Worldwide Standards Overview
Why is important to know and understand local efficiency regulations?
Understand OEMs and end customers needs;
Be a technical reference about efficiency regulations and get
customer’s trustworthy by giving correct support;
Avoid non compliance efficiency level on the end of the sales process;
Find the optimal point between stock volume and motor flexibility;
Be aware and ready to react during shifting of efficiency levels having
the right motors in stock and avoiding stock of outdated motors.
![Page 3: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz](https://reader034.fdocuments.us/reader034/viewer/2022042119/5e989ab157aa784b281fa093/html5/thumbnails/3.jpg)
Main Standards Worldwide
NEMA IEC ABNT AS/NZS
![Page 4: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz](https://reader034.fdocuments.us/reader034/viewer/2022042119/5e989ab157aa784b281fa093/html5/thumbnails/4.jpg)
Frequency Worldwide
50Hz
60Hz
![Page 5: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz](https://reader034.fdocuments.us/reader034/viewer/2022042119/5e989ab157aa784b281fa093/html5/thumbnails/5.jpg)
E2
High Premium
E1
Green Rate / Efficiency Regulations
IEC
NEMA
AS/NZS
ABNT
China
IE4
Standard
IE3IE2IE1
E3+E3
Grade 2Grade 3
Super Prem.
Alto Rend.Padrão
Grade 1
Alto R. Plus
![Page 6: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz](https://reader034.fdocuments.us/reader034/viewer/2022042119/5e989ab157aa784b281fa093/html5/thumbnails/6.jpg)
Minimum Efficiency - IEC
IE3
IE2
IE1
Europe since Jan 2015 (7.5 to 375kW)
and shifting in 2017 (0.75 to 5.5kW)
China now follow
IE2 efficiency
values (GR3=IE2)
![Page 7: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz](https://reader034.fdocuments.us/reader034/viewer/2022042119/5e989ab157aa784b281fa093/html5/thumbnails/7.jpg)
Premium
High
Std
ME market is basically
IEC, but NEMA is
required for some
projects (oil & gas)
Minimum Efficiency - NEMA
Mandatory at North America
![Page 8: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz](https://reader034.fdocuments.us/reader034/viewer/2022042119/5e989ab157aa784b281fa093/html5/thumbnails/8.jpg)
Alto Rend.
Minimum Efficiency - ABNT
Mandatory
60Hz countries in Latin
America also accept
ABNT motors
![Page 9: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz](https://reader034.fdocuments.us/reader034/viewer/2022042119/5e989ab157aa784b281fa093/html5/thumbnails/9.jpg)
E3
E2
Minimum Efficiency - AS/NZS
Mandatory
Market buys E3
![Page 10: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz](https://reader034.fdocuments.us/reader034/viewer/2022042119/5e989ab157aa784b281fa093/html5/thumbnails/10.jpg)
Labeling Europe Union
IE3 Efficiency Level (7.5 up to 375kW)
Applicable to:
Motors 2, 4 and 6 poles
Ratings from 0.75 to 375kW
Frequency: 50, 60 and 50/60Hz
Voltage up to 1000V
Not applicable to:
2 speed motors
Integral brake motor
Torque Design D
Dedicated VFD design (not suitable for DOL / up to 2012)
TEAO
Intermittent duty
Ambient temperature out of the range -30 to 60oC
Altitude higher than 4000masl
Hazardous area
Synchronous motors
Nameplate shall record :
Efficiency level (IE2/IE3)
Efficiency values for 50, 75 and 100% load
CE mark
Requirements
In 2017 Europe
shifts 0.75 to
5.5kW to IE3
![Page 11: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz](https://reader034.fdocuments.us/reader034/viewer/2022042119/5e989ab157aa784b281fa093/html5/thumbnails/11.jpg)
Labeling North America
NEMA Premium Efficiency
Applicable to:
Motors 2, 4 and 6 poles
Ratings from 1 to 200HP
Voltage 230 and 460V (EUA & Mexico)
Voltages up to 600V (Canada)
Not applicable to*:
Dedicated VFD design (not suitable for DOL)
Motors higher than 200HP
Non standard voltages (excluding 230/460V)
Submersible motors (IP68)
Special shaft motors (non T frame) – US only
2 speed motors
Integral brake motor
Torque Design D
TENV and TEAO
Intermittent duty* All exceptions must meet High Efficiency Level, the only exception for High
Efficiency are the double speed motors.
Requirements
NEMA PREMIUM
required since
december 2010
Efficiency level shall be as per NEMA MG1 NEMA Premium
Efficiency level shall be printed on motor nameplate
Motor shall be registered at Department of Energy (DOE)
DOE register number shall be printed on nameplate
(WEG: CC029A)
![Page 12: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz](https://reader034.fdocuments.us/reader034/viewer/2022042119/5e989ab157aa784b281fa093/html5/thumbnails/12.jpg)
Labeling China
Motors without this label
will not be allowed through
Chinese customs!
GR3 Efficiency Level (GB 18613-2012) *
Applicable to:
Safe and Hazardous Area
Ratings from 0.75 to 375kW**
Motors 2, 4 and 6 poles
Frequency: 50Hz
Voltage up to 690V / 3ph
Torque design N
Not applicable to:
TENV and TEAO
Increased safety (Exe)
Dedicated VFD design (not suitable for DOL)
Dedicated marine and mining motors
Integrated design with driven machine
Brake motors
* Efficiency values are the same of IEC, GR3 → IE2, GR2
→ IE3, GR1 → IE4
GB 18613-2012
Requirement Label
![Page 13: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz](https://reader034.fdocuments.us/reader034/viewer/2022042119/5e989ab157aa784b281fa093/html5/thumbnails/13.jpg)
Labeling Australia & New Zealand
E2 Efficiency Level
Applicable to:
Motors 2, 4, 6 and 8 poles
Ratings from 0.73 to 185kW
Frequency: 50Hz
Up to 1100V
Not applicable to:
2 speed motors
Dedicated VFD design (not suitable for DOL)
Intermittent duty short duty cycles
Integrated design with driven machine
(TEAO not included)
Submersible motors (IP68)
Australia is evaluating a revision at
AS/NZS to follow IEC efficiency
program (to be similar).
It’s not agreed yet!
Market buys E3
Efficiency level shall be E2 or E3 as per AS/NZS 1359.55
Efficiency level shall be printed on motor nameplate
Motor design shall be registered at following link:
http://reg.energyrating.gov.au/comparator/product_types/
Requirements
![Page 14: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz](https://reader034.fdocuments.us/reader034/viewer/2022042119/5e989ab157aa784b281fa093/html5/thumbnails/14.jpg)
Labeling Brazil
Alto Rendimento / Portaria 553
Applicable to:
Closed and open enclosures
Motors 2, 4 poles up to 250cv(HP)
Motors 6 poles up to 200cv(HP)
Motors 8 poles up to 180cv(HP)
Frequency: 60Hz (or 50Hz operating in 60Hz)
Voltage up to 1000V
Duty cycle S1 or S3 (ED higher or equal to 80%)
Starting torque as per design N, H, NY or HY (or NEMA equivalent)
Not applicable to:
Integral brake motor
Dedicated VFD design (not suitable for DOL)
Intermittent duty
Explosion proof (Exd)
Increased safety (Exe)
Motors without this
label will not be
allowed through
Brazilian customs!
Procedure for non approved motors:
Check if motor efficiency is meeting ABNT requirements
Ask for an import license from Inmetro prior start export process
Dispatch the motors after receive the authorization from Inmetro
Submit sample motors to the lab for testing (Cepel, IEE/USP, Labelo)
Laboratory will issue a test certificate stating motor performance
After evlauate the test certificate Inmetro releases motors license
More information at www.inmetro.gov.br (Portaria 488)
European electrical design is not
registered on Inmetro!
Required Label
![Page 15: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz](https://reader034.fdocuments.us/reader034/viewer/2022042119/5e989ab157aa784b281fa093/html5/thumbnails/15.jpg)
Required Label
Labeling South Korea
MEPS South Korea (KEMCO) *
Applicable to:
Closed and open enclosures
Motors 2, 4, 6 and 8 poles
Ratings from 0.75 to 200kW
Voltage up to 600V
Frequency: 60Hz
Not applicable to:
TEAO and TENV
Smoke Extraction
Marine and 2 speed motors
Motors with sleeve or thrust bearings
Motors without this label will
not be allowed through
Korean customs!
Not Certified
Hazardous area motors
* Motors Exclusively manufactured at WNT
![Page 16: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz](https://reader034.fdocuments.us/reader034/viewer/2022042119/5e989ab157aa784b281fa093/html5/thumbnails/16.jpg)
Labeling Middle East
Efficiency Level
Most of Middle East countries
do not have a minimum
efficiency requirement.
Cyprus, Israel and Turkey are
the exceptions, adopting the
same requirement as Europe
(IEC IE2).
Saudi Arabia is studying also
adopting IEC IE2.
Although IEC is generally
adopted, for some specific
projects NEMA efficiency
levels may be required.
Nameplate shall record :
Efficiency level (IE2/IE3)
Efficiency values for 50, 75 and 100% load
CE mark
Requirements (only for Cyprus, Israel and Turkey)
![Page 17: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz](https://reader034.fdocuments.us/reader034/viewer/2022042119/5e989ab157aa784b281fa093/html5/thumbnails/17.jpg)