Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors...

17
Energy Efficiency Programs Worldwide Rev: 08 01/2015

Transcript of Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors...

Page 1: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz

Energy Efficiency Programs Worldwide

Rev: 08 – 01/2015

Page 2: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz

Worldwide Standards Overview

Why is important to know and understand local efficiency regulations?

Understand OEMs and end customers needs;

Be a technical reference about efficiency regulations and get

customer’s trustworthy by giving correct support;

Avoid non compliance efficiency level on the end of the sales process;

Find the optimal point between stock volume and motor flexibility;

Be aware and ready to react during shifting of efficiency levels having

the right motors in stock and avoiding stock of outdated motors.

Page 3: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz

Main Standards Worldwide

NEMA IEC ABNT AS/NZS

Page 4: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz

Frequency Worldwide

50Hz

60Hz

Page 5: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz

E2

High Premium

E1

Green Rate / Efficiency Regulations

IEC

NEMA

AS/NZS

ABNT

China

IE4

Standard

IE3IE2IE1

E3+E3

Grade 2Grade 3

Super Prem.

Alto Rend.Padrão

Grade 1

Alto R. Plus

Page 6: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz

Minimum Efficiency - IEC

IE3

IE2

IE1

Europe since Jan 2015 (7.5 to 375kW)

and shifting in 2017 (0.75 to 5.5kW)

China now follow

IE2 efficiency

values (GR3=IE2)

Page 7: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz

Premium

High

Std

ME market is basically

IEC, but NEMA is

required for some

projects (oil & gas)

Minimum Efficiency - NEMA

Mandatory at North America

Page 8: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz

Alto Rend.

Minimum Efficiency - ABNT

Mandatory

60Hz countries in Latin

America also accept

ABNT motors

Page 9: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz

E3

E2

Minimum Efficiency - AS/NZS

Mandatory

Market buys E3

Page 10: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz

Labeling Europe Union

IE3 Efficiency Level (7.5 up to 375kW)

Applicable to:

Motors 2, 4 and 6 poles

Ratings from 0.75 to 375kW

Frequency: 50, 60 and 50/60Hz

Voltage up to 1000V

Not applicable to:

2 speed motors

Integral brake motor

Torque Design D

Dedicated VFD design (not suitable for DOL / up to 2012)

TEAO

Intermittent duty

Ambient temperature out of the range -30 to 60oC

Altitude higher than 4000masl

Hazardous area

Synchronous motors

Nameplate shall record :

Efficiency level (IE2/IE3)

Efficiency values for 50, 75 and 100% load

CE mark

Requirements

In 2017 Europe

shifts 0.75 to

5.5kW to IE3

Page 11: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz

Labeling North America

NEMA Premium Efficiency

Applicable to:

Motors 2, 4 and 6 poles

Ratings from 1 to 200HP

Voltage 230 and 460V (EUA & Mexico)

Voltages up to 600V (Canada)

Not applicable to*:

Dedicated VFD design (not suitable for DOL)

Motors higher than 200HP

Non standard voltages (excluding 230/460V)

Submersible motors (IP68)

Special shaft motors (non T frame) – US only

2 speed motors

Integral brake motor

Torque Design D

TENV and TEAO

Intermittent duty* All exceptions must meet High Efficiency Level, the only exception for High

Efficiency are the double speed motors.

Requirements

NEMA PREMIUM

required since

december 2010

Efficiency level shall be as per NEMA MG1 NEMA Premium

Efficiency level shall be printed on motor nameplate

Motor shall be registered at Department of Energy (DOE)

DOE register number shall be printed on nameplate

(WEG: CC029A)

Page 12: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz

Labeling China

Motors without this label

will not be allowed through

Chinese customs!

GR3 Efficiency Level (GB 18613-2012) *

Applicable to:

Safe and Hazardous Area

Ratings from 0.75 to 375kW**

Motors 2, 4 and 6 poles

Frequency: 50Hz

Voltage up to 690V / 3ph

Torque design N

Not applicable to:

TENV and TEAO

Increased safety (Exe)

Dedicated VFD design (not suitable for DOL)

Dedicated marine and mining motors

Integrated design with driven machine

Brake motors

* Efficiency values are the same of IEC, GR3 → IE2, GR2

→ IE3, GR1 → IE4

GB 18613-2012

Requirement Label

Page 13: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz

Labeling Australia & New Zealand

E2 Efficiency Level

Applicable to:

Motors 2, 4, 6 and 8 poles

Ratings from 0.73 to 185kW

Frequency: 50Hz

Up to 1100V

Not applicable to:

2 speed motors

Dedicated VFD design (not suitable for DOL)

Intermittent duty short duty cycles

Integrated design with driven machine

(TEAO not included)

Submersible motors (IP68)

Australia is evaluating a revision at

AS/NZS to follow IEC efficiency

program (to be similar).

It’s not agreed yet!

Market buys E3

Efficiency level shall be E2 or E3 as per AS/NZS 1359.55

Efficiency level shall be printed on motor nameplate

Motor design shall be registered at following link:

http://reg.energyrating.gov.au/comparator/product_types/

Requirements

Page 14: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz

Labeling Brazil

Alto Rendimento / Portaria 553

Applicable to:

Closed and open enclosures

Motors 2, 4 poles up to 250cv(HP)

Motors 6 poles up to 200cv(HP)

Motors 8 poles up to 180cv(HP)

Frequency: 60Hz (or 50Hz operating in 60Hz)

Voltage up to 1000V

Duty cycle S1 or S3 (ED higher or equal to 80%)

Starting torque as per design N, H, NY or HY (or NEMA equivalent)

Not applicable to:

Integral brake motor

Dedicated VFD design (not suitable for DOL)

Intermittent duty

Explosion proof (Exd)

Increased safety (Exe)

Motors without this

label will not be

allowed through

Brazilian customs!

Procedure for non approved motors:

Check if motor efficiency is meeting ABNT requirements

Ask for an import license from Inmetro prior start export process

Dispatch the motors after receive the authorization from Inmetro

Submit sample motors to the lab for testing (Cepel, IEE/USP, Labelo)

Laboratory will issue a test certificate stating motor performance

After evlauate the test certificate Inmetro releases motors license

More information at www.inmetro.gov.br (Portaria 488)

European electrical design is not

registered on Inmetro!

Required Label

Page 15: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz

Required Label

Labeling South Korea

MEPS South Korea (KEMCO) *

Applicable to:

Closed and open enclosures

Motors 2, 4, 6 and 8 poles

Ratings from 0.75 to 200kW

Voltage up to 600V

Frequency: 60Hz

Not applicable to:

TEAO and TENV

Smoke Extraction

Marine and 2 speed motors

Motors with sleeve or thrust bearings

Motors without this label will

not be allowed through

Korean customs!

Not Certified

Hazardous area motors

* Motors Exclusively manufactured at WNT

Page 16: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz

Labeling Middle East

Efficiency Level

Most of Middle East countries

do not have a minimum

efficiency requirement.

Cyprus, Israel and Turkey are

the exceptions, adopting the

same requirement as Europe

(IEC IE2).

Saudi Arabia is studying also

adopting IEC IE2.

Although IEC is generally

adopted, for some specific

projects NEMA efficiency

levels may be required.

Nameplate shall record :

Efficiency level (IE2/IE3)

Efficiency values for 50, 75 and 100% load

CE mark

Requirements (only for Cyprus, Israel and Turkey)

Page 17: Energy Efficiency Programs Worldwide - WEGstatic.weg.net/medias/h5e/h61/Energy-Efficiency...Motors 2, 4, 6 and 8 poles Ratings from 0.75 to 200kW Voltage up to 600V Frequency: 60Hz