cast iron Roof Drain, large polypropylene locking dome,WEJLOC® non-puncturing clamp ring with integral gravel stop, large sump with wideroof flange and bottom outlet.

Available Optionst -AE LEVELEZE® Adjustable Ext.t -AER Adjustable Extension Using

Threaded Rodst -IRMA Perforated Stainless

Steel Extension-CR Clamping Drain Receiver-1 Deck Clamp Assembly-1C Drain Receiver Clips (Min.

Deck Opening 16.5" Dia.)-2 Drain Receiver-3 Deck Clamp Assembly and

Drain Receiver-3C Drain Receiver and

Drain Receiver Clips-4 Secondary Flashing Clamp

(use with -AE only)t -6 Extra Wide Flange Drain

Body, 2"- 6"-X only-10 Fixed Ext. Collar, C.I., (Specify

Hgt.) 4"Std.-10-20 Fixed Ext. Collar, Galv.,

(Specify Hgt.) 4"Std.

t -16 * Internal Waterguard 2"- 6" Outlets Only

-17 * 2" High Solid Clamping Collar

t -19 Clamp Collar w/Perforated SS Gravel Guard

-20 Galv. Cast Iron Parts-21 Galv. Cast Iron Dome Only-22 Cast Iron Dome-23 Rough Bronze Dome-26 Aluminum Dome-33 Stainless Mesh

Screen-Covered Dome-VP Vandal-Proof Dome

OUTLETS:-66 No-Hub Side Outlet, 2"-6"-T Threaded Outlet-X Inside Caulk Outlet-Y Hub Outlet w/Gasket, 2"-4"-Z No-Hub Spigot Outlet

*-16 and -17 cannot be furnished together.

ROOF DRAINSROOF DRAINS

74

ROO

FD

RAIN

S

21500 SERIES LARGE SUMP

21500-6 SERIES LARGE SUMP with -6 Extra Wide Flange Drain Body

CONFORMS WITH ASTM-C564.• THIS DIM. IS 5-3/4" FOR 21508-T.

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.21502 2 36 21506 6 4021503 3 37 21508 8 4221504 4 38 21509-Z 10† 4321505 5 39 †10” AVAILABLE IN NO-HUB ONLY.

FOR OUTLET TYPE SPECIFY -XTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.21502-6 2 77 21505-6 5 8021503-6 3 78 21506-6 6 8121504-6 4 79

t Product Illustration follows.

Roof Drains_08.qxd 4/30/08 10:53 AM Page 74

APPLICATIONUsed on roofs of any size, for any type of construction. Large slotted dome providesmaximum free area for quick drainage of rainwater and protects the drain sump andconnected piping from debris. WEJLOC® compression flashing clamp holds the mem-brane or flashing securely to the drain body. LEVELEZE® adjustable extensionaccommodates insulation of variable thickness.

SPECIFICATIONJOSAM 21500-AE Series coated cast iron LEVELEZE® Roof Drain, large polypropylenelocking dome, WEJLOC® non-puncturing clamp ring with integral gravel stop, boltedsupport ring, adjustable top with wide roof flange, large sump with anchor flangeand bottom outlet.

ROOF DRAINSROOF DRAINS

75

21500-AE SERIES LARGE SUMP with -AE Threaded Adjustable Extension

21500-AER SERIES LARGE SUMP with -AER Adjustable Ext. Using Threaded Rods

s WITH CLAMP RING 2-1/4" MIN. 4-1/4" MAX.CONFORMS WITH ASTM-C564.

• THIS DIM. IS 5-3/4" FOR 21508-AE-T.

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.21502-AE 2 60 21506-AE 6 5821503-AE 3 59 21508-AE 8 6121504-AE 4 59 21509-AE-Z 10† 6221505-AE 5 58 †10” AVAILABLE IN NO-HUB ONLY.

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.21502-AER 2 44 21506-AER 6 4821503-AER 3 45 21508-AER 8 5021504-AER 4 46 21509-AER-Z 10† 5121505-AER 5 47 †10” AVAILABLE IN NO-HUB ONLY.

APPLICATIONUsed on roofs of any size, for any type of construction. Large slotted dome providesmaximum free area for quick drainage of rainwater and protects the drain sump andconnected piping from debris. WEJLOC® compression flashing clamp holds the mem-brane or flashing securely to the drain body. Threaded rods attached to drain bodyand receiver permit the raising and lowering of roof drain body to meet the insula-tion thickness at the required elevation.

SPECIFICATIONJOSAM 21500-AER Series coated cast iron roof drain, large polypropylene lockingdome, WEJLOC® non-puncturing clamp ring, large sump with adjustable extensionrods, drain receiver and bottom outlet.

OPTIONS N/A:-AE, -1, -1C, -2, -3, -3C, -4, -10, -10-20

ROO

FD

RAIN

S

Roof Drains_08.qxd 3/28/08 12:14 PM Page 75

APPLICATIONUsed on roofs of any size, for any type of construction where constant flooding isrequired at a predetermined water depth. It may also be used on conventional roofsas a safety overflow, which receives water only when the build-up is greater than theheight of the standpipe. Large slotted dome provides maximum free area for quickdrainage of rainwater and protects the drain sump and connected piping from debris.WEJLOC® compression-flashing clamp holds the membrane or flashing securely to thedrain body.

SPECIFICATIONJOSAM 21500-16 Series coated cast iron Roof Drain, internal waterguard type, andlarge polypropylene locking dome. WEJLOC® non-puncturing clamp ring with integralgravel stop, secured plastic internal waterguard for 3" water depth and large sumpwith wide roof flange and bottom outlet.

OPTIONS N/A:-4, -17

APPLICATIONUsed on flat roofs where gravel ballast is employed to anchor the membrane. Largeslotted dome provides maximum free area for quick drainage of rainwater and pro-tects the drain sump and connected piping from debris. WEJLOC® compression flash-ing clamp holds the membrane or flashing securely to the drain body. Perforatedstainless steel gravel guard and restrains gravel ballast from dome and drain sump.

SPECIFICATIONJOSAM 21500-19 Series coated cast iron Roof Drain, large polypropylene lockingdome, WEJLOC® non-puncturing clamp ring with integral gravel stop and stainlessperforated gravel guard and large sump with wide roof flange and bottom outlet.

OPTION N/A:-4

ROOF DRAINSROOF DRAINS

76

ROO

FD

RAIN

S

21500-16 SERIES LARGE SUMP with -16 Internal Waterguard

21500-19 SERIES LARGE SUMP with -19 Perforated Stainless Steel Gravelguard

CONFORMS WITH ASTM-C564.

CONFORMS WITH ASTM-C564.• THIS DIM IS 5-3/4” FOR 21508-19-T.

** “K” DIM. SPECIFY ON ORDER, 4” MAX.

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.21502-16 2 41 21505-16 5 4421503-16 3 42 21506-16 6 4521504-16 4 43

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.21502-19 2 36 21506-19 6 4021503-19 3 37 21508-19 8 4221504-19 4 38 21509-19-Z 10† 4321505-19 5 39 †10” AVAILABLE IN NO-HUB ONLY.

Roof Drains_08.qxd 3/28/08 12:14 PM Page 76

APPLICATIONUsed on roof systems where the “Insulated Membrane Assembly,” also known as,“Inverted Membrane Assembly” is specified. Insulation is installed on top of thewaterproof membrane and gravel ballast is applied over the insulation. Drain is fur-nished with a perforated stainless steel extension, made to the specified height of the insulation combined with the depth of the ballast. Large slotted dome providesmaximum free area for quick drainage of rainwater and protects the drain sump andconnected piping from debris. WEJLOC® compression flashing clamp holds the mem-brane or flashing securely to the drain body.

SPECIFICATIONJOSAM 21500-IRMA Series coated cast iron Roof Drain, large polypropylene lockingdome, dome support ring, perforated stainless steel extension filter, WEJLOC® non-puncturing clamp ring and large sump with wide roof flange and bottom outlet.

OPTION N/A:-4

APPLICATIONUsed on roof systems where the “Insulated Membrane Assembly,” also known as,“Inverted Membrane Assembly” is specified. Insulation is installed on top of thewaterproof membrane and gravel ballast is applied over the insulation. Drain is fur-nished with a perforated stainless steel extension, made to the specified height of the insulation combined with the depth of the ballast. Large slotted dome providesmaximum free area for quick drainage of rainwater and protects the drain sump andconnected piping from debris. WEJLOC® compression flashing clamp holds the mem-brane or flashing securely to the drain body. With extra wide deck flange for positivesupport and large bonding surface for liquid applied membranes.

SPECIFICATIONJOSAM 21500-IRMA-6 Series coated cast iron Roof Drain, large polypropylene lockingdome, dome support ring, perforated stainless steel extension filter, WEJLOC® non-puncturing clamp ring and large sump with extra wide roof flange and bottom outletinside caulk connection.

OPTION N/A:-4

ROOF DRAINSROOF DRAINS

77

21500-IRMA SERIES LARGE SUMP with Perforated Stainless Steel Extension

21500-IRMA-6 SERIES LARGE SUMP with -6 Wide Flange & Perforated SS Extension

FOR OUTLET TYPE SPECIFY -XTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.21502-IRMA-6 2 77 21505-IRMA-6 5 8021503-IRMA-6 3 78 21506-IRMA-6 6 8121504-IRMA-6 4 79

CONFORMS WITH ASTM-C564.s "A" DIM. SPECIFY ON ORDER.l THIS DIM. IS 5-3/4" FOR 21508-IRMA-T.

s "A" DIM. SPECIFY ON ORDER

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.21502-IRMA 2 39 21506-IRMA 6 4321503-IRMA 3 40 21508-IRMA 8 4521504-IRMA 4 41 21509-IRMA-Z 10† 4621505-IRMA 5 42 †10” AVAILABLE IN NO-HUB ONLY.

ROO

FD

RAIN

S

Roof Drains_08.qxd 4/22/08 6:26 PM Page 77

APPLICATIONUsed on smaller roofs, gutters or valleys of any construction. Small diameter pan isparticularly adaptable to gutters and valleys where limited space is available.WEJLOC® compression flashing clamp holds the membrane or flashing to the drainbody. Small beehive dome provides ample drainage for small roof decks, gutters andvalleys, and intercepts debris.

SPECIFICATIONJOSAM 22080 Series coated cast iron Roof Drain with beehive dome, WEJLOC® non-puncturing clamp ring with integral gravel stop and small sump with roof flange andbottom outlet.

-1 Deck Clamp Assembly-1C Drain Receiver Clips

(Min. Deck Opening 10.75" Dia.)-2 Drain Receiver-3 Deck Clamp Assembly and

Drain Receiver-3C Drain Receiver and Drain

Receiver Clips-10 Fixed Extension Collar, Cast

Iron, (Specify Hgt) 1” Std.-10 -20 Fixed Ext. Collar, Galv.,

(Specify Hgt) 1” Std.-17 2" High Solid Clamping Collar

-20 Galvanized Cast Iron Parts-21 Galvanized Cast Iron Dome

Only-23 Rough Bronze Dome-VP Vandal-Proof Dome

OUTLETS:* -TSO Threaded Side Outlet

-T Threaded Outlet-X Inside Caulk Outlet-Y Hub Outlet w/Gasket-Z No-Hub Spigot Outlet

Available Options

APPLICATIONUsed on mid-sized roofs of any construction where a medium-sized drain is required.Flashing clamp holds the membrane or flashing securely to the drain body. Medium-sized beehive dome provides ample drainage for smaller roof decks and interceptsdebris.

SPECIFICATIONJOSAM 22010 Series coated cast iron Roof Drain, medium beehive dome, non-punc-turing clamp ring with integral gravel stop and medium sump with roof flange andbottom outlet.

-1 Deck Clamp Assembly-1C Drain Receiver Clips

(Min. Deck Opening 13.75" Dia.)-2 Drain Receiver-3 Deck Clamp Assembly and

Drain Receiver-3C Drain Receiver and Drain

Receiver Clips-10 Fixed Ext. Collar, Cast Iron,

(Specify Hgt) 1” Std.-10-20 Fixed Ext. Collar, Galvanized,

(Specify Hgt) 1” Std.-17 2" High Solid Clamping Collar

-19 Clamp Collar w/Perforated SSGravel Guard

-20 Galvanized Cast Iron Parts-21 Galvanized Cast Iron Dome

Only-23 Rough Bronze Dome-VP Vandal-Proof Dome

OUTLETS:-66 No-Hub Side Outlet-T Threaded Outlet-X Inside Caulk Outlet-Z No-Hub Spigot Outlet

ROOF DRAINSROOF DRAINS

78

ROO

FD

RAIN

S

FOR OUTLET TYPE SPECIFY -T, -X or -ZTYPE NO. PIPE SIZE D E LBS.

22012 2 4-3/4 6-1/4 3022013 3 4-3/4 6-1/4 3022014 4 4-1/2 6-1/4 3022015 5 4-3/8 6 3022016 6 4 5-3/4 30

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS.

22082 2 1322083 3 1322084 4 13

22010 SERIES MEDIUM SUMP, Beehive Dome

22080 SERIES SMALL SUMP, High Dome

Available Options

CONFORMS WITH ASTM-C564.

* Standard Drain Receiver cannot be used with -TSO option. Contact Factory. Deck Clamp cannot be used with - TSO option in 4” size.

Roof Drains_08.qxd 3/28/08 12:14 PM Page 78

APPLICATIONCombination Roof Drain/Overflow Drain. One-piece double drain receiver positionsroof drain, overflow drain side by side, requiring single deck penetration. Mediumsumps selected for anticipated flow. Combination non-puncturing clamp ring, gravelstop ensures watertight seal at the surface.

SPECIFICATIONJOSAM 22200 Series coated cast iron 12” diameter Combination Roof Drain andOverflow Drain, one WEJLOC® non-puncturing clamp ring with integral gravel stopand cast iron dome, one non-puncturing clamp ring with solid waterguard, doubledrain receiver and clips and cast iron beehive dome.

APPLICATIONUsed on small roofs, gutters or valleys of any construction. Integral outlets for roofand overflow drainage in one-piece body for limited space installation. WEJLOC®

compression flashing clamps hold the membrane or flashing to the drain body. Smallbeehive domes provide ample drainage for small roof decks and intercept debris.

SPECIFICATIONJOSAM 22100 Series coated cast iron combination Roof Drain and Overflow Drainwith cast iron domes, two WEJLOC® non-puncturing clamp rings with integral gravelstops, integral cast iron standpipe in cast iron deck flange and dual no-hub bottomoutlets.

-10 Fixed Extension Collar, Cast Iron,(Specify Hgt) 1” Std.

-20 Galvanized Cast Iron Parts-23 Rough Bronze Dome-28 Cast Iron Dome for Overflow Drain-33 Stainless Mesh Screen-Covered Dome

-VP Vandal-Proof Dome-IRMA Perforated Stainless Steel

ExtensionOUTLETS:

-Z No-Hub Spigot Outlets

APPLICATIONCombination Roof Drain/Overflow Drain. One-piece double drain receiver positionsroof drain, overflow drain side by side, requiring single deck penetration. Large sumpsselected for anticipated flow. Combination non-puncturing clamp ring, gravel stopensure watertight seal at the surface.

SPECIFICATIONJOSAM 22500 Series coated cast iron 15” diameter Combination Roof Drain andOverflow Drain, one WEJLOC® non-puncturing clamp ring with integral gravel stop,one WEJLOC® non-puncturing clamp ring with internal waterguard, double drainreceiver and clips and two large polypropylene locking domes.

-10 Fixed Extension Collar, Cast Iron,(Specify Hgt) 1” Std.

-20 Galvanized Cast Iron Parts-23 Rough Bronze Domes-33 Stainless Mesh Screen-Covered Domes-VP Vandal-Proof Domes

-IRMA Perforated Stainless SteelExtensions

OUTLETS:-T Threaded Outlets-X Inside Caulk Outlets-Z No-Hub Spigot Outlets

Available Options

Available Options

Available Options-10 Fixed Extension Collar, Cast Iron,

(Specify Hgt) 4” Std.-20 Galvanized Cast Iron Parts-23 Rough Bronze Domes-28 Cast Iron Dome for Overflow Drains-33 Stainless Mesh Screen-Covered Domes-VP Vandal-Proof Domes

-IRMA Perforated Stainless SteelExtensions

OUTLETS:-T Threaded Outlets-X Inside Caulk Outlets-Y Hub Outlets w/Gasket, 2”-4”-Z No-Hub Spigot Outlets

ROOF DRAINSROOF DRAINS

79

22200 SERIES MEDIUM SUMP, Combination Drain/Overflow

22500 SERIES LARGE SUMP, Combination Drain/Overflow

22100 SERIES SMALL SUMP, Combination Drain/Overflow

FOR OUTLET TYPE SPECIFY -ZTYPE NO. PIPE SIZE LBS.

22102 2 3722103 3 3722104 4 38

* 5-5/8" DIM. (BODY HGT.) VARIES BY OUTLET SIZE WITH -T AND -X CONNECTIONS.

FOR OUTLET TYPE SPECIFY -T, -X or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.22202 2 55 22205 5 5522203 3 55 22206 6 5522204 4 55

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.22502 2 65 22506 6 6522503 3 65 22508 8 6522504 4 65 22509-Z 10† 6522505 5 65 † 10” AVAILABLE IN NO-HUB ONLY

ROO

FD

RAIN

S

Roof Drains_08.qxd 3/28/08 12:14 PM Page 79

APPLICATIONUsed on promenade decks and roofs where foot traffic or light- to medium-weightvehicles will be present. Large square grate provides ample free area for properdrainage and has narrow slotted openings for pedestrian safety and for the intercep-tion of debris. WEJLOC® compression flashing clamp holds the membrane or flashingto the drain body.

SPECIFICATIONJOSAM 23500 Series coated cast iron Roof Drain, square pedestrian grate set insquare secured frame, WEJLOC® non-puncturing flashing collar with weepholes for 2"roof fill and large sump with wide roof flange and bottom outlet.

t -AE LEVELEZE® Adjustable Extensiont -IRMA Perforated Stainless Steel Ext.

-CR Clamping Drain Receiver-PG Parking Grate,

110 Sq. In. Free Area-1 Deck Clamp Assembly-1C Drain Receiver Clips

(Min. Deck Opening 16.5" Dia.)-2 Drain Receiver-3 Deck Clamp Assembly and

Drain Receiver-3C Drain Receiver and

Drain Receiver Clips-4 Secondary Flashing Clamp

(use with -AE only)t -6 Extra Wide Flange Drain Body,

(2" through 6", -X only)-10 Fixed Ext. Collar, Cast Iron,

(Specify Hgt) 4" Std.-10-20 Fixed Ext. Collar, Galvanized,

(Specify Hgt) 4"Std.

t -18 Extra Deep Sump-20 Galvanized Cast Iron Parts-36 Ductile Iron Grate

(Cast Iron Top Only)-37-50 Heavy-Duty Ductile Iron

Undergrate Laminated Top,Satin Finish Nikaloy

-37-51 Heavy-Duty Ductile IronUndergrate Laminated Top,Satin Finish Bronze

-50 Cast Iron Undergrate LaminatedTop, Satin Finish Nikaloy

-51 Cast Iron Undergrate LaminatedTop, Satin Finish Bronze

-VP Vandal-Proof GrateOUTLETS:

-66 No-Hub Side Outlet, 2"-6"-T Threaded Outlet-X Inside Caulk Outlet-Y Hub Outlet w/Gasket, 2”-4”-Z No-Hub Spigot Outlet

APPLICATIONUsed on promenade decks and roofs where foot traffic or light- to medium-weightvehicles will be present. Large square grate ensures ample free area for properdrainage and has narrow slot openings for pedestrian safety and the interception ofdebris. WEJLOC® compression flashing clamp holds the membrane or flashing to thedrain body. Extra-wide deck flange provides positive support and large bonding sur-face for liquid applied membranes.

SPECIFICATIONJOSAM 23500-6 Series coated cast iron Roof Drain, square pedestrian grate set in asquare secured frame, WEJLOC® non-puncturing flashing collar with weepholes for 2"roof fill and large sump with extra wide roof flange and bottom outlet, inside caulkconnection.

OPTIONS N/A:-CR, -1C, -2, -3, -3C, -4

Available Options

ROOF DRAINSROOF DRAINS

80

ROO

FD

RAIN

S

23500 SERIES LARGE SUMP, Promenade Top

23500-6 SERIES LARGE SUMP with -6 Extra Wide Flange Drain Body

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.23502 2 57 23506 6 5923503 3 57 23508 8 6123504 4 58 23509-Z 10† 6223505 5 58 †10” AVAILABLE IN NO-HUB ONLY.

23500 SLOT WIDTH 5/16"23500-50 SLOT WIDTH 1/4"23500-51 SLOT WIDTH 1/4"

CONFORMS WITH ASTM-C564.THIS DIM. IS 5-3/4" FOR 23508-T.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

23500-6 SLOT WIDTH 5/16"23500-6-50 SLOT WIDTH 1/4"23500-6-51 SLOT WIDTH 1/4"

t Product Illustration follows.

FOR OUTLET TYPE SPECIFY -XTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.23502-6 2 80 23505-6 5 8123503-6 3 80 23506-6 6 8223504-6 4 81

Roof Drains_08.qxd 5/2/08 1:05 PM Page 80

APPLICATIONUsed on promenade decks and roofs where foot traffic or light- to medium-weightvehicles will be present. Large square grate provides ample free area for properdrainage and has narrow slotted openings for pedestrian safety and for the intercep-tion of debris. Deep sump accommodates heavy flow. WEJLOC® compression flash-ing clamp holds the membrane or flashing securely to the drain body.

SPECIFICATIONJOSAM 23500-18 Series coated cast iron Roof Drain, square pedestrian grate set insquare secured frame, WEJLOC® non-puncturing flashing collar with weepholes, for2" roof fill, deep sump with wide roof flange and bottom outlet.

APPLICATIONUsed on promenade decks and roofs where foot traffic or light- to medium-weightvehicles will be present. Large square grate provides ample free area for properdrainage and has narrow slotted openings for pedestrian safety and for the intercep-tion of debris. WEJLOC® compression flashing clamp holds the membrane or flashingsecurely to the drain body. Adjustable top accommodates insulation of roof fill depthand ensures proper grate elevation at the finished deck surface.

SPECIFICATIONJOSAM 23500-AE Series coated cast iron LEVELEZE® Roof Drain, square pedestriangrate set in square secured frame, WEJLOC® non-puncturing flashing collar with weep-holes for 2" roof fill, bolted support ring, adjustable top with wide roof flange andlarge sump with anchor flange and bottom outlet.

ROOF DRAINSROOF DRAINS

81

23500-AE SERIES LARGE SUMP with -AE Threaded Adjustable Extension

23500-18 SERIES with -18 EXTRA DEEP SUMP

23500-AE SLOT WIDTH 5/16"23500-AE-50 SLOT WIDTH 1/4"23500-AE-51 SLOT WIDTH 1/4"

23500-18 SLOT WIDTH 5/16"23500-18-50 SLOT WIDTH 1/4"23500-18-51 SLOT WIDTH 1/4"

CONFORMS WITH ASTM-C564.THIS DIM. IS 5-3/4" FOR 23508-AE-T.

s WITH CLAMP RING 2-1/4" MIN. 4-1/4" MAX.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.23502-AE 2 82 23506-AE 6 8023503-AE 3 82 23508-AE 8 8023504-AE 4 81 23509-AE-Z 10† 8123505-AE 5 81 † 10” AVAILABLE IN NO-HUB ONLY

FOR OUTLET TYPE SPECIFY -X or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.23502-18 2 63 23505-18 5 6523503-18 3 63 23506-18 6 6623504-18 4 64

ROO

FD

RAIN

S

Roof Drains_08.qxd 3/28/08 12:14 PM Page 81

APPLICATIONUsed on promenade decks and roofs where pedestrian traffic will be present andwhere the "Insulated Membrane Assembly," also known as, "Inverted MembraneAssembly" is specified. Insulation is installed on top of the waterproof membraneand gravel ballast is applied over the insulation. Drain is furnished with a perforatedstainless steel extension, made to the specified height of the insulation combinedwith the depth of the ballast. Large square grate provides ample free area for properdrainage and has narrow slotted openings for pedestrian safety and for interceptionof debris. WEJLOC® compression flashing clamp holds the membrane or flashingsecurely to the drain body. With extra-wide deck flange for positive support andlarge bonding surface for liquid applied membranes.

SPECIFICATIONJOSAM 23500-IRMA-6 Series coated cast iron Roof Drain, square pedestrian grate setin square secured frame, frame support collar, perforated stainless steel extension fil-ter, WEJLOC® non-puncturing clamp ring and large sump with extra wide roof flangeand bottom outlet inside caulk connection.

OPTION N/A:-4

APPLICATIONUsed on promenade decks and roofs where pedestrian traffic will be present andwhere the "Insulated Membrane Assembly," also known as, "Inverted MembraneAssembly" is specified. Insulation is installed on top of the waterproof membraneand gravel ballast is applied over the insulation. Drain is furnished with a perforatedstainless steel extension, made to the specified height of the insulation combinedwith the depth of the ballast. Large square grate provides ample free area for properdrainage and has narrow slotted openings for pedestrian safety and for interceptionof debris. WEJLOC® compression flashing clamp holds the membrane or flashingsecurely to the drain body.

SPECIFICATIONJOSAM 23500-IRMA Series coated cast iron Roof Drain, square pedestrian grate setin square secured frame, frame support collar, perforated stainless steel extension fil-ter, WEJLOC® non-puncturing clamp ring and large sump with wide roof flange andbottom outlet.

OPTION N/A:-4

ROOF DRAINSROOF DRAINS

82

ROO

FD

RAIN

S

23500-IRMA SERIES LARGE SUMP with Perforated Stainless Steel Extension

23500-IRMA-6 SERIES LARGE SUMP with -6 Wide Flange & Perforated SS Extension

23500-IRMA SLOT WIDTH 5/16"23500-IRMA-50 SLOT WIDTH 1/4"23500-IRMA-51 SLOT WIDTH 1/4"

23500-IRMA-6 SLOT WIDTH 5/16"23500-IRMA-6-50 SLOT WIDTH 1/4"23500-IRMA-6-51 SLOT WIDTH 1/4"

s "A" DIM. SPECIFY ON ORDER.CONFORMS WITH ASTM-C564.THIS DIM. IS 5-3/4" FOR 23508-IRMA-T.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

s "A" DIM. SPECIFY ON ORDER.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.23502-IRMA 2 59 23506-IRMA 6 6123503-IRMA 3 59 23508-IRMA 8 6323504-IRMA 4 60 23509-IRMA-Z 10† 6423505-IRMA 5 60 † 10” AVAILABLE IN NO-HUB ONLY

FOR OUTLET TYPE SPECIFY -XTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.23502-IRMA-6 2 80 23505-IRMA-6 5 8123503-IRMA-6 3 80 23506-IRMA-6 6 8223504-IRMA-6 4 81

Roof Drains_08.qxd 3/28/08 12:14 PM Page 82

APPLICATIONUsed on roofs or decks designed for heavy traffic, such as parking decks and loadingdocks. Large round extra heavy-duty grate provides ample free area for properdrainage. WEJLOC® compression flashing clamp holds the membrane or flashingsecurely to the drain body.

SPECIFICATIONJOSAM 23510 Series coated cast iron Roof Drain, round extra heavy-duty grate set inround secured frame, WEJLOC® non-puncturing flashing collar with weepholes, for 2"roof fill and large sump with wide roof flange and bottom outlet.

APPLICATIONUsed on small- and medium-sized promenade deck areas and roofs where foot trafficor light- to medium-weight vehicles will be present. Medium-sized round grate set ina square frame provides ample free area for proper drainage and has narrow slottedopenings for pedestrian safety and for the interception of debris. Flashing clampholds the membrane or flashing securely to the drain body.

SPECIFICATIONJOSAM 23710 Series coated cast iron Roof Drain, round pedestrian grate set insquare secured frame, non-puncturing flashing collar with weepholes for 2" roof filland medium sump with roof flange and bottom outlet.

Available Options

Available Options

-CR Clamping Drain Receiver-1 Deck Clamp Assembly-1C Drain Receiver Clips

(Min. Deck Opening 16.5" Dia.)-2 Drain Receiver-3 Deck Clamp Assembly

and Drain Receiver-3C Drain Receiver and

Drain Receiver Clips-10 Fixed Ext. Collar, Cast Iron,

(Specify Hgt) 4" Std.-10-20 Fixed Ext. Collar, Galvanized,

(Specify Hgt) 4" Std.

-20 Galvanized Cast Iron Parts-36 Ductile Iron Grate

(Cast Iron Top Only)-50 Satin Finish Nikaloy Top-51 Satin Finish Bronze Top-VP Vandal-Proof Grate

OUTLETS:-T Threaded Outlet-X Inside Caulk Outlet-Y Hub Outlet w/Gasket 2"-4"-Z No-Hub Spigot Outlet

-1 Deck Clamp Assembly-1C Drain Receiver Clips (Min. Deck

Opening 13.75" Dia.)-2 Drain Receiver-3 Deck Clamp Assembly

and Drain Receiver-3C Drain Receiver and

Drain Receiver Clips-12 Extended Flashing Collar, Cast

Iron, (Specify Height) 1” Std.

-20 Galvanized Cast Iron Parts-50 Satin Finish Nikaloy Top-51 Satin Finish Bronze Top-VP Vandal-Proof Grate

OUTLETS:-66 No-Hub Side Outlet, 2"- 6"-T Threaded Outlet-X Inside Caulk Outlet-Z No-Hub Spigot Outlet

ROOF DRAINSROOF DRAINS

83

23510 SERIES LARGE SUMP with Extra Heavy-Duty Parking Grate

23710 SERIES MEDIUM SUMP, Promenade Top

1-1/16" SQ. HOLES

SLOT WIDTH 1/4"

THIS DIM. IS 5-3/4" FOR 23518-T.CONFORMS WITH ASTM-C564.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.23512 2 72 23515 5 7323513 3 72 23516 6 7423514 4 73 23518 8 76

FOR OUTLET TYPE SPECIFY -T, -X or -ZTYPE NO. PIPE SIZE D E LBS.

23712 2 4-3/4 6-1/4 3223713 3 4-3/4 6-1/4 3223714 4 4-1/2 6-1/4 3223715 5 4-3/8 6 3623716 6 4 5-3/4 36

ROO

FD

RAIN

S

Roof Drains_08.qxd 3/28/08 12:14 PM Page 83

APPLICATIONUsed on smaller-sized promenade deck areas and roofs where foot traffic or lightvehicles will be present. Smaller round grate set in a square frame provides amplefree area for proper drainage and has narrow slotted openings for pedestrian safetyand for the interception of debris. Flashing clamp holds the membrane or flashingsecurely to the drain body.

SPECIFICATIONJOSAM 23730 Series coated cast iron Roof Drain, round pedestrian grate set insquare secured frame, non-puncturing flashing collar with weepholes for 2" roof filland small sump with wide roof flange and bottom outlet

APPLICATIONUsed on smaller-sized promenade deck areas and roofs where foot traffic or vehicleswill be present. Heavy-duty ductile iron undergrate with Nikaloy top accommodatespedestrian traffic and large vehicles. Square holes provide ample free area for properdrainage, pedestrian safety and the interception of debris. Flashing clamp holds themembrane or flashing securely to the drain body.

SPECIFICATIONJOSAM 23740 Series coated cast iron Roof Drain, square heavy-duty ductile ironundergrate with Nikaloy top grate set in square secured frame, non-puncturingflashing collar with weepholes, for 2" roof fill and small sump with roof flange andbottom outlet.

Available Options

Available Options-1 Deck Clamp Assembly-1C Drain Receiver Clips (Min. Deck

Opening 10.25" Dia.)-2 Drain Receiver-3 Deck Clamp Assembly and

Drain Receiver-3C Drain Receiver and Drain

Receiver Clips-12 Extended Flashing Collar, Cast

Iron, (Specify Height) 1” Std.-12-20 Extended Flashing Collar, Galv.,

(Specify Height) 1” Std.

-20 Galvanized Cast Iron Parts-51 Satin Finish Bronze Top-VP Vandal-Proof Grate

OUTLETS:* -TSO Threaded Side Outlet

-T Threaded Outlet-X Inside Caulk Outlet-Y Hub Outlet w/Gasket-Z No-Hub Spigot Outlet

*Cannot be used with Drain Receiver.

-1 Deck Clamp Assembly-1C Drain Receiver Clips

(Min. Deck Opening 10.25" Dia.)-2 Drain Receiver-3 Deck Clamp Assembly

and Drain Receiver-3C Drain Receiver and

Drain Receiver Clips-12 Extended Flashing Collar, Cast

Iron, (Specify Height) 1” Std.-12 -20 Extended Flashing Collar,

Galv., (Specify Height) 1” Std.

-20 Galvanized Cast Iron Parts-50 Satin Finish Nikaloy Top-51 Satin Finish Bronze Top-VP Vandal-Proof Grate

OUTLETS:* -TSO Threaded Side Outlet

-T Threaded Outlet-X Inside Caulk Outlet-Y Hub Outlet w/Gasket -Z No-Hub Spigot Outlet

*Cannot be used with Drain Receiver.

ROOF DRAINSROOF DRAINS

84

ROO

FD

RAIN

S

23730 SERIES SMALL SUMP, Promenade Top

23740 SERIES SMALL SUMP, Heavy-Duty Promenade Top

SLOT WIDTH 3/16"

7/16" SQ. HOLES

CONFORMS WITH ASTM-C564.

CONFORMS WITH ASTM-C564.

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS.

23732 2 1823733 3 1823734 4 18

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS.

23742 2 1823743 3 1823744 4 18

Roof Drains_08.qxd 3/28/08 12:14 PM Page 84

APPLICATIONUsed on promenade roof decks where waterproof traffic-bearing elastomeric coveringis to be applied. Wide deck flange provides proper area for bonding of compositionroof deck covering and distributes the drain’s weight over a broad area for positivesupport. Mid-sized, round medium-duty SUPER-FLO® grate assures rapid drainageand protects drain and connected piping from debris.

SPECIFICATIONJOSAM 24020 Series coated cast iron SUPER-FLO® Roof Drain, round medium-dutyanti-tilting grate with perimeter drainage slots, set in round, non-puncturing mem-brane clamp ring and medium sump with 4" wide deck flange and bottom outlet,inside caulk connection.

APPLICATIONUsed on promenade roof decks where waterproof traffic-bearing elastomeric coveringis to be applied. Wide deck flange provides proper area for bonding of compositionroof deck covering and distributes the drain’s weight over a broad area for positivesupport. Large diameter, round medium-duty SUPER-FLO® grate assures rapiddrainage and protects drain and connected piping from debris. Non-puncturingmembrane clamp ensures proper seal between the drain body and the membrane.

SPECIFICATIONJOSAM 24030 Series coated cast iron SUPER-FLO® Roof Drain, round medium-dutyanti-tilting grate with perimeter drainage slots, set in round, non-puncturing mem-brane clamp ring and large sump with 4" wide deck flange and bottom outlet, insidecaulk connection.

Available Options

Available Options

-1 Deck Clamp Assembly-20 Galvanized Cast Iron Parts-29 Sediment Bucket, Cast Iron-29-20 Sediment Bucket, Galvanized-31 Chain Anchored Grate-36 Ductile Iron Grate

(Cast Iron Top Only)

-38 Less Grate-50 Satin Finish Nikaloy Top-51 Satin Finish Bronze Top-VP Vandal-Proof Grate

OUTLET:-X Inside Caulk Outlet

-1 Deck Clamp Assembly-20 Galvanized Cast Iron Parts-29 Sediment Bucket, Cast Iron-29 -20 Sediment Bucket, Galvanized-31 Chain Anchored Grate-36 Ductile Iron Grate

(Cast Iron Top Only)

-50 Satin Finish Nikaloy Top-51 Satin Finish Bronze Top-VP Vandal-Proof Grate

OUTLET:-X Inside Caulk Outlet

ROOF DRAINSROOF DRAINS

85

24020 SERIES MEDIUM SUMP, SUPER-FLO® Grate for Composition Deck

24030 SERIES LARGE SUMP, SUPER-FLO® Grate for Composition Deck

24020 SLOT WIDTH 3/8"24020-50 SLOT WIDTH 3/16"24020-51 SLOT WIDTH 3/16"

24030 SLOT WIDTH 9/16"24030-50 SLOT WIDTH 7/16"24030-51 SLOT WIDTH 7/16"

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

FOR OUTLET TYPE SPECIFY -XTYPE NO. PIPE SIZE LBS.

24022 2 2824023 3 2824024 4 29

FOR OUTLET TYPE SPECIFY -X

TYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.

24034 4 38 24036 6 42

24035 5 40 24038 8 45

ROO

FD

RAIN

S

Roof Drains_08.qxd 3/28/08 12:14 PM Page 85

APPLICATIONUsed on promenade roof decks or anywhere that an elastomeric or liquid appliedwaterproofing is to be used beneath a 2” pour of concrete or asphalt. Wide deckflange provides proper area for bonding of waterproofing material and distributes thedrain’s weight over a broad area for positive support. Mid-sized, round medium-dutySUPER-FLO® Grate assures rapid drainage and protects drain and connected pipingfrom debris. The 2” extension ensures that the grate and rim are flush with the fin-ished deck covering.

SPECIFICATIONJOSAM 24040 Series coated cast iron SUPER-FLO® Roof Drain, round medium-dutyanti-tilting grate with perimeter drainage slots, extension, medium sump with 4"wide deck flange and bottom outlet inside caulk connection.

APPLICATIONUsed in parking garages or docks for heavy traffic, where an elastomeric or liquidapplied waterproofing is to be applied beneath a 2” pour of concrete or asphalt.Wide deck flange provides proper area for bonding of composition roof deck coveringand distributes the drain’s weight over a broad area for positive support. Large diam-eter, round special-duty grate assures rapid drainage and protects drain and connect-ed piping from debris. The 2" extension ensures that the grate and rim are flush withthe finished deck covering.

SPECIFICATIONJOSAM 24050 Series coated cast iron Garage Drain with wide support flange, weep-holes, round special-duty grate and bottom outlet inside caulk connection.

Available Options

Available Options

-1 Deck Clamp Assembly-20 Galvanized Cast Iron Parts-29 Sediment Bucket, Cast Iron-29-20 Sediment Bucket, Galvanized-31 Chain Anchored Grate-36 Ductile Iron Grate

(Cast Iron Top Only)

-38 Less Grate-50 Satin Finish Nikaloy Top-51 Satin Finish Bronze Top-VP Vandal-Proof Grate

OUTLET:-X Inside Caulk Outlet

-1 Deck Clamp Assembly-12 Extended Flashing Collar,

Cast Iron, (Specify Hgt.) 1” Std.-20 Galvanized Cast Iron Parts-29 Sediment Bucket, Cast Iron-29-20 Sediment Bucket, Galvanized

-31 Chain Anchored Grate

-36 Ductile Iron Grate (Cast Iron Top Only)

-50 Satin Finish Nikaloy Top-51 Satin Finish Bronze Top-VP Vandal-Proof Grate

OUTLET:-X Inside Caulk Outlet

ROOF DRAINSROOF DRAINS

86

ROO

FD

RAIN

S

24040 SERIES MEDIUM SUMP, SUPER-FLO® Grate for Composition Deck

24050 SERIES LARGE SUMP, Special Duty Garage Drain

24040 SLOT WIDTH 3/8"24040-50 SLOT WIDTH 3/16"24040-51 SLOT WIDTH 3/16"

24050 SLOT WIDTH 1/2"24050-50 SLOT WIDTH 1/4"24050-51 SLOT WIDTH 1/4"

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

GRATE FREE AREA 61 SQ. IN.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

FOR OUTLET TYPE SPECIFY -XTYPE NO. PIPE SIZE LBS.

24042 2 3024043 3 3024044 4 30

FOR OUTLET TYPE SPECIFY -XTYPE NO. PIPE SIZE LBS.

24054 4 6124056 6 6124058 8 61

Roof Drains_08.qxd 4/22/08 6:34 PM Page 86

APPLICATIONUsed in parking garages or docks for heavy traffic, where an elastomeric or liquidapplied waterproofing is to be applied beneath a 2" pour of concrete or asphalt.Wide deck flange provides proper area for bonding of composition roof deck cover-ing and distributes the drain’s weight over a broad area for positive support. Largediameter, round special-duty SUPER-FLO® Grate assures rapid drainage and sedimentbucket protects drain sump and connected piping from debris.

SPECIFICATIONJOSAM 24060 Series coated cast iron Roof Drain, round special-duty grate and largesump with 4" wide deck flange and bottom outlet, inside caulk connection.

APPLICATIONUsed on promenade decks, plazas and recreational roof decks where foot traffic orlight-weight vehicles will be present and drainage is required from the deck surfaceand all layers of construction below to the waterproof membrane. Large slottedgrate provides ample free area for proper drainage and has narrow openings forpedestrian safety and for the interception of debris. The perforated outer ring servesas a form or retainer to hold the decking concrete, percolation layer aggregates andinsulation in place and can be made to the required height. It is perforated for alllevel drainage. The removable interior stainless steel filter prevents aggregates fromentering the drain and can be made to accommodate the thickness of the deck. Thebody has a deep sump for heavy flow and an extra wide deck flange for positive sup-port and large bonding surface for liquid applied membranes.

SPECIFICATIONJOSAM 24200 Series coated cast iron adjustable ALL-LEVEL Roof Drain, round pedes-trian grate set in round anchored frame leveled on adjustable threaded rods, remov-able perforated stainless steel filter, concrete forming and retaining ring and largesump with wide flange and bottom outlet inside caulk connection.

Available Options

Available Options

-1 Deck Clamp Assembly-20 Galvanized Cast Iron Parts-29 Sediment Bucket, Cast Iron-29-20 Sediment Bucket, Galvanized-31 Chain Anchored Grate

-50 Satin Finish Nikaloy Top-51 Satin Finish Bronze Top-VP Vandal-Proof Grate

OUTLET:-X Inside Caulk Outlet

-1 Deck Clamp Assembly-20 Galvanized Cast Iron Parts-VP Vandal-Proof Grate-50 Satin Finish Nikaloy Top-51 Satin Finish Bronze Top-60 Square Top, Cast Iron

-60-50 Square Top,Satin Finish Nikaloy

-60-51 Square Top,Satin Finish Bronze

OUTLET:-X Inside Caulk Outlet

ROOF DRAINSROOF DRAINS

87

24060 SERIES LARGE SUMP, Special-Duty Grate for Composition Deck

24200 SERIES LARGE SUMP, Promenade Top & Bonding Flange

1-1/16" SQ. HOLES

FOR OUTLET TYPE SPECIFY -XTYPE NO. PIPE SIZE LBS.

24064 4 6224066 6 6224068 8 63

24200 SLOT WIDTH 3/16"24200-50 SLOT WIDTH 1/4"24200-51 SLOT WIDTH 1/4"

nn "A" DIM. TO BE SPECIFIED ON ORDER. STD. 3" MAX. 12"GRATE FREE AREA – 30.2 SQ. IN.

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

FOR OUTLET TYPE SPECIFY -XTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.24202 2 53 24205 5 5624203 3 54 24206 6 5724204 4 55

ROO

F DRA

INS

Roof Drains_08.qxd 3/28/08 12:14 PM Page 87

APPLICATIONUsed in parapets, small balconies, sills, cornices, canopies, gutters and other smalloverhanging areas where drainage of rainwater through a 45° outlet is required.Flashing clamp design permits removal of dome strainer without disturbing flashingor waterproofing membranes.

SPECIFICATIONJOSAM 24500-45 Series coated cast iron Sill Drain, secured low bronze dome, bronzeclamp ring and shallow sump with flashing flange and 45º side outlet threadedconnection.

APPLICATIONUsed in parapets, small balconies, sills, cornices, canopies, gutters and other smalloverhanging areas where drainage of rainwater through a 90° side outlet is required.Flashing clamp design permits removal of dome strainer without disturbing flashingor waterproofing membranes.

SPECIFICATIONJOSAM 24500-90 Series coated cast iron Sill Drain, secured low bronze dome, bronzeclamp ring and shallow sump with flashing flange and 90° side outlet threadedconnection.

APPLICATIONUsed in parapets, small balconies, sills, cornices, canopies, gutters and other smalloverhanging areas where drainage of rainwater is required. Flashing clamp designpermits removal of dome strainer without disturbing flashing or waterproofingmembranes.

SPECIFICATIONJOSAM 24500 Series coated cast iron Sill Drain, secured low bronze dome, bronzeclamp ring and shallow sump with flashing flange and bottom outlet threadedconnection.

Available Optionst -45 Body with 45 Degree

Threaded Outlett -90 Body with 90 Degree

Threaded Outlet-20 Galvanized Cast Iron Parts-24 Rough Nikaloy Dome-27 High Dome-33 Stainless Steel Mesh Screen

Covered Dome

-35 Flat Grate-50 Satin Finish Nikaloy Top-51 Satin Finish Bronze Top-VP Vandal-Proof Dome

OUTLET:-T Threaded Outlet

ROOF DRAINSROOF DRAINS

88

ROO

F D

RAIN

S

24500 SERIES SHALLOW SUMP, Sill Type, Bronze Dome

24500-45 SERIES 45° Outlet 24500-90 SERIES 90° Outlet

FOR OUTLET TYPE, SPECIFY -T.

TYPE NO.PIPESIZE

DOMEFREEAREA SQ. IN. B C D E F H LBS.

24502-45 2 4.4 3-3/4 6 1-1/2 4-1/2 2-3/4 1-1/2 824503-45 3 7.3 4-3/4 7-1/4 1-1/2 4-3/4 2-3/4 1-7/8 1124504-45 4 7.3 4-3/4 7-1/4 2-3/8 5-5/8 2-1/8 1-7/8 11

FOR OUTLET TYPE, SPECIFY -T.

TYPE NO.PIPESIZE

DOMEFREEAREA SQ. IN. B C D E F H LBS.

24502-90 2 4.4 3-3/4 6 2-1/2 4 2-3/4 1-1/2 824503-90 3 7.3 4-3/4 7-1/4 3 5 3-1/2 1-7/8 1124504-90 4 7.3 4-3/4 7-1/4 3-1/2 6 3-1/2 1-7/8 11

24500-35 SLOT WIDTH 1/8"

2” AND 3” SIZE

4” SIZE

FOR OUTLET TYPE SPECIFY -TTYPE NO. PIPE SIZE LBS.

24502 2 424503 3 424504 4 5

t Product Illustration follows.

Roof Drains_08.qxd 3/28/08 12:14 PM Page 88

APPLICATIONUsed at the junction of the roof and the parapet where perimeter or emergency roofdrainage through a threaded side outlet is required. Sloping grate provides ampledrainage and is slotted to prevent entrance of debris. Flashing and membrane arepositively secured to the drain body with a compression clamp.

SPECIFICATIONJOSAM 24700 Series coated cast iron Roof Drain, parapet type, removable slopingbronze grate, flashing clamp, shallow sump with flashing flange and side outletthreaded connection.

Available Optionst -45 Body with 45 Degree

Threaded Outlet-20 Galv. Cast Iron Parts-22 Cast Iron Grate-24 Rough Nikaloy Grate

-50 Satin Finish Nikaloy Grate-51 Satin Finish Bronze Grate-61 Downspout Elbow, Cast Iron-61-20 Downspout Elbow,

Galvanized

ROOF DRAINSROOF DRAINS

89

24700 SERIES PARAPET TYPE, Sloping Grate

24700-45 SERIES PARAPET TYPE, Sloping Grate, 45° Outlet

FOR OUTLET TYPE SPECIFY -T

TYPE NO. A

GRATEFREEAREASQ. IN. BxB1 CxC1 D E F GxG1 HxH1 J K LxL1 LBS.

24702 2 19.5 4-1/2x11 6-1/2x11 1-1/2 6-3/8 5-5/8 3x5-1/8 4-1/8x5-1/4 7-3/8 1-1/4 3-1/4x5-1/4 2224703 3 19.5 4-1/2x11 6-1/2x11 2-1/8 6-3/8 5-5/8 3x5-1/8 4-1/8x5-1/4 7-3/8 1-1/4 3-1/4x5-1/4 2224704 4 19.5 4-1/2x11 6-1/2x11 2-5/8 6-3/8 5-5/8 3x5-1/8 4-1/8x5-1/4 7-3/8 1-1/4 3-1/4x5-1/4 2224705 5 34.3 5-1/2x13 7-1/2x13 3-1/2 8-1/8 6-5/8 4x6-1/8 5x7-1/2 10-3/4 1-3/4 4-1/4x7-1/2 2824706 6 34.3 5-1/2x13 7-1/2x13 3-1/2 8-1/8 6-5/8 4x6-1/8 5x7-1/2 10-3/4 1-3/4 4-1/4x7-1/2 28

ss DIM. 7/8" ON 2"-4" SIZES

APPLICATIONUsed at the junction of the roof and the parapet where perimeter or emergency roofdrainage through a threaded 45° outlet is required. Sloping grate provides ampledrainage and is slotted to prevent entrance of debris. Flashing and membrane arepositively secured to the drain body with a compression clamp.

SPECIFICATIONJOSAM 24700-45 Series coated cast iron Roof Drain, parapet type, removable slopingbronze grate, flashing clamp and shallow sump with flashing flange and 45º side out-let threaded connection.

FOR OUTLET TYPE, SPECIFY -T.

TYPE NO.PIPESIZE

GRATEFREEAREA SQ. IN. BxB1 CxC1 D E LBS.

24702-45 2 19.5 4-1/2X11 6-1/2X11 2-1/4 3-7/8 2424703-45 3 19.5 4-1/2X11 6-1/2X11 2-5/8 4-1/4 2524704-45 4 19.5 4-1/2X11 6-1/2X11 3 4-5/8 2624705-45 5 34.3 5-1/2X13 7-1/2X13 3-1/2 5 3024706-45 6 34.3 5-1/2X13 7-1/2X13 3-5/8 5-1/2 32

t Product Illustration follows.

ROO

F DRA

INS

Roof Drains_08.qxd 4/30/08 10:49 AM Page 89

APPLICATIONUsed at the junction of the roof and the parapet where perimeter or emergency roofdrainage through a threaded side outlet is required. Angle grate provides ampledrainage and is slotted to prevent entrance of debris. Flashing and membrane arepositively secured to the drain body with a compression clamp.

SPECIFICATIONJOSAM 24720 Series coated cast iron Roof Drain, parapet type, secured angle grateintegral with flashing clamp, shallow sump with flashing flange and side outletthreaded connection.

Available Optionst -45 Body with 45 Degree

Threaded Outlet-20 Galv. Cast Iron Parts-23 Rough Bronze Grate-24 Rough Nikaloy Grate-50 Satin Finish Nikaloy Grate

-51 Satin Finish Bronze Grate-61 Downspout Elbow, Cast Iron-61-20 Downspout Elbow,

Galvanized-VP Vandal Proof Grate

APPLICATIONUsed at the junction of the roof and the parapet to provide perimeter or emergencyroof drainage where a threaded 45° outlet is required. Angle grate provides ampledrainage and is slotted to prevent entrance of debris. Flashing and membrane arepositively secured to the drain body with a compression clamp.

SPECIFICATIONJOSAM 24720-45 Series coated cast iron Roof Drain, parapet type, secured anglegrate integral with flashing clamp and shallow sump with flashing flange and 45ºside outlet threaded connection.

ROOF DRAINSROOF DRAINS

90

FOR OUTLET TYPE SPECIFY -T

TYPE NO. A

GRATEFREEAREASQ. IN. BxB1 CxC1 D E F GxG1 HxH1 J K LxL1 LBS.

24722 2 25.9 4-1/2x11 6-1/2x11 1-1/2 6-3/8 5-5/8 3x5-1/8 4-1/8x5-1/4 7-3/8 1-1/4 3-1/4x5-1/4 2624723 3 25.9 4-1/2x11 6-1/2x11 2-1/8 6-3/8 5-5/8 3x5-1/8 4-1/8x5-1/4 7-3/8 1-1/4 3-1/4x5-1/4 2624724 4 25.9 4-1/2x11 6-1/2x11 2-5/8 6-3/8 5-5/8 3x5-1/8 4-1/8x5-1/4 7-3/8 1-1/4 3-1/4x5-1/4 2624725 5 41.3 5-1/2x13 7-1/2x13 3-1/2 8-1/8 6-5/8 4x6-1/8 5x7-1/2 10-3/4 1-3/4 4-1/4x7-1/2 3424726 6 41.3 5-1/2x13 7-1/2x13 3-1/2 8-1/8 6-5/8 4x6-1/8 5x7-1/2 10-3/4 1-3/4 4-1/4x7-1/2 34

24720 SERIES PARAPET TYPE, Angle Grate

24720-45 SERIES PARAPET TYPE, Angle Grate, 45° Outlet

FOR OUTLET TYPE, SPECIFY -T.

TYPE NO.PIPESIZE

GRATEFREEAREA SQ. IN. BxB1 CxC1 D E LBS.

24722-45 2 25.9 4-1/2X11 6-1/2X11 2-1/4 3-7/8 2424723-45 3 25.9 4-1/2X11 6-1/2X11 2-5/8 4-1/4 2524724-45 4 25.9 4-1/2X11 6-1/2X11 3 4-5/8 2624725-45 5 41.3 5-1/2X13 7-1/2X13 3-1/2 5 3024726-45 6 41.3 5-1/2X13 7-1/2X13 3-5/8 5-1/2 32

ss DIM. 7/8" ON 2", 3" AND 4" SIZES.

t Product Illustration follows.

ROO

F D

RAIN

S

Roof Drains_08.qxd 4/30/08 10:49 AM Page 90

APPLICATIONUsed at the junction of the roof and the parapet where perimeter or emergencydrainage of rainwater is required and a 135° cant is specified. Extra-large slopinggrate provides ample drainage and is slotted to prevent entrance of debris. Flashingand membrane are positively secured to the drain body with a compression clamp,with threaded side outlet.

SPECIFICATIONJOSAM 24900 Series coated cast iron Roof Drain, parapet type, secured bronze domeintegral with flashing clamp, flashing flange and side outlet threaded connection.

APPLICATIONUsed at the parapet wall as scupper for perimeter drainage or as an overflow drain.Sleeve may be flashed at parapet wall and is held firmly in place by the adjustablewall collar.

SPECIFICATIONJOSAM 25000 Series coated cast iron Roof Drain, parapet scupper-sleeve type, flash-ing clamp, tubular body with flashing flange and adjustable wall collar.

Available Options

Available Options

-20 Galvanized Cast Iron Parts-24 Rough Nikaloy Dome-50 Satin Finish Nikaloy Dome-51 Satin Finish Bronze Dome-61 Downspout Elbow, Cast Iron-61-20 Downspout Elbow, Galvanized-VP Vandal-Proof Dome

-20 Galvanized Cast Iron Parts-62 Ornamental Gargoyle, Cast Iron-62-20 Ornamental Gargoyle, Galvanized

ROOF DRAINSROOF DRAINS

91

ROO

F DRA

INS

25000 SERIES PARAPET SCUPPER SLEEVE

24900 SERIES PARAPET TYPE, Angle Dome

TYPE NO. W LBS.25001 9 2625002 13 3225003 17 3825004 21 45

FOR OUTLET TYPE SPECIFY -TTYPE NO PIPE SIZE B LBS.

24902 2 1-5/8 5824903 3 2-3/16 5724904 4 2-11/16 5524905 5 3-1/4 5324906 6 3-3/4 50

Roof Drains_08.qxd 3/28/08 12:14 PM Page 91

APPLICATIONUsed on roof areas to receive wastewater from air conditioning units, cooling towersand other mechanical equipment installed on the roof. The solid water dam preventsstorm water from entering the waste line. The internal dome strainer provides ampledrainage and prevents entry of debris into the large sump.

SPECIFICATIONJOSAM 25500 Series coated cast iron FLO-SEPTOR® Roof Drain, cast iron internaldome strainer, combined WEJLOC® non-puncturing clamp ring and solid water damand large sump with wide roof flange and bottom outlet.

APPLICATIONUsed as a parapet overflow or at the base of a wall where a concealed leader dis-charges rainwater to the ground. Nozzle design diverts water away from the building,eliminating wall stains. Wall flange covers rough opening and serves as an anchor.

SPECIFICATIONJOSAM 25010 Series cast bronze Downspout Nozzle, loose wall flange and inletthreaded connection.

Available Options

Available Options

-24 Rough Nikaloy-51 Satin Finish Bronze-BS Bird Screen

OUTLET:-T Threaded Outlet-Z No-Hub Spigot Outlet (Bronze Only)

-CR Clamping Drain Receiver-1 Deck Clamp Assembly-2 Drain Receiver-3 Deck Clamp Assembly

and Drain Receiver-20 Galvanized Cast Iron Parts

OUTLETS:-66 No-Hub Side Outlet-T Threaded Outlet-X Inside Caulk Outlet-Y Hub Outlet w/Gasket-Z No-Hub Spigot Outlet

ROOF DRAINSROOF DRAINS

92

ROO

FD

RAIN

S

25010 SERIES DOWNSPOUT NOZZLE

25500 SERIES LARGE SUMP, FLO-SEPTOR®

CONFORMS WITH ASTM-C564.

FOR OUTLET TYPE SPECIFY -T or -Z

TYPENO.

PIPESIZE

THREADED NO-HUBLBS.

B C D E A B C D E25012 *2* 4 3-3/8 6 2-5/8 2-3/8 3-5/8 3 5-7/16 5-3/8 6

25013 3 4 3-3/8 6 2-5/8 3-3/8 3-5/8 3-1/2 6-7/16 5-3/8 6

25014 4 5 3-7/8 7 2-5/8 3-3/4 3-5/8 4 7-7/16 5-1/2 8

25015 *5* 7-1/2 4-7/8 9 2-5/8 4-1/4 3-5/8 4-1/2 8-7/16 5-3/4 17

25016 6 7-1/2 4-7/8 9 2-5/8 4-3/4 3-5/8 5 9-7/16 5-3/4 16

25018 8 9-5/8 5-7/8 11 2-5/8 5-7/8 3-5/8 6 11-7/16 6-1/2 19

25019 10 11-1/4 6-3/4 12-3/4 2-5/8 6-7/8 3 6-7/8 13-1/16 6-1/2 18

25010-12 12 - - - - 7-7/8 3 7-7/8 15-1/16 6-1/2 24

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS.

25502 2 4925503 3 5025504 4 5125505 5 5225506 6 53

* For 2" size, 3" is furnished with a 3" x 2" Cast Iron BushingFor 5" size, 6" is furnished with a 6" x 5" Cast Iron Bushing

-T THREADED -Z NO-HUB

Roof Drains_08.qxd 5/2/08 6:19 PM Page 92

APPLICATIONUsed on roof areas to receive wastewater from air conditioning units, cooling towersand other mechanical equipment installed on the roof. The solid water dam preventsstorm water from entering the waste line. The internal dome strainer provides ampledrainage and prevents entry of debris into the small sump.

SPECIFICATIONJOSAM 25540 Series coated cast iron FLO-SEPTOR® Roof Drain, bronze internal domestrainer, combined non-puncturing clamp ring and solid water dam and small sumpwith roof flange and bottom outlet.

APPLICATIONUsed on roof areas to receive wastewater from air conditioning units, cooling towersand other mechanical equipment installed on the roof. The solid water dam preventsstorm water from entering the waste line. The internal dome strainer provides ampledrainage and prevents entry of debris into the medium sump.

SPECIFICATIONJOSAM 25520 Series coated cast iron FLO-SEPTOR® Roof Drain, cast iron internaldome strainer, combined non-puncturing clamp ring and solid water dam and mediumsump with roof flange and bottom outlet.

-1 Deck Clamp Assembly-2 Drain Receiver-3 Deck Clamp Assembly and Drain Receiver-20 Galvanized Cast Iron Parts

OUTLETS:* -TSO Threaded Side Outlet

-T Threaded Outlet-X Inside Caulk Outlet-Y Hub Outlet w/Gasket-Z No-Hub Spigot Outlet

* Cannot be used with Drain Receiver.

-1 Deck Clamp Assembly-2 Drain Receiver-3 Deck Clamp Assembly and Drain Receiver-20 Galvanized Cast Iron Parts

OUTLETS:-66 No-Hub Side Outlet-T Threaded Outlet-X Inside Caulk Outlet-Z No-Hub Spigot Outlet

Available Options

Available Options

ROOF DRAINSROOF DRAINS

93

25520 SERIES MEDIUM SUMP, FLO-SEPTOR®

25540 SERIES SMALL SUMP, FLO-SEPTOR®

FOR OUTLET TYPE SPECIFY -T, -X or -ZTYPE NO. PIPE SIZE D E LBS.

25522 2 4-3/4 6-1/4 3025523 3 4-3/4 6-1/4 3025524 4 4-1/2 6-1/2 3025525 5 4-3/8 6 3025526 6 4 5-3/4 30

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS.

25542 2 1625543 3 1725544 4 17

CONFORMS WITH ASTM-C564.

ROO

F DRA

INS

Roof Drains_08.qxd 3/28/08 12:14 PM Page 93

APPLICATIONUsed with all types of vertical drainage conductors, leaders, stacks, vent or soil lines,where contraction and expansion movements must be compensated for to preventrupturing of lines and damage to the building construction.

SPECIFICATIONJOSAM 26200 Series coated cast iron Expansion Joint, schedule 80 PVC sleeve, pack-ing gland with bolted pressure ring, male inlet and female outlet threaded connection.

APPLICATIONUsed as a counterflashing sleeve where the roofing membranes are terminated at thestack, which passes through the roof. Sleeve is threaded so that the stack may beextended to the desired elevation.

SPECIFICATIONJOSAM 26440 Series coated cast iron Stack Fitting with counterflashing recess,threaded stack and extension connections.

Available Options

Available Options

-20 Galvanized Cast Iron Parts

-20 Galvanized Cast Iron PartsSingle Thread Can Be Furnished When Specified on Order.

ROOF DRAINSROOF DRAINS

94

ROO

F D

RAIN

S

26200 SERIES EXPANSION JOINT

26440 SERIES STACK FLASHING FITTING

TYPE NO. PIPE SIZE B C LBS.26441-1/2 1-1/2 3-1/4 5-3/8 426442 2 3-1/4 5-3/8 326443 3 4-1/4 5-3/8 426444 4 5-1/2 5-3/8 626445 5 6-1/2 5-3/8 1026446 6 7-1/2 5-3/8 10

TYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.26202 2 9 26206 6 2026203 3 11 26208 8 3726204 4 12 26209 10 7026205 5 16

Roof Drains_08.qxd 4/30/08 10:50 AM Page 94

APPLICATIONUsed for vandal-proofing plumbing vents, which terminate at the roof level. Uniquedesign eliminates the possibility of sticks or other materials being either carelessly ormaliciously placed in the vent openings, thus causing stoppage of the drainage andvent system.

SPECIFICATIONJOSAM 26700 Series coated cast iron Vandal-Proof hooded Vent Cap, with large frost-proofopenings, counterflashing collar, deep protective hood and recessed securing screws.

APPLICATIONUsed as a counterflashing sleeve where roofing membranes are terminated at thestack, which protrudes through the roof. A caulk joint is made between the upperhub of the sleeve and stack, effectively waterproofing the entire assembly.

SPECIFICATIONJOSAM 26450 Series coated cast iron Stack Sleeve, with counterflashing and caulkingrecesses.

Available Options

Available Options

-20 Galvanized Cast Iron Parts

-20 Galvanized Cast Iron Parts-63 All Rough Bronze-65 All Rough Nikaloy

ROOF DRAINSROOF DRAINS

95

26450 SERIES VENT STACK FLASHING SLEEVE

26700 SERIES VANDAL-PROOF VENT CAP

TYPE NO. PIPE SIZE B LBS.26451-1/2 1-1/2 3 326452 2 3-1/2 326453 3 4-3/4 526454 4 5-5/8 626455 5 6-3/4 826456 6 7-3/4 9

TYPE NO.PIPESIZE

DOMEFREEAREA SQ. IN. B C D E F LBS.

26701-1/2 1-1/2 3.7 2-5/8 2 4-1/2 5-3/4 1 426702 2 6.8 3-1/4 2 5-1/4 5-3/4 1 526702-1/2 2-1/2 15.3 4-3/8 2-1/2 6-7/8 8-1/4 3/4 1226703 3 15.3 4-3/8 2-1/2 6-7/8 8-1/4 1-1/8 1226704 4 27.4 5-1/2 2-1/2 8 8-1/4 1-1/8 1326705 5 41.6 6-1/2 2-1/2 10-1/8 11-3/4 1-1/8 2226706 6 58.0 7-1/2 2-3/4 11-3/4 11-3/4 1-1/8 23

ROO

F DRA

INS

Roof Drains_08.qxd 3/28/08 12:14 PM Page 95

APPLICATIONUsed on roofs of any size, for any type of construction where a predetermined rate of flow has been specified to limit pipe sizing or flooding of undersized pre-existingstorm drainage systems. Adjustable calibrated vanes can be factory set to prescribedG.P.M. flow rates as required. Large slotted dome provides maximum free area forquick drainage of rainwater and protects the drain sump and connected piping fromdebris. WEJLOC® compression flashing clamp holds the membrane or flashing secure-ly to the drain body. LEVELEZE® adjustable extension accommodates insulation ofvariable thickness.

SPECIFICATIONJOSAM 28600-AE Series coated cast iron LEVELEZE® FLO-SET® Roof Drain, withlarge secured dome, adjusted calibrated Vandal-Proof vane collar, WEJLOC® non-puncturing clamp ring with stationary vanes and integral gravel stop, boltedsupport ring, adjustable top with wide roof flange, large sump with anchor flange,and bottom outlet.

APPLICATIONUsed on roofs of any size, for any type of construction where a predetermined rate offlow has been specified to limit pipe sizing or flooding of undersized pre-existingstorm drainage systems. Adjustable calibrated vanes can be factory set to prescribedG.P.M. flow rates as required. Large slotted dome provides maximum free area forquick drainage of rainwater and protects the drain sump and connected piping fromdebris. WEJLOC® compression flashing clamp holds the membrane or flashing secure-ly to the drain body.

SPECIFICATIONJOSAM 28600 Series coated cast iron FLO-SET® Roof Drain with large secured dome,adjusted calibrated Vandal-Proof vane collar, WEJLOC® non-puncturing clamp ringwith stationary vanes and integral gravel stop, large sump with wide roof flange, andbottom outlet.

t -AE LEVELEZE® AdjustableExtension

-CR Clamping Drain Receiver-1 Deck Clamp Assembly-1C Drain Receiver Clips (Min.

Deck Opening 16.5" Dia.)-2 Drain Receiver-3 Deck Clamp Assembly and

Drain Receiver-3C Drain Receiver and Drain

Receiver Clips-4 Secondary Flashing Clamp

(use with -AE only)

-10 Fixed Ext. Collar, Cast Iron,(Specify Hgt) 4"Std.

-10-20 Fixed Ext. Collar, Galvanized,(Specify Hgt) 4"Std.

-20 Galvanized Cast Iron Parts-23 Rough Bronze Dome-VP Vandal-Proof Dome

OUTLETS:-66 No-Hub Side Outlet-T Threaded Outlet\-X Inside Caulk Outlet-Y Hub Outlet w/Gasket, 2"-4"-Z No-Hub Spigot Outlet

Available Options

ROOF DRAINSROOF DRAINS

96

ROO

FD

RAIN

S

28600 SERIES LARGE SUMP, FLO-SET®

28600-AE SERIES LARGE SUMP, FLO-SET® with -AE Threaded Adjustable Ext.

CONFORMS WITH ASTM-C564.s WITH CLAMP RING 2-1/4" MIN., 4-1/4" MAX.

CONFORMS WITH ASTM-C564.

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.28602-AE 2 94 28605-AE 5 9328603-AE 3 94 28606-AE 6 9228604-AE 4 93

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.28602 2 56 28605 5 5828603 3 56 28606 6 6028604 4 56

t Product Illustration follows.

DRAIN FURNISHED PRE-SET AND VANDAL-PROOFED.WHEN ORDERING, SPECIFY FLOW RATE AND HEAD

DRAIN FURNISHED PRE-SET AND VANDAL-PROOFED.WHEN ORDERING, SPECIFY FLOW RATE AND HEAD

Roof Drains_08.qxd 4/22/08 6:39 PM Page 96

APPLICATIONUsed on roofs of any size, for any type of construction. Extra large slotted cast irondome ensures maximum free area for quick drainage of rainwater and protects thedrain sump and connected piping from debris. WEJLOC® compression flashing clampholds the membrane or flashing securely to the drain body.

SPECIFICATIONJOSAM 29112 Series coated cast iron Roof Drain with large cast iron dome, non-puncturing clamp ring with integral gravel stop, large sump with wide roof flangeand no-hub bottom outlet.

Available Options

APPLICATIONUsed on decks where vibration or noise occur. The neoprene gasket isolates vibrationand sound from mechanical equipment rooms, studios, music rooms or heavy manu-facturing areas and prevents transmission through the plumbing system.

SPECIFICATIONJOSAM 29000 Series coated cast iron Isolation Deck Drain with non-puncturing clampring for standpipe, with bottom outlet connection.

Available Options-CR Clamping Drain Receiver-1 Deck Clamp Assembly-1C Drain Receiver Clips

(Min. Deck Opening 16.5" Dia.)-2 Drain Receiver-3 Deck Clamp Assembly

and Drain Receiver-3C Drain Receiver and Drain

Receiver Clips

-17 2" High Solid Clamping Collar-20 Galvanized Cast Iron Parts

OUTLETS:-66 No-Hub Side Outlet, 2"-6"-T Threaded Outlet-X Inside Caulk Outlet-Y Hub Outlet w/Gasket, 2"-4"-Z No-Hub Spigot Outlet

-1 Deck Clamp Assembly-2 Drain Receiver-3 Deck Clamp Assembly

and Drain Receiver-10 Fixed Ext. Collar, C.I.,

(Specify Hgt.) 4" Std.-10-20 Fixed Ext. Collar, Galv.,

(Specify Hgt.) 4" Std.

-17 2" High Solid Clamping Collar-20 Galvanized Cast Iron Parts-VP Vandal-Proof Dome

OUTLET:-Z No-Hub Spigot Outlet

ROOF DRAINSROOF DRAINS

97

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.29002 2 39 29005 5 3929003 3 39 29006 6 3929004 4 39 29008 8 39

29000 SERIES ISOLATION DECK DRAIN

29112 SERIES EXTRA-LARGE SUMP

CONFORMS WITH ASTM-C564.THIS DIM. IS 5-3/4" FOR 23508-T.

FOR OUTLET TYPE SPECIFY -ZTYPE NO. PIPE SIZE LBS.

29112 12 77

ROO

FD

RAIN

S

Roof Drains_08.qxd 4/22/08 6:44 PM Page 97

98

FLOOR DRAINSFLOOR DRAINSFL

OO

RD

RAIN

S

The two-piece Floor Drain bodies which are designed to be combined with any adjustable strainers offered by JOSAM have proven features whichmake them the easiest and quickest drains of this type to install. The clean fine thread which is on all types of adjustable strainers provides uninter-rupted adjustment at any time during construction up to and including the time the floor is being poured. Exclusive features are described and shownbelow. For further details and specifications, refer to the specific series in this section.

SUPER-FLO® Features

WEEPHOLESWeepholes around doubledrainage flange for seepage.

JIFFEE-SETJOSAM Floor Drains feature JIFFEE-SET connections with MULTI-TITE® serviceweight (SV) soil pipe gaskets, conforming to ASTM Standard C564 in 2, 3, and 4inch sizes for labor-saving assembly to service weight cast iron, no-hub cast iron,PVC and ABS pipe. Merely lubricate gasket and pipe, set drain in place, pushdown until top of pipe contacts built-in stop and the joint is complete.

ADJUSTABLE STRAINERS FOR ALL APPLICATIONSAll adjustable Strainers and Accessories shown in theStrainer Section can be used with the 30000, 30000-PD,30000-TSO, 30002-ST, 30304-Z and 30500 Series DrainBodies. Strainers are offered for all types of floor finishesand applications. Adjustable strainer and body combina-tions are shown so that dimensional data can be obtainedfor installation and specification purposes.

COLLARInvertible collar provides extravertical adjustment for strainer.

KEYHOLEKeyhole slots assure quick assemblywithout removal of bolts.

PRIMER TAP1/2” Primer Tap Connection withplug, standard on some series,optional (-50) on others.

THREADSHeavy collar designed to acceptall JOSAM exclusively threadedstrainers.

WEJLOC®

Exclusive compression "wedge lock"provides positive non-puncturing bond ofwaterproofing membrane to drain.

Floor Drains_08.qxd 3/27/08 9:31 AM Page 98

37814 -Z -14

Outlet SizeOutlet Type, No-Hub Spigot OutletOption, Hinged Grate

99

FLOOR DRAINSFLOOR DRAINS

Unless optional materials are specified, standard material shown in Specification will be provided. Last digit indicates outlet size. Alladjustable strainers and accessories can be used with the 30000, 30000-PD, 30000-TSO, 30002-ST, 30304-Z and 30500 Series Drain Bodies.

EXAMPLE: Series No. 37810 Type No. 37814

How To Order Floor Drains

How To Order Floor Drain/Strainer Combinations

FLOOR DRAINS • Pictorial Selection GuideFLOOR DRAINS • Pictorial Selection GuideSTRAINERSA SERIESSUPER-FLO® Strainer

Page 110

AD SERIESFlashing Clamp Strainer

Page 110

AF SERIESVinyl Tile Strainer

Page 110

C SERIESNON-CLOG Strainer withIntegral Bucket

Page 111

D SERIESDome Strainer

Page 111

E SERIESTractor Strainer

Page 111

STRAINERSE1 SERIESExtended Rim Strainer

Page 112

E2 SERIESIndirect Waste Strainer

Page 112

E3 SERIESIndirect Waste Strainer

Page 112

F SERIESThreaded Cover Strainer,Secondary Grate

Page 113

F4/F6 SERIESRound Funnel Assemblies

Page 113

F8/F9 SERIESOval Funnel Assemblies

Page 113

30004 -Z -5A -2 -80

Outlet SizeOutlet Type, No-Hub Spigot OutletStrainer Size and TypeOptional Material, Satin Finish Bronze TopOption, Perforated Stainless Steel Basket

EXAMPLE: Series No. 30000-A Type No. 30004-5A

FLOO

RD

RAIN

S

Floor Drains_08.qxd 3/27/08 9:31 AM Page 99

FLOOR DRAINS • Pictorial Selection GuideFLOOR DRAINS • Pictorial Selection Guide

100

FLO

OR

DRA

INS

STRAINERSG SERIESSolid Hinged Cover

Page 114

H SERIESSecured Hinged Grate

Page 114

M SERIESOverflow Standpipe

Page 114

P SERIESWall Strainer

Page 115

R SERIESGutter Strainer

Page 115

S SERIESSUPER-FLO® Strainer

Page 115

STRAINERST SERIESHinged Grate

Page 116

W SERIESStrainer Extension

Page 116

WF6A/6S SERIESComposition Deck Strainers

Page 116

30802-4CPShallow Trap & Chrome-Plated Strainer

Page 123

30900-9ADWide Flange Body Assy.w/Flashing Clamp Strainer

Page 123

31000Body with 5" RoundNikaloy Strainer

Page 123

BODIES ONLY30000Body Assembly

Page 117

30000-PDSecurity Body Assy.for Prisons

Page 117

30000-TSOBody Assy. with Threaded Side Outlet

Page 118

30002-STBody Assy. with Shallow Trap

Page 118

30304-ZNo-Hub C.I. Body

Page 119

30500Body with Trap & Cleanout

Page 119

BODY / STRAINER COMBINATIONS30000-ABody Assy. with SUPER-FLO® Strainer

Page 120

30000-CBody Assy. with NON-CLOG Strainer

Page 120

30000-DBody Assy. with Dome Strainer

Page 120

30000-EBody Assy. with Tractor Strainer

Page 120

30000-E1Body Assy. with Extended Rim Strainer

Page 121

30000-E2Body Assy. with Indirect Waste Strainer

Page 121

Floor Drains_08.qxd 3/27/08 9:31 AM Page 100

FLOOR DRAINS • Pictorial Selection GuideFLOOR DRAINS • Pictorial Selection Guide

101

FLOO

RD

RAIN

S

BODY / STRAINER COMBINATIONS30000-PBody Assy. with Wall Strainer

Page 121

30000-RBody Assy. with Gutter Strainer

Page 121

30000-SBody Assy. with SUPER-FLO® Strainer

Page 122

30002-ST-ABody Assy. with Trap & SUPER-FLO® Strainer

Page 122

30304-Z-ANo-Hub C.I. Body with SUPER-FLO® Strainer

Page 122

30500-ABody w/Deep Trap & SUPER-FLO® Strainer

Page 122

ROUND-TOP DRAINS321009" Top, Medium-Duty Drain

Page 124

32100-399" Top with Solid Cast-Iron Cover

Page 124

32100-AE9" Top, Adjustable Collar

Page 125

32100-AE-LC1-889" Top, Key-Lock Drain,Adjustable Collar

Page 126

32100-AE-TG9" Top Tractor Drain,Adjustable Collar

Page 126

32100-TG9" Tractor Top Drain

Page 126

ROUND-TOP DRAINS32150Two 9" Top Blood Drains,Extra-Heavy-Duty Grate

Page 127

321609" Tractor Top Drain

Page 127

3220012-5/8" Top Medium-DutyDrain, SUPER-FLO® Grate

Page 128

32200-AE12-5/8" Top Medium-DutyDrain, Adjustable Collar

Page 129

32200-AE-SD12-5/8" Top Special-DutyDrain, Adjustable Collar

Page 130

32200-SD12-5/8" Top Special-DutyGarage Drain

Page 130

ROUND-TOP DRAINS3230012-5/8" Top Medium-DutyDrain, SUPER-FLO® Grate

Page 131

3233012-5/8" Top Medium-DutyDrain with Bucket

Page 132

32330-SD12-5/8" Top Special-DutyGarage Drain

Page 132

3471014-7/8" Top Parking Deck Drain

Page 133

3472014-7/8" Top Parking DeckDrain with Bucket

Page 133

3492021-1/8" Top Extra-Heavy-Duty, NON-CLOG Drain

Page 134

Floor Drains_08.qxd 3/27/08 9:31 AM Page 101

FLOOR DRAINS • Pictorial Selection GuideFLOOR DRAINS • Pictorial Selection Guide

102

FLO

OR

DRA

INS

SQUARE TOP DRAINS351008" Top Storage Room Drain

Page 134

35130-14-19" Top Equip. Room Drain,Hinged Grate, Deep Bucket35130 Secured C.I. Grate

Page 135

3517010-1/4" Top Medium-DutyDrain with Bucket

Page 136

3780012-1/4 Top Deck Drain,Heavy-Duty Grate

Page 136

3781012-1/4 Top Deck Drain,Heavy-Duty Grate

Page 137

3782012-1/4" Top Deck Drain,Heavy-Duty Grate & Bucket

Page 137

SQUARE TOP DRAINS W/TRAP & CLEANOUT3783012-1/4" Top Heavy-Duty,Hinged Latching Grate

Page 138

3784012-1/4” Boiler Room Drain,Heavy-Duty Grate

Page 138

3790014" Top Packing HouseDrain, Adjustable Collar

Page 139

3796016" Top Medium-DutyDrain, SUPER-FLO® Grate

Page 139

38040Boiler Room Drain with Cleanout

Page 140

38250ABasement Drain withBackwater Valve

Page 140

W/TRAP & CLEANOUT SPECIALTY DRAINS38420Garage Drain, NON-CLOGTop, Cleanout & Bucket

Page 141

38420-IGS14" Top Gas Drain, Trap,Cleanout, Seal & Bucket

Page 141

38620-40Garage Drain, HingedGrate, Cleanout & Bucket

Page 142

3864012-7/8" x 10-7/8" TopGarage Drain with Bucket

Page 142

3882015" x 13-1/8" Top & Bucket

Page 143

38830Packing House Drain,Bucket & C.O.

Page 143

SPECIALTY DRAINS3885022" x 14" Roadway Drain,Dome Strainer

Page 144

3893021" x 14-1/2" Top PackingHouse Drain, Integral Trap

Page 144

3924012-1/2" Top Can Wash Drain

Page 145

39600Planter Drain

Page 145

3972011" Top Composition Drain

Page 146

39960Area Drain, Hinged Grate

Page 146

Floor Drains_08.qxd 3/27/08 9:32 AM Page 102

103

FLOOR DRAINSFLOOR DRAINSFLO

OR

DRA

INS

How To Choose A Floor DrainAdequate and proper drainage of surface areas within and immediately adjacent to building structures is of prime importance. Careful considerationmust be given to these areas, particularly their size and shape, and the anticipated volume of drainage to be handled.

Drainage volume is governed by a number of factors, depending on the building type and its use. Some of the factors to be considered include waterdischarge from equipment, run-off from vehicles, condensate waste and emergency drainage. The drainage volume of surfaces outside the building isnormally based on rainfall factors for the geographical region in which the project is located. Exterior drains may be sized and placed using rainfalldata provided in this guide. After these considerations have been studied and the piping layout has been developed, the proper types and sizes ofdrains to service the requirements must be determined.

Floor and area drain selection involves several fundamental steps including determination of tops and outlet sizes to provide fast, efficient drainage.Next, the type of drain best suited for the application must be selected. Considerations here include location, drain material, floor construction, weightof traffic, presence of sediment and debris, backflow prevention and architectural aesthetics, which is particularly significant in finished areas. Finally,the outlet connections must be selected, based on the piping system used, hub and spigot, no-hub, threaded and so forth. The following technical datawill help you in making your selection.

LOCATIONThe location, for which a drain is required, plays an important role in the selection of the drain. Basements, boiler and equipment rooms, parkingand service areas, utility rooms, machine and processing areas, elevator pits, toilet and shower rooms, laundries, kitchens, cold storage areas andmany other locations must be equipped with floor drains.

COMPLIANCE WITH ADAIn order to comply with the American Disabilities Act (ADA), drains located in walking surfaces or along accessible routes must have grate openings nogreater than 1/2 in. (13 mm) in one direction. If the grate openings are elongated, then the openings must be oriented so that the long dimension isperpendicular to the dominant direction of travel.

SIZES OF TOPS & OUTLETSTop size of floor or area drain normally relates directly to the grate free area which is the total area of drainage openings in the grate for efficientdrainage. Interior floor drains should have a grate free area equal to 1-1/2 times the free area of the connecting pipe. Exterior area drains subject torainfall should have a minimum free area equal to 2 times the free area of the connecting pipe. This recommended ratio of free area to outlet size(connecting pipe size) is per Floor Drain Standard ANSI A112.21.1M-1980.

FLOW RATE CALCULATIONIf the water pressure head above the floor and the required flow rate are known, the required grate free area of the drain can be calculated using thefollowing equation:

Q = 448.2•Cd• A• 2• g• h where Q = Flow Rate (Gallons per Minute)Cd = Discharge Coefficient = 0.6A = Free area [open area] of grate (ft/s2)g = Acceleration (32.2 ft/s2)h= Head above the floor (ft)

This equation can be solved for A: A = Q448.2•Cd • 2• g• h

An Example: A head of 0.5 in. (÷ 12 = h in ft. .006 ft.) above the floor with a required flow rate of 15 gallons per minute and an average dischargecoefficient of 0.6 gives a required grate free area of 0.034 sq. ft. [4.92 sq. in.].

AESTHETICSThe floor drain is aesthetically pleasing when the proper top material and shape are specified to harmonize with the surrounding environment.JOSAM features products that can be specified and installed with confidence and pride.

Floor Drains_08.qxd 3/27/08 9:32 AM Page 103

104

FLOOR DRAINSFLOOR DRAINSFL

OO

RD

RAIN

S

How To Choose A Floor Drain (continued)CONNECTIONSThe means by which the drain becomes an integral component of the drainage system must be carefully considered so that specifications will reflectproper outlets compatible to both the piping material and layout. There are five basic outlet connections: inside caulk, hub (outside caulk), no-hub,spigot and threaded. These connections are provided on the three common outlet types: bottom, side, and side with integral trap. There are a fewpointers relative to connections that should be kept in mind. Inside caulk connections (-X) can be made with any type of pipe using JOSAM JIFFEE-JOINTS more quickly and economically than with conventional caulking materials and methods. Hub (outside caulk) connections (-Y) can be made to soil pipe using the popular JIFFEE-SET compression gasket. Spigot connections can be joined with soil pipe hubs usingcompression gaskets or to no-hub using the conventional couplings. Specific details on outlet connections and types are included with the

product listings in this section.

FLOOR CONSTRUCTIONDrain selection is influenced by floor construction. Elements such as slab type and thickness, surface finish, depth of fill, finished floor materialsand waterproofing requirements are primary considerations. Installation diagrams illustrating various types of drains are included in this section to help you choose the right drain.

MATERIALSAfter the duty type is determined, top materials must be considered. The basic material used in the manufacture of floor drain grates is cast iron,conforming to ASTM Specification A48. Cast iron grates are suitable for most duty types in areas where aesthetics is not a factor. In such locationswhere shock or impact loading will be encountered, ductile iron grates should be specified as this material not only possesses superior strength butwill yield rather than fracture under severe service conditions. For installations where appearance and service are important, tops of bronze orNikaloy should be considered. These materials are usually accepted for exposed components of all plumbing drainage products in finished areas.Most heavy-duty types are available with non-ferrous tops over iron grates for those finished areas where service loading is anticipated. Detailedinformation on materials is presented in the Materials and Finishes section of this book and optional top materials are shown with specific series.

WEIGHT LOADSApart from their primary purpose of receiving and conveying liquids, floordrains, as integral components of the floor, must be structurally suitable to with-stand the anticipated loads that will be imposed on the floor. Weight supportrequirements of the drain vary with the location, construction, and service con-dition. The top loading classifications as published in Floor Drain Standard ANSIA112.21.1M-1980 are as follows:

Light-Duty– All grates testing under 2000 lb. (900 kg.).

Medium-Duty – All grates testing between 2000 lb. (900 kg.) and 4999 lb. (2250 kg.).

Heavy-Duty– All grates testing between 5000 lb. (2250 kg.) and 7499 lb. (3375 kg.).

Extra Heavy-Duty– All grates testing between 7500 lb. (3375 kg.) and 10,000 lb. (4500 kg.).

Special-Duty– Grates testing over 10,000 lb. (4500 kg.) should be considered special and treated accordingly.

When the top loading requirements for a drain have been determined, the dutytype needed can be resolved. Selection is easily accomplished as all JOSAMFloor Drains are classified according to duty type in this section. For specificdetail loading data, contact JOSAM Engineering.

Floor Drains_08.qxd 3/27/08 9:32 AM Page 104

105

FLOOR DRAINSFLOOR DRAINSFLO

OR

DRA

INS

How To Choose A Floor Drain (continued)TRAPPING OF SEDIMENTIn many locations, drainage will include sediments of various types which will eventually clog the drain lines if not trapped. Leaves, twigs,paper scraps, sand, machine cuttings, hair and lint are some of the more common types. Floor drains with sediment buckets should be specifiedin any location where the potential danger of drain stoppage due to sediment exists. Throughout this section, a comprehensive line of drainsfeaturing sediment buckets of every type will be found. Selection will depend upon the type of sediment to be trapped. One further point toconsider is that in shower and toilet rooms small valuables, such as rings, sometimes find their way to the drains. Sediment buckets or basketsin drains in these locations will make it possible to retrieve these items.

BACKFLOW PREVENTIONProtection against backflow from sewers is essential in basements and other areas located below the curb or property elevation where gravitydrainage to the main sewer is planned. Drains with backwater valves should also be considered in locations above the main sewer such assecond floor toilet rooms when an independent backwater valve cannot be installed in the line to prevent backflow from the floors above if ablockage should occur in the main waste stack. JOSAM features backwater valves of various types as either standard or optional equipment inmany cataloged floor drains. Closely related to protection against backflow is protection against the infiltration of sewer gas. This is accom-plished by traps either integral with or auxiliary to floor drains. Such drains with both backwater valves and deep seal traps provide total pro-tection of health and property while performing their primary drainage function. Where floor drains with integral or auxiliary traps will besubject to infrequent use, which could result in trap seal evaporation, they should be equipped with trap primer connections.

CODE COMPLIANCEThorough familiarization with plumbing codes in the area where the installation is being planned is recommended. Many factors relating to plumbing drainage products and their installations are governed by code. Our representatives will be happy to answer any questions regardingcode compliance of JOSAM products.

BALL FLOATVERTICAL

SWING CHECK

EXAMPLES OF BACKWATER VALVES

EXAMPLES OF SEDIMENT BUCKETS

Floor Drains_08.qxd 3/27/08 9:32 AM Page 105

106

FLOOR DRAINSFLOOR DRAINSFL

OO

RD

RAIN

S

LOCATIONType of building, number of floors and type of room play an importantrole in determining drain selection.

EXAMPLE:

Mechanical Room A non-public area, requiring drainage fromequipment or during cleaning processes.

COMPLIANCE TO ADADrainage Product compliance is not typically required in non-public areas.

EXAMPLE:

Slot width not a factor, so all drains are still applicable.

SIZE OF TOPS AND OUTLETSThe catalog is presented in the following order:

Two-piece floor drain with adjustable strainers for all applications, Roundtops from 9-21", Square Tops from 8-16" and drains for special applications.

EXAMPLE:

Typical Mechanical Rooms are small in size; round tops often pre-ferred to square to eliminate need for drain orientation to matchroom orientation.-Select 32100 -Select 32200 if outlet required is greater than 4"

FLOW RATE REQUIREMENTBased on grate free area, drainage area and outlet size.

EXAMPLE:

32100 free area is more than 1-1/2 times the opening of 4" pipe required.-Select 32200 to meet same criteria if 6" outlet required.

AESTHETICSAll Josam Company products go through several quality controlprocedures to ensure that the drains are provided with a uniform finish.

EXAMPLE:

Standard Cast Iron finish is all that is required. -Select 32100-Select optional Nikaloy top for finished appearance

CONNECTIONSOutlet Connections are often selected by local code or designer/installerpreference.

EXAMPLE:

Selected 32100 available in No-Hub, Caulk, Push-On Gasket orThreaded Outlet connection

FLOOR CONSTRUCTIONThe material requirement, type of waterproofing and depth of the floorare to be considered during the selection process.

EXAMPLE:

Mechanical Room is located on the second floor. Installation of waterproof membrane requires floor drain with clamp device. -Selected 32100 has WEJLOC ® non-puncturing clamp collar as a standard feature.

MATERIALSWhether the material is cast iron, stainless steel or plastic, JosamCompany offers many choices to meet the design criteria.

EXAMPLE:

Cast Iron Top, Cast Iron Body ensures long lasting installationwith consideration to cost

WEIGHT LOADSASME Standard 112.6.3-2001 categorizes load designations from SafeLive Load (1/2 the weight load of grate failure)

EXAMPLE:

Medium-duty rating on 32100 is adequate for Mechanical Room. -Select 32100-TG if accessible to heavier traffic

TRAPPING OF SEDIMENTPreventing debris from entering drainage system is the bucket’sprimary function.

EXAMPLE:

Interior installation often eliminates requirement for optional (-81) bucket

BACKFLOW PREVENTIONAreas prone to high water tables often require internal or external

backwater valves.

EXAMPLE:

Second-story installations don’t often require such device.

CODE COMPLIANCEJosam Company products are designed to comply with widely

accepted national plumbing standards, but ultimate code compliance

to be determined by local code official.

EXAMPLE:

32100 meets ANSI standard for Floor Drains A112.21-1M-1991

Drain Selection ProcessThe proper selection of a drainage product is based on several factors. This engineer catalog is designed to allow the specifier to select the proper drainageproduct with a logical progression of answers to the following questions. Below is a typical example of the selection process.

Floor Drains_08.qxd 3/27/08 9:32 AM Page 106

107

FLOOR DRAINSFLOOR DRAINSFLO

OR

DRA

INS

Typical InstallationsJOSAM Floor Drains incorporate features developed and tested to meet the requirements of all types of modern floor and surface constructionrelated to our industry and the plumbing drainage systems involved. These features ensure the specifier, installer and user of completely trouble-free installation and performance. The illustrations below show various types of floor drains installed in typical floor and exterior surface areas.

30000-A Series SUPER-FLO® Adjustable Strainer Floor Drain showninstalled in a concrete finish floor of two-pour construction. The versatileJIFFEE-JOINT Gasket makes the caulk connection to the drainage line.

30000-E1 Series Adjustable Strainer Floor Drain shown installed in a con-crete finish floor of two-pour construction. Extended rim protrudes 1 inchabove finish floor and serves as a receptacle for the emptying of liquids.

30000-WF6S Series SUPER-FLO® Adjustable Strainer Floor Drain showninstalled in a composition deck floor. Wide flange assures that bondingof floor material is watertight and permanent.

32100-81 Series SUPER-FLO® Floor Drain shown installed in a medium-duty single-pour concrete floor supported by steel construction.

32100-AE-81 Series SUPER-FLO® Floor Drain shown installed in apoured concrete floor with floor finish. LEVELEZE® Adjustable Collarprovides vertical adjustment, facilitating installation and forming a per-fect surface between top of drain and floor finish.

39600 Series Planting Area Drain shown in a typical installation providingdrainage for an indoor planting area. Stainless mesh screen covered domeprevents entrance of dirt and gravel at the base of the planting area.

Floor Drains_08.qxd 3/27/08 9:32 AM Page 107

108

FLOOR DRAINSFLOOR DRAINS

The optional features shown below illustrate a few of the options in the floor drain line. These options, as well as others, are offered to satisfy anyconstruction requirement where a floor drain is specified. Refer to specific series for available options. To order options, add suffix in ( ) to type number.

Options

(-19) OPTION, CAST IRON UNDERGRATEWITH SATIN NIKALOY TOP

(-20) OPTION, CAST IRON UNDERGRATEWITH SATIN BRONZE TOP

On many series of heavy-duty and extraheavy-duty drains, JOSAM offers theseoptions. In most cases, it isn’t practical when a heavy-duty grate option is needed ina finished area to provide the heavy-dutygrate totally in Nikaloy or bronze. The lami-nated top will give the finished appearancedesired while the heavy-duty cast iron under-grate will provide the required support.

(-49) OPTION, 3/4" PRIMER TAP(-50) OPTION, 1/2" PRIMER TAP

Any time the system is designed with a trapto prevent escape of sewer gas or vermin into the building, a trap seal primer connec-tion must be provided with the floor drain.When the primer piping is properly installedin conjunction with JOSAM’s 88250 SeriesTrap Seal Primer, the maintenance of the seal is assured.

(-66) OPTIONThis option converts JOSAM bottom outletinside caulk drains to no-hub side outletdrains using a 90˚ no-hub quarter bend and aJIFFEE-JOINT Gasket.

(-84) OPTION, STAINLESS STEEL MESH BUCKET LINER

In areas such as breweries, machine shops, orother facilities where small particles of glass,metal or other minute pieces of material will beencountered, a bucket liner should be used inconjunction with the sediment bucket. Thisoption will assure free-flowing drain lines andwill eliminate costly removal of blockage.

(-88) OPTION, SUPPLEMENTARY STRAINER

This option provides a secondary means ofprotection against blockage of drain lines.The openings in the supplementary strainerare smaller than the openings in the topgrate, allowing it to intercept debris enteringthe interior of the drain. This option isprimarily used in drains which don’t offer asediment bucket.

(-80) OPTION, PERFORATED STAINLESSSTEEL BASKET

For use with all adjustable strainers to collectdebris which may clog the waste line.

PIPESIZE A B

2 2-1/2 4-1/23 2-13/16 54 3-1/2 5-1/25 4-5/16 6-1/26 4-13/16 7

FLO

OR

DRA

INS

Floor Drains_08.qxd 3/27/08 9:32 AM Page 108

109

FLOOR DRAINSFLOOR DRAINS-44 Option, Fixed Extension Collar

(-AE) Option, LEVELEZE® Adjustable Extension

The adjustable integral top is mated to the body and support ring witha heavy machined thread which permits virtually unlimited top leveladjustment to accommodate various deck thicknesses. The line contactbetween the threads provides positive circumferential support of thetop at any adjusted elevation.

Outlet ConnectionsJOSAM drains are furnished with outlets for connection to most types of pipe. The timesaving, economical JIFFEE-JOINT Gasket is used for inside caulkconnections (-X) to extra heavy or service weight soil pipe. No-hub spigot outlets (-Z) are also available for connection to no-hub soil pipe. The JIFFEE-SETOutlet (-Y) is for connecting hub outlet drains to PVC and ABS, service weight or no-hub soil pipe. Threaded outlets (-T) can be obtained on many series.

OPTIONAL JOSAM JIFFEE-JOINT

CONVENTIONAL CAULK(BY OTHERS)

(-X) INSIDE CAULK CONNECTION (-Y) HUB CONNECTION (-T) THREADED CONNECTION (-Z) NO-HUB CONNECTION

OPTIONAL JOSAMJIFFEE-SET GASKET

NO-HUBCONNECTOR(BY OTHERS)

ORDERING INFORMATION

To specify or order a fixed extension collar with floor drain, add Option (-44) and height required to type number of drain.

Example: Type 32103 with a 6" extension would be designated: Type32103 (-44)-6".

SERIES NO. B D EIn. In. Min.

32100, 32150, 32160 9-1/8 8-1/8 232200, 32300 12-5/8 11-3/4 2

(-J) Option Backwater Valve

For use in any Josam adjustable strainer in areas subject to back flow conditions with the exception of Series C and M. Cannot be used in conjunc-tion with (-80) Option, Perforated Stainless Steel Basket.

A Series Round Strainer shown withOptional (-J) Backwater Valve

E Series Round Tractor Strainer shown withOptional (-J) Backwater Valve

S Series Square Strainer shown withOptional (-J) Backwater Valve

FLOO

RD

RAIN

S

Floor Drains_08.qxd 3/27/08 9:32 AM Page 109

APPLICATIONFor use in finished areas with pedestrian traffic such as supermarkets or kitchens.

-2 Satin Bronze Top-VP Secured Grate, Vandal-Proof Screws

APPLICATIONFor use in finished areas with pedestrian traffic such as toilet and shower rooms.

Available Options-SS Stainless Steel, 5A, 6A, 7A, 8A-2 Satin Finish Bronze-80 Perforated Stainless Steel Basket-CP Chrome Plated, 5A, 6A-J Backwater Valve-VP Secured Grate, Vandal-Proof Screws

APPLICATIONFor use in areas where a vinyl tile, liquid or trowel applied floor covering is to beadhered to the strainer flange and pedestrian traffic is expected.

-2 Satin Finish Bronze-80 Perforated Stainless Steel Basket-J Backwater Valve-VP Secured Grate, Vandal-Proof Screws

Available Options

Available Options

FLOOR DRAINS • StrainersFLOOR DRAINS • Strainers

110

FLO

OR

DRA

INS

TYPE NO. A B C D FREE AREA LBS.5A 5 1-15/16 1-1/8 4-5/8 7.8 26A 6 2-1/4 15/16 5-1/4 11.0 37A 7 2-11/16 1-1/2 6-7/16 13.2 48A 8 2-1/2 7/8 7-1/8 16.2 59A• 9 2-1/4 1 8-1/8 21.1 7

10A• 10 2-1/4 1-1/8 9 28.0 9•Not SUPER-FLO® Design

TYPE NO. FREE AREA LBS.6AD 10.4 4

TYPE NO. FREE AREA LBS.6AF 10.4 5

A SERIES ROUND NIKALOY SUPER-FLO® STRAINER

AD SERIES ROUND NIKALOY STRAINER with Clamp Device

AF SERIES ROUND NIKALOY STRAINER with Tile Flange

Floor Drains_08.qxd 3/27/08 9:32 AM Page 110

APPLICATIONFor use in areas subject to the accumulation of debris on the floor, which may causethe drain line to clog and where pedestrian traffic is expected such as public restrooms. Bucket is easy to remove and clean.

-2 Satin Finish Bronze Top-VP Secured Grate, Vandal-Proof Screws

APPLICATIONFor use in gutters and recessed areas where excessive debris build-up is expectedsuch as laundry rooms. Dome ensures drainage even when partly covered.

APPLICATIONFor use in finished floors where medium-weight wheeled loads are anticipated and a“tractor” type non-tilt grate is desired, such as commercial kitchens.

-2 Satin Finish Bronze-80 Perforated Stainless Steel Basket-93 Cast Iron Strainer, 7E-J Backwater Valve-VP Secured Grate, Vandal-Proof Screws

-2 Satin Finish Bronze-80 Perforated Stainless Steel Basket-J Backwater Valve-VP Secured Dome, Vandal-Proof Screws

Available Options

Available Options

Available Options

FLOOR DRAINS • StrainersFLOOR DRAINS • Strainers

111

FLOO

RD

RAIN

S

TYPE NO. FREE AREA LBS.5C 4.5 3

TYPE NO. A B C D EFREE AREA LBS.

5D 5 1-7/8 1 1-7/8 4-3/4 8.1 26D 6 2-1/4 1 1-3/4 5-1/4 8.1 3

TYPE NO. A B C D FREE AREA LBS.6E 6 3-3/8 1 5-1/4 6.7 57E 7 3 1-1/8 6-1/2 12.0 69E 9 3-1/8 7/8 8-1/4 21.2 11

C SERIES NON-CLOG STRAINER with Integral Bucket

D SERIES ROUND NIKALOY DOME STRAINER

E SERIES ROUND NIKALOY TRACTOR STRAINER

Floor Drains_08.qxd 4/24/08 9:08 AM Page 111

APPLICATIONFor use in non-traffic areas where the extended rim strainer will contain spills or con-densate waste, such as under ice machines. The recessed grate prevents poured liq-uids from flooding and splashing.

APPLICATIONFor use in non-traffic areas where the round funnel contains condensate drip, andgrate openings evacuate liquid spills from the surrounding floor, such as under steamtables.

APPLICATIONFor use in non-traffic areas where the oval funnel contains condensate drip frommore than one source, and grate openings evacuate liquid spills from the surroundingfloor, such as under commercial kitchen equipment.

-2 Satin Finish Bronze-80 Perforated Stainless Steel Basket-J Backwater Valve-VP Secured Grate, Vandal-Proof Screws

-2 Satin Finish Bronze-80 Perforated Stainless Steel Basket-J Backwater Valve-VP Secured Grate, Vandal-Proof Screws

-2 Satin Finish Bronze-80 Perforated Stainless Steel Basket-J Backwater Valve-VP Secured Grate, Vandal-Proof Screws

Available Options

Available Options

Available Options

FLOOR DRAINS • StrainersFLOOR DRAINS • Strainers

112

FLO

OR

DRA

INS

TYPE NO. A B C D H FREE AREA LBS.6E1 5-3/4 3-3/8 1 5-3/8 1-1/4 4 57E1 7-1/8 3 1-1/8 6-3/8 1 8.2 79E1 8-7/8 3-1/8 7/8 8-3/8 1-1/2 21.2 9

TYPE NO. LBS.7E2 8

TYPE NO. LBS.7E3 8

E1 SERIES ROUND NIKALOY STRAINER with Extended Rim

E2 SERIES ROUND NIKALOY STRAINER with Round Funnel

E3 SERIES ROUND NIKALOY STRAINER with Oval Funnel

Floor Drains_08.qxd 4/24/08 9:08 AM Page 112

APPLICATIONFor use in pedestrian traffic areas where drainage is not a constant factor. The solidthreaded cover may be removed to facilitate drainage. The secondary grate preventsdebris from entering the waste line.

-2 Satin Finish Bronze-63 Spanner Wrench-80 Perforated Stainless Steel Basket-J Backwater Valve

Available Options

APPLICATIONFor use in any non-traffic area. May be attached to any grate to contain condensatewaste, such as under commercial kitchen equipment. May be removed to permitmovement of equipment or pedestrian traffic.

APPLICATIONFor use in any non-traffic area. May be attached to any grate to contain condensatewaste from more than one source or from sources of high volume, such as undercommercial kitchen equipment. May be removed to permit movement of equipmentor pedestrian traffic.

-2 Satin Finish Bronze-92 Galvanized Cast Iron-93 Cast Iron

-2 Satin Finish Bronze-92 Galvanized Cast Iron-93 Cast Iron

Available Options

Available Options

FLOOR DRAINS • Strainer & FunnelsFLOOR DRAINS • Strainer & Funnels

113

FLOO

RD

RAIN

S

TYPE NO. FREE AREA LBS.6F 6.2 6

F8

F9

6 x 3-1/8

4-1/2 x 2-5/8

9 x 3-1/2

4-1/2 x 3-1/2

3-3/4

SECURING HARDWAREFURNISHED BY JOSAM.

SECURING HARDWAREFURNISHED BY JOSAM.

TYPE NO. LBS.

F8 1

F9 4

TYPE NO. A B C LBS.F4 4 3-3/4 2 3F6 6 6 2-5/8 6

F SERIES ROUND NIKALOY STRAINER with Solid Threaded Cover

F4 & F6 SERIES ROUND NIKALOY FUNNEL ASSEMBLIES

F8 & F9 SERIES OVAL NIKALOY FUNNEL ASSEMBLIES

Floor Drains_08.qxd 3/27/08 9:32 AM Page 113

FLOOR DRAINS • StrainersFLOOR DRAINS • Strainers

114

FLO

OR

DRA

INS

APPLICATIONFor use in pedestrian traffic areas where drainage is not a constant factor. Solidhinged cover prevents intrusion of foreign objects, which may be swept up beforecover is opened for wash down. The secondary strainer prevents debris from enteringthe waste line.

APPLICATIONFor use in pedestrian traffic areas where easy accessibility to the drain line throughthe hinged grate is desired.

APPLICATIONFor use as overflow drain in fountains, decorative pools, fishponds or similar areas.Standpipe maintains the prescribed water level and dome prevents floating objectsfrom entering the drain line.

Available Options

Available Options

Available Options

-2 Satin Finish Bronze-J Backwater Valve-VP Secured Grate, Vandal-Proof Screws

-2 Satin Finish Bronze-80 Perforated Stainless Steel Basket, 6H, 7H, 8H-J Backwater Valve-VP Secured Grate, Vandal-Proof Screws

-2 Satin Finish Bronze-24 Less Dome-PF Perforated Standpipe

TYPE NO. A B C D FREE AREA LBS.5H 5 2 1-1/8 4-5/8 6.0 26H 6 2-1/4 1-1/8 5-1/4 7.8 37H 7 2-1/8 1 6-1/2 12.2 48H 8 2-1/2 1 7-1/8 16.1 5

TYPE NO. A B C D LBS.2M 2 2 1-1/8 6 83M 3 1-3/4 1-3/8 6 10

6" HGT. STD.FOR OTHER HGT.,SPECIFY ON ORDER.

TYPE NO. A B C D FREE AREA LBS.5G 5 2 1-1/8 4-5/8 4.1 36G 6 2-1/4 15/16 5-1/4 4.5 47G 7 3-1/4 2 6-1/2 5.7 78G 8 3-1/4 1-1/8 7-1/8 7.8 8

G SERIES ROUND NIKALOY STRAINER with Solid Hinged Cover

H SERIES ROUND NIKALOY STRAINER with Hinged Grate

M SERIES ROUND CHROME PLATED OVERFLOW STANDPIPE with Dome

Floor Drains_08.qxd 3/27/08 9:32 AM Page 114

FLOOR DRAINS • StrainersFLOOR DRAINS • Strainers

115

FLOO

RD

RAIN

S

APPLICATIONFor use in shower rooms or similar areas where the drain can be set at the junctionof the floor and the wall. Vertical grate openings prevent drain stoppage should hori-zontal surface become blocked.

APPLICATIONFor use in shower rooms, gutters and similar areas where a large grate free area isrequired and limited width is available. Suitable for pedestrian traffic.

APPLICATIONFor use in pedestrian traffic areas where square complements construction or floorfinish, such as ceramic tile showers or kitchen floors.

Available Options

Available Options

Available Options

-2 Satin Finish Bronze-80 Perforated Stainless Steel Basket-VP Secured Grate, Vandal-Proof Screws

-2 Satin Finish Bronze-80 Perforated Stainless Steel Basket-J Backwater Valve-VP Secured Grate, Vandal-Proof Screws

-SS Stainless Steel, 5S, 6S, 8S-2 Satin Finish Bronze-80 Perforated Stainless Steel Basket-CP Chrome Plated, 5S, 6S-J Backwater Valve-VP Secured Grate, Vandal-Proof Screws

•Not SUPER-FLO® Design

TYPE NO. A B C D FREE AREA LBS.5S 5 1-3/4 7/8 4-1/2 9.1 36S 6 2-1/8 1 5-5/8 13.8 48S 8 2-3/8 1 7-1/2 24.5 99S• 9 2-3/8 1 8-5/8 28.0 10

TYPE NO. A A1 B C D D1 FREE AREA LBS.5R 9 5 3-1/4 1-1/8 8-3/8 4-3/8 14.9 66R 13 5 3-1/4 1-3/8 12 4 20.0 107R 17 5 3-1/8 1-3/8 16-1/4 4-3/8 22.4 118R 21 5 3-1/8 1-1/4 20-3/8 4-3/8 47.0 13

TYPE NO. A B B1 C FREE AREA LBS.4P 2-1/4 3-1/4 4-1/4 1 8.9 46P 3-1/8 6-1/8 6-1/4 1-1/2 18.7 11

P SERIES ANGLE NIKALOY STRAINER

R SERIES RECTANGULAR NIKALOY STRAINER

S SERIES SUPER-FLO® SQUARE NIKALOY STRAINER

Floor Drains_08.qxd 5/1/08 1:44 PM Page 115

APPLICATIONFor use in pedestrian traffic areas where square complements construction or floorfinish and easy accessibility to the drain line through the hinged grate is desired.

APPLICATIONFor use in extending an adjustable strainer, which must be raised to accommodatedeeper floor fill.

APPLICATIONFor use in pedestrian areas where a composition deck flange is necessary for theadhesion of traffic bearing deck covering.

Available Options

Available Options

-2 Satin Finish Bronze-80 Perforated Stainless Steel Basket for 6T and 9T

-J Backwater Valve-SC Solid Cover, 6T-VP Secured Grate, Vandal-Proof Screws

-2 Satin Finish Bronze-80 Perforated Stainless Steel Basket

-J Backwater Valve-VP Secured Grate, Vandal-Proof Screws

FLOOR DRAINS • StrainersFLOOR DRAINS • Strainers

116

T SERIES SQUARE NIKALOY STRAINER WITH HINGED GRATE

TYPE NO. A B C D FREE AREA LBS.5T 4-7/8 2 7/8 4-3/8 6.5 36T 6 2 3/4 5-5/8 8.3 59T 9 2-3/8 1 8-5/8 28.6 12

TYPE NO. LBS.WF6A 16WF6S 15

W SERIES CAST IRON STRAINER EXTENSION

WF6A & WF6S SERIES NIKALOY STRAINERS FOR COMPOSITION DECKS

FLO

OR

DRA

INS

TYPE NO. B C LBS.2W 2-1/4 3/4 1

Floor Drains_08.qxd 4/24/08 9:09 AM Page 116

APPLICATIONFor use with all adjustable strainers with security screws. The integral trap wall isdesigned to restrict concealment of contraband. The side outlet allows for installationof drain line within pre-cast prison cells.

SPECIFICATIONJOSAM 30000-PD Series galvanized steel security Floor Drain with flashing flange,threaded side outlet, integral trap wall. Threaded to receive any JOSAM adjustablestrainer furnished with security screws.

APPLICATIONFor use with all adjustable strainers. Wide flange anchors drain body in concrete andworks in conjunction with the clamp collar to redirect waste through the collar’sweepholes if seepage occurs around the strainer. The WEJLOC® clamp provides anon-puncturing positive bond of the waterproofing membrane to the drain body forapplications where floors with standing water are to be sealed off from areas below.The collar is also invertible for extra vertical strainer adjustment to meet finishedfloor level.

SPECIFICATIONJOSAM 30000 Series coated cast iron Floor Drain, two-piece body with doubledrainage flange and 1/2” primer tap with plug, bottom outlet, WEJLOC® invertiblenon-puncturing flashing collar with weepholes, threaded to receive a JOSAMadjustable strainer.

t -PD Prison Draint -ST Shallow Trapt -TSO Threaded Side Outlet

-ARE Acid-Resisting Epoxy-49 3/4" Primer Tap

1/2" Primer Tap (Std.)

-91 Rough Bronze Body-92 Galvanized Cast Iron Parts

OUTLETS:-T Threaded Outlet-X Inside Caulk Outlet-Y Hub Outlet with Gasket-Z No-Hub Outlet

-50 1/2" Primer Tap-92 Galvanized Cast Iron Parts-C Bolted Flashing Clamp Device

OUTLET:-T Threaded Outlet

Available Options

Available Options

FLOOR DRAINS • Bodies OnlyFLOOR DRAINS • Bodies Only

117

30000 SERIES BODY ASSEMBLY

30000-PD SERIES SECURITY BODY ASSEMBLY FOR PRISONS

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS.

30002 2 1130003 3 1330004 4 13

FOR OUTLET TYPE SPECIFY -TTYPE NO. PIPE SIZE LBS.30002-PD 2 1530003-PD 3 15

THIS DRAIN BODY CAN BE USED WITH

ALL STRAINERS AND ACCESSORIES

IN THE STRAINER SECTION.

THIS DRAIN BODY CAN BE USED WITH

ALL STRAINERS AND ACCESSORIES

IN THE STRAINER SECTION.

CONFORMS WITH ASTM-C564.

t Product Illustration follows.

FLOO

RD

RAIN

S

Floor Drains_08.qxd 5/1/08 1:48 PM Page 117

APPLICATIONFor use with all adjustable strainers. Wide flange anchors drain body in concrete andworks in conjunction with the clamp collar to redirect waste through the collar’sweepholes if seepage occurs around the strainer. The WEJLOC® clamp provides anon-puncturing positive bond of the waterproofing membrane to the drain body forapplications where floors with standing water are to be sealed off from areas below.Integral threaded side outlet allows for installation in shallow slabs.

SPECIFICATIONJOSAM 30000-TSO Series coated cast iron Floor Drain, two-piece body with doubledrainage flange, integral threaded side outlet, WEJLOC® non-puncturing flashingcollar with weepholes, threaded to receive a JOSAM adjustable strainer.

APPLICATIONFor use with all adjustable strainers. Wide flange anchors drain body in concrete andworks in conjunction with the clamp collar to redirect waste through the collar’sweepholes if seepage occurs around the strainer. The WEJLOC® clamp provides anon-puncturing positive bond of the waterproofing membrane to the drain body forapplications where floors with standing water are to be sealed off from areas below.The collar is also invertible for extra vertical strainer adjustment to meet finishedfloor level in areas such as showers. Low-profile trap provides water seal in shallowfloor slabs.

SPECIFICATIONJOSAM 30002-ST Series coated cast iron Floor Drain, two-piece body with doubledrainage flange and 1/2” primer tap with plug, WEJLOC® invertible non-puncturingflashing collar with weepholes threaded to receive a JOSAM adjustable strainer, bot-tom outlet threaded connection to low profile P trap.

-ARE Acid-Resisting Epoxy-49 3/4" Primer Tap-50 1/2" Primer Tap-92 Galvanized Cast Iron Parts

OUTLET:-TSO Threaded Side Outlet

-ARE Acid-Resisting Epoxy-49 3/4" Primer Tap

1/2" Primer Tap, Std.-92 Galvanized Cast Iron Parts

OUTLETS:-T Threaded Outlet-Z No-Hub Outlet

Available Options

Available Options

FLOOR DRAINS • Bodies OnlyFLOOR DRAINS • Bodies Only

118

FLO

OR

DRA

INS

THIS DRAIN BODY CAN BE USED WITH

ALL STRAINERS AND ACCESSORIES

IN THE STRAINER SECTION.

THIS DRAIN BODY CAN BE USED WITH

ALL STRAINERS AND ACCESSORIES

IN THE STRAINER SECTION.

30000-TSO SERIES BODY ASSEMBLY WITH THREADED SIDE OUTLET

30002-ST SERIES BODY ASSEMBLY WITH SHALLOW TRAP

FOR OUTLET TYPE SPECIFY -T or -ZTYPE NO PIPE SIZE LBS.30002-ST 2 17

TYPE NO. PIPE SIZE A B C D LBS.30002-TSO 2 3 9-1/8 4-5/8 4 1530003-TSO 3 2-1/2 9-1/8 4-5/8 4 1530004-TSO 4 3-1/4 10-1/4 6 4-1/4 15

Floor Drains_08.qxd 4/24/08 9:09 AM Page 118

APPLICATIONFor use with all adjustable strainers in ground-floor installations where clamp deviceis not required.

SPECIFICATIONJOSAM 30304-Z Series coated cast iron body threaded to receive JOSAM adjustablestrainers, no-hub bottom outlet.

APPLICATIONFor use with all adjustable strainers. Wide flange anchors drain body in concrete andworks in conjunction with the clamp to redirect waste through the drain body if seep-age occurs around the strainer. The clamp ring provides a non-puncturing positivebond of the waterproofing membrane to the drain body for applications where floorswith standing water are to be sealed off from areas below. The flush-with-the-floor,integral cleanout allows access to the drain line.

SPECIFICATIONJOSAM 30500 Series coated cast iron combined Floor Drain and integral deep drumtype “P” trap with double drainage flange, no-hub spigot side outlet, weepholes,bronze integral flush-floor cleanout and threaded to receive a JOSAM adjustablestrainer.

-C Bolted Flashing Clamp Device-49 3/4" Primer Tap-50 1/2" Primer Tap-51 1-1/2" Threaded Auxiliary Inlet-52 2" Threaded Auxiliary Inlet-92 Galvanized Cast Iron Parts

OUTLET:-Z No-Hub Outlet

Available Options

FLOOR DRAINS • Bodies OnlyFLOOR DRAINS • Bodies Only

119

FLOO

RD

RAIN

S

THIS DRAIN BODY CAN BE USED WITH

ALL STRAINERS AND ACCESSORIES

IN THE STRAINER SECTION.

THIS DRAIN BODY CAN BE USED WITH

ALL STRAINERS AND ACCESSORIES

IN THE STRAINER SECTION.

30304-Z SERIES CAST IRON BODY

30500 SERIES BODY WITH TRAP FLUSH-WITH-FLOOR CLEANOUT

* IPS PRIMER TAPPING (-49) & (-50)AUX. THREADED INLET (-51) & (-52)

FOR OUTLET TYPE SPECIFY -ZTYPE NO. PIPE SIZE LBS.30304-Z 4 3

FOR OUTLET TYPE SPECIFY -ZTYPE NO. PIPE SIZE J* LBS.

30502 2 3 2730503 3 3-1/2 2730504 4 4-1/8 29

Floor Drains_08.qxd 3/27/08 9:32 AM Page 119

FLOOR DRAINS • Body/Strainer CombinationsFLOOR DRAINS • Body/Strainer Combinations

120

FLO

OR

DRA

INS

30000-A SERIES 30000-C SERIESBody with Round SUPER-FLO® Strainer

Body with Dome Strainer

TYPENO.

PIPESIZE

TYPENO. B

ADJUSTABLE STRAINERADJUSTMENT FREE

AREA LBS.†X Y30002 2 5A 5 3/4 2-1/8 7.8 1430003 3 6A 6 1-1/4 2-3/8 11.0 1530004 4 7A 7 1-1/8 2-7/8 13.2 16

† STRAINER W/BODY 8A 8 1-5/8 2-5/8 16.2 17

CONFORMS WITH ASTM-C564.

CONFORMS WITH ASTM-C564.

CONFORMS WITH ASTM-C564.

CONFORMS WITH ASTM-C564.

Body with Non-Clog Strainer & Bucket

30000-D SERIES 30000-E SERIES Body with Tractor Strainer

TYPENO.

PIPESIZE

TYPENO.

ADJUSTABLE STRAINERADJUSTMENT FREE

AREA LBS.†X Y30002 2 5C 3/4 1-7/8 4.5 1530003 330004 4

† STRAINER W/BODY

TYPENO.

PIPESIZE

TYPENO. B

ADJUSTABLE STRAINERADJUSTMENT FREE

AREA LBS.†X Y30002 2 6E 6 2-1/4 3-1/2 6.7 1730003 3 7E 7 1-7/8 3-1/8 12.0 1830004 4 9E 9 2-1/4 3-3/8 21.2 23

† STRAINER W/BODY

TYPENO.

PIPESIZE

TYPENO. A B

ADJUSTABLE STRAINERADJUSTMENT FREE

AREA LBS.†X Y30002 2 5D 5 1-7/8 3/4 2-1/8 8.1 1530003 3 6D 6 1-3/4 1-1/4 2-3/8 8.1 1630004 4

† STRAINER W/BODY

Floor Drains_08.qxd 5/1/08 1:53 PM Page 120

FLOOR DRAINS • Body/Strainer CombinationsFLOOR DRAINS • Body/Strainer Combinations

121

FLOO

RD

RAIN

S

30000-E1 SERIESBody with Extended Rim Strainer

CONFORMS WITH ASTM-C564.

30000-E2 SERIESBody with Strainer with Round Funnel

CONFORMS WITH ASTM-C564.

30000-P SERIESBody with Angle Strainer

CONFORMS WITH ASTM-C564.

30000-R SERIESBody with Rectangular Strainer

TYPENO.

PIPESIZE

ADJUSTABLE STRAINER

LBS.†TYPENO.

ADJUSTMENT FREEAREABxB’ X Y

30002 2 5R 5x9 1-7/8 3-1/4 14.9 1830003 3 6R 5x13 1-3/4 3-1/4 20.0 2230004 4 7R 5x17 1-7/8 3-1/4 22.4 23

† STRAINER W/BODY 8R 5x21 1-7/8 3-1/4 47.0 25

CONFORMS WITH ASTM-C564.

TYPENO.

PIPESIZE

ADJUSTABLE STRAINER

LBS.†TYPENO.

ADJUSTMENT FREEAREABxB’ X Y Z

30002 2 4P 3-1/4x4-1/4 7/8 1-3/4 1-3/4 8.9 1630003 3 6P 6-1/8x6-1/4 1-5/8 3-7/8 3-1/8 18.7 2330004 4

† STRAINER W/BODY

TYPENO.

PIPESIZE

TYPENO. B

ADJUSTABLE STRAINERADJUSTMENT FREE

AREA LBS.†X Y30002 2 6E1 6 2-1/4 3-1/2 4 1630003 3 7E1 7 1-7/8 3-1/8 8.2 1730004 4 9E1 9 2-1/4 3-3/8 21.2 20

† STRAINER W/BODY

TYPENO.

PIPESIZE

TYPENO. B

ADJUSTABLE STRAINERADJUSTMENT FREE

AREA LBS.†X Y30002 2 7E2 7 1 2-5/8 7.5 2030003 330004 4

† STRAINER W/BODY

Floor Drains_08.qxd 4/24/08 9:09 AM Page 121

FLOOR DRAINS • Body/Strainer CombinationsFLOOR DRAINS • Body/Strainer Combinations

122

30000-S SERIES

30304-Z-A SERIES 30500-A SERIES

Body with Square SUPER-FLO® Strainer

Body with Round SUPER-FLO® Strainer

Body with Shallow Trap & Round SUPER-FLO® Strainer

Body with Cleanout & Round SUPER-FLO® Strainer

TYPENO.

PIPESIZE

ADJUSTABLE STRAINER

LBS.†TYPENO.

ADJUSTMENTAREAB X Y

30002 2 5S 5 7/8 1-7/8 9.1 1530003 3 6S 6 7/8 2-1/4 13.8 1630004 4 8S 8 1-1/4 2-1/2 24.5 21† STRAINER W/BODY

CONFORMS WITH ASTM-C564.

* IPS PRIMER TAPPING (-49) & (-50)AUX. THREADED INLET (-51) & (-52)

30002-ST-A SERIES

TYPENO.

PIPESIZE

ADJUSTABLE STRAINER

LBS.†TYPENO.

ADJUSTMENT FREEAREATOP SIZE X Y

30304-Z 4 5A 5 3/4 2-1/8 7.8 56A 6 1-1/4 2-3/8 11.0 67A 7 1-1/8 2-7/8 13.2 7

† STRAINER W/BODY 8A 8 1-5/8 2-5/8 16.2 8

TYPENO.

PIPESIZE J*

ADJUSTABLE STRAINER

LBS.†TYPENO.

ADJUSTMENTAREAB X Y

30502 2 3 5A 5 1-3/8 2-1/8 7.8 3030503 3 3-1/2 6A 6 1-5/8 2-3/8 11.0 3130504 4 4-1/8 7A 7 1-5/8 2-3/8 13.2 32

† STRAINER W/BODY 8A 8 2 2-5/8 16.2 33

TYPENO.

PIPESIZE

TYPENO.

ADIA.

ADJUSTABLE STRAINERADJUSTMENT FREE

AREA LBS.†X Y30002-ST-A 2 5A 5 3/4 2-1/8 7.8 19

6A 6 1-1/4 2-3/8 11.0 207A 7 1-1/8 2-7/8 13.2 21

†STRAINER W/BODY 8A 8 1-5/8 2-5/8 16.2 22

FLO

OR

DRA

INS

Floor Drains_08.qxd 3/27/08 9:32 AM Page 122

APPLICATIONFor use in areas where the waterproofing is installed at the finish floor level andpedestrian traffic is expected. Wide flange anchors drain body in concrete and worksin conjunction with the clamp collar to redirect waste through the collar’s weepholesif seepage occurs around the strainer. The WEJLOC® clamp provides a non-puncturingpositive bond of the waterproofing membrane to the drain body for applicationswhere floors with standing water are to be sealed off from areas below.

SPECIFICATIONJOSAM 30900-9AD Series coated cast iron Floor Drain with double drainage flange,weepholes, bottom outlet and satin Nikaloy round strainer in an adjustable Nikaloyclamping collar which secures flashing or waterproofing at finished floor.

APPLICATIONFor use in finished areas with pedestrian traffic such as toilet and shower rooms. Wideflange anchors drain body in concrete and work in conjunction with the clamp collarto redirect waste through the collar’s weepholes if seepage occurs around the strainer.collar is also invertible for extra vertical strainer adjustment tomeet finished floor level.

SPECIFICATIONJosam 30802-4CP Series coated cast iron Floor Drain, two-piece body with invertible clampcollar, weepholes, 2” low-profile trap and 4” round adjustable chrome-plated strainer.

-SQ Square Top-LT Less Shallow Trap

OUTLETS:-T Threaded Outlet-Z No-Hub Outlet

Available Options

Available Options-2 Satin Finish Bronze-92 Galvanized Cast Iron Parts-VP Secured Grate, Vandal-Proof

Screws

OUTLETS:-66 No-Hub Side Outlet-T Threaded Outlet-X Inside Caulk Outlet-Y Hub Outlet with Gasket-Z No-Hub Outlet

APPLICATIONWide flange anchors drain body in concrete with 5” round adjustable Nikaloy top forfinished floors subject to pedestrian traffic.

SPECIFICATIONJOSAM 31000 Series coated cast iron Floor Drain, double drainage flange and 1/2”primer tap with plug, bottom outlet and 5" round adjustable Nikaloy top.

Available Options-C Bolted Flashing Clamp Device-SQ Square Top

OUTLETS:-Y Hub Outlet with Gasket, 2”, 3”-Z No-Hub Outlet, 3”, 4”

FLOOR DRAINS • Body/Strainer AssembliesFLOOR DRAINS • Body/Strainer Assemblies

123

30802-4CP SERIES CAST IRON BODY & TRAP ASSEMBLY WITH ADJ. STRAINERAPPLICATION

For use in finished areas with pedestrian traffic such as toilet and shower rooms.Wide flange anchors drain body in concrete and works in conjunction with the clampcollar to redirect waste through the collar’s weepholes if seepage occurs around thestrainer. Collar is also invertible for extra vertical strainer adjustment to meet finishedfloor level.

SPECIFICATIONJOSAM 30802-4CP Series coated cast iron Floor Drain, two-piece body with invertibleclamp collar, weepholes, 2” low-profile trap and 4” round adjustable chrome-platedstrainer.

-SQ Square Top-LT Less Shallow Trap

OUTLETS:-T Threaded Outlet-Z No-Hub Outlet

Available Options

30802-4CP SERIES CAST IRON BODY & TRAP ASSEMBLY WITH ADJ. STRAINER

30900-9AD SERIES BODY WITH STRAINER WITH CLAMP DEVICE

31000 SERIES BODY WITH 5” ROUND NIKALOY TOP

FOR OUTLET TYPE, SPECIFY -T or -Z

TYPENO.

PIPESIZE

STRAINERADJUSTMENT FREE

AREA LBS.X Y

30802-4CP 2 1 2-1/8 3.8 8

FOR OUTLET TYPE, SPECIFY -T, -X, -Y or -Z

TYPENO.

PIPESIZE

STRAINERADJUSTMENT FREE

AREA LBS.†X Y

30902-9AD 2 1-1/8 2-5/8 16.5 3330903-9AD 3

†STRAINER WITH BODY30904-9AD 4

CONFORMS WITH ASTM-C564.

FOR OUTLET TYPE, SPECIFY -Y or Z

TYPENO.

PIPESIZE

TOPSIZE

STRAINERADJUSTMENT LBS.

MIN MAX31002 2 5 3/4 2-1/8 931003 3 5 3/4 2-1/8 931004 4 5 3/4 2-1/8 9

FLOO

RD

RAIN

S

Floor Drains_08.qxd 5/1/08 1:44 PM Page 123

FLOOR DRAINS • Round TopsFLOOR DRAINS • Round Tops

124

FLO

OR

DRA

INS

APPLICATIONFor use in moderate traffic areas such as automobile garages for any type of floorconstruction where a small to medium flow of liquid is anticipated.

SPECIFICATIONJOSAM 32100 Series coated cast iron Floor Drain, two-piece body with doubledrainage flange, WEJLOC® non-puncturing flashing collar, weepholes, bottom outlet,round top, medium-duty loose-set anti-tilting SUPER-FLO® grate with perimeterdrainage slots.

Available Options

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.CONFORMS WITH ASTM-C564.

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS.

32102 2 1832103 3 2132104 4 21

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS.32102-39 2 2232103-39 3 2532104-39 4 25

32100 SERIES SUPER-FLO® 9" TOP

32100-39 SERIES with -39 Solid Cast Iron CoverAPPLICATION

For use in unfinished floors subject to medium-duty traffic where access to drain out-let is limited by removable solid cover. Useful in regulating small solids into drain line.

SPECIFICATIONJOSAM 32100-39 Series coated cast iron Floor Drain with double drainage flange,weepholes, bottom outlet and 9" round solid scoriated cast iron cover.

OPTIONS N/A:-81, -84

32100 SLOT WIDTH 3/8"32100-1 SLOT WIDTH 3/16"32100-2 SLOT WIDTH 3/16"

t -AE LEVELEZE® Adjustable Extensiont -81 Slotted Cast Iron Buckett -TG Tractor Gratet -LC1 Locking Cover, Satin Finish

Nikaloy-LC2 Locking Cover, Satin Finish

Bronze-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-7 Ductile Iron Grate-11 Extra-Heavy Grate, Cast Iron-13 Dome Grate, Cast Iron-13-1 Dome Grate, Nikaloy-13-2 Dome Grate, Bronze-15 Chained Grate

t -39 Solid Cast Iron Cover-VP Secured Grate,

Vandal-Proof Screws

-ARE Acid-Resisting Epoxy-44 Fixed Extension Collar, Cast

Iron (Specify Hgt.), 3" Std.-44-92 Fixed Extension Collar, Galv.

(Specify Hgt.), 3" Std.-49 3/4" Primer Tap-50 1/2" Primer Tap-84 Stainless Steel Mesh

Bucket Liner-88 Supplementary Strainer-92 Galvanized Cast Iron Parts

OUTLETS:-66 No-Hub Side Outlet-T Threaded Outlet-X Inside Caulk Outlet-Y Hub Outlet with Gasket-Z No-Hub Outlet

t Product Illustration follows.

CONFORMS WITH ASTM-C564.

Floor Drains_08.qxd 3/27/08 9:32 AM Page 124

FLOOR DRAINS • Round TopsFLOOR DRAINS • Round Tops

125

FLOO

RD

RAIN

S

32100-81 SERIES with -81 Slotted Cast Iron Bucket

32100-AE SERIES with -AE LEVELEZE® Extension

32100-AE-81 SERIES with -AE LEVELEZE® Extension & -81 Slotted Cast Iron Bucket

APPLICATIONFor use in medium traffic areas, such as commercial auto garages, for any type offloor construction where a medium to large flow of liquid is anticipated and a bucketis necessary to collect debris which may clog the waste line.

SPECIFICATIONJOSAM 32100-81 Series coated cast iron Floor Drain, two-piece body with doubledrainage flange, WEJLOC® non-puncturing flashing collar, weepholes, bottom outlet,round top, and removable sediment bucket which supports a medium-duty loose-setanti-tilting SUPER-FLO® grate with perimeter drainage slots.

OPTIONS N/A:-11, -13, -13-1, -13-2, -39-LC1, -LC2

APPLICATIONFor use in moderate traffic areas, such as automobile garages, for any type of floorconstruction where a small to medium flow of liquid is anticipated. LEVELEZE®

adjustable collar permits accurate positioning of grate to meet finished floor level.

SPECIFICATIONJOSAM 32100-AE Series coated cast iron LEVELEZE® Floor Drain, two-piece bodywith double drainage flange, WEJLOC® non-puncturing flashing collar, weepholes,bottom outlet, round top, adjustable collar with rolled thread and loose-set, anti-tilting, medium-duty, SUPER-FLO® grate with perimeter drainage slots.

OPTION N/A:-11, -44

APPLICATIONFor use in moderate traffic areas, such as commercial auto garages, for any type offloor construction where a small to medium flow of liquid is anticipated and a bucketis necessary to collect debris which may clog the waste line. LEVELEZE® adjustablecollar permits accurate positioning of grate to meet finished floor level.

SPECIFICATIONJOSAM 32100-AE-81 Series coated cast iron LEVELEZE® Floor Drain, two-piece body withdouble drainage flange,WEJLOC® non-puncturing flashing collar, weepholes, bottom outlet,round top, adjustable collar with rolled thread and removable sediment bucket which sup-ports a medium-duty, loose-set, anti-tilting, SUPER-FLO® grate with perimeter drainage slots.

OPTIONS N/A:-11, -13, -13-1, -13-2, -39, -44

32100-81 SLOT WIDTH 1/2"32100-81-1 SLOT WIDTH 3/16"32100-81-2 SLOT WIDTH 3/16"

32100-AE SLOT WIDTH 3/8"32100-AE-1 SLOT WIDTH 3/16"32100-AE-2 SLOT WIDTH 3/16"

32100-AE-81 SLOT WIDTH 3/8"32100-AE-81-1 SLOT WIDTH 3/16"32100-AE-81-2 SLOT WIDTH 3/16"

CONFORMS WITH ASTM-C564.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

CONFORMS WITH ASTM-C564.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

CONFORMS WITH ASTM-C564.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

TYPE NO. PIPE SIZE LBS.30002-81 2 2230003-81 3 2430004-81 4 25

TYPE NO. PIPE SIZE LBS.30002-AE 2 3130003-AE 3 3230004-AE 4 33

TYPE NO. PIPE SIZE LBS.30002-AE-81 2 3430003-AE-81 3 3430004-AE-81 4 34

FOR OUTLET TYPE, SPECIFY -T, -X, -Y or -Z.

FOR OUTLET TYPE, SPECIFY -T, -X, -Y or -Z.

FOR OUTLET TYPE, SPECIFY -T, -X, -Y or -Z.

Floor Drains_08.qxd 5/1/08 1:44 PM Page 125

FLOOR DRAINS • Round TopsFLOOR DRAINS • Round Tops

126

FLO

OR

DRA

INS

32100-AE-LC1-88 SERIES w/ LEVELEZE® Ext., Nikaloy Locking Cover & Supl. Strainer

32100-AE-TG SERIES with -AE LEVELEZE® Extension & -TG 9" Tractor Top

32100-TG SERIES with -TG 9" Tractor Top

CONFORMS WITH ASTM-C564.

CONFORMS WITH ASTM-C564.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

CONFORMS WITH ASTM-C564.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

FOR OUTLET TYPE, SPECIFY -T, -X, -Y or -Z.

FOR OUTLET TYPE, SPECIFY -T, -X, -Y or -Z.

FOR OUTLET TYPE, SPECIFY -T, -X, -Y or -Z.

APPLICATIONFor use in pedestrian and light wheel traffic areas where drainage is not a constantfactor. Solid hinged key-locking cover prevents intrusion of foreign objects, whichmay be swept up before cover is opened for wash down. The secondary strainer pre-vents debris from entering the waste line.

SPECIFICATIONJOSAM 32100-AE-LC1-88 Series coated cast iron LEVELEZE® Floor Drain, two-piecebody with double drainage flange, WEJLOC® non-puncturing flashing collar, weep-holes, bottom outlet, round satin Nikaloy hinged key-locking cover, adjustable collarand internal strainer.

Series 32100-AE-LC2-88 with Bronze Locking Cover

OPTIONS N/A:-7, -11, -13, -13-1, -13-2, -15, -39, -44, -84

APPLICATIONFor use in heavy traffic areas, such as warehouses, for any type of floor constructionwhere a small to medium flow of liquid is anticipated. LEVELEZE® adjustable collarpermits accurate positioning of grate to meet finished floor level.

SPECIFICATIONJOSAM 32100-AE-TG Series coated cast iron LEVELEZE® Floor Drain, two-piece bodywith double drainage flange, WEJLOC® non-puncturing flashing collar, weepholes,bottom outlet, round top, adjustable collar with rolled thread and heavy-duty, deep-set tractor grate.

OPTIONS N/A:-11, -13, -13-1, -13-2, -39, -44,-81, -84

APPLICATIONFor use in heavy traffic areas such as garages and loading docks for any type of floorconstruction where a small to medium flow of liquid is anticipated.

SPECIFICATIONJOSAM 32100-TG Series coated cast iron Floor Drain, two-piece body with doubledrainage flange, WEJLOC® non-puncturing flashing collar, weepholes, bottom outlet,round top and heavy-duty, loose-set tractor grate.

OPTIONS N/A:-11, -13, -13-1, -13-2, -39, -81, -84,

TYPE NO. PIPE SIZE LBS.32102-AE-LC1-88 2 3132103-AE-LC1-88 3 3232104-AE-LC1-88 4 33

TYPE NO. PIPE SIZE LBS.32102-AE-TG 2 3332103-AE-TG 3 3532104-AE-TG 4 37

TYPE NO. PIPE SIZE LBS.32102-TG 2 2532103-TG 3 2632104-TG 4 27

32100-AE-TG SLOT WIDTH 1/2"32100-AE-TG-1 SLOT WIDTH 7/16"32100-AE-TG-2 SLOT WIDTH 7/16"

SLOT WIDTH 3/8"

Floor Drains_08.qxd 5/1/08 1:45 PM Page 126

FLOOR DRAINS • Round TopsFLOOR DRAINS • Round Tops

127

FLOO

RD

RAIN

S

APPLICATIONFor use in heavy traffic areas such as packinghouse kill floors. One drain body isconnected to the waste line and the other to the blood tank. During slaughtering,the SUPER-FLO® grate is placed in the drain connected to the blood tank and thewaste line is plugged with the solid cover. The grate and cover are interchangedduring wash down and clean up.

SPECIFICATIONJOSAM 32150 Series coated cast iron Floor Drains with double drainage flanges,weepholes, bottom outlets, 9" round tops, one body furnished with a solid bronzeplug, the other body furnished with an extra heavy-duty, anti-tilting, SUPER-FLO®

grate with perimeter drainage slots.

APPLICATIONFor use in heavy traffic areas such as garages and loading docks for any type of floorconstruction where a small to medium flow of liquid is anticipated. Deep drain bodyhas provisions for side auxiliary inlets, which can be used to receive the waste fromother fixtures or drains. The body will also accept a flapper type backwater valve foruse in areas subject to backflow conditions.

SPECIFICATIONJOSAM 32160 Series coated cast iron Floor Drain with double drainage flange,weepholes, bottom outlet, inside caulk connection, round top and heavy-duty,loose-set, tractor grate.

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS.

32152 2 3832153 3 4132154 4 43

FOR OUTLET TYPE SPECIFY -XTYPE NO. PIPE SIZE F LBS.

32163 3 10-7/8 4832164 4 11-1/4 48

-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-7 Ductile Iron Grate-44 Fixed Extension Collar, Cast

Iron (Specify Hgt.), 3" Std.-44-92 Fixed Extension Collar, Galv.

(Specify Hgt.), 3" Std.-92 Galvanized Cast Iron Parts-ARE Acid-Resisting Epoxy

OUTLETS:-T Threaded Outlet-X Inside Caulk Outlet-Y Hub Outlet with Gasket-Z No-Hub Outlet

-7 Ductile Iron Grate-12 Square Top, Cast Iron-15 Chained Grate-19 C. I. Undergrate with

Satin Finish Nikaloy Top-20 C. I. Undergrate with

Satin Finish Bronze Top-44 Fixed Ext. Collar, CI,

(Specify Hgt.), 3" Std.-49 3/4" Primer Tap-50 1/2" Primer Tap-51 1-1/2" Auxiliary

Threaded Inlet-52 2" Auxiliary Threaded Inlet-53 2" Auxiliary Hub Inlet-54 2" Auxiliary Spigot Inlet

-53-92 2" Auxiliary Hub Inlet, Galv.-54-92 2" Auxiliary Spigot Inlet,

Galvanized-60 Backwater Valve

s -62 “T” Handle Bronze Closure Plug

s -71 Solid Cast Iron Buckets -81 Slotted Cast Iron Buckets -88 Supplementary Strainer

-92 Galvanized Cast Iron Parts-ARE Acid-Resisting Epoxy-VP Secured Grate,

Vandal-Proof ScrewsOUTLETS:

-66 No-Hub Side Outlet-X Inside Caulk Outlet

CONFORMS WITH ASTM-C564.

ss WEIGHT INCLUDES BOTH DRAINS.

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

32160 SERIES DEEP BODY, 9" TRACTOR TOP

32150 SERIES SUPER-FLO® 9" BLOOD DRAIN

Available Options

Available Options

s Cannot be installed when Backwater Valve is ordered.

SLOT WIDTH 3/8"

Floor Drains_08.qxd 4/24/08 9:09 AM Page 127

FLOOR DRAINS • Round TopsFLOOR DRAINS • Round Tops

128

FLO

OR

DRA

INS

32200 SERIES SHALLOW SUMP, SUPER-FLO® 12" TOP

32200-81 SERIES with -81 Slotted Cast Iron Bucket

APPLICATIONFor use in medium traffic areas, such as car washes, for any type of floor constructionwhere a medium to heavy flow of liquid is anticipated.

SPECIFICATIONJOSAM 32200 Series coated cast iron Floor Drain, shallow two-piece body with doubledrainage flange, WEJLOC® non-puncturing flashing clamp collar, weepholes, bottomoutlet, round top, and medium-duty loose-set anti-tilting SUPER-FLO® grate withperimeter drainage slots.

t -AE LEVELEZE® Adjustable Ext.t -81 Slotted Cast Iron Buckett -SD Special-Duty Grate

-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-4 Secondary Flashing Clamp

(use with -AE only)-7 Ductile Iron Grate-13 Dome Grate, Cast Iron-13-1 Dome Grate, Nikaloy-13-2 Dome Grate, Bronze-15 Chained Grate-ARE Acid-Resisting Epoxy-VP Secured Grate,

Vandal-Proof Screws-44 Fixed Extension Collar, C.I.

(Specify Hgt.), 2" Std.

-44-92 Fixed Extension Collar, Galv.(Specify Hgt.), 2" Std.

-49 3/4" Primer Tap-50 1/2" Primer Tap-84 Stainless Steel Mesh Bucket

Liner-88 Supplementary Strainer-92 Galvanized Cast Iron Parts

OUTLETS:-66 No-Hub Side Outlet, 2"- 6"-T Threaded Outlet-X Inside Caulk Outlet-Y Hub Outlet with Gasket,

2"- 4"-Z No-Hub Outlet

Available Options

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.32202 2 48 32205 5 5032203 3 48 32206 6 4932204 4 48 32208 8 46

32200 SLOT WIDTH 9/16"32200-1 SLOT WIDTH 7/16"32200-2 SLOT WIDTH 7/16"

CONFORMS WITH ASTM-C564.THIS DIM. IS 5-3/4" FOR 32208-T.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

APPLICATIONFor use in medium traffic areas, such as car washes, for any type of floor constructionwhere a medium to large flow of liquid is anticipated and a bucket is necessary tocollect debris which may clog the waste line.

SPECIFICATIONJOSAM 32200-81 Series coated cast iron Floor Drain, shallow two-piece body withdouble drainage flange, WEJLOC® non-puncturing flashing clamp collar, weepholes,bottom outlet, round top and removable sediment bucket which supports a medium-duty loose-set anti-tilting SUPER-FLO® grate with perimeter drainage slots.

OPTION N/A:-4

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.32202-81 2 53 32205-81 5 5532203-81 3 53 32206-81 6 5432204-81 4 53 32208-81 8 51

32200-81 SLOT WIDTH 9/16"32200-81-1 SLOT WIDTH 1/2"32200-81-2 SLOT WIDTH 1/2"

CONFORMS WITH ASTM-C564.THIS DIM. IS 5-3/4" FOR 32208-81-T.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

t Product Illustration follows.

Floor Drains_08.qxd 4/24/08 9:09 AM Page 128

FLOOR DRAINS • Round TopsFLOOR DRAINS • Round Tops

129

FLOO

R DRA

INS

32200-AE SERIES with -AE LEVELEZE® Extension

32200-AE-81 SERIES with -AE LEVELEZE® Ext. & -81 Slotted Cast Iron Bucket

APPLICATIONFor use in medium traffic areas for any type of floor construction where a medium to heavy flow of liquid is anticipated, such as a car or truck wash. LEVELEZE®

adjustable collar permits accurate positioning of grate to meet finished floor level.

SPECIFICATIONJOSAM 32200-AE Series coated cast iron LEVELEZE® Floor Drain with round top, gratesupport collar with double drainage flange and weepholes, bottom outlet, adjustablecollar, bolted support ring, large sump body, and medium-duty, loose-set, anti-tilting,SUPER-FLO® grate with perimeter drainage slots.

OPTION N/A:-84

APPLICATIONFor use in medium traffic areas for any type of floor construction where a medium tolarge flow of liquid is anticipated and a bucket is necessary to collect debris whichmay clog the waste line, such as a car or truck wash. LEVELEZE® adjustable collarpermits accurate positioning of grate to meet finished floor level.

SPECIFICATIONJOSAM 32200-AE-81 Series coated cast iron LEVELEZE® Floor Drain with round top,grate support collar with double drainage flange and weepholes, bottom outlet,adjustable collar, bolted support ring, large sump body, and removable sedimentbucket which supports a medium-duty, loose-set, anti-tilting, SUPER-FLO® grate withperimeter drainage slots.

32200-AE SLOT WIDTH 9/16"32200-AE-1 SLOT WIDTH 7/16"32200-AE-2 SLOT WIDTH 7/16"

32200-AE-81 SLOT WIDTH 9/16"32200-AE-81-1 SLOT WIDTH 7/16"32200-AE-81-2 SLOT WIDTH 7/16"

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.32202-AE 2 74 32205-AE 5 7632203-AE 3 74 32206-AE 6 7532204-AE 4 74 32208-AE 8 72

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.32202-AE-81 2 80 32205-AE-81 5 8232203-AE-81 3 80 32206-AE-81 6 8132204-AE-81 4 80 32208-AE-81 8 78

CONFORMS WITH ASTM-C564.THIS DIM. IS 5-3/4" FOR 32208-AE-T.

s WITH -4 SECONDARY FLASHING CLAMP 2-1/4” MIN. 4-1/4” MAX.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

CONFORMS WITH ASTM-C564.THIS DIM. IS 5-3/4" FOR 32208-AE-81-T.

s WITH -4 SECONDARY FLASHING CLAMP 2-1/4” MIN. 4-1/4” MAX.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

Floor Drains_08.qxd 3/27/08 9:32 AM Page 129

FLOOR DRAINS • Round TopsFLOOR DRAINS • Round Tops

130

FLO

OR

DRA

INS

32200-AE-SD SERIES with -AE LEVELEZE® Ext. & -SD Special-Duty Grate

32200-SD SERIES with -SD Special-Duty Grate

APPLICATIONFor use in extra heavy traffic areas such as industrial plants and warehouses withheavy forklifts, for any type of floor construction where a medium to large flow ofliquid is anticipated. LEVELEZE® adjustable collar permits accurate positioning ofgrate to meet finished floor level.

SPECIFICATIONJOSAM 32200-AE-SD Series coated cast iron LEVELEZE® Floor Drain with round top,grate support collar with double drainage flange and weepholes, adjustable collar,bolted support ring, large sump body, bottom outlet and loose-set, special-duty grate.

OPTIONS N/A:-7, -13, -13-1, -13-2

APPLICATIONFor use in extra heavy traffic areas such as military vehicle garages and loading docksfor any type of floor construction where a medium flow of liquid is anticipated.

SPECIFICATIONJOSAM 32200-SD Series coated cast iron Floor Drain, shallow two-piece body withdouble drainage flange, WEJLOC® non-puncturing flashing clamp collar, weepholes,bottom outlet, round top and special-duty, loose-set grate.

OPTIONS N/A:-4, -7, -13, -13-1, -13-2

32200-AE-SD SLOT WIDTH 1/2"32200-AE-SD-1 SLOT WIDTH 1/4"32200-AE-SD-2 SLOT WIDTH 1/4"

32200-SD SLOT WIDTH 1/2"32200-SD-1 SLOT WIDTH 1/4"32200-SD-2 SLOT WIDTH 1/4"

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.32202-AE-SD 2 87 32205-AE-SD 5 8932203-AE-SD 3 87 32206-AE-SD 6 8832204-AE-SD 4 87 32208-AE-SD 8 85

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.32202-SD 2 61 32205-SD 5 6332203-SD 3 61 32206-SD 6 6232204-SD 4 61 32208-SD 8 59

CONFORMS WITH ASTM-C564.THIS DIM. IS 5-3/4" FOR 32208-SD-T.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

CONFORMS WITH ASTM-C564.THIS DIM. IS 5-3/4" FOR 32208-AE-SD-T.

s WITH -4 SECONDARY FLASHING CLAMP 2-1/4” MIN. 4-1/4” MAX.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

Floor Drains_08.qxd 3/27/08 9:32 AM Page 130

FLOOR DRAINS • Round TopsFLOOR DRAINS • Round Tops

131

FLOO

R DRA

INS

32300 SERIES MEDIUM SUMP, SUPER-FLO® 12" TOP

32300-81 SERIES with -81 Slotted Cast Iron BucketAPPLICATION

For use in medium traffic areas, such as truck washes, for any type of floor construc-tion where a medium to large flow of liquid is anticipated and a bucket is necessaryto collect debris which may clog the waste line.

SPECIFICATIONJOSAM 32300-81 Series coated cast iron Floor Drain, medium-deep two-piece bodywith double drainage flange, WEJLOC® non-puncturing flashing clamp collar, weep-holes, bottom outlet, round top and removable sediment bucket which supports amedium-duty loose-set anti-tilting SUPER-FLO® grate with perimeter drainage slots.

t -81 Slotted Cast Iron Bucket-SD Special Duty Grate-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-7 Ductile Iron Grate-13 Dome Grate, Cast Iron-13-1 Dome Grate, Nikaloy-13-2 Dome Grate, Bronze-15 Chained Grate-ARE Acid-Resisting Epoxy-VP Secured Grate,

Vandal-Proof Screws-44 Fixed Extension Collar, Cast

Iron (Specify Hgt.) 2" Std.

-44-92 Fixed Extension Collar, Galv.(Specify Hgt.) 2" Std.

-49 3/4" Primer Tap-50 1/2" Primer Tap-84 Stainless Steel Mesh

Bucket Liner-88 Supplementary Strainer-92 Galvanized Cast Iron Parts

OUTLETS:-66 No-Hub Side Outlet, 2"- 6"-X Inside Caulk Outlet-Z No-Hub Outlet ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

FOR OUTLET TYPE SPECIFY -X or -ZTYPE NO. PIPE SIZE FREE AREA LBS. TYPE NO. PIPE SIZE FREE AREA LBS.32302 2 59 58 32305 5 59 6132303 3 59 59 32306 6 59 6232304 4 59 60 32308 8 59 64

FOR OUTLET TYPE SPECIFY -X or -ZTYPE NO. PIPE SIZE FREE AREA LBS. TYPE NO. PIPE SIZE FREE AREA LBS.32302-81 2 43.5 69 32305-81 5 43.5 7232303-81 3 43.5 70 32306-81 6 43.5 7332304-81 4 43.5 71 32308-81 8 43.5 75

APPLICATIONFor use in medium traffic areas, such as truck washes, for any type of floor construc-tion where a medium to heavy flow of liquid is anticipated. The deeper sump ensuresrapid drainage.

SPECIFICATIONJOSAM 32300 Series coated cast iron Floor Drain, medium-deep two-piece body withdouble drainage flange, WEJLOC® non-puncturing flashing clamp collar, weepholes,bottom outlet, round top and medium-duty loose-set anti-tilting SUPER-FLO® gratewith perimeter drainage slots.

32300-81 SLOT WIDTH 9/16"32300-81-1 SLOT WIDTH 1/2"32300-81-2 SLOT WIDTH 1/2"

32300 SLOT WIDTH 9/16"32300-1 SLOT WIDTH 7/16"32300-2 SLOT WIDTH 7/16"

t -81 Slotted Cast Iron Bucket-SD Special-Duty Grate-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-7 Ductile Iron Grate-13 Dome Grate, Cast Iron-13-1 Dome Grate, Nikaloy-13-2 Dome Grate, Bronze-15 Chained Grate-ARE Acid-Resisting Epoxy-VP Secured Grate,

Vandal-Proof Screws-44 Fixed Extension Collar, Cast

Iron (Specify Hgt.), 2" Std.

-44-92 Fixed Extension Collar, Galv.(Specify Hgt.), 2" Std.

-49 3/4" Primer Tap-50 1/2" Primer Tap-84 Stainless Steel Mesh

Bucket Liner-88 Supplementary Strainer-92 Galvanized Cast Iron Parts

OUTLETS:-66 No-Hub Side Outlet, 2"- 6"-X Inside Caulk Outlet-Z No-Hub Outlet

Available Options

t Product Illustration follows.

Floor Drains_08.qxd 3/27/08 9:32 AM Page 131

FLOOR DRAINS • Round TopsFLOOR DRAINS • Round Tops

132

FLO

OR

DRA

INS

32330 SERIES DEEP SUMP, SUPER-FLO® 12" TOP WITH BUCKET

32330-SD SERIES with -SD Special-Duty Grate

APPLICATIONFor use in medium traffic areas, such as bottling plants, for any type of floor con-struction where a heavy flow of liquid is anticipated and a deep bucket is necessaryto collect a considerable amount of debris which may clog the waste line.

SPECIFICATIONJOSAM 32330 Series coated cast iron Floor Drain, deep two-piece body with doubledrainage flange, WEJLOC® non-puncturing flashing clamp collar, weepholes, bottomoutlet, round top and removable sediment bucket which supports a medium-dutyloose-set anti-tilting SUPER-FLO® grate with perimeter slots.

t -SD Special-Duty Grate-15 Chained Grate-VP Secured Grate, Vandal-

Proof Screws-19 C.I. Undergrate with

Satin Finish Nikaloy Top-20 C.I. Undergrate with

Satin Finish Bronze Top-44 Fixed Extension Collar,

C.I. (Specify Hgt.) on32330-SD Only, 1” Std.

-44-92 Fixed Extension Collar,Galv. (Specify Hgt.) on32330-SD Only, 1” Std.

-49 3/4" Primer Tap-50 1/2" Primer Tap-70 Less Bucket

(32330-SD Only)-84 Stainless Steel Mesh

Bucket Liner-88 Supplementary Strainer-92 Galv. Cast Iron Parts

OUTLETS:-66 No-Hub Side Outlet,

2"-6"-X Inside Caulk Outlet-Z No-Hub Outlet

Available Options

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

32330 SLOT WIDTH 9/16"32330-19 SLOT WIDTH 1/2"32330-20 SLOT WIDTH 1/2"

32330-SD SLOT WIDTH 1/2"32330-SD-19 SLOT WIDTH 1/4"32330-SD-20 SLOT WIDTH 1/4"

FOR OUTLET TYPE SPECIFY -X or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.32332 2 86 32335 5 8932333 3 87 32336 6 9032334 4 88 32338 8 92

FOR OUTLET TYPE SPECIFY -X or -ZTYPE NO. PIPE SIZE LBS.32332-SD 2 6532333-SD 3 6532334-SD 4 65

APPLICATIONFor use in heavy traffic areas such as truck garages and loading docks for any type offloor construction where a medium flow of liquid is anticipated. The deep sumpassures rapid drainage and accommodates a large capacity bucket to collect debris.

SPECIFICATIONJOSAM 32330-SD Series coated cast iron Floor Drain with double drainage flange,WEJLOC® non-puncturing flashing clamp collar, weepholes, bottom outlet, round top,removable sediment bucket and special-duty, loose-set grate.

t Product Illustration follows.

Floor Drains_08.qxd 3/27/08 9:32 AM Page 132

FLOOR DRAINS • Round TopsFLOOR DRAINS • Round Tops

133

FLOO

RD

RAIN

S

APPLICATIONFor use in extra heavy traffic areas, such as industrial plants or loading docks, for anytype of floor construction where a heavy flow of liquid is anticipated and a bucket isnecessary to collect debris which may clog the waste line.

SPECIFICATIONJOSAM 34720 Series coated cast iron Floor Drain with two-piece body, doubledrainage flange, WEJLOC® non-puncturing flashing clamp collar, weepholes, bottomoutlet, round top, removable sediment bucket, loose-set extra heavy-duty grate.

-7 Ductile Iron Grate-15 Chained Grate-VP Secured Grate,

Vandal-Proof Screws-19 C.I. Undergrate with

Satin Finish Nikaloy Top-20 C.I. Undergrate with

Satin Finish Bronze Top-49 3/4" Primer Tap

-50 1/2" Primer Tap-84 Stainless Steel Mesh

Bucket Liner-88 Supplementary Strainer-92 Galvanized Cast Iron Parts

OUTLETS:-66 No-Hub Side Outlet-X Inside Caulk Outlet-Z No-Hub Outlet

APPLICATIONFor use in extra heavy traffic areas, such as parking decks, industrial plants or loadingdocks, for any type of floor construction where a heavy flow of liquid is anticipated.

SPECIFICATIONJOSAM 34710 Series coated cast iron Floor Drain with two-piece body, WEJLOC®

non-puncturing flashing clamp collar, double drainage flange, weepholes, bottomoutlet, round top, extra heavy-duty, loose-set grate.

Available Options

Available Options

-AE LEVELEZE® Adjustable Extension-7 Ductile Iron Grate-15 Chained Grate-VP Secured Grate, Vandal-Proof

Screws-19 C.I. Undergrate with

Satin Finish Nikaloy Top-20 C.I. Undergrate with

Satin Finish Bronze Top-49 3/4" Primer Tap

-50 1/2" Primer Tap-88 Supplementary Strainer-92 Galvanized Cast Iron Parts-ARE Acid-Resisting Epoxy

OUTLETS:-T Threaded Outlet-X Inside Caulk Outlet-Y Hub Outlet with Gasket, 4"-Z No-Hub Outlet

1-1/16" SQ. HOLES.

1-1/16" SQ. HOLES.

34710 SERIES 15" EXTRA HEAVY-DUTY TOP

34720 SERIES 15" EXTRA HEAVY-DUTY TOP WITH BUCKET

CONFORMS WITH ASTM-C564.THIS DIM. IS 5-3/4" FOR 34718-T.

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS.

34714 4 7334715 5 7334716 6 7434718 8 76

FOR OUTLET TYPE SPECIFY X or -ZTYPE NO. PIPE SIZE LBS.

34723 3 8034724 4 8134725 5 8234726 6 83

Floor Drains_08.qxd 5/1/08 1:45 PM Page 133

APPLICATIONFor use in medium traffic areas, such as storage rooms, for any type of floor construc-tion where a heavy flow of liquid is anticipated and a deep bucket is necessary tocollect a considerable amount of debris which may clog the waste line. Design per-mits drainage even though bucket is filled. To ensure proper usage, grate cannot bereplaced without bucket.

SPECIFICATIONJOSAM 34920 Series coated cast iron Floor Drain with double drainage flange, weep-holes, bottom outlet, round top and removable sediment bucket designed so thatextra heavy-duty NON-CLOG grate cannot be replaced unless bucket is in position.

APPLICATIONFor use in heavy traffic areas, such as warehouses and storage rooms, for any type offloor construction where a square top complements construction or floor finish andwhere a small to medium flow of liquid is anticipated.

SPECIFICATIONJOSAM 35100 Series coated cast iron Floor Drain, two-piece body with doubledrainage flange and 1/2” primer tap with plug, WEJLOC® non-puncturing flashing col-lar, weepholes, bottom outlet, square top and heavy-duty, loose-set grate.

FLOOR DRAINS • Round Top/Square TopFLOOR DRAINS • Round Top/Square Top

134

34920 SERIES NON-CLOG 21" ROUND TOP WITH BUCKET

35100 SERIES 8" SQUARE TOP

-12 Square Top-12-1 Square Top, Nikaloy-12-2 Square Top, Bronze-15 Chained Grate-VP Secured Grate,

Vandal-Proof Screws-19 C.I. Undergrate with

Satin Finish Nikaloy Top-20 C.I. Undergrate with

Satin Finish Bronze Top-C Bolted Flashing

Clamp Device

-49 3/4" Primer Tap-50 1/2" Primer Tap-80 Perforated Stainless

Steel Basket-84 Stainless Steel Mesh

Bucket Liner-92 Galvanized Cast Iron Parts

OUTLETS:-66 No-Hub Side Outlet, 3"- 6"-T Threaded Outlet-X Inside Caulk Outlet

1-1/16" SQ. HOLES.

SLOT WIDTH 3/8"

-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-7 Ductile Iron Grate-15 Chained Grate-49 3/4" Primer Tap

1/2" Primer Tap, Std.-92 Galvanized Cast Iron Parts-ARE Acid-Resisting Epoxy

OUTLETS:-TSO Threaded Side Outlet-T Threaded Outlet-X Inside Caulk Outlet-Y Hub Outlet with Gasket-Z No-Hub Outlet

Available Options

FOR OUTLET TYPE SPECIFY -T or -XTYPE NO. PIPE SIZE E F LBS.

34923 3 14-3/4 16-7/8 25334924 4 14-3/4 16-3/4 25334925 5 15 16-7/8 25334926 6 15 17-3/4 25334928 8 15-1/4 17-3/4 253

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

Available Options

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS.

35102 2 3635103 3 3635104 4 36

CONFORMS WITH ASTM-C564.

FLO

OR

DRA

INS

Floor Drains_08.qxd 5/1/08 1:45 PM Page 134

FLOOR DRAINS • Square TopsFLOOR DRAINS • Square Tops

135

35130-14-1 SERIES with -14-1 Satin Finish Nikaloy Hinged Top

APPLICATIONFor use in medium traffic areas, such as equipment or storage rooms, for any type offloor construction where a square top complements construction or floor finish andwhere a small to medium flow of liquid is anticipated. The bucket collects debris,which may clog the waste line.

SPECIFICATIONJOSAM 35130 Series coated cast iron Floor Drain with two-piece body, flashingflange, seepage slots, bottom outlet, medium-duty secured grate and removable sedi-ment bucket. Top frame serves as clamp ring.

35130 SERIES 9" TOP WITH BUCKET

-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top

t -14-1 Hinged Top,Satin Finish Nikaloy

-14-2 Hinged Top,Satin Finish Bronze

-15 Chained Grate-VP Secured Grate,

Vandal-Proof Screws-49 3/4" Primer Tap-50 1/2" Primer Tap

-70 Less Bucket-84 Stainless Steel

Mesh Bucket Liner-92 Galvanized Cast Iron Parts-ARE Acid-Resisting Epoxy

OUTLETS:-66 No-Hub Side Outlet-X Inside Caulk Outlet-Z No-Hub Outlet

APPLICATIONFor use in medium traffic areas, such as equipment and storage rooms, for any typeof floor construction where a square top complements construction or floor finish andwhere a small to medium flow of liquid is anticipated. Hinged grate provides easyaccessibility to the bucket and the drain line. The bucket collects debris, which mayclog the waste line.

SPECIFICATIONJOSAM 35130-14-1 Series coated cast iron Floor Drain with two-piece body, flashingflange, seepage slots, bottom outlet, Nikaloy square top, medium-duty hinged grateand removable sediment bucket. Top frame serves as clamp ring.

Series 35130-14-2 with Satin Finish Bronze Hinged Top

OPTION N/A:-15

Available Options

SLOT WIDTH 3/8"

SLOT WIDTH 3/8"

FOR OUTLET TYPE SPECIFY -X or -ZTYPE NO. PIPE SIZE LBS.

35132 2 4735133 3 4735134 4 47

FOR OUTLET TYPE SPECIFY -X or -ZTYPE NO. PIPE SIZE LBS.

35132-14-1 2 4735133-14-1 3 4735134-14-1 4 47

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

t Product Illustration follows.

FLOO

R DRA

INS

Floor Drains_08.qxd 4/24/08 9:09 AM Page 135

FLOOR DRAINS • Square TopsFLOOR DRAINS • Square Tops

136

FLO

OR

DRA

INS

APPLICATIONFor use in medium traffic areas such as parking garages for any type of floor con-struction where a square top complements construction or floor finish and a mediumsump is needed to handle a moderate flow of liquid. The bucket protects the drainline from debris, and the deep-set tractor grate will not flip out under high-speedtraffic.

SPECIFICATIONJOSAM 35170 Series coated cast iron Floor Drain, bottom outlet, square top, medium-duty, loose-set tractor grate and removable bucket.

APPLICATIONFor use in medium traffic areas, such as decks and storage rooms, for any type offloor construction where a square top complements construction or floor finish and amedium flow of liquid is anticipated.

SPECIFICATIONJOSAM 37800 Series coated cast iron Floor Drain with flashing flange, and 1/2”primer tap with plug, shallow body, WEJLOC® non-puncturing flashing collar, weep-holes, bottom outlet, square top and heavy-duty, loose-set grate.

35170 SERIES 10" TRACTOR TOP WITH BUCKET

37800 SERIES SHALLOW SUMP, 12" HEAVY-DUTY TOP

Available Options-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-15 Chained Grate-VP Secured Grate,

Vandal-Proof Screws-49 3/4" Primer Tap-50 1/2" Primer Tap-70 Less Bucket-84 Stainless Steel Mesh

Bucket Liner-88 Supplementary Strainer-92 Galvanized Cast Iron Parts

OUTLETS:-X Inside Caulk Outlet-Z No-Hub Outlet

Available Options-7 Ductile Iron Grate-14 Hinged Grate-VP Secured Grate,

Vandal-Proof Screws-18 Hinged Grate with

Latching Device-19 C.I. Undergrate with

Satin Finish Nikaloy Top-20 C.I. Undergrate with

Satin Finish Bronze Top-49 3/4" Primer Tap

1/2" Primer Tap, Std.-92 Galvanized Cast Iron Parts

OUTLETS:-66 No-Hub Side Outlet-T Threaded Outlet-X Inside Caulk Outlet-Y Hub Outlet with Gasket-Z No-Hub Outlet

35170 SLOT WIDTH 7/16"35170-1 SLOT WIDTH 1/4"35170-2 SLOT WIDTH 1/4"

SLOT WIDTH 3/8"

FOR OUTLET TYPE SPECIFY -X or -ZTYPE NO. PIPE SIZE LBS.

35173 3 4435174 4 44

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS.

37802 2 5837803 3 5837804 4 58

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

CONFORMS WITH ASTM-C564.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

Floor Drains_08.qxd 3/27/08 9:32 AM Page 136

APPLICATIONFor use in medium traffic areas such as parking decks or industrial plants for any typeof floor construction where a square top complements construction or floor finish.Also, where a moderate to heavy flow of liquid is anticipated and a bucket is desiredto protect the drain line from debris.

SPECIFICATIONJOSAM 37810 Series coated cast iron Floor Drain, two-piece medium-deep body withdouble drainage flange, WEJLOC® non-puncturing flashing collar, weepholes, bottomoutlet, square top, heavy-duty, loose-set grate and removable sediment bucket.

APPLICATIONFor use in medium traffic areas such as parking decks or industrial plants for any typeof floor construction where a square top complements construction or floor finish.Also, where a moderate to heavy flow of liquid is anticipated and a bucket is desiredto protect the drain line from debris. The deep sump assures rapid drainage.

SPECIFICATIONJOSAM 37820 Series coated cast iron Floor Drain, two-piece deep body with doubledrainage flange, WEJLOC® non-puncturing flashing collar, weepholes, bottom outlet,square top, heavy-duty, loose-set grate and removable sediment bucket.

FLOOR DRAINS • Square TopsFLOOR DRAINS • Square Tops

137

FLOO

R DRA

INS

37810 SERIES MEDIUM SUMP, 12" HEAVY-DUTY TOP

37820 SERIES DEEP SUMP, 12" HEAVY-DUTY TOP & BUCKET

-AE LEVELEZE® Adjustable Ext.-4 Secondary Flashing Clamp

(Use with -AE only)-7 Ductile Iron Grate-14 Hinged Grate-VP Secured Grate,

Vandal-Proof Screws-18 Hinged Grate with

Latching Device-19 C.I. Undergrate with

Satin Finish Nikaloy Top-20 C.I. Undergrate with

Satin Finish Bronze Top-49 3/4" Primer Tap-50 1/2" Primer Tap

-70 Less Bucket-84 Stainless Steel Mesh

Bucket Liner-88 Supplementary Strainer-92 Galvanized Cast Iron Parts-ARE Acid-Resisting Epoxy

OUTLETS:-66 No-Hub Side Outlet-T Threaded Outlet-X Inside Caulk Outlet-Y Hub Outlet with Gasket,

2"-4"-Z No-Hub Outlet

-AE LEVELEZE® Adjustable Ext.-4 Secondary Flashing Clamp

(Use with -AE only)-7 Ductile Iron Grate-14 Hinged Grate-VP Secured Grate,

Vandal-Proof Screws-18 Hinged Grate with

Latching Device-19 C.I. Undergrate with

Satin Finish Nikaloy Top-20 C.I. Undergrate with

Satin Finish Bronze Top

-49 3/4" Primer Tap-50 1/2" Primer Tap-70 Less Bucket-84 Stainless Steel Mesh

Bucket Liner-88 Supplementary Strainer-92 Galvanized Cast Iron Parts-ARE Acid-Resisting Epoxy

OUTLETS:-66 No-Hub Side Outlet, 2"-6"-X Inside Caulk Outlet-Z No-Hub Outlet

Available Options

Available Options

SLOT WIDTH 3/8"

SLOT WIDTH 3/8"

CONFORMS WITH ASTM-C564.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.37812 2 56 37815 5 5637813 3 56 37816 6 5637814 4 56

GRATE FREE AREA 54 SQ. IN.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

FOR OUTLET TYPE SPECIFY -X or -ZTYPE NO. PIPE SIZE LBS. TYPE NO. PIPE SIZE LBS.37822 2 56 37825 5 6337823 3 58 37826 6 6537824 4 60 37828 8 67

Floor Drains_08.qxd 3/27/08 9:32 AM Page 137

APPLICATIONFor use in medium traffic areas, such as industrial plants or boiler rooms, for any typeof floor construction where a square top complements construction or floor finish anda large sump is needed to handle a moderate flow of liquid. The bucket protects thedrain line from large amounts of debris, and the latching hinged grate permits easyaccess for bucket removal.

SPECIFICATIONJOSAM 37830 Series coated cast iron Floor Drain with double drainage flange, seep-age slots, bottom outlet, square top, heavy-duty, hinged latching grate and removablesediment bucket.

FLOOR DRAINS • Square TopsFLOOR DRAINS • Square Tops

138

FLO

OR

DRA

INS

37830 SERIES EXTRA-DEEP SUMP, 12" HEAVY-DUTY TOP, LATCHING GRATE

APPLICATIONFor use in medium traffic areas such as boiler rooms for any type of floor constructionwhere a square top complements construction or floor finish and where a medium tolarge flow of liquid is anticipated. The bucket collects debris, which may clog thewaste line.

SPECIFICATIONJOSAM 37840 Series coated cast iron Floor Drain with double drainage flange, seep-age slots, bottom outlet, square top, heavy-duty secured grate and removable sedi-ment bucket. Top frame serves as clamp ring.

37840 SERIES EXTRA-DEEP SUMP, 12" HEAVY-DUTY TOP

-7 Ductile Iron Grate-19 Satin Finish Nikaloy Top-20 Satin Finish Bronze Top-21 Loose-Set Grate-22 Less Latching Device-49 3/4" Primer Tap-50 1/2" Primer Tap-69 Lift Handle for Sediment Bucket-84 Stainless Steel Mesh

Bucket Liner-92 Galvanized Cast Iron Parts

OUTLETS:-66 No-Hub Side Outlet-X Inside Caulk Outlet-Z No-Hub Outlet

-7 Ductile Iron Grate-14 Hinged Grate-VP Secured Grate,

Vandal-Proof Screws-19 C.I. Undergrate with

Satin Finish Nikaloy Top-20 C.I. Undergrate with

Satin Finish Bronze Top-49 3/4" Primer Tap-50 1/2" Primer Tap-70 Less Bucket-84 Stainless Steel Mesh

Bucket Liner-88 Supplementary Strainer-92 Galvanized Cast Iron Parts

OUTLETS:-66 No-Hub Side Outlet, 2"-6"-X Inside Caulk Outlet-Z No-Hub Outlet

Available Options

Available Options

FOR OUTLET TYPE SPECIFY -X or -ZTYPE NO. PIPE SIZE LBS.

37832 2 7337833 3 7437834 4 7437835 5 7437836 6 74

GRATE FREE AREA 54 SQ. IN.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

FOR OUTLET TYPE SPECIFY -X or -ZTYPE NO. PIPE SIZE LBS.

37842 2 7537843 3 7537844 4 7537845 5 7537846 6 7537848 8 75

GRATE FREE AREA 54 SQ. IN.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

SLOT WIDTH 3/8"

SLOT WIDTH 3/8"

Floor Drains_08.qxd 4/24/08 9:09 AM Page 138

FLOOR DRAINS • Square TopsFLOOR DRAINS • Square Tops

139

FLOO

R DRA

INS

APPLICATIONFor use in heavy traffic areas, such as packing houses or commercial parking decks forany type of floor construction where a medium to large flow of liquid is anticipatedand a bucket is necessary to collect debris which may clog the waste line. LEVELEZE®

adjustable collar permits accurate positioning of grate to meet finished floor level.

SPECIFICATIONJOSAM 37900 Series coated cast iron LEVELEZE® Floor Drain with square grate set insquare secured frame, grate support collar with double drainage flange and weep-holes, bottom outlet, adjustable collar, support ring, large sump body, removable sedi-ment bucket and heavy-duty ductile iron grate.

APPLICATIONFor use in medium traffic areas, such as industrial plants or boiler rooms, for any typeof floor construction where a square top complements construction or floor finish anda large sump is needed to handle a heavy flow of liquid. The secondary flat strainerprotects the drain line from debris.

SPECIFICATIONJOSAM 37960 Series coated cast iron Floor Drain with double drainage flange,weepholes, bottom outlet, inside caulk connection, square top, square medium-duty,loose-set, SUPER-FLO® grate and secondary strainer.

-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-7 Ductile Iron Grate-LG Less Grate, Cast Iron-LG-1 Less Grate, Nikaloy-LG-2 Less Grate, Bronze-11 Extra Heavy-Duty Grate-15 Chained Grate-LF Less Double Drainage

Flange-C Bolted Flashing Clamp

Device-49 3/4" Primer Tap-50 1/2" Primer Tap-81 Slotted Cast Iron Bucket-84 Stainless Steel Mesh

Bucket Liner

-92 Galvanized Cast Iron Parts-92-LF Galvanized Cast Iron Parts,

Less Double DrainageFlange

-92-LG-LF Galvanized Cast Iron Parts,Less Grate and Flange

-ARE Acid-Resisting Epoxy(See 49400 Series)

OUTLET:-X Inside Caulk Outlet

-4 Secondary Flashing Clamp -15 Chained Grate-VP Secured Grate,

Vandal-Proof Screws-19 Heavy-Duty Ductile Iron

Undergrate w/Satin FinishNikaloy Top

-20 Heavy-Duty Ductile Iron Undergrate w/Satin FinishBronze Top

-70 Less Bucket-84 Stainless Steel Mesh

Bucket Liner-88 Supplementary Strainer-92 Galvanized Cast Iron Parts

OUTLETS:-T Threaded Outlet-X Inside Caulk Outlet-Y Hub Outlet, 2"-4"-Z No-Hub Outlet

Available Options

Available Options

CONFORMS WITH ASTM-C564.n THIS DIM. IS 5-3/4" ON 37908-T.s WITH -4 SECONDARY FLASHING CLAMP 2-1/4” MIN. 4-1/4” MAX.

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

s 2" SIZE FURNISHED W/CAULK RING.ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

FOR OUTLET TYPE SPECIFY -T, -X, -Y or -ZTYPE NO. PIPE SIZE LBS.

37902 2 8237903 3 8237904 4 8137905 5 8137906 6 8037908 8 80

37960 SERIES SUPER-FLO® 16" TOP

37900 SERIES 14" PACKING HOUSE TYPE

FOR OUTLET TYPE SPECIFY -XTYPE NO. PIPE SIZE A LBS. LESS FLANGE LBS.

37962 2s 9-1/4 94 37962-LF 8537963 3 9-1/4 96 37963-LF 8637964 4 9-1/2 97 37964-LF 8737965 5 9-7/8 98 37965-LF 8837966 6 9-7/8 100 37966-LF 90

37900 SLOT WIDTH 5/16"37900-19 SLOT WIDTH 1/4"37900-20 SLOT WIDTH 1/4"

37960 SLOT WIDTH 9/16"37960-1 SLOT WIDTH 1/2"37960-2 SLOT WIDTH 1/2"

Floor Drains_08.qxd 4/24/08 9:09 AM Page 139

APPLICATIONFor use in moderate traffic areas, such as boiler rooms on or below grade where a deep seal trap protects against sewer gas and vermin and a floor level cleanoutfacilitates access to the drain line should blockage occur. The shallow side outletroughs in where limited space is available. A flapper type backwater valve is optionalfor areas where backflow is anticipated.

SPECIFICATIONJOSAM 38040 Series coated cast iron combination Floor Drain and integral deep sealtrap, side outlet spigot connection, round top, medium-duty, loose-set, SUPER-FLO®

grate and cleanout protected by a tractor cover.

APPLICATIONFor use in moderate traffic areas, such as basement storage rooms or any areas on or below grade where a deep seal trap protects against sewer gas and vermin and a floor level cleanout facilitates access to the drain line should blockage occur. Theball type backwater valve protects against backflow and the shallow side outletroughs in where limited space is available.

SPECIFICATIONJOSAM 38250A Series coated cast iron combination Floor Drain and integral deepseal trap, side outlet spigot connection, round top, medium-duty, loose-set grate,flush-with-floor cleanout and ball type backwater valve.

FLOOR DRAINS • Special ApplicationsFLOOR DRAINS • Special Applications

140

FLO

OR

DRA

INS

38040 SERIES ROUND TOP & CLEANOUT

38250A SERIES ROUND TOP WITH CLEANOUT & BWV

-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-7 Ductile Iron Grate-11 Extra-Heavy Grate, Cast Iron-15 Chained Grate-VP Secured Grate,

Vandal-Proof Screws-49 3/4" Primer Tap-50 1/2" Primer Tap-51 1-1/2" Auxiliary

Threaded Inlet-52 2" Auxiliary Threaded Inlet-60 Backwater Valve-81 Slotted Cast Iron Bucket-81-92 Slotted Cast Iron Bucket,

Galvanized

-84 Stainless Steel Mesh Bucket Liner

-88 Supplementary Strainer-92 Galvanized Cast Iron Parts

OUTLET:-Z No-Hub Outlet

-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-15 Chained Grate-VP Secured Grate,

Vandal-Proof Screws-61 Less Backwater Valve-92 Galvanized Cast Iron Parts

OUTLET:-Z No-Hub Outlet

Available Options

Available Options

38040 SLOT WIDTH 3/8"38040-1 SLOT WIDTH 3/16"38040-2 SLOT WIDTH 3/16"

SLOT WIDTH 7/16"

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

s NOTE: THE 38043 USES A 38044 BODY WITH A 4 X 3 REDUCING COUPLING.

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP, TYPES 38252A & 38253A.ADD 1/2" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP, TYPE 38254A.

FOR OUTLET TYPE SPECIFY -ZTYPE NO.

PIPESIZE B x B1 C E F G H J LBS.

38042 2 14-1/8 x 9 21-1/8 5-3/4 13-1/2 16-5/8 4 4-1/2 6338043 3s 16-1/4 x 9 23-7/8 6-3/4 17 19-3/8 5 4 6738044 4 16-1/4 x 9 23-7/8 6-3/4 17 19-3/8 5 4 70

FOR OUTLET TYPE SPECIFY -ZTYPE NO.

PIPESIZE B C D E F G FREE

AREA LBS.

38252A 2 9 15 8 4-1/2 11-7/8 10-1/2 17.7 1938253A 3 10 18 9 3-7/8 12-3/4 13 18.3 3738254A 4 12-1/4 21 11 5-3/8 15-5/8 15 29.4 56

Floor Drains_08.qxd 3/27/08 9:32 AM Page 140

APPLICATIONFor use in medium traffic areas such as bottling plants, on or below grade where a deep seal trap protects against sewer gas and vermin and a floor level cleanoutfacilitates access to the drain line should blockage occur. The shallow side outletroughs in where limited space is available and the large capacity bucket protects thedrain line from debris. A flapper type backwater valve is optional for areas wherebackflow is anticipated.

SPECIFICATIONJOSAM 38420 Series coated cast iron combination Floor Drain and integral deep sealtrap with double drainage flange, weepholes, side outlet hub connection, round top,flush-with-floor cleanout and removable sediment bucket with integral auxiliarydrainage rim designed so that medium-duty loose-set, NON-CLOG grate cannot bereplaced unless bucket is in position.

APPLICATIONFor use in heavy traffic areas such as commercial garages and hangars where volatileliquids that could create an explosion or fire may be present. The integral deep sealtrap, created by the funnel and solid bucket prevent gases from entering an occupiedarea. The vent expels gases before they can accumulate on top of liquid in the bucket.The flush-with-floor cleanout allows access to the drain line. A flapper type backwatervalve is optional for areas where backflow is anticipated.

SPECIFICATIONJOSAM 38420-IGS Series coated cast iron combination extra deep Floor Drain andintegral deep seal trap with double drainage flange, weepholes, side outlet and hubvent connection, round top, flush-with-floor cleanout, removable sediment bucket,funnel shaped internal seal with integral rim designed so that heavy-duty gratecannot be replaced unless funnel is in position.

FLOOR DRAINS • Special ApplicationsFLOOR DRAINS • Special Applications

141

FLOO

R DRA

INS

38420 SERIES NON-CLOG WITH CLEANOUT & BUCKET

38420-IGS SERIES with -IGS Internal Gas Seal

t -IGS Internal Gas Seal, 4" Size Only-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-15 Chained Grate-VP Secured Grate, Vandal-Proof Screws-C Bolted Flashing Clamp Device-60 Backwater Valve-84 Stainless Steel Mesh Bucket Liner-92 Galvanized Cast Iron Parts

Available Options

TYPE NO. PIPE SIZE LBS.38423 3 27038424 4 270

TYPE NO. PIPE SIZE LBS.38424-IGS 4 307

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

SLOT WIDTH 1/2"

SLOT WIDTH 1/2"

t Product Illustration follows.

Floor Drains_08.qxd 4/24/08 9:09 AM Page 141

APPLICATIONFor use in extra heavy traffic areas, such as garages and loading docks. The hingedrectangular grate permits easy access for fast and frequent removal of sedimentbucket and ensures that the grate cannot be removed from the drain site. Deep seal P trap with flush-floor cleanout provides direct access to the drain.

SPECIFICATIONJOSAM 38620-40 Series coated cast iron combination Floor Drain and deep seal trap,side outlet threaded connection, 12-7/8" x 10-7/8" top, flush-with-floor cleanout,removable medium-deep sediment bucket, and heavy-duty hinged grate.

APPLICATIONFor use in extra heavy traffic areas, such as garages and loading docks. The hingedrectangular grate permits easy access for fast and frequent removal of sedimentbucket and ensures that the grate cannot be removed from the drain site.

SPECIFICATIONJOSAM 38640 Series coated cast iron Floor Drain with side outlet hub connection, 12-7/8" x 10-7/8" top, removable sediment bucket and extra heavy-duty hinged grate.

FLOOR DRAINS • Special ApplicationsFLOOR DRAINS • Special Applications

142

FLO

OR

DRA

INS

38620-40 SERIES 13" X 11" TOP, DEEP SEAL TRAP & CLEANOUT

38640 SERIES 13" X 11" TOP WITH BUCKET & SIDE OUTLET

Available Options

Available Options

-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-7 Ductile Iron Grate-VP Secured Grate, Vandal-Proof Screws-33 Galvanized Bucket Only-49 3/4" Primer Tap-50 1/2" Primer Tap-60 Backwater Valve-70 Less Bucket-84 Stainless Steel Mesh Bucket Liner-92 Galvanized Cast Iron Parts

-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-7 Ductile Iron Grate-VP Secured Grate, Vandal-Proof Screws-70 Less Bucket-84 Stainless Steel Mesh Bucket Liner-92 Galvanized Cast Iron Parts

TYPE NO.

PIPESIZE C x C1 E F G M N LBS.

38623-40 3 19-1/2 x 10-7/8 7-1/8 17 14-1/4 5 5 8838624-40 4 20-1/2 x 10-7/8 6-5/8 18 15-3/8 5 6 99

SLOT WIDTH 9/16"

SLOT WIDTH 9/16"

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

TYPE NO. PIPE SIZE E F G LBS.38642 2 7 8-3/4 8 5838643 3 6-1/2 8-7/8 8-1/4 5838644 4 6 8-7/8 8-5/8 58

Floor Drains_08.qxd 5/1/08 1:45 PM Page 142

APPLICATIONFor use in medium traffic areas such as parking garages for any type of floor constructionwhere a rectangular top complements construction or floor finish and a medium sump isneeded to handle a moderate flow of liquid. The bucket protects the drain line from largeamounts of debris, and the deep-set tractor grate will not flip out under high-speed traffic.

SPECIFICATIONJOSAM 38820 Series coated cast iron Floor Drain with flashing flange, bottom outlet,15" x 13-1/8" top, removable deep sediment bucket and medium-duty loose-set tractorgrate. Top frame serves as clamp ring.

FLOOR DRAINS • Special ApplicationsFLOOR DRAINS • Special Applications

143

FLOO

R DRA

INS

TYPE NO. PIPE SIZE F J LBS.38833 3 8-7/8 5 11538834 4 9-3/8 4-1/2 125

FOR OUTLET TYPE SPECIFY -X or -ZTYPE NO. PIPE SIZE E F LBS.

38823 3 10-3/8 12-1/8 11738824 4 10-1/2 12-3/8 117

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

38820 SERIES 15" X 13" TOP, TRACTOR GRATE

38830 SERIES 13-3/4" X 14-1/8" TOP, BUCKET & INTERNAL TRAPAPPLICATION

For use in extra heavy traffic areas, such as garages and loading docks. The hingedrectangular grate permits easy access for fast and frequent removal of sedimentbucket and ensures that the grate cannot be removed from the drain site. Internalbronze cleanout provides direct access to the drain line.

SPECIFICATIONJOSAM 38830 Series coated cast iron combination Floor Drain and integral deep seal trap with double drainage flange, weepholes, side outlet hub connection,13-3/4" x 14-1/8" top, heavy-duty hinged grate, removable deep sediment bucketand internal bronze cleanout.

SLOT WIDTH 5/8"

SLOT WIDTH 5/8"

-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-7 Ductile Iron Grate-15 Chained Grate-49 3/4" Primer Tap-50 1/2" Primer Tap-74 Aluminum Bucket-84 Stainless Steel Mesh

Bucket Liner-92 Galvanized Cast Iron Parts

OUTLETS:-66 No-Hub Side Outlet-X Inside Caulk Outlet-Z No-Hub Spigot Outlet

Available Options

-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-7 Ductile Iron Grate-VP Secured Grate, Vandal-Proof Screws-49 3/4" Primer Tap-50 1/2" Primer Tap-84 Stainless Steel Mesh Bucket Liner-92 Galvanized Cast Iron Parts

Available Options

Floor Drains_08.qxd 3/27/08 9:32 AM Page 143

APPLICATIONFor use in heavy traffic areas, such as roadways, parking and trucking areas to handleboth heavy traffic loads and a large volume of surface water. Internal dome strainerprotects the waste line from debris.

SPECIFICATIONJOSAM 38850 Series coated cast iron Floor Drain, bottom outlet, inside caulk connection,22" x 14" top, heavy-duty, loose-set grate and removable internal dome strainer.

APPLICATIONFor use in heavy traffic areas such as packing houses where a shallow bottom outlet is desired. The integral trap protects against sewer gas and vermin and a floor levelcleanout facilitates access to the drain line should blockage occur. The bucket protectsthe drain line from debris.

SPECIFICATIONJOSAM 38930 Series coated cast iron combination Floor Drain and integral trap with double drainage flange, weepholes, bottom outlet, inside caulk connection,21" x 14-1/2" top, heavy-duty, loose-set grate, removable sediment bucket, and flush-with-floor cleanout.

FLOOR DRAINS • Special ApplicationsFLOOR DRAINS • Special Applications

144

FLO

OR

DRA

INS

38850 SERIES 22" X 14" TOP, INTERNAL DOME STRAINER

38930 SERIES 21" X 14-1/2" TOP, CLEANOUT & BUCKET

-7 Ductile Iron Grate-15 Chained Grate-VP Secured Grate, Vandal-Proof Screws-92 Galvanized Cast Iron Parts

OUTLET:-X Inside Caulk Outlet

-7 Ductile Iron Grate-15 Chained Grate-VP Secured Grate, Vandal-Proof Screws-C Bolted Flashing Clamp Device-84 Stainless Steel Mesh Bucket Liner-92 Galvanized Cast Iron Parts

OUTLET:-X Inside Caulk Outlet

Available Options

Available Options

SLOT WIDTH 13/16"

SLOT WIDTH 7/8"

FOR OUTLET TYPE SPECIFY -XTYPE NO. PIPE SIZE LBS.

38853 3s 24538854 4 24538855 5 24638856 6 247

FOR OUTLET TYPE SPECIFY -XTYPE NO. PIPE SIZE LBS.

38933 3s 12038934 4 120

s 3" SIZE FURNISHED WITH 4" BODY WITH REDUCING BUSHING.

s 3" SIZE FURNISHED WITH 4" BODY WITH REDUCING BUSHING.

Floor Drains_08.qxd 3/27/08 9:32 AM Page 144

APPLICATIONFor use in areas where it is desired to wash the interior of garbage and other canssuch as in commercial kitchens. The bronze spray nozzle cleanses the inside of thecan and the grate and bucket prevent solids from entering the waste line.

SPECIFICATIONJOSAM 39240 Series coated cast iron Can Wash Drain with double drainage flange,weepholes, bottom outlet, square top, removable sediment bucket and bronze spraynozzle assembly.

APPLICATIONFor use in planting areas or flower boxes. Secured beehive dome is covered withstainless steel mesh to ensure clear drainage and prevent soil or stones from enteringthe drain line.

SPECIFICATIONJOSAM 39600 Series coated cast iron Planting Area Drain with flashing flange andclamp device, bottom outlet, stainless mesh screen covered dome, secured in place by bolts.

FLOOR DRAINS • Special ApplicationsFLOOR DRAINS • Special Applications

145

FLOO

RD

RAIN

S

39240 SERIES SQUARE CAN WASH DRAIN

39600 SERIES PLANTING AREA DRAIN

-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-15 Chained Grate-C Bolted Flashing Clamp Device-84 Stainless Steel Mesh Bucket Liner-92 Galvanized Cast Iron Parts-98 Water Supply Control Box

OUTLETS:-66 No-Hub Side Outlet-X Inside Caulk Outlet-Z No-Hub Outlet

SLOT WIDTH 7/16"

GRATE FREE AREA 35 SQ. IN.

DRAWING DEPICTS -1 OR -2 OPTIONS.SUBTRACT 3/8” WHEN FURNISHED WITH STD. C.I. TOP.NOTE: VACUUM BREAKER SHOULD BE INSTALLED SUBJECT TO LOCAL CODES.

FOR OUTLET TYPE SPECIFY -X or -ZTYPE NO. PIPE SIZE LBS.

39243 3 5939244 4 59

Available Options

-89 Deck Clamp Assembly-92 Galvanized Cast Iron Parts

OUTLETS:-66 No-Hub Side Outlet-T Threaded Outlet-X Inside Caulk Outlet-Z No-Hub Outlet

Available Options

FOR OUTLET TYPE SPECIFY -T, -X or -ZTYPE NO. PIPE SIZE D E LBS.

39602 2 4-3/4 6-1/4 3039603 3 4-3/4 6-1/4 3039604 4 4-1/2 6-1/4 3039605 5 4-3/8 6 3039606 6 4 5-3/4 30

Floor Drains_08.qxd 5/1/08 1:45 PM Page 145

APPLICATIONFor use in pedestrian and light commercial traffic areas where waterproof traffic-bearing elastomeric covering is to be applied. Wide deck flange provides ample areafor bonding of composition floor covering and distributes the weight of the drainover a broad area for positive support. The large capacity bucket protects the drainline from debris.

SPECIFICATIONJOSAM 39720 Series coated cast iron Area Drain with composition deck flange, bottomoutlet, 11" round top, heavy-duty, loose-set grate and removable sediment bucket.

APPLICATIONFor use in pedestrian and light traffic areas, where a small amount of flow is anticipated.The hinged grate eliminates its removal and potential loss from the drain.

SPECIFICATIONJOSAM 39960 Series coated cast iron Floor Drain, bottom outlet, inside caulk connection,square top and round hinged grate.

FLOOR DRAINS • Special ApplicationsFLOOR DRAINS • Special Applications

146

FLO

OR

DRA

INS

39720 SERIES 11" TOP, COMPOSITION DECK FLANGE

39960 SERIES SQUARE TOP WITH HINGED GRATE

-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-7 Ductile Iron Grate-13 Dome Grate, Cast Iron-13-1 Dome Grate, Nikaloy-13-2 Dome Grate, Bronze-15 Chained Grate-VP Secured Grate, Vandal-Proof Screws-70 Less Bucket-92 Galvanized Cast Iron Parts

OUTLETS:-T Threaded Outlet-X Inside Caulk Outlet

-VP Secured Grate, Vandal-Proof Screws-ARE Acid-Resisting Epoxy-92 Galvanized Cast Iron Parts

OUTLET:-X Inside Caulk Outlet

Available Options

Available Options

FOR OUTLET TYPE SPECIFY -T or -XTYPE NO. PIPE SIZE LBS.

39722 2 6539723 3 6539724 4 65

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

39720 SLOT WIDTH 5/8"39720-1 SLOT WIDTH 1/2"39720-2 SLOT WIDTH 1/2"

1/2" ROUND HOLES

FOR OUTLET TYPE SPECIFY -XTYPE NO. PIPE SIZE B D F FREE AREA LBS.

39962 2 6 4-7/8 4-1/2 3.0 639963 3 9 7-3/8 6-1/8 6.6 1439964 4 12 10-1/8 7 11.4 20

Floor Drains_08.qxd 5/1/08 3:16 PM Page 146

147

STAINLESS STEEL PRODUCTSSTAINLESS STEEL PRODUCTSSTA

INLESS

STEEL

Universal1. Suitable solutions for concrete floors with or without tile, flexible sheet flooring, circular frame profiles and epoxy/composite floors.2. Wide range of hygienic stainless steel gratings suited for any load class.3. 0.787 inch frame height suitable for all types of tiled floors.4. Concrete anchor tabs assist in leveling and ensure a secure concrete installation.

Excellent Hygienic Properties5. Designed without corners or cavities inside, thus preventing bacteria growth.6. Smooth surface finish without burrs or sharp edges.7. For optimum strength and hygiene the underside of our square frame is reinforced with synthetic resin infill. Round frames are solid.

Filter Basket and Sediment Bucket8. Both have swing lift handles and can be removed for cleaning without touching the dirt in the bottom.9. Most drains can include both a water trap and filter basket.

Stainless Steel Product Features

8. & 9.

3.

5.

6

4

1.

7.

2.

Water Trap Design10. Excellent self-cleaning properties.11. Small water surface minimizes bacterial growth12. Easily removed for cleaning.

Stainless Steel Product Features

Stainless Steel_08.qxd 4/9/08 9:11 AM Page 147

148

STAINLESS STEEL • Pictorial Selection GuideSTAINLESS STEEL • Pictorial Selection Guide

FLOOR DRAINS30000-A-SS-TAdj. Floor Drain with Round Strainer

Page 151

30000-S-SS-TAdj. Floor Drainwith Square Strainer

Page 151

32100-SS-AE9" Top, Adj. Extension

Page 152

32100-SS-AE-819" Top, Adj. Extension & Bucket

Page 152

32200-SS12-1/4" Top

Page 153

SQUARE FLOOR SINKS KETTLE DRAIN

ROUND FLOOR SINKS CLEANOUT

STA

INLE

SSST

EEL

Stainless Steel_08.qxd 3/28/08 1:33 PM Page 148

Please see the current Josam Stainless Steel Drain Catalog forupdated detailed information.

Please see the current Josam Stainless Steel Drain Catalog forupdated detailed information.

149

STAINLESS STEEL PRODUCTSSTAINLESS STEEL PRODUCTSJosam Company manufactures a complete line of cast and fabricated stainless steel floor drains and cleanouts. Stainless steel is a sanitary, durable,corrosion-resistant, long-lasting material ideally suited for building applications designed for a life expectancy in excess of fifty years. All stainlesssteels have inherent corrosion resistance, but the austenitic groups of stainless steels have greater resistance. Josam products are manufacturedfrom high-grade austenitic stainless steel in grades 304, suitable for most environments such as food service, health care, pharmaceutical and powergenerating plants and 316L, suitable for more corrosive environments commonly found in laboratories. Josam cast stainless steel products meet therequirements of ASTM A-351-Grade CF8 and Josam fabricated stainless steel products meet the requirements of ASME A-112.3.1-93.

Note: Temperature concentration levels and duration of contact have a direct affect on the resistance of stainless steel to certain chemicals. Flushing small amounts of corro-sive chemicals with adequate amounts of water will improve the resistance of stainless steel corrosion from harmful chemicals. Each application should be carefully reviewedto determine the suitability of stainless steel for the project conditions.

STAIN

LESSSTEEL

STAINLESS STEEL ACID RESISTANCE CHART (ROOM TEMPERATURE ASSUMED. DATA SHOULD BE USED AS A GUIDE ONLY.)

Chemical 3I6L 304 Chemical 316L 304Acetic Acid, 100% A A Lead acetate A AAcetic Acid, (dilute ) 50% A A Magnesium chloride B BAcetic anhydride A A Magnesium sulfate A AAcetone A A Mercury A AAluminum chloride F F Methanol A AAluminum sulfate A F Methyl chloride A AAmmonium carbonate A A Methylene chloride B BAmmonium chloride B B Natphtalene A AAmmonium fluoride A A Nickel chloride B BAmmonium hydroxide A A Nickel sulfate A AAmyl chloride A A Nitric acid C CAniline A A Oxalic acid C CAniline hydrochloride F F Perchloric acid F FBarium chloride B B Phosphoric acid A ABarium hydroxide A A Picric acid A ABenzalhude A A Potassium bromide A ABenzene A A Potassium carbonate A ABenzoic acid A A Potassium chlorate A ABorax A A Potassium chloride B BBoric acid A A Potassium cyanide A ABromine F F Potassium hydroxide A AButane A A Potassium nitrate A AButyl acetate A A Potassium permaganate A AButyric acid A A Potassium sulfate A ACalcium bisulfate A A Potassium sulfide A ACalcium chloride B B Propylene dichloride A ACalcium hydroxide A A Silver nitrate A ACalcium hypochlorite B C Sodium acetate A ACarbon disulfide A A Sodium bicarbonate A ACarbon tetrachloride A A Sodium bisulfate A CChloroacetic acid (mono) F F Sodium bisulfite A AChloril acid F F Sodium bromide B BChlorine (dry) A A Sodium carbonate A AChlorobenzene A A Sodium chlorate A AChloroform B B Sodium cyanide A AChlorosulfonic acid B C Sodium fluoride A ACopper chloride B B Sodium hydroxide A ACopper nitrate A A Sodium hypochlorite F FCopper sulfate A A Sodium nitrate A AEther A A Sodium sulfate A AEthylene bromide A A Sodium sulfide A AEthyl chloride A A Sodium sulfite A AEthylene chloride A A Standus chloride B CFatty acids A A Sulfur A AFluorine A A Sulfur chloride A AFormaldehyde A A Sulfur dioxide A BFormic acid A A Sulfuric acid F FFurfural A A Sulfurous acid A CGallic acid A A Thionyl chloride A AHydro bromic acid F F Toluene A AHydro chloric acid F F Trichloroethylene A AHydrofluoric acid F F Turpentine A AHydrogen peroxide A A Xylene A AIodine wet F F Zinc sulfate A A

Stainless Steel_08.qxd 3/28/08 1:33 PM Page 149

150

STAINLESS STEEL PRODUCTSSTAINLESS STEEL PRODUCTSST

AIN

LESS

STEE

L

Josam cast stainless steel drains and cleanouts are regularly furnished with Schedule 40S butt-weld outlet connections. Butt-weld outlet connectionscan also be furnished in Schedule 10S and 80S as specified.

Schedule 10S Pipe Schedule 80 PipeSchedule 40 Pipe

Cast Stainless Steel Butt-Weld Outlet Connection Data

Unless optional materials are specified, standard material shown in Specification will be provided.

How To Order Stainless Steel Products

30004-6A-SS -T -80

Outlet Size

Strainer Size

Outlet Type, Threaded

Option, Perforated Stainless Steel Basket

EXAMPLE: Series No. 30000-A-SS-T Type No. 30004-6A-SS-T

10˚

A

B

DIA.

DIA.1/16 +

-1/32

30˚- 45˚

A

B

DIA.

DIA.1/16 +

-1/32

371/2 +- 21/2˚

A

B

DIA.

DIA.1/16 +

-1/32

371/2˚ +- 21/2˚

PIPESCHEDULE

PIPESIZE 2"

PIPESIZE 2"

PIPESIZE 3"

PIPESIZE 3"

PIPESIZE 4"

PIPESIZE 4"

PIPESIZE 6"

PIPESIZE 6"

PIPESIZE 8"

PIPESIZE 8"

Dimension A B A B A B A B A B

10S 2.157 2.375 3.260 3.50O 4.260 4.500 6.357 6.625 8.329 8.625

40S 2.067 2.375 3.068 3.500 4.026 4.500 6.065 6.625 7.981 8.625

80S 1.939 2.375 2.900 3.500 3.826 4.500 5.761 6.625 7.625 8.625

Stainless Steel_08.qxd 3/28/08 1:33 PM Page 150

CAST STAINLESS STEELCAST STAINLESS STEEL

151

STAIN

LESSSTEEL

30000-A-SS-T SERIES ADJUSTABLE FLOOR DRAIN WITH ROUND STRAINER

30000-S-SS-T SERIES ADJUSTABLE FLOOR DRAIN WITH SQUARE STRAINER

APPLICATIONFor use in corrosive environments in finished floor areas with pedestrian traffic, suchas toilet or shower rooms. Wide flange anchors drain body in concrete and works inconjunction with the clamp collar to redirect waste through the collar’s weepholes ifseepage occurs around the strainer. The WEJLOC® clamp provides a non-puncturingpositive bond of the waterproofing membrane to the drain body for applicationswhere floors with standing water are to be sealed off from areas below. The collar isalso invertible for extra vertical strainer adjustment to meet finished floor level.

SPECIFICATIONJOSAM 30000-A-SS-T Series Type 316 cast stainless steel Floor Drain, two-piece bodywith double drainage flange, WEJLOC® invertible flashing collar, weepholes, bottomoutlet threaded connection and adjustable round SUPER-FLO® strainer.

APPLICATIONFor use in corrosive environments in finished floor areas with pedestrian traffic, suchas toilet or shower rooms. Wide flange anchors drain body in concrete and works inconjunction with the clamp collar to redirect waste through the collar’s weepholes ifseepage occurs around the strainer. The WEJLOC® clamp provides a non-puncturingpositive bond of the waterproofing membrane to the drain body for applicationswhere floors with standing water are to be sealed off from areas below. The collar isalso invertible for extra vertical strainer adjustment to meet finished floor level.

SPECIFICATIONJOSAM 30000-S-SS-T Series Type 316 cast stainless steel Floor Drain, two-piece bodywith double drainage flange, WEJLOC® invertible flashing collar, weepholes, bottomoutlet connection and adjustable square SUPER-FLO® strainer.

Available Options-VP Secured Grate, Vandal-Proof Screws-49 3/4" Primer Tap-50 1/2” Primer Tap-80 Perforated Stainless Steel Basket

OUTLET:-T Threaded Outlet

Available Options-VP Secured Grate, Vandal-Proof Screws-49 3/4" Primer Tap-50 1/2” Primer Tap-80 Perforated Stainless Steel Basket

OUTLET:-T Threaded Outlet

TYPE NO.PIPESIZE

ADJUSTABLE STRAINER

LBS.†BADJUSTMENT FREE

AREAX Y30002, 3, 4-5A-SS-T 2, 3, 4 5 3/4 2-1/8 7.8 1430002, 3, 4-6A-SS-T 2, 3, 4 6 1-1/4 2-3/8 11.0 1530002, 3, 4-7A-SS-T 2, 3, 4 7 1-1/8 2-7/8 13.2 1630002, 3, 4-8A-SS-T 2, 3, 4 8 1-5/8 2-5/8 16.2 17† STRAINER WITH BODY

TYPE NO.PIPESIZE

ADJUSTABLE STRAINER

LBS.†BADJUSTMENT FREE

AREAX Y30002, 3, 4-5S-SS-T 2, 3, 4 5 7/8 1-7/8 9.1 1530002, 3, 4-6S-SS-T 2, 3, 4 6 7/8 2-1/4 13.8 1630002, 3, 4-8S-SS-T 2, 3, 4 8 1-1/4 2-1/2 24.5 21† STRAINER WITH BODY

Stainless Steel_08.qxd 3/28/08 1:33 PM Page 151

CAST STAINLESS STEELCAST STAINLESS STEEL

152

STA

INLE

SSST

EEL

APPLICATIONFor use in corrosive environments in moderate traffic areas, such as power plants,food processing plants, dairies, chemical plants, pharmaceutical research facilities orlaboratories for any type of floor construction where a medium flow of liquid is antic-ipated. LEVELEZE® adjustable collar permits accurate positioning of grate to meetfinished floor level.

SPECIFICATIONJOSAM 32100-SS-AE Series Type 316 cast stainless steel LEVELEZE® Floor Drain withdouble drainage flange, weepholes, round top, adjustable collar with rolled thread andloose-set anti-tilting SUPER-FLO® grate with perimeter drainage slots, bottom outletand butt weld connection for schedule 40 pipe.

32100-SS-AE SERIES LEVELEZE® SUPER-FLO® FLOOR DRAIN

t -81 Shallow Stainless Steel Sediment Bucket-1 Satin Finish Nikaloy Grate-8 Solid Cover-9 Stainless Steel Mesh Screen on Underside of Grate-21 4” Diameter Funnel-22 6” Diameter Funnel-23 9” x 3” Oval Funnel-25 Stainless Steel Recessed Closure Plug-26 Molded ABS Recessed Closure Plug-34 “T” Handle for Recessed Plug-61 Flashing Clamp Device

OUTLET:-69 Schedule 10 S Butt Weld Connection

Available Options

SLOT WIDTH 15/32"

FOR OUTLET TYPE, SPECIFY BUTT WELDTYPE NO. PIPE SIZE A LBS.

32102-SS-AE 2 1-7/8 3532103-SS-AE 3 2 3632104-SS-AE 4 2-1/8 37

FOR OUTLET TYPE, SPECIFY BUTT WELDTYPE NO. PIPE SIZE A LBS.

32102-SS-AE-81 2 1-7/8 3832103-SS-AE-81 3 2 3832104-SS-AE-81 4 2-1/8 38

APPLICATIONFor use in corrosive environments in moderate traffic areas, such as power plants, foodprocessing plants, dairies, chemical plants, pharmaceutical research facilities or labora-tories for any type of floor construction where a medium flow of liquid is anticipatedand a bucket is necessary to collect debris, which may clog the waste line. LEVELEZE®

adjustable collar permits accurate positioning of grate to meet finished floor level.

SPECIFICATIONJOSAM 32100-SS-AE-81 Series Type 316 cast stainless steel LEVELEZE® Floor Drain withdouble drainage flange, weepholes, round top, adjustable collar with rolled thread andloose-set anti-tilting SUPER-FLO® grate with perimeter drainage slots, shallow sedimentbucket, bottom outlet and butt weld connection for schedule 40 pipe.

32100-SS-AE-81 SERIES LEVELEZE® SUPER-FLO® with -81 Bucket

t Product Illustration follows.

Stainless Steel_08.qxd 3/28/08 1:33 PM Page 152

CAST STAINLESS STEELCAST STAINLESS STEEL

153

STAIN

LESSSTEEL

FOR OUTLET TYPE, SPECIFY BUTT WELDTYPE NO. PIPE SIZE A LBS.32203-SS 3 2-1/8 4732204-SS 4 2-1/4 4832206-SS 6 2-5/8 50

APPLICATIONFor use in corrosive environments in moderate to heavy traffic areas, such as powerplants, food processing plants, dairies, chemical plants, pharmaceutical research facili-ties or laboratories for any type of floor construction where a medium to heavy flowof liquid is anticipated.

SPECIFICATIONJOSAM 32200-SS Series Type 316 cast stainless steel Floor Drain with double drainageflange, weepholes, round top, loose-set anti-tilting grate, bottom outlet, butt weldconnection for schedule 40 pipe.

32200-SS SERIES FLOOR DRAIN

Available Options

SLOT WIDTH 1/2"

-8 Solid Cover-9 S.S. Mesh Screen on Underside of Grate-22 6” Diameter Funnel-25 Stainless Steel Recessed Closure Plug-26 Molded ABS Recessed Closure Plug-34 “T” Handle for Recessed Plug-61 Flashing Clamp Device

OUTLET:-69 Schedule 10 S Butt Weld Connection

Stainless Steel_08.qxd 3/28/08 1:33 PM Page 153

CAST STAINLESS STEELCAST STAINLESS STEEL

157

STAIN

LESSSTEEL

FOR OUTLET TYPE, SPECIFY BUTT WELDTYPE NO. PIPE SIZE B C D LBS.56672-SS 2 2-7/8 3-3/4 1-1/2 356673-SS 3 4 4-7/8 1-1/2 756674-SS 4 5 6 1-5/8 756676-SS 6 7-1/4 8-3/8 1-5/8 10

APPLICATIONFor use in corrosive environments for floors subject to pedestrian or light wheel trafficwhere direct access to drain or waste line is desired. A threaded flanged plug main-tains the gas and watertight seal and is removable by the use of a spanner wrench.

SPECIFICATIONJOSAM 56670-SS Series Type 316 cast stainless steel round flush Cleanout withflanged ring and scoriated spanner type flanged screw plug, bottom outlet, butt weldconnection for schedule 40 pipe.

56670-SS SERIES CLEANOUT

Available Options-45 Spanner Wrench

OUTLET:-69 Schedule 10 S Butt Weld Connection

Stainless Steel_08.qxd 3/28/08 1:33 PM Page 157

159

SANITARY FLOOR SINKSSANITARY FLOOR SINKSFLO

OR

SINKS

Now, more than ever before, facilities such as hospitals, laboratories and areas where foods are processed and handled, are objectively evaluatedfor optimum environmental sanitation. Recognizing this requirement, JOSAM developed the SUPER-FLO-SEPTOR® line of Sanitary Floor Sinks.

SUPER-FLO-SEPTOR® Features

ACID-RESISTING INTERIORThe acid-resisting interior, furnished standard on all SUPER-FLO-SEPTORS®,provides the smooth surface necessary forsanitation and protection from corrosionin food processing applications.

INTERNAL DOMESUPER-FLO-SEPTORS® have an internal domewhich acts as a secondary strainer to inter-cept debris which could cause blockage ofdrain lines. The dome is easily removed tofacilitate cleaning.

SUPER-FLO® GRATE AND SANITARY SLOPING RIMThis unique combination insures that the rim portion and side walls of the drain willbe washed clean with any flow of liquid.

DOUBLE DRAINAGE OR ANCHORING FLANGEWhen this flange is provided, weepholesare automatically furnished to assure the drainage of any secondary moisturewhich may be present. The additional option of a flashing clamp device assures the positive bonding of the flashing between the double drainage flange and clamp ring.

BODYSanitation is promoted by the smooth,uniformly contoured interior which has nocorners or crevices to escape the cleansingaction of drainage flow. Available in depthsof 6, 8 and 10 inches (depending on series)to suit every application.

Outlet ConnectionsJOSAM SUPER-FLO-SEPTORS® are furnished with outlets for connection to extra-heavy, service weight or no-hub pipe. The timesaving, economicalJIFFEE-JOINT is used for inside caulk connections. For outlet type, specify (-X) for inside caulk outlet and (-Z) for no-hub spigot outlet.

Floor Sinks_08.qxd 3/27/08 9:58 AM Page 159

SANITARY FLOOR SINKS • Pictorial GuideSANITARY FLOOR SINKS • Pictorial Guide

160

SQUARE • NICKEL BRONZE TOPS49300-NB8"Top, 6" Deep Body49300-LF-NB Less Flange

Page 163

49320A-NB12"Top, 6" Deep Body49320A-LF-NB Less Flange

Page 165

49340A-NB12"Top, 8" Deep Body49340A-LF-NB Less Flange

Page 167

49360A-NB12"Top, 10" Deep Body49360A-LF-NB Less Flange

Page 169

49400-NB16"Top, 6" Deep Body49400-LF-NB Less Flange

Page 171

49420-NB16"Top, 12" Deep Body49420-LF-NB Less Flange

Page 173

SQUARE • ARE TOPS493008" Top, 6" Deep Body49300-LF Less Flange

Page 162

49320A12" Top, 6" Deep Body49320A-LF Less Flange

Page 164

49340A12" Top, 8" Deep Body49340A-LF Less Flange.

Page 166

49360A12" Top, 10" Deep Body49360A-LF Less Flange

Page 168

4940016"Top, 6" Deep Body49400-LF Less Flange

Page 170

4942016" Top, 12" Deep Body49420-LF Less Flange

Page 172

ROUND • ARE TOPS ROUND • NICKEL BRONZE TOPS495008" Top, 3" Deep Body49500-LF Less Flange

Page 174

49520A8" Top, 6" Deep Body49520A-LF Less Flange

Page 176

49580A12" Top, 8" Deep Body49580A-LF Less Flange

Page 178

49500-NB8" Top, 3" Deep Body49500-LF-NB Less Flange

Page 175

49520A-NB8" Top, 6" Deep Body49520A-LF-NB Less Flange

Page 177

49580A-NB12" Top, 8" Deep Body49580A-LF-NB Less Flange

Page 179

RECTANGULAR CAN WASH DRAINS497004” x 8" Top, 4" Deep Body49700-LF Less Flange

Page 180

49700-NB4” x 8" Top, 4" Deep Body49700-LF-NB Less Flange

Page 181

497206" X 12" Top, 7" Deep Body49720-LF Less Flange

Page 182

49720-NB6" x 12" Top, 7" Deep Body49720-LF-NB Less Flange

Page 183

4985012" Top Flushing RimHinged Grate

Page 184

49870A12" Top 8" Deep BodySpray Nozzle Assembly

Page 184

FLO

OR

SIN

KS

Floor Sinks_08.qxd 3/27/08 9:58 AM Page 160

161

SANITARY FLOOR SINKSSANITARY FLOOR SINKSHow To Order

EXAMPLE: Series No. 49320A-NB Type No. 49324A-NB

49324A-NB -Z -VP -31

Outlet Size

Outlet Type, No-Hub Spigot Outlet

Option, Secured Cover, Vandal-Proof Screws

Option, Sediment Bucket (Aluminum)

Unless optional materials are specified, standard material shown in Specification will be provided. Last digit indicates outlet size.

Typical Installations

(-C) BOLTED FLASHINGCLAMP DEVICEused on sanitary floor sinks withdouble drainage flanges to pro-vide a positive bond of the water-proofing membrane to the floorsink body.

(-3) OPTION, 1/2 GRATEreceives discharge lines for con-densate wastes or from equip-ment with additional drainagefrom floor area. The open portioncan be situated under equipmentwhile grate portion is exposed totraffic.

(-8) OPTION, DEPRESSEDGRATEserves as a shallow sedimentbucket to intercept solids in areaswhere limited space betweenfloor sink and equipment preventsthe use of a standard removablebucket.

(-31) OPTION, ALUMINUMSEDIMENT BUCKETfor use in food processing areasproducing solids such as peelings,food scraps, seeds, pits and otherdebris which could cause drainline blockage.

Options

49320A-NB Series SUPER-FLO-SEPTOR® Floor Sink shown installedin a heavy-duty structural concrete finish floor.

49580A-NB Series SUPER-FLO-SEPTOR® Floor Sink shown installedin a poured concrete floor on the ground level.

FLOO

RSIN

KS

Floor Sinks_08.qxd 3/27/08 9:58 AM Page 161

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

162

FLO

OR

SIN

KS

t Product Illustration follows.

APPLICATIONFor use in non-traffic areas where ultimate sanitation is desired, such as kitchens,hospitals and food processing plants. The 7-1/4" square grate and medium sumpaccept moderate flow and the dome strainer intercepts debris which could block thedrain line. Double drainage flange serves as an anchor in the sub-floor and redirectssecondary moisture to the waste line. It may also be used with a clamp device toassure a bond between the drain and the flashing or waterproof membrane.

SPECIFICATIONJOSAM 49300 Series square cast iron 5-7/8" deep SUPER-FLO-SEPTOR® Floor Sinkwith acid-resisting interior, double drainage flange with weepholes, bottom outlet,aluminum internal dome strainer and cast iron, non-traffic, acid-resisting, anti-tilting,SUPER-FLO® Grate.

49300 SERIES SUPER-FLO® 8” SQUARE TOP, 6” DEEP

For Options, See Below

APPLICATIONFor use in non-traffic areas where ultimate sanitation is desired, such as kitchens,hospitals and food processing plants. The 7-1/4" square grate and medium sumpaccept moderate flow and the dome strainer intercepts debris which could block thedrain line.

SPECIFICATIONJOSAM 49300-LF Series square cast iron 5-7/8" deep SUPER-FLO-SEPTOR® Floor Sinkwith acid-resisting interior, bottom outlet, aluminum internal dome strainer and castiron, non-traffic, acid-resisting, anti-tilting, SUPER-FLO® Grate.

-31 Sediment Bucket (Aluminum)-33 Sediment Bucket (A.R. Finish)

s -35 Stainless Steel Mesh Bucket Liner-43 Internal Dome Strainer (A.R. Finish)-45 Less Internal Dome Strainer-55 1/2” Primer Adapter, 88450 Provided-C Clamp Device, 49300, 49300-NB

OUTLETS-X Inside Caulk Outlet-Z No-Hub Outlet

s Specify -31 or -33 Bucket

OPTIONS N/A: -VP, -8, -20, -24

OPTIONS N/A: -VP, -8, -20, -24, -C

FOR OUTLET TYPE, SPECIFY -X or -Z.GRATE FREE AREA 21 SQ. IN.

FOR OUTLET TYPE, SPECIFY -X or -Z.

GRATE FREE AREA 21 SQ. IN.

49300-LF SERIES Less Flange

49302 2 2449303 3 2449304 4 24

TYPE NO. PIPE SIZE LBS

TYPE NO. PIPE SIZE LBS

t -LF Less Flanget -NB Nickel Bronze Traffic Top

-LG Less Grate-3 1/2 Grate-4 3/4 Grate-7 Full Grate with 2-1/2” Center Opening-8 Stainless Steel Depressed Grate, NB-VP Secured Grate, Vandal-Proof Screws, NB-16 Grate with 4” Round Funnel-17 Grate with 6” Round Funnel-18 Grate with 9” x 3-1/2” Oval Funnel-20 Solid Nikaloy Cover, NB-24 Chained Grate, NB

OPTIONS

49302-LF 2 2049303-LF 3 2049304-LF 4 21

SLOT WIDTH 7/16”

SLOT WIDTH 7/16”

Floor Sinks_08.qxd 5/1/08 2:41 PM Page 162

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

163

FLOO

RSIN

KS

FOR OUTLET TYPE, SPECIFY -X or -Z.

FOR OUTLET TYPE, SPECIFY -X or -Z.

49300-LF-NB SERIES Less Flange, with -NB Nikaloy Traffic Top

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipatedand ultimate sanitation is desired, such as kitchens, hospitals and food processingplants. The 7-1/4" square grate and medium sump accept moderate flow and thedome strainer intercepts debris which could block the drain line. Double drainageflange serves as an anchor in the sub-floor and redirects secondary moisture to thewaste line. It may also be used with a clamp device to assure a bond between thedrain and the flashing or waterproof membrane.

SPECIFICATIONJOSAM 49300-NB Series square cast iron 6-1/4" deep SUPER-FLO-SEPTOR® Floor Sinkwith acid-resisting interior, double drainage flange with weepholes, bottom outlet,aluminum internal dome strainer, Nikaloy sanitary sloped rim and Nikaloy light-duty,anti-tilting, SUPER-FLO® Grate.

49300-NB SERIES with -NB Nikaloy Traffic Top

TYPE NO. PIPE SIZE LBS.

49302-NB 2 2749303-NB 3 2749304-NB 4 27

TYPE NO. PIPE SIZE LBS.

49302-LF-NB 2 2449303-LF-NB 3 2449304-LF-NB 4 25

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipatedand ultimate sanitation is desired, such as kitchens, hospitals and food processingplants. The 7-1/4" square grate and medium sump accept moderate flow and thedome strainer intercepts debris which could block the drain line.

SPECIFICATIONJOSAM 49300-LF-NB Series square cast iron 6-1/4" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, aluminum internal dome strainer, Nikaloy sanitarysloped rim and Nikaloy light-duty, anti-tilting, SUPER-FLO® Grate.

OPTION N/A: -C

SLOT WIDTH 1/2”

SLOT WIDTH 1/2”

GRATE FREE AREA 22 SQ. IN.

GRATE FREE AREA 22 SQ. IN.

Floor Sinks_08.qxd 3/27/08 9:58 AM Page 163

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

164

FLO

OR

SIN

KS

t Product Illustration follows.

49320A-LF SERIES Less Flange

APPLICATIONFor use in non-traffic areas where ultimate sanitation is desired, such as kitchens,hospitals and food processing plants. The 9" square grate and medium sump acceptmoderate flow and the dome strainer intercepts debris which could block the drainline. Double drainage flange serves as an anchor in the sub-floor and redirects sec-ondary moisture to the waste line. It may also be used with a clamp device to assurea bond between the drain and the flashing or waterproof membrane.

SPECIFICATIONJOSAM 49320A Series square cast iron 5-7/8" deep SUPER-FLO-SEPTOR® Floor Sinkwith acid-resisting interior, double drainage flange with weepholes, bottom outlet,aluminum internal dome strainer and cast iron, non-traffic, acid-resisting, anti-tiltinggrate.

49320A SERIES 12” SQUARE TOP, 6” DEEP

49322A 2 4549323A 3 4549324A 4 4549326A 6 45

TYPE NO. PIPE SIZE LBS.

49322A-LF 2 2849323A-LF 3 2849324A-LF 4 2849326A-LF 6 28

For Options, See Below

APPLICATIONFor use in non-traffic areas where ultimate sanitation is desired, such as kitchens,hospitals and food processing plants. The 9" square grate and medium sump acceptmoderate flow and the dome strainer intercepts debris which could block the drainline.

SPECIFICATIONJOSAM 49320A-LF Series square cast iron 5-7/8" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, bottom outlet, aluminum internal dome strainer andcast iron, non-traffic, acid-resisting, anti-tilting grate.

t -LF Less Flanget -NB Nickel Bronze Traffic Top

-LG Less Grate-3 1/2 Grate-4 3/4 Grate-5 Nikaloy Extra Heavy-Duty Grate & Rim (Not SUPER-FLO® Design)-7 Full Grate with 2-1/2” Center Opening-8 Stainless Steel Depressed Grate, NB-VP Secured Grate, Vandal-Proof Screws, NB-15 Stainless Steel Rim and Grate, NB-16 Grate with 4” Round Funnel-17 Grate with 6” Round Funnel-18 Grate with 9” x 3-1/2” Oval Funnel-20 Solid Nikaloy Cover, NB-24 Chained Grate, NB

-31 Sediment Bucket (Aluminum)-33 Sediment Bucket (A.R. Finish)

s -35 Stainless Steel Mesh Bucket Liner-43 Internal Dome Strainer (A.R. Finish)-45 Less Internal Dome Strainer-55 1/2” Primer Adaptor, 88450 Provided for 2"- 4"

1/2" Primer Tap, 6"-C Clamp Device, 49320A, 49320A-NB

OUTLETS-X Inside Caulk Outlet-Y Hub Outlet with Gasket, 2”-4”-Z No-Hub Outlet

s Specify -31 or -33 Bucket

OPTIONS N/A: -VP, -8, -20, -24

OPTIONS N/A: -VP, -8, -20, -24, -C

SLOT WIDTH 3/8”

SLOT WIDTH 3/8”

GRATE FREE AREA 26 SQ. IN.

FOR OUTLET TYPE, SPECIFY -X, -Y or -Z.

GRATE FREE AREA 26 SQ. IN.

FOR OUTLET TYPE, SPECIFY -X, -Y or -Z.

OPTIONS

TYPE NO. PIPE SIZE LBS.

Floor Sinks_08.qxd 5/1/08 4:14 PM Page 164

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

165

FLOO

RSIN

KS

FOR OUTLET TYPE, SPECIFY -X, -Y or -Z.

FOR OUTLET TYPE, SPECIFY -X, -Y or -Z.

49320A-LF-NB SERIES Less Flange, with -NB Nikaloy Traffic Top

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipatedand ultimate sanitation is desired, such as kitchens, hospitals and food processingplants. The 10" square grate and medium sump accept moderate flow and the domestrainer intercepts debris which could block the drain line. Double drainage flangeserves as an anchor in the sub-floor and redirects secondary moisture to the wasteline. It may also be used with a clamp device to assure a bond between the drain andthe flashing or waterproof membrane.

SPECIFICATIONJOSAM 49320A-NB Series square cast iron 6-1/4" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, double drainage flange with weepholes, bottom out-let, aluminum internal dome strainer, Nikaloy sanitary sloped rim and Nikaloy light-duty, anti-tilting, SUPER-FLO® Grate.

49320A-NB SERIES with -NB Nikaloy Traffic Top

TYPE NO. PIPE SIZE LBS.

49322A-NB 2 4549323A-NB 3 4549324A-NB 4 4549326A-NB 6 45

TYPE NO. PIPE SIZE LBS.49322A-LF-NB 2 2849323A-LF-NB 3 2849324A-LF-NB 4 2849326A-LF-NB 6 28

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipatedand ultimate sanitation is desired, such as kitchens, hospitals and food processingplants. The 10" square grate and medium sump accept moderate flow and the domestrainer intercepts debris which could block the drain line.

SPECIFICATIONJOSAM 49320A-LF-NB Series square cast iron 6-1/4" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, bottom outlet, aluminum internal dome strainer,Nikaloy sanitary sloped rim and Nikaloy light-duty, anti-tilting, SUPER-FLO® Grate.

OPTION N/A: -C

SLOT WIDTH 1/2”

SLOT WIDTH 1/2”

GRATE FREE AREA 35 SQ. IN.

GRATE FREE AREA 35 SQ. IN.

Floor Sinks_08.qxd 3/27/08 9:58 AM Page 165

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

166

FLO

OR

SIN

KS

FOR OUTLET TYPE, SPECIFY -X, -Y or -Z.

GRATE FREE AREA 26 SQ. IN.

t Product Illustration follows.

49340A-LF SERIES Less Flange

APPLICATIONFor use in non-traffic areas where ultimate sanitation is desired, such as kitchens,hospitals and food processing plants. The 10" square grate and medium sump acceptmoderate to heavy flow and the dome strainer intercepts debris which could blockthe drain line. Double drainage flange serves as an anchor in the sub-floor and redi-rects secondary moisture to the waste line. It may also be used with a clamp deviceto assure a bond between the drain and the flashing or waterproof membrane.

SPECIFICATIONJOSAM 49340A Series square cast iron 8" deep SUPER-FLO-SEPTOR® Floor Sink withacid-resisting interior, double drainage flange with weepholes, bottom outlet, alu-minum internal dome strainer and cast iron, non-traffic, acid-resisting, anti-tiltinggrate.

49340A SERIES 12” SQUARE TOP, 8” DEEP

49342A 2 5049343A 3 5049344A 4 50

TYPE NO. PIPE SIZE LBS.

49342A-LF 2 3349343A-LF 3 3349344A-LF 4 33

APPLICATIONFor use in non-traffic areas where ultimate sanitation is desired, such as kitchens,hospitals and food processing plants. The 10" square grate and medium sump acceptmoderate to heavy flow and the dome strainer intercepts debris which could blockthe drain line.

SPECIFICATIONJOSAM 49340A-LF Series square cast iron 8" deep SUPER-FLO-SEPTOR® Floor Sinkwith acid-resisting interior, bottom outlet, aluminum internal dome strainer and castiron, non-traffic, acid-resisting, anti-tilting grate.

t -LF Less Flanget -NB Nickel Bronze Traffic Top

-LG Less Grate-3 1/2 Grate-4 3/4 Grate-5 Nikaloy Extra Heavy-Duty Grate & Rim (Not SUPER-FLO® Design)-7 Full Grate with 2-1/2” Center Opening-8 Stainless Steel Depressed Grate, NB-VP Secured Grate, Vandal-Proof Screws, NB-15 Stainless Steel Rim and Grate-16 Grate with 4” Round Funnel-17 Grate with 6” Round Funnel-18 Grate with 9” x 3-1/2” Oval Funnel-20 Solid Nikaloy Cover, NB-24 Chained Grate, NB

OPTIONS-31 Sediment Bucket (Aluminum)-33 Sediment Bucket (A.R. Finish)

s -35 Stainless Steel Mesh Bucket Liner-43 Internal Dome Strainer (A.R. Finish)-45 Less Internal Dome Strainer-55 1/2” Primer Adapter, 88450 Provided-C Clamp Device, 49340A, 49340A-NB

OUTLETS-X Inside Caulk Outlet-Y Hub Outlet with Gasket-Z No-Hub Outlet

s Specify -31 or -33 Bucket

OPTIONS N/A: -VP, -8, -20, -24

OPTIONS N/A: -VP, -8, -20, -24, -C

SLOT WIDTH 3/8”

SLOT WIDTH 3/8”

FOR OUTLET TYPE, SPECIFY -X, -Y or -Z.

GRATE FREE AREA 26 SQ. IN.

For Options, See Below

TYPE NO. PIPE SIZE LBS.

Floor Sinks_08.qxd 5/1/08 2:41 PM Page 166

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

167

FLOO

RSIN

KS

FOR OUTLET TYPE, SPECIFY -X, -Y or -Z.

FOR OUTLET TYPE, SPECIFY -X, -Y or -Z.

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

49340A-LF-NB SERIES Less Flange, with -NB Nikaloy Traffic Top

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipatedand ultimate sanitation is desired, such as kitchens, hospitals and food processingplants. The 10" square grate and medium sump accept moderate to heavy flow andthe dome strainer intercepts debris which could block the drain line. Double drainageflange serves as an anchor in the sub-floor and redirects secondary moisture to thewaste line. It may also be used with a clamp device to assure a bond between thedrain and the flashing or waterproof membrane.

SPECIFICATIONJOSAM 49340A-NB Series square cast iron 8-3/8" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, double drainage flange with weepholes, bottom out-let, aluminum internal dome strainer, Nikaloy sanitary sloped rim and Nikaloy, light-duty, anti-tilting, SUPER-FLO® Grate.

49340A-NB SERIES with -NB Nikaloy Traffic Top

TYPE NO. PIPE SIZE LBS.

49342A-NB 2 5049343A-NB 3 5049344A-NB 4 50

TYPE NO. PIPE SIZE LBS.

49342A-LF-NB 2 3349343A-LF-NB 3 3349344A-LF-NB 4 33

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipatedand ultimate sanitation is desired, such as kitchens, hospitals and food processingplants. The 10" square grate and medium sump accept moderate to heavy flow andthe dome strainer intercepts debris which could block the drain line.

SPECIFICATIONJOSAM 49340A-LF-NB Series square cast iron 8-3/8" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, bottom outlet, aluminum internal dome strainer,Nikaloy sanitary sloped rim and Nikaloy, light-duty, anti-tilting, SUPER-FLO® Grate.

OPTION N/A: -C

SLOT WIDTH 1/2”

SLOT WIDTH 1/2”

GRATE FREE AREA 35 SQ. IN.

GRATE FREE AREA 35 SQ. IN.

Floor Sinks_08.qxd 3/27/08 9:58 AM Page 167

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

168

FLO

OR

SIN

KS

FOR OUTLET TYPE, SPECIFY -X, -Y or -Z.

t Product Illustration follows.

49360A-LF SERIES Less Flange

APPLICATIONFor use in non-traffic areas where ultimate sanitation is desired, such as kitchens,hospitals and food processing plants. The 9" square grate and deep sump acceptheavy flow and the dome strainer intercepts debris which could block the drain line.Double drainage flange serves as an anchor in the sub-floor and redirects secondarymoisture to the waste line. It may also be used with a clamp device to assure a bondbetween the drain and the flashing or waterproof membrane.

SPECIFICATIONJOSAM 49360A Series square cast iron 9-7/8" deep SUPER-FLO-SEPTOR® Floor Sinkwith acid-resisting interior, double drainage flange with weepholes, bottom outlet,aluminum internal dome strainer and cast iron, non-traffic, acid-resisting, anti-tiltinggrate.

49360A SERIES 12” SQUARE TOP, 10” DEEP

TYPE NO. PIPE SIZE LBS.

49362A 2 6249363A 3 6549364A 4 65

TYPE NO. PIPE SIZE LBS.

49362A-LF 2 5349363A-LF 3 5549364A-LF 4 56

For Options, See Below

APPLICATIONFor use in non-traffic areas where ultimate sanitation is desired, such as kitchens,hospitals and food processing plants. The 9" square grate and deep sump acceptheavy flow and the dome strainer intercepts debris which could block the drain line.

SPECIFICATIONJOSAM 49360A-LF Series square cast iron 9-7/8" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, bottom outlet, aluminum internal dome strainer andcast iron, non-traffic, acid-resisting, anti-tilting grate.

t -LF Less Flanget -NB Nickel Bronze Traffic Top

-LG Less Grate-3 1/2 Grate-4 3/4 Grate-5 Nikaloy Extra Heavy-Duty Grate & Rim (Not SUPER-FLO® Design)-7 Full Grate with 2-1/2” Center Opening-8 Stainless Steel Depressed Grate, NB-VP Secured Grate, Vandal-Proof Screws, NB-15 Stainless Steel Rim and Grate-16 Grate with 4” Round Funne-17 Grate with 6” Round Funnel-18 Grate with 9” x 3-1/2” Oval Funnel-20 Solid Nikaloy Cover, NB-24 Chained Grate, NB

OPTIONS-31 Sediment Bucket (Aluminum)-32 Shallow Sediment Bucket (Aluminum)-33 Sediment Bucket (A.R. Finish)

s -35 Stainless Steel Mesh Bucket Liner-43 Internal Dome Strainer (A.R. Finish)-45 Less Internal Dome Strainer-55 1/2” Primer Adapter, 88450 Provided-C Clamp Device, 49360A, 49360A-NB

OUTLETS-X Inside Caulk Outlet-Y Hub Outlet with Gasket-Z No-Hub Outlet

s Specify -31 or -33 Bucket

OPTIONS N/A: -VP, -8, -20, -24

OPTIONS N/A: -VP, -8, -20, -24, -C

SLOT WIDTH 3/8”

SLOT WIDTH 3/8”

GRATE FREE AREA 26 SQ. IN.

FOR OUTLET TYPE, SPECIFY -X, -Y or -Z.

GRATE FREE AREA 26 SQ. IN.

Floor Sinks_08.qxd 5/1/08 2:41 PM Page 168

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

169

FLOO

RSIN

KS

FOR OUTLET TYPE, SPECIFY -X, -Y or -Z.GRATE FREE AREA 35 SQ. IN.

FOR OUTLET TYPE, SPECIFY -X, -Y or -Z.

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

49360A-LF-NB SERIES Less Flange, with -NB Nikaloy Traffic Top

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipatedand ultimate sanitation is desired, such as kitchens, hospitals and food processingplants. The 10" square grate and deep sump accept heavy flow and the dome strain-er intercepts debris which could block the drain line. Double drainage flange servesas an anchor in the sub-floor and redirects secondary moisture to the waste line. Itmay also be used with a clamp device to assure a bond between the drain and theflashing or waterproof membrane.

SPECIFICATIONJOSAM 49360A-NB Series square cast iron 10-1/4" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, double drainage flange with weepholes, bottom out-let, aluminum internal dome strainer, Nikaloy sanitary sloped rim and Nikaloy light-duty, anti-tilting, SUPER-FLO® Grate.

49360A-NB SERIES with -NB Nikaloy Traffic Top

TYPE NO. PIPE SIZE LBS.

49362A-NB 2 6949363A-NB 3 7249364A-NB 4 72

TYPE NO. PIPE SIZE LBS.

49362A-LF-NB 2 6049363A-LF-NB 3 6249364A-LF-NB 4 63

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipatedand ultimate sanitation is desired, such as kitchens, hospitals and food processingplants. The 10" square grate and deep sump accept heavy flow and the dome strain-er intercepts debris which could block the drain line.

SPECIFICATIONJOSAM 49360A-LF-NB Series square cast iron 10-1/4" deep SUPER-FLO-SEPTOR®

Floor Sink with acid-resisting interior, bottom outlet, aluminum internal dome strainer,Nikaloy sanitary sloped rim and Nikaloy light-duty, anti-tilting, SUPER-FLO® Grate.

OPTION N/A: -C

SLOT WIDTH 1/2”

SLOT WIDTH 1/2”

GRATE FREE AREA 35 SQ. IN.

Floor Sinks_08.qxd 3/27/08 9:58 AM Page 169

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

170

FLO

OR

SIN

KS

GRATE FREE AREA 94 SQ. IN.

GRATE FREE AREA 94 SQ. IN.

t Product Illustration follows.

49400-LF SERIES Less Flange

APPLICATIONFor use in non-traffic areas where ultimate sanitation is desired, such as kitchens,hospitals, laundries and food processing plants. The 14-1/2" square grate and medi-um sump accept heavy flow and the dome strainer intercepts debris which couldblock the drain line. Double drainage flange serves as an anchor in the sub-floor andredirects secondary moisture to the waste line. It may also be used with a clampdevice to assure a bond between the drain and the flashing or waterproof membrane.

SPECIFICATIONJOSAM 49400 Series square cast iron 6" deep SUPER-FLO-SEPTOR® Floor Sink withacid-resisting interior, double drainage flange with weepholes, bottom outlet, alu-minum internal dome strainer, cast iron, non-traffic, acid-resisting, anti-tilting SUPER-FLO® Grate.

49400 SERIES 16” SQUARE TOP, 6” DEEP

TYPE NO. PIPE SIZE B DIM. LBS.

49403 3 9-1/4 9949404 4 9-1/2 9649406 6 9-7/8 97

TYPE NO. PIPE SIZE B DIM. LBS.

For Options, See Below

APPLICATIONFor use in non-traffic areas where ultimate sanitation is desired, such as kitchens,hospitals, laundries and food processing plants. The 14-1/2" square grate and medi-um sump accept heavy flow and the dome strainer intercepts debris which couldblock the drain line.

SPECIFICATIONJOSAM 49400-LF Series square cast iron 6" deep SUPER-FLO-SEPTOR® Floor Sinkwith acid-resisting interior, bottom outlet, aluminum internal dome strainer, cast iron,non-traffic, acid-resisting, anti-tilting SUPER-FLO® Grate.

s -35 Stainless Steel Mesh Bucket Liner-43 Internal Dome Strainer (A.R. Finish)-45 Less Internal Dome Strainer-55 1/2” Primer Adapter, 88450 Provided for 3”,4”-55 1/2” Primer Tap, 6”-C Clamp Device, 49400, 49400-NB

OUTLET-X Inside Caulk Outlet

s Specify -31 or -33 BucketNOTE: For painted or galvanized inside and outside, see 37960 Series.

OPTION N/A: -VP

OPTIONS N/A: -VP, -C

SLOT WIDTH 9/16”

SLOT WIDTH 9/16”

FOR OUTLET TYPE, SPECIFY -X.

FOR OUTLET TYPE, SPECIFY -X.

49403-LF 3 9-1/4 6549404-LF 4 9-1/2 6749406-LF 6 9-7/8 70

t -LF Less Flanget -NB Nickel Bronze Traffic Top

-LG Less Grate-3 1/2 Grate-4 3/4 Grate-7 Full Grate with 2-1/2” Center Opening-VP Secured Grate, Vandal-Proof Screws, NB-16 Grate with 4” Round Funnel-17 Grate with 6” Round Funnel-18 Grate with 9” x 3-1/2” Oval Funnel-31 Sediment Bucket (Aluminum)-33 Sediment Bucket (A.R. Finish)

OPTIONS

Floor Sinks_08.qxd 5/1/08 2:41 PM Page 170

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

171

FLOO

RSIN

KS

FOR OUTLET TYPE, SPECIFY -X.

FOR OUTLET TYPE, SPECIFY -X.

49400-LF-NB SERIES Less Flange, with -NB Nikaloy Traffic Top

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipatedand ultimate sanitation is desired, such as kitchens, hospitals, laundries and food pro-cessing plants. The 14-1/2" square grate and medium sump accept heavy flow andthe dome strainer intercepts debris which could block the drain line. Double drainageflange serves as an anchor in the sub-floor and redirects secondary moisture to thewaste line. It may also be used with a clamp device to assure a bond between thedrain and the flashing or waterproof membrane.

SPECIFICATIONJOSAM 49400-NB Series square cast iron 6-1/4" deep SUPER-FLO-SEPTOR® Floor Sinkwith acid-resisting interior, double drainage flange with weepholes, bottom outlet,aluminum internal dome strainer, Nikaloy sanitary sloped rim and Nikaloy, light-duty,anti-tilting, SUPER-FLO® Grate.

49400-NB SERIES with -NB Nikaloy Traffic Top

TYPE NO. PIPE SIZE B DIM. LBS.

49403-NB 3 9-1/2 11049404-NB 4 9-3/4 10749406-NB 6 10-1/8 107

TYPE NO. PIPE SIZE B DIM. LBS.

49403-LF-NB 3 9-1/2 7649404-LF-NB 4 9-3/4 7749406-LF-NB 6 10-1/8 80

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipatedand ultimate sanitation is desired, such as kitchens, hospitals, laundries and food pro-cessing plants. The 14-1/2" square grate and medium sump accept heavy flow andthe dome strainer intercepts debris which could block the drain line.

SPECIFICATIONJOSAM 49400-LF-NB Series square cast iron 6-1/4" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, bottom outlet, aluminum internal dome strainer,Nikaloy sanitary sloped rim and Nikaloy, light-duty, anti-tilting, SUPER-FLO® Grate.

OPTION N/A: -C

SLOT WIDTH 1/2”

SLOT WIDTH 1/2”

GRATE FREE AREA 93 SQ. IN.

GRATE FREE AREA 93 SQ. IN.

Floor Sinks_08.qxd 3/27/08 9:58 AM Page 171

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

172

FLO

OR

SIN

KS

FOR OUTLET TYPE, SPECIFY -X.

49423 3 15-1/4 11749424 4 15-1/2 11849426 6 15-7/8 121

GRATE FREE AREA 94 SQ. IN.

t Product Illustration follows.

49420-LF SERIES Less Flange

APPLICATIONFor use in non-traffic areas where ultimate sanitation is desired, such as kitchens,hospitals, laundries and food processing plants. The 14-1/2" square grate and deepsump accept very heavy flow and the dome strainer intercepts debris which couldblock the drain line. Double drainage flange serves as an anchor in the sub-floor andredirects secondary moisture to the waste line. It may also be used with a clampdevice to assure a bond between the drain and the flashing or waterproof membrane.

SPECIFICATIONJOSAM 49420 Series square cast iron 12" deep SUPER-FLO-SEPTOR® Floor Sink withacid-resisting interior, double drainage flange with weepholes, bottom outlet, alu-minum internal dome strainer and cast iron, non-traffic, acid-resisting, anti-tilting,SUPER-FLO® Grate.

49420 SERIES 16” SQUARE TOP, 12” DEEP

TYPE NO. PIPE SIZE B DIM. LBS.

TYPE NO. PIPE SIZE B DIM. LBS.

49423-LF 3 15-1/4 9849424-LF 4 15-1/2 9849426-LF 6 15-7/8 98

For Options, See Below

APPLICATIONFor use in non-traffic areas where ultimate sanitation is desired, such as kitchens,hospitals, laundries and food processing plants. The 14-1/2" square grate and deepsump accept very heavy flow and the dome strainer intercepts debris which couldblock the drain line.

SPECIFICATIONJOSAM 49420-LF Series square cast iron 12" deep SUPER-FLO-SEPTOR® Floor Sinkwith acid-resisting interior, bottom outlet, aluminum internal dome strainer and castiron, non-traffic, acid-resisting, anti-tilting, SUPER-FLO® Grate.

s -35 Stainless Steel Mesh Bucket Liner-43 Internal Dome Strainer (A.R. Finish)-45 Less Internal Dome Strainer-51 Galvanized Cast Iron Inside and Outside-52 Painted Inside and Outside-55 1/2” Primer Adapter, 88450 Provided for 3”, 4”-55 1/2” Primer Tap, 6”-C Clamp Device, 49420, 49420-NB

OUTLET-X Inside Caulk Outlet

s Specify -31 or -33 Bucket

OPTIONS N/A: -C, -VP

SLOT WIDTH 9/16”

SLOT WIDTH 9/16”

FOR OUTLET TYPE, SPECIFY -X.

GRATE FREE AREA 94 SQ. IN.

t -LF Less Flanget -NB Nickel Bronze Traffic Top

-LG Less Grate-3 1/2 Grate-4 3/4 Grate-7 Full Grate with 2-1/2” Center Opening-VP Secured Grate, Vandal-Proof Screws, NB-16 Grate with 4” Round Funnel-17 Grate with 6” Round Funnel-18 Grate with 9” x 3-1/2” Oval Funnel-31 Sediment Bucket (Aluminum)-33 Sediment Bucket (A.R. Finish)

OPTIONS

OPTION N/A: -VP

Floor Sinks_08.qxd 5/1/08 2:41 PM Page 172

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

173

FLOO

RSIN

KS

FOR OUTLET TYPE, SPECIFY -X.

FOR OUTLET TYPE, SPECIFY -X.

49420-LF-NB SERIES Less Flange, with -NB Nikaloy Traffic Top

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipatedand ultimate sanitation is desired, such as kitchens, hospitals, laundries and food pro-cessing plants. The 14-1/2" square grate and deep sump accept very heavy flow andthe dome strainer intercepts debris which could block the drain line. Double drainageflange serves as an anchor in the sub-floor and redirects secondary moisture to thewaste line. It may also be used with a clamp device to assure a bond between thedrain and the flashing or waterproof membrane.

SPECIFICATIONJOSAM 49420-NB Series square cast iron 12-1/4" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, double drainage flange with weepholes, bottom out-let, aluminum internal dome strainer, Nikaloy sanitary sloped rim and Nikaloy, light-duty, anti-tilting, SUPER-FLO® Grate.

49420-NB SERIES with -NB Nikaloy Traffic Top

TYPE NO. PIPE SIZE B DIM. LBS.

49423-NB 3 15-1/2 12849424-NB 4 15-3/4 12949426-NB 6 16-1/4 132

TYPE NO. PIPE SIZE B DIM. LBS.

49423-LF-NB 3 15-1/2 10949424-LF-NB 4 15-3/4 10849426-LF-NB 6 16-1/4 108

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipatedand ultimate sanitation is desired, such as kitchens, hospitals, laundries and food pro-cessing plants. The 14-1/2" square grate and deep sump accept very heavy flow andthe dome strainer intercepts debris which could block the drain line.

SPECIFICATIONJOSAM 49420-LF-NB Series square cast iron 12-1/4" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, bottom outlet, aluminum internal dome strainer,Nikaloy sanitary sloped rim and Nikaloy, light-duty, anti-tilting, SUPER-FLO® Grate.

OPTION N/A: -C

SLOT WIDTH 1/2”

SLOT WIDTH 1/2”

GRATE FREE AREA 93 SQ. IN.

GRATE FREE AREA 93 SQ. IN.

Floor Sinks_08.qxd 3/27/08 9:58 AM Page 173

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

174

FLO

OR

SIN

KS

GRATE FREE AREA 15.5 SQ. IN.

t Product Illustration follows.

49500-LF SERIES Less Flange

APPLICATIONFor use in non-traffic areas where ultimate sanitation is desired, such as kitchens,hospitals and food processing plants. The 7-1/4" diameter grate and shallow sumpaccept light flow and the dome strainer intercepts debris which could block the drainline. Double drainage flange serves as an anchor in the sub-floor and redirects sec-ondary moisture to the waste line. It may also be used with a clamp device to assurea bond between the drain and the flashing or waterproof membrane.

SPECIFICATIONJOSAM 49500 Series round cast iron 3-5/16" deep SUPER-FLO-SEPTOR® Floor Sinkwith acid-resisting interior, double drainage flange with weepholes, bottom outlet,aluminum internal dome strainer and cast iron, non-traffic, acid-resisting, anti-tilting,SUPER-FLO® Grate.

49500 SERIES SUPER-FLO® 8” ROUND TOP, 3” DEEP

TYPE NO. PIPE SIZE LBS.

49502 2 1549503 3 1649504 4 17

TYPE NO. PIPE SIZE LBS.49502-LF 2 1449503-LF 3 1549504-LF 4 15

APPLICATIONFor use in non-traffic areas where ultimate sanitation is desired, such as kitchens,hospitals and food processing plants. The 7-1/4" diameter grate and shallow sumpaccept light flow and the dome strainer intercepts debris which could block the drainline.

SPECIFICATIONJOSAM 49500-LF Series round cast iron 3-5/16" deep SUPER-FLO-SEPTOR® Floor Sinkwith acid-resisting interior, bottom outlet, aluminum internal dome strainer and castiron, non-traffic, acid-resisting, anti-tilting, SUPER-FLO® Grate.

s -35 Stainless Steel Mesh Bucket Liner-43 Internal Dome Strainer (A.R. Finish)-45 Less Internal Dome Strainer-51 Galvanized Cast Iron Inside and Outside-52 Painted Inside and Outside-55 1/2” Primer Adaptor, 88450 Provided-C Clamp Device, 49500, 49500-NB

OUTLET-X Inside Caulk Outlet

s Specify -31 or -33 Bucket

OPTIONS N/A: -VP, -8

OPTIONS N/A: -VP, -C, -8

SLOT WIDTH 7/16”

SLOT WIDTH 7/16”

GRATE FREE AREA 15.5 SQ. IN.

FOR OUTLET TYPE, SPECIFY -X.

FOR OUTLET TYPE, SPECIFY -X.

For Options, See Below

t -LF Less Flanget -NB Nickel Bronze Traffic Top

-LG Less Grate-3 1/2 Grate-4 3/4 Grate-7 Full Grate with 2-1/2” Center Opening-8 Dep[ressed Grate (Aluminum), NB-VP Secured Grate, Vandal-Proof Screws, NB-16 Grate with 4” Round Funnel-17 Grate with 6” Round Funnel-18 Grate with 9” x 3-1/2” Oval Funnel-31 Sediment Bucket (Aluminum)-33 Sediment Bucket (A.R. Finish)

OPTIONS

Floor Sinks_08.qxd 5/1/08 4:14 PM Page 174

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

175

FLOO

RSIN

KS

FOR OUTLET TYPE, SPECIFY -X.

FOR OUTLET TYPE, SPECIFY -X.

175

49500-LF-NB SERIES Less Flange, with -NB Nikaloy Traffic Top

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipatedand ultimate sanitation is desired, such as kitchens, hospitals and food processingplants. The 7-1/4" diameter grate and shallow sump accept light flow and the domestrainer intercepts debris which could block the drain line. Double drainage flangeserves as an anchor in the sub-floor and redirects secondary moisture to the wasteline. It may also be used with a clamp device to assure a bond between the drain andthe flashing or waterproof membrane.

SPECIFICATIONJOSAM 49500-NB Series round cast iron 3-9/16" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, double drainage flange with weepholes, bottom out-let, aluminum internal dome strainer, Nikaloy sanitary sloped rim and Nikaloy, light-duty, anti-tilting, SUPER-FLO® Grate.

49500-NB SERIES with -NB Nikaloy Traffic Top

TYPE NO. PIPE SIZE LBS.

49502-NB 2 1949503-NB 3 19

. 49504-NB 4 20

TYPE NO. PIPE SIZE LBS.

49502-LF-NB 2 1749503-LF-NB 3 1849504-LF-NB 4 18

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipatedand ultimate sanitation is desired, such as kitchens, hospitals and food processingplants. The 7-1/4" diameter grate and shallow sump accept light flow and the domestrainer intercepts debris which could block the drain line.

SPECIFICATIONJOSAM 49500-LF-NB Series round cast iron 3-9/16" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, bottom outlet, aluminum internal dome strainer,Nikaloy sanitary sloped rim and Nikaloy, light-duty, anti-tilting, SUPER-FLO® Grate.

OPTION N/A: -C

SLOT WIDTH 3/8”

SLOT WIDTH 3/8”

GRATE FREE AREA 17 SQ. IN.

GRATE FREE AREA 17 SQ. IN.

Floor Sinks_08.qxd 3/27/08 9:58 AM Page 175

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

176

FLO

OR

SIN

KS

49522A 2 1949523A 3 1949524A 4 21

FOR OUTLET TYPE, SPECIFY -X.

FOR OUTLET TYPE, SPECIFY -X.

t Product Illustration follows.

49520A-LF SERIES Less Flange

APPLICATIONFor use in non-traffic areas where ultimate sanitation is desired, such as kitchens,hospitals and food processing plants. The 7-1/4" diameter grate and medium sumpaccept light flow and the dome strainer intercepts debris which could block the drainline. Double drainage flange serves as an anchor in the sub-floor and redirects sec-ondary moisture to the waste line. It may also be used with a clamp device to assurea bond between the drain and the flashing or waterproof membrane.

SPECIFICATIONJOSAM 49520A Series round cast iron 6" deep SUPER-FLO-SEPTOR® Floor Sink withacid-resisting interior, double drainage flange with weepholes, bottom outlet, alu-minum internal dome strainer, cast iron, non-traffic, acid-resisting, anti-tilting, SUPER-FLO® Grate.

49520A SERIES SUPER-FLO® 8” ROUND TOP, 6” DEEP

TYPE NO. PIPE SIZE LBS.

TYPE NO. PIPE SIZE LBS.

For Options, See Below

APPLICATIONFor use in non-traffic areas where ultimate sanitation is desired, such as kitchens,hospitals and food processing plants. The 7-1/4" diameter grate and medium sumpaccept light flow and the dome strainer intercepts debris which could block the drainline.

SPECIFICATIONJOSAM 49520A-LF Series round cast iron 6" deep SUPER-FLO-SEPTOR® Floor Sinkwith acid-resisting interior, bottom outlet, aluminum internal dome strainer, cast iron,non-traffic, acid-resisting, anti-tilting, SUPER-FLO® Grate.

t -LF Less Flanget -NB Nickel Bronze Traffic Top

-LG Less Grate-3 1/2 Grate-4 3/4 Grate-7 Full Grate with 2-1/2” Center Opening-8 Depressed Grate, (Aluminum), NB-VP Secured Grate, Vandal-Proof Screws, NB-16 Grate with 4” Round Funnel-17 Grate with 6” Round Funnel-18 Grate with 9” x 3-1/2” Oval Funnel-31 Sediment Bucket (Aluminum)-33 Sediment Bucket (A.R. Finish)

OPTIONSs -35 Stainless Steel Mesh Bucket Liner

-43 Internal Dome Strainer (A.R. Finish)-45 Less Internal Dome Strainer-51 Galvanized Cast Iron Inside and Outside-52 Painted Inside and Outside-55 1/2” Primer Adapter, 88450 Provided-C Clamp Device, 49520A, 49520A-NB

OUTLET-X Inside Caulk Outlet

s Specify -31 or -33 Bucket

OPTIONS N/A: -VP, -8

OPTIONS N/A: -VP, -C, -8

SLOT WIDTH 7/16”

SLOT WIDTH 7/16”

GRATE FREE AREA 15.5 SQ. IN.

GRATE FREE AREA 15.5 SQ. IN.

49522A-LF 2 1749523A-LF 3 1849524A-LF 4 18

Floor Sinks_08.qxd 5/1/08 4:14 PM Page 176

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

177

FLOO

RSIN

KS

FOR OUTLET TYPE, SPECIFY -X.

FOR OUTLET TYPE, SPECIFY -X.

177

49520A-LF-NB SERIES Less Flange, with -NB Nikaloy Traffic Top

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipatedand ultimate sanitation is desired, such as kitchens, hospitals and food processingplants. The 7-1/4" diameter grate and medium sump accept light flow and the domestrainer intercepts debris which could block the drain line. Double drainage flangeserves as an anchor in the sub-floor and redirects secondary moisture to the wasteline. It may also be used with a clamp device to assure a bond between the drain andthe flashing or waterproof membrane.

SPECIFICATIONJOSAM 49520A-NB Series round cast iron 6-1/4" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, double drainage flange with weepholes, bottom out-let, aluminum internal dome strainer, Nikaloy sanitary sloped rim and Nikaloy, light-duty, anti-tilting, SUPER-FLO® Grate.

49520A-NB SERIES with -NB Nikaloy Traffic Top

TYPE NO. PIPE SIZE LBS.49522A-NB 2 2249523A-NB 3 2249524A-NB 4 24

TYPE NO. PIPE SIZE LBS.

49522A-LF-NB 2 2049523A-LF-NB 3 2149524A-LF-NB 4 22

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipatedand ultimate sanitation is desired, such as kitchens, hospitals and food processingplants. The 7-1/4" diameter grate and medium sump accept light flow and the domestrainer intercepts debris which could block the drain line.

SPECIFICATIONJOSAM 49520A-LF-NB Series round cast iron 6-1/4" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, bottom outlet, aluminum internal dome strainer,Nikaloy sanitary sloped rim and Nikaloy, light-duty, anti-tilting, SUPER-FLO® Grate.

OPTION N/A: -C

SLOT WIDTH 3/8”

SLOT WIDTH 3/8”

GRATE FREE AREA 17 SQ. IN.

GRATE FREE AREA 17 SQ. IN.

Floor Sinks_08.qxd 3/27/08 9:58 AM Page 177

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

178

FLO

OR

SIN

KS

FOR OUTLET TYPE, SPECIFY -X or -Z.

t Product Illustration follows.

49580A-LF SERIES Less Flange

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipatedand ultimate sanitation is desired, such as kitchens, hospitals and food processingplants. The 10-1/2" diameter grate and deep sump accept heavy flow and the domestrainer intercepts debris which could block the drain line. Double drainage flangeserves as an anchor in the sub-floor and redirects secondary moisture to the wasteline. It may also be used with a clamp device to assure a bond between the drain andthe flashing or waterproof membrane.

SPECIFICATIONJOSAM 49580A Series round cast iron 8" deep SUPER-FLO-SEPTOR® Floor Sink withacid-resisting interior, double drainage flange with weepholes, bottom outlet, alu-minum internal dome strainer, cast iron, non-traffic, acid-resisting, anti-tilting, SUPER-FLO® Grate.

49580A SERIES SUPER-FLO® 12” ROUND TOP, 8” DEEP

TYPE NO. PIPE SIZE LBS.49582A 2 4549583A 3 4649584A 4 47

TYPE NO. PIPE SIZE LBS.

49582A-LF 2 3749583A-LF 3 3849584A-LF 4 39

For Options, See Below

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipatedand ultimate sanitation is desired, such as kitchens, hospitals and food processingplants. The 10-1/2" diameter grate and deep sump accept heavy flow and the domestrainer intercepts debris which could block the drain line.

SPECIFICATIONJOSAM 49580A-LF Series round cast iron 8" deep SUPER-FLO-SEPTOR® Floor Sinkwith acid-resisting interior, bottom outlet, aluminum internal dome strainer, cast iron,non-traffic, acid-resisting, anti-tilting, SUPER-FLO® Grate.

t -LF Less Flanget -NB Nickel Bronze Traffic To

-LG Less Grate-3 1/2 Grate-4 3/4 Grate-7 Full Grate with 2-1/2” Center Opening-8 Depressed Grate, (Aluminum), NB-VP Secured Grate, Vandal-Proof Screws, NB-16 Grate with 4” Round Funnel-17 Grate with 6” Round Funne-18 Grate with 9” x 3-1/2” Oval Funnel-31 Sediment Bucket (Aluminum)-33 Sediment Bucket (A.R. Finish)

OPTIONSs -35 Stainless Steel Mesh Bucket Liner

-43 Internal Dome Strainer (A.R. Finish)-45 Less Internal Dome Strainer-51 Galvanized Cast Iron Inside and Outside-52 Painted Inside and Outside-55 1/2” Primer Adapter, 88450 Provided-C Clamp Device, 49580A, 49580A-NB

OUTLETS-X Inside Caulk Outlet-Z No-Hub Outlet

s Specify -31 or -33 Bucket

OPTIONS N/A: -VP, -C, -8

SLOT WIDTH 3/4”

SLOT WIDTH 3/4”

GRATE FREE AREA 19.7 SQ. IN.

FOR OUTLET TYPE, SPECIFY -X or -Z.

GRATE FREE AREA 19.7 SQ. IN.

OPTIONS N/A: -VP, -8

Floor Sinks_08.qxd 5/1/08 4:14 PM Page 178

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

179

FLOO

RSIN

KS

FOR OUTLET TYPE, SPECIFY -X or -Z.

FOR OUTLET TYPE, SPECIFY -X or -Z.

49580A-LF-NB SERIES Less Flange, with -NB Nikaloy Traffic Top

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipatedand ultimate sanitation is desired, such as kitchens, hospitals and food processingplants. The 11-1/8" diameter grate and deep sump accept heavy flow and the domestrainer intercepts debris which could block the drain line. Double drainage flangeserves as an anchor in the sub-floor and redirects secondary moisture to the wasteline. It may also be used with a clamp device to assure a bond between the drain andthe flashing or waterproof membrane.

SPECIFICATIONJOSAM 49580A-NB Series round cast iron 8-1/4" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, double drainage flange with weepholes, bottom out-let, aluminum internal dome strainer, Nikaloy sanitary sloped rim and Nikaloy, light-duty, anti-tilting, SUPER-FLO® Grate.

49580A-NB SERIES with -NB Nikaloy Traffic Top

TYPE NO. PIPE SIZE LBS.

49582A-NB 2 5049583A-NB 3 5149584A-NB 4 52

TYPE NO. PIPE SIZE LBS.

49582A-LF-NB 2 4349583A-LF-NB 3 4349584A-LF-NB 4 44

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipatedand ultimate sanitation is desired, such as kitchens, hospitals and food processingplants. The 11-1/8" diameter grate and deep sump accept heavy flow and the domestrainer intercepts debris which could block the drain line.

SPECIFICATIONJOSAM 49580A-LF-NB Series round cast iron 8-1/4" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, bottom outlet, aluminum internal dome strainer,Nikaloy sanitary sloped rim and Nikaloy, light-duty, anti-tilting, SUPER-FLO® Grate.

OPTION N/A: -C

SLOT WIDTH 1/2”

SLOT WIDTH 1/2”

GRATE FREE AREA 40 SQ. IN.

GRATE FREE AREA 40 SQ. IN.

Floor Sinks_08.qxd 3/27/08 9:58 AM Page 179

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

180

FLO

OR

SIN

KS

FOR OUTLET TYPE, SPECIFY -X.

FOR OUTLET TYPE, SPECIFY -X.

t Product Illustration follows.

49700-LF SERIES Less Flange

APPLICATIONFor use in non-traffic areas where space is limited such as under counters or againstwalls and ultimate sanitation is desired, such as kitchens, hospitals and food prepstations. The 3-3/8" x 7-3/8" rectangular grate and shallow sump accept light flowand the secondary strainer intercepts debris which could block the drain line. Doubledrainage flange serves as an anchor in the sub-floor and redirects secondary moistureto the waste line. It may also be used with a clamp device to assure a bond betweenthe drain and the flashing or waterproof membrane.

SPECIFICATIONJOSAM 49700 Series rectangular cast iron 3-1/2" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, double drainage flange with weepholes, bottom out-let, aluminum internal dome strainer and cast iron, non-traffic, acid-resisting grate.

49700 SERIES 4” X 8” RECTANGULAR TOP, 4’ DEEP

TYPE NO. PIPE SIZE LBS.49702 2 2449703 3 24

TYPE NO. PIPE SIZE LBS.49702-LF 2 1349703-LF 3 15

For Options, See Below

APPLICATIONFor use in non-traffic areas where space is limited such as under counters or againstwalls and ultimate sanitation is desired, such as kitchens, hospitals and food prepstations. The 3-3/8" x 7-3/8" rectangular grate and shallow sump accept light flowand the secondary strainer intercepts debris which could block the drain line.

SPECIFICATIONJOSAM 49700-LF Series rectangular cast iron 3-1/2" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, bottom outlet, aluminum internal dome strainer andcast iron, non-traffic, acid-resisting grate.

t -LF Less Flanget -NB Nickel Bronze Traffic Top

-LG Less Grate-3 1/2 Grate-4 3/4 Grate-7 Full Grate with 2-1/2” Center Opening-8 Depressed Grate, (Aluminum), NB-VP Secured Grate, Vandal-Proof Screws, NB-16 Grate with 4” Round Funnel-30 Stainless Steel Sediment Bucket-43 Internal Dome Strainer (A.R. Finish)-45 Less Internal Dome Strainer-51 Galvanized Cast Iron Inside and Outside

OPTIONS-52 Painted Inside and Outside-55 1/2” Primer Adapter, 88450 Provided-C Clamp Device, 49700, 49700-NB

OUTLETS-X Inside Caulk Outlet

OPTIONS N/A: -VP, -8

OPTIONS N/A: -VP, -C, -8

SLOT WIDTH 1/4”

SLOT WIDTH 1/4”

GRATE FREE AREA 7 SQ. IN.

GRATE FREE AREA 7 SQ. IN.

Floor Sinks_08.qxd 5/1/08 4:14 PM Page 180

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

181

FLOO

RSIN

KS

FOR OUTLET TYPE, SPECIFY -X.

FOR OUTLET TYPE, SPECIFY -X.

49700-LF-NB SERIES Less Flange, with -NB Nikaloy Traffic Top

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipated orspace is limited such as under counters or against walls and ultimate sanitation isdesired, such as kitchens, hospitals and food prep stations. The 3-3/8" x 7-3/8" rec-tangular grate and shallow sump accept light flow and the secondary strainer inter-cepts debris which could block the drain line. Double drainage flange serves as ananchor in the sub-floor and redirects secondary moisture to the waste line. It mayalso be used with a clamp device to assure a bond between the drain and the flash-ing or waterproof membrane.

SPECIFICATIONJOSAM 49700-NB Series rectangular cast iron 4" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, double drainage flange with weepholes, bottom out-let, aluminum internal dome strainer, Nikaloy rim and light-duty, anti-tilting, Nikaloygrate.

49700-NB SERIES with -NB Nikaloy Traffic Top

TYPE NO. PIPE SIZE LBS.

49702-NB 2 2649703-NB 3 26

TYPE NO. PIPE SIZE LBS.49702-LF-NB 2 1549703-LF-NB 3 18

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipated orspace is limited such as under counters or against walls and ultimate sanitation isdesired, such as kitchens, hospitals and food prep stations. The 3-3/8" x 7-3/8" rec-tangular grate and shallow sump accept light flow and the secondary strainer inter-cepts debris which could block the drain line.

SPECIFICATIONJOSAM 49700-LF-NB Series rectangular cast iron 4" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, bottom outlet, aluminum internal dome strainer,Nikaloy rim and light-duty, anti-tilting, Nikaloy grate.

OPTION N/A: -C

SLOT WIDTH 1/4”

SLOT WIDTH 1/4”

GRATE FREE AREA 10 SQ. IN.

GRATE FREE AREA 10 SQ. IN.

Floor Sinks_08.qxd 3/27/08 9:58 AM Page 181

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

182

FLO

OR

SIN

KS

FOR OUTLET TYPE, SPECIFY -X.

t Product Illustration follows.

49720-LF SERIES Less Flange

APPLICATIONFor use in non-traffic areas where space is limited such as under counters or againstwalls and ultimate sanitation is desired, such as kitchens, hospitals and food prepstations. The 5-5/8" x 11-3/8" rectangular grate and medium sump accept a moder-ate flow and the secondary strainer intercepts debris which could block the drain line.Double drainage flange serves as an anchor in the sub-floor and redirects secondarymoisture to the waste line. It may also be used with a clamp device to assure a bondbetween the drain and the flashing or waterproof membrane.

SPECIFICATIONJOSAM 49720 Series rectangular cast iron 6-1/2" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, double drainage flange with weepholes, bottom out-let, aluminum internal dome strainer and cast iron, non-traffic, acid-resisting grate.

49720 SERIES 6” X 12” RECTANGULAR TOP, 7” DEEP

TYPE NO. PIPE SIZE LBS.49723 3 4949724 4 4949726 6 50

TYPE NO. PIPE SIZE LBS.

For Options, See Below

APPLICATIONFor use in non-traffic areas where space is limited such as under counters or againstwalls and ultimate sanitation is desired, such as kitchens, hospitals and food prepstations. The 5-5/8" x 11-3/8" rectangular grate and medium sump accept a moder-ate flow and the secondary strainer intercepts debris which could block the drain line.

SPECIFICATIONJOSAM 49720-LF Series rectangular cast iron 6-1/2" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, bottom outlet, aluminum internal dome strainer andcast iron, non-traffic, acid-resisting grate.

t -LF Less Flanget -NB Nickel Bronze Traffic Top

-LG Less Grate-3 1/2 Grate-4 3/4 Grate-7 Full Grate with 2-1/2” Center Opening-8 Depressed Grate, (Aluminum), NB-VP Secured Grate, Vandal-Proof Screws, NB-16 Grate with 4” Round Funnl-18 Grate with 9” x 3-1/2” Oval Funnel-30 Stainless Steel Sediment Bucket-43 Internal Dome Strainer (A.R. Finish)-45 Less Internal Dome Strainer

OPTIONS-51 Galvanized Cast Iron Inside and Outside-52 Painted Inside and Outside-55 1/2” Primer Adapter, 88450 Provided for 3", 4"

1/2" Primer Tap, 6"-C Clamp Device, 49720, 49720-NB

OUTLET-X Inside Caulk Outlet

OPTIONS N/A: -VP, -C, -8

SLOT WIDTH 3/8”

SLOT WIDTH 3/8”

GRATE FREE AREA 22 SQ. IN.

FOR OUTLET TYPE, SPECIFY -X.

GRATE FREE AREA 22 SQ. IN.

49723-LF 3 3649724-LF 4 3549726-LF 6 40

OPTIONS N/A: -VP, -8

Floor Sinks_08.qxd 5/2/08 12:50 PM Page 182

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

183

FLOO

RSIN

KS

FOR OUTLET TYPE, SPECIFY -X.

FOR OUTLET TYPE, SPECIFY -X.

49720-LF-NB SERIES Less Flange, with -NB Nikaloy Traffic Top

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipated orspace is limited such as under counters or against walls and ultimate sanitation isdesired, such as kitchens, hospitals and food prep stations. The 5-5/8" x 11-3/8" rec-tangular grate and medium sump accept a moderate flow and the secondary strainerintercepts debris which could block the drain line. Double drainage flange serves asan anchor in the sub-floor and redirects secondary moisture to the waste line. It mayalso be used with a clamp device to assure a bond between the drain and the flash-ing or waterproof membrane.

SPECIFICATIONJOSAM 49720-NB Series rectangular cast iron 7" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, double drainage flange with weepholes, bottom out-let, aluminum internal dome strainer, Nikaloy rim and light-duty, anti-tilting, Nikaloygrate.

49720-NB SERIES with -NB Nikaloy Traffic Top

TYPE NO. PIPE SIZE LBS.

49723-NB 3 5249724-NB 4 5349726-NB 6 54

TYPE NO. PIPE SIZE LBS.

49723-LF-NB 3 3949724-LF-NB 4 3849726-LF-NB 6 43

APPLICATIONFor use in areas where pedestrian and medium weight wheel loads are anticipated orspace is limited such as under counters or against walls and ultimate sanitation isdesired, such as kitchens, hospitals and food prep stations. The 5-5/8" x 11-3/8" rec-tangular grate and medium sump accept a moderate flow and the secondary strainerintercepts debris which could block the drain line.

SPECIFICATIONJOSAM 49720-LF-NB Series rectangular cast iron 7" deep SUPER-FLO-SEPTOR® FloorSink with acid-resisting interior, bottom outlet, aluminum internal dome strainer,Nikaloy rim and light-duty, anti-tilting, Nikaloy grate.

OPTION N/A: -C

SLOT WIDTH 1/4”

SLOT WIDTH 1/4”

GRATE FREE AREA 25 SQ. IN.

GRATE FREE AREA 25 SQ. IN.

Floor Sinks_08.qxd 3/27/08 9:58 AM Page 183

SANITARY FLOOR SINKSSANITARY FLOOR SINKS

184

FLO

OR

SIN

KS

49870A SERIES CAN WASH DRAIN, 12” SQUARE TOP, 8” DEEP

APPLICATIONFor use in pedestrian traffic areas requiring a high degree of sanitation where solid wastemay be present, such as hospital operating rooms, cystoscopic rooms, prison holding cellsand animal research or other labs where undesirable materials can be flushed to thesewer. The flushing connection and flushing rim facilitate thorough cleaning with eachflush. The white acid-resisting coated interior assures ease of sanitary maintenance.

SPECIFICATIONJOSAM 49850 Series round cast iron Floor Sink with acid-resisting interior, doubledrainage flange with weepholes, bottom outlet, inside caulk connection, flushing connec-tions, bronze flushing rim, and Nikaloy round top with light-duty perforated hinged grate.

49850 SERIES FLUSHING RIM, 12” ROUND TOP

TYPE NO. PIPE SIZE LBS.

49852* 2 4249853* 3 4249854 4 44

49856-Z 6 44

TYPE NO. PIPE SIZE LBS.

49873A 3 5949874A 4 59

TYPE NO. PIPE SIZE LBS.

APPLICATIONFor use in areas where it is desired to wash the interior of garbage and other canssuch as in commercial kitchens. The bronze spray nozzle cleanses the inside of thecan and the grate and bucket prevent solids from entering the waste line. The whiteacid-resisting coated interior assures ease of sanitary maintenance.

SPECIFICATIONJOSAM 49870A Series square cast iron SUPER-FLO-SEPTOR® Can Wash Drain withacid-resisting interior, double drainage flange with weepholes, bottom outlet, remov-able sediment bucket, bronze spray nozzle assembly, Nikaloy rim and light-duty,Nikaloy, secured grate.

SLOT WIDTH 3/8”

-VP Secured Grate, Vandal-Proof Screws-13 One-Piece Satin Nikaloy Grate-14 Loose-Set Satin Nikaloy Grate-51 Galvanized Cast Iron Inside and Outside-98 Water Supply Control Box-C Clamp Device

OUTLETS-X Inside Caulk Outlet, 2"- 4"-Z No-Hub Spigot Outlet, 6”

-VP Secured Grate, Vandal-Proof Screws-35 Stainless Steel Mesh Bucket Liner-51 Galvanized Cast Iron Inside and Outside-55 1/2” Primer Adapter, 88450 Provided-98 Water Supply Control Box-C Clamp Device

OUTLETS-X Inside Caulk Outlet-Z No-Hub Spigot Outlet

Options

Options

GRATE FREE AREA 35 SQ. IN.

FOR OUTLET TYPE, SPECIFY -X or -Z.

FOR OUTLET TYPE, SPECIFY -X.

Vacuum breaker should be installed subject to local code requirements.*49852 & 49853 use a 49854 Body with a Reducing Coupling

Vacuum breaker should be installed subject to local code requirements.

Floor Sinks_08.qxd 5/1/08 2:41 PM Page 184

185

CLEANOUT FEATURESCLEANOUT FEATURESCLEA

NO

UTS

KLEENATRON® II Features

JOSAM KLEENATRON® II Cleanouts incorporate features developed to meetthe latest in building construction methods. These features ensure the specifier,installer and user of completely trouble-free installation and performance.

WIDE CHOICE OF COVERSTops and covers for every area.Round-square, tile-terrazzo,medium-special-duty. Standardcast iron secured cover has special-duty rating.*

ADJUSTABLE BUSHINGPrecision machine threaded castiron bushing provides LEVELEZE®

adjustment; non-tilting top. Bodyprotects threads from concrete,allowing adjustment after pour.

EASY IN – EASY OUT CLOSURE PLUGABS plastic closure plug withgas-tight sealing tapered threads.

*SPECIAL-DUTY: Grates testing over10,000 lb. (4500 kg.) ASME 112.6.3-2001.

55000

OPTIONAL (-F) FLASHING FLANGEMates with machined exterior thread onferrule to provide watertight connectionwithout the additional use of sealant byothers.

OPTIONAL CLAMP RINGTo secure waterproof membraneto flashing flange.

55000-Y Series KLEENATRON®

Cleanouts feature JOSAM JIFFEE-SET connections withMULTI-TITE® service weight (SV)soil pipe gaskets in 2, 3 and 4 inch sizes for labor-savingassembly to service weight andno-hub cast iron pipe, and to PVCand ABS pipe. Merely lubricategasket and pipe, set cleanout inplace, push down until top of pipecontacts built-in stop and the joint is complete.

CAST IRON BODYWith interior threads to provideunimpaired LEVELEZE® adjustmentof top section.

Cleanouts_08.qxd 3/27/08 10:53 AM Page 185

58631 -CO3 -20 -VP

Type No. for 8” x 8” CoverNo-Hub Cleanout, 3”Raised Head Bronze PlugSecured Cover, Vandal-Proof Screws

55004 -Z -1 -VP -22

Outlet SizeOutlet Type, No Hub OutletOptional Material, Satin Finish Nikaloy TopOption, Secured Cover, Vandal-Proof ScrewsOption, Taper Thread Bronze Plug

186

CLEANOUTS CLEANOUTSCL

EAN

OU

TS

FLOOR CLEANOUTS – Unless optional materials are specified, standard material shown in Specification will be provided.

Example: Series No. 55000 Type No. 55004

WALL 0R FLOOR ACCESS COVERS – When outlet size does not apply, refer to dimension table for Type No. to be ordered.

How to Order

Example: Series No. 58630 Type No. 58631

CLEANOUTS • Pictorial Selection GuideCLEANOUTS • Pictorial Selection Guide

ADJUSTABLE FLOOR CLEANOUTS55000C.I. Cover, Internal Plug

Page 188

55000-1Nikaloy Cover, Internal Plug

Page 188

55000-1-SDNikaloy Laminated C.I. Cover, Internal Plug

Page 189

55000-1-SQNikaloy Cover, Internal Plug

Page 190

55000-1-13Nikaloy Cover Recessed forTerrazzo Tile, Internal Plug

Page 191

57008-Z-CICast Iron Cover,Internal Plug

Page 192

ADJUSTABLE FLOOR CLEANOUTS57008-Z-1Nikaloy Cover, Internal Plug

Page 192

57008-Z-1-SDNikaloy Laminated C.I. Cover, Internal Plug

Page 192

57008-Z-1-12Nikaloy Cover Recessed for Tile, Internal Plug

Page 193

57008-Z-LTNo-Hub Cast Iron Ferrule & ABS Plug

Page 193

58360Nikaloy Cover, Bronze Plug

Page 194

58460ANikaloy Cover, Bronze Plug,Double Drainage Flange

Page 194

Cleanouts_08.qxd 3/27/08 10:53 AM Page 186

CLEANOUTS • Pictorial Selection GuideCLEANOUTS • Pictorial Selection Guide

187

CLEAN

OU

TS

ADJ. C.O. ACCESS HOUSINGS SPANNER58460A-AENikaloy Cover, Bronze Plug,Adjustable Collar

Page 195

58580Cast Iron Access Housing

Page 196

58580-1Nikaloy Access Housing

Page 196

58580-1-SQNikaloy Access Housing

Page 197

58680Heavy-Duty Access Housing

Page 201

56670Threaded Cover,Spanner Type

Page 191

PLUG FERRULE C.O. TEE ACCESS COVERS58540N.P.T. Threaded Bronze Plug

Page 195

58900No-Hub Ferrule,Bronze Plug

Page 203

58910No-Hub Cleanout Tee,Bronze Plug

Page 204

58600Access Cover

Page 198

58610Access Cover with Anchor Lugs

Page 198

58620Hinged Access Cover

Page 199

ACCESS COVERS COMBINATIONS58630Hinged Access Cover

Page 199

58640Secured Cover

Page 200

58650Secured Cover

Page 200

58600-PLGAccess Cover & Plug

Page 201

58600-COAccess Cover and No-Hub Cleanout

Page 201

58600-COTAccess Cover and No-Hub Cleanout Tee

Page 202

COMBINATIONS58610-COAccess Cover with AnchorLugs & No-Hub Cleanout

Page 201

58610-COTAccess Cover with AnchorLugs & No-Hub Cleanout Tee

Page 201

58630-COHinged Access Cover and No-Hub Cleanout

Page 202

58630-COTHinged Access Cover and No-Hub Cleanout Tee

Page 202

58640-COSecured Cover and No-Hub Cleanout

Page 203

58640-COTSecured Cover and No-Hub Cleanout Tee

Page 203

Cleanouts_08.qxd 3/27/08 10:54 AM Page 187

APPLICATIONFor use in finished floors subject to pedestrian and light wheel traffic such as schools,hospitals and shopping malls. Top design allows for unimpaired adjustment even asthe floor is being poured.

SPECIFICATIONJOSAM 55000-1 Series coated cast iron LEVELEZE® KLEENATRON® II Floor Cleanout,internal ABS cleanout plug, adjustable cast iron housing with medium-duty scoriatedsecured round satin Nikaloy cover.

APPLICATIONFor use in finished or unfinished floors subject to heavy wheel traffic such as ware-houses, loading docks and warehouse stores. Top design allows for unimpairedadjustment even as the floor is being poured.

SPECIFICATIONJOSAM 55000 Series coated cast iron LEVELEZE® KLEENATRON® II Floor Cleanout,internal ABS cleanout plug, adjustable cast iron housing with special-duty scoriatedsecured round cast iron cover.

CLEANOUTSCLEANOUTS

188

CLEA

NO

UTS

t -1 Satin Finish Nikaloy Topt -1-SD Special-Duty Satin Finish

Nikaloy Topt -1-SQ Square Top,

Satin Finish Nikaloyt -1-12 Cover Recessed for Tile,

Satin Finish Nikaloyt -1-13 Terrazzo Tile Cover,

Satin Finish Nikaloy-2 Satin Finish Bronze Top-2-SD Special-Duty Satin Finish

Bronze Top-2-SQ Square Top,

Satin Finish Bronze-2-12 Cover Recessed for Tile,

Satin Finish Bronze-2-13 Terrazzo Tile Cover,

Satin Finish Bronze-SS Stainless Steel Top

-SS-SQ Square Top, Stainless Steelt -5 Ductile Iron Top

-14 Carpet Cleanout Marker-VP Secured Cover,

Vandal-Proof Screws-22 Taper Thread Bronze Plug-31 Galvanized Cast Iron Parts-41 Clamp Ring and Flange-F Flange Only-WF Wide Flange

(not available on Cl)-CFC Carpet Cleanout Flange

CoverOUTLETS:

-X Inside Caulk Outlet-Y Hub Outlet w/Gasket, 2”-4”-Z No-Hub Outlet

Available Options

FOR OUTLET TYPE SPECIFY -X, -Y or -ZTYPE NO. PIPE SIZE A B C* D X Y LBS.55002-1 2 5-1/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 1255003-1 3 5-1/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 1255004-1 4 5-1/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 1355004-1-X 4 6-5/8 4-1/4 9-3/16 7 2 3-11/16 1455005-1-Z 5 5-1/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 1255006-1-Z 6 6-5/8 4-1/4 9-3/16 7 2 3-11/16 14

B

XY

PIPE SIZE

C

D

A

OPTIONAL (-41)CLAMP RING

OPTIONAL (-F)FLANGE

ADJUSTABLE CAST IRONBUSHING

THREADEDABS PLUG

- MIN- MAX

FOR OUTLET TYPE SPECIFY -X, -Y or -ZTYPE NO. PIPE SIZE A B C* D X Y LBS.55002 2 6 3-3/4 7-1/2 5-9/16 2-3/4 4-1/4 1555003 3 6 3-3/4 7-1/2 5-9/16 2-3/4 4-1/4 1555004 4 6 3-3/4 7-1/2 5-9/16 2-3/4 4-1/4 1655004-X 4 7-1/2 4-1/4 9-3/16 7 2-5/8 4-5/16 1855005-Z 5 6 3-3/4 7-1/2 5-9/16 2-3/4 4-1/4 1655006-Z 6 7-1/2 4-1/4 9-3/16 7 2-5/8 4-5/16 18

* FLANGE STANDARD ON 4” -X AND 6” SIZES.

* FLANGE STANDARD ON 4” -X AND 6” SIZES.

B

XY

PIPE SIZE

C

D

A

OPTIONAL (-41)CLAMP RING

OPTIONAL (-F)FLANGE

ADJUSTABLE CAST IRONBUSHING

THREADEDABS PLUG

- MIN- MAX

55000-1 SERIES with -1 Nikaloy Top

55000 SERIES LEVELEZE® KLEENATRON® II SPECIAL-DUTY

t Product Illustration follows.

Cleanouts_08.qxd 5/1/08 3:02 PM Page 188

B

XY

PIPE SIZE

C

D

A

OPTIONAL (-41)CLAMP RING

OPTIONAL (-F)FLANGE

ADJUSTABLE CAST IRONBUSHING

THREADEDABS PLUG

- MIN- MAX

CLEANOUTSCLEANOUTS

189

CLEAN

OU

TS

APPLICATIONFor use in finished or unfinished floors subject to heavy wheel traffic or impact loads,such as warehouses, loading docks and warehouse stores. Top design allows forunimpaired adjustment even as the floor is being poured.

SPECIFICATIONJOSAM 55000-5 Series coated cast iron LEVELEZE® KLEENATRON® II Floor Cleanout,internal ABS cleanout plug, adjustable cast iron housing with special-duty scoriatedsecured round ductile iron cover.

OPTION N/A:-WF

FOR OUTLET TYPE SPECIFY -X, -Y or -ZTYPE NO. PIPE SIZE A B C* D X Y LBS.55002-5 2 6 3-3/4 7-1/2 5-9/16 2-3/4 4-1/4 1555003-5 3 6 3-3/4 7-1/2 5-9/16 2-3/4 4-1/4 1555004-5 4 6 3-3/4 7-1/2 5-9/16 2-3/4 4-1/4 1655004-5-X 4 7-1/2 4-1/4 9-3/16 7 2-5/8 4-5/16 1855005-5-Z 5 6 3-3/4 7-1/2 5-9/16 2-3/4 4-1/4 1655006-5-Z 6 7-1/2 4-1/4 9-3/16 7 2-5/8 4-5/16 18

* FLANGE STANDARD ON 4” -X AND 6” SIZES.

FOR OUTLET TYPE SPECIFY -X, -Y or -ZTYPE NO. PIPE SIZE A B C* D X Y LBS.55002-1-SD 2 6-9/16 3-3/4 7-1/2 5-9/16 3 4-1/2 1655003-1-SD 3 6-9/16 3-3/4 7-1/2 5-9/16 3 4-1/2 1655004-1-SD 4 6-9/16 3-3/4 7-1/2 5-9/16 3 4-1/2 1755004-1-SD-X 4 8-3/16 4-1/4 9-3/16 7 2-7/8 4-9/16 1955005-1-SD-Z 5 6-9/16 3-3/4 7-1/2 5-9/16 3 4-1/2 1755006-1-SD-Z 6 8-3/16 4-1/4 9-3/16 7 2-7/8 4-9/16 19

* FLANGE STANDARD ON 4” -X AND 6” SIZES.

APPLICATIONFor use in finished or unfinished floors subject to heavy wheel traffic or impact loads,such as warehouses, loading docks and warehouse stores. Top design allows forunimpaired adjustment even as the floor is being poured.

SPECIFICATIONJOSAM 55000-1-SD Series coated cast iron LEVELEZE® KLEENATRON® II Floor Cleanout,internal ABS cleanout plug, adjustable cast iron housing with special-duty scoriatedsecured round laminated satin Nikaloy cover.

B

XY

PIPE SIZE

C

D

A

OPTIONAL (-41)CLAMP RING

OPTIONAL (-F)FLANGE

ADJUSTABLE CAST IRONBUSHING

THREADEDABS PLUG

- MIN- MAX

55000-1-SD SERIES with -1-SD Nikaloy Special-Duty Top

55000-5 SERIES with -5 Ductile Iron Top

Cleanouts_08.qxd 5/1/08 3:02 PM Page 189

APPLICATIONFor use in finished floors subject to pedestrian and light wheel traffic such as schools,hospitals and shopping malls where a square top complements construction or floorfinish. Top design allows for unimpaired adjustment even as the floor is being poured.

SPECIFICATIONJOSAM 55000-1-SQ Series coated cast iron LEVELEZE® KLEENATRON® II Floor Cleanout,internal ABS cleanout plug, adjustable cast iron housing with medium-duty scoriatedsecured square satin Nikaloy cover.

OPTION N/A:-WF

APPLICATIONFor use in finished floors subject to pedestrian and light wheel traffic such as schools,hospitals and shopping malls where the recessed cover accepts matching tile to com-plement floor finish. Top design allows for unimpaired adjustment even as the floor isbeing poured.

SPECIFICATIONJOSAM 55000-1-12 Series coated cast iron LEVELEZE® KLEENATRON® II Floor Cleanout,internal ABS cleanout plug, adjustable cast iron housing with medium-duty scoriatedsecured round satin Nikaloy cover recessed for tile.

CLEANOUTSCLEANOUTS

190

CLEA

NO

UTS

55000-1-SQ SERIES with -1-SQ Nikaloy Square Top

55000-1-12 SERIES with -1-12 Nikaloy Top Recessed for Tile

FOR OUTLET TYPE SPECIFY -X, -Y or -ZTYPE NO. PIPE SIZE A B C* D X Y LBS.55002-1-SQ 2 5-3/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 1355003-1-SQ 3 5-3/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 1355004-1-SQ 4 5-3/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 1455004-1-SQ-X 4 7 4-1/4 9-3/16 7 2 3-11/16 1655005-1-SQ-Z 5 5-3/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 1455006-1-SQ-Z 6 7 4-1/4 9-3/16 7 2 3-11/16 16

* FLANGE STANDARD ON 4” -X AND 6” SIZES.

FOR OUTLET TYPE SPECIFY -X, -Y or -ZTYPE NO. PIPE SIZE A B C* D X Y LBS.55002-1-12 2 5-1/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 1255003-1-12 3 5-1/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 1255004-1-12 4 5-1/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 1355004-1-12-X 4 6-5/8 4-1/4 9-3/16 7 2 3-11/16 1455005-1-12-Z 5 5-1/8 3-3/4 7-1/2 5-9/16 2-1/8 3-5/8 1255006-1-12-Z 6 6-5/8 4-1/4 9-3/16 7 2 3-11/16 14

* FLANGE STANDARD ON 4” -X AND 6” SIZES.

B

XY

PIPE SIZE

C

D

A SQ.

OPTIONAL (-41)CLAMP RING

OPTIONAL (-F)FLANGE

ADJUSTABLE CAST IRONBUSHING

THREADEDABS PLUG

- MIN- MAX

B

PIPE SIZE

C

D

A

XY

OPTIONAL (-41)CLAMP RING

OPTIONAL (-F)FLANGE

ADJUSTABLE CAST IRONBUSHING

THREADEDABS PLUG

- MIN- MAX

COVER RECESSED FOR TILE

Cleanouts_08.qxd 5/1/08 3:02 PM Page 190

APPLICATIONFor use in finished floors subject to pedestrian and light wheel traffic such as schools,hospitals and shopping malls where the recessed cover accepts terrazzo flooring. Topdesign allows for unimpaired adjustment even as the floor is being poured.

SPECIFICATIONJOSAM 55000-1-13 Series coated cast iron LEVELEZE® KLEENATRON® II Floor Cleanout,internal ABS cleanout plug, adjustable cast iron housing with medium-duty scoriatedsecured round satin Nikaloy cover recessed for terrazzo flooring.

OPTION N/A:-WF

APPLICATIONFor use in finished floors subject to pedestrian or light wheel traffic where directaccess to drain or waste line is desired. A threaded flanged plug maintains the gasand watertight seal and is removable by the use of a spanner wrench.

SPECIFICATIONJOSAM 56670 Series round cast Nikaloy Floor Cleanout, inside caulk connection, andthreaded satin scoriated round cover with spanner wrench sockets.

CLEANOUTSCLEANOUTS

191

CLEAN

OU

TS

55000-1-13 SERIES with -1-13 Terrazzo Tile Cover

56670 SERIES SPANNER TYPE FLOOR CLEANOUT

-2 Satin Finish Bronze Top-11 Smooth Top-14 Carpet Cleanout Marker-24 Spanner Wrench

OUTLET:-X Inside Caulk Outlet

FOR OUTLET TYPE SPECIFY -X, -Y or -ZTYPE NO. PIPE SIZE A B C* D X Y LBS.55002-1-13 2 5-1/4 3-3/4 7-1/2 5-9/16 2-7/8 4-3/8 1555003-1-13 3 5-1/4 3-3/4 7-1/2 5-9/16 2-7/8 4-3/8 1555004-1-13 4 5-1/4 3-3/4 7-1/2 5-9/16 2-7/8 4-3/8 1655004-1-13-X 4 7 4-1/4 9-3/16 7 2-3/4 4-7/16 1855005-1-13-Z 5 5-1/4 3-3/4 7-1/2 5-9/16 2-7/8 4-3/8 1655006-1-13-Z 6 7 4-1/4 9-3/16 7 2-3/4 4-7/16 18

* FLANGE STANDARD ON 4” -X AND 6” SIZES.

FOR OUTLET TYPE SPECIFY -XTYPE NO. PIPE SIZE B C E LBS.56672 2 3-3/8 5-3/8 3-1/4 356673 3 5-1/2 7-3/8 3-1/4 656674 4 5-1/2 7-3/8 3-1/4 656675 5 7-3/4 9-3/8 3-1/2 956676 6 7-3/4 9-1/2 3-5/8 10

Available Options

B

PIPE SIZE

C

D

A

XY OPTIONAL (-41)

CLAMP RING

OPTIONAL (-F)FLANGE

ADJUSTABLE CAST IRONBUSHING

THREADEDABS PLUG

- MIN- MAX

Cleanouts_08.qxd 5/2/08 12:58 PM Page 191

APPLICATIONFor use in finished or unfinished floors subject to heavy wheel traffic such as ware-houses, loading docks and warehouse stores. Top design allows for unimpairedadjustment even as the floor is being poured.

SPECIFICATIONJOSAM 57008-Z-CI Series coated cast iron LEVELEZE® KLEENATRON® Floor Cleanout,internal gasketed ABS cleanout plug and adjustable ABS housing with special-dutyscoriated secured round cast iron top.

CLEANOUTSCLEANOUTS

192

CLEA

NO

UTS

57008-Z-CI SERIES LEVELEZE® KLEENATRON®

57008-Z-1 SERIES with -1 Nikaloy Top

57008-Z-1-SD SERIES with -1-SD Special-Duty Nikaloy Top

Available Optionst -1 Satin Finish Nikaloy Topt -1-SD Special-Duty SF Nikaloy Topt -1-SQ Square Top, SF Nikaloyt -1-12 Cover Recessed for Tile,

Satin Finish Nikaloy-2 Satin Finish Bronze Top-2-SD Special-Duty SF Bronze Top-2-SQ Square Top, SF Bronze-2-12 Cover Recessed for Tile,

Satin Finish Bronze

-14 Carpet Cleanout Marker-VP Secured Cover, VP Screws-22 Taper Thread Bronze Plug-31 Galvanized Cast Iron Parts-WF Wide Flange (N/A on C.I.)-CFC Carpet Cleanout Flange Cover

OUTLET:-Z No-Hub Outlet

FOR OUTLET TYPE SPECIFY -ZTYPE NO. PIPE SIZE LBS.57008-Z-CI 8 25

FOR OUTLET TYPE SPECIFY -ZTYPE NO. PIPE SIZE LBS.57008-Z-1 8 18

FOR OUTLET TYPE SPECIFY -ZTYPE NO. PIPE SIZE LBS.

57008-Z-1-SD 8 31

APPLICATIONFor use in finished floors subject to pedestrian and light wheel traffic such as schools,hospitals and shopping malls. Top design allows for unimpaired adjustment even asthe floor is being poured.

SPECIFICATIONJOSAM 57008-Z-1 Series coated cast iron LEVELEZE® KLEENATRON® Floor Cleanout,internal gasketed ABS cleanout plug, no-hub connection, and adjustable ABS housingwith medium-duty scoriated secured round satin Nikaloy top.

APPLICATIONFor use in finished or unfinished floors subject to heavy wheel traffic such as ware-houses, loading docks and warehouse stores. Top design allows for unimpairedadjustment even as the floor is being poured.

SPECIFICATIONJOSAM 57000-Z-1-SD Series coated cast iron LEVELEZE® KLEENATRON® FloorCleanout, internal gasketed ABS cleanout plug, no-hub connection and adjustableABS housing with special-duty scoriated secured round laminated satin Nikaloy top.

OPTION N/A-SQ

t Product Illustration follows.

Cleanouts_08.qxd 3/27/08 10:54 AM Page 192

CLEANOUTSCLEANOUTS

193

CLEAN

OU

TS

57008-Z-1-SQ SERIES with -1-SQ Nikaloy Square Top

57008-Z-1-12 SERIES with -1-12 Nikaloy Top Recessed for Tile

57008-Z-LT SERIES with -LT Less Top

APPLICATIONFor use in finished floors subject to pedestrian and light wheel traffic such as schools,hospitals and shopping malls where a square top complements construction or floorfinish. Top design allows for unimpaired adjustment even as the floor is being poured.

SPECIFICATIONJOSAM 57008-Z-1-SQ Series coated cast iron LEVELEZE® KLEENATRON® FloorCleanout, internal gasketed ABS cleanout plug, no-hub connection, and adjustableABS housing with medium-duty scoriated secured square satin Nikaloy top.

APPLICATIONFor use in finished floors subject to pedestrian and light wheel traffic such as schools,hospitals and shopping malls. Top design allows for unimpaired adjustment even asthe floor is being poured.

SPECIFICATIONJOSAM 57008-Z-1-12 Series coated cast iron LEVELEZE® KLEENATRON® FloorCleanout, internal gasketed ABS cleanout plug, no-hub connection, and adjustableABS housing with medium-duty scoriated secured round satin Nikaloy cover recessedfor tile.

APPLICATIONFor use in unfinished areas not subject to traffic.

SPECIFICATIONJOSAM 57008-Z-LT Series coated cast iron Cleanout Ferrule, no-hub connection andgasketed ABS cleanout plug.

FOR OUTLET TYPE SPECIFY -ZTYPE NO. PIPE SIZE LBS.

57008-Z-1-SQ 8 19

FOR OUTLET TYPE SPECIFY -ZTYPE NO. PIPE SIZE LBS.

57008-Z-1-12 8 19

FOR OUTLET TYPE SPECIFY -ZTYPE NO. PIPE SIZE LBS.57008-Z-LT 8 11

Cleanouts_08.qxd 3/27/08 10:54 AM Page 193

CLEANOUTSCLEANOUTS

194

CLEA

NO

UTS

FOR OUTLET TYPE SPECIFY -Y or -ZTYPE NO. PIPE SIZE A B C D LBS.58362 2 2 1-1/2 4 4-1/2 458363 3 2 1-1/2 4 3-1/8 458364 4 3 2-3/4 5 3-3/8 658365 5 3 2-3/4 5 4-1/4 1258366 6 3 2-3/4 5 4-1/4 1358362-Y 2 2 1-1/2 4 3-1/8 458363-Y 3 3 2-3/4 5 3-3/8 658364-Y 4 3 2-3/4 5 4-1/4 12

APPLICATIONFor use in finished floors subject to pedestrian and light wheel traffic such as stripmalls and light commercial buildings where a full line sized plug is not required. Topdesign allows for adjustment.

SPECIFICATIONJOSAM 58360 Series coated cast iron Ferrule and adjustable cast Nikaloy FloorCleanout, internal bronze countersunk plug and solid scoriated secured round cover.

APPLICATIONFor use in unfinished floors subject to pedestrian and light wheel traffic such asschools, hospitals and shopping malls where an oversized cover and body aredesired. Top assembly has double drainage flange with flashing clamp.

SPECIFICATIONJOSAM 58460A Series coated cast iron Floor Cleanout, internal bronze countersunkplug, inside caulk connection, and scoriated round top.

58360 SERIES ADJUSTABLE FLOOR CLEANOUT

58460A SERIES FLOOR CLEANOUT

-2 Satin Finish Bronze Top-14 Carpet Cleanout Marker-VP Secured Cover, Vandal-Proof Screws-31 Galvanized Cast Iron Parts

OUTLETS:-Y Hub Outlet w/Gasket, 2”-4”-Z No-Hub Spigot Outlet

Available Options

Available Optionst -AE Adjustable Extension

-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-6 Square Top, Cast Iron-6-1 Square Top, Nikaloy-6-2 Square Top, Bronze-12 Top Recessed for Tile-14 Carpet Cleanout Marker-VP Secured Cover, Vandal-Proof Screws-20 Raised Head Bronze Plug-31 Galvanized Cast Iron Parts

OUTLET:-X Inside Caulk Outlet

FOR OUTLET TYPE SPECIFY -XTYPE NO. PIPE SIZE D LBS.58462A 2 4 2658463A 3 4 2658464A 4 5 29

ss ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

CONFORMS WITH ASTM-C564.

t Product Illustration follows.

Cleanouts_08.qxd 3/27/08 10:54 AM Page 194

CLEANOUTSCLEANOUTS

195

CLEAN

OU

TS

APPLICATIONFor use in finished floors subject to pedestrian and light wheel traffic such as schools,hospitals and shopping malls where an oversized cover and body are desired. Topdesign allows for adjustment even as the floor is being poured.

SPECIFICATIONJOSAM 58460A-AE Series coated cast iron LEVELEZE® Floor Cleanout, adjustable col-lar with rolled thread and internal bronze countersunk plug, inside caulk connection,satin Nikaloy rim and scoriated secured round Nikaloy cover.

58460A-AE SERIES with -AE Adjustable Extension

58540 SERIES THREADED BRONZE PLUGAPPLICATION

For use as a replacement plug for JOSAM cleanouts or any N.P.T. female threaded fitting.

SPECIFICATIONJOSAM 58540 Series countersunk bronze N.P.T. Threaded Plug for use in conjunctionwith JOSAM cleanouts or standard pipe fittings.

FOR OUTLET TYPE SPECIFY -XTYPE NO. PIPE SIZE D LBS.

58462A-AE 2 3 3858463A-AE 3 4 3858464A-AE 4 5 38

TYPE NO. PIPE SIZE B C LBS. B (-20) C (-20) LBS. (-20)58541 1 7/8 1/2 1 7/16 3/8 158541-1/4 1-1/4 7/8 1/2 1 1/2 5/8 158541-1/2 1-1/2 5/8 3/8 1 5/8 3/4 158542 2 5/8 3/8 1 5/8 3/4 158542-1/2 2-1/2 3/4 1/2 1 3/4 3/4 158543 3 3/4 1/2 1 3/4 1 158543-1/2 3-1/2 3/4 1/2 1 3/4 1 158544 4 7/8 1/2 1 7/8 1 258545 5 1 1/2 2 1 1 358546 6 1 1/2 3 1 1 558548 8 1-1/8 5/8 7 1-1/8 1-1/8 8

s58549 10 – – – 1-1/8 1-1/4 10

* THIS DIM. 9" SQ. ON (-6) TOP.

Available Options-19 Plug Tapped for Center Screw-20 Raised Head Bronze Plug

s For 10” Size, Specify 58549-20s 10” Size Available with Raised Head Plug Only

Cleanouts_08.qxd 5/1/08 3:02 PM Page 195

CLEANOUTSCLEANOUTS

196

CLEA

NO

UTS

APPLICATIONFor use in finished or unfinished floors subject to heavy wheel traffic such as ware-houses, loading docks and warehouse stores. May be used with cast iron or plasticcleanout ferrule and plug supplied by others. LEVELOC® thumb screws allow top to besecured to ferrule.

SPECIFICATIONJOSAM 58580 Series ABS Floor Access Housing with special-duty scoriated securedround cast iron top and LEVELOC® screws.

58580 SERIES ACCESS HOUSING AND COVER

58580-1 SERIES with -1 Nikaloy Top

t -1 Satin Finish Nikaloy Topt -1-SD Special-Duty Satin Finish Nikaloy Topt -1-SQ Square Top, Satin Finish Nikaloy

-2 Satin Finish Bronze Top-2-SD Special-Duty Satin Finish Bronze Top-2-SQ Square Top, Satin Finish Bronze-5 Ductile Iron Top

APPLICATIONFor use in finished floors subject to pedestrian and light wheel traffic such as schools,hospitals and shopping malls. May be used with cast iron or plastic cleanout ferrule andplug supplied by others. LEVELOC® thumb-screws allow top to be secured to ferrule.

SPECIFICATIONJOSAM 58580-1 Series ABS Floor Access Housing with scoriated secured round satinNikaloy top and LEVELOC® screws.

Available Options

q MAXIMUM SPACE AVAILABLE FOR PIPE FITTING ENCLOSURE, ETC.TYPE NO. PIPE SIZE A q B C D LBS.58582 2 6 3-3/16 3-7/8 2-9/16 758584 3, 4 7-5/8 5-3/16 3-7/8 2-9/16 958586 5, 6 9-3/4 7-3/8 3-7/8 2-9/16 11

q MAXIMUM SPACE AVAILABLE FOR PIPE FITTING ENCLOSURE, ETC.TYPE NO. PIPE SIZE A B C D q E LBS.58582-1 2 5-1/8 3-9/16 3-1/4 2-9/16 4 258584-1 3,4 6-3/4 5-3/16 3-1/4 2-9/16 5-3/4 458586-1 5,6 8-15/16 7-3/8 3-1/4 2-9/16 7-15/16 6

t Product Illustration follows.

Cleanouts_08.qxd 5/2/08 12:58 PM Page 196

APPLICATIONFor use in finished or unfinished floors subject to heavy wheel traffic or impact loads,such as warehouses, loading docks and warehouse stores. May be used with castiron or plastic cleanout ferrule and plug supplied by others. LEVELOC® thumb screwsallow top to be secured to ferrule.

SPECIFICATIONJOSAM 58580-1-SD Series ABS Floor Access Housing with special-duty scoriatedsecured round laminated satin Nikaloy cover and LEVELOC® screws.

CLEANOUTSCLEANOUTS

197

CLEAN

OU

TS

q MAXIMUM SPACE AVAILABLE FOR PIPE FITTING ENCLOSURE, ETC.TYPE NO. PIPE SIZE A q B C D LBS.58582-1-SD 2 6 3-3/16 4-1/8 2-9/16 758584-1-SD 3,4 7-5/8 5-3/16 4-1/8 2-9/16 958586-1-SD 5,6 9-3/4 7-3/8 4-1/8 2-9/16 11

q MAXIMUM SPACE AVAILABLE FOR PIPE FITTING ENCLOSURE, ETC.TYPE NO. PIPE SIZE A B C D q E LBS.58582-1-SQ 2 5-3/8 3-9/16 3-1/4 2-9/16 4 358584-1-SQ 3, 4 7 5-3/16 3-1/4 2-9/16 5-3/4 558586-1-SQ 5, 6 9-1/4 7-3/8 3-1/4 2-9/16 7-15/16 7

58580-1-SD SERIES with -1-SD Nikaloy Special-Duty Top

58580-1-SQ SERIES with -1-SQ Nikaloy Square TopAPPLICATION

For use in finished floors subject to pedestrian and light wheel traffic such as schools,hospitals and shopping malls where a square top complements construction or floorfinish. May be used with cast iron or plastic cleanout ferrule and plug supplied byothers. LEVELOC® thumb-screws allow top to be secured to ferrule.

SPECIFICATIONJOSAM 58580-1-SQ Series ABS Floor Access Housing with medium-duty scoriatedsecured square satin Nikaloy top and LEVELOC® screws.

Cleanouts_08.qxd 3/27/08 10:54 AM Page 197

CLEANOUTSCLEANOUTS

198

CLEA

NO

UTS

58600 SERIES WALL ACCESS COVER

58610 SERIES WALL OR FLOOR ACCESS COVER

APPLICATIONFor use in finished walls to conceal cleanout fittings.

SPECIFICATIONJOSAM 58600 Series round stainless steel Wall Access Cover with screw.

APPLICATIONFor use in finished walls or floors subject to pedestrian or light wheel traffic, to provideaccess to cleanout plugs, valves, controls or other equipment.

SPECIFICATIONJOSAM 58610 Series round cast Nikaloy Access Frame with anchor lugs and satinsmooth secured cover.

-2 Satin Finish Bronze Top-10 Scoriated Cover-14 Carpet Cleanout Marker-VP Secured Cover, Vandal-Proof Screws-CO2 No-Hub Cleanout, 2”-CO3 No-Hub Cleanout, 3”-CO4 No-Hub Cleanout, 4”-CO6 No-Hub Cleanout, 6”-20 ** Raised Head Bronze Plug-31 ** Galvanized Cast Iron Parts-COT2 No-Hub Cleanout Tee, 2”-COT3 No-Hub Cleanout Tee, 3”-COT4 No-Hub Cleanout Tee, 4”-COT6 No-Hub Cleanout Tee, 6”

-VP Secured Cover,Vandal-Proof Screws

-17 Center Screw Longer than Standard

-PLG1-1/2 Bronze NPT Plug, 1-1/2”-PLG2 Bronze NPT Plug, 2”-PLG2-1/2 Bronze NPT Plug, 2-1/2”-PLG3 Bronze NPT Plug, 3”-PLG3-1/2 Bronze NPT Plug, 3-1/2”-PLG4 Bronze NPT Plug, 4”-PLG5 Bronze NPT Plug, 5”

-PLG6 Bronze NPT Plug, 6”-20 * Raised Head Bronze Plug-CO2 No-Hub Cleanout, 2”-CO3 No-Hub Cleanout, 3”-CO4 No-Hub Cleanout, 4”-CO6 No-Hub Cleanout, 6”-31 ** Galv. Cast Iron Parts-COT2 No-Hub Cleanout Tee, 2”-COT3 No-Hub Cleanout Tee, 3”-COT4 No-Hub Cleanout Tee, 4”-COT6 No-Hub Cleanout Tee, 6”

Available Options

Available Options

TYPE NO. B LBS.58604 5-3/8 158606 7-5/8 158608 10-5/8 1

TYPE NO. PIPE SIZE B C D LBS.58614 2, 3, 4 4-5/8 6 5-1/2 458616 5, 6 6-3/4 8-1/4 7-3/4 758618 8 9-3/8 10-7/8 10-3/8 10

* Specify -PLG** Specify -CO or -COT

** Specify -CO or -COT

Cleanouts_08.qxd 3/27/08 10:54 AM Page 198

APPLICATIONFor use in finished walls or floors subject to pedestrian or light wheel traffic, to pro-vide access to cleanout plugs, valves, controls or other equipment. Hinged coverallows for easy access.

SPECIFICATIONJOSAM 58620 Series round cast Nikaloy Access Frame with anchor flange and satinsmooth hinged cover.

CLEANOUTSCLEANOUTS

199

CLEAN

OU

TS

APPLICATIONFor use in finished walls or floors subject to pedestrian or light wheel traffic, to pro-vide access to cleanout plugs, valves, controls or other equipment where a squarecover complements construction or finish. Hinged cover allows for easy access.

SPECIFICATIONJOSAM 58630 Series square cast Nikaloy Access Frame with anchor lugs and satinscoriated secured hinged cover.

-2 Satin Finish Bronze Top-10 Scoriated Cover-14 Carpet Cleanout Marker-VP Secured Cover,

Vandal-Proof Screws-CO2 No-Hub Cleanout, 2”-CO3 No-Hub Cleanout, 3”-CO4 No-Hub Cleanout, 4”

-CO6 No-Hub Cleanout, 6”-20 ** Raised Head Bronze Plug-31 ** Galvanized Cast Iron Parts-COT2 No-Hub Cleanout Tee, 2”-COT3 No-Hub Cleanout Tee, 3”-COT4 No-Hub Cleanout Tee, 4”-COT6 No-Hub Cleanout Tee, 6”

-2 Satin Finish Bronze Top-VP Secured Cover, Vandal-Proof

Screws-CO2 No-Hub Cleanout, 2”-CO3 No-Hub Cleanout, 3”-CO4 No-Hub Cleanout, 4”-CO6 No-Hub Cleanout, 6”

-20 ** Raised Head Bronze Plug-31 ** Galvanized Cast Iron Parts-COT2 No-Hub Cleanout Tee, 2”-COT3 No-Hub Cleanout Tee, 3”-COT4 No-Hub Cleanout Tee, 4”-COT6 No-Hub Cleanout Tee, 6

Available Options

Available Options

58630 SERIES WALL OR FLOOR ACCESS COVER

58620 SERIES WALL OR FLOOR ACCESS COVER

TYPE NO. PIPE SIZE B C D E LBS.58624 2,3,4 5-3/8 6-5/8 6-1/4 3/4 558626 5,6 6-7/8 8-3/8 8 1 7

TYPE NO. A X A B X B C LBS.58631 8 x 8 6x 6 5-1/2 758632 12 x 12 10 x 10 9-1/2 15

** Specify -CO or -COT

** Specify -CO or -COT

Cleanouts_08.qxd 3/27/08 10:54 AM Page 199

APPLICATIONFor use in finished walls or floors subject to pedestrian or light wheel traffic, to pro-vide access to cleanout plugs, valves, controls or other equipment where a squarecover complements construction or finish.

SPECIFICATIONJOSAM 58640 Series square cast Nikaloy Access Frame with anchor lugs and satinsmooth secured cover.

CLEANOUTSCLEANOUTS

200

CLEA

NO

UTS

58640 SERIES WALL OR FLOOR ACCESS COVER

58650 SERIES WALL ACCESS COVERAPPLICATION

For use in finished walls to provide access to cleanout plugs, valves, controls or otherequipment where a square cover, flush-with-wall, complements construction or finish.

SPECIFICATIONJOSAM 58650 Series square stainless steel Access Frame with beveled edge, anchorlugs and smooth, secured cover.

-2 Satin Finish Bronze Top-10 Scoriated Cover-VP Secured Cover, Vandal-Proof

Screws-CO2 No-Hub Cleanout, 2”-CO3 No-Hub Cleanout, 3”-CO4 No-Hub Cleanout, 4”

-CO6 No-Hub Cleanout, 6”-20 ** Raised Head Bronze Plug-31 ** Galvanized Cast Iron Parts-COT2 No-Hub Cleanout Tee, 2”-COT3 No-Hub Cleanout Tee, 3”-COT4 No-Hub Cleanout Tee, 4”-COT6 No-Hub Cleanout Tee, 6”

-VP Secured Cover,Vandal-Proof Screws

-CO2 No-Hub Cleanout, 2”-CO3 No-Hub Cleanout, 3”-CO4 No-Hub Cleanout, 4”-CO6 No-Hub Cleanout, 6”

-20 ** Raised Head Bronze Plug-31 ** Galvanized Cast Iron Parts-COT2 No-Hub Cleanout Tee, 2”-COT3 No-Hub Cleanout Tee, 3”-COT4 No-Hub Cleanout Tee, 4”-COT6 No-Hub Cleanout Tee, 6”

Available Options

Available Options

TYPE NO. A X A B X B C X C LBS.58642 7 x 7 6-1/2 x 6-1/2 6 x 6 558644 9 x 9 8-1/2 x 8-1/2 8 x 8 858646 10 x 10 9-1/2 x 9-1/2 9 x 9 10

TYPE NO. LBS.58656 4

** Specify -CO or -COT

** Specify -CO or -COT

Cleanouts_08.qxd 5/2/08 12:59 PM Page 200

CLEANOUTSCLEANOUTS

201

CLEAN

OU

TS

58600-PLG SERIES 58600-CO SERIES

APPLICATIONFor use in finished or unfinished floors, inside or outdoors, subject to heavy wheeltraffic, such as parking lots, warehouses or industrial areas. To provide access tocleanout plugs, valves, controls or other equipment.

SPECIFICATIONJOSAM 58680 Series round coated cast iron Access Frame with anchor flanges andheavy-duty scoriated secured cover.

-5 Ductile Iron Cover-VP Secured Cover, Vandal-Proof Screws-26 Gasketed Cover-31 Galvanized Cast Iron Parts-CO2 No-Hub Cleanout, 2”-CO3 No-Hub Cleanout, 3”-CO4 No-Hub Cleanout, 4”-CO6 No-Hub Cleanout, 6”-20 Raised Head Bronze Plug

Special Wording on Cover, SAN. or STORM, (Specify On Order)

58680 SERIES ACCESS COVER

TYPE NO. LBS.58680 37

Available Options

TYPE NO. PIPE SIZE B C LBS.58604-CO2 2 1-1/2 5-3/8 658604-CO3 3 2-1/2 5-3/8 758604-CO4 4 3-1/2 5-3/8 958606-CO6 6 5-1/2 7-5/8 26

TYPE NO PIPE SIZE B LBS.58604-PLG1-1/2 1-1/2 5-3/8 158604-PLG2 2 5-3/8 158604-PLG2-1/2 2-1/2 5-3/8 158604-PLG3 3 5-3/8 158604-PLG3-1/2 3-1/2 5-3/8 158606-PLG4 4 7-5/8 258606-PLG5 5 7-5/8 358606-PLG6 6 7-5/8 4

Cleanouts_08.qxd 3/27/08 10:54 AM Page 201

CLEANOUTSCLEANOUTS

202

CLEA

NO

UTS

58600-COT SERIES

58610-COT SERIES

58610-CO SERIES

58630-CO SERIES

TYPE NO. PIPE SIZE B C E F LBS.58614-CO2 2 1-1/2 4-5/8 6 5-1/2 658614-CO3 3 2-1/2 4-5/8 6 5-1/2 758614-CO4 4 3-1/2 4-5/8 6 5-1/2 958616-CO6 6 5-1/2 6-3/4 8-1/4 7-3/4 15

TYPE NO. PIPE SIZE B C X C LBS.58631-CO2 2 1-1/2 8 x 8 958631-CO3 3 2-1/2 8 x 8 958631-CO4 4 3-1/2 8 x 8 1158632-CO6 6 5-1/2 12 x 12 20

TYPE NO. PIPE SIZE B C D E F LBS.58604-COT2 2 4-1/4 1-3/4 6-3/8 2 5-3/8 1158604-COT3 3 5-1/4 2-1/2 7-3/4 3 5-3/8 1458604-COT4 4 6 3-1/2 8-7/8 4 5-3/8 2058608-COT6 6 7 4-1/2 12-1/2 6 10-5/8 34

TYPE NO. PIPE SIZE B C D E F LBS.58614-COT2 2 4-1/4 1-3/4 6-3/8 2 6 1358614-COT3 3 5-1/4 3-1/2 7-3/4 3 6 1658614-COT4 4 6 3-1/2 8-7/8 4 6 2258616-COT6 6 7 4-1/2 12-1/2 6 8-1/4 37

Cleanouts_08.qxd 3/27/08 10:54 AM Page 202

CLEANOUTSCLEANOUTS

203

CLEAN

OU

TS

58630-COT SERIES

58640-COT SERIES

58640-CO SERIES

TYPE NO. PIPE SIZE B C X C LBS.58642-CO2 2 1-1/2 7 x 7 758642-CO3 3 2-1/2 7 x 7 858642-CO4 4 3-1/2 7 x 7 1058644-CO6 6 5-1/2 9 x 9 16

TYPE NO. PIPE SIZE B C D E F X F LBS.58631-COT2 2 4-1/4 1-3/4 6-3/8 2 8 x 8 1658631-COT3 3 5-1/4 2-1/2 7-3/4 3 8 x 8 1958631-COT4 4 6 3-1/2 8-7/8 4 8 x 8 2558632-COT6 6 7 4-1/2 12-1/2 6 12 x 12 42

TYPE NO. PIPE SIZE B C D E F X F LBS.58642-COT2 2 4-1/4 1-3/4 6-3/8 2 7 x 7 1458642-COT3 3 5-1/4 2-1/2 7-3/4 3 7 x 7 1758642-COT4 4 6 3-1/2 8-7/8 4 7 x 7 2358644-COT6 6 7 4-1/2 12-1/2 6 9 x 9 38

Cleanouts_08.qxd 3/27/08 10:54 AM Page 203

CLEANOUTSCLEANOUTS

204

CLEA

NO

UTS

APPLICATIONFor use in unfinished areas not subject to traffic.

SPECIFICATIONJOSAM 58900 Series coated cast iron Cleanout Ferrule with no-hub connection andbronze countersunk plug.

APPLICATIONFor use in concealed walls with no-hub pipe.

SPECIFICATIONJOSAM 58910 Series coated cast iron Cleanout Tee, no-hub connection and bronze plug.

-19 Plug Tapped for Center Screw-20 Raised Head Bronze Plug-31 Galvanized Cast Iron Parts

OUTLET:-Z No-Hub Outlet

-19 Plug Tapped for Center Screw-20 Raised Head Bronze Plug-31 Galvanized Cast Iron Parts

OUTLET:-Z No-Hub Outlet

58900 SERIES NO-HUB CLEANOUT FERRULE

58910 SERIES NO-HUB CLEANOUT TEE WITH PLUG

Available Options

Available Options

FOR OUTLET TYPE SPECIFY -ZTYPE NO. PIPE SIZE B C LBS.58902 2 1-3/4 1-1/2 258903 3 1-3/4 2-1/2 258904 4 1-3/4 3-1/2 358906 6 3-3/4 5 7

FOR OUTLET TYPE SPECIFY -ZTYPE NO. PIPE SIZE B C LBS.58912 2 6-3/8 2 558913 3 7-3/4 3 858914 4 8-7/8 4 1258916 6 12-1/2 6 20

Cleanouts_08.qxd 3/27/08 10:54 AM Page 204

205

GREASE INTERCEPTORSGREASE INTERCEPTORSIN

TERCEPTORS

Grease Interceptor FeaturesA grease interceptor is a plumbing device installed in the sanitary drainage system to intercept fats, oils and grease (FOG) from the waste waterdischarge. It works by slowing the flow of water into the interceptor, which allows the FOG time to separate from the waste water. The FOG iscontained in the body of the interceptor allowing the FOG-free water to pass downstream by exiting the interceptor via a trap leg. Hydro-mechanicalgrease interceptors range in size from small 7 GPM units to large 500 GPM units. Units with installed grease removal devices are self-cleaning.For maximum grease efficiency JOSAM provides an external flow control with every interceptor which must be used as directed.

60100H-GRD TIMER-CONTROLLED GREASE REMOVAL PUMP

TIMER/CONTROLLERWall-mounted Programmable Timeractivates evacuation pump at pre-determined time (1-99 Days).

GREASE REMOVAL PUMPevacuates contained grease regardless of temperature.

EXTERNAL FLOW CONTROLWITH AIR INTAKE (Not Shown)

REMOVABLE BAFFLE

SECURED COVER (Removed)White acid-resisting coating,gasketed air and watertight,single-bolt, non-skid safety pattern.

NO-HUBInlet/Outlet Connections

BODYSteel with whiteacid-resisting coating

INTERNALTRAP LEG

RECLAIM CHAMBERprovides visual evidence thatgrease layer is removed, assuringcorrect interval has been selected.

GRDP OPTIONincludes the sensing and alarm probe which enables the use of the probe as the primary source of sensing with the timer as a back-up system.

Interceptors_08.qxd 3/27/08 11:58 AM Page 205

206

INTERCEPTORS INTERCEPTORSIN

TERC

EPTO

RS

This checklist of interceptors is provided as a guide to selection of the proper type interceptor to control specific waste materials. First determine the waste material to becontrolled, then follow the check marks for the types of interceptors recommended.

How to OrderSelect Type Number from Dimension Table and use suffix numbers to indicate options.

EXAMPLE: Series No. 60100H Type No. 6010

60106H -EXT -ISI

Type No.Option, Integral ExtensionOption, Integrated Solids Interceptor

HOW TO ORDER INTERCEPTORS WITH EXTENDED TOPSWhen ordering extensions for Grease and Oil Interceptors (-EXT), specify dimension from the pipe centerline to finished floor.

Selection Checklist

TYPE OFWASTE

MATERIAL

TYPES OF INTERCEPTORS

GREASE INTERCEPTORSOIL

SEPARATORSSOLIDS INTERCEPTORS

AUTOMATICSEMI-

AUTOMATIC MANUAL AUTOMATIC

Barium P PBenzine P P P P P PCheese P P P P P P P P P P P P P PCutting Oils P P P P P PElemental Mercury* PFats P P P P P P P P P P P P P PGasoline P P P P P PGauze P P PGlass Grindings PGravel P P P PGrease P P P P P P P P P P P P P PHair P P P PJewels P P PKerosene P P P P PLint P P P P PLubricating Oil P P P P P PNaphtha P P P P P POil P P P P P POil Sludge PParaffin P P P P P P P P P PPlaster P PPrecious Metals P P PQuench Oil P P P P P PRouge PRubber Grindings PSand P P P PSediment P P P PWax P P P P P P P P P P

*Cast Iron Interceptor Only

6010

0H-G

RD

6030

0A

6010

0-SA

6011

0-SA

6010

0-SA

-RT

6010

0-SA

-ET

6010

0H

6011

5A

6011

7A

6010

0H-E

XT

6010

0H-R

T

6010

0H-E

T

6021

0A

6021

0A-E

XT

6050

0B

6050

0B-E

XT

6050

0-ES

T

6061

0A

6061

0A-E

XT

6061

0-ES

T

6081

0

6100

0

6103

0

6104

0

6107

0

6108

0

6180

0

Interceptors_08.qxd 3/27/08 11:58 AM Page 206

207

GREASE INTERCEPTORSGREASE INTERCEPTORSIN

TERCEPTORS

SizingConsult PDI-G101 or ASME A112.14.3 Standards or your local codes.

Selection Table

TYPE NO.RATING

IN G.P.M.INLET & OUTLETSIZE (INCHES)

AUTOMATIC TYPE

60306A 25 3

60307A 35 3

60308A 50 3

60309A 75 4

60310A 100 4

60311A 150 4

60312A 200 6

60313A 250 6

60314A 350 6

60315A 500 6

SEMI-AUTOMATIC TYPE

60102-SA, -RT, -ET 7 2

60103-SA, -RT, -ET 10 2

60104-SA, -RT, -ET 15 2

60105-SA, -RT, -ET 20 3

60106-SA, -RT, -ET 25 3

60107-SA, -RT, -ET 35 3

60108-SA, -RT, -ET 50 3

SEMI-AUTOMATIC LOW TYPE

60115-SA 35 3

GREASE MONITORING DEVICE

EGOLD-1000

CEGOLD-2000

-SAP

TYPE NO.RATING

IN G.P.M.INLET & OUTLETSIZE (INCHES)

MANUAL CLEANING TYPE

60102H, -EXT, -RT, -ET 7 2

60103H, -EXT, -RT, -ET 10 2

60104H, -EXT, -RT, -ET 15 2

60105H, -EXT, -RT, -ET 20 3

60106H, -EXT, -RT, -ET 25 3

60107H, -EXT, -RT, -ET 35 3

60108H, -EXT, -RT, -ET 50 3

60109H, -EXT, -RT, -ET 75 3

60110H, -EXT, -RT, -ET 100 4

MANUAL CLEANING LOW TYPE

60115A 20 2

60117A 35 3

MANUAL CLEANING HIGH VOLUME TYPE

60213A, -EXT 150 4

60214A, -EXT 200 5

60215A, -EXT 250 5

60216A, -EXT 350 6

60217A, -EXT 500 6

Interceptors_08.qxd 3/27/08 11:58 AM Page 207

INTERCEPTORS • Pictorial Selection GuideINTERCEPTORS • Pictorial Selection Guide

208

INTE

RCEP

TORS

AUTOMATIC ELECTRONIC GREASE/OIL LEVEL DETECTORS60300AGI-2000A Fully Electronic SS Interceptor

Page 219

60100H-GRDGrease Removal Device

Page 211

EGOLD-1000Monitoring Device forInterceptors Inside Building

Page 220

CEGOLD-2000Monitoring Device forInterceptors Outside Building

Page 220

SAPSensing & Alarm Probe

Page 217

MANUAL CLEANING60115A/60117ALow-Boy

Page 216

60210AHigh Volume

Page 217

60210A-EXTHigh Volume, Extended Top

Page 218

MANUAL CLEANING60100HOn-Floor Type

Page 211

60100H-EXTExtended Top

Page 212

60100H-ETEnclosed Top

Page 212

60100H-RTRecessed Type

Page 213

SEMI-AUTOMATIC CLEANING60100-SAOn-Floor Type

Page 214

60100-SA-ETEnclosed Type

Page 215

60100-SA-RTRecessed Type

Page 215

60115-SALow Boy

Page 216

Interceptors_08.qxd 3/27/08 11:58 AM Page 208

INTERCEPTORS • Pictorial Selection GuideINTERCEPTORS • Pictorial Selection Guide

209

INTERCEPTO

RS

OIL SEPARATORS60500BGravity-Type Draw-Off

Page 225

60500B-EXTExtended Top, Draw-Off Type

Page 225

60500-ESTwith External Storage Tank

Page 226

OIL SEPARATORS60610AHigh Volume, Draw-Off Type

Page 227

60610A-EXTHigh Volume, Extended Top, Draw-Off Type

Page 227

60610-ESTHigh Volume with External Storage Tank

Page 228 (EST NOT SHOWN)

OIL/SEDIMENT LINT INTERCEPTOR60810

Page 229

61800Galvanized Steel Bucket

Page 232

SOLIDS INTERCEPTORS61000Barber Shop Type, Bottom Access

Page 229

61030Jewelry Shop Type, Top Access

Page 229

61040A18" x 18" Top Access

Page 230

61070 6108010-1/2" Top 16-1/2” Top

Top Access

Pages 230, 231

Interceptors_08.qxd 3/27/08 11:58 AM Page 209

210

GREASE INTERCEPTORS GREASE INTERCEPTORSIN

TERC

EPTO

RS

Typical InstallationsThe typical illustrations shown below are suggested ways of installing various types of JOSAM Interceptors. All installations are subject togovernment and local code requirements.

60100H Series Interceptor on floor, servicing a sink. 60110-SA Series Semi-Automatic shallow Interceptor installed onfloor, servicing a double compartment sink and dishwasher.

60115A Series Interceptor installed on floor under sink.(Recommended only if there is adequate head room for coverremoval and service.)

NOTE: Install air intake from flow control to outside of building and terminate with elbow, turned down or intersect a local vent or vent stack without trap if permittedby code. Top of air intake from flow control should not be lower than rim of fixture.

60100H-EXT Series Interceptor recessed with deep roughingextended flush with floor.

60100-SA-RT Series Semi-Automatic Interceptor recessed flush withfloor, servicing a dishwasher.

60210A-EXT Series Interceptor recessed flush with floor, servicing asink and an additional fixture.

Interceptors_08.qxd 3/27/08 11:58 AM Page 210

APPLICATIONFor use in restaurant and institutional kitchens and all types of food handling andprocessing areas where waste water contains fats, oil and grease (FOG). Adequatespace and head room for removal of cover must be available for manual cleaning.

SPECIFICATIONJOSAM 60100H Series epoxy coated fabricated steel Grease Interceptor, no-hub connec-tions, internal trap, removable diffuser baffle, gasketed non-skid cover, flow control fittingand PDI Seal of Approval. Conforms to Plumbing & Drainage Institute Standard PDI-G101.

Conforms to Plumbing and Drainage Institute Standard PDI-G101.

Available Options-40 Cover Recess for Floor Finish-61 Flange and Clamp Device

* -ISI Integrated Solids Interceptort -EXT Extension, 6” Standard.

(Specify Extension Height)t -RT Recessed Typet -ET Enclosed Type

-HD Heavy-Duty Cover-SS Stainless Steel Interceptor

t -GRD* Grease Removal Device,60104H-60110H

† -GRDP Grease Recovery Devicewith Probe

-SAP Sensing and Alarm Probe

APPLICATIONFor use in restaurant and institutional kitchens and all types of food handling andprocessing areas where waste water contains fats, oil and grease (FOG). The GreaseRemoval Device (GRD), with programmable timer, controls the internal pump toremove grease on schedule.

SPECIFICATIONJOSAM 60100H-GRD Series epoxy coated fabricated steel Grease Interceptor, no-hubconnections, internal trap, removable baffle, gasketed non-skid cover, flow control fit-ting and PDI Seal of Approval. Programmable timer controls internal pump forremoval of grease at predetermined intervals.

OPTION N/A:-ISI

GREASE INTERCEPTORSGREASE INTERCEPTORS

211

INTERCEPTO

RSTYPE NO.

FLOWRATEGPM

GREASECAPLBS.

PIPESIZE

ROUGH-INCENTERS LGTH.

EWIDTH

FHGT.

G LBS.C D60102H 7 14 2 8-1/4 3-3/8 14-7/8 13 11-5/8 3560103H 10 20 2 8-1/2 3-3/8 16-5/8 14-1/2 11-7/8 4560104H 15 30 2 9-1/2 3-3/8 20-3/8 17 12-7/8 6060105H 20 40 3 12 4-7/8 20-7/8 19 16-7/8 7060106H 25 50 3 13 4-7/8 23-3/8 21-1/2 17-7/8 9060107H 35 70 3 14-1/2 4-7/8 26-1/8 23 19-3/8 11060108H 50 100 3 16-1/2 4-7/8 27-7/8 25-1/2 21-3/8 13560109H 75 150 3 21 6 41 31 27 22060110H 100 200 4 23 8 47 35 31 325

* -ISI and -GRD cannot be furnished together. † 60100H-GRDP meets ANSI A112.14.4

60100H SERIES MANUAL CLEANING, ON-FLOOR TYPE

t Product Illustration follows.

60100H-GRD SERIES with Grease Removal Device

TYPE NO.

FLOWRATEGPM

GREASECAPLBS.

PIPESIZE

ROUGH-INCENTERS LGTH.

EWIDTH

FHGT.

G LBS.C D

60104H-GRD 15 30 2 9-1/2 3-3/8 20-3/8 17 12-7/8 9060105H-GRD 20 40 3 12 4-7/8 20-7/8 19 16-7/8 10060106H-GRD 25 50 3 13 4-7/8 23-3/8 21-1/2 17-7/8 12060107H-GRD 35 70 3 14-1/2 4-7/8 26-1/8 23 19-3/8 14060108H-GRD 50 100 3 16-1/2 4-7/8 27-7/8 25-1/2 21-3/8 16560109H-GRD 75 150 3 21 6 41 31 27 25060110H-GRD 100 200 4 23 8 47 35 31 355

Interceptors_08.qxd 5/2/08 3:02 PM Page 211

GREASE INTERCEPTORSGREASE INTERCEPTORS

212

INTE

RCEP

TORS

APPLICATIONFor use in restaurant and institutional kitchens and all types of food handling andprocessing areas where waste water contains fats, oil and grease (FOG). Extendedtop with fixed extension for installations requiring additional roughing depth fromthe cover of the interceptor to the inlet and outlet.

SPECIFICATIONJOSAM 60100H-EXT Series epoxy coated fabricated steel Grease Interceptor, deeproughing, integral extension, flush-with-floor type, no-hub connections, internal trap,removable diffuser baffle, gasketed non-skid cover, flow control fitting and PDI Seal of Approval.

Conforms to Plumbing and Drainage Institute Standard PDI-G101.

60100H-EXT SERIES with Extension

60100H-ET SERIES Enclosed Type

TYPE NO.

FLOWRATEGPM

GREASECAPLBS.

PIPESIZE

ROUGH-INCENTERS LGTH.

EWIDTH

FHGT.

G LBS.C D©60102H-EXT 7 14 2 8-1/4 9-3/8 14-7/8 13 17-5/8 3560103H-EXT 10 20 2 8-1/2 9-3/8 16-5/8 14-1/2 17-7/8 4560104H-EXT 15 30 2 9-1/2 9-3/8 20-3/8 17 18-7/8 6060105H-EXT 20 40 3 12 10-7/8 20-7/8 19 22-7/8 7060106H-EXT 25 50 3 13 10-7/8 23-3/8 21-1/2 23-7/8 9060107H-EXT 35 70 3 14-1/2 10-7/8 26-1/8 23 25-3/8 11060108H-EXT 50 100 3 16-1/2 10-7/8 27-7/8 25-1/2 27-3/8 13560109H-EXT 75 150 3 21 12 41 31 33 22060110H-EXT 100 200 4 23 14 47 35 37 325

© DIMENSIONS BASED ON STD. 6" EXTENSION.

APPLICATIONFor use in restaurant and institutional kitchens and all types of food handling andprocessing areas where waste water contains fats, oil and grease (FOG). Steel enclo-sure cabinet for installation flush with the floor, completely encased, where adjust-ment of interceptor elevation is necessary for connection to a deep drain line.

SPECIFICATIONJOSAM 60100H-ET Series epoxy coated fabricated steel Grease Interceptor, deeproughing, flush-with-floor type, no-hub connections, internal trap, removable diffuserbaffle, gasketed non-skid cover, flow control fitting, PDI Seal of Approval and steelenclosure cabinet with non-skid cover and adjustable interceptor carrier brackets.

Conforms to Plumbing and Drainage Institute Standard PDI-G101.

© BASED ON INTERCEPTOR IN POSITION #1, ADD 1-1/4" WHEN LOWERING INTERCEPTORTO SUCCEEDING POSITIONS.

INTERCEPTOR SUPPORT BRACKET ADJUSTABLE FOR VARYING DEPTHS OF FLOORCONSTRUCTION.

TYPE NO.

FLOWRATEGPM

GREASECAPLBS.

PIPESIZE

WIDTHB

ROUGH-INCENTERS INTER.

LGTH.E

ENCL.LGTH.

FHGT.

G LBS.C D©60102H-ET 7 14 2 15 8-1/4 8-3/4 14-7/8 23 25-3/4 14360103H-ET 10 20 2 16-1/2 8-1/2 8-3/4 16-5/8 24-3/4 26 18560104H-ET 15 30 2 19 9-1/2 8-3/4 20-3/8 28-1/2 27 23260105H-ET 20 40 3 21 12 10-1/4 20-7/8 29 31 27460106H-ET 25 50 3 23-1/2 13 10-1/4 23-3/8 31-1/2 32 35660107H-ET 35 70 3 25 14-1/2 10-1/4 26-1/8 34-1/4 33-1/2 37860108H-ET 50 100 3 27-1/2 16-1/2 10-1/4 27-7/8 36 35-1/2 43560109H-ET 75 150 3 33 21 11-3/8 41 49-1/8 41-1/8 78060110H-ET 100 200 4 37 23 13-3/8 47 55-1/8 45-1/8 1075

Interceptors_08.qxd 5/2/08 3:02 PM Page 212

APPLICATIONFor use in restaurant and institutional kitchens and all types of food handling andprocessing areas where waste water contains fats, oil and grease (FOG). Steel frameand cover for installation flush with the floor where adjustment of interceptor eleva-tion is necessary for connection to a deep drain line.

SPECIFICATIONJOSAM 60100H-RT Series epoxy coated fabricated steel Grease Interceptor, deeproughing, recessed, flush-with-floor type, no-hub connections, internal trap, removablediffuser baffle, gasketed non-skid cover, flow control fitting, PDI Seal of Approval andsteel frame with non-skid cover and adjustable interceptor carrier brackets.

Conforms to Plumbing and Drainage Institute Standard PDI-G101.

GREASE INTERCEPTORSGREASE INTERCEPTORS

213

INTERCEPTO

RS

60100H-RT SERIES Recessed Type

TYPE NO.

FLOWRATEGPM

GREASECAPLBS.

PIPESIZE

WIDTHB

ROUGH-INCENTERS INTER.

LGTH.E

ENCL.LGTH.

FHGT.

G LBS.C D©60102H-RT 7 14 2 15 8-1/4 8-3/4 14-7/8 19 14-3/4 10260103H-RT 10 20 2 16-3/8 8-1/2 8-3/4 16-5/8 21 14-3/4 12060104H-RT 15 30 2 18-1/2 9-1/2 8-3/4 20-3/8 24 14-3/4 15160105H-RT 20 40 3 20-1/4 12 10-1/4 20-7/8 26 14-3/4 17560106H-RT 25 50 3 22-1/2 13 10-1/4 23-3/8 29 14-7/8 19760107H-RT 35 70 3 24 14-1/2 10-1/4 26-1/8 31 14-7/8 22560108H-RT 50 100 3 26-5/8 16-1/2 10-1/4 27-7/8 33 14-7/8 25860109H-RT 75 150 3 33 21 11-3/8 41 49-1/8 15-3/4 45560110H-RT 100 200 4 37 23 13-3/8 47 55-1/8 15-3/4 625

© BASED ON INTERCEPTOR IN POSITION #1, ADD 1-1/4" WHEN LOWERING INTERCEPTORTO SUCCEEDING POSITIONS.

INTERCEPTOR SUPPORT BRACKET ADJUSTABLE FOR VARYING DEPTHS OF FLOORCONSTRUCTION.

Interceptors_08.qxd 5/2/08 4:26 PM Page 213

GREASE INTERCEPTORSGREASE INTERCEPTORS

214

INTE

RCEP

TORS

APPLICATIONFor use in restaurant and institutional kitchens and all types of food handling andprocessing areas where waste water contains fats, oil and grease (FOG). Semi-auto-matic draw-off allows for easy odor and mess free grease removal without openingthe cover.

SPECIFICATIONJOSAM 60100-SA Series epoxy coated fabricated steel Grease Interceptor withthreaded connections, internal air relief, visible double wall trap, removable baffle,gasketed non-skid cover, grease recovery cone, flexible hose, grease draw-off valveand flow control fitting.

• -62 4” Inlet and Outlet Availableon Std. 3” Sizes

-65 Hub Inlet, Spigot Outlet, 2”-66 Hub Inlet, Spigot Outlet, 3”-67 Hub Inlet, Spigot Outlet, 4”

t -ET Enclosed Typet -RT Recessed Type

Available Options

• 3” sizes normally furnished with 4” x 3” reducing bushings.

TYPE NO.

FLOWRATEGPM

GREASECAPLBS.

PIPESIZE

ROUGH-INCENTERS LGTH.

EWIDTH

FHGT.

G LBS.C D60102-SA 7 14 2 7-3/8 2-1/4 20-7/16 9-15/16 9-5/8 3160103-SA 10 20 2 8-3/8 2-7/8 22-1/16 11-9/16 11-1/4 4060104-SA 15 30 2 9-3/8 4 24-3/16 13-3/16 13-3/8 4760105-SA 20 40 2 11-1/2 4-5/8 26-15/16 14-13/16 16-1/8 8860106-SA 25 50 3• 13 4-3/8 32 16-7/8 17-3/8 12360107-SA 35 70 3• 14-1/2 4 33-5/8 17-7/8 18-1/2 12760108-SA 50 100 3• 15-1/2 4-7/8 37-1/4 19-3/4 20-3/8 197

t Product Illustration follows.

60100-SA SERIES SEMI-AUTOMATIC

NOTE: HGT. OF 13" REQUIRED FROM TOP OF INTERCEPTOR TO BOTTOM OF FIXTURE.

Interceptors_08.qxd 5/2/08 3:02 PM Page 214

GREASE INTERCEPTORSGREASE INTERCEPTORS

215

INTERCEPTO

RS

60100-SA-RT SERIES Recessed Type

APPLICATIONFor use in restaurant and institutional kitchens and all types of food handling andprocessing areas where waste water contains fats, oil and grease (FOG). Semi-auto-matic draw-off allows for easy odor and mess free grease removal without openingthe cover. Steel enclosure cabinet for installation flush with the floor, completelyencased, where adjustment of interceptor elevation is necessary for connection to adeep drain line.

SPECIFICATIONJOSAM 60100-SA-ET Series epoxy coated fabricated steel semi-automatic GreaseInterceptor with threaded connections, internal air relief, visible double wall trap,removable baffle, gasketed cover, grease recovery cone, flexible hose and greasedraw-off valve, flow control fitting and steel enclosure cabinet with non-skid coverand adjustable interceptor carrier brackets.

APPLICATIONFor use in restaurant and institutional kitchens and all types of food handling andprocessing areas where waste water contains fats, oil and grease (FOG). Semi-automaticdraw-off allows for easy odor and mess free grease removal without opening the cover.Steel frame and cover for installation flush with the floor where adjustment of intercep-tor elevation is necessary for connection to deep drain line.

SPECIFICATIONJOSAM 60100-SA-RT Series epoxy coated fabricated steel semi-automatic GreaseInterceptor with acid-resisting coating, deep roughing flush-with-floor type, threadedconnections, flat bottom, internal air relief, visible double wall trap, removable baf-fle, gasketed non-skid cover, grease recovery cone, flexible hose and grease draw-offvalve, flow control fitting and steel frame with non-skid cover and adjustable inter-ceptor carrier brackets.

TYPE NO.

FLOWRATEGPM

GREASECAPLBS.

PIPESIZE

WIDTHB

ROUGH-INCENTERS

ELGTH.

FHGT.

G LBS.C D©60102-SA-ET 7 14 2 11 7-3/8 7-5/8 20-7/16 27-1/2 24-5/8 13660103-SA-ET 10 20 2 12-5/8 8-3/8 8-1/4 22-1/16 29 25-7/8 17760104-SA-ET 15 30 2 14-1/4 9-3/8 9-3/8 24-3/16 31-1/4 27-1/8 21660105-SA-ET 20 40 2 16 11-1/2 10 26-15/16 34 29-1/8 28960106-SA-ET 25 50 3• 17-1/2 13 9-3/4 32 38 31-1/2 36060107-SA-ET 35 70 3• 18-1/2 14-1/2 9-3/8 33-5/8 39-1/2 32-5/8 38960108-SA-ET 50 100 3• 20-1/4 15-1/2 10-1/4 37-1/4 43-1/8 34-5/8 491

TYPE NO.

FLOWRATEGPM

GREASECAPLBS.

PIPESIZE

WIDTHB

ROUGH-INCENTERS

ELGTH.

FHGT.

G LBS.C D©60102-SA-RT 7 14 2 11 7-3/8 7-5/8 20-7/16 27-1/2 14-3/4 12760103-SA-RT 10 20 2 12-5/8 8-3/8 8-1/4 22-1/16 29 14-3/4 14460104-SA-RT 15 30 2 14-1/4 9-3/8 9-3/8 24-3/16 31-1/4 14-3/4 15960105-SA-RT 20 40 2 16 11-1/2 10 26-15/16 34 14-3/4 20860106-SA-RT 25 50 3• 17-1/2 13 9-3/4 32 38 14-3/4 25560107-SA-RT 35 70 3• 18-1/2 14-1/2 9-3/8 33-5/8 39-1/2 14-7/8 26060108-SA-RT 50 100 3• 20-1/4 15-1/2 10-1/4 37-1/4 43-1/8 14-7/8 338

60100-SA-ET SERIES Enclosed Type

NOTE: HGT. OF 13" REQUIRED FROM TOP OF INTERCEPTOR TO BOTTOM OF FIXTURE.

© BASED ON INTERCEPTOR IN POSITION #1, ADD 1-1/4" WHEN LOWERING INTERCEPTOR TO SUCCEEDING POSITIONS. INTERCEPTOR SUPPORT BRACKET ADJUSTABLE FOR VARYING DEPTHS OF FLOOR CONSTRUCTION.

NOTE: HGT. OF 13" REQUIRED FROM TOP OF INTERCEPTOR TO BOTTOM OF FIXTURE.

© BASED ON INTERCEPTOR IN POSITION #1, ADD 1-1/4" WHEN LOWERING INTERCEPTOR TO SUCCEEDING POSITIONS. INTERCEPTOR SUPPORT BRACKET ADJUSTABLE FOR VARYING DEPTHS OF FLOOR CONSTRUCTION.

Interceptors_08.qxd 5/2/08 3:02 PM Page 215

GREASE INTERCEPTORSGREASE INTERCEPTORS

216

INTE

RCEP

TORS

APPLICATIONFor use in restaurant and institutional kitchens and all types of food handling andprocessing areas where waste water contains fats, oil and grease (FOG). Adequatespace and head room for removal of cover must be available for manual cleaning.Low profile interceptor designed to fit on the floor under equipment in a limited space.

SPECIFICATIONJOSAM 60115A/60117A Series epoxy coated fabricated steel Grease Interceptor,shallow on-floor type, threaded connections, internal air relief, visible double walltrap, removable baffle, gasketed non-skid cover and flow control fitting.

APPLICATIONFor use in restaurant and institutional kitchens and all types of food handling and pro-cessing areas where waste water contains fats, oil and grease (FOG). Semi-automaticdraw-off allows for easy odor and mess free grease removal without opening the cover.Low profile interceptor designed to fit on the floor under equipment in a limited space.

SPECIFICATIONJOSAM 60115-SA Series epoxy coated fabricated steel Grease Interceptor, shallow on-floor type, threaded connections, internal air relief, visible double wall trap, removablebaffle, gasketed non-skid cover, grease recovery cone, flexible hose, grease draw-offvalve and flow control fitting.

60115A/60117A SERIES MANUAL CLEANING, LOW TYPE

60115-SA SERIES SEMI-AUTOMATIC, LOW TYPE

Available Options

Available Options

TYPE NO.

FLOWRATEGPM

GREASECAP.LBS.

PIPESIZE D E F G H LBS.

60115A 20 40 2• 3-1/2 36-3/8 22-5/8 10-1/2 31-5/8 109

60117A 35 70 3 4-1/2 47-3/4 28-5/8 11-1/2 42-5/8 165

-65 Hub Inlet, Spigot Outlet, 2”-66 Hub Inlet, Spigot Outlet, 3”

• -68 3” Inlet and Outlet Available on Standard 2” Size

• 2" sizes normally furnished with 3" x 2" reducing bushings.

TYPE NO. FLOW RATE GPM GREASE CAPACITY LBS. LBS.60115-SA 35 70 124

-65 Hub Inlet, Spigot Outlet, 2”-66 Hub Inlet, Spigot Outlet, 3”

NOTE: HGT. OF 8-1/2" REQUIRED FROM TOP OF INTERCEPTOR TO BOTTOM OF FIXTURE.

Interceptors_08.qxd 5/2/08 3:02 PM Page 216

GREASE INTERCEPTORSGREASE INTERCEPTORS

217

INTERCEPTO

RS

APPLICATIONFor use in restaurant and institutional kitchens and all types of food handling andprocessing areas where waste water contains fats, oil and grease (FOG).

SPECIFICATIONJOSAM 60210A Series epoxy coated fabricated steel Grease Interceptor, high volume,threaded connections, internal air relief, visible double wall trap, removable baffle,gasketed non-skid cover and flow control fitting.

APPLICATIONFor use in restaurant and institutional kitchens and all types of food handling andprocessing areas where waste water contains fats, oil and grease (FOG). Will monitorand alarm facility personnel when interceptor cleaning is required.

SPECIFICATIONJOSAM 60210A-SAP Series epoxy coated fabricated steel Grease Interceptor, high vol-ume, threaded connections, internal air relief, visible double wall trap, removable baf-fle, gasketed non-skid cover, flow control fitting and factory installed wireless Sensingand Alarm Probe (SAP) assembly. Wall-mounted controller is battery powered by a ULlisted 9VDC transformer and has L.E.D. indicators with audible alarm and permanentmemory. Probe assembly is mounted to a bracket for precise placement ensuring accu-rate and reliable readings and transmits to controller via a wireless signal.

60210A SERIES MANUAL CLEANING TYPE

60210A-SAP SERIES with Wireless Sensing and Alarm Probe

t -EXT Extension, 6” Standard. (Specify Extension Height)-60 Anchor Flange-61 Flange and Clamp Device

t -ISI Integrated Solids Interceptor-HD Heavy-Duty Cover-SAP Sensing and Alarm Probe

Available Options

TYPE NO.

FLOWRATEGPM

GREASECAPLBS.

PIPESIZE

ROUGH-INCENTERS LGTH.

EWIDTH

FHGT.

GCOVER

H LBS.C D60213A 150 300 4 27 8 60 39 35 53 72560214A 200 400 5 31-1/2 10 67 42 41-1/2 58 115060215A 250 500 5 35-1/2 10 72 46 45-1/2 63 142560216A 350 700 6 39-1/2 12 80 52 51-1/2 71 180060217A 500 1000 6 43-1/2 12 91 59 55-1/2 82 2300

TYPE NO.

FLOWRATEGPM

GREASECAPLBS.

PIPESIZE

ROUGH-INCENTERS LGTH.

EWIDTH

FHGT.

GCOVER

H LBS.C D60213A-SAP 150 300 4 27 8 60 39 35 53 72760214A-SAP 200 400 5 31-1/2 10 67 42 41-1/2 58 115260215A-SAP 250 500 5 35-1/2 10 72 46 45-1/2 63 142760216A-SAP 350 700 6 39-1/2 12 80 52 51-1/2 71 180260217A-SAP 500 1000 6 43-1/2 12 91 59 55-1/2 82 2302

* 60213A FURNISHED WITH ONE-PIECE COVER.

* 60213A-SAP FURNISHED WITH ONE-PIECE COVER.

t Product Illustration follows.

Interceptors_08.qxd 3/27/08 11:58 AM Page 217

GREASE INTERCEPTORSGREASE INTERCEPTORS

218

INTE

RCEP

TORS

APPLICATIONFor use in large restaurant and institutional kitchens and all types of food handlingand processing areas where waste water contains large amounts of fats, oil andgrease (FOG). Extended top with fixed extension for installations requiring additionalroughing depth from the cover of the interceptor to the inlet and outlet.

SPECIFICATIONJOSAM 60210A-EXT Series epoxy coated fabricated steel Grease Interceptor, high volume,deep roughing, integral extension, threaded connections, internal air relief, visible doublewall trap, removable baffle, gasketed non-skid cover and flow control fitting.

APPLICATIONFor use in large restaurant and institutional kitchens and all types of food handlingand processing areas where waste water contains large amounts of fats, oil andgrease (FOG).

SPECIFICATIONJOSAM 60210A-ISI Series epoxy coated fabricated steel Grease Interceptor, high volume,threaded connections, internal air relief, visible double wall trap, integrated solids inter-ceptor, gasketed non-skid cover and flow control fitting.

60210A-EXT SERIES with Extension

60210A-ISI SERIES with Integrated Solids Interceptor

© DIMENSIONS BASED ON STD. 6" EXTENSION

* 60213A-EXT FURNISHED WITH ONE-PIECE COVER.

* 60213A-ISI FURNISHED WITH ONE-PIECE COVER.

TYPE NO.

FLOWRATEGPM

GREASECAPLBS.

PIPESIZE

ROUGH-INCENTERS LGTH.

EWIDTH

FHGT.G©

COVERH LBS.C D©

60213A-EXT 150 300 4 27 14 60 39 41 53 93560214A-EXT 200 400 5 31-1/2 16 67 42 47-1/2 58 115060215A-EXT 250 500 5 35-1/2 16 72 46 51-1/2 63 142560216A-EXT 350 700 6 39-1/2 18 80 52 57-1/2 71 180060217A-EXT 500 1000 6 43-1/2 18 91 59 61-1/2 82 2300

TYPE NO.

FLOWRATEGPM

GREASECAPLBS.

PIPESIZE

ROUGH-INCENTERS LGTH.

EWIDTH

FHGT.

GCOVER

H LBS.C D60213A-ISI 150 300 4 27 8 60 39 35 53 97560214A-ISI 200 400 5 31-1/2 10 67 42 41-1/2 58 120060215A-ISI 250 500 5 35-1/2 10 72 46 45-1/2 63 147560216A-ISI 350 700 6 39-1/2 12 80 52 51-1/2 71 185060217A-ISI 500 1000 6 43-1/2 12 91 59 55-1/2 82 2400

Interceptors_08.qxd 3/27/08 11:58 AM Page 218

GREASE INTERCEPTORSGREASE INTERCEPTORS

219

INTERCEPTO

RS

APPLICATIONFor use in restaurant and institutional kitchens and all types of food handling andprocessing areas where waste water contains, fats, oil and grease (FOG).

SPECIFICATIONJOSAM 60300A Series fully automatic Grease Recovery Device (GRD) is constructed of 304grade stainless steel with supplemental solids interceptor, removable basket, stainless steeldraw latches, non-adhesive “U” channel gasket, 55 gallon polypropylene reclaim tank withalarm and pump, may be floor mounted, partially recessed, or below grade in vaultedenclosure and is capable of measuring grease, heating congealed grease, and transferringgrease via pump to a remote reclaim tank. The data is then sent to a Nema encased con-troller with an LCD display and LED indicators to provide current system status. The micro-processor records and displays clean cycles on a daily, weekly, monthly and yearly basis.

-23 Remote Monitoring Package(-23 A) Monitoring Plan(-23 B) Monitoring Plan(-23 C) Monitoring Plan

-24 Extended Warranty Package-33 55-Gallon Stainless Steel Reclaim Tank-34 55-Gallon Steel Reclaim Tank

TYPE NO.

FLOWRATEGPM

GREASECAPLBS.

PIPESIZE A B C D E F G LBS.

60306A 25 50 3 24-3/8 9 3-1/2 16 35-1/2 25-5/8 11 22060307A 35 70 3 24-3/8 9 3-1/2 20 40-5/8 31-1/2 15-1/2 34060308A 50 100 3 25-7/8 9 3-1/2 22-1/2 42-3/8 33 17-1/2 42560309A 75 150 4 25-7/8 9 3-1/2 26 56-1/8 46-3/4 21-1/2 70060310A• 100 200 4 35 9 3-1/2 31 67-1/2 58 23 80060311A• 150 300 4 39 9 3-1/2 35 73-3/4 64 27 110060312A• 200 400 6 43 9 3-1/2 41 80-3/4 71 31-1/2 125060313A• 250 500 6 47 9 3-1/2 44-3/4 85-3/4 76 35-1/2 140060314A• 350 700 6 47 9 3-1/2 48 105-1/2 96 39-1/2 152560315A** 500 1000 6 47 9 3-1/2 51 130-7/8 120 44 1650

Available Options

60300A SERIES GI 2000A AUTOMATIC GREASE RECOVERY DEVICE

55-GAL. RECLAIM TANK NOT SHOWN* RECOMMENDED CLEARANCES• INCLUDES EXTERNAL MACERATING PUMP

** UTILIZES TWO PUMPS & RECLAIM TANKS

Interceptors_08.qxd 5/2/08 3:02 PM Page 219

GREASE INTERCEPTORSGREASE INTERCEPTORS

220

INTE

RCEP

TORS

APPLICATIONFor use in restaurant and institutional kitchens and all types of food handling and pro-cessing areas where waste water contains fats, oil and grease (FOG). Additionally, canbe used in service stations, parking garages, car and truck washes and industrial plantswhere discharge water contains oil. Can be used on most manufacturers’ manual orsemi-automatic grease and oil interceptors to monitor and alert facility personnelwhen interceptor cleaning is required.

SPECIFICATIONJOSAM EGOLD-1000 Series Electronic Grease/Oil Level Detector with wall-mountedcontroller, is powered by a UL listed 9 VDC transformer and has L.E.D. indicators withaudible alarm and permanent memory. The probe assembly is mounted to a bracketfor precise placement ensuring accurate and reliable readings.

APPLICATIONFor use in restaurant and institutional kitchens and all types of food handling andprocessing areas where waste water contains fats, oil and grease (FOG). Additionally, canbe used in service stations, parking garages, car and truck washes and industrial plantswhere discharge water contains oil and is intended to be installed in outdoor pre-castinterceptors to monitor and alert facility personnel when interceptor pumping is required.

SPECIFICATIONJOSAM CEGOLD-2000 Series Electronic Grease/Oil Level Detector with wall-mountedcontroller, is powered by a UL listed 9 VDC transformer and has L.E.D. indicators withaudible alarm and permanent memory. The telescoping stainless steel probe assemblyis mounted with brackets on side of interceptor to ensure ease of installation andremoval for maintenance.

EGOLD-1000 SERIES ELECTRONIC GREASE/OIL LEVEL DETECTOR

CEGOLD-2000 SERIES PIT ELECTRONIC GREASE/OIL LEVEL DETECTOR

-23 Remote Monitoring Package(-23 A) Monitoring Plan(-23 B) Monitoring Plan(-23 C) Monitoring Plan

Available Options

-23 Remote Monitoring Package(-23 A) Monitoring Plan(-23 B) Monitoring Plan(-23 C) Monitoring Plan

Available Options

DISTANCE FROM BOTTOM OFINTERCEPTOR TO TOP OF OUTLET RECOMMENDED PROBE ASSEMBLY

12”-18” MA62-10

19”-24” MA62-12

25”-36” MA62-16

37”-and up MA62-21INTERCEPTOR BY JOSAM OR OTHERS

n Longer lengths available on request. n When ordering specify distance from grade to static water line.

DISTANCE FROM GRADE TOSTATIC WATER LINE n RECOMMENDED PROBE ASSEMBLY

22”-48” CO37-04

49”-72” CO37-06

73”-96” CO37-08

97”-120” CO37-10

CONCRETE PIT BY OTHERS

Interceptors_08.qxd 5/2/08 3:02 PM Page 220

221

FLOW CONTROL FITTINGSFLOW CONTROL FITTINGSIN

TERCEPTORS

Flow control fittings are furnished at no extra cost with all JOSAM Interceptors and Separators. These devices govern flow rate to theinterceptor or separator being used, thereby assuring the maximum retention of the material being intercepted.

* All interceptors or separators in this series with a flow rate of 150 G.P.M. or less are shipped with a 60733 & 60734Type Flow Control.

Two Bronze Plugs Furnished for unused Inlet & Outlet to serve as Cleanouts

60710 TYPE

60732 TYPE

60733 & 60734 TYPE

60742 & 60743 TYPE

Essential to Achieving Maximum Efficiency

Interceptor/Separator–Flow Control

This table indicates which series flow control is furnished with the JOSAM interceptors or separators shown.

One of the flow control fittings illustrated on this page will be shipped withevery JOSAM Grease Interceptor or Oil Separator. They were designed aftermany years of tests and field experiments with interceptor installations undervarying conditions and ensure 90% or more grease or oil retention efficiencyof the interceptor.

When consideration isn’t given to the flow rate of the waste water to be han-dled, generally the actual flow rate through the interceptor or separatorexceeds its rated maximum. With such flow rate, the interceptor or separatorwould be overloaded. Retention time within the unit would not be sufficientfor maximum separation. The result would be low efficiency and pollutantsleft in the waste water would pass through the interceptor or separator mak-ing the installation less than effective. When the flow is controlled by use of aJOSAM flow control fitting so that it can never exceed the maximum rating ofthe interceptor or separator, and the unit is cleaned on a regular basis, themaximum pollutant retention efficiency will be achieved and maintained.

All flow controls are provided with an air intake and should be connected tovent stack or vent not lower than the flow level of highest drain serviced orterminated in a return bend at the same elevation outside of building.

FLOW CONTROLS

SeriesFlow Control

Series SeriesFlow Control

Series SeriesFlow Control

Series60100-SA 60730 60110A 60730 60210A* 6071060110-SA 60730 60100H-EXT 60740 60500B 6074060100-SA-RT 60730 60100H-RT 60740 60500B-EXT 6074060100-SA-ET 60730 60100H-ET 60740 60610-EXT* 6071060100H 60740 60210A-EXT* 60710 60610A* 60710

DIMENSIONS IN INCHESType A B C D E F G H J K LBS.60712 2 1-1/4 2-1/2 2 1-1/8 2 3-1/4 3-3/8 6-1/2 3 760713 3 1-1/2 3 2-7/8 1-3/8 2-3/4 4-1/8 4-1/2 8-5/8 4-1/4 1460714 4 2-1/2 3-3/4 4-1/8 1-7/8 4-1/4 6-1/2 6-7/8 12 6-7/8 5260715 5 2-1/2 3-3/4 4-1/8 1-7/8 4-1/4 6-1/2 6-7/8 12 6-7/8 5460716 6 3 4-3/8 5-1/8 2-1/8 4-3/4 7-7/8 8 14-1/4 8 85

A B60742 2-3/8 260743 3-3/8 2-1/2

Interceptors_08.qxd 3/27/08 11:58 AM Page 221

222

OIL SEPARATORSOIL SEPARATORSIN

TERC

EPTO

RS

AN IMPORTANT STEP IN PREVENTING POLLUTION FOR COMMERCIAL AND INDUSTRIAL SERVICE

JOSAM Oil Separators solve the majority of oil and hazardous waste interception and handling problems at the source. Years of research, experimentation and actual field experience

have been applied by JOSAM to the design and development of the oil separators covered in this section. The paramount objective of an oil separator is to intercept and separate oils

from wastewater, and after this has been accomplished, to provide an efficient means of directing the intercepted materials to storage and disposal facilities. JOSAM Oil Separators do

just that with 90% plus retention efficiency. Features of the 60500B and 60610A Series are covered below. The same features with the addition of extended tops are available with

the -EXT option.

Features

SECURED COVERWhite epoxy coating, gasketed air andwatertight bolted non-skid safety pattern top.Suitable as floor plate when set flush with floor.

VENT CONNECTIONVent connection to accommodateatmospheric circulation.

BODYSteel with white epoxy coatinginside and outside.

FLOW CONTROLMaximum oil separation efficiencydepends upon the proper rate of flowthrough the separator. The flow controlregulates flow velocity to prevent taxingthe separator beyond its rated capacityand ensures 90% or more retention effi-ciency. A flow control fitting is furnishedwith each JOSAM Oil Separator and mustbe used as directed.

GRAVITY DRAW-OFFAdjustable skimmer tube with lock nut and packing, when set for operation,provides continuous draw-off of separated oil to storage tank. Draw-off andoil drain line can be connected to either side of separator.

JOSAM Oil Separators are produced in steel to rigid specifications with strict quality control.

60500B Series Shown

OUTLET

INLET

INTERNAL TRAP LEG(not shown)Internal Trap Leg reduces installationspace requirements and allowscleanout access through the removalof the cover

SEDIMENT BUCKET (not shown)Removable, galvanized steel with perforated outlet weir to trap solidsand permit liquid passage. All wastematerial entering separator must passthrough bucket where solids and sediment are retained for removal.

AIR INTAKE OR VENT

Interceptors_08.qxd 3/27/08 11:58 AM Page 222

223

OIL SEPARATORSOIL SEPARATORSIN

TERCEPTORS

SIZING PROCEDURE

The selection of an oil separator depends on the specific features desired and the size of separator required. The sizeof separator required is based on the peak waste water flowthat can be discharged from the fixtures and equipment tobe served.

The peak waste water flow to be handled by the proposedpiping system must be estimated in gallons per minute(GPM). After the required flow has been determined, referto the Oil Separator Selection Table and compare therequired flow rate with the flow rates shown in the table.

NOTE: Larger capacity separators can be fabricated in accordance with specified requirements. Further information is available from your local JOSAM Representative.

EXAMPLE

The car wash piping system in a service station must handle an estimated peak flow of 20 GPM. The OilSeparator Selection Table shows that either the 60505B,the 60505B-EXT or the 60505-EST Separator, all rated at 20 GPM, can fulfill this requirement. It is only necessary to decide which of the three separators is best suited for the proposed installation.

Consider an example for a more extensive piping system:A processing operation has an estimated peak flow rate of300 GPM. The Oil Separator Selection Table shows that the 60616A, the 60616A-EXT or the 60616-EST Separator,rated at 350 GPM, can handle the requirement. Sizing ahorizontal waste line depends on the specific pipe materialand the required pipe slope. The Horizontal Pipe Flow Tableindicates the approximate GPM flow rates at various slopesthat can be handled by cast iron or galvanized steel pipe.

Sizing and Selection

OIL SEPARATOR SELECTION TABLE

SeriesFlowRateGPM

Inlet &Outlet Size

(Inches)

60503B, 60503B-EXT, 60503-EST 10 2

60504B, 60504B-EXT, 60504-EST 15 2

60505B, 60505B-EXT, 60505-EST 20 3

60506B, 60506B-EXT, 60506-EST 25 3

60507B, 60507B-EXT, 60507-EST 35 3

60508B, 60508B-EXT, 60508-EST 50 3

60611A, 60611A-EXT, 60611-EST 75 3

60612A, 60612A-EXT, 60612-EST 100 4

60613A, 60613A-EXT, 60613-EST 150 4

60614A, 60614A-EXT, 60614-EST 200 5

60615A, 60615A-EXT, 60615-EST 250 5

60616A, 60616A-EXT, 60616-EST 350 6

60617A, 60617A-EXT, 60617-EST 500 6

HORIZONTAL PIPE FLOW, GPM

Pipe Size(Inches)

Pipe Slope(Inches per Foot)

1/8 1/4 1/2

2 12 16 24

3 34 48 69

4 78 110 157

5 139 197 278

6 223 315 446

Interceptors_08.qxd 3/27/08 11:58 AM Page 223

224

OIL SEPARATORSOIL SEPARATORSIN

TERC

EPTO

RS

Installations and diagrams below show various components and suggested methods used when installing JOSAM Oil Separators.All installations are subject to government and local code requirements.

Gravity Draw-Off for Oil Separator

GRAVITY DRAW-OFFEvery JOSAM Oil Separator is equipped with an internalgravity draw-off assembly having an adjustable skimmertube and a threaded pipe connection through the side wallof separator body. This assembly can be mounted on eitherside to accommodate installation requirements. The pipingto oil storage tank is connected to the draw-off. Typicalinstallations are shown below.

SETTING THE GRAVITY DRAW-OFF TUBEAfter separator is completely installed and ready for operation,run clean water through the unit at the anticipated operationalflow rate and mark the operating water level. Set skimmertube with top 1/8" above operating water level. During normaloperation a film of oil will be on the water surface with allexcess oil skimmed and drawn-off to a storage facility. Whenthe tube is properly set water will not be drawn off with oil.

Typical arrangement of separator, draw-off piping, venting andoil storage facility.

Oil separator recessed flush with floor, servicing a floor drain. Flowcontrol is installed with cleanouts to facilitate servicing.

Oil separator and flow control installed in pit, servicing a battery of floor drains.

Typical Installations

Interceptors_08.qxd 3/27/08 11:58 AM Page 224

APPLICATIONFor use in service stations, parking garages, car and truck washes and industrialplants where discharged water contains oil, sediment and other volatile liquids.Separator collects oil and conveniently permits the collected oil to be drained to astorage tank by means of an adjustable gravity draw-off connection. Sediment anddebris are collected in a sediment bucket that can be periodically removed. Anextended top with fixed extension is supplied for installations requiring additionalroughing depth from center of inlet and outlet to finished floor height.

SPECIFICATIONJOSAM 60500B-EXT Series fabricated steel Oil Separator, epoxy coated inside andoutside, threaded connections, deep roughing, integral extension, internal trap,sediment bucket, two vent connections on each side, gasketed non-skid cover andflow control fitting.

OIL SEPARATORSOIL SEPARATORS

225

INTERCEPTO

RS

APPLICATIONFor use in service stations, parking garages, car and truck washes and industrialplants where discharged water contains oil, sediment and other volatile liquids.Separator collects oil and conveniently permits the collected oil to be drained to astorage tank by means of an adjustable gravity draw-off connection. Sediment anddebris are collected in a sediment bucket that can be periodically removed.

SPECIFICATIONJOSAM 60500B Series fabricated steel Oil Separator, epoxy coated inside and outside,threaded connections, internal trap, sediment bucket, two vent connections on eachside, gasketed non-skid cover and flow control fitting.

60500B SERIES DRAW-OFF, GRAVITY TYPE

t -EXT Extension, 6” Standard (Specify Extension Height)-60 Anchor Flange-61 Flange and Clamp Device-HD Heavy-Duty Cover

• 3” sizes normally furnished with 4” x 3” reducing bushings.

• 3” sizes normally furnished with 4” x 3” reducing bushings.

Available Options

TYPENO.

FLOWRATEGPM

PIPESIZE

ROUGH-INCENTERS LGTH.

EWIDTH

FHGT.

G

VENT & DRAW OFFROUGH-IN

LBS.C D M R S

60503B 10 2 10-1/2 4-1/8 15-7/16 12-3/8 14-5/8 6-5/8 2-7/8 8-1/2 5560504B 15 2 12-3/4 3-3/8 18-3/16 14-1/2 16-1/8 8 2-5/8 10-3/4 7260505B 20 3• 14-5/8 4-3/8 19-15/16 16-3/8 19 8-7/8 2-3/4 12 8560506B 25 3• 16 4 21-11/16 17-1/2 20 9-3/4 2-3/4 13-1/2 10560507B 35 3• 16-3/4 4-7/8 25-5/16 19-1/4 21-5/8 11-9/16 2-3/4 14-1/4 13060508B 50 3• 18-1/2 6-1/4 28-11/16 21-1/2 24-3/4 13-1/4 3 16 155

60500B-EXT SERIES with Extension

TYPENO.

FLOWRATEGPM

PIPESIZE

ROUGH-INCENTERS LGTH.

EWIDTH

FHGT.G©

VENT & DRAW OFFROUGH-IN

LBS.C D© M R S

60503B-EXT 10 2 10-1/2 10-1/8 15-7/16 12-3/8 20-5/8 6-5/8 2-7/8 8-1/2 5560504B-EXT 15 2 12-3/4 9-3/8 18-3/16 14-1/2 22-1/8 8 2-5/8 10-3/4 7260505B-EXT 20 3• 14-5/8 10-3/8 19-15/16 16-3/8 25 8-7/8 2-3/4 12 8560506B-EXT 25 3• 16 10 21-11/16 17-1/2 26 9-3/4 2-3/4 13-1/2 10560507B-EXT 35 3• 16-3/4 10-7/8 25-5/16 19-1/4 27-5/8 11-9/16 2-3/4 14-1/4 13060508B-EXT 50 3• 18-1/2 12-1/4 28-11/16 21-1/2 30-3/4 13-1/4 3 16 155

© DIMENSIONS BASED ON STD. 6" EXTENSION.

t Product Illustration follows.

Interceptors_08.qxd 5/2/08 4:26 PM Page 225

OIL SEPARATORSOIL SEPARATORS

226

INTE

RCEP

TORS

APPLICATIONFor use in service stations, parking garages, car and truck washes, industrial plants andelevator pits where discharged water contains oil, sediment and other volatile liquids.Separator collects oil and conveniently permits the collected oil to be drained directly to the integral storage tank by means of an adjustable gravity draw-off connection.Sediment and debris are collected in a sediment bucket that can be periodically removed.

SPECIFICATIONJOSAM 60500-EST Series fabricated Oil Separator, epoxy coated inside and outside,flush-with-floor type with oil storage tank, threaded connections, flat bottom, visibledouble-wall trap, sediment bucket, gasketed cover, check valve and flow control fitting.

60500-EST SERIES with External Storage Tank

Available Options-EXT Extension, 8” Standard, Specify Extension Height-HD Heavy-Duty Cover -19 Reclaim Tank Alarm-60 Anchor Flange-61 Flange and Clamp Device

TYPE FLOWRATE

TANK(GAL.)

PIPESIZE A B C D E F

60503-EST-50 10 50 2 33-1/2 20 9-3/8 4 19-3/8 12-1/4

60504-EST-50 15 50 2 33-1/2 20 11-1/2 4-5/8 22-1/8 14

60505-EST-50 20 50 3• 33-1/2 20 13 4-3/8 24-3/4 16

60506-EST-50 25 50 3• 33-1/2 20 14-1/2 4 26-3/8 17

60506-EST-100 25 100 3• 38 24 14-1/2 4 26-3/8 17

60507-EST-50 35 50 3• 33-1/2 20 15-1/2 4-7/8 30 19-3/4

60507-EST-100 35 100 3• 38 24 15-1/2 4-7/8 30 19-3/4

60508-EST-50 50 50 3• 33-1/2 20 17-1/2 6 33-3/8 22

60508-EST-100 50 100 3• 38 24 17-1/2 6 33-3/8 22

TYPE G H L M N P Q S V

60503-EST-50 13-3/8 28 34-1/4 3-3/4 5 10 22 6 30

60504-EST-50 16-1/8 28 36 4-1/2 7-1/4 12-1/2 22 7-3/4 30

60505-EST-50 17-3/8 28 38 6-1/8 8 15-3/4 22 8-1/4 30

60506-EST-50 18-1/2 28 39 5-1/4 8 16-1/2 22 9-1/4 30

60506-EST-100 18-1/2 36 43 5-1/4 8 16-1/2 26 9-1/4 38

60507-EST-50 20-3/8 28 41-3/4 6-1/2 8 19 22 10 30

60507-EST-100 20-3/8 36 45-3/4 6-1/2 8 19 26 10 38

60508-EST-50 23-1/2 28 44 7 8 21-1/2 22 11-1/4 30

60508-EST-100 23-1/2 36 48 7 8 21-1/2 26 11-1/4 38

• 3” sizes normally furnished with 4” x 3” reducing bushings.

Interceptors_08.qxd 5/2/08 3:02 PM Page 226

OIL SEPARATORSOIL SEPARATORS

227

INTERCEPTO

RS

t Product Illustration follows.

APPLICATIONFor use in large service stations, parking garages, car and truck washes and industrialplants where discharged water contains high volumes of waste laden with oil, sedi-ment and other volatile liquids. Separator collects oil and conveniently permits thecollected oil to be drained to a storage tank by means of an adjustable gravity draw-off connection. Sediment and debris are collected in a sediment bucket that can beperiodically removed.

SPECIFICATIONJOSAM 60610A Series fabricated steel Oil Separator, epoxy coated inside and outside,high volume, threaded connections, visible double wall trap and sediment bucket,adjustable gravity draw-off either side, two vent connections on each side, gasketednon-skid cover and flow control fitting.

60610A SERIES DRAW-OFF TYPE

t -EXT Extension, 6” Standard (Specify Extension Height)-60 Anchor Flange-61 Flange and Clamp Device-HD Heavy-Duty Cover

Available Options

TYPENO.

FLOWRATEGPM

PIPESIZE

ROUGH-INCENTERS LGTH.

EWIDTH

FHGT.

GCOVER

H

VENT & DRAW OFFROUGH-IN

LBS.C D M N P S

60611A 75 3 21 6 46-1/4 31 27 41 8-1/4 12-1/2 10-1/4 13-1/2 450

60612A 100 4 23 8 54 35 31 47 9-1/2 14-1/2 12-1/2 15-1/4 575

60613A 150 4 27 8 60 39 35 53 10-1/2 16-1/2 14-1/2 19-1/4 750

60614A 200 5 31-1/2 10 67 42 41-1/2 58 11-1/2 18-1/8 16 26-1/4 1200

60615A 250 5 35-1/2 10 72 46 45-1/2 63 12-1/2 20-1/4 17-1/2 29-3/4 1475

60616A 350 6 39-1/2 12 80 52 51-1/2 71 13-1/2 23 19-3/4 34-1/4 1875

60617A 500 6 43-1/2 12 91 59 55-1/2 82 16 27 23 38-1/4 2575

60610A-EXT SERIES with ExtensionAPPLICATION

For use in large service stations, parking garages, car and truck washes and industrialplants where discharged water contains high volumes of waste laden with oil, sedi-ment and other volatile liquids. Separator collects oil and conveniently permits the col-lected oil to be drained to a storage tank by means of an adjustable gravity draw-offconnection. Sediment and debris are collected in a sediment bucket that can be peri-odically removed. An extended top with fixed extension is supplied for installationsrequiring additional roughing depth from center of inlet and outlet to finished floorheight.

SPECIFICATIONJOSAM 60610A-EXT Series fabricated steel Oil Separator, epoxy coated inside andoutside, high volume, deep roughing, integral extension, threaded connections, visibledouble wall trap, sediment bucket, adjustable gravity draw-off either side, two ventconnections on each side, gasketed non-skid cover and flow control fitting.

TYPENO.

FLOWRATEGPM

PIPESIZE

ROUGH-INCENTERS LGTH.

EWIDTH

FHGT.G©

COVERH

VENT & DRAW OFFROUGH-IN

LBS.C D© M N P S

60611A-EXT 75 3 21 12 46-1/4 31 33 41 8-1/4 12-1/2 10-1/4 13-1/2 600

60612A-EXT 100 4 23 14 54 35 37 47 9-1/2 14-1/2 12-1/2 15-1/4 750

60613A-EXT 150 4 27 14 60 39 41 53 10-1/2 16-1/2 14-1/2 19-1/4 975

60614A-EXT 200 5 31-1/2 16 67 42 47-1/2 58 11-1/2 18-1/8 16 26-1/4 1200

60615A-EXT 250 5 35-1/2 16 72 46 51-1/2 63 12-1/2 20-1/4 17-1/2 29-3/4 1475

60616A-EXT 350 6 39-1/2 18 80 52 57-1/2 71 13-1/2 23 19-3/4 34-1/4 1875

60617A-EXT 500 6 43-1/2 18 91 59 61-1/2 82 16 27 23 38-1/4 2575

© DIMENSIONS BASED ON STD. 6” EXTENSION* 60611A-EXT, 60612A-EXT & 60613A-EXT ARE FURNISHED WITH ONE-PIECE COVER.

* 60611A, 60612A & 60613A ARE FURNISHED WITH ONE-PIECE COVER.

Interceptors_08.qxd 3/27/08 11:59 AM Page 227

OIL SEPARATORSOIL SEPARATORS

228

INTE

RCEP

TORS

APPLICATIONFor use in service stations, parking garages, car and truck washes, industrial plants andelevator pits where discharged water contains high volumes of waste laden with oil, sedi-ment and other volatile liquids. Separator collects oil and conveniently permits the col-lected oil to be drained directly to the integral storage tank by means of an adjustablegravity draw-off connection. Sediment and debris are collected in a sediment bucket thatcan be periodically removed.

SPECIFICATIONJOSAM 60610-EST Series fabricated Oil Separator, epoxy coated inside and outside,flush-with-floor type with oil storage tank, threaded connections, flat bottom, visibledouble-wall trap, sediment bucket, gasketed cover, check valve and flow control fitting.

60610-EST SERIES with External Storage Tank

Available Options-EXT Extension, 8” Standard, Specify Extension Height-HD Heavy-Duty Cover -19 Reclaim Tank Alarm-60 Anchor Flange-61 Flange and Clamp Device

TYPE FLOWRATE

TANK(GAL.)

PIPESIZE D E F G H J N T V W LBS.

60611-EST 75 100 3 8 46 31 29 41 4 12 37 24 59 1200

60612-EST 100 250 4 8 54 35 31 47 5 14 48 35 70 1500

60613-EST 150 250 4 10 60 39 37 53 5 16 45 35 74 2000

60614-EST 200 250 5 15 67 42 49 54 6 18 48 35 77 2400

60615-EST 250 500 5 15 72 46 51 63 6 20 60 45 91 3000

60616-EST 350 500 6 15 80 52 55 71 6 23 56 45 97 3800

60617-EST 500 500 6 26 91 59 70 83 6 27 66 45 104 5200* 60611-EST, 61612-EST and 61613-EST FURNISHED WITH ONE-PIECE COVER.

Interceptors_08.qxd 4/9/08 9:32 AM Page 228

OIL SEPARATORSOIL SEPARATORS

229

INTERCEPTO

RS

APPLICATIONFor use in service stations, parking garages, car and truck washes and industrial plantswhere discharged water contains oil, sediment and other volatile liquids. Sediment anddebris are collected in the sediment pan and removable bucket, which are accessible byremoving the top grate. Oil and grease are trapped in the unit and may be skimmed offperiodically.

SPECIFICATIONJOSAM 60810 Series steel Oil Sediment Interceptor with acid-resisting coating, threadedconnection, flat bottom, visible double wall trap, removable sediment bucket, primaryand secondary screens and medium-duty cast iron grate(s).

60810 SERIES OIL SEDIMENT INTERCEPTOR

TYPE NO.

PIPESIZE

GRATEFREEAREA

(SQ. IN.)NO. OFGRATES

SLUDGECAP

(LBS.) E F G H LBS.60816 2 54 1 12 17-1/2 12-1/8 15 12-1/8 6060817 4 112 1 60 29-7/8 12-1/2 25 24-1/2 17560818 4 224 2 100 29-7/8 24-1/2 25 24-1/2 28060819 4 336 3 200 41-7/8 24-1/2 35 36-1/2 360

SLOT WIDTH 1/2”

Interceptors_08.qxd 3/27/08 11:59 AM Page 229

SOLIDS INTERCEPTORSSOLIDS INTERCEPTORS

230

INTE

RCEP

TORS

APPLICATIONFor use on the lavatory or sink in barber shops, beauty salons, dormitories and motelswhere hair, lint and other solids are commonly encountered. May also serve as ameans of retrieving rings, other valuables or dental grindings, which have beendropped into the sink or lavatory. Cleaning is accomplished by removal of bottomcover and basket.

SPECIFICATIONJOSAM 61000 Series Nikaloy Solids Interceptor, bottom access, fixture trap type, slipjoint inlet, 1-1/2" threaded side outlet, gasketed cover and removable perforatedstainless steel basket.

APPLICATIONFor use as a means of collecting solids such as metal chips, plaster and grindings indental offices, jewelry and optical shops or similar establishments where the unit canbe mounted directly under the sink to recover precious metals as well as interceptharmful debris. Cleaning is accomplished by removal of top cover and basket.

SPECIFICATIONJOSAM 61030 Series coated cast iron Solids Interceptor, top access, fixture trap type,threaded connections, gasketed cover, removable galvanized steel basket and stainlesssteel screen.

61000 SERIES BOTTOM ACCESS FIXTURE TRAP TYPE

61030 SERIES TOP ACCESS FIXTURE TRAP TYPE

-26 Cast Aluminum-30 Acid-Resisting Inside and Outside

TYPE NO. PIPE SIZE LBS.61031-1/2 1-1/2 961032 2 9

TYPE NO. INLET A OUTLET B LBS.61001-1/4 1-1/4 1-1/2 661001-1/2 1-1/2 1-1/2 6

Available Options-1 Painted Cast Iron-3 Polished Bronze-30 Acid-Resisting C.I. Inside and Outside

NOTE: 6" MIN. CLEARANCE REQUIRED BELOW COVER FOR REMOVAL OF BASKET.

Available Options

q MIN. HEIGHT REQUIRED FOR REMOVAL OF BUCKET AND SCREEN.

Interceptors_08.qxd 5/2/08 3:04 PM Page 230

SOLIDS INTERCEPTORSSOLIDS INTERCEPTORS

231

INTERCEPTO

RS

APPLICATIONFor use as a means of collecting large amounts of solids such as metal chips, plasterand grindings in dental offices, hospitals and optical shops or similar establishmentswhere the unit can be mounted on the floor under the sink to recover precious metalsas well as intercept harmful debris. Cleaning is accomplished by removal of top coverand basket.

SPECIFICATIONJOSAM 61040A Series steel Solids Interceptor with acid-resisting coating, top access,on-floor trap type, with 2" threaded connections, side outlet, gasketed non-skid cover,removable galvanized steel basket and stainless steel screens.

-EXT Extension, 6” Standard (Specify Extension Height)-16 Monel Screens

APPLICATIONFor use as a means of collecting solid waste materials, hair, lint and foreign particlesahead of swimming pool filters and processing devices or commercial laundry equip-ment. Cleaning is accomplished in minimal time by removal of top cover secured withswing bolts and basket.

SPECIFICATIONJOSAM 61070 Series cast iron Solids Interceptor with acid-resisting coating, top access,in-line type, threaded connections, 2" threaded drain or blow-off connection, removableperforated copper basket with conical solid bottom, gasketed cast iron support rim andgasketed cover seated on basket support rim secured with hex head bolts.

Available Options-4 Galvanized Cast Iron Parts-15 Stainless Steel Basket-86 Flat Bottom Basket

BASKET FREE AREA85.0 SQ. IN.

61070 SERIES TOP ACCESS IN-LINE TYPE

61040A SERIES TOP ACCESS ON-FLOOR TRAP TYPE

Available Options

TYPE NO. PIPE SIZE D E G LBS.61042A 2 3 1/2 31 16 5/8 5461043A 3 4 1/2 32 17 5/8 6061044A 4 5 1/2 33 18 5/8 55

TYPE NO. PIPE SIZE LBS.61072 2 6561073 3 6561074 4 65

n MIN. HGT. REQUIRED FOR REMOVAL OF SOLIDS BASKET.ADD EXT. HGT. TO MIN. HGT. REQUIRED IF FURNISHED WITH EXT.

Interceptors_08.qxd 5/2/08 3:02 PM Page 231

SOLIDS INTERCEPTORSSOLIDS INTERCEPTORS

232

INTE

RCEP

TORS

APPLICATIONFor use as a means of collecting very large quantities of solid waste materials, hair,lint and foreign particles ahead of swimming pool filters and processing devices orcommercial laundry equipment. Cleaning is accomplished in minimal time by removalof top cover secured with gasketed compression yoke and basket.

SPECIFICATIONJOSAM 61080 Series cast iron Solids Interceptor with acid-resisting coating, top access,in-line type, threaded connections, 2" threaded drain or blow-off connection, removableperforated copper basket with conical solid bottom, gasketed cast iron support rim andgasketed cover seated on basket. Support rim secured with hex head bolts.

APPLICATIONFor use as a means of collecting very large quantities of solid waste materials, hair,lint and foreign particles ahead of swimming pool filters and processing devices orcommercial laundry equipment. Cleaning is accomplished through removal of non-skid cover and basket.

SPECIFICATIONJOSAM 61800 Series Lint Interceptor with acid-resisting coating, non-skid cover, gal-vanized steel bucket with stainless steel screens and threaded connections.

61080 SERIES TOP ACCESS IN-LINE TYPE

61800 SERIES LINT INTERCEPTOR

-4 Galvanized Cast Iron Parts-15 Stainless Steel Basket-86 Flat Bottom Basket

-EXT Extension, 6” Standard (Specify Extension Height)

Available Options

TYPE NO. PIPE SIZE LBS.61084 4 20261085 5 20261086 6 212

Available Options

TYPE NO.

FLOWRATEGPM

MAX. NO.OF

WASHERSPIPESIZE C D E F G LBS.

61805 70 7 3 12 6 20 17 18 9061806 200 20 4 14 6 22 18 20 12061807 300 30 6 16 6 25 20 22 19061808 400 40 6 18 6 29 22 24 220

BASKET FREE AREA250 SQ. IN.

Interceptors_08.qxd 5/2/08 6:14 PM Page 232

233

BACKWATER VALVESBACKWATER VALVESBW

V,HYD

RAN

TS & SH

OCKS

A SAFEGUARD AGAINST WATER DAMAGEAnyone who has ever experienced flooding caused by a reversal of sewage flow never wants to be confronted with a reoccurrence.Damage is extensive and generally uninsurable. Backwater and its attendant problems must therefore be seriously considered in termsof adequate control and prevention by individuals responsible for the design and construction of buildings. To overlook the possibilityof backwater or underestimate the destruction and unsanitary conditions that will result from uncontrolled backwater would be a gravemistake. JOSAM Backwater Valves provide the flood control that is required.

Features

1. SWING-CHECK

The most frequently used backwater valve is the swing-check,rotating, self-cleaning disc type. This valve is normally fur-nished with the disc installed in the closed position to preventcirculation of sewer gas. If desired, the disc can be assembledto hang open to permit circulation of air by moving the hingepin to its alternate position.

2. SHEAR-GATE

This manually operated shear-gate valve is spade shaped tocut through any sewage debris that may become lodged onthe seating surface providing positive assurance of completeclosing against backwater.

3. BALL-FLOAT CHECK

This type of backwater valve is incorporated in certain floor drains and traps. It is also used as auxiliary equipment for bottomoutlet floor drains to provide independent backflow protection.The ball-float seals against the ring seat with backflow.

4. COMBINATION SHEAR-GATE AND SWING-CHECK VALVE

This combination valve provides dual protection against backflow. The automatic swing-check responds with instant closure when backflow starts. During emergency periods, whena serious backwater condition exists or is expected, or when the building drainage system is to be shut down, the manuallyoperated shear-gate is closed until the building drain line can be used again. The shear-gate valve is kept open when thebuilding drainage system is in use.

This type of backwater valve is intended primarily for installation in new construction.

JOSAM OFFERS FOUR BASIC TYPES OF ASSEMBLIES

Normal Position

Closed with

No Flow

Flow Position

Variable Depending

on Discharge Flow

Backflow Position

Instant Closing with

Backflow

Backwater Valves_08.qxd 3/27/08 12:08 PM Page 233

234

BACKWATER VALVESBACKWATER VALVESBW

V,H

YDRA

NTS

& S

HO

CKS

EXAMPLE: Series No. 67100A Type No. 67103A

67103A -Z -5

Outlet Size 3"

Outlet Type, No Hub Spigot Outlet

Optional Material, Galvanized Cast Iron Parts

EXAMPLE: Series No. 67500 Type No. 67504

67504 -10

Outlet Size

Option, Threaded Bronze Cover

How to OrderUnless optional materials are specified, standard material shown in Specification will be provided. Last digit indicates outlet size.Series 67100A Backwater Valve is for use with any 4" or 6" No-Hub Drain.

Available only in hub and spigot connections.

SWING-CHECK TYPE67500Hub & Spigot Connections

Page 237

67600Hub & Spigot Connections

Page 237

67650Pit Type, Spigot Connection

Page 238

67720Terminal Type, Hub Connection

Page 238

67800Terminal Type, Hub Connection

Page 239

BALL FLOAT SWING-CHECK TYPE67100A

Page 235

67360Straight Through Shear Gate

Page 235

67360-DHStraight Through Shear Gate, Double Hub

Page 236

67400No-Hub Connection

Page 236

BACKWATER VALVES • Pictorial Selection GuideBACKWATER VALVES • Pictorial Selection Guide

Backwater Valves_08.qxd 3/27/08 12:08 PM Page 234

BACKWATER VALVESBACKWATER VALVES

235

BWV,H

YDRA

NTS &

SHO

CKS

APPLICATIONFor use with any 4" or 6" No-Hub floor drain where protection from backflow maybe necessary.

SPECIFICATIONJOSAM 67100A Series coated cast iron Backwater Valve, plastic ball-float, elastomerseat, bronze cage and bottom outlet spigot connection.

APPLICATIONFor use in main or branch drain lines to protect basements and lower areas fromsewer back up. Flapper type backwater valve provides continuous protection againstsewage backflow into building. Manually closed shear-gate valve provides additionalcomplete "closure" protection during emergency storm conditions or when building iscompletely shut down.

SPECIFICATIONJOSAM 67360 Series coated cast iron combination Backwater Valve, straight-throughtype, bronze swing-check assembly, bronze manually operated shear-gate with non-risingstem and hub and spigot connections.

67100A SERIES BALL-FLOAT ADAPTER TYPE

67360 SERIES SHEAR-GATE & SWING-CHECK TYPE

t Product Illustration follows.

-5 Galvanized Cast Iron Parts-35 1/2" Primer Tap

t -DH Double Hub-15 Open Flap-28 12" Cast Iron Extension and Stem-29 24" Cast Iron Extension and Stem

Available Options

Available Options

STRAIGHT-THROUGH TYPEFOR EXISTINGINSTALLATIONS

TYPE NO. PIPE SIZE B D LBS.67102A 2 4 6-5/8 667103A 3 4 7-7/8 767104A 4 4 6-1/8 867106A 6 6 10 23

TYPE NO. PIPE SIZE B C E LBS.67363 3 8 12 17-1/2 8067364 4 8 12 17-1/2 8067365 5 10-1/2 14-1/2 19-1/2 12067366 6 10-1/2 14-1/2 19-1/2 120

NOTE: SWING-CHECK VALVE NORMALLY HANGS IN CLOSED POSITION, BUT CAN BE SET TO HANG OPEN.

Backwater Valves_08.qxd 3/27/08 12:08 PM Page 235

APPLICATIONFor use in main or branch drain lines to protect basements and lower areas fromsewer back up. Flapper type backwater valve provides continuous protection againstsewage backflow into building.

SPECIFICATIONJOSAM 67400 Series coated cast iron Backwater Valve, offset type, bronze fixedswing-check assembly, bolted gasketed cover and no-hub connections.

BACKWATER VALVESBACKWATER VALVES

236

BWV,

HYD

RAN

TS&

SHO

CKS

APPLICATIONFor use in main or branch drain lines to protect basements and lower areas fromsewer back up. Flapper type backwater valve provides continuous protection againstsewage backflow into building. Manually closed shear-gate valve provides additionalcomplete "closure" protection during emergency storm conditions or when buildingis completely shut down.

SPECIFICATIONJOSAM 67360-DH Series coated cast iron combination Backwater Valve, straight-through type, bronze swing-check assembly, bronze manually operated shear-gatewith non-rising stem and hub connections.

67360-DH SERIES with -DH Double Hub

67400 SERIES NO-HUB SWING-CHECK TYPE

STRAIGHT-THROUGH TYPEFOR EXISTINGINSTALLATIONS

BOLTED COVER,OFFSET TYPE

NOTE: SWING-CHECK VALVE NORMALLY HANGS IN CLOSED POSITION, BUT CAN BE SET TO HANG OPEN.

TYPE NO. PIPE SIZE B C D LBS.67363-DH 3 8 12 16 8067364-DH 4 8 12 16 8067365-DH 5 10-1/2 14-1/2 16 12067366-DH 6 10-1/2 14-1/2 16 120

TYPE NO. PIPE SIZE B C D E F LBS.67402 2 3-5/8 5-1/4 4 8 1/2 1067403 3 4 6 5 10 1/2 1367404 4 4-3/4 7 6 12 1/2 2167406 6 5-3/4 9 6 12 5/8 38

Backwater Valves_08.qxd 5/2/08 1:09 PM Page 236

BACKWATER VALVESBACKWATER VALVES

237

BWV,H

YDRA

NTS

&SH

OCKS

TYPE NO.

PIPE SIZE B D E F H J K M LBS.

67502 2 6-7/8 6-1/4 7 5 1-1/2 6-1/2 12 5-1/4 2567503 3 7-7/8 7-1/2 10 5-3/4 1-1/4 9 15-3/4 6-3/4 3067504 4 9 8-1/8 10-3/4 6-3/8 1-1/2 9 17-1/8 7-1/4 4067506 6 11-1/4 10 11-3/4 7-3/4 1-3/4 10-3/4 19-1/2 8-3/4 6567508 8 13-3/4 11-3/4 12-1/2 7-3/4 2-1/4 11 20-1/4 10 79

APPLICATIONFor use in main or branch drain lines to protect basements and lower areas fromsewer back up. Flapper type backwater valve provides continuous protection againstsewage backflow into building.

SPECIFICATIONJOSAM 67500 Series coated cast iron Backwater Valve, offset type, bronze swing-check assembly, bolted gasketed cover and hub and spigot connections.

APPLICATIONFor use in main or branch drain lines to protect basements and lower areas fromsewer back up. Flapper type backwater valve provides continuous protection againstsewage backflow into building.

SPECIFICATIONJOSAM 67600 Series coated cast iron Backwater Valve, offset type, bronze swing-check assembly, bolted gasketed cover and hub and spigot connections.

* -10 Threaded Bronze Cover 3"-8"-15 Open Flap-30 2" Auxiliary Inlet with Bronze Plug

* For extension, use –10 option with hub and spigot extension pipe by others.

-15 Open Flap

67500 SERIES HUB & SPIGOT, SWING-CHECK TYPE

67600 SERIES HUB & SPIGOT, SWING-CHECK TYPE

Available Options

Available Option

BOLTED COVER,OFFSET TYPE

BOLTED COVER,OFFSET TYPE

NOTE: SWING-CHECK VALVE NORMALLY HANGS IN CLOSED POSITION, BUT CAN BE SET TO HANG OPEN.

TYPENO.

PIPESIZE OFFSET C D E F G LBS.

67610 10 2 8-1/2 10-1/2 23 10-1/2 13 21667612 12 2 9-1/4 11-1/4 25-3/4 12 15 277

NOTE: SWING-CHECK VALVE NORMALLY HANGS IN CLOSED POSITION, BUT CAN BE SET TO HANG OPEN.

HUB AND SPIGOT DIM. ARE IN ACCORDANCE WITH E.H.C.I. SOIL PIPE STANDARDS.

Backwater Valves_08.qxd 4/22/08 6:46 PM Page 237

BACKWATER VALVESBACKWATER VALVES

238

BWV,

HYD

RAN

TS &

SH

OCK

S

APPLICATIONFor use at the base of walls in pits or pools, where elevation is limited, requiring avertical inlet drain with a back outlet and a flapper type backwater valve to safe-guard pit equipment or pool from backflow contamination.

SPECIFICATIONJOSAM 67650 Series coated cast iron Backwater Valve, pit type, bronze swing-checkassembly, vertical inlet grate and spigot connection.

APPLICATIONFor use at the termination of drain lines which discharge into manholes and basins orthrough retaining walls to protect the lines from backflow and discourage theentrance of vermin.

SPECIFICATIONJOSAM 67720 Series coated cast iron Backwater Valve, terminal type, bronze swing-check assembly and hub connection.

67650 SERIES COMBINED DRAIN/SWING-CHECK TYPE

67720 SERIES HUB INLET, SWING-CHECK TYPE

-1 Satin Finish Nikaloy Face-2 Satin Finish Bronze Face-5 Galvanized Cast Iron Parts-25 Flashing Clamp Device-VP Secured Face, Vandal-Proof Screws-LBV Less Backwater Valve

-15 Open Flap

Available Options

Available Options

SECURED COVER,PIT TYPE

TERMINAL TYPE

NOTE: SWING-CHECK VALVE NORMALLY HANGS IN CLOSED POSITION, BUT CAN BE SET TO HANG OPEN.

TYPENO.

PIPESIZE B X B1 C X C1 D E F

FREEAREASQ. IN. LBS.

67653 3 9-5/16 x 7-5/8 12-3/4 x 10-7/8 5-1/8 1-1/8 13 19 4067654 4 9-5/16 x 7-5/8 12-3/4 x 10-7/8 5-1/8 1-1/8 13 19 4067656 6 11 x 8-7/8 14-3/4 x 12-3/8 5-1/2 1-1/8 14 22 52

TYPE NO. PIPE SIZE B LBS.67723 3 5 567724 4 6-1/4 7

Backwater Valves_08.qxd 3/27/08 12:08 PM Page 238

BACKWATER VALVESBACKWATER VALVES

239

BWV,H

YDRA

NTS &

SHO

CKS

APPLICATIONFor use at the termination of drain lines which discharge into manholes and basins orthrough retaining walls to protect the lines from backflow and discourage theentrance of vermin.

SPECIFICATIONJOSAM 67800 Series coated cast iron Backwater Valve, terminal type, bronze swing-check assembly with bolted cast iron seat and hub connection.

Available Options-4 Bronze Seat-15 Open Flap

TYPE NO. PIPE SIZE B C D E F LBS.67806 6 8-1/8 9-7/8 7-3/4 2-1/8 7/8 2067808 8 10-1/8 15-3/4 11-1/2 4-1/4 1-1/4 82

TERMINAL TYPE

67800 SERIES HUB INLET, SWING-CHECK TYPE

NOTE: SWING-CHECK VALVE NORMALLY HANGS INCLOSED POSITION, BUT CAN BE SET TO HANG OPEN.

* 67806 VALVE SEAT IS FLANGED, GASKETED AND BOLTED.67808 VALVE SEAT IS JOINED TO HUB INLET BY THREADS.

Backwater Valves_08.qxd 3/27/08 12:08 PM Page 239

240

HYDRANTSHYDRANTSBW

V,H

YDRA

NTS

& S

HO

CKS

The 71000 and 71050 Series (non-freeze) and 71020 and 71070 Series (mild climate) Wall Hydrants supply water for any use in all areas of public andprivate buildings. These hydrants are designed to be installed in walls of various types of construction. They incorporate features such as integral vacuumbreaker-backflow preventer, pressure assisted closure and an automatic pressure relief valve. The 71000 and 71020 Series box type hydrants are forinstallation where any protrusion may be a hazard, or where aesthetics or potential vandalism dictate secure flush-with-wall concealment of hydrant.The 71050 and 71070 Series are for installation at the wall surface and are designed so that they will fit into the area occupied by a standard brick.

HYDRASAN® I Features

VACUUM BREAKER-BACKFLOW PREVENTER®

Integral with the hose connection nozzle, respondsinstantly during normal flow to seal off air ports andpermit passage of outflow water. In event of pressureimbalance due to sudden supply pressure drop belowoutlet or back-pressure, response is immediate to sealagainst backflow and open air ports to relieve vacuumand backwater to atmosphere. A must for compliancewith most plumbing codes for protection of thepotable water supply.

LATCHING COVERThis discourages vandalism and provides a flush surfacein areas where any protrusion from the wall would beconsidered a hazard.

SELF-STORING TOOLKey-operated, self storing tool assures that, shouldservice ever become necessary, the working parts of thehydrant can be removed, repaired, and reassembled,quickly and easily, from the front, thus returning thehydrant to operation in a short period of time. No special tools are required.

PRESSURE ASSISTED CLOSUREHydrant is closed utilizing the water pressure in the system. The greater the pressure, the more positive theseal. The force of water pressure moves the shuttle intoits closed position. This design eliminates the surfaceto surface grinding created by conventional types ofhydrant closures, thus prolonging the life of the working parts. Once sealed, the valve will hold evenunder upstream pressure drops to zero p.s.i.

Covered by U.S. and Foreign Patents.

PRESSURE RELIEFAutomatic pressure relief valve relieves water pressurein the attached hose and permits air circulation anddrainage of hydrant and hose. Drainage will take placeproviding discharge end of hose is open. This helpsprevent bursting of hoses in the event of freezing.All servicing is accomplished through face of hydrant.Removal and replacement of seat and shuttle areaccomplished by the hydrant’s self-storing tool, whichis the actuator rod itself. No special tools are requiredwhen hydrant is serviced.

INSTALLATIONHYDRASAN® I Hydrant must be installedwith head horizontal, outlet to right, (asshown). Complete installation, operationand maintenance instructions accompanyeach JOSAM HYDRASAN® Hydrant.

CONCEALED TYPES71000 SERIES NON-FREEZE

71020 SERIES MILD CLIMATE

EXPOSED TYPES71050 SERIES NON-FREEZE

71070 SERIES MILD CLIMATE

NIKALOY BOX AND SATIN SCORIATED COVERSatin face, flush-mounted cover.

Hydrants_08.qxd 3/27/08 12:13 PM Page 240

241

HYDRANTSHYDRANTSBW

V,HYD

RAN

TS & SH

OCKS

How To Order Wall HydrantsEXAMPLE: Series No. 71000 Type No. 71000-6

71000 -6 -74 Series No.

Wall Thickness in Inches

Option, Union Elbow Assembly

Unless optional materials are specified, standard materialshown in specification will be provided. Specify wall thickness.

How To Order Yard HydrantsEXAMPLE: Series No. 71600 Type No. 71600-91-4

71600 -91 -4 -97Series No.

-91 1” Hose Pipe Threaded Outlet

Depth Bury in Feet

Option, 1/8” Tapped Drain Hole in Box

Unless optional materials are specified, standard materialshown in specification will be provided. Specify depth of bury.

HYDRANTS • Pictorial Selection GuideHYDRANTS • Pictorial Selection GuideWALL HYDRANTS • Non-Freeze WALL HYDRANTS • Mild Climate71000with Vacuum Breaker & Box

Page 245

71050with Vacuum Breaker

Page 246

71020with Vacuum Breaker & Box

Page 245

71070with Vacuum Breaker

Page 246

YARD HYDRANTS • Non-Freeze TRI-TEMP71400Standard Duty

Page 247

71450Heavy-Duty

Page 247

71600Heavy-Duty

Page 247

71650Non-Freeze

Page 248

Hydrants_08.qxd 3/27/08 12:13 PM Page 241

242

HYDRANTSHYDRANTSBW

V,H

YDRA

NTS

& S

HO

CKS

We recommend that a complete HYDRANT REPAIR KIT be installed when it becomes necessary to repair a hydrant.

Repair Kits

71550P02U KIT #2

#1 5/16" Key 12

71050P06U KIT #6

#4 Shuttle 2

#5/15 Seal/Seat 2

71050P07U KIT #7

#1 1/4" Key with Set Screw 12

Allen Wrench 12

71050P08U KIT #8

For HYDRASAN® I or II – Non-Freeze

#1 1/4" Key with Set Screw 1

#2 Actuator 1

#4 Shuttle 1

#5 Pressure Assist Rubber Seal 1

#6 Pressure Relief Valve (O-Ring) 1

#15 Seat 1

Allen Wrench 1

71070P09U KIT #9

#4 Shuttle 2

#5/15 Seal/Seat 2

71070P10U KIT #10

For HYDRASAN® I or II – Mild Climate

#1 1/4" Key with Set Screw 1

#2 Actuator 1

#4 Shuttle 1

#5 Pressure Assist Rubber Seal 1

#6 Pressure Relief Valve (O-Ring) 1

#15 Seat 1

Allen Wrench 1

PARTNO. ITEM QTY.

71950P12U KIT #12

For 1420N - 71950

#1 5/16" Key 1

#2 Worm Stem 1

#3 Brass Washer 1

#5 Packing 1

#12 Nylon Seat 1

#15 Plunger 1

71600P14U KIT #14

For 1430N Old Style 3/4" or 1"1440N or 71700 3/4"

71600 3/4" O.S.

#1 5/16" Key 1

#2 Worm Stem 1

#3 Brass Washer 1

#5 Packing 1

#15 Plunger 1

71600P15U KIT #15

For 71600 3/4" or 1"New Style

#1 5/16" Key 1

#2 Worm Stem 1

#3 Brass Washer 1

#15 Plunger 1

#37 Nylon Seal 1

#38 Worm Stem Seal 1

PARTNO. ITEM QTY.

71550P21U KIT #21

For 1400N – 1410N Old Style71550 – 71650 – Previous Design

#1 5/16" Key 1

#2 Worm Stem 1

#3 Brass Washer 1

#4 Packing Nut 1

#5 Packing 1

#12 Nylon Seat 1

#15 Plunger 1

71550P22U KIT #22

For 71500 – 71550 – 71650New Style

#1 5/16" Key 1

#2 Worm Stem 1

#3 Brass Washer 1

#6 Worm Assy. Nut 1

#12 Nylon Seat 1

#15 Plunger 1

#37 Retainer Seal 1

#38 Worm Stem Seal 1

71050P23U KIT #23

For HYDRASAN® I

#28 Vent Ring 2

#29 Boot for Vacuum Breaker 2

#30 Primary Piston 2

#31 Secondary Piston 2

º#32 Snap Ring 2

PARTNO. ITEM QTY.

Hydrants_08.qxd 3/27/08 12:13 PM Page 242

243

HYDRANTSHYDRANTSBW

V,HYD

RAN

TS & SH

OCKS

Parts Drawings

HYDRASAN® I 71000 & 71050 Series

HYDRASAN® I 71020 & 71070 Series

Hydrant replacement parts are available in Repair Kits only. See facing page to determine appropriate kit number.For replacement rod assemblies, contact your local representative.

Hydrants_08.qxd 3/27/08 12:13 PM Page 243

244

HYDRANTSHYDRANTSBW

V,H

YDRA

NTS

& S

HO

CKS

Typical Installations

71000 Series HYDRASAN® I installed in an exterior brick wall

Drawing showing how to determine wall thickness

71600 Series Hydrant shown installed in a yard

71070 Series HYDRASAN® I installed in an exterior brick wall

Drawing showing how to determine depth of bury

71650 Series TRI-TEMP Hydrant shown installed in a block wall

Hydrants_08.qxd 3/27/08 12:13 PM Page 244

HYDRANTSHYDRANTS

245

BWV,H

YDRA

NTS &

SHO

CKS

r WHEN UNION ELBOW IS USED, THIS DIM. IS 6-3/8" OVERALL.* BOX DEPTH IS 1-5/8" ON NIKALOY AND BRONZE BOXES.

r WHEN UNION ELBOW IS USED, THIS DIM. IS 7-5/8" OVERALL.* BOX DEPTH IS 1-5/8" ON NIKALOY AND BRONZE BOXES.

APPLICATIONFor use where a potable water supply is required outside a building. The shut offdesign provides for frost protection and the integral vacuum breaker and backflowpreventer protect the potable water supply. The recessed box with hinged latchingcover conceals the nozzle and operating mechanism and prevents unauthorized use.

SPECIFICATIONJOSAM 71000 Series cast bronze box type non-freeze wall Hydrant with satin stain-less steel hinged latching cover, 3/4" H.P.T. outlet, integral vacuum breaker-backflowpreventer, pressure relief valve, bronze casing, bronze operating parts convertible intoservice tool, 3/4" female and 1" male N.P.T. inlet connection.

APPLICATIONFor use where a potable water supply is required outside a building. The integral vac-uum breaker and backflow preventer protect the potable water supply. The recessedbox with hinged latching cover conceals the nozzle and operating mechanism andprevents unauthorized use.

SPECIFICATIONJOSAM 71020 Series cast bronze box type mild-climate wall Hydrant with satin stain-less steel hinged latching cover, 3/4" H.P.T. outlet, integral vacuum breaker-backflowpreventer, pressure relief valve, bronze operating parts convertible into service tool,3/4" female and 1" male N.P.T. inlet connection.

71000 SERIES HYDRASAN® I WITH VACUUM BREAKER • NON-FREEZE

71020 SERIES HYDRASAN® I WITH VACUUM BREAKER • MILD CLIMATE

Available Options

Available Options

* -52 Satin Finish Face, Cast Bronze Box* -54 Satin Finish Face, Cast Nikaloy Box

-72 Wall Clamp-73 Solder Inlet Adapter-74 Union Elbow Assembly-91 1" Hose Pipe Threaded Outlet-95 Cylinder Vandal-Proof Lock

* -52 Satin Finish Face, Cast Bronze Box* -54 Satin Finish Face, Cast Nikaloy Box

-72 Wall Clamp-73 Solder Inlet Adapter-74 Union Elbow Assembly-91 1" Hose Pipe Threaded Outlet-95 Cylinder Vandal-Proof Lock

TYPE NO. A LBS. TYPE NO. A LBS.71000-4 4-3/4 8 71000-16 16-3/4 1171000-6 6-3/4 9 71000-18 18-3/4 1171000-8 8-3/4 10 71000-20 20-3/4 1271000-10 10-3/4 10 71000-22 22-3/4 1271000-12 12-3/4 10 71000-24 24-3/4 1371000-14 14-3/4 11

TYPE NO. LBS.71020 8

Hydrants_08.qxd 3/27/08 12:13 PM Page 245

HYDRANTSHYDRANTS

246

BWV,

HYD

RAN

TS &

SH

OCK

S

APPLICATIONFor use where a potable water supply is required inside or outside a building. Theshut off design provides for frost protection and the integral vacuum breaker andbackflow preventer protect the potable water supply. Will fit into the area occupiedby a standard brick.

SPECIFICATIONJOSAM 71050 Series cast bronze non-freeze wall Hydrant with satin finish Nikaloyface, 3/4"H.P.T. outlet, integral vacuum breaker-backflow preventer, pressure reliefvalve, bronze casing, bronze operating parts convertible into service tool, 3/4" femaleand 1" male N.P.T. inlet connection.

APPLICATIONFor use where a potable water supply is required inside or outside a building. Theintegral vacuum breaker and backflow preventer protect the potable water supply.Will fit into the area occupied by a standard brick.

SPECIFICATIONJOSAM 71070 Series cast bronze mild-climate wall Hydrant with satin finish Nikaloyface, 3/4" H.P.T. outlet, integral vacuum breaker-backflow preventer, pressure reliefvalve, bronze operating parts convertible into service tool, 3/4" female and 1" maleN.P.T. inlet connection.

-50 Satin Finish Bronze Face-72 Wall Clamp-73 Solder Inlet Adapter-74 Union Elbow Assembly-91 1" Hose Pipe Threaded Outlet

Available Options

-50 Satin Finish Bronze Face-72 Wall Clamp-73 Solder Inlet Adapter-74 Union Elbow Assembly-91 1" Hose Pipe Threaded Outlet

Available Options

71050 SERIES HYDRASAN® I WITH VACUUM BREAKER • NON-FREEZE

71070 SERIES HYDRASAN® I WITH VACUUM BREAKER • MILD CLIMATE

r WHEN UNION ELBOW IS USED, THIS DIM. IS 6-3/8" OVERALL.

r WHEN UNION ELBOW IS USED, THIS DIM. IS 5-3/4" OVERALL.

TYPE NO. A LBS. TYPE NO. A LBS.71050-3 2-3/4 3 71050-14 14 571050-4 4 3 71050-16 16 571050-6 6 3 71050-18 18 571050-8 8 4 71050-20 20 671050-10 10 4 71050-22 22 671050-12 12 4 71050-24 24 6

TYPE NO. LBS.71070 4

Hydrants_08.qxd 3/27/08 12:13 PM Page 246

HYDRANTSHYDRANTS

247

BWV,H

YDRA

NTS

&SH

OCKS

APPLICATIONFor use where an outside potable water supply is required. N.P.T. hole drains thebody for frost protection.

SPECIFICATIONJOSAM 71400 Series galvanized steel non-freeze ground Hydrant with cast iron head,solid brass 3/4” H.P.T. outlet, cam type operating control lever for full or variable flow,stainless steel operating rod, one-piece plunger and 3/4” F.P.T. inlet.

APPLICATIONFor use in industrial environments where an outside potable water supply is required.N.P.T. hole drains the body for frost protection.

SPECIFICATIONJOSAM 71450 Series galvanized steel non-freeze ground Hydrant with heavy-duty castiron head, solid brass H.P.T. outlet, cam type operating control lever for full or variableflow, stainless steel operating rod, one-piece plunger and 3/4” F.P.T. inlet.

-91 1” Hose Pipe Threaded Inlet and Outlet

71400 SERIES GROUND HYDRANT • NON-FREEZE

71450 SERIES GROUND HYDRANT, HEAVY-DUTY • NON-FREEZE

Available Option

TYPE NO. SIZE OVERALL LENGTH LBS.71400-1 1’ Bury 45” 1171400-2 2’ Bury 57” 1371400-3 3’ Bury 69” 1571400-4 4’ Bury 81” 1771400-5 5’ Bury 93” 1971400-6 6’ Bury 105” 21

TYPE NO. SIZE OVERALL LENGTH LBS.71450-1 1’ Bury 46” 1371450-2 2’ Bury 58” 1571450-3 3’ Bury 70” 1771450-4 4’ Bury 82” 1971450-5 5’ Bury 94” 2171450-6 6’ Bury 106” 23

Hydrants_08.qxd 5/2/08 2:23 PM Page 247

HYDRANTSHYDRANTS

248

BWV,

HYD

RAN

TS&

SHO

CKS

APPLICATIONFor use where an outside potable water supply is required. The 1/8" NPT hole drainsthe body for frost protection and the recessed box with hinged latching cover con-ceals the nozzle and operating mechanism and prevents unauthorized use.

SPECIFICATIONJOSAM 71600 Series cast bronze non-freeze yard Hydrant with 3/4” H.P.T. outlet,satin finish face Nikaloy box, hinged latching cover, bronze casing, Neoprene plunger,removable bronze operating parts and straight inlet with standard hose connection.

APPLICATIONFor use where a potable supply of cold, hot or mixed water is required such as dairies orwash down sites. The shut off design provides for frost protection and the recessed boxwith hinged latching cover conceals the nozzle and operating mechanism and preventsunauthorized use.

SPECIFICATIONJOSAM 71650 Series TRI-TEMP cast bronze non-freeze wall Hydrant with T-Handle, satinfinish face Nikaloy box, hinged latching cover, bronze casings, Neoprene plungers, remov-able nylon seats, removable bronze operating parts, 3/4" female and 1" male N.P.T. inletconnections for hot and cold water and a mixing chamber with 3/4" H.P.T. outlet.

-52 Satin Finish Face, Bronze Box-91 1” Hose Pipe Threaded Outlet-95 Cylinder Vandal-Proof Lock-97 1/8" Tapped Drain Hole in Box

-72 Wall Clamps-73 Solder Inlet Adapters-74 Union Elbow Assemblies-81 Vacuum Breaker-91 1" Hose Pipe Threaded Outlet-95 Cylinder Vandal-Proof Lock

71600 SERIES YARD HYDRANT, BOX TYPE • NON-FREEZE

71650 SERIES TRI-TEMP WALL HYDRANT, BOX TYPE • NON-FREEZE

Available Options

Available Options

TYPE NO. SIZE LBS.71600-2 2’ Bury 671600-3 3’ Bury 871600-4 4’ Bury 1171600-5 5’ Bury 1371600-6 6’ Bury 15

TYPE NO. A LBS. TYPE NO. A LBS.71650-6 6 24 71650-16 16 2971650-8 8 25 71650-18 18 3071650-10 10 26 71650-20 20 3171650-12 12 27 71650-22 22 3271650-14 14 28 71650-24 24 33

r WHEN UNION ELBOW IS USED, THIS DIM. IS 5-3/8" OVERALL.

Hydrants_08.qxd 5/2/08 1:22 PM Page 248

249

SHOCK ABSORBERSSHOCK ABSORBERSBW

V,HYD

RAN

TS & SH

OCKS

The proper size of ABSORBOTRON® units can be determined for one or more fixtures on the basis of the Fixture-Unit values as shown in the tables below.

ABSORBOTRON® Sizes & Fixture-Unit Ratings

The JOSAM Fixture-Unit Sizing Method established in accordance with Plumbing and Drainage Institute"Standard P.D.I.-WH201" provides a simple and accuratemethod of determining the size of ABSORBOTRON®

required for each plumbing fixture supply branch, andautomatically takes into consideration all of the factorswhich must be considered or otherwise calculated.

To determine the size of ABSORBOTRON® required bythis easy method, simply refer to the Fixture-Unit Rating of each fixture on the cold or hot water lines.Add the total number of cold or hot water fixture-unitson each line and use this total to select the properABSORBOTRON®, as shown in the Selector Chart.

This method provides less chance of error since all facts required for selection are known. It is the method preferred by engineers.

SELECTOR CHART TABLE IV

CAPACITY IN FIXTURE-UNITSType of Supply Public Private

Fixture Control C. W. H. W. C. W. H. W.Water Closet Flush Valve 10 - 6 -

Water Closet Flush Tank 5 - 3 -

Pedestal Urinal Flush Valve 10 - - -

Stall or Wall Urinal Flush Valve 5 - - -

Stall or Wall Urinal Flush Tank 3 - - -

Lavatory Faucet 1-1/2 1-1/2 1 1

Bathtub Faucet 2 3 1-1/2 1-1/2

Shower Head Mixing Valve 2 3 1 2

Bathroom Group Flush Valve Closet - - 8 3

Bathroom Group Flush Tank Closet - - 6 3

Separate Shower Mixing Valve - - 1 2

Service Sink Faucet 3 3 - -

Laundry Tubs (1-3) Faucet - - 3 3

Combination Fixture Faucet - - 3 3

† Meet P.D.I. Standard WH-201 and A.S.S.E. Standard 1010. Certificate of Compliance available on request.

SPECIAL APPLICATIONSThe JOSAM Engineering Department will assist you with respect to any special water hammer problems. When submitting your request, please include the following information, if possible.

1. Type of equipment or fixtures to be served

2. Schematic sketch of piping system

3. Size of pipe used

4. Water pressure

5. Velocity of water flow through piping (if known)

COLD WATER BRANCH = 26 F. U. = JOSAM Type No. 75002B ABSORBOTRON®

HOT WATER BRANCH = 6 F. U. = JOSAM Type No. 75001A ABSORBOTRON®

s Pressure Reducing Valves should be installed on branch lines serving fixtures and equipment, when the pressure in the line exceeds 60 p.s.i. Most fixtures and equipment are designed to function at pressures ranging between 20 p.s.i. and 50 p.s.i. For quiet flow of water in the piping, it is recommended that a velocity between 5-8 feet per second be maintained.

COLD WATER BRANCH = 36 F. U. = JOSAM Type No. 75003C ABSORBOTRON®

HOT WATER BRANCH = 6 F. U. = JOSAM Type No. 75001A ABSORBOTRON®

EXAMPLEFor purpose of example, the following applications are offered.Branch line control valves are not shown. s

EXAMPLE 1

EXAMPLE 2

FIXTURE-UNIT RATING TABLE

ABSORBOTRON® TYPE NO. 75000-S= 75001A= 75001-S

= 75002B= 75002-S

= 75003C= 75003-S

= 75004D= 75004-S

= 75005E= 75005-S

= 75006F= 75006-S

P.D.I. SYMBOLS † AA A B C D E F

Fixture-Unit Rating 1 1-11 12-32 33-60 61-113 114-154 155-330

Shock Absorbers_08.qxd 3/27/08 12:19 PM Page 249

250

SHOCK ABSORBERSSHOCK ABSORBERSBW

V,H

YDRA

NTS

& S

HO

CKS

The majority of sizing and selection applications will involve single and multiple fixture branch lines. These are easily handled with Table IV.The remainder of applications involves individual runs of piping to a remote item of equipment. The properly sized water hammer arresters for such applications can be determined by Table V and Table V-A.

P.D.I. Water Hammer Arrester Sizes

25 A A B C D E50 A B C D E F75 B C D AE F EF

100 C D E F CF FF125 C D F AF EF EFF150 D E F DF FF FFF

Length of Nominal Pipe DiameterPipe 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

Ideally the flow pressure in branch lines serving fixtures should never exceed 60 P.S.I.G. Pressure reducing valves should beinstalled to maintain proper pressure. However, when flow pressures of 65 to 85 P.S.I.G. are used, the next larger size waterhammer arrester should be selected. Refer to Table V-A.

All sizing data in this section are based on flow velocities of 10 F.P.S. or less. The certification testing was conducted with avelocity of 10 F.P.S. to offer assurance that P.D.I. approved unitswere capable of handling shocks of maximum intensity thatmay be encountered.

When long runs of piping are employed to serve a remote item of equipment, the water hammer arrester should be located as close as possible to the point of quick closure.At this location, the water hammer arrester will control the developed energy and prevent the shock wave from surgingthrough the piping system.

NOTE: For best performance results, the ABSORBOTRON® IIshould always be installed in an upright position and located as close as possible to the fixture or equipment closure valve.

The Riser Diagram illustrated below, shows a typical placement of Shock Absorbers on the branch lines in the pipe space behind the fixtures.The branch line control valves are not shown in this instance.

PRIVATE SELECTION PUBLIC SELECTION

It is relatively easy to select the proper sized Shock Absorber for amultiple fixture branch. The above represents a typical riser diagramthat an engineer may include with his set of drawings

When sizing the cold and hot water branch lines, it is usual practice to obtain the total number of fixture units on each branch line. This information is then applied to water pipe sizing charts to determinethe required size of the branch lines.

The proper size of Shock Absorber can also be selected once the totalof fixture-units for a cold or hot water branch line is known. It is onlynecessary to apply the fixture-units to The Selector Chart, Table IV andselect the appropriate Shock Absorber.

It is suggested that the engineer employ P.D.I. symbols for his riser diagrams, as shown in the illustration above. This practice will enablemanufacturers to furnish the correct units.

TABLE VFOR WATER PRESSURES UP TO 65 P.S.I.G.

EXAMPLE

P.D.I. Water Hammer Arrester Sizes

25 B B C D E F50 B C D E F CF75 C D E F CF FF100 D E F CF EF EFF125 D E CF DF FF BFFF150 E F CF FF DFF FFFF

Length of Nominal Pipe DiameterPipe 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"

TABLE V-AFOR WATER PRESSURES OVER 65 P.S.I.G. AND UP TO 85 P.S.I.G.

Typical Application in Multi-Story Buildings

Selection for Long Piping Runs

Shock Absorbers_08.qxd 3/27/08 12:19 PM Page 250

SHOCK ABSORBERSSHOCK ABSORBERS

251

BWV,H

YDRA

NTS

&SH

OCKS

APPLICATIONFor use where hydrostatic shock may be present such as near flush valves, faucets,laundry machines, dishwashers or any type of pneumatic, electric or spring-loadedquick closing valve.

SPECIFICATIONJOSAM 75000 Series ABSORBOTRON II® Shock Absorber with stainless steel shell,hydro-pneumatic cushion of nitrogen, stainless steel bellows and stainless steel malethreaded pipe nipple.

APPLICATIONFor use where hydrostatic shock may be present such as near flush valves, faucets,laundry machines, dishwashers or any type of pneumatic, electric or spring-loadedquick closing valve.

SPECIFICATIONJOSAM 75000-S Series ABSORBOTRON II® Shock Absorber with wrought copper shell,hydro-pneumatic air cushion, HHPP piston, wrought copper adapter and male threadedconnection.

75000 SERIES STAINLESS STEEL

75000-S SERIES COPPER

Type numbers 75001A through 75006F meet P.D.I. Standard WH-201 and A.S.S.E.Standard 1010.

Certificate of Compliance available on request.

Type numbers 75001-S through 75006-S meet A.S.S.E. Standard WH-2010.

Certificate of Compliance available on request.

TYPE NO.

P.D.I.SIZE

FIXTUREUNITS

PIPESIZE H LBS.

75001A A 1-11 3/4 3-1/8 1.075002B B 12-32 1 4 1.375003C C 33-60 1 4-5/8 3.075004D D 61-113 1 5-1/2 4.075005E E 114-154 1 7-1/16 4.575006F F 155-330 1 7-1/16 5.0

TYPE NO.

P.D.I.SIZE

FIXTUREUNITS A B C LBS.

75000-S AA 1 1/2 4-1/2 7/8 175001-S A 1-11 1/2 6-1/2 1-3/8 175002-S B 12-32 3/4 8-3/4 1-3/8 175003-S C 33-60 1 11 1-3/8 175004-S D 61-113 1 10-1/8 2-1/8 275005-S E 114-154 1 12-5/8 2-1/8 375006-S F 155-330 1 15-1/8 2-1/8 4

Shock Absorbers_08.qxd 5/2/08 1:27 PM Page 251

Shock Absorbers_08.qxd 3/27/08 12:19 PM Page 252

76004 -X -1 - 30

Outlet Size

Outlet Type, Inside Caulk Outlet

Optional Material, Satin Finish Nikaloy Top

Option, Flashing Clamp Device

253

TRENCH DRAINSTRENCH DRAINSTREN

CH D

RAIN

S

EXAMPLE: Series No. 76000 Type No. 76004

76000 & 76010 Series Ordering Information

EXAMPLE: For center outlet and two extensions, specify X-O-X.

1.Specify type number and options as above.

2.Specify total quantity of outlets and total quantity of extensions.

3.Assembly is recommended when nikaloy and bronze tops are ordered.

When assembly is required, indicate layout of outlets and extensions,

using "O" for outlet and "X" for extensions.

Unless optional materials are specified, standard material shown in Specification will be provided.Last digit indicates outlet size.

Trench Grate Ordering Information76300, 76500 and 76700 Series Grates are used in an END-TO-END configuration.

76400, 76600 and 76800 Series Frame & Grate Assemblies use 76300, 76500 and

76700 Series Grates respectively in a SIDE-BY-SIDE configuration.

Options

How To Order

(-11) OPTION, HEAVY-DUTY CONVEX GRATEallows drainage through openings in top of grate even in the eventof perimeter blockages by leaves or debris.

(-30) OPTION, FLASHING CLAMP DEVICEassures the positive bond of the membrane between the flangeand clamp ring.

Trench Drains_08.qxd 3/27/08 3:12 PM Page 253

TRENCH DRAINS • Pictorial Selection GuideTRENCH DRAINS • Pictorial Selection Guide

254

TREN

CHD

RAIN

S

APPLICATIONFor use in heavy traffic areas where a continuous trench drain is required such as inparking garages, vehicle repair facilities, manufacturing plants and ramps. The inter-nal dome strainer intercepts debris, that could block the drain line. An outlet sectioncan be used individually as an area drain.

SPECIFICATIONJOSAM 76000 Series coated cast iron rectangular sectional Trench Drain with heavy-duty body sections and integral anchor flange, heavy-duty loose-set SUPER-FLO® Grateswith perimeter drainage slots, 5/16" x 3-1/2" grate openings, secondary loose-set domestrainer and bottom outlet inside caulk connection.

76000 SERIES SUPER-FLO® 6" WIDE, RECTANGULAR

-EXT Extension Section-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-7 Ductile Iron Grate

* -VP Secured Grate,Vandal-Proof Screws

-30 Flashing Clamp Device-40 Galvanized Cast Iron Parts

OUTLET:-X Inside Caulk Outlet

Available Options

TYPE NO. PIPE SIZE

LENGTH IN. LBS.

OUTLETSECTION

EXTENSIONSECTION

OUTLETSECTION

EXTENSIONSECTION

76002 2 9 15 32 3276003 3 9 15 32 3276004 4 9 15 32 32 FOR OUTLET TYPE SPECIFY -X

GRATE SLOT OPENINGS ARE: 3-1/2" x 5/16" C. I. 1-11/16" x 1/4" BRONZE AND NIKALOY

IT IS RECOMMENDED THAT NO MORE THAN 8 EXTENSION SECTIONS BE USED WITH ONE OUTLET SECTION.

ADD 1/4" FOR NIKALOY OR BRONZE TOP.

© ADD 1/4" TO WIDTH AND OVERALL LENGTH FOR NIKALOY OR BRONZE TOP.

*For installations exposed to vehicular traffic, specify -VP, Secured Grate.

6" WIDE TRENCH DRAIN 12" WIDE TRENCH DRAIN760005" Deep, Heavy-Duty SUPER-FLO® Grate

Page 254

760107-5/8" Deep, Heavy-Duty Grate

Page 255

FRAMES & GRATES76300, 7640012-3/8" Wide, Light-Duty Grate

Page 255

76500, 7660012-5/8" Wide, Medium-Duty Grate

Page 256

76700, 7680012-5/8" Wide, Heavy-Duty Grate

Page 256

Trench Drains_08.qxd 5/2/08 1:34 PM Page 254

TRENCH DRAINSTRENCH DRAINS

255

TRENCH

DRA

INS

APPLICATIONFor use in heavy traffic areas where a wide, continuous trench drain that can serve asa temporary reservoir for large quantities of water is required, such as in parkinggarages, vehicle repair facilities, manufacturing plants and ramps. An outlet sectioncan be used individually as an area drain.

SPECIFICATIONJOSAM 76010 Series coated cast iron rectangular sectional Trench Drain with heavy-dutybody sections and integral anchor flange, heavy-duty loose-set grates, 7/16" x 2-3/4"grate openings and bottom outlet.

76010 SERIES 12" WIDE, RECTANGULAR

-EXT Extension Section-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-7 Ductile Iron Grate-11 Convex Grate-VP Secured Grate,

Vandal-Proof Screws

-30 Flashing Clamp Device-40 Galvanized Cast Iron Parts-70 Sediment Bucket-70-40 Bucket, Galvanized

OUTLET:-X Inside Caulk Outlet

GRATE SLOT OPENING 2-3/4” X 7/16”

IT IS RECOMMENDED THAT NO MORE THAN 8 EXTENSION SECTIONS BE USED WITH ONE OUTLET SECTION.

ADD 1/4" WHEN FURNISHED WITH NIKALOY OR BRONZE TOP.

© ADD 3/8" TO WIDTH AND OVERALL LENGTH FOR NIKALOY OR BRONZE TOP.

GRATE SLOT OPENING 5” X 1/2” C.I.3-1/4” X 5/16” NIKALOY & BRONZE

DIM. OF TRENCH IS "C" DIM. LESS 1-1/2".

FREE AREA OF EACH GRATE IS 110 SQ. IN.

DIM. GIVEN IS BACK-TO-BACK OF 3/4" x 3/4" x 1/8" ANGLE FRAME.

n LAST TWO DIGITS OF THESE SERIES INDICATE THE NUMBER OF GRATES.

APPLICATIONFor use in pedestrian and light wheel traffic areas where a concrete or similarly con-structed trench with 5/8" recessed frame, by others, has been constructed for use withJOSAM grate only. May be used end-to-end for 12" wide trench as long as needed.76301 includes single grate and frame, by JOSAM, 20-3/8" x 12-3/8". 76302 includesend-to-end grates and frame by JOSAM. Frame and grate combination may beordered to the necessary length to complete a continuous trench 12-3/8" wide. 76402includes side-by-side grates and frame, by JOSAM. Frame and grate combination maybe ordered to the necessary length to complete a continuous trench 20-3/8” wide.

SPECIFICATIONJOSAM 76300 and 76400 Series coated cast iron rectangular light-duty sectionalTrench Grate, 12" x 20" with 1/2" x 5" grate openings.

76300 & 76400 SERIES LIGHT-DUTY, RECTANGULAR

Available Options-1 Satin Finish Nikaloy Grate,

Stainless Steel Frame-7 Ductile Iron Grate-8-2 All Bronze with

Satin Finish Top

-VP Secured Grate,Vandal-Proof Screws

-40 Galvanized

Available Options

SERIES NO. TYPE NO. DESCRIPTION C LBS.76300 76300 Grate Only 20 2976300 76301 Single Grate & Frame 20-3/8 3476300 76302 2-Grate Section 40-3/8 6476400 76402 2-Grate Section 24-3/8 59

TYPE 76301 GRATE AND FRAME

Trench Drains_08.qxd 5/2/08 1:34 PM Page 255

TRENCH DRAINSTRENCH DRAINS

256

TREN

CHD

RAIN

S

APPLICATIONFor use in medium traffic areas where a concrete or similarly constructed trench with 1-1/4" recessed frame, by others, has been constructed for use with JOSAM grate only. May be used end-to-end for 12" wide trench as long as needed. 76501 includessingle grate and frame, by JOSAM, 24-5/8" x 12-5/8". 76502 includes end-to-endgrates and frame, by JOSAM. Frame and grate combination may be ordered to thenecessary length to complete a continuous trench 12-5/8" wide. 76602 includes side-by-side grates and frame by JOSAM. Frame and grate combination may be ordered tothe necessary length to complete a continuous trench 24-5/8" wide.

SPECIFICATIONJOSAM 76500 and 76600 Series coated cast iron rectangular medium-duty sectionalTrench Grate, 12" x 24" with 1/2" x 4-3/8" grate openings.

-1 Satin Finish Nikaloy Grate, Stainless Steel Frame-7 Ductile Iron Grate-8-2 All Bronze with Satin Finish Top-VP Secured Grate, Vandal-Proof Screws-40 Galvanized

APPLICATIONFor use in heavy traffic areas where a concrete or similarly constructed trench with 1-1/4" recessed frame, by others, has been constructed for use with JOSAM grateonly. May be used end-to-end for 12" wide trench as long as needed. 76701includes single grate and frame by JOSAM, 24-5/8" x 12-5/8". 76702 includes end-to-end grates and frame by JOSAM. Frame and grate combination may be ordered tothe necessary length to complete a continuous trench 12-5/8" wide. 76802 includesside-by-side grates and frame by JOSAM. Frame and grate combination may beordered to the necessary length to complete a continuous trench 24-5/8" wide.

SPECIFICATIONJOSAM 76700 and 76800 Series coated cast iron rectangular heavy-duty sectionalTrench Grate, 12" x 24" with 1-1/2" x 4-1/4" grate openings.

76700 & 76800 SERIES HEAVY-DUTY, RECTANGULAR

-1 Satin Finish Nikaloy Grate, Stainless Steel Frame-7 Ductile Iron Grate-8-2 All Bronze with Satin Finish Top-VP Secured Grate, Vandal-Proof Screws-40 Galvanized

76500 & 76600 SERIES MEDIUM-DUTY, RECTANGULAR

Available Options

Available Options

SERIES NO. TYPE NO. DESCRIPTION C LBS.76500 76500 Grate Only 24 4076500 76501 Single Grate & Frame 24-5/8 5776500 76502 2-Grate Section 48-5/8 10876600 76602 2-Grate Section 24-5/8 103

SERIES NO. TYPE NO. DESCRIPTION C LBS.76700 76700 Grate Only 24 5676700 76701 Single Grate & Frame 24-5/8 7376700 76702 2-Grate Section 48-5/8 14076800 76802 2-Grate Section 24-5/8 135

GRATE SLOT OPENING 4-3/8” X 1/2”DIM. OF TRENCH IS "C" DIM. LESS 3"FREE AREA OF EACH GRATE IS 90 SQ. IN.DIM. GIVEN IS BACK-TO-BACK OF 1-1/2" x 1-1/2" x 1/4" ANGLE FRAME.

n LAST TWO DIGITS OF THESE SERIES INDICATE THE NUMBER OF GRATES.

GRATE SLOT OPENING 4-1/4” X 1-1/2”DIM. OF TRENCH IS "C" DIM. LESS 3"FREE AREA OF EACH GRATE IS 100 SQ. IN.DIM. GIVEN IS BACK-TO-BACK OF 1-1/2" x 1-1/2" x 1/4" ANGLE FRAME.

n LAST TWO DIGITS OF THESE SERIES INDICATE THE NUMBER OF GRATES.

Trench Drains_08.qxd 5/2/08 1:34 PM Page 256

257

MISCELLANEOUS PRODUCTS85220Pit Drain, Threaded Side Outlet

Page 258

8580012-3/4" x 7-1/2" Top, Threaded Outlet

Page 258

8581012-7/8" x 5-3/8" Top, Inside Caulk Outlet

Page 259

85903-ZLight Traffic Drain, No-Hub Outlet

Page 259

P-TRAPS TRAP SEAL PRIMERS88100Spigot Connections

Page 260

88210Funnel Inlet, Side OutletThreaded Connection

Page 260

88250Primer Valve, Vacuum Breaker,Gasketed Cover

Page 261

88300Trap Primer & Distribution Unit

Page 261

ADAPTERS88400No-Hub Spigot Adapter

Page 262

88450Trap Primer Adapter

Page 262

88550Hub Adapter, Female Threaded Outlet

Page 263

88560 88600Hub Adapter Reducing Hub

Male Threaded Outlet

Pages 263, 264

AIR GAPS FRESH AIR INLETS88900Threaded Inlet, XH Spigot Outlet

Page 264

88910Female Threaded Inlet & Outlet

Page 265

88950Perforated Grille

Page 265

88970Convex Grille

Page 266

MISC., TRAPS & ACCESS. • Pictorial Selection GuideMISC., TRAPS & ACCESS. • Pictorial Selection GuideM

ISC.,TRAPS

&ACCESS.

Misc - Traps & Access_08.qxd 3/27/08 3:04 PM Page 257

MISCELLANEOUS PRODUCTSMISCELLANEOUS PRODUCTS

258

MIS

C.,T

RAPS

&AC

CESS

.

APPLICATIONThreaded side outlet drain for use at the base of walls in pits or pools, whereelevation is limited. Angle grate provides ample drainage and is slotted to prevententrance of debris.

SPECIFICATIONJOSAM 85220 Series coated cast iron 5" x 7" 90° angle Swimming Pool and PitDrain with anchor flange, secured bar type angle grate with frame and side outletthreaded connection.

APPLICATIONFor use in non-traffic areas where space is limited such as in trenches, under countersor against walls or in locations requiring narrow drains with ample free drainage.

SPECIFICATIONJOSAM 85800 Series coated cast iron 12-3/4" x 7-1/2" drain, loose-set anti-tiltinggrate and bottom outlet threaded connection.

-3 Chrome Plated Bronze Face-VP Secured Face, Vandal-Proof Screws-41 Clamp Device-42 Ground Screw-47 Galvanized Cast Iron Parts

OUTLET:-T Threaded Outlet

-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-3 Chrome Plated Bronze Top-VP Secured Grate, Vandal-Proof Screws-42 Grounding Screw-47 Galvanized Cast Iron Parts

OUTLET:-T Threaded Outlet

85220 SERIES 5" X 7" 90° ANGLE STRAINER

85800 SERIES RECTANGULAR PATTERN

Available Options

Available Options

FOR OUTLET TYPE SPECIFY -TTYPE NO. PIPE SIZE B LBS.

85222 2 1-3/4 1885223 3 1-1/4 1885224 4 3/4 18

FOR OUTLET TYPE SPECIFY -TTYPE NO. PIPE SIZE LBS.

85804 4 2985805 5 2985806 6 29

ADD 1/4" FOR NIKALOY OR BRONZE TOP.

Misc - Traps & Access_08.qxd 3/27/08 3:04 PM Page 258

MISCELLANEOUS PRODUCTSMISCELLANEOUS PRODUCTS

259

APPLICATIONFor use in non-traffic areas where space is limited such as in trenches, under countersor against walls, in locations requiring narrow drains with ample free drainage.

SPECIFICATIONJOSAM 85810 Series coated cast iron 12-7/8" x 5-3/8" Drain, loose-set anti-tiltinggrate and bottom outlet.

APPLICATIONFor use in light traffic areas such as boiler rooms or mechanical rooms where awaterproofing membrane is not utilized.

SPECIFICATIONJOSAM 85903-Z Series coated cast iron drain with no-hub connection and medium-duty secured grate.

85810 SERIES RECTANGULAR PATTERN

85903-Z SERIES CAST IRON DRAIN

-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-3 Chrome Plated Bronze Top-VP Secured Grate, Vandal-Proof Screws-42 Grounding Screw-47 Galvanized Cast Iron Parts

OUTLETS:-T Threaded Outlet-X Inside Caulk Outlet

Available Options

FOR OUTLET TYPE SPECIFY -T or -X,TYPE NO. PIPE SIZE LBS.

85812 2 1885813 3 1885814 4 18

ADD 1/4" FOR NIKALOY OR BRONZE TOP.

GRATE FREE AREA 11 SQ. IN

MISC.,TRA

PS&

ACCESS.TYPE NO. PIPE SIZE LBS.85903-Z 3 4

Misc - Traps & Access_08.qxd 3/27/08 3:04 PM Page 259

TRAPS & ACCESSORIESTRAPS & ACCESSORIES

260

MIS

C.,T

RAPS

&AC

CESS

.

APPLICATIONFor use with any bottom outlet floor drain where a “P” trap with a bottom accesscleanout is required to prevent sewer gas or vermin from entering the building.

SPECIFICATIONJOSAM 88100 Series coated cast iron "P" Trap, spigot inlet and side outlet spigotconnection.

APPLICATIONFor use in hospitals or laboratories to collect indirect waste such as condensation orother drips or spills. This deep seal trap with a bottom access cleanout may be usedto prevent sewer gas or vermin from entering the building.

SPECIFICATIONJOSAM 88210 Series coated cast iron Deep Seal "P" Trap with indirect waste funnelinlet and side outlet threaded connection.

88100 SERIES “P” TRAP

88210 SERIES DEEP SEAL TRAP, FUNNEL INLET

-51 1/2" Flushing Tap-60 Bronze Plug

-8 All Bronze-51 1/2" Flushing Tap-72 Bronze Bucket

Available Options

Available Options

NOTE: WHEN (-51) FLUSHING CONNECTION IS USED, A VACUUM BREAKER SHOULD BE INSTALLED SUBJECT TO CODE REQUIREMENTS.

NOTE: WHEN (-51) FLUSHING CONNECTION IS USED, A VACUUM BREAKER SHOULD BE INSTALLED SUBJECT TO CODE REQUIREMENTS.

TYPE NO. PIPE SIZE D E F H J K LBS.88102 2 9-5/16 1-5/16 8-1/8 3-1/4 6-13/16 1-1/2 2088103 3 11-1/2 1-3/4 9-3/4 3 8 2 3688104 4 15-3/8 2 13-1/4 4-1/8 11-1/4 3 38

TYPE NO. PIPE SIZE B C D E G H LBS.88212 2 4 6-5/8 6 5-3/4 1 2-3/8 1088213 3 5 8-1/2 8-1/4 8 2 3-1/4 20

Misc - Traps & Access_08.qxd 5/1/08 4:30 PM Page 260

TRAPS & ACCESSORIESTRAPS & ACCESSORIES

261

MISC.,TRA

PS&

ACCESS.

APPLICATIONFor use with tapped floor drains in locations where infrequent use or other conditionsmight permit the water seal to evaporate, allowing sewer gas or objectionable andcontaminating odors to escape through the drain. The trap primer valve is connectedto a water supply line and sends a precise amount of water, with each use, to thetrap to compensate for evaporation and ensure maintenance of a water seal in thetrap at all times.

SPECIFICATIONJOSAM 88250 Series all bronze Primer Valve with removable operating parts, integralvacuum breaker and gasketed access cover for installation in a cold water service lineto a plumbing fixture with trap connection for maintaining trap seal.

APPLICATIONFor use with two to four tapped floor drains in locations where infrequent use orother conditions might permit the water seal to evaporate, allowing sewer gas orobjectionable and contaminating odors to escape through the drain. The trap primervalve is connected to a cold water supply line and sends a precise amount of water,with each use, to the trap to compensate for evaporation and ensure maintenance ofa water seal in the trap at all times.

SPECIFICATIONJOSAM 88300 Series all bronze trap primer valve with 1/2” N.P.T. inlet, integral back-flow preventer, vacuum breaker ports and 1/2” F.N.P.T. outlet for connection to plasticdistribution unit for two to four plumbing fixtures.

88250 SERIES TRAP SEAL PRIMER VALVE

88300 SERIES TRAP PRIMER VALVE & DISTRIBUTION UNIT

-10 Polished Chrome Plated-90 1/2" Female Copper Connection-91 1/2" Female IPS Union Connection

TYPE NO. LBS.88250 3

TYPE NO. LBS.88300 1.5

Available Options

Misc - Traps & Access_08.qxd 3/27/08 3:04 PM Page 261

TRAPS & ACCESSORIESTRAPS & ACCESSORIES

262

MIS

C.,T

RAPS

&AC

CESS

.

APPLICATIONFor use when extending no-hub bottom outlet or accepting water from trap primerconnection through optional primer tap.

SPECIFICATIONJOSAM 88400 Series coated cast iron Spigot Adapter with no-hub by no-hub connections.

APPLICATIONFor use when accepting water from trap primer connection through optional low-profileprimer tap adapter when drain body is not tapped.

SPECIFICATIONJOSAM 88450 Series coated cast iron trap primer adapter with no-hub by gasketedhub connections.

88400 SERIES NO-HUB SPIGOT ADAPTER

88450 SERIES TRAP PRIMER ADAPTER

-40 Galvanized Cast Iron Parts-49 3/4" Primer Tap-50 1/2" Primer Tap

TYPE NO. A B C D LBS.88402 2-5/16 1-13/32 2-3/4 2-3/4 388403 3-3/8 1-15/16 2-1/2 3 588404 4-3/8 2-1/2 2-5/16 3 588406 6-5/16 3-1/2 2-1/4 3-1/4 888408 8-7/16 4-1/2 2 3-1/2 14

Available Options

TYPE NO. PIPE SIZE A B LBS.88452 2 3-5/8 5 488453 3 4-3/4 5-1/4 588454 4 5-3/4 5-3/4 6

Misc - Traps & Access_08.qxd 5/1/08 4:30 PM Page 262

TRAPS & ACCESSORIESTRAPS & ACCESSORIES

263

MISC.,TRA

PS&

ACCESS.

APPLICATIONFor use when converting from male threaded connection to bell or hub for caulking.

SPECIFICATIONJOSAM 88550 Series coated cast iron Hub Adapter with standard cast iron soil pipehub and female threaded outlet.

APPLICATIONFor use when converting from female threaded connection to bell or hub for caulking.

SPECIFICATIONJOSAM 88560 Series coated cast iron Hub Adapter with standard cast iron soil pipehub and male threaded outlet.

88550 SERIES HUB ADAPTER, THREADED OUTLET

-40 Galvanized Cast Iron Parts

-40 Galvanized Cast Iron Parts

Available Option

Available Option

88560 SERIES HUB ADAPTER, THREADED OUTLET

TYPE NO. PIPE SIZE B q C D E LBS.88553 3 4-1/4 5-1/4 3 2-1/4 588554 4 5-3/8 6-1/4 2-7/8 2-3/8 588555 5 6-1/4 7-1/4 3-1/2 2-7/8 788556 6 7-1/2 8-1/4 3-5/8 3 8

q MEETS ASTM A-74 XH C.I. SOIL PIPE STANDARD.

TYPE NO. PIPE SIZE B q C D E LBS.88562 2 3 3-7/8 4 2-1/4 488563 3 4-1/4 5-1/8 4-1/4 2-3/8 588564 4 5-1/4 6-1/8 4-3/8 2-3/8 688565 5 6-1/4 7-1/8 4-3/8 2-3/8 788566 6 7-1/4 8 4-3/8 2-3/8 888568 8 9-1/4 10-1/2 4-3/8 2-1/4 11

q MEETS ASTM A-74 XH C.I. SOIL PIPE STANDARD.

Misc - Traps & Access_08.qxd 3/27/08 3:04 PM Page 263

TRAPS & ACCESSORIESTRAPS & ACCESSORIES

264

MIS

C.,T

RAPS

&AC

CESS

.

APPLICATIONFor use when reducing from bell or hub to female threaded connection.

SPECIFICATIONJOSAM 88600 Series coated cast iron Hub Adapter with standard cast iron soil pipehub and male threaded outlet.

APPLICATIONFor use between waste outlets and the plumbing drainage system to provide protec-tion of fixtures such as food processing equipment, hospital and laboratory devicesand storage tanks from contamination due to backflow in the drain line. Air gap pre-vents contamination because back siphonage is broken by the ample free areabetween the threaded inlet and spigot outlet.

SPECIFICATIONJOSAM 88900 Series coated cast iron Air Gap with integrally cast air ports, threadedinlet and extra-heavy spigot outlet.

88900 SERIES AIR GAP

88600 SERIES REDUCING HUB ADAPTER

-40 Galvanized Cast Iron Parts

-40 Galvanized Cast Iron Parts

Available Option

q MEETS ASTM A-74 XH CAST IRON SOIL PIPE STANDARD.

NOTE: INSTALL AIR GAP IN EXPOSED LOCATIONS WHERE MINOR SPLASHING WILL NOT BE A PROBLEM.

Available Option

TYPE NO. PIPE SIZEOUTLET

PIPE SIZEINLET A B q C D LBS.

88603-2 2 3 2 4-1/4 5 4-3/8 588603-2 1/2 2-1/2 3 2-1/2 4-1/4 4-7/8 3-5/8 588604-2 2 4 2 5-1/4 6 4-3/8 688604-2 1/2 2-1/2 4 2-1/2 5-1/4 6 4-1/4 588604-3 3 4 3 5-1/4 6 4-3/8 688606-4 4 6 4 7-1/4 8 4-3/8 9

TYPE NO. A B C D E F LBS.88900-1 1 2 3-1/2 8 2-1/2 4-3/4 488900-2 1-1/2 2 3-1/2 8 3 4-3/4 588900-3 2 3 4-1/2 11-1/2 4 6-1/2 988900-4 3 4 6-1/2 15-1/2 6 8-1/2 1588900-5 4 6 8-1/2 20 8 10-3/8 30

Misc - Traps & Access_08.qxd 5/1/08 4:30 PM Page 264

TRAPS & ACCESSORIESTRAPS & ACCESSORIES

265

MISC.,TRA

PS&

ACCESS.

APPLICATIONFor use between waste outlets and the plumbing drainage system to provide protec-tion of fixtures such as food processing equipment, hospital and laboratory devicesand storage tanks, from contamination due to backflow in the drain line. Air gap pre-vents contamination because back siphonage is broken by the ample free areabetween the threaded inlet and threaded outlet.

SPECIFICATIONJOSAM 88910 Series coated cast iron Air Gap with integrally cast air ports, femalethreaded inlet and outlet.

-40 Galvanized Cast Iron Parts

88910 SERIES AIR GAP

TYPE NO. A B C D E F LBS.88910-1 1/4 3/4 2-1/4 3 1 1-5/8 188910-2 1/2 3/4 2-1/4 3 1 1-5/8 188910-3 1/2 1 2-1/4 3 1 1-5/8 188910-4 3/4 1-1/2 4 5-1/2 2 3 388910-5 1 1-1/2 4 5-1/2 2 3 3

Available Option

APPLICATIONFor use where fresh air is to be introduced into the building drainage system and pro-tection against foreign matter is required. Unit includes steel pipe expansion anchor-ing device and Vandal-Proof spanner locking mechanism.

SPECIFICATIONJOSAM 88950 Series Nikaloy Fresh Air inlet with satin perforated grille, steel pipeexpansion anchoring device and Vandal-Proof spanner locking device.

-2 Satin Finish Bronze Face

88950 SERIES FRESH AIR INLET

Available Option

NOTE: INSTALL AIR GAP IN EXPOSED LOCATIONS WHERE MINOR SPLASHING WILL NOT BE A PROBLEM.

TYPE NO. PIPE SIZE B C DFREE AREA

SQ. IN. LBS.88952 2 5-1/4 8 5-5/8 8 388953 3 5-1/4 8 5-/58 8 388954 4 5-1/4 8 5-5/8 8 388955 5 7-1/4 10 6-5/8 16 488956 6 9-1/4 12 7-5/8 26-3/4 688958 8 11-1/4 14 8-5/8 40 8

Misc - Traps & Access_08.qxd 3/27/08 3:04 PM Page 265

TRAPS & ACCESSORIESTRAPS & ACCESSORIES

266

MIS

C.,T

RAPS

&AC

CESS

.

APPLICATIONFor use where fresh air is to be introduced into the building drainage system andprotection against foreign matter is required. Unit includes convex grille and femalethreaded outlet.

SPECIFICATIONJOSAM 88970 Series Satin Finish Nikaloy Face Fresh Air inlet with satin slotted con-vex grille and female threaded outlet.

88970 SERIES FRESH AIR INLET, CONVEX GRILLE

-8-2 All Bronze with Satin Finish Face-VP Secured Grate, Vandal-Proof Screws

TYPE NO. PIPE SIZE B C DFREE AREA

SQ. IN. LBS.88974 4 6 1-1/8 5-1/2 9 388975 5 7 1-1/4 6-1/2 14 4

Available Options

Misc - Traps & Access_08.qxd 5/1/08 4:30 PM Page 266

267

PVCPVCPVC

PROD

UCTS

Josam PVC Floor Drains, Floor Sinks, and Cleanouts contain the same design features as Josam Cast Iron specification drainage products. The lightweight mate-rial is easy to install.

Polyvinyl Chloride is a rigid material that is chemically non-reactive. It has a broad range of application, from high-volume construction to simple electric wire insulation and coat-ing. PVC possesses good weathering properties, is low-cost and corrosion resistant. It has good electrical insulation properties, dimension and stability at roomtemperature, a good combination of stiffness and impact strength, has flame resistant and fire preventative properties.

WEEPHOLESWeepholes around doubledrainage flange for seepage.

2”, 3”, 4” bottom outlet for Schedule 40solvent weld connection.

9” MEDIUM-DUTY TOPRound non-metallic grate is chemical and temperatureresistant with 24 square inches of free area to acceptheavy flow. Optional half grate for indirect waste andPVC sediment bucket are also available.

CLAMP COLLARClamp works in conjunction withdrainage flange of body to anchordrain in concrete.

TAPPING (Not shown)Auxiliary inlet tapping for trap sealprimer optional. WEJLOC®

Exclusive compression "wedge lock"provides positive non-puncturing bond ofwaterproofing membrane to drain.

PVC Product Features

PVC_08.QXD 4/10/08 1:10 PM Page 267

PVC • Pictorial Selection GuidePVC • Pictorial Selection Guide

268

PVC

PRO

DU

CTS

DRAIN BODIES30000-PVCBody with Collar. For use with all Josam Strainers and Accessories.

Page 269

30300-PVCCombination 3" x 4" Body. For use withall Josam Strainers and Accessories.

Page 269

A STRAINERNikaloy SUPER-FLO® Strainer

Page 270

S STRAINERNikaloy SUPER-FLO® Strainer

Page 270

PVC DRAINS32100-PVC9" Round Top

Page 270

35100-PVC8" Square Cast Iron Top

Page 271

37800-PVC12" Square Cast Iron Top

Page 271

FLOOR SINK49320-PVCBody/Dome Assembly with Full Grate

Page 272

CLEANOUT58360-PVCCombination 3" x 4" Adjustable Floor Cleanout

Page 272

PVC_08.QXD 3/28/08 3:10 PM Page 268

PVCPVC

269

APPLICATIONFor use with all adjustable strainers in ground-floor installations where clamp deviceis not required.

SPECIFICATIONJOSAM 30300-PVC Series PVC Body, threaded to receive all JOSAM adjustablestrainers. Combination 3” x 4” solvent weld bottom outlet fits over 3” or inside 4” Schedule 40 PVC Pipe.

APPLICATIONFor use with all adjustable strainers. Wide flange anchors drain body in concrete andworks in conjunction with the clamp collar to redirect waste through the collar’sweepholes if seepage occurs around the strainer. The WEJLOC® clamp provides anon-puncturing positive bond of the waterproofing membrane to the drain body forapplications where floors with standing water are to be sealed off from areas below.The collar is also invertible for extra vertical strainer adjustment to meet finishedfloor level.

SPECIFICATIONJOSAM 30000-PVC Series PVC Floor Drain, two-piece body with double drainageflange, 1/2” primer tap with plug, WEJLOC® invertible non-puncturing flashing collarwith weepholes, threaded to receive all JOSAM adjustable strainers and solvent weldbottom outlet for Schedule 40 PVC Pipe.

30000-PVC SERIES PVC BODY WITH COLLAR

Available Options-MD PVC Clamp Collar with 3” Socket Connection-49 3/4” Primer Tap

OUTLET:-S Solvent Weld Outlet for Schedule 40 PVC Pipe

Available OptionsOUTLET:

-S Solvent Weld Outlet for Schedule 40 PVC Pipe

FOR USE WITH ALL JOSAMSTRAINERS & ACCESSORIES

FOR USE WITH ALL JOSAMSTRAINERS & ACCESSORIES

TYPE NO. PIPE SIZE LBS.

30300-PVC 3 X 4 1

4"

3 1/2"

4 1/4"

3"

3 3/4"

30300-PVC SERIES COMBINATION 3” X 4” PVC BODY

FOR OUTLET TYPE SPECIFY -STYPE NO. PIPE SIZE LBS.30002-PVC 2 230003-PVC 3 230004-PVC 4 2

PVCPRO

DU

CTS

PVC_08.QXD 5/1/08 4:25 PM Page 269

APPLICATIONFor use in moderate traffic areas such as mechanical rooms and auto garages for anytype of floor construction where a small to medium flow of liquid is anticipated.

SPECIFICATIONJOSAM 32100-PVC Series PVC Floor Drain, two-piece body with double drainage flange,WEJLOC® non-puncturing clamp collar with weepholes, 9” round PVC grate and solventweld bottom outlet for Schedule 40 PVC pipe.

32100-PVC SERIES PVC DRAIN ASSEMBLY, 9” ROUND TOP

-HG Half Grate-B Bucket-49 3/4” Primer Tap-50 1/2” Primer Tap

OUTLET:-S Solvent Weld Outlet for

Schedule 40 PVC Pipe

FOR OUTLET TYPE SPECIFY -STYPE NO. PIPE SIZE LBS.32102-PVC 2 432103-PVC 3 432104-PVC 4 4

Available Options

PVCPVC

270

PVC

PRO

DU

CTS

APPLICATIONFor use in finished areas with pedestrian traffic such as toilet and shower rooms.

•Not SUPER-FLO® Design

A SERIES ROUND NIKALOY SUPER-FLO® STRAINER

TYPE NO. A B C D FREE AREA LBS.5A 5 1-15/16 1-1/8 4-5/8 7.8 26A 6 2-1/4 15/16 5-1/4 11.0 37A 7 2-11/16 1-1/2 6-7/16 13.2 48A 8 2-1/2 7/8 7-1/8 16.2 59A• 9 2-1/4 1 8-1/8 21.1 7

10A• 10 2-1/4 1-1/8 9 28.0 9

Available Options-SS Stainless Steel, 5A, 6A, 7A, 8A-2 Satin Finish Bronze-80 Perforated Stainless Steel

Basket

-CP Chrome Plated, 5A, 6A-J Backwater Valve-VP Secured Grate,

Vandal-Proof Screws

FOR USE WITH 30000-PVCAND 30304-PVC BODIES

FOR USE WITH 30000-PVCAND 30304-PVC BODIES

APPLICATIONFor use in pedestrian traffic areas where square complements construction or floorfinish, such as ceramic tile showers or kitchen floors.

Available Options-SS Stainless Steel, 5S, 6S, 8S-2 Satin Finish Bronze-80 Perforated Stainless Steel

Basket

-CP Chrome Plated, 5S, 6S-J Backwater Valve-VP Secured Grate,

Vandal-Proof Screws

•Not SUPER-FLO® Design

TYPE NO. A B C D FREE AREA LBS.5S 5 1-3/4 7/8 4-1/2 9.1 36S 6 2-1/8 1 5-5/8 13.8 48S 8 2-3/8 1 7-1/2 24.5 99S• 9 2-3/8 1 8-5/8 28.0 10

S SERIES SQUARE NIKALOY SUPER-FLO® STRAINER

PVC_08.QXD 3/28/08 3:10 PM Page 270

PVCPVC

271

FOR OUTLET TYPE SPECIFY -STYPE NO. PIPE SIZE X LBS.35102-PVC 2 3-1/4 2735103-PVC 3 4 2735104-PVC 4 4 27

FOR OUTLET TYPE SPECIFY -STYPE NO. PIPE SIZE X LBS.37802-PVC 2 3-1/4 4937803-PVC 3 4 4937804-PVC 4 4 49

APPLICATIONFor use in heavy traffic areas, such as warehouses and storage rooms, for any type offloor construction where a square top complements construction or floor finish andwhere a small to medium flow of liquid is anticipated.

SPECIFICATIONJOSAM 35100-PVC Series PVC Floor Drain, two-piece body with double drainage flange,non-puncturing clamp collar with weepholes, 8” cast iron square top with heavy-dutyloose-set cast iron grate and solvent weld bottom outlet for Schedule 40 PVC pipe.

-1 Satin Finish Nikaloy Top-2 Satin Finish Bronze Top-15 Chained Grate-49 3/4” Primer Tap-50 1/2” Primer Tap

OUTLET:-S Solvent Weld Outlet for Schedule 40 PVC Pip

Available Options

PVCPRO

DU

CTS

APPLICATIONFor use in medium traffic areas, such as decks and storage rooms, for any type offloor construction where a square top complements construction or floor finish and amedium flow of liquid is anticipated.

SPECIFICATIONJOSAM 37800-PVC Series PVC Floor Drain, two-piece body with flashing flange, shallowbody, non-puncturing flashing collar, weepholes, 12” cast iron square top with heavy-duty loose-set cast iron grate and solvent weld bottom outlet for Schedule 40 PVC pipe.

Available Options-VP Secured Grate, Vandal-Proof Screws-14 Hinged Top-18 Hinged Top with Latching Device-19 C.I. Undergrate with Satin Finish Nikaloy Top-20 C.I. Undergrate with Satin Finish Bronze Top-49 3/4” Primer Tap-50 1/2” Primer Tap

OUTLET:-S Solvent Weld Outlet for Schedule 40 PVC Pipe

35100-PVC SERIES PVC DRAIN ASSEMBLY, 8” SQUARE CAST IRON TOP

37800-PVC SERIES SHALLOW SUMP, 12” SQUARE CAST IRON TOP

8" SQ

2 1/2"

X

SIZEPIPE

9 1/4"

2 1/2"

X

12 1/4" SQ

13 1/8" SQ

SIZEPIPE

GRATE FREE AREA 19.9 SQ. IN.

GRATE FREE AREA 54.6 SQ. IN.

PVC_08.QXD 3/28/08 3:10 PM Page 271

APPLICATIONFor use in finished floors subject to pedestrian and light wheel traffic such as strip mallsand light commercial buildings where a full line sized plug is not required. Top designallows for adjustment.

SPECIFICATIONJOSAM 58630-PVC Series PVC Cleanout, round Nikaloy adjustable top with internalbronze plug. Combination 3” x 4” solvent weld bottom outlet fits over 3” or inside 4” Schedule 40 PVC Pipe.

58360 SERIES ADJUSTABLE FLOOR CLEANOUT

-2 Satin Finish Bronze Top-14 Carpet Cleanout Marker-VP Secured Cover, Vandal-Proof Screws

OUTLET:-S Solvent Weld Outlet for Schedule 40 PVC Pipe

Available Options

FOR OUTLET TYPE SPECIFY -STYPE NO. PIPE SIZE LBS.58360-PVC 3 X 4 4

PVCPVC

272

PVC

PRO

DU

CTS

APPLICATIONFor use in non-traffic areas such as kitchens, supermarkets and hospitals. The 9”square grate and medium sump accept moderate flow and the dome strainer inter-cepts debris which could block the drain line.

SPECIFICATIONJOSAM 49320-PVC Series PVC Floor/Drain Sink, 12” x 12” top with full PVC medium-dutygrate, aluminum dome and solvent weld bottom outlet for Schedule 40 PVC pipe.

49320-PVC SERIES PVC BODY/DOME ASSEMBLY, FULL GRATE

Available Options-LG Less Grate-HG 1/2 Grate-3Q 3/4 Grate-NB Nickel Bronze Traffic Top-3 1/2 Grate, Nickel Bronze-4 3/4 Grate, Nickel Bronze-5 Nikaloy Extra Heavy-Duty Grate & Rim-7 Full Grate with 2-1/2” Center Opening-VP Secured Grate, Vandal-Proof, NB Only-16 Grate with 4” Round Funnel, NB Only-17 Grate with 6” Round Funnel, NB Only-18 Grate with 9” x 3-1/2” Oval Funnel, NB Only-24 Chained Grate, NB Only-50 1/2” Primer Tap

OUTLET:-S Solvent Weld Outlet for Schedule 40 PVC Pipe

FOR OUTLET TYPE SPECIFY -STYPE NO. PIPE SIZE H LBS.49322-PVC 2 6-7/8 849323-PVC 3 7-5/8 849324-PVC 4 7-7/8 8

PVC_08.QXD 5/1/08 4:25 PM Page 272

905

JOSAM COMPANY | www.josam.com

Customer serviCe Centers

Josam West2333 Grant ave

san Lorenzo, Ca 94580510.481.6400 | F 800.995.6726

Josam exeCutive 2501 s Front street

Philadelphia, Pa 19148215.339.5370 | F 800.962.3312

Josam CorPorate525 West Highway 20

michigan City, iN 46360 800.36.Josam | F 800.627.0008

may 2008

eNGiNeeriNG Guide eG-1

Josam Catalog Cover 08.indd 1 5/5/08 12:08:36 PM