EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP...
Transcript of EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP...
![Page 1: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/1.jpg)
EnginEEring and dEsign
guidE
TM
![Page 2: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/2.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
2
2 www.nueraheat.com
LEttEr of introduction ............................................................................................................ 3
airvoLution LinE ......................................................................................................................... 4Power Unit Detail..............................................................................................................................5CSI Spec Sheet .................................................................................................................................608-ft, 1.0 HP AirVolution (MA08XL1006) ......................................................................................... 1010-ft, 1.0 HP AirVolution (MA10XL1006) ......................................................................................... 1212-ft, 1.0 HP AirVolution (MA12XL1006) ......................................................................................... 1414-ft, 1.0 HP AirVolution (MA14XL1006) ......................................................................................... 1616-ft, 1.0 HP AirVolution (MA16XL1006) ......................................................................................... 2018-ft, 1.0 HP AirVolution (MA18XL1006) ......................................................................................... 2220-ft, 1.0 HP AirVolution (MA20XL1006) ......................................................................................... 2424-ft, 1.0 HP AirVolution (MA24XL1006) ......................................................................................... 26
airEco LinE ................................................................................................................................. 28Detail Drawing ................................................................................................................................ 29CSI Spec Sheet ............................................................................................................................... 3006-ft, 0.375 HP AirEco (MA06WB3806/NG/SS/SSNG) .................................................................... 34
airsPan LinE ............................................................................................................................... 361.5HP Power Unit Detail ................................................................................................................. 372HP Power Unit Detail .................................................................................................................... 38CSI Spec Sheet ............................................................................................................................... 3920-ft, 1.5 HP AirSpan (MA20XL1506) .............................................................................................. 4324-ft, 2.0 HP AirSpan (MA24XL2006) .............................................................................................. 45
airsoL LinE .................................................................................................................................. 4716-ft, .33 HP Solar Fan (MA16V0506) ............................................................................................. 4818-ft, .33 HP Solar Fan (MA18V0506) ............................................................................................. 4920-ft, .33 HP Solar Fan (MA20V0506) ............................................................................................. 50
airstar commErciaL LinE ........................................................................................................ 49CSI Spec Sheet ............................................................................................................................... 5016-ft, 0.375 HP Commercial Fan (MA16W0506) ............................................................................. 5418-ft, 0.375 HP Commercial (MA18XL0506) ................................................................................... 5620-ft, 0.375 HP Commercial (MA20S0506) ..................................................................................... 58
airstar LinE ................................................................................................................................ 608-ft, 0.167 HP Fan (MA08XL1606) ................................................................................................... 6110-ft, 0.167 HP Fan (MA10XL1606) ................................................................................................. 6212-ft, 0.167 HP Fan (MA12XL1606) ................................................................................................. 63
samPLE Layouts ......................................................................................................................... 64Riding Arena – Equestrian .............................................................................................................. 64Manufacturing Facility .................................................................................................................... 65Barn – Equestrian/Dairy/Ag ........................................................................................................... 66
tabLEofcontEnts
![Page 3: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/3.jpg)
Thank you for including MacroAir HVLS fans in your project’s specifications. As the invientor of High Volume, Low Speed (HVLS) Technology and the “Big Fan” industrial ceiling fan concept, we are proud to provide the most cost effective, “green” solution to air movement and de-stratification available. The breadth of our product line offers solutions for any size and type of building project. MacroAir Technologies’ state of the art HVLS technology can be found across the world.
We at MacroAir know that, as architects and engineers, you are charged with the task of creating comfortable and energy-efficient environments. By specifying MacroAir fans, you have made the best possible choice, and one that you can stand behind with confidence.
Our HVLS fans offer maximum performance, reliability, and durability, achieved through intelligent, simple, effective engineering and design. MacroAir fans are aesthetically pleasing air moving machines; no gizmos, no gadgets. MacroAir fans provide a long-term service life and are the only HVLSS fans on the market with a 12-year warranty. Third-part certification proves that our fans meet documented performance and CFM levels. MacroAir HVLS fans feature steel construction, anodized aluminum blades, a newly developed hybrid hub system, plus innovative mounting and safety that provide peace of mind and ease of installation. With an operating cost of only pennies per hour, our fans offer an incredible return on investment are truly the “Greenest Fans on Earth”.
The Engineering and Design Guide should give you everything you need to confidently include HVLS fans on your next project.
Included in the Engineering and Design Guide are:-CSI Specification Sheets-Standard Specification Sheets-DWG Drawings-Sample Layout Drawings
Thanks again for choosing MacroAir Technologies!
Eddie boydPresident & CEO
LEttErofintroduction
![Page 4: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/4.jpg)
Using six blades instead of ten, AirVolution™ fans work by generating a large column of air that gently flows down to the ground and outward 360 degrees. The large, slow moving air mass moves throughout the space, mixing and circulating air more efficiently. The remarkably quiet operation of the AirVolution™ fan won’t create unnecessary noise or distraction and the gentle airflow won’t create or stir up dust. Most importantly, the AirVolution™ costs only .31 cents per day to operate and four of them can replace 50 high-speed fans, reducing noise, energy costs, and maintenance.
airvoLution
![Page 5: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/5.jpg)
5
Safe
ty S
yste
m
Mot
or F
ram
e
Gea
rbox
1HP
Mot
or
Uni
vers
al M
ount
ing
Har
dwar
e
Hyb
rid
Hub
Str
ut
Scal
e: 1
:8
Hyb
rid
Hub
Airv
olut
ion
Pow
er U
nit
DO
NO
T SC
ALE
DR
AWIN
G
MAx
xXL1
006 SH
EET
1 O
F 1
6/6/
2011
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
BC
UN
LESS
OTH
ERW
ISE
SPEC
IFIE
D:
SCAL
E: 1
:12
WEI
GH
T:
REV
DW
G.
NO
.
ASIZE
TITL
E:
Mac
roAi
r Te
chno
logi
es79
4 S
Alle
n St
. San
Ber
nard
ino,
CA
9240
8
NAM
ED
ATE
CO
MM
ENTS
:
Q.A
.
MFG
AP
PR
.
ENG
AP
PR
.
CH
ECK
ED
DR
AWN
FIN
ISH
MAT
ERIA
L
INTE
RP
RET
GEO
MET
RIC
TOLE
RAN
CIN
G P
ER:
DIM
ENSI
ON
S AR
E IN
INC
HES
TOLE
RAN
CES
:FR
ACTI
ON
AL.0
10AN
GU
LAR
: MAC
H1
BEN
D
1TW
O P
LAC
E D
ECIM
AL
.01
THR
EE P
LAC
E D
ECIM
AL
.001
APP
LIC
ATIO
N
USE
D O
NN
EXT
ASSY
PR
OP
RIE
TAR
Y AN
D C
ON
FID
ENTI
AL
54
32
1
THE
INFO
RM
ATIO
N C
ON
TAIN
ED IN
TH
IS
DR
AWIN
G IS
TH
E SO
LE P
RO
PER
TY O
F M
acro
Air
TEC
HN
OLO
GIE
S. A
NY
REP
RO
DU
CTI
ON
IN P
AR
T O
R A
S A
WH
OLE
W
ITH
OU
T TH
E W
RIT
TEN
PER
MIS
SIO
N O
F M
acro
Air
TEC
HN
OLO
GIE
S IS
PR
OH
IBIT
ED.
air
voLu
tio
n P
ower
Uni
t
![Page 6: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/6.jpg)
Part 1 gEnEraL 1.1 summary
A. The mounted High Volume Low Speed (HVLS) fans shall be MacroAir Fans. The fan model shall be of the AIRVOLUTION line.
1.2 rEfErEncEs A. American National Standards Institute/Air Movement and Control Association (ANSI/AMCA)
Standard 230-07 - Laboratory Methods of Testing Air Circulating Fans for Rating.
1.3 submittaLs A. Submit under provisions of Section 01 33 00. B. Product Data: Manufacturer’s data sheets on each product to be used, including:
1. Preparation instructions including recommendations.2. Storage and handling requirements including recommendations.3. Provide cut sheets on each product specified showing power and mounting requirements.
1.4 QuaLity assurancE A. Manufacturer Qualifications: Providing sole source for design, engineering, manufacturing
and warranty claims handling. B. Installer Qualifications: Installation services are available upon request by a factory installer.
Any and all work varying from that as described through the installation guide will be outsourced. Installer trained by factory (preferred).
1.5 dELivEry, storagE, and HandLing A. Deliver materials and equipment to project site in manufacture’s shipping carton.B. Store products in manufacturer’s unopened packaging until ready for installation.
1.6 sitE conditions A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits
recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer’s absolute limits.
1.7 coordinationA. The fan shall be capable of receiving a stop command from the fire panel, a VESDA, or any
number of smoke, flame or heat detectors. B. The fans shall be as follows:
1. The fan shall meet the air velocity requirements of FM Global’s 2.0 data sheet forESFR sprinklers.
2. If required by the local fire prevention authority or desired by the purchaser, the fan shallbe wired into the building’s fire suppression system so that the fan will shut off as soon as a fire is detected. To facilitate this, the fan shall include a Variable Frequency Drive (VFD) within the control panel. The low voltage wire and relay needed to accomplish this must be supplied by the Fire Alarm installer.
3. When the fan is shut off, upon fire detection as described above, the fans shall come to acomplete stop in less than 30 seconds.
HvLs fans
manufacturEr:MacroAir Technologies Inc.794 S. Allen Street, San Bernardino, CA 92408-2210 www.macro-air.com
![Page 7: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/7.jpg)
1.8 Warranty A. Manufacturer shall repair or replace defective parts in accordance to the following list of
warranted parts:1. Twelve year service life prorated limited warranty.2. Lifetime on airfoils, hub, and frame.
Part 2 Products2.1 aPProvEd manufacturEs
A. Acceptable Manufacturer: MacroAir Technologies Inc., which is located at: 794 S. Allen Street, San Bernardino, CA 92408-2210 Toll Free Tel: 866-668-3247; Tel: 909-890-2270; Web; www.macro-air.com
B. Substitutions: Not permitted.
2.2 macroair-HvLs cEiLing fansA. Product: AIRVOLUTION HVLS Fan as manufactured by MacroAir Technologies Inc.
1. Complete Unit: The fan shall be ETL certified and built pursuant to constructionguidelines set forth by UL Standards 507, 746C, 1004, 1917 And CSA standards 22.2 No. 71, 22.2 No. 113,22.2, No. 100, 22.2 No. 156. The fan shall include a Variable Frequency Drive (VFD) system specifically programmed for HVLS fans in order to ensure limited sound levels. a) Performance: All fans tested to ANSI/AMCA standard 230-07:
1. Fan Diameter 24 feet: Max Speed Air Displacement Forward- 275,694 CFM.Reverse-192,986 CFM.a) Efficiency at Max Speed: 529.67 CFM/Watt.
2. Fan Diameter 20 feet: Max Speed Air Displacement Forward- 201,805 CFM.Reverse-141,264CFM.a) Efficiency at Max Speed: 454.52 CFM/Watt
3. Fan Diameter 18 feet: Max Speed Air Displacement Forward- 179,015 CFM,Reverse-125,311 CFM.a) Efficiency at Max Speed: 368.35 CFM/Watt
4. Fan diameter 16 feet: Max Speed Air Displacement Forward- 158,911 CFM.Reverse-111,238CFM.a) Efficiency at Max Speed: 305.75 CFM/Watt
5. Fan Diameter 14 feet: Max Speed Air Displacement Forward- 128,010 CFM,Reverse- 89,607 CFM.a) Efficiency at Max Speed: 232.53 CFM/Watt
6. Fan Diameter 12 feet: Max Speed Air Displacement Forward- 97,695 CFM,Reverse-68,387 CFM.a) Efficiency Max Speed: 215.31 CFM/Watt
7. Fan Diameter 10 feet: Max Speed Air Displacement Forward- 83,025 CFM,Reverse-58,118 CFMa) Efficiency at Max Speed: 198.03 CFM/Watt
8. Fan Diameter 8 feet: Max Speed Air Displacement Forward- 53,623 CFM,Reverse-37,585 CFM.a) Efficiency at Max Speed: 104.52 CFM/Watt
9. Decibel output: Less than 65dB measured 20 feet high at fan center.b) Airfoils:
1. Diameter: 8 feet (2440 mm).2. Diameter: 10 feet (3050 mm).3. Diameter: 12 feet (3660 mm).4. Diameter: 14 feet (4270 mm).5. Diameter: 16 feet (4880mm).
![Page 8: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/8.jpg)
6. Diameter: 18 feet (5490mm).7. Diameter: 20 feet (6096mm).8. Diameter: 24 feet (7320mm)9. Number of Airfoil: 6.10. Area Coverage: Up to 18,000 sq. ft (167 sq. m); 100 feet (30 m) from the fan’s center.11. Airfoil Material: 6036-T6 Extruded Aluminum.12. Airfoil Finish: Anodized13. Airfoil Finish: Custom colors available upon request.14. Airfoil Finish: Custom corrosion resistant, heresite colors available.15. Hardware: (2) two 5/16-24 x 2” grade 5 hex bolts.16. Hardware: (2) two 5/16”-inch flat washers.17. Hardware: (2) two 5/16”-inch nylon lock nuts.
c) Motor:1. HP: 1.2. 3 Phase.3. RPM: 17504. Continuous operation up to 104°F5. Service Interval: F6. Motor Frame Finish and Color: Powder coat grey.7. Motor Frame Finish and Color: Custom colors available.
d) Motor Control Panel (MCP) and remote Switchbox:1. Electrical Requirements: 120VAC single phase 50/60 Hz.2. Electrical Requirements: 208-240VAC single phase 50/60 Hz.3. Electrical Requirements: 208-240VAC 3 phase 50/60Hz.4. Electrical Requirements: 380-415VAC 3 phase 50/60 Hz.5. Electrical Requirements: 460-480VAC 3 phase 50/60 Hz.6. Disconnect Switch Amp: 20-25 Amps, Lockable.7. Frame: D56.8. Output: 1HP.9. Remote Control Wall Mounted Switch: NEMA 4/4x.10. Controls: Variable speed switch.11. Controls: On/off, forward and reverse.12. Optional enclosure: NEMA 4/4x.13. Consult factory for special wiring.
e) Gear Reducer:1. 2-Stage Helical.2. Lubed for life.3. Shaft Diameter: 1.250”
f) Mounting and Frame:1. Standard Mount: Universal I-beam clamp with swivel joint and a 7.5”-inch drop.2. (Optional): Glulam Mount: Brackets with a swivel joint and a 7.5”-inch drop.3. (Optional) Extra wide/thick I-beam Mount.4. Mounting to building structural support other than glulam; i.e. angle iron (back to
back), or uni-strut.5. Additional extensions available, up to ten (10) feet in one (1) foot increments.6. Frame: Black powder coated.7. Frame: Welded A369 Steel fabrication.8. SAE Grade 5 hardware.
g) Hybrid Hub:1. Hub Material: 356 T-6 Cast Aluminum.2. Blade Strut Material: 6061 T-6 Aluminum.3. Blade Strut Finish: Black Anodized.
![Page 9: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/9.jpg)
4. Hardware: 3/8-24 x 1 ¾” -inch Grade 5 Hex Bolts, 12x.5. Hardware: 3/8”-inch flat washer (SAE), 12x.6. Hardware: 3/8”-inch nylon lock nut, 12x.
h) Safety System:1. Safety Cable Material: 1/4” x 7 x 19 Aircraft Stainless Steel.2. Safety Cable Finish: Galvanized.3. Guy Wire Material: (x4) 1/8” x 7 x 10 Aircraft Stainless Steel4. Guy Wire Finish: Galvanized.5. Safety Disk Material: Galvanized clear zinc plate.6. Safety disc Finish: Black Powder coat.7. Safety disc Spacer: 3/8”: inch NOM. Sch. 40, 6061-T-6 aluminum pipe.8. Safety Retaining Plate Material: Galvanized clear zinc plate.9. Safety Retaining Plate Finish: Galvanized.10. Blade Retainer Link Material: 10 Galvanized Mild Steel.11. Blade Retainer Link Finish: Zinc.
Part 3 EXEcution 3.1 instaLLation
A. Install units per manufacturer’s written instructions.B. Fan blade height to be a minimum of 10 feet from the floor in accordance with OSHA
and any other governing guidelines.C. All safety and support features must be installed. These include any guy wires and safety
cables as well as blade retainer locking features.D. Adjust unit as required for proper operation in accordance with manufacturer’s installation
instructions.E. Securely anchor units.F. Ensure that operating parts work freely and fit neatly.G. Repair or replace damaged parts, dents, buckles, abrasions or other damage affecting
appearance or serviceability, as acceptable to Architect and/or Engineer.
3.2 PrEParationA. Check accuracy of dimensions indicated for openings to receive fans.B. Check location of utility services.C. Coordinate location and installation of the HVLS Fans.D. Ensure building structural members are sufficient to support the weight and operation of
the fan. Consult professional engineer, registered architect and building codes as required.
3.3 ProtEctionA. Protect finished Work until date of Substantial Completion.B. Touch-up, repair or replace damaged products before Substantial Completion.
3.4 cLEaning A. Clean Work per Section 01 74 00.B. Clean fans per manufacturer’s instructions.C. Remove temporary protective cover at date of Substantial Completion.
![Page 10: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/10.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
10 www.nueraheat.com
airvoLution/8
gEnEraLModel Number ..........................................................MA08XL1006Diameter ...................................................................8 FT / 2.44 Meters Blade Style ................................................................XLNumber of Blades ....................................................6Nominal Horsepower ...............................................1.0 HP / 0.75 kW Hanging Weight .........................................................160 lbs / 72.6 Kg) Shipping Weight (Including MCP, Mounting Hardware) (average) ................................315 lbs / 142.6 KgPower Unit Pallet Dimensions / Weight 26” X 30” X 33.5” / 246 lbs / 0.66 X 0.76X 0.85 Meters / 111.58 Kg Blade Pallet Dimensions/Weight 72” X 25” X 15” / 101 lbs 1.8 X .63 X .38 Meters / 46 Kg
PErformancE (at maX sPEEd)Thrust ...................................................... 17.8 lbfDisplacement (fwd, blowing down) .........53,623 CFM / 25.3 CMS Displacement (rev, blowing up) .........37,585 CFM / 979.3 CMS Maximum Speed ......................................206 RPM Power Usage @ Max. Speed. ....................265 kW Efficiency @ 100% Max. Speed ................148.68 CFM/Watt / 4.21 CMS/Watt Maximum Effective Area .........................4,000 SQ FT / 371.6 m2 Typical Industrial Spacing ...................... 55 FT / 16.76 Meters Typical Dairy Spacing .............................. 50 FT / 15.24 Meters
mounting HardWarEStandard Mount .................................................................................................Universal I-Beam Clamp w/ Swivel Joint and a 7.5” Drop Glulam Mount (Optional) ..................................................................................Brackets w/ Swivel Joint & 7.5” Drop Extra Wide / Thick I-Beam Mount (Optional) ..................................................Upon RequestAdditional Drop Extensions (Optional) .............................................................Up to 10 FT in 1 FT Increments
motorPower ...................................................................................................................1.0 HP / 0.75 kWAmbient Operating Temperature ........................................................................40C°Insulation Class ...................................................................................................FService Factor .....................................................................................................1.15
gEarboXType .....................................................................................................................2-Stage HelicalService Interval ..................................................................................................Lubed For Life
motor controL PanEL (mcP)Standard Power and Max Amp Draw ..................................................................120V, 208-240V 1Ø (11.6A), 208-240V 3Ø (6.7A), 460-480V 3Ø (3.5A)Enclosure ............................................................................................................NEMA 1Disconnect Switch ..............................................................................................20-25 Amp, LockableRemote Control Wall Mounted Switch NEMA 4X ................................................Fwd/Off/Rev w/Speed Control Knob RF Line Filter .......................................................................................................Built In VFD VFD Motor Drive Cable ........................................................................................25 Feet / 7.62 MetersRemote Cable ......................................................................................................100 Feet / 30.48 MetersOptions .................................................................................................................NEMA 4/ 4x Enclosure, 50hz Operation, Line ReactorSpecial Wiring (Variable Speed Model Only) ......................................................Thermostats, fire alarm interface, VESDA, networking etc. (Consult Factory)
safEty comPonEntsBlade Retainer Links (6), Safety Cable, Guy Wires (Ceiling mount only), Patented Inter-Locking Hub
Warranty12 YRS* on Motor, Gearbox & Control Panel.Limited Lifetime on Blades, Hub & Mounting System.
*dB Values Were Obtained by Testing. Specific Applications/Installation values may vary.*Labor Allowance to Remove and Replace in 1st YearContact MacroAir for full Warranty Details. Specifications are subject to change.
8 ft.1HP FanModel No. MA08XL1006
![Page 11: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/11.jpg)
13
3'
2'-
4"
8'
8' A
irvo
lutio
n
DO
NO
T SC
ALE
DR
AWIN
G
MA0
8XL1
006 SH
EET
1 O
F 1
6/6/
2011
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
BC
UN
LESS
OTH
ERW
ISE
SPEC
IFIE
D:
SCAL
E: 1
:25
WEI
GH
T:
REV
DW
G.
NO
.
ASIZE
TITL
E:
Mac
roAi
r Te
chno
logi
es79
4 S
Alle
n St
. San
Ber
nard
ino,
CA
9240
8
NAM
ED
ATE
CO
MM
ENTS
:
Q.A
.
MFG
AP
PR
.
ENG
AP
PR
.
CH
ECK
ED
DR
AWN
FIN
ISH
MAT
ERIA
L
INTE
RP
RET
GEO
MET
RIC
TOLE
RAN
CIN
G P
ER:
DIM
ENSI
ON
S AR
E IN
INC
HES
TOLE
RAN
CES
:FR
ACTI
ON
AL.0
10AN
GU
LAR
: MAC
H1
BEN
D
1TW
O P
LAC
E D
ECIM
AL
.01
THR
EE P
LAC
E D
ECIM
AL
.001
APP
LIC
ATIO
N
USE
D O
NN
EXT
ASSY
PR
OP
RIE
TAR
Y AN
D C
ON
FID
ENTI
AL
THE
INFO
RM
ATIO
N C
ON
TAIN
ED IN
TH
ISD
RAW
ING
IS T
HE
SOLE
PR
OP
ERTY
OF
Mac
roAi
r TE
CH
NO
LOG
IES.
AN
Y R
EPR
OD
UC
TIO
N IN
PAR
T O
R A
S A
WH
OLE
WIT
HO
UT
THE
WR
ITTE
N P
ERM
ISSI
ON
OF
Mac
roAi
r TE
CH
NO
LOG
IES
IS
PR
OH
IBIT
ED.
54
32
1
air
voLu
tio
n/8
![Page 12: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/12.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
12 www.nueraheat.com
airvoLution/10
gEnEraLModel Number ........................................................... MA10XL1006Diameter ................................................................... 10 FT / 3.05 Meters Blade Style ................................................................ XLNumber of Blades .................................................... 6Nominal Horsepower ............................................... 1.0 HP / 0.75 kW Hanging Weight (average) ........................................ 181 lbs / 82.1 Kg Shipping Weight (Including MCP, Mounting Hardware) (average) ................................315 lbs / 142.6 KgPower Unit Pallet Dimensions / Weight 26” X 30” X 33.5” / 246 lbs / 0.66 X 0.76X 0.85 Meters / 111.58 Kg Blade Pallet Dimensions/Weight 72” X 25” X 15” / 101 lbs 1.8 X .63 X .38 Meters / 46 Kg
PErformancE (at maX sPEEd)Thrust ........................................................... 19.7 lbfDisplacement (fwd, blowing down) .............. 83,025 CFM / 2351 Kg Displacement (rev, blowing up] ................... 58,118 CFM / 1645.7 CMS Maximum Speed .......................................... 144 RPM Power Usage @ Max. Speed ......................... 559 kW Efficiency @ 100% Max. Speed ..................... 198.03 CFM/Watt Maximum Effective Area .............................. 5,000 SQ FT / 464.5 m2 Typical Industrial Spacing ............................ 60 FT / 18.29 Meters Maximum dB ................................................ 58*
mounting HardWarEStandard Mount .................................................................................................Universal I-Beam Clamp w/ Swivel Joint and a 7.5” Drop Glulam Mount (Optional) ..................................................................................Brackets w/ Swivel Joint & 7.5” Drop Extra Wide / Thick I-Beam Mount (Optional) ..................................................Upon RequestAdditional Drop Extensions (Optional) .............................................................Up to 10 FT in 1 FT Increments
motorPower ...................................................................................................................1.0 HP / 0.75 kWAmbient Operating Temperature ........................................................................40C°Insulation Class ...................................................................................................FService Factor .....................................................................................................1.15
gEarboXType .....................................................................................................................2-Stage HelicalService Interval ..................................................................................................Lubed For Life
motor controL PanEL (mcP)Standard Power and Max Amp Draw ..................................................................120V, 208-240V 1Ø (11.6A), 208-240V 3Ø (6.7A), 460-480V 3Ø (3.5A)Enclosure ............................................................................................................NEMA 1Disconnect Switch ..............................................................................................20-25 Amp, LockableRemote Control Wall Mounted Switch NEMA 4X ................................................Fwd/Off/Rev w/Speed Control Knob RF Line Filter .......................................................................................................Built In VFD VFD Motor Drive Cable ........................................................................................25 Feet / 7.62 MetersRemote Cable ......................................................................................................100 Feet / 30.48 MetersOptions .................................................................................................................NEMA 4/ 4x Enclosure, 50hz Operation, Line ReactorSpecial Wiring (Variable Speed Model Only) ......................................................Thermostats, fire alarm interface, VESDA, networking etc. (Consult Factory)
safEty comPonEntsBlade Retainer Links (6), Safety Cable, Guy Wires (Ceiling mount only), Patented Inter-Locking Hub
Warranty12 YRS* on Motor, Gearbox & Control Panel.Limited Lifetime on Blades, Hub & Mounting System.
*dB Values Were Obtained by Testing. Specific Applications/Installation values may vary.*Labor Allowance to Remove and Replace in 1st YearContact MacroAir for full Warranty Details. Specifications are subject to change.
10 ft.1HP FanModel No. MA10XL1006
![Page 13: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/13.jpg)
15
10' A
irvo
lutio
n
DO
NO
T SC
ALE
DR
AWIN
G
MA1
0XL1
006 SH
EET
1 O
F 1
6/6/
2011
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
BC
UN
LESS
OTH
ERW
ISE
SPEC
IFIE
D:
SCAL
E: 1
:30
WEI
GH
T:
REV
DW
G.
NO
.
ASIZE
TITL
E:
Mac
roAi
r Te
chno
logi
es79
4 S
Alle
n St
. San
Ber
nard
ino,
CA
9240
8
NAM
ED
ATE
CO
MM
ENTS
:
Q.A
.
MFG
AP
PR
.
ENG
AP
PR
.
CH
ECK
ED
DR
AWN
FIN
ISH
MAT
ERIA
L
INTE
RP
RET
GEO
MET
RIC
TOLE
RAN
CIN
G P
ER:
DIM
ENSI
ON
S AR
E IN
INC
HES
TOLE
RAN
CES
:FR
ACTI
ON
AL.0
10AN
GU
LAR
: MAC
H1
BEN
D
1TW
O P
LAC
E D
ECIM
AL
.01
THR
EE P
LAC
E D
ECIM
AL
.001
APP
LIC
ATIO
N
USE
D O
NN
EXT
ASSY
PR
OP
RIE
TAR
Y AN
D C
ON
FID
ENTI
AL
THE
INFO
RM
ATIO
N C
ON
TAIN
ED IN
TH
ISD
RAW
ING
IS T
HE
SOLE
PR
OP
ERTY
OF
Mac
roAi
r TE
CH
NO
LOG
IES.
AN
Y R
EPR
OD
UC
TIO
N IN
PAR
T O
R A
S A
WH
OLE
WIT
HO
UT
THE
WR
ITTE
N P
ERM
ISSI
ON
OF
Mac
roAi
r TE
CH
NO
LOG
IES
IS
PR
OH
IBIT
ED.
54
32
1
2'-
4"
3'
10'
air
voLu
tio
n/1
0
![Page 14: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/14.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
14 www.nueraheat.com
airvoLution/12
gEnEraLModel Number ........................................................... MA12XL1006Diameter ................................................................... 12 FT / 3.66 Meters Blade Style ................................................................ XLNumber of Blades .................................................... 6Nominal Horsepower ............................................... 1.0 HP / 0.75 kW Hanging Weight (average) ........................................ 190 lbs / 86.2 Kg Shipping Weight (Including MCP, Mounting Hardware) (average) ................................335 lbs / 152.0 Kg Power Unit Pallet Dimensions / Weight 26” X 30” X 33.5” / 246 lbs / 0.66 X 0.76X 0.85 Meters / 111.58 Kg Blade Pallet Dimensions/Weight 72” X 25” X 15” / 111 lbs 1.8 X .63 X .38 Meters / 50.5 Kg
PErformancE (at maX sPEEd)Thrust .......................................................... 27.3 lbf Displacement (fwd, blowing down) ............. 97,695 CFM / 2766.4 CMS Displacement (rev, blowing up) ................... 68,387 CFM / 1936.5 CMS Maximum Speed ........................................... 121 RPM Power Usage @ Max. Speed. ........................ .605 kW Efficiency @ 100% Max. Speed .................... 215.31 CFM/Watt / 6.09 CMS/Watt Maximum Effective Area ............................. 7,000 SQ FT / 650.3 m2
Typical Industrial Spacing ........................... 65 FT / 19.81 Meters Maximum dB ................................................ 58*
mounting HardWarEStandard Mount .................................................................................................Universal I-Beam Clamp w/ Swivel Joint and a 7.5” Drop Glulam Mount (Optional) ..................................................................................Brackets w/ Swivel Joint & 7.5” Drop Extra Wide / Thick I-Beam Mount (Optional) ..................................................Upon RequestAdditional Drop Extensions (Optional) .............................................................Up to 10 FT in 1 FT Increments
motorPower ...................................................................................................................1.0 HP / 0.75 kWAmbient Operating Temperature ........................................................................40C°Insulation Class ...................................................................................................FService Factor .....................................................................................................1.15
gEarboXType .....................................................................................................................2-Stage HelicalService Interval ..................................................................................................Lubed For Life
motor controL PanEL (mcP)Standard Power and Max Amp Draw ..................................................................120V, 208-240V 1Ø (11.6A), 208-240V 3Ø (6.7A), 460-480V 3Ø (3.5A)Enclosure ............................................................................................................NEMA 1Disconnect Switch ..............................................................................................20-25 Amp, LockableRemote Control Wall Mounted Switch NEMA 4X ................................................Fwd/Off/Rev w/Speed Control Knob RF Line Filter .......................................................................................................Built In VFD VFD Motor Drive Cable ........................................................................................25 Feet / 7.62 MetersRemote Cable ......................................................................................................100 Feet / 30.48 MetersOptions .................................................................................................................NEMA 4/ 4x Enclosure, 50hz Operation, Line ReactorSpecial Wiring (Variable Speed Model Only) ......................................................Thermostats, fire alarm interface, VESDA, networking etc. (Consult Factory)
safEty comPonEntsBlade Retainer Links (6), Safety Cable, Guy Wires (Ceiling mount only), Patented Inter-Locking Hub
Warranty12 YRS* on Motor, Gearbox & Control Panel.Limited Lifetime on Blades, Hub & Mounting System.
*dB Values Were Obtained by Testing. Specific Applications/Installation values may vary.*Labor Allowance to Remove and Replace in 1st YearContact MacroAir for full Warranty Details. Specifications are subject to change.
12 ft.1HP FanModel No. MA12XL1006
![Page 15: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/15.jpg)
17
12' A
irvo
lutio
n
DO
NO
T SC
ALE
DR
AWIN
G
MA1
2XL1
006 SH
EET
1 O
F 1
6/6/
2011
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
BC
UN
LESS
OTH
ERW
ISE
SPEC
IFIE
D:
SCAL
E: 1
:35
WEI
GH
T:
REV
DW
G.
NO
.
ASIZE
TITL
E:
Mac
roAi
r Te
chno
logi
es79
4 S
Alle
n St
. San
Ber
nard
ino,
CA
9240
8
NAM
ED
ATE
CO
MM
ENTS
:
Q.A
.
MFG
AP
PR
.
ENG
AP
PR
.
CH
ECK
ED
DR
AWN
FIN
ISH
MAT
ERIA
L
INTE
RP
RET
GEO
MET
RIC
TOLE
RAN
CIN
G P
ER:
DIM
ENSI
ON
S AR
E IN
INC
HES
TOLE
RAN
CES
:FR
ACTI
ON
AL.0
10AN
GU
LAR
: MAC
H1
BEN
D
1TW
O P
LAC
E D
ECIM
AL
.01
THR
EE P
LAC
E D
ECIM
AL
.001
APP
LIC
ATIO
N
USE
D O
NN
EXT
ASSY
PR
OP
RIE
TAR
Y AN
D C
ON
FID
ENTI
AL
THE
INFO
RM
ATIO
N C
ON
TAIN
ED IN
TH
ISD
RAW
ING
IS T
HE
SOLE
PR
OP
ERTY
OF
Mac
roAi
r TE
CH
NO
LOG
IES.
AN
Y R
EPR
OD
UC
TIO
N IN
PAR
T O
R A
S A
WH
OLE
WIT
HO
UT
THE
WR
ITTE
N P
ERM
ISSI
ON
OF
Mac
roAi
r TE
CH
NO
LOG
IES
IS
PR
OH
IBIT
ED.
54
32
1
2'-
4"
3'
12'
air
voLu
tio
n/1
2
![Page 16: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/16.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
16 www.nueraheat.com
airvoLution/14
gEnEraLModel Number ........................................................... MA14XL1006Diameter ................................................................... 14 FT / 4.27 Meters Blade Style ................................................................ XLNumber of Blades .................................................... 6Nominal Horsepower ............................................... 1.0 HP / 0.75 kW Hanging Weight (average) ........................................ 194 lbs / 88.0 Kg Shipping Weight (Including MCP, Mounting Hardware) (average) ................................355 lbs / 161.0 Kg Power Unit Pallet Dimensions / Weight 26” X 30” X 33.5” / 246 lbs / 0.66 X 0.76X 0.85 Meters / 111.58 Kg Blade Pallet Dimensions/Weight 96” X 25” X 15” / 134 lbs 2.4 X .63 X .38 Meters / 60.9 Kg
PErformancE (at maX sPEEd)Thrust .......................................................... 34.6 lbfDisplacement (fwd, blowing down) ............. 128,010 CFM / 3624.8 CMS Displacement (rev, blowing up) ................... 89,607 CFM / 2537.4 CMS Maximum Speed ........................................... 104 RPM Power Usage @ Max. Speed. ........................ 0.734 kW Efficiency @ 100% Max. Speed .................... 232.53 CFM/Watt / 5.59 CMS/Watt Maximum Effective Area ............................. 8,000 SQ FT / 743.3 m2 Typical Industrial Spacing ........................... 70 FT / 21.34 Meters Maximum dB ................................................ 58*
mounting HardWarEStandard Mount .................................................................................................Universal I-Beam Clamp w/ Swivel Joint and a 7.5” Drop Glulam Mount (Optional) ..................................................................................Brackets w/ Swivel Joint & 7.5” Drop Extra Wide / Thick I-Beam Mount (Optional) ..................................................Upon RequestAdditional Drop Extensions (Optional) .............................................................Up to 10 FT in 1 FT Increments
motorPower ...................................................................................................................1.0 HP / 0.75 kWAmbient Operating Temperature ........................................................................40C°Insulation Class ...................................................................................................FService Factor .....................................................................................................1.15
gEarboXType .....................................................................................................................2-Stage HelicalService Interval ..................................................................................................Lubed For Life
motor controL PanEL (mcP)Standard Power and Max Amp Draw ..................................................................120V, 208-240V 1Ø (11.6A), 208-240V 3Ø (6.7A), 460-480V 3Ø (3.5A)Enclosure ............................................................................................................NEMA 1Disconnect Switch ..............................................................................................20-25 Amp, LockableRemote Control Wall Mounted Switch NEMA 4X ................................................Fwd/Off/Rev w/Speed Control Knob RF Line Filter .......................................................................................................Built In VFD VFD Motor Drive Cable ........................................................................................25 Feet / 7.62 MetersRemote Cable ......................................................................................................100 Feet / 30.48 MetersOptions .................................................................................................................NEMA 4/ 4x Enclosure, 50hz Operation, Line ReactorSpecial Wiring (Variable Speed Model Only) ......................................................Thermostats, fire alarm interface, VESDA, networking etc. (Consult Factory)
safEty comPonEntsBlade Retainer Links (6), Safety Cable, Guy Wires (Ceiling mount only), Patented Inter-Locking Hub
Warranty12 YRS* on Motor, Gearbox & Control Panel.Limited Lifetime on Blades, Hub & Mounting System.
*dB Values Were Obtained by Testing. Specific Applications/Installation values may vary.*Labor Allowance to Remove and Replace in 1st YearContact MacroAir for full Warranty Details. Specifications are subject to change.
14 ft.1HP FanModel No. MA14XL1006
![Page 17: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/17.jpg)
19
14' A
irvo
lutio
n
DO
NO
T SC
ALE
DR
AWIN
G
MA1
4XL1
006 SH
EET
1 O
F 1
6/6/
2011
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
BC
UN
LESS
OTH
ERW
ISE
SPEC
IFIE
D:
SCAL
E: 1
:40
WEI
GH
T:
REV
DW
G.
NO
.
ASIZE
TITL
E:
Mac
roAi
r Te
chno
logi
es79
4 S
Alle
n St
. San
Ber
nard
ino,
CA
9240
8
NAM
ED
ATE
CO
MM
ENTS
:
Q.A
.
MFG
AP
PR
.
ENG
AP
PR
.
CH
ECK
ED
DR
AWN
FIN
ISH
MAT
ERIA
L
INTE
RP
RET
GEO
MET
RIC
TOLE
RAN
CIN
G P
ER:
DIM
ENSI
ON
S AR
E IN
INC
HES
TOLE
RAN
CES
:FR
ACTI
ON
AL.0
10AN
GU
LAR
: MAC
H1
BEN
D
1TW
O P
LAC
E D
ECIM
AL
.01
THR
EE P
LAC
E D
ECIM
AL
.001
APP
LIC
ATIO
N
USE
D O
NN
EXT
ASSY
PR
OP
RIE
TAR
Y AN
D C
ON
FID
ENTI
AL
THE
INFO
RM
ATIO
N C
ON
TAIN
ED IN
TH
ISD
RAW
ING
IS T
HE
SOLE
PR
OP
ERTY
OF
Mac
roAi
r TE
CH
NO
LOG
IES.
AN
Y R
EPR
OD
UC
TIO
N IN
PAR
T O
R A
S A
WH
OLE
WIT
HO
UT
THE
WR
ITTE
N P
ERM
ISSI
ON
OF
Mac
roAi
r TE
CH
NO
LOG
IES
IS
PR
OH
IBIT
ED.
54
32
1
3' 2
'-4"
14'
air
voLu
tio
n/1
4
![Page 18: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/18.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
18 www.nueraheat.com
airvoLution/16
gEnEraLModel Number ........................................................... MA16XL1006Diameter ................................................................... 16 FT / 4.88 Meters Blade Style ................................................................ XLNumber of Blades .................................................... 6Nominal Horsepower ............................................... 1.0 HP / 0.75 kW Hanging Weight (average) ........................................ 208 lbs / 94.3 Kg Shipping Weight (Including MCP, Mounting Hardware) (average) ................................365 lbs / 165.6 Kg Power Unit Pallet Dimensions / Weight 26” X 30” X 33.5” / 246 lbs / 0.66 X 0.76X 0.85 Meters / 111.58 Kg Blade Pallet Dimensions/Weight 96” X 25” X 15” / 139 lbs 2.4 X .63 X .38 Meters / 63.2 Kg
PErformancE (at maX sPEEd)Thrust .......................................................... 40.7 lbf Displacement (fwd, blowing down) ............. 158,911 CFM / 4499.8 CMS Displacement (rev, blowing up) ................... 111,238 CFM / 318.2 CMMS Maximum Speed ........................................... 88 RPM Power Usage @ Max. Speed. ........................ .693 kW Efficiency @ 100% Max. Speed .................... 305.75 CFM/Watt / 8.65 CMS/Watt Maximum Effective Area ............................. 15,000 SQ FT / 1393.5 m2 Typical Industrial Spacing ........................... 90 FT / 27.43 Meters Maximum dB ................................................ 58*
mounting HardWarEStandard Mount .................................................................................................Universal I-Beam Clamp w/ Swivel Joint and a 7.5” Drop Glulam Mount (Optional) ..................................................................................Brackets w/ Swivel Joint & 7.5” Drop Extra Wide / Thick I-Beam Mount (Optional) ..................................................Upon RequestAdditional Drop Extensions (Optional) .............................................................Up to 10 FT in 1 FT Increments
motorPower ...................................................................................................................1.0 HP / 0.75 kWAmbient Operating Temperature ........................................................................40C°Insulation Class ...................................................................................................FService Factor .....................................................................................................1.15
gEarboXType .....................................................................................................................2-Stage HelicalService Interval ..................................................................................................Lubed For Life
motor controL PanEL (mcP)Standard Power and Max Amp Draw ..................................................................120V, 208-240V 1Ø (11.6A), 208-240V 3Ø (6.7A), 460-480V 3Ø (3.5A)Enclosure ............................................................................................................NEMA 1Disconnect Switch ..............................................................................................20-25 Amp, LockableRemote Control Wall Mounted Switch NEMA 4X ................................................Fwd/Off/Rev w/Speed Control Knob RF Line Filter .......................................................................................................Built In VFD VFD Motor Drive Cable ........................................................................................25 Feet / 7.62 MetersRemote Cable ......................................................................................................100 Feet / 30.48 MetersOptions .................................................................................................................NEMA 4/ 4x Enclosure, 50hz Operation, Line ReactorSpecial Wiring (Variable Speed Model Only) ......................................................Thermostats, fire alarm interface, VESDA, networking etc. (Consult Factory)
safEty comPonEntsBlade Retainer Links (6), Safety Cable, Guy Wires (Ceiling mount only), Patented Inter-Locking Hub
Warranty12 YRS* on Motor, Gearbox & Control Panel.Limited Lifetime on Blades, Hub & Mounting System.
*dB Values Were Obtained by Testing. Specific Applications/Installation values may vary.*Labor Allowance to Remove and Replace in 1st YearContact MacroAir for full Warranty Details. Specifications are subject to change.
16 ft.1HP FanModel No. MA16XL1006
![Page 19: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/19.jpg)
23
16' A
irvo
lutio
n
DO
NO
T SC
ALE
DR
AWIN
G
MA1
6XL1
006 SH
EET
1 O
F 1
6/6/
2011
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
BC
UN
LESS
OTH
ERW
ISE
SPEC
IFIE
D:
SCAL
E: 1
:45
WEI
GH
T:
REV
DW
G.
NO
.
ASIZE
TITL
E:
Mac
roAi
r Te
chno
logi
es79
4 S
Alle
n St
. San
Ber
nard
ino,
CA
9240
8
NAM
ED
ATE
CO
MM
ENTS
:
Q.A
.
MFG
AP
PR
.
ENG
AP
PR
.
CH
ECK
ED
DR
AWN
FIN
ISH
MAT
ERIA
L
INTE
RP
RET
GEO
MET
RIC
TOLE
RAN
CIN
G P
ER:
DIM
ENSI
ON
S AR
E IN
INC
HES
TOLE
RAN
CES
:FR
ACTI
ON
AL.0
10AN
GU
LAR
: MAC
H1
BEN
D
1TW
O P
LAC
E D
ECIM
AL
.01
THR
EE P
LAC
E D
ECIM
AL
.001
APP
LIC
ATIO
N
USE
D O
NN
EXT
ASSY
PR
OP
RIE
TAR
Y AN
D C
ON
FID
ENTI
AL
THE
INFO
RM
ATIO
N C
ON
TAIN
ED IN
TH
ISD
RAW
ING
IS T
HE
SOLE
PR
OP
ERTY
OF
Mac
roAi
r TE
CH
NO
LOG
IES.
AN
Y R
EPR
OD
UC
TIO
N IN
PAR
T O
R A
S A
WH
OLE
WIT
HO
UT
THE
WR
ITTE
N P
ERM
ISSI
ON
OF
Mac
roAi
r TE
CH
NO
LOG
IES
IS
PR
OH
IBIT
ED.
54
32
1
3' 2
'-4"
16'
air
voLu
tio
n/1
6
![Page 20: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/20.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
20 www.nueraheat.com
airvoLution/18
gEnEraLModel Number ........................................................... MA18XL1006Diameter ................................................................... 18 FT / 5.49 Meters Blade Style ................................................................ XLNumber of Blades .................................................... 6Nominal Horsepower ............................................... 1.0 HP / 0.75 kW Hanging Weight (average) ........................................ 222 lbs / 100.7 Kg Shipping Weight (Including MCP, Mounting Hardware) (average) ................................396 lbs / 179.6 Kg Power Unit Pallet Dimensions / Weight 26” X 30” X 33.5” / 246 lbs / 0.66 X 0.76X 0.85 Meters / 111.58 KgBlade Pallet Dimensions/Weight 108” X 25” X 15” / 146 lbs 2.7 X .63 X .38 Meters / 66.4 Kg
PErformancE (at maX sPEEd)Thrust .......................................................... 40.8 lbf Displacement (fwd, blowing down) ............. 179,015 CFM / 5069.1 CMS Displacement (rev, blowing up) ................... 125,311 CFM / 3548.4 CMS Maximum Speed ........................................... 71 RPM Power Usage @ Max. Speed. ........................ .648 kW Efficiency @ 100% Max. Speed .................... 368.35 CFM/Watt /10.43 CMS/Watt Maximum Effective Area ............................. 15,000 SQ FT / 1393.5 m2 Typical Industrial Spacing ........................... 90 FT / 27.43 Meters Maximum dB ................................................ 58*
mounting HardWarEStandard Mount .................................................................................................Universal I-Beam Clamp w/ Swivel Joint and a 7.5” Drop Glulam Mount (Optional) ..................................................................................Brackets w/ Swivel Joint & 7.5” Drop Extra Wide / Thick I-Beam Mount (Optional) ..................................................Upon RequestAdditional Drop Extensions (Optional) .............................................................Up to 10 FT in 1 FT Increments
motorPower ...................................................................................................................1.0 HP / 0.75 kWAmbient Operating Temperature ........................................................................40C°Insulation Class ...................................................................................................FService Factor .....................................................................................................1.15
gEarboXType .....................................................................................................................2-Stage HelicalService Interval ..................................................................................................Lubed For Life
motor controL PanEL (mcP)Standard Power and Max Amp Draw ..................................................................120V, 208-240V 1Ø (11.6A), 208-240V 3Ø (6.7A), 460-480V 3Ø (3.5A)Enclosure ............................................................................................................NEMA 1Disconnect Switch ..............................................................................................20-25 Amp, LockableRemote Control Wall Mounted Switch NEMA 4X ................................................Fwd/Off/Rev w/Speed Control Knob RF Line Filter .......................................................................................................Built In VFD VFD Motor Drive Cable ........................................................................................25 Feet / 7.62 MetersRemote Cable ......................................................................................................100 Feet / 30.48 MetersOptions .................................................................................................................NEMA 4/ 4x Enclosure, 50hz Operation, Line ReactorSpecial Wiring (Variable Speed Model Only) ......................................................Thermostats, fire alarm interface, VESDA, networking etc. (Consult Factory)
safEty comPonEntsBlade Retainer Links (6), Safety Cable, Guy Wires (Ceiling mount only), Patented Inter-Locking Hub
Warranty12 YRS* on Motor, Gearbox & Control Panel.Limited Lifetime on Blades, Hub & Mounting System.
*dB Values Were Obtained by Testing. Specific Applications/Installation values may vary.*Labor Allowance to Remove and Replace in 1st YearContact MacroAir for full Warranty Details. Specifications are subject to change.
18 ft. 1HP Fan Model No. MA18XL1006
![Page 21: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/21.jpg)
25
18' A
irvo
lutio
n
DO
NO
T SC
ALE
DR
AWIN
G
MA1
8XL1
006 SH
EET
1 O
F 1
6/6/
2011
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
BC
UN
LESS
OTH
ERW
ISE
SPEC
IFIE
D:
SCAL
E: 1
:55
WEI
GH
T:
REV
DW
G.
NO
.
ASIZE
TITL
E:
Mac
roAi
r Te
chno
logi
es79
4 S
Alle
n St
. San
Ber
nard
ino,
CA
9240
8
NAM
ED
ATE
CO
MM
ENTS
:
Q.A
.
MFG
AP
PR
.
ENG
AP
PR
.
CH
ECK
ED
DR
AWN
FIN
ISH
MAT
ERIA
L
INTE
RP
RET
GEO
MET
RIC
TOLE
RAN
CIN
G P
ER:
DIM
ENSI
ON
S AR
E IN
INC
HES
TOLE
RAN
CES
:FR
ACTI
ON
AL.0
10AN
GU
LAR
: MAC
H1
BEN
D
1TW
O P
LAC
E D
ECIM
AL
.01
THR
EE P
LAC
E D
ECIM
AL
.001
APP
LIC
ATIO
N
USE
D O
NN
EXT
ASSY
PR
OP
RIE
TAR
Y AN
D C
ON
FID
ENTI
AL
THE
INFO
RM
ATIO
N C
ON
TAIN
ED IN
TH
ISD
RAW
ING
IS T
HE
SOLE
PR
OP
ERTY
OF
Mac
roAi
r TE
CH
NO
LOG
IES.
AN
Y R
EPR
OD
UC
TIO
N IN
PAR
T O
R A
S A
WH
OLE
WIT
HO
UT
THE
WR
ITTE
N P
ERM
ISSI
ON
OF
Mac
roAi
r TE
CH
NO
LOG
IES
IS
PR
OH
IBIT
ED.
54
32
1
2'-
4"
3'
18'
air
voLu
tio
n/1
8
![Page 22: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/22.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
22 www.nueraheat.com
airvoLution/20
gEnEraLModel Number ........................................................... MA20XL1006Diameter ................................................................... 20 FT / 6.07 Meters Blade Style ................................................................ XLNumber of Blades .................................................... 6Nominal Horsepower ............................................... 1.0 HP / 0.75 kW Hanging Weight (average) ........................................ 232 lbs / 105.2 Kg Shipping Weight (Including MCP, Mounting Hardware) (average) ................................406 lbs / 184.2 Kg Power Unit Pallet Dimensions / Weight 26” X 30” X 33.5” / 246 lbs / 0.66 X 0.76X 0.85 Meters / 111.58 Kg Blade Pallet Dimensions/Weight 120” X 25” X 15” / 152 lbs / 3.0 X .63 X .38 Meters / 69.1 Kg
PErformancE (at maX sPEEd)Thrust .......................................................... 42.0 lbf Displacement (fwd, blowing down) ............. 201,805 CFM / 5714.5 CMS Displacement (rev, blowing up) ................... 141,264 CFM / 4000.2 CMS Maximum Speed ........................................... 60 RPM Power Usage @ Max. Speed. ........................ .592 kW Efficiency @ 100% Max. Speed .................... 368.35 CFM/Watt /10.43 CMS/ Watt Maximum Effective Area ............................. 15,000 SQ FT / 1393.5 m2 Typical Industrial Spacing ........................... 95 FT / 29.57 Meters Maximum dB ................................................ 58*
mounting HardWarEStandard Mount .................................................................................................Universal I-Beam Clamp w/ Swivel Joint and a 7.5” Drop Glulam Mount (Optional) ..................................................................................Brackets w/ Swivel Joint & 7.5” Drop Extra Wide / Thick I-Beam Mount (Optional) ..................................................Upon RequestAdditional Drop Extensions (Optional) .............................................................Up to 10 FT in 1 FT Increments
motorPower ...................................................................................................................1.0 HP / 0.75 kWAmbient Operating Temperature ........................................................................40C°Insulation Class ...................................................................................................FService Factor .....................................................................................................1.15
gEarboXType .....................................................................................................................2-Stage HelicalService Interval ..................................................................................................Lubed For Life
motor controL PanEL (mcP)Standard Power and Max Amp Draw ..................................................................120V, 208-240V 1Ø (11.6A), 208-240V 3Ø (6.7A), 460-480V 3Ø (3.5A)Enclosure ............................................................................................................NEMA 1Disconnect Switch ..............................................................................................20-25 Amp, LockableRemote Control Wall Mounted Switch NEMA 4X ................................................Fwd/Off/Rev w/Speed Control Knob RF Line Filter .......................................................................................................Built In VFD VFD Motor Drive Cable ........................................................................................25 Feet / 7.62 MetersRemote Cable ......................................................................................................100 Feet / 30.48 MetersOptions .................................................................................................................NEMA 4/ 4x Enclosure, 50hz Operation, Line ReactorSpecial Wiring (Variable Speed Model Only) ......................................................Thermostats, fire alarm interface, VESDA, networking etc. (Consult Factory)
safEty comPonEntsBlade Retainer Links (6), Safety Cable, Guy Wires (Ceiling mount only), Patented Inter-Locking Hub
Warranty12 YRS* on Motor, Gearbox & Control Panel.Limited Lifetime on Blades, Hub & Mounting System.
*dB Values Were Obtained by Testing. Specific Applications/Installation values may vary.*Labor Allowance to Remove and Replace in 1st YearContact MacroAir for full Warranty Details. Specifications are subject to change.
20 ft. 1HP Fan Model No. MA20XL1006
![Page 23: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/23.jpg)
27
20' A
irvo
lutio
n
DO
NO
T SC
ALE
DR
AWIN
G
MA2
0XL1
006 SH
EET
1 O
F 1
6/6/
2011
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
BC
UN
LESS
OTH
ERW
ISE
SPEC
IFIE
D:
SCAL
E: 1
:60
WEI
GH
T:
REV
DW
G.
NO
.
ASIZE
TITL
E:
Mac
roAi
r Te
chno
logi
es79
4 S
Alle
n St
. San
Ber
nard
ino,
CA
9240
8
NAM
ED
ATE
CO
MM
ENTS
:
Q.A
.
MFG
AP
PR
.
ENG
AP
PR
.
CH
ECK
ED
DR
AWN
FIN
ISH
MAT
ERIA
L
INTE
RP
RET
GEO
MET
RIC
TOLE
RAN
CIN
G P
ER:
DIM
ENSI
ON
S AR
E IN
INC
HES
TOLE
RAN
CES
:FR
ACTI
ON
AL.0
10AN
GU
LAR
: MAC
H1
BEN
D
1TW
O P
LAC
E D
ECIM
AL
.01
THR
EE P
LAC
E D
ECIM
AL
.001
APP
LIC
ATIO
N
USE
D O
NN
EXT
ASSY
PR
OP
RIE
TAR
Y AN
D C
ON
FID
ENTI
AL
THE
INFO
RM
ATIO
N C
ON
TAIN
ED IN
TH
ISD
RAW
ING
IS T
HE
SOLE
PR
OP
ERTY
OF
Mac
roAi
r TE
CH
NO
LOG
IES.
AN
Y R
EPR
OD
UC
TIO
N IN
PAR
T O
R A
S A
WH
OLE
WIT
HO
UT
THE
WR
ITTE
N P
ERM
ISSI
ON
OF
Mac
roAi
r TE
CH
NO
LOG
IES
IS
PR
OH
IBIT
ED.
54
32
1
2'-
4"
3'
20'
air
voLu
tio
n/2
0
![Page 24: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/24.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
24 www.nueraheat.com
airvoLution/24
gEnEraLModel Number ........................................................... MA24XL1006Diameter ................................................................... 24 FT / 7.32 Meters Blade Style ................................................................ XLNumber of Blades .................................................... 6Nominal Horsepower ............................................... 1.0 HP / 0.75 kW Hanging Weight (average) ........................................ 240 lbs/ 108.8 Kg Shipping Weight (Including MCP, Mounting Hardware) (average) ................................436 lbs / 197.8 Kg Power Unit Pallet Dimensions / Weight 26” X 30” X 33.5” / 246 lbs / 0.66 X 0.76X 0.85 Meters / 111.58 KgBlade Pallet Dimensions/Weight 144” X 25” X 15” / 191 lbs / 3.6 X .63 X .38 Meters / 86.8 Kg
PErformancE (at maX sPEEd)Thrust .......................................................... 42.0 lbf Displacement (fwd, blowing down) ............. 275,694 CFM / 7806.8 CMS Displacement (rev, blowing up) ................... 192,986 CFM / 5464.8 CMS Maximum Speed ........................................... 50 RPM Power Usage @ Max. Speed. ........................ .694 kW Efficiency @ 100% Max. Speed .................... 529.67 CFM/Watt / 15 CMS/Watt Maximum Effective Area ............................. 18,000 SQ FT / 1673.3 m2 Typical Industrial Spacing ........................... 100 FT / 30.48 Meters Maximum dB ................................................ 58*
mounting HardWarEStandard Mount .................................................................................................Universal I-Beam Clamp w/ Swivel Joint and a 7.5” Drop Glulam Mount (Optional) ..................................................................................Brackets w/ Swivel Joint & 7.5” Drop Extra Wide / Thick I-Beam Mount (Optional) ..................................................Upon RequestAdditional Drop Extensions (Optional) .............................................................Up to 10 FT in 1 FT Increments
motorPower ...................................................................................................................1.0 HP / 0.75 kWAmbient Operating Temperature ........................................................................40C°Insulation Class ...................................................................................................FService Factor .....................................................................................................1.15
gEarboXType .....................................................................................................................2-Stage HelicalService Interval ..................................................................................................Lubed For Life
motor controL PanEL (mcP)Standard Power and Max Amp Draw ..................................................................120V, 208-240V 1Ø (11.6A), 208-240V 3Ø (6.7A), 460-480V 3Ø (3.5A)Enclosure ............................................................................................................NEMA 1Disconnect Switch ..............................................................................................20-25 Amp, LockableRemote Control Wall Mounted Switch NEMA 4X ................................................Fwd/Off/Rev w/Speed Control Knob RF Line Filter .......................................................................................................Built In VFD VFD Motor Drive Cable ........................................................................................25 Feet / 7.62 MetersRemote Cable ......................................................................................................100 Feet / 30.48 MetersOptions .................................................................................................................NEMA 4/ 4x Enclosure, 50hz Operation, Line ReactorSpecial Wiring (Variable Speed Model Only) ......................................................Thermostats, fire alarm interface, VESDA, networking etc. (Consult Factory)
safEty comPonEntsBlade Retainer Links (6), Safety Cable, Guy Wires (Ceiling mount only), Patented Inter-Locking Hub
Warranty12 YRS* on Motor, Gearbox & Control Panel.Limited Lifetime on Blades, Hub & Mounting System.
*dB Values Were Obtained by Testing. Specific Applications/Installation values may vary.*Labor Allowance to Remove and Replace in 1st YearContact MacroAir for full Warranty Details. Specifications are subject to change.
24 ft. 1HP Fan Model No. MA24XL1006
![Page 25: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/25.jpg)
29
24' A
irvo
lutio
n
DO
NO
T SC
ALE
DR
AWIN
G
MA2
4XL1
006 SH
EET
1 O
F 1
6/6/
2011
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
BC
UN
LESS
OTH
ERW
ISE
SPEC
IFIE
D:
SCAL
E: 1
:75
WEI
GH
T:
REV
DW
G.
NO
.
ASIZE
TITL
E:
Mac
roAi
r Te
chno
logi
es79
4 S
Alle
n St
. San
Ber
nard
ino,
CA
9240
8
NAM
ED
ATE
CO
MM
ENTS
:
Q.A
.
MFG
AP
PR
.
ENG
AP
PR
.
CH
ECK
ED
DR
AWN
FIN
ISH
MAT
ERIA
L
INTE
RP
RET
GEO
MET
RIC
TOLE
RAN
CIN
G P
ER:
DIM
ENSI
ON
S AR
E IN
INC
HES
TOLE
RAN
CES
:FR
ACTI
ON
AL.0
10AN
GU
LAR
: MAC
H1
BEN
D
1TW
O P
LAC
E D
ECIM
AL
.01
THR
EE P
LAC
E D
ECIM
AL
.001
APP
LIC
ATIO
N
USE
D O
NN
EXT
ASSY
PR
OP
RIE
TAR
Y AN
D C
ON
FID
ENTI
AL
THE
INFO
RM
ATIO
N C
ON
TAIN
ED IN
TH
ISD
RAW
ING
IS T
HE
SOLE
PR
OP
ERTY
OF
Mac
roAi
r TE
CH
NO
LOG
IES.
AN
Y R
EPR
OD
UC
TIO
N IN
PAR
T O
R A
S A
WH
OLE
WIT
HO
UT
THE
WR
ITTE
N P
ERM
ISSI
ON
OF
Mac
roAi
r TE
CH
NO
LOG
IES
IS
PR
OH
IBIT
ED.
54
32
1
2'-
4"
3'
24'
air
voLu
tio
n/2
4
![Page 26: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/26.jpg)
The AirEco produces up to 26,432 cubic feet of air per minute, more than any other fan in its class, and yet operates for less than 25¢ per day. Other features of the AirEco include single or variable speed options, easy mounting, and versatile tilt positioning to provide optimal air movement.
airEco
![Page 27: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/27.jpg)
MA
06W
B38
06-N
G/S
S/N
GSS
AIR
ECO
WA
LL-M
OU
NT
HVL
S FA
N6
FOO
T D
IAM
ETER
3/8
HP,
6 B
LAD
E
OVE
RH
EAD
VIE
W
LEFT
VIE
WFR
ON
T VI
EWR
IGH
T VI
EW
ALL
INFO
RM
ATIO
N C
ON
TAIN
ED IN
TH
IS D
RAW
ING
IS P
RO
PER
TY O
F M
ACR
OAI
R T
ECH
NO
LOG
IES,
INC
.P
ERM
ISSI
ON
IS G
RAN
TED
ON
LY F
OR
LIM
ITED
USE
IN A
RC
HIT
ECTU
RAL
/EN
GIN
EER
ING
DR
AWIN
GS.
ANY
OTH
ER D
ISTR
IBU
TIO
N R
EQU
IRES
PR
IOR
PER
MIS
SIO
N O
F M
ACR
OAI
R T
ECH
NO
LOG
IES,
INC
.C
AD D
RAW
ING
S AC
TUAL
SIZ
E (1
:1).
DO
NO
T R
ESIZ
E; R
EQU
EST
OTH
ER F
AN S
IZES
FR
OM
MAC
RO
AIR
TEC
HN
OLO
GIE
S, IN
C.
![Page 28: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/28.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
28 www.nueraheat.com
Part 1 gEnEraL 1.1 summary
A. The mounted High Volume Low Speed (HVLS) fans shall be MacroAir Fans. The fan model shall be of the AIRECO line.
1.2 rEfErEncEs A. American National Standards Institute/Air Movement and Control Association (ANSI/AMCA)
Standard 230-07 - Laboratory Methods of Testing Air Circulating Fans for Rating.
1.3 submittaLs A. Submit under provisions of Section 01 33 00. B. Product Data: Manufacturer’s data sheets on each product to be used, including: 1.
Preparation instructions including recommendations. 2. Storage and handling requirements including recommendations.3. Provide cut sheets on each product specified showing power and mounting requirements.
1.4 QuaLity assurancE A. Manufacturer Qualifications: Providing sole source for design, engineering, manufacturing
and warranty claims handling. B. Installer Qualifications: Installation services are available upon request by a factory installer.
Any and all work varying from that as described through the installation guide will be outsourced. Installer trained by factory (preferred).
1.5 dELivEry, storagE, and HandLing A. Deliver materials and equipment to project site in manufacture’s shipping carton. B. Store products in manufacturer’s unopened packaging until ready for installation.C. Store and dispose of solvent-based materials, in accordance with requirements of local
authorities having jurisdiction.
1.6 sitE conditions A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits
recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer’s absolute limits.
1.7 coordinationA. The fan shall be capable of receiving a stop command from the fire panel, a VESDA, or any
number of smoke, flame or heat detectors. B. The fans shall be as follows:
1. The fan shall meet the air velocity requirements of FM Global’s 2.0 data sheet for ESFRsprinklers.
2. If required by the local fire prevention authority or desired by the purchaser, the fan shallbe wired into the building’s fire suppression system so that the fan will shut off as soon as a fire is detected. To facilitate this, the fan shall include a Variable Frequency Drive (VFD) within the control panel. The Fire Alarm installer must supply the low voltage wire and relay needed to accomplish this.
3. When the fan is shut off upon fire detection as described above, the fans shall come to acomplete stop with in 30 seconds
HvLs fans
manufacturEr:MacroAir Technologies Inc.794 S. Allen Street, San Bernardino, CA 92408-2210 www.macro-air.com
![Page 29: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/29.jpg)
1.8 Warranty A. Manufacturer shall repair or replace defective parts in accordance to the following list of
warranted parts: 1. Twelve year service life prorated limited warranty.2. Lifetime on airfoils, hub, and frame.
Part 2 Products2.1 aPProvEd manufacturEs
A. Acceptable Manufacturer: MacroAir Technologies Inc., which is located at: 794 S. Allen Street, San Bernardino, CA 92408-2210 Toll Free Tel: 866-668-3247; Tel: 909-890-2270; Web; www.macro-air.com
B. Substitutions: Not permitted.
2.2 macroair-HvLs cEiLingfansA. Product: AIRECO Line as manufactured by MacroAir Technologies Inc.
1. Complete Unit: The fan shall be ETL certified and built pursuant to constructionguidelines set forth by UL Standards 507, 746C, 1004, 1917 And CSA standards 22.2 No. 71, 22.2 No. 113,22.2, No. 100, 22.2 No. 156. The “ECO 6TM” p/n MA06WB3806 wall-mount fan is available in several versions: Fans with variable speed and fan guarduse p/n as shown; Fan with variable speed and NO guard-add “-NG” to the p/n; Single speed fan with guard-add “-SS” the p/n; Single speed fan with NO guard-add “-SSNG” to p/n. Note, these fans do not require guy wires for installation unless they are ceiling mounted. Single speed models cannot be run in the reverse mode. a) Performance:
1. Fan Diameter 6 feet: Max Speed Air Displacement Forward- 26,432 CFM.Reverse-20,686 CFM.
2. Efficiency at Max. Speed: 148.68 CFM/Watt3. Power Usage: .265 KW4. Max Speed: 204 RPM5. Decibel output: Less than 65dB measured 20 feet high at fan center.
b) Airfoils:1. Diameter: 6 feet (1,628 mm)2. Number of Airfoils: 6.3. Area Coverage: Up to 100 ft x 20 ft.4. Typical industrial spacing from fan center to fan center: 45 ft.5. Typical Dairy Spacing from fan center to fan center: 40 ft.6. Airfoil Material: 6036-T6 Extruded Aluminum.7. Airfoil Finish: Anodized8. Airfoil Finish: Custom powder coated colors available upon request.9. Airfoil Finish: Custom corrosion resistant, heresite colors available.10. Hardware: (2) two 5/16-24 x 2” grade 5 hex bolts.11. Hardware: (2) two 5/16”-inch flat washers.12. Hardware: (2) two 5/16”-inch nylon lock nuts.
c) Motor/Gearbox:1. Motor type: Integral2. Motor Frame Finish and Color: Powder black3. Motor Frame Finish and Color: Custom colors available.4. HP: .3755. 3 Phase6. RPM: 2047. Torque: 9.6 lbs./inch8. Ratio: 8.33/1
![Page 30: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/30.jpg)
9. Continuous operation up to 104°F10. Service Interval: F11. Gear reducer: 2-stage helical12. Gear reducer: Lubed for life.13. Shaft Diameter: 1”
d) (Optional) Motor Control Panel (MCP) and Remote Switchbox:1. Electrical Requirements: 120VAC single phase 50/60 Hz.2. Electrical Requirements: 208-240VAC single phase 50/60 Hz.3. Electrical Requirements: 208-240VAC 3 phase 60 Hz.4. Electrical Requirements: 380-415VAC 3 phase 50/60 Hz.5. Electrical Requirements: 460-480VAC 3 phase 50/60 Hz.6. Disconnect Switch Amp: 20-25 Amps, Lockable.7. Frame: D56.8. Output: .375 HP.9. Remote Control Wall Mounted Switch: NEMA 4/4x.10. Controls: Variable speed switch.11. Controls: On/off, forward and reverse.12. Optional enclosure: NEMA 4/4x.13. Consult factory for special wiring.
e) Mounting and Frame:1. Ceiling Mount: includes a 14 ½”-inch drop.2. Wall Mount.3. Pole Mount.4. Additional extensions are available, up to ten (10) feet in 1 foot increments.5. Frame: Black powder coated.6. Frame: Welded A369 Steel fabrication7. SAE Grade 5 hardware.8. Custom powder coated colors available upon request.
f) Hybrid Hub:1. Hub Material: 356 T-6 Cast Aluminum2. Blade Strut Material: 102 cold-rolled steel.3. Blade Strut Finish: Black Zinc Plated.4. Hardware: 3/8-24 x 1 3/4 “-inch Grade 5 Hex Bolts, 12x.5. Hardware: 3/8”-inch flat washer (SAE), 12x.6. Hardware: 3/8”-inch Nylon lock nut, 12x.
g) Safety System:1. Safety Cable Material: 1/4” x 7 x 19 Aircraft Stainless Steel.2. Safety Cable Finish: Galvanized.3. Guy Wire Material (Ceiling mount only): 1/8” x 7 x 10 Aircraft Stainless Steel4. Guy Wire Finish (Ceiling mount only): Galvanized.5. Safety Disk Material: Galvanized clear zinc plate.6. Safety disc Finish: Black powder coat.7. Safety disc Spacer: 3/8: inch NOM. Sch. 40, 6061-T-6 aluminum pipe.8. Safety Retaining Plate Material: Galvanized clear zinc Plate.9. Safety Retaining Plate Finish: Galvanized.10. Blade Retainer Link Material: 10 Galvanized Mild Steel.11. Blade Retainer Link Finish: Zinc.12. Rotor Retaining Ring Material: 3/16 A 569 Steel.13. Rotor Retaining Ring Finish: Zinc.14. Safety Link Extenders materials (NG models only): 10 GA A569 steel15. Safety Link Extenders finish (NG models only): Zinc plated.
![Page 31: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/31.jpg)
Part 3 EXEcution
3.1 instaLLationA. Install units per manufacturer’s written instructions.B. Fan blade height to be a minimum of 10 feet from the floor in accordance with OSHA and/or
any other governing guidelines.C. All safety and support features must be installed. These include any guy wires and safety
cables as well as blade retainer locking features.D. Adjust unit as required for proper operation in accordance with manufacturer’s installation
instructions.E. Securely anchor units.F. Ensure that operating parts work freely and fit neatly.G. Repair or replace damaged parts, dents, buckles, abrasions or other damage affecting
appearance or serviceability, as acceptable to Architect or Engineer.
3.2 PrEParationA. Check accuracy of dimensions indicated for openings to receive fans.B. Check location of utility services.C. Coordinate location and installation of the HVLS Fans.D. Ensure building structural members are sufficient to support the weight and operation of the
fan. Consult professional engineer, registered architect and building codes as required.
3.3 ProtEctionA. Protect finished Work until date of Substantial Completion.B. Touch-up, repair or replace damaged products before Substantial Completion.
3.4 cLEaning A. Clean Work per Section 01 74 00.B. Clean fans per manufacturer’s instructions.C. Remove temporary protective cover at date of Substantial Completion.
![Page 32: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/32.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
32 www.nueraheat.com
airEco/6
gEnEraLModel Number(s) MA06XL3806 ....................................... ( Variable Speed with Fan Cage ) MA06XL3806-NG ................................ ( Variable Speed with No Fan Cage }MA06XL3806-SS ................................. ( Single Speed with Fan Cage ) MA06XL3806-SSNG ............................ ( Single Speed with No Fan Cage ) Diameter ............................................. 6 FT / 1.83 Meters Blade Style .......................................... XL Number of Blades .............................. 6Nominal Horsepower ......................... 0.375 HP / 0.280 kW Hanging Weight .................................. ( +70 LBS for Cage Models )
201 lbs / 91.2 Kg Shipping Weight (Including MCP, Mounting Hardware and Screen) ........ 413 lbs / 187.3 Kg
PErformancE (at maX sPEEd)Thrust ........................................................... 10.0 lbf Displacement (fwd, blowing down) ............. 26,432 CFM / 748.5 CMS Displacement (rev, blowing up) .............. 20,686 CFM / 585.8 CMS Maximum Speed .......................................... 204 RPM Power Usage @ Max. Speed. ........................ 265 kW Efficiency @ 100% Max. Speed .................... 148.68 CFM/Watt / 4.21 CMS/Watt Maximum Effective Area ............................. 100 FT x 20 FT / 30.48 Meters x 6.10 Meters Typical Industrial Spacing .......................... 45 FT / 13.7 Meters Typical Dairy Spacing .................................. 50 FT / 15.29 Meters
mounting HardWarEStandard Wall Mount .........................................................................................Black Powder Coat / 35° Horizontal Adjustment and 45° Vertical Adjustment
motorPower ................................................................................................................... 0.375 HP / 0.280 kW Ambient Operating Temperature ........................................................................ 40C°Insulation Class .................................................................................................. F
gEarboXType ....................................................................................................................2-Stage HelicalService Interval ..................................................................................................Lubed For Life
motor controL PanEL (mcP)Standard Power and Max Amp Draw ..................................................................120V, 208-240V 1Ø (11.6A), 208-240V 3Ø (6.7A), 460-480V 3Ø (3.5A) Enclosure ............................................................................................................NEMA 1Disconnect Switch ..............................................................................................20-25 Amp, LockableRemote Control Wall Mounted Switch NEMA 4X ................................................Fwd/Off/Rev w/Speed Control Knob RF Line Filter .......................................................................................................Built In VFD VFD Motor Drive Cable ........................................................................................25 Feet / 17.6 Meters Remote Cable ......................................................................................................100 Feet / 38.5 Meters Options .................................................................................................................NEMA 4/ 4x Enclosure, 50hz Operation, Line ReactorSpecial Wiring (Variable Speed Model Only) ......................................................Thermostats, fire alarm interface, VESDA, networking etc. (Consult Factory)
LinE startEr / circuit brEakEr (ss modELs)Lockable Disconnect with load protection & On/Off ........................................Starter Button
safEty comPonEntsBlade Retainer Links (6) (NG models only), Safety Cable, Guy Wires (Ceiling mount only), Patented Inter-Locking Hub
Warranty12 YRS* on Motor, Gearbox & Control Panel.Limited Lifetime on Blades, Hub & Mounting System.
*Labor Allowance to Remove and Replace in 1st YearContact MacroAir for full Warranty Details. Specifications are subject to change.
6 ft. Cage FanModel No. MA06XL3806/NG/SS/SSNG
![Page 33: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/33.jpg)
MA
06W
B38
06-N
G/S
S/N
GSS
AIR
ECO
WA
LL-M
OU
NT
HVL
S FA
N6
FOO
T D
IAM
ETER
3/8
HP,
6 B
LAD
E
OVE
RH
EAD
VIE
W
LEFT
VIE
WFR
ON
T VI
EWR
IGH
T VI
EW
ALL
INFO
RM
ATIO
N C
ON
TAIN
ED IN
TH
IS D
RAW
ING
IS P
RO
PER
TY O
F M
ACR
OAI
R T
ECH
NO
LOG
IES,
INC
.P
ERM
ISSI
ON
IS G
RAN
TED
ON
LY F
OR
LIM
ITED
USE
IN A
RC
HIT
ECTU
RAL
/EN
GIN
EER
ING
DR
AWIN
GS.
ANY
OTH
ER D
ISTR
IBU
TIO
N R
EQU
IRES
PR
IOR
PER
MIS
SIO
N O
F M
ACR
OAI
R T
ECH
NO
LOG
IES,
INC
.C
AD D
RAW
ING
S AC
TUAL
SIZ
E (1
:1).
DO
NO
T R
ESIZ
E; R
EQU
EST
OTH
ER F
AN S
IZES
FR
OM
MAC
RO
AIR
TEC
HN
OLO
GIE
S, IN
C.
![Page 34: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/34.jpg)
The AirSpan generates a huge column of air that flows down to the ground and outward 360 degrees. The large, gently-moving air mass moves through the space effectively mixing and circulating the air to create a more pleasant environment. One 24 FT, 2-HP AirSpan fan generates 376,804 CFM (cubic feet per minute) and covers approximately 20,000 sq. ft. The cost to run this fan for eight hours is about one dollar.
airsPan
![Page 35: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/35.jpg)
41
Safe
ty S
yste
m
Mot
or F
ram
e
Gea
rbox
1.5H
P M
otor
Uni
vers
al M
ount
ing
Har
dwar
e
Hyb
rid
Hub
Str
ut
Scal
e: 1
:8
Hyb
rid
Hub
Max
Air
1.5H
P P
ower
Uni
t
DO
NO
T SC
ALE
DR
AWIN
G
MAx
xXL1
506 SH
EET
1 O
F 1
6/6/
2011
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
BC
UN
LESS
OTH
ERW
ISE
SPEC
IFIE
D:
SCAL
E: 1
:12
WEI
GH
T:
REV
DW
G.
NO
.
ASIZE
TITL
E:
Mac
roAi
r Te
chno
logi
es79
4 S
Alle
n St
. San
Ber
nard
ino,
CA
9240
8
NAM
ED
ATE
CO
MM
ENTS
:
Q.A
.
MFG
AP
PR
.
ENG
AP
PR
.
CH
ECK
ED
DR
AWN
FIN
ISH
MAT
ERIA
L
INTE
RP
RET
GEO
MET
RIC
TOLE
RAN
CIN
G P
ER:
DIM
ENSI
ON
S AR
E IN
INC
HES
TOLE
RAN
CES
:FR
ACTI
ON
AL.0
10AN
GU
LAR
: MAC
H1
BEN
D
1TW
O P
LAC
E D
ECIM
AL
.01
THR
EE P
LAC
E D
ECIM
AL
.001
APP
LIC
ATIO
N
USE
D O
NN
EXT
ASSY
PR
OP
RIE
TAR
Y AN
D C
ON
FID
ENTI
AL
54
32
1
THE
INFO
RM
ATIO
N C
ON
TAIN
ED IN
TH
IS
DR
AWIN
G IS
TH
E SO
LE P
RO
PER
TY O
F M
acro
Air
TEC
HN
OLO
GIE
S. A
NY
REP
RO
DU
CTI
ON
IN P
AR
T O
R A
S A
WH
OLE
W
ITH
OU
T TH
E W
RIT
TEN
PER
MIS
SIO
N O
F M
acro
Air
TEC
HN
OLO
GIE
S IS
PR
OH
IBIT
ED.
air
sPa
n 1
.5H
P P
ower
Uni
t
![Page 36: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/36.jpg)
42
Uni
vers
al M
ount
ing
Har
dwar
e
Scal
e: 1
:8
Max
Air
1.5H
P P
ower
Uni
t
DO
NO
T SC
ALE
DR
AWIN
G
MAx
xXL1
506 SH
EET
1 O
F 1
6/6/
2011
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
BC
UN
LESS
OTH
ERW
ISE
SPEC
IFIE
D:
SCAL
E: 1
:12
WEI
GH
T:
REV
DW
G.
NO
.
ASIZE
TITL
E:
Mac
roAi
r Te
chno
logi
es79
4 S
Alle
n St
. San
Ber
nard
ino,
CA
9240
8
NAM
ED
ATE
CO
MM
ENTS
:
Q.A
.
MFG
AP
PR
.
ENG
AP
PR
.
CH
ECK
ED
DR
AWN
FIN
ISH
MAT
ERIA
L
INTE
RP
RET
GEO
MET
RIC
TOLE
RAN
CIN
G P
ER:
DIM
ENSI
ON
S AR
E IN
INC
HES
TOLE
RAN
CES
:FR
ACTI
ON
AL.0
10AN
GU
LAR
: MAC
H1
BEN
D
1TW
O P
LAC
E D
ECIM
AL
.01
THR
EE P
LAC
E D
ECIM
AL
.001
APP
LIC
ATIO
N
USE
D O
NN
EXT
ASSY
PR
OP
RIE
TAR
Y AN
D C
ON
FID
ENTI
AL
54
32
1
THE
INFO
RM
ATIO
N C
ON
TAIN
ED IN
TH
IS
DR
AWIN
G IS
TH
E SO
LE P
RO
PER
TY O
F M
acro
Air
TEC
HN
OLO
GIE
S. A
NY
REP
RO
DU
CTI
ON
IN P
AR
T O
R A
S A
WH
OLE
W
ITH
OU
T TH
E W
RIT
TEN
PER
MIS
SIO
N O
F M
acro
Air
TEC
HN
OLO
GIE
S IS
PR
OH
IBIT
ED.
Gea
rmot
or
Mot
or F
ram
e
Safe
ty S
yste
m
Hyb
rid
Hub
Str
ut
Hyb
rid
Hub
air
sPa
n 2
HP
Pow
er U
nit
![Page 37: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/37.jpg)
37
© 2012 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
Part 1 gEnEraL 1.1 summary
A. The mounted High Volume Low Speed (HVLS) fans shall be MacroAir Fans. The fan model shall be of the AIRSPAN line.
1.2 rEfErEncEs A. American National Standards Institute/Air Movement and Control Association (ANSI/AMCA)
Standard 230-07 - Laboratory Methods of Testing Air Circulating Fans for Rating.
1.3 submittaLs A. Submit under provisions of Section 01 33 00.B. Product Data: Manufacturer’s data sheets on each product to be used, including:
1. Preparation instructions including recommendations.2. Storage and handling requirements including recommendations.3. Provide cut sheets on each product specified showing power and mounting requirements.
1.4 QuaLity assurancE A. Manufacturer Qualifications: Providing sole source for design, engineering, manufacturing
and warranty claims handling.B. Installer Qualifications: Installation services are available upon request by a factory installer.
Any and all work varying from that as described through the installation guide will be outsourced. Installer trained by factory (preferred).
1.5 dELivEry, storagE, and HandLing A. Deliver materials and equipment to project site in manufacture’s shipping carton.B. Store products in manufacturer’s unopened packaging until ready for installation.
1.6 sitE conditions A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits
recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer’s absolute limits.
1.7 coordinationA. The fan shall be capable of receiving a stop command from the fire panel, a VESDA, or any
number of smoke, flame or heat detectors.B. The fans shall be as follows:
1. The fan shall meet the air velocity requirements of FM Global’s 2.0 data sheet for ESFRsprinklers.
2. If required by the local fire prevention authority or desired by the purchaser, the fan shallbe wired into the building’s fire suppression system so that the fan will shut off as soon as a fire is detected. To facilitate this, the fan shall include a Variable Frequency Drive (VFD) within the control panel. The low voltage wire and relay needed to accomplish this must be supplied by the Fire Alarm installer.
3. When the fan is shut off, upon fire detection as described above, the fans shall come to acomplete stop in less than 30 seconds.
HvLs fans
manufacturEr:MacroAir Technologies Inc.794 S. Allen Street, San Bernardino, CA 92408-2210 www.macro-air.com
![Page 38: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/38.jpg)
1.8 Warranty A. Manufacturer shall repair or replace defective parts in accordance to the following list of
warranted parts: 1. Twelve year service life prorated limited warranty.2. Lifetime on airfoils, hub, and frame.
Part 2 Products2.1 aPProvEd manufacturEs
A. Acceptable Manufacturer: MacroAir Technologies Inc., which is located at: 794 S. Allen Street, San Bernardino, CA 92408-2210 Toll Free Tel: 866-668-3247; Tel: 909-890-2270; Web; www.macro-air.com
B. Substitutions: Not permitted.
2.2 macroair-HvLs cEiLingfansA. Product: AIRSPAN HVLS Fan as manufactured by MacroAir Technologies Inc.
1. Complete Unit: The fan shall be ETL certified and built pursuant to construction guidelinesset forth by UL Standards 507, 746C,1004, 1917 And CSA standards 22.2 No. 71, 22.2 No. 113,22.2, No. 100, 22.2 No. 156. The fan shall include a Variable Frequency Drive (VFD) system specifically programmed for HVLS fans in order to ensure limited sound levels. a) Performance: All fans tested to ANSI/AMCA standard 230-07:
1. Fan Diameter 24 feet: Max Speed Air Displacement Forward 376,804 CFM.Reverse-263,763 CFM.a) Efficiency at Max Speed: 310.13 CFM/Watt.
2. Fan Diameter 20 feet: Max Speed Air Displacement Forward- 237,231 CFM.Reverse-166,062 CFM.a) Efficiency at Max Speed: 306.51 CFM/Watt.
3. Decibel output: Less than 65dB measured 20 feet high at fan center.b) Airfoils:
1. Diameter: 20 feet (6096mm).2. Diameter: 24 feet (7320mm)3. Number of Airfoils: 6.4. Area Coverage: Up to 20,000 sq. ft (185 sq. m); 110 feet (33.5 m) from the fan’s center.5. Airfoil Material: 6036-T6 Extruded Aluminum.6. Airfoil Finish: Anodized7. Airfoil Finish: Custom powder coated colors available upon request.8. Airfoil Finish: Custom corrosion resistant, heresite colors available.9. Hardware: (2) two 5/16-24 x 2” grade 5 hex bolts.10. Hardware: (2) two 5/16”-inch flat washers.11. Hardware: (2) two 5/16”-inch nylon lock nuts.
c) Motor:1. HP: 1.5 or 22. 3 Phase.3. RPM: 17504. Continuous operation up to 104°F5. Service Interval: F6. Motor Frame Finish and Color: Powder coat teal.7. Motor Frame Finish and Color: Custom colors available
d) Motor Control Panel (MCP) and Remote Switchbox:1. Electrical Requirements: 208-240VAC three (3) phase 60 Hz.2. Electrical Requirements: 380-415VAC 3 phase 50/60 Hz.3. Electrical Requirements: 460-480VAC 3 phase 50/60 Hz.4. Full Load Amp draw: 3.25-3.10/1.55 A
![Page 39: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/39.jpg)
5. Frame: D56.6. Output: 1.5Hp or 2Hp.7. Disconnect Switch Amp: 20-25 Amps, Lockable.8. Remote Control Wall Mounted Switch: NEMA 4/4x.9. Controls: Variable speed switch.10. Controls: On/off, forward and reverse.11. Optional enclosure: NEMA 4/4x.12. Consult factory for special wiring.
e) Gear Reducer:1. 2-Stage Helical.2. Lubed for life.3. Shaft Diameter: 1.250”
f) Mounting and Frame:1. Standard Mount: Universal I-beam clamp with swivel joint and a 7.5”-inch drop.2. (Optional): Glulam Mount: Brackets with a swivel joint and a 7.5”-inch drop.3. (Optional) Extra wide/ thick I-beam Mount.4. Mounting to building structural support other than glulam; i.e. angle iron (back to
back), or uni-strut.5. Additional extensions available, up to ten (10) feet in one (1) foot increments.6. Frame: Black powder coated.7. Frame: Welded A369 Steel fabrication.8. SAE Grade 5 hardware.
g) Hybrid Hub:1. Hub Material: 356 T-6 Cast Aluminum.2. Blade Strut Material: 6061 T-6 Aluminum.3. Blade Strut Finish: Black Anodized.4. Hardware: 3/8-24 x 1 3/4:”-inch Grade 5 Hex Bolts, 12x.5. Hardware: 3/8”-inch flat washer (SAE), 12x.6. Hardware: 3/8”-inch nylon lock nut, 12x.
h) Safety System:1. Safety Cable Material: 1/4” x 7 x 19 Aircraft Stainless Steel.2. Safety Cable Finish: Galvanized.3. Guy Wire Material: 1/8” x 7 x 10 Aircraft Stainless Steel.4. Guy Wire Finish: Galvanized.5. Safety Disk Material: Galvanized clear zinc plate.6. Safety disc Finish: Black Powder coat.7. Safety disc Spacer: 3/8”: inch NOM. Sch. 40, 6061-T-6 aluminum pipe.8. Safety Retaining Plate Material: Galvanized clear zinc plate.9. Safety Retaining Plate Finish: Galvanized.10. Blade Retainer Link Material: 10 Galvanized Mild Steel.11. Blade Retainer Link Finish: Zinc.
Part 3 EXEcution 3.1 instaLLation
A. Install units per manufacturer’s written instructions.B. Fan blade height to be a minimum of 10 feet from the floor in accordance with OSHA and/or
any other governing guidelines.C. All safety and support features must be installed. These include any guy wires and safety
cables as well as blade retainer locking features.D. Adjust unit as required for proper operation in accordance with manufacturer’s installation
instructions.E. Securely anchor units.
![Page 40: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/40.jpg)
F. Ensure that operating parts work freely and fit neatly.G. Repair or replace damaged parts, dents, buckles, abrasions or other damage affecting
appearance or serviceability, as acceptable to Architect or Engineer.
3.2 PrEParationA. Check accuracy of dimensions indicated for openings to receive fans.B. Check location of utility services.C. Coordinate location and installation of the HVLS Fans.D. Ensure building structural members are sufficient to support the weight and operation of the
fan. Consult professional engineer or registered architect and building codes as required.
3.3 ProtEctionA. Protect finished Work until date of Substantial Completion.B. Touch-up, repair or replace damaged products before Substantial Completion.
3.4 cLEaning A. Clean Work per Section 01 74 00.B. Clean fans per manufacturer’s instructions.C. Remove temporary protective cover at date of Substantial Completion.
![Page 41: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/41.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
41 www.nueraheat.com
airsPan/20
gEnEraLModel Number ........................................................... MA20XL1506Diameter ................................................................... 20 FT / 6.07 Meters Blade Style ................................................................ XLNumber of Blades .................................................... 6Nominal Horsepower ............................................... 1.5 HP / 1.125 kW Hanging Weight (average) ........................................ 217 lbs / 98.4 Kg Shipping Weight (Including MCP, Mounting Hardware) (average) ................................388 lbs / 175.9 Kg Power Unit Pallet Dimensions / Weight 26” X 30” X 33.5” / 246 lbs / 0.66 X 0.76X 0.85 Meters / 111.58 KgBlade Pallet Dimensions/Weight 120” X 25” X 15” / 152 lbs / 3.0 X .63 X .38 Meters / 69.1 Kg
PErformancE (at maX sPEEd)Thrust .......................................................... 81.0 lbf Displacement (fwd, blowing down) ............. 237,231 CFM / 6717.6 CMS Displacement (rev, blowing up) ................... 166,062 CFM / 4702.4 CMS Maximum Speed ........................................... 70 RPM Power Usage @ Max. Speed. ........................ 1.032 kW Efficiency @ 100% Max. Speed .................... 306.51 CFM/Watt / 9.28 CMS/Watt Maximum Effective Area ............................. 18,000 SQ FT 1673.3 m2 Typical Industrial Spacing ........................... 100 FT / 30.48 Meters Maximum dB ................................................ 61*
mounting HardWarEStandard Mount .................................................................................................Universal I-Beam Clamp w/ Swivel Joint and a 7.5” Drop Glulam Mount (Optional) ..................................................................................Brackets w/ Swivel Joint & 7.5” Drop Extra Wide / Thick I-Beam Mount (Optional) ..................................................Upon RequestAdditional Drop Extensions (Optional) .............................................................Up to 10 FT in 1 FT Increments
motorPower ...................................................................................................................1.5 HP / 1.125 kW Ambient Operating Temperature ........................................................................56C° Insulation Class ...................................................................................................FService Factor .....................................................................................................1.25
gEarboXType .....................................................................................................................2-Stage HelicalService Interval ..................................................................................................Lubed For Life
motor controL PanEL (mcP)Standard Power and Max Amp Draw ..................................................................120V, 208-240V 1Ø (11.6A), 208-240V 3Ø (6.7A), 460-480V 3Ø (3.5A)Enclosure ............................................................................................................NEMA 1Disconnect Switch ..............................................................................................20-25 Amp, LockableRemote Control Wall Mounted Switch NEMA 4X ................................................Fwd/Off/Rev w/Speed Control Knob RF Line Filter .......................................................................................................Built In VFD VFD Motor Drive Cable ........................................................................................25 Feet / 7.62 MetersRemote Cable ......................................................................................................100 Feet / 30.48 MetersOptions .................................................................................................................NEMA 4/ 4x Enclosure, 50hz Operation, Line ReactorSpecial Wiring (Variable Speed Model Only) ......................................................Thermostats, fire alarm interface, VESDA, networking etc. (Consult Factory)
safEty comPonEntsBlade Retainer Links (6), Safety Cable, Guy Wires (Ceiling mount only), Patented Inter-Locking Hub
Warranty12 YRS* on Motor, Gearbox & Control Panel.Limited Lifetime on Blades, Hub & Mounting System.
*dB Values Were Obtained by Testing. Specific Applications/Installation values may vary.*Labor Allowance to Remove and Replace in 1st YearContact MacroAir for full Warranty Details. Specifications are subject to change.
20 ft. 1.5HP Fan Model No. MA20XL1506
![Page 42: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/42.jpg)
50
20' A
IRSP
AN
DO
NO
T SC
ALE
DR
AWIN
G
MA2
0XL1
506 SH
EET
1 O
F 1
6/6/
2011
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
BC
UN
LESS
OTH
ERW
ISE
SPEC
IFIE
D:
SCAL
E: 1
:60
WEI
GH
T:
REV
DW
G.
NO
.
ASIZE
TITL
E:
Mac
roAi
r Te
chno
logi
es79
4 S
Alle
n St
. San
Ber
nard
ino,
CA
9240
8
NAM
ED
ATE
CO
MM
ENTS
:
Q.A
.
MFG
AP
PR
.
ENG
AP
PR
.
CH
ECK
ED
DR
AWN
FIN
ISH
MAT
ERIA
L
INTE
RP
RET
GEO
MET
RIC
TOLE
RAN
CIN
G P
ER:
DIM
ENSI
ON
S AR
E IN
INC
HES
TOLE
RAN
CES
:FR
ACTI
ON
AL.0
10AN
GU
LAR
: MAC
H1
BEN
D
1TW
O P
LAC
E D
ECIM
AL
.01
THR
EE P
LAC
E D
ECIM
AL
.001
APP
LIC
ATIO
N
USE
D O
NN
EXT
ASSY
PR
OP
RIE
TAR
Y AN
D C
ON
FID
ENTI
AL
THE
INFO
RM
ATIO
N C
ON
TAIN
ED IN
TH
ISD
RAW
ING
IS T
HE
SOLE
PR
OP
ERTY
OF
Mac
roAi
r TE
CH
NO
LOG
IES.
AN
Y R
EPR
OD
UC
TIO
N IN
PAR
T O
R A
S A
WH
OLE
WIT
HO
UT
THE
WR
ITTE
N P
ERM
ISSI
ON
OF
Mac
roAi
r TE
CH
NO
LOG
IES
IS
PR
OH
IBIT
ED.
54
32
1
3'
2'-4
"
20'
![Page 43: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/43.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
43 www.nueraheat.com
airsPan/24
gEnEraLModel Number ........................................................... MA24XL2006 Diameter ................................................................... 24 FT / 7.32 Meters Blade Style ................................................................ XLNumber of Blades .................................................... 6Nominal Horsepower ............................................... 2.0 HP / 1.5 kW Hanging Weight (average) ........................................ 236 lbs / 107.0 Kg Shipping Weight (Including MCP, Mounting Hardware) (average) ................................427 lbs / 197.8 Kg Power Unit Pallet Dimensions / Weight 26” X 30” X 33.5” / 246 lbs / 0.66 X 0.76X 0.85 Meters / 111.58 Kg Blade Pallet Dimensions/Weight 144” X 25” X 15” / 191 lbs / 3.6 X .63 X .38 Meters / 86.8 Kg
PErformancE (at maX sPEEd)Thrust .......................................................... 102 lbf Displacement (fwd, blowing down) ............. 376,804 CFM / 10669.9 CMS Displacement (rev, blowing up) ................... 263,763 CFM / 7468.9 CMS Maximum Speed ........................................... 65 RPM Power Usage @ Max. Speed. ........................ 1.65 kW Efficiency @ 100% Max. Speed .................... 309.81 CFM/Watt / 8.79 CMS/Watt Maximum Effective Area ............................. 20,000 SQ FT / 1858.1 m2 Typical Industrial Spacing ........................... 110 FT / 33.52 Meters Maximum dB ................................................ 61*
mounting HardWarEStandard Mount .................................................................................................Universal I-Beam Clamp w/ Swivel Joint and a 7.5” Drop Glulam Mount (Optional) ..................................................................................Brackets w/ Swivel Joint & 7.5” Drop Extra Wide / Thick I-Beam Mount (Optional) ..................................................Upon RequestAdditional Drop Extensions (Optional) .............................................................Up to 10 FT in 1 FT Increments
motorPower ...................................................................................................................2 HP / 1.5 kW Ambient Operating Temperature ........................................................................40C° Insulation Class ...................................................................................................FService Factor .....................................................................................................1.15
gEarboXType .....................................................................................................................2-Stage HelicalService Interval ..................................................................................................Lubed For Life
motor controL PanEL (mcP)Standard Power and Max Amp Draw ..................................................................208-240V 1Ø (11.6A), 208-240V 3Ø (6.7A), 460-480V 3Ø (3.5A)Enclosure ............................................................................................................NEMA 1Disconnect Switch ..............................................................................................20-25 Amp, LockableRemote Control Wall Mounted Switch NEMA 4X ................................................Fwd/Off/Rev w/Speed Control Knob RF Line Filter .......................................................................................................Built In VFD VFD Motor Drive Cable ........................................................................................25 Feet / 7.62 MetersRemote Cable ......................................................................................................100 Feet / 30.48 MetersOptions .................................................................................................................NEMA 4/ 4x Enclosure, 50hz Operation, Line ReactorSpecial Wiring (Variable Speed Model Only) ......................................................Thermostats, fire alarm interface, VESDA, networking etc. (Consult Factory)
safEty comPonEntsBlade Retainer Links (6), Safety Cable, Guy Wires (Ceiling mount only), Patented Inter-Locking Hub
Warranty12 YRS* on Motor, Gearbox & Control Panel.Limited Lifetime on Blades, Hub & Mounting System.
*dB Values Were Obtained by Testing. Specific Applications/Installation values may vary.*Labor Allowance to Remove and Replace in 1st YearContact MacroAir for full Warranty Details. Specifications are subject to change.
24 ft. 2HP Fan Model No. MA24XL2006
![Page 44: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/44.jpg)
52
24' A
IRSP
AN
DO
NO
T SC
ALE
DR
AWIN
G
MA2
4XL2
006 SH
EET
1 O
F 1
6/6/
2011
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
BC
UN
LESS
OTH
ERW
ISE
SPEC
IFIE
D:
SCAL
E: 1
:75
WEI
GH
T:
REV
DW
G.
NO
.
ASIZE
TITL
E:
Mac
roAi
r Te
chno
logi
es79
4 S
Alle
n St
. San
Ber
nard
ino,
CA
9240
8
NAM
ED
ATE
CO
MM
ENTS
:
Q.A
.
MFG
AP
PR
.
ENG
AP
PR
.
CH
ECK
ED
DR
AWN
FIN
ISH
MAT
ERIA
L
INTE
RP
RET
GEO
MET
RIC
TOLE
RAN
CIN
G P
ER:
DIM
ENSI
ON
S AR
E IN
INC
HES
TOLE
RAN
CES
:FR
ACTI
ON
AL.0
10AN
GU
LAR
: MAC
H1
BEN
D
1TW
O P
LAC
E D
ECIM
AL
.01
THR
EE P
LAC
E D
ECIM
AL
.001
APP
LIC
ATIO
N
USE
D O
NN
EXT
ASSY
PR
OP
RIE
TAR
Y AN
D C
ON
FID
ENTI
AL
THE
INFO
RM
ATIO
N C
ON
TAIN
ED IN
TH
ISD
RAW
ING
IS T
HE
SOLE
PR
OP
ERTY
OF
Mac
roAi
r TE
CH
NO
LOG
IES.
AN
Y R
EPR
OD
UC
TIO
N IN
PAR
T O
R A
S A
WH
OLE
WIT
HO
UT
THE
WR
ITTE
N P
ERM
ISSI
ON
OF
Mac
roAi
r TE
CH
NO
LOG
IES
IS
PR
OH
IBIT
ED.
54
32
1
3'
2'-4
"
20'
![Page 45: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/45.jpg)
The AirSol’s air movement system includes the HVLS fan with an attached controller, a specialized component that converts power from the solar panels, standard remote control and an optional auxiliary power supply. When used in conjunction with the auxiliary power supply, the AirSol fan can be used when sunlight is not available to power the system – ensuring you always have a power source available to run the system.
airsoL
![Page 46: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/46.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
46 www.nueraheat.com
airsoL/16
gEnEraLModel Number ........................................................... MA16V0506Diameter ................................................................... 16 FT / 4.88 Meters Blade Style ................................................................ XL Number of Blades .................................................... 6Nominal Horsepower ............................................... 0.33 HP / 0.25 kW Hanging Weight ......................................................... 150 lbs / 68.0 Kg Shipping Weight (Including MCP, Mounting Hardware) (average) ................................315 lbs / 142.9 Kg Power Unit Pallet Dimensions / Weight 26” X 30” X 33.5” / 150 lbs / 0.64 X 0.76 X 0.85 Meters / 68.0 Kg Blade Pallet Dimensions/Weight 96” X 25” X 15” / 139 lbs / 2.4 X .63 X .38 Meters / 63.0 Kg SolarPanel Pallet Dimensions 57” x 43” x 12” / 175 lbs / 1.4 x 1.1 x 0.3 Meters / 79.4 Kg
soLar PanELs ( 3 ) Power ........................................................... 3 x 180 Watts Dimensions ................................................... 39” x 53” x 1.5”
PErformancE (at maX sPEEd)Thrust .......................................................... 21.4 lbfDisplacement (fwd, blowing down) ............. 115,332 CFM / 3265.8 CMS Maximum Speed ........................................... 53 RPM Maximum Effective Area ............................. 8,000 SQ FT / 743.2 m2 Typical Industrial Spacing ........................... 65 FT / 19.81 Meters
mounting HardWarEStandard Mount .................................................................................................Universal I-Beam Clamp w/ Swivel Joint and a 12” Drop Glulam Mount (Optional) ..................................................................................Brackets w/ Swivel Joint & 12” Drop Extra Wide / Thick I-Beam Mount (Optional) ..................................................Upon RequestAdditional Drop Extensions (Optional) .............................................................Up to 10 FT in 1 FT Increments
motor / controLLEr Remote Control Wall Mounted Switch NEMA 4X ...............................................Fwd/Off/Rev w/Speed Control Knob Power ...................................................................................................................0.33 HP / 0.25 kW Volts .....................................................................................................................DC 15—30v Insulation Class ...................................................................................................F Maximum Current ...............................................................................................25 Amps
gEarboXType .....................................................................................................................2-Stage HelicalService Interval ..................................................................................................Lubed For Life
oPtions Power Supply ......................................................................................................Plug in Power Supply and Auxiliary Backup
WarrantyMotor, Gearbox & Control Panel .......................................................................12 YRS.* Blades, Hub & Mounting System ......................................................................Limited Lifetime
safEty comPonEntsBlade Retainer Links (6), Safety Cable, Guy Wires (Ceiling mount only), Patented Inter-Locking Hub
Warranty12 YRS* on Motor, Gearbox & Control Panel.Limited Lifetime on Blades, Hub & Mounting System.
*Labor Allowance to Remove and Replace in 1st YearContact MacroAir for full Warranty Details. Specifications are subject to change.
16 ft. Solar Fan Model No. MA16V0506
![Page 47: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/47.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
47 www.nueraheat.com
airsoL/18
gEnEraLModel Number ........................................................... MA18V0506Diameter ................................................................... 18 FT / 5.49 Meters Blade Style ................................................................ XL Number of Blades .................................................... 6Nominal Horsepower ............................................... 0.33 HP / 0.25 kW Hanging Weight ......................................................... 185 lbs / 83.9 Kg Shipping Weight (Including MCP, Mounting Hardware) (average) ................................350 lbs / 158.8 Kg Power Unit Pallet Dimensions / Weight 26” X 30” X 33.5” / 150 lbs / 0.64 X 0.76 X 0.85 Meters / 68.0 Kg Blade Pallet Dimensions/Weight 108” X 25” X 15” / 146 lbs / 3.0 X .74 X .46 Meters / 66.2 Kg Solar Panel Pallet Dimensions 57” x 43” x 12” / 175 lbs / 1.4 x 1.1 x 0.3 Meters / 79.4 Kg
soLar PanELs ( 3 ) Power ........................................................... 3 x 180 Watts Dimensions ................................................... 39” x 53” x 1.5”
PErformancE (at maX sPEEd)Thrust .......................................................... 23.0 lbf Displacement (fwd, blowing down) ............. 134,451 CFM / 3807.2 CMS Maximum Speed ........................................... 53 RPM Maximum Effective Area ............................. 8,000 SQ FT / 743.2 m2 Typical Industrial Spacing ........................... 65 FT / 19.81 Meters
mounting HardWarEStandard Mount .................................................................................................Universal I-Beam Clamp w/ Swivel Joint and a 12” Drop Glulam Mount (Optional) ..................................................................................Brackets w/ Swivel Joint & 12” Drop Extra Wide / Thick I-Beam Mount (Optional) ..................................................Upon RequestAdditional Drop Extensions (Optional) .............................................................Up to 10 FT in 1 FT Increments
motor / controLLEr Remote Control Wall Mounted Switch NEMA 4X ...............................................Fwd/Off/Rev w/Speed Control Knob Power ...................................................................................................................0.33 HP / 0.25 kW Volts .....................................................................................................................DC 15—30v Insulation Class ...................................................................................................F Maximum Current ...............................................................................................25 Amps
gEarboXType .....................................................................................................................2-Stage HelicalService Interval ..................................................................................................Lubed For Life
oPtions Power Supply ......................................................................................................Plug in Power Supply and Auxiliary Backup
WarrantyMotor, Gearbox & Control Panel .......................................................................12 YRS.* Blades, Hub & Mounting System ......................................................................Limited Lifetime
safEty comPonEntsBlade Retainer Links (6), Safety Cable, Guy Wires (Ceiling mount only), Patented Inter-Locking Hub
Warranty12 YRS* on Motor, Gearbox & Control Panel.Limited Lifetime on Blades, Hub & Mounting System.
*Labor Allowance to Remove and Replace in 1st YearContact MacroAir for full Warranty Details. Specifications are subject to change.
18 ft. Solar Fan Model No. MA18V0506
![Page 48: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/48.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
48 www.nueraheat.com
airsoL/20
gEnEraLModel Number ........................................................... MA20V0506Diameter ................................................................... 20 FT / 6.07 Meters Blade Style ................................................................ XL Number of Blades .................................................... 6Nominal Horsepower ............................................... 0.33 HP / 0.25 kW Hanging Weight ......................................................... 185 lbs / 83.9 Kg Shipping Weight (Including MCP, Mounting Hardware) (average) ................................350 lbs / 158.8 Kg Power Unit Pallet Dimensions / Weight 26” X 30” X 33.5” / 150 lbs / 0.64 X 0.76 X 0.85 Meters / 68.0 Kg Blade Pallet Dimensions/Weight 120” X 25” X 15” / 152 lbs / 3.0 X .63 X .38 Meters / 69.1 Kg Solar Panel Pallet Dimensions 57” x 43” x 12” / 175 lbs / 1.4 x 1.1 x 0.3 Meters / 79.4 Kg
soLar PanELs ( 3 ) Power ........................................................... 3 x 180 Watts Dimensions ................................................... 39” x 53” x 1.5”
PErformancE (at maX sPEEd)Thrust .......................................................... 23.5 lbf Displacement (fwd, blowing down) ............. 151,030 CFM / 4276.7 CMS Maximum Speed ........................................... 53 RPM Maximum Effective Area ............................. 8,000 SQ FT / 743.2 m2 Typical Industrial Spacing ........................... 65 FT / 19.81 Meters
mounting HardWarEStandard Mount .................................................................................................Universal I-Beam Clamp w/ Swivel Joint and a 12” Drop Glulam Mount (Optional) ..................................................................................Brackets w/ Swivel Joint & 12” Drop Extra Wide / Thick I-Beam Mount (Optional) ..................................................Upon RequestAdditional Drop Extensions (Optional) .............................................................Up to 10 FT in 1 FT Increments
motor / controLLEr Remote Control Wall Mounted Switch NEMA 4X ...............................................Fwd/Off/Rev w/Speed Control Knob Power ...................................................................................................................0.33 HP / 0.25 kW Volts .....................................................................................................................DC 15—30v Insulation Class ...................................................................................................F Maximum Current ...............................................................................................25 Amps
gEarboXType .....................................................................................................................2-Stage HelicalService Interval ..................................................................................................Lubed For Life
oPtions Power Supply ......................................................................................................Plug in Power Supply and Auxiliary Backup
WarrantyMotor, Gearbox & Control Panel .......................................................................12 YRS.* Blades, Hub & Mounting System ......................................................................Limited Lifetime
safEty comPonEntsBlade Retainer Links (6), Safety Cable, Guy Wires (Ceiling mount only), Patented Inter-Locking Hub
Warranty12 YRS* on Motor, Gearbox & Control Panel.Limited Lifetime on Blades, Hub & Mounting System.
*Labor Allowance to Remove and Replace in 1st YearContact MacroAir for full Warranty Details. Specifications are subject to change.
20 ft. Solar Fan Model No. MA20V0506
![Page 49: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/49.jpg)
Brand new technology at MacroAir has given us the AirStar Series. This new product is lightweight, sleek, easy to install, ultra-quiet, and more efficient than other HVLS fans on the market. Powered by 120 Volts (standard household current)*, there is no application that this fan can’t handle.
* Only applies to AirStar 8,10,12.
airstar Commercial
![Page 50: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/50.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
50 www.nueraheat.com
Part 1 gEnEraL 1.1 summary
A. The mounted High Volume Low Speed (HVLS) fans shall be MacroAir Fans. The fan model shall be of the AIRSTAR.
1.2 rEfErEncEs A. American National Standards Institute/Air Movement and Control Association (ANSI/AMCA)
Standard 230-07 - Laboratory Methods of Testing Air Circulating Fans for Rating.
1.3 submittaLs A. Submit under provisions of Section 01 33 00.B. Product Data: Manufacturer’s data sheets on each product to be used, including:
1. Preparation instructions including recommendations.2. Storage and handling requirements including recommendations.3. Provide cut sheets on each product specified showing power and mounting requirements.
1.4 QuaLity assurancE A. Manufacturer Qualifications: Providing sole source for design, engineering, manufacturing
and warranty claims handling.B. Installer Qualifications: Installation services are available upon request by a factory installer.
Any and all work varying from that as described through the installation guide will be outsourced. Installer trained by factory (preferred).
1.5 dELivEry, storagE, and HandLing A. Deliver materials and equipment to project site in manufacture’s shipping carton.B. Store products in manufacturer’s unopened packaging until ready for installation.C. Store and dispose of solvent-based materials, in accordance with requirements of local
authorities having jurisdiction.
1.6 sitE conditions A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits
recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer’s absolute limits.
1.7 coordinationA. The fan shall be capable of receiving a stop command from the fire panel, a VESDA, or any
number of smoke, flame or heat detectors.B. The fans shall be as follows:
1. The fan shall meet the air velocity requirements of FM Global’s 2.0 data sheet for ESFRsprinklers.
2. If required by the local fire prevention authority or desired by the purchaser, the fan shallbe wired into the building’s fire suppression system so that the fan will shut off as soon as a fire is detected. To facilitate this, the fan shall include a Variable Frequency Drive (VFD) within the control panel. The low voltage wire and relay needed to accomplish this must be supplied by the Fire Alarm installer.
3. When the fan is shut off, upon fire detection as described above, the fans shall come to acomplete stop in less than 30 seconds.
HvLs fans
manufacturEr:MacroAir Technologies Inc.794 S. Allen Street, San Bernardino, CA 92408-2210 www.macro-air.com
![Page 51: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/51.jpg)
1.8 Warranty A. Manufacturer shall repair or replace defective parts in accordance to the following list of
warranted parts: 1. Twelve year service life prorated limited warranty.2. Lifetime on airfoils, hub, and frame.
Part 2 Products2.1 aPProvEd manufacturEs
A. Acceptable Manufacturer: MacroAir Technologies Inc., which is located at: 794 S. Allen Street, San Bernardino, CA 92408-2210 Toll Free Tel: 866-668-3247; Tel: 909-890-2270; Web; www.macro-air.com
B. Substitutions: Not permitted.
2.2 macroair-HvLs cEiLingfansA. Product: AIRSTAR HVLS Fan as manufactured by MacroAir Technologies Inc.
1. Complete Unit: The fan shall be ETL certified and built pursuant to construction guidelinesset forth by UL Standards 507, 746C,1004, 1917 And CSA standards 22.2 No. 71, 22.2 No. 113,22.2, No. 100, 22.2 No. 156. The fan shall include a Variable Frequency Drive (VFD) system specifically programmed for HVLS fans in order to ensure limited sound levels.a) Performance: All fans tested to ANSI/AMCA standard 230-07:
1. Fan Diameter 20 feet: Full Power Air Displacement Forward- 151,030 CFM.a) Efficiency at Max. Speed: 442.90 CFM/Watt/ 12.54 CMS/Watt
2. Fan Diameter 18 feet: Full Power Air Displacement Forward- 134,451 CFMa) Efficiency at Max. Speed: 340.38 CFM/Watt/ 9.64 CMS/Watt
3. Fan diameter 16 feet: Full Power Air Displacement Forward- 115,332 CFM,a) Efficiency at Max. Speed: 304.31 CFM/Watt/ 8.62 CMS/Watt
4. Decibel output: Less than 65dB measured 20 feet high at fan center.b) Airfoils:
1. Diameter: 16 feet (4880mm).2. Diameter: 18 feet (5490mm).3. Diameter: 20 feet (6096mm).4. Number of Airfoil: 6.5. Area Coverage: Up to 8,000 sq. ft (743.22 sq. m); 65 feet (19.812 m) from the fan’s
center in all directions.6. Airfoil Material: 6036-T6 Extruded Aluminum.7. Airfoil Finish: Anodized8. Airfoil Finish: Custom powder coated colors available upon request.9. Airfoil Finish: Custom corrosion resistant, heresite colors available.10. Airfoil End Caps: Cast Aluminum11. Hardware: (2) two 5/16-24 x 2” grade 5 hex bolts.12. Hardware: (2) two 5/16”-inch flat washers.13. Hardware: (2) two 5/16”-inch nylon lock nuts.
c) Motor:1. Motor Frame Finish and Color: Powder coat grey.2. Motor Frame Finish and Color: Custom colors available.3. Electrical Requirements: 120VAC single phase 50/60 Hz.4. Electrical Requirements: 208-240VAC three (3) phase 60 Hz.5. Electrical Requirements: 380-415VAC 3 phase 50/60 Hz.6. Electrical Requirements: 460-480VAC 3 phase 50/60 Hz.7. Output: 0.375 HP.
d) Motor Control Panel (MCP):1. Electrical Requirements: 208-240VAC three (3) phase 60 Hz
![Page 52: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/52.jpg)
2. Electrical Requirements: 380-415VAC three (3) phase 50/60 Hz.3. Electrical Requirements: 460-480VAC three (3) phase 50/60 Hz4. Full load Amps: 3.25-3.10/1.55 Amps5. Disconnect Switch Amp: 20-25 Amps, Lockable.6. Frame: D567. Optional enclosure: NEMA 4/4x8. Line Starter/Circuit Breaker: Lockable Disconnect with load protection and on/off
starter button.9. Consult factory for special wiring.
e) Gear Reducer:1. 2-Stage Helical.2. Lubed for life.3. Shaft Diameter: 1”
f) Mounting and Frame:1. Standard Mount: Universal I-beam clamp with swivel joint and a 7.5”-inch drop.2. (Optional): Glulam Mount: Brackets with a swivel joint and a 7.5”-inch drop.3. (Optional) Extra wide/ thick I-beam Mount.4. Mounting to building structural support other than glulam; i.e. angle iron (back to
back), or uni-strut.5. Additional extensions available, in one (1) to ten (10) foot increments.6. Frame: Black powder coated.7. Frame: Welded A369 Steel fabrication8. SAE Grade 5 hardware.
g) Hybrid Hub:1. Hub Material: 356 T-6 Cast Aluminum2. Blade Strut Material: 6061 T-6 Aluminum3. Blade Strut Finish: Black Anodized.4. Hardware: 3/8-24 x 1 ¾” -inch Grade 5 Hex Bolts, 12x.5. Hardware: 3/8”-inch flat washer (SAE), 12x.6. Hardware: 3/8”-inch nylon lock nut, 12x.
h) Safety System:1. Safety Cable Material: 1/4” x 7 x 19 Aircraft Stainless Steel.2. Safety Cable Finish: Galvanized.3. Guy Wire Material: 1/8” x 7 x 10 Aircraft Stainless Steel4. Guy Wire Finish: Galvanized.5. Safety Disk Material: Galvanized clear zinc plate.6. Safety disc Finish: Black Powder coat.7. Safety disc Spacer: 3/8”: inch NOM. Sch. 40, 6061-T-6 aluminum pipe.8. Safety Retaining Plate Material: Galvanized clear zinc plate.9. Safety Retaining Plate Finish: Galvanized.10. Blade Retainer Link Material: 10 Galvanized Mild Steel.11. Blade Retainer Link Finish: Zinc.
Part 3 EXEcution 3.1 instaLLation
A. Install units per manufacturer’s written instructions.B. Fan blade height to be a minimum of 10 feet from the floor in accordance with
OSHA guidelines.C. All safety and support features must be installed. These include any guy wires and safety
cables as well as blade retainer locking features.D. Adjust unit as required for proper operation in accordance with manufacturer’s
installation instructions.
![Page 53: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/53.jpg)
E. Securely anchor units.F. Ensure that operating parts work freely and fit neatly.G. Repair or replace damaged parts, dents, buckles, abrasions or other damage affecting
appearance or serviceability, as acceptable to Architect.
3.2 PrEParationA. Check accuracy of dimensions indicated for openings to receive fans.B. Check location of utility services.C. Coordinate location and installation of the HVLS Fans.D. Ensure building structural members are sufficient to support the weight and operation of the
fan. Consult professional engineer or registered architect as required.
3.3 ProtEctionA. Protect finished Work until date of Substantial Completion.B. Touch-up, repair or replace damaged products before Substantial Completion.
3.4 cLEaning A. Clean Work per Section 01 74 00.B. Clean fans per manufacturer’s instructions.C. Remove temporary protective cover at date of Substantial Completion.
![Page 54: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/54.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
54 www.nueraheat.com
airstar/16
gEnEraLModel Number ........................................................... MA16XL0506Diameter ................................................................... 16 FT / 4.88 Meters Blade Style ................................................................ XLNumber of Blades .................................................... 6Nominal Horsepower ............................................... 0.375 HP / 0.280 kW Hanging Weight ......................................................... 150 lbs / 68.0 Kg Shipping Weight (Including MCP, Mounting Hardware) (average) ................................315 lbs / 142.9 Kg Power Unit Pallet Dimensions / Weight 26” X 30” X 33.5” / 150 lbs / 0.64 X 0.76 X 0.85 Meters / 68.0 Kg Blade Pallet Dimensions/Weight 96” X 25” X 15” / 139 lbs / 2.4 X .63 X .38 Meters / 63.0 Kg
PErformancE (at maX sPEEd)Thrust .......................................................... 21.4 lbf Displacement (fwd, blowing down) ............. 115,332 CFM / 3265.8 CMS Maximum Speed ........................................... 53 RPM Power Usage @ Max. Speed. ........................ 0.379 kW Efficiency @ 100% Max. Speed .................... 304.31 CFM/Watt / 8.62 CMS/Watt Maximum Effective Area ............................. 8,000 SQ FT / 743.2 m2 Typical Industrial Spacing ........................... 65 FT / 19.81 Meters
mounting HardWarEStandard Mount .................................................................................................Black Powder Coat / 35° Horizontal Adjustment and 45° Vertical Adjustment
motorPower ...................................................................................................................0.375 HP / 0.280 kW Ambient Operating Temperature ........................................................................25C° Insulation Class ...................................................................................................F
gEarboXType .....................................................................................................................2-Stage HelicalService Interval ..................................................................................................Lubed For Life
motor controL PanEL (mcP)Standard Power and Max Amp Draw ..................................................................120V, 208-240V 1Ø (11.6A), 208-240V 3Ø (6.7A), 460-480V 3Ø (3.5A) Enclosure ............................................................................................................NEMA 1Disconnect Switch ..............................................................................................20-25 Amp, LockableRemote Control Wall Mounted Switch NEMA 4X ................................................Fwd/Off/Rev w/Speed Control Knob RF Line Filter .......................................................................................................Built In VFD VFD Motor Drive Cable ........................................................................................25 Feet / 17.6 Meters Remote Cable ......................................................................................................100 Feet / 38.5 Meters Options .................................................................................................................NEMA 4/ 4x Enclosure, 50hz Operation, Line Reactor Special Wiring (Variable Speed Model Only) ......................................................Thermostats, fire alarm interface, VESDA, networking etc. (Consult Factory)
LinE startEr / circuit brEakEr (ss modELs) Lockable Disconnect with load protection & On/Off ........................................Starter Button )
safEty comPonEntsBlade Retainer Links (6), Safety Cable, Guy Wires (Ceiling mount only), Patented Inter-Locking Hub
Warranty12 YRS* on Motor, Gearbox & Control Panel.Limited Lifetime on Blades, Hub & Mounting System.
*Labor Allowance to Remove and Replace in 1st YearContact MacroAir for full Warranty Details. Specifications are subject to change.
16 ft. Commercial Fan Model No. MA16XL0506
![Page 55: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/55.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
55 www.nueraheat.com
MA
16W
0506
AIR
STA
R H
VLS
FAN
18 F
OO
T D
IAM
ETER
0.37
5 H
P, 6
BLA
DE
OVE
RH
EAD
VIE
W
LEFT
VIE
WFR
ON
T VI
EWR
IGH
T VI
EW
ALL
INFO
RM
ATIO
N C
ON
TAIN
ED IN
TH
IS D
RAW
ING
IS P
RO
PER
TY O
F M
ACR
OAI
R T
ECH
NO
LOG
IES,
INC
.P
ERM
ISSI
ON
IS G
RAN
TED
ON
LY F
OR
LIM
ITED
USE
IN A
RC
HIT
ECTU
RAL
/EN
GIN
EER
ING
DR
AWIN
GS.
ANY
OTH
ER D
ISTR
IBU
TIO
N R
EQU
IRES
PR
IOR
PER
MIS
SIO
N O
F M
ACR
OAI
R T
ECH
NO
LOG
IES,
INC
.C
AD D
RAW
ING
S AC
TUAL
SIZ
E (1
:1).
DO
NO
T R
ESIZ
E; R
EQU
EST
OTH
ER F
AN S
IZES
FR
OM
MAC
RO
AIR
TEC
HN
OLO
GIE
S, IN
C.
![Page 56: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/56.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
56 www.nueraheat.com
airstar/18
gEnEraLModel Number ........................................................... MA18XL0506Diameter ................................................................... 18 FT / 5.49 Meters Blade Style ................................................................ XLNumber of Blades .................................................... 6Nominal Horsepower ............................................... 0.375 HP / 0.280 kW Hanging Weight ......................................................... 185 lbs / 83.9 Kg Shipping Weight (Including MCP, Mounting Hardware) (average) ................................350 lbs / 158.8 Kg Power Unit Pallet Dimensions / Weight 26” X 30” X 33.5” / 246 lbs / 0.66 X 0.76X 0.85 Meters / 111.58 KgBlade Pallet Dimensions/Weight108” X 25” X 15” / 146 lbs 2.7 X .63 X .38 Meters / 66.4 Kg
PErformancE (at maX sPEEd)Thrust .......................................................... 23.0 lbf Displacement (fwd, blowing down) ............. 134,451 CFM / 3807.2 CMS Maximum Speed ........................................... 53 RPM Power Usage @ Max. Speed. ........................ 0.395 kW Efficiency @ 100% Max. Speed .................... 340.38 CFM/Watt / 9.64 CMS/Watt Maximum Effective Area ............................. 8,000 SQ FT / 743.2 mTypical Industrial Spacing ........................... 65 FT / 19.81 Meters
mounting HardWarEStandard Mount .................................................................................................Black Powder Coat / 35° Horizontal Adjustment and 45° Vertical Adjustment
motorPower ...................................................................................................................0.375 HP / 0.280 kW Ambient Operating Temperature ........................................................................25C° Insulation Class ...................................................................................................F
gEarboXType .....................................................................................................................2-Stage HelicalService Interval ..................................................................................................Lubed For Life
motor controL PanEL (mcP)Standard Power and Max Amp Draw ..................................................................120V, 208-240V 1Ø (11.6A), 208-240V 3Ø (6.7A), 460-480V 3Ø (3.5A) Enclosure ............................................................................................................NEMA 1Disconnect Switch ..............................................................................................20-25 Amp, LockableRemote Control Wall Mounted Switch NEMA 4X ................................................Fwd/Off/Rev w/Speed Control Knob RF Line Filter .......................................................................................................Built In VFD VFD Motor Drive Cable ........................................................................................25 Feet / 17.6 Meters Remote Cable ......................................................................................................100 Feet / 38.5 Meters Options .................................................................................................................NEMA 4/ 4x Enclosure, 50hz Operation, Line Reactor Special Wiring (Variable Speed Model Only) ......................................................Thermostats, fire alarm interface, VESDA, networking etc. (Consult Factory)
LinE startEr / circuit brEakEr (ss modELs) Lockable Disconnect with load protection & On/Off ........................................Starter Button )
safEty comPonEntsBlade Retainer Links (6), Safety Cable, Guy Wires (Ceiling mount only), Patented Inter-Locking Hub
Warranty12 YRS* on Motor, Gearbox & Control Panel.Limited Lifetime on Blades, Hub & Mounting System.
*Labor Allowance to Remove and Replace in 1st YearContact MacroAir for full Warranty Details. Specifications are subject to change.
18 ft. Commercial Fan Model No. MA18XL0506
![Page 57: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/57.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
57 www.nueraheat.com
MA
18W
0506
AIR
STA
R H
VLS
FAN
18 F
OO
T D
IAM
ETER
0.37
5 H
P, 6
BLA
DE
OVE
RH
EAD
VIE
W
LEFT
VIE
WFR
ON
T VI
EWR
IGH
T VI
EW
ALL
INFO
RM
ATIO
N C
ON
TAIN
ED IN
TH
IS D
RAW
ING
IS P
RO
PER
TY O
F M
ACR
OAI
R T
ECH
NO
LOG
IES,
INC
.P
ERM
ISSI
ON
IS G
RAN
TED
ON
LY F
OR
LIM
ITED
USE
IN A
RC
HIT
ECTU
RAL
/EN
GIN
EER
ING
DR
AWIN
GS.
ANY
OTH
ER D
ISTR
IBU
TIO
N R
EQU
IRES
PR
IOR
PER
MIS
SIO
N O
F M
ACR
OAI
R T
ECH
NO
LOG
IES,
INC
.C
AD D
RAW
ING
S AC
TUAL
SIZ
E (1
:1).
DO
NO
T R
ESIZ
E; R
EQU
EST
OTH
ER F
AN S
IZES
FR
OM
MAC
RO
AIR
TEC
HN
OLO
GIE
S, IN
C.
![Page 58: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/58.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
58 www.nueraheat.com
airstar/20
gEnEraLModel Number ........................................................... MA20S0506 Diameter ................................................................... 20 FT / 6.07 Meters Blade Style ................................................................ XLNumber of Blades .................................................... 6Nominal Horsepower ............................................... 0.375 HP / 0.280 kW Hanging Weight ......................................................... 185 lbs / 83.9 Kg Shipping Weight (Including MCP, Mounting Hardware) (average) ................................350 lbs / 158.8 Kg g Power Unit Pallet Dimensions / Weight 26” X 30” X 33.5” / 246 lbs / 0.66 X 0.76X 0.85 Meters / 111.58 Kg Blade Pallet Dimensions/Weight120” X 25” X 15” / 152 lbs / 3.0 X .63 X .38 Meters / 69.1 Kg
PErformancE (at maX sPEEd)Thrust .......................................................... 23.5 lbf Displacement (fwd, blowing down) ............. 151,030 CFM / 4276.7 CMS Maximum Speed ........................................... 53 RPM Power Usage @ Max. Speed. ........................ 0.341 kW Efficiency @ 100% Max. Speed .................... 442.90 CFM/Watt / 12.54 CMS/Watt Maximum Effective Area ............................. 8,000 SQ FT / 743.2 m2
Typical Industrial Spacing ........................... 65 FT / 19.81 Meters
mounting HardWarEStandard Mount .................................................................................................Black Powder Coat / 35° Horizontal Adjustment and 45° Vertical Adjustment
motorPower ...................................................................................................................0.375 HP / 0.280 kW Ambient Operating Temperature ........................................................................25C° Insulation Class ...................................................................................................F
gEarboXType .....................................................................................................................2-Stage HelicalService Interval ..................................................................................................Lubed For Life
motor controL PanEL (mcP)Standard Power and Max Amp Draw ..................................................................120V, 208-240V 1Ø (11.6A), 208-240V 3Ø (6.7A), 460-480V 3Ø (3.5A) Enclosure ............................................................................................................NEMA 1Disconnect Switch ..............................................................................................20-25 Amp, LockableRemote Control Wall Mounted Switch NEMA 4X ................................................Fwd/Off/Rev w/Speed Control Knob RF Line Filter .......................................................................................................Built In VFD VFD Motor Drive Cable ........................................................................................25 Feet / 17.6 Meters Remote Cable ......................................................................................................100 Feet / 38.5 Meters Options .................................................................................................................NEMA 4/ 4x Enclosure, 50hz Operation, Line Reactor Special Wiring (Variable Speed Model Only) ......................................................Thermostats, fire alarm interface, VESDA, networking etc. (Consult Factory)
LinE startEr / circuit brEakEr (ss modELs) Lockable Disconnect with load protection & On/Off ........................................Starter Button )
safEty comPonEntsBlade Retainer Links (6), Safety Cable, Guy Wires (Ceiling mount only), Patented Inter-Locking Hub
Warranty12 YRS* on Motor, Gearbox & Control Panel.Limited Lifetime on Blades, Hub & Mounting System.
*Labor Allowance to Remove and Replace in 1st YearContact MacroAir for full Warranty Details. Specifications are subject to change.
20 ft. Commercial Fan Model No. MA20S0506
![Page 59: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/59.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
59 www.nueraheat.com
MA
20S0
506
AIR
STA
R H
VLS
FAN
20 F
OO
T D
IAM
ETER
0.37
5 H
P, 6
BLA
DE
OVE
RH
EAD
VIE
W
LEFT
VIE
WFR
ON
T VI
EWR
IGH
T VI
EW
ALL
INFO
RM
ATIO
N C
ON
TAIN
ED IN
TH
IS D
RAW
ING
IS P
RO
PER
TY O
F M
ACR
OAI
R T
ECH
NO
LOG
IES,
INC
.P
ERM
ISSI
ON
IS G
RAN
TED
ON
LY F
OR
LIM
ITED
USE
IN A
RC
HIT
ECTU
RAL
/EN
GIN
EER
ING
DR
AWIN
GS.
ANY
OTH
ER D
ISTR
IBU
TIO
N R
EQU
IRES
PR
IOR
PER
MIS
SIO
N O
F M
ACR
OAI
R T
ECH
NO
LOG
IES,
INC
.C
AD D
RAW
ING
S AC
TUAL
SIZ
E (1
:1).
DO
NO
T R
ESIZ
E; R
EQU
EST
OTH
ER F
AN S
IZES
FR
OM
MAC
RO
AIR
TEC
HN
OLO
GIE
S, IN
C.
![Page 60: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/60.jpg)
A sleek aluminum drive housing and extruded aluminum aerospace blades make the AirStar a beautiful addition to any room or space. But the real beauty of AirStar is the energy savings. Since one AirStar fan replaces up to six conventional ceiling fans, the difference in energy consumption is dramatic. *Powered by 120 Volts (standard household current), there is no application that this fan can’t handle.
* Only applies to AirStar 8,10,12.
airstar
![Page 61: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/61.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
61 www.nueraheat.com
airstar/8 8 ft. Fan Model No. MA08XL1606
gEnEraLModel Number ........................................................... MA08XL1606Diameter ................................................................... 8 Ft Blade Style ................................................................ XLNumber of Blades .................................................... 6Nominal Horsepower ............................................... 0.167 HP Hanging Weight ......................................................... 90 lbs
PErformancE (at maX sPEEd) Maximum Speed ........................................... 130 RPM Torque Transmitted @ max speed. ............... 6 Ft/lb Performance @ max speed ......................... 32032 CFMSound level @ max speed ............................ <40 dBCurrent draw @ max Speed ......................... 2 Amps
EfficiEncy @ maX sPEEdInput Power .........................................................................................................100-120/50-60V/Hz Maximum In Rush Current Rating ......................................................................6 ampsMaximum Effective Area .....................................................................................1024 SQ Ft Typical Spacing ....................................................................................................32 Ft
motorPower ...................................................................................................................0.167 HP Ambient Operating Temperature ........................................................................40C° Insulation Class ...................................................................................................F
oPtionsMount Option .......................................................................................................Adjustable Rigid Mount (45 degrees) Mount Option ......................................................................................................Beam Clamp Kit (up to 12”)Mount Option ......................................................................................................Glulam Kit (up to 12”)
![Page 62: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/62.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
62 www.nueraheat.com
airstar/10 10 ft. Fan Model No. MA10XL1606
gEnEraLModel Number ........................................................... MA10XL1606Diameter ................................................................... 10 Ft Blade Style ................................................................ XLNumber of Blades .................................................... 6Nominal Horsepower ............................................... 0.167 HP Hanging Weight ......................................................... 100 lbs
PErformancE (at maX sPEEd) Maximum Speed ........................................... 95 RPM Torque Transmitted @ max speed. ............... 6 Ft/lb Performance @ max speed ......................... 40040 CFMSound level @ max speed ............................ <40 dBCurrent draw @ max Speed ......................... 2 Amps
EfficiEncy @ maX sPEEdInput Power .........................................................................................................100-120/50-60V/Hz Maximum In Rush Current Rating ......................................................................6 amps Maximum Effective Area .....................................................................................1600 SQ.FtTypical Spacing ...................................................................................................40 Ft
motorPower ...................................................................................................................0.167 HPAmbient Operating Temperature ........................................................................40C° Insulation Class ...................................................................................................F
oPtionsMount Option .......................................................................................................Adjustable Rigid Mount (45 degrees) Mount Option ......................................................................................................Beam Clamp Kit (up to 12”)Mount Option ......................................................................................................Glulam Kit (up to 12”)
![Page 63: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/63.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
63 www.nueraheat.com
airstar/12 12 ft. Fan Model No. MA12XL1606
gEnEraLModel Number ........................................................... MA12XL1606Diameter ................................................................... 12 Ft Blade Style ................................................................ XLNumber of Blades .................................................... 6Nominal Horsepower ............................................... 0.167 HP Hanging Weight ......................................................... 110 lbs
PErformancE (at maX sPEEd) Maximum Speed ........................................... 60 RPM Torque Transmitted @ max speed. ............... 6 Ft/lb Performance @ max speed ......................... 45300 CFMSound level @ max speed ............................ <40 dBCurrent draw @ max Speed ......................... 2 Amps
EfficiEncy @ maX sPEEdInput Power .........................................................................................................100-120/50-60V/Hz Maximum In Rush Current Rating ......................................................................6 amps Maximum Effective Area .....................................................................................2300 SQ.FtTypical Spacing ...................................................................................................48 Ft
motorPower ...................................................................................................................0.167 HPAmbient Operating Temperature ........................................................................40C° Insulation Class ...................................................................................................F
oPtionsMount Option .......................................................................................................Adjustable Rigid Mount (45 degrees) Mount Option ......................................................................................................Beam Clamp Kit (up to 12”)Mount Option ......................................................................................................Glulam Kit (up to 12”)
![Page 64: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/64.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
64 www.nueraheat.com
Sample LayoutsManufacturing Facility
MA
16XL1006
MA
24XL1006M
A24XL1006
![Page 65: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/65.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
65 www.nueraheat.com
Sample LayoutsBarn - Equestrian
MA
16XL2006
Bottom
Section
Top Section
MA
24XL2006M
A16XL2006
MA
16XL2006
Side View
80'80'
![Page 66: EnginEEring and dEsign guidE - NuEra Heat Specs/NuEra-MacroAir... · 2015. 2. 13. · 24-ft, 2.0 HP AirSpan (MA24XL2006) ... be supplied by the Fire Alarm installer. 3. When the fan](https://reader035.fdocuments.us/reader035/viewer/2022071501/611fbee3e16df6355b7b55aa/html5/thumbnails/66.jpg)
© 2012 MacroAir Technologies Toll Free: 800-347-9575
66 www.nueraheat.com
RSAP12RSBG129RSBG129
92
1G
BS
R
92
1G
BS
R
RSAP12
RSAP12RSAP12 RSP03
RSBG129 RSBG069
21
PA
SR
21
PA
SR
21
PA
SR
21
PA
SR
96
0G
BS
RRL
CB
OA
RLC
BO
ARL
CB
RR
CB
OA
RR
CB
OA
RR
CB
21
PA
SR
21
PA
SR
96
0G
BS
R9
01
GB
SR
09
SR
09
SR
FA
SR
FA
SR
21
PA
SR
21
PA
SR
21
PA
SR
RSAP16 RSAP12 RSAP12
RSAP10
RSAP10
01
PA
SR
96
0G
BS
R
RSP03
21
PA
SR
RSBG129
RSAP16
RSAP10
90
1G
BS
R9
60
GB
SR
21
PA
SR
30
PS
R
RSAP12
RSAP12
RSAP12
RSAP
102
1P
AS
R
21
PS
R2
1P
SR
21
PS
R
92
1G
BS
R9
21
GB
SR
92
1G
BS
R9
21
GB
SR
92
1G
BS
R
21
PS
R2
1P
SR
21
PS
R2
1P
SR
21
PS
R
RSP10RSP10
RSP10RSP10
RSP10RSP10
RSP10RSP10
RSP10RSP10
RSP10RSP10
RSP10
RSP10
RSP10
RSP10
RSP10
RSP10
RSP10
RSP10
RG
AS
R
RG
AS
R
RG
AS
R
RG
AS
R
RG
AS
R
RG
AS
R
RG
AS
R
RG
AS
R
RG
AS
R
RG
AS
R
21T
WS
R
90
1G
BS
R
RG
AS
R
97
0G
BS
R
97
0G
BS
RRS
AP10
RSAP10
RSAP12
RSP10
21
PS
R
RSP10
RSP10
21
PS
R
RSP10
RSP10
21
PS
R
RSP10
21
PS
R
RSP10 RSP10
92
1G
BS
R
RSP03
S04
RSAP10
RSAP12
RSAP10RSAP10
RSAP12
RSAP12
RSAP12
RSAP12
RSAP10
RSAP10
RSAP12
RSAP12
RSAP12
RSAP
10RSAP10
RSAP12RSAP12RSAP10RSAP10
RSAP10
98
0G
BS
R
RSAP12
RSAP14
RSAP10
RSAP06RSBG08
9
RSAP12
RSAP12
RSAP10
RSAP14
21
PA
SR
92
1G
BS
R9
21
GB
SR
92
1G
BS
R9
21
GB
SR
92
1G
BS
R9
21
GB
SR
92
1G
BS
R
21T
WS
R
YGL
XO
BR
YG
RX
OB
R
89
CR
89
SC
R
RSAP10
RSAP10
RSAP10RSAP12
PCG12
SCEF
FA
WP
P
325'
110'
24' M
axA
ir24
' Max
Air
24' M
axA
ir
110'
Sample LayoutsRiding Arena - Equestrian