ENERGY EFFICIENCY NATIONAL BUILDING … and Us… ·  · 2015-07-23Develop and implement energy...

50
Development Management Department 1 of 49 ENERGY EFFICIENCY NATIONAL BUILDING REGULATIONS

Transcript of ENERGY EFFICIENCY NATIONAL BUILDING … and Us… ·  · 2015-07-23Develop and implement energy...

Development Management Department

1 of 49

ENERGY EFFICIENCY

NATIONAL BUILDING REGULATIONS

Development Management Department

2 of 49

EE

– N

BR

BACKGROUND

EE

- N

BR

Development Management Department

3 of 49

EE

– N

BR

National Energy Efficiency Strategy

of the Republic of South Africa

March 2005 ( Reviewed 2008 / 2011 )

EE

- N

BR

Development Management Department

4 of 49

EE

– N

BR

OBJECTIVES

● Develop and implement energy efficiency practices in SA

● Contribute to affordable energy for all

● Minimise the negative effects of energy usage upon

● human health and the environment

● Set a national target for energy efficiency improvement

● [ 12% by 2015 ]

● Cover all energy-using sectors

EE

- N

BR

Development Management Department

5 of 49

EE

– N

BR

ACHIEVED THROUGH

● Economic and legislative means

● Efficiency labelling

● Performance standards

● Energy management

● Energy auditing

● Promote efficiency practices

National Building Regulations and

Building Standards Act (Act No. 103 of 1977)

SANS 10400-XA SANS 204

SANS 10252 EE

- N

BR

Development Management Department

6 of 49

EE

– N

BR

ENERGY USAGE SECTORS

● Industry and Mining

● Commercial and Public Buildings

● Residential

● Transport

EE

- N

BR

Development Management Department

7 of 49

EE

– N

BR

EE

- N

BR

Development Management Department

8 of 49

EE

– N

BR

National Building Regulations

and

Building Standards Act

No. 103 of 1977

EE

- N

BR

Development Management Department

9 of 49

EE

– N

BR

09 November 2011

EE

- N

BR

Development Management Department

10 of 49

EE

– N

BR

Part X: Environmental sustainability

XA: Energy usage in buildings

EE

- N

BR

Development Management Department

11 of 49

EE

– N

BR

XA: Energy usage in buildings

XA1

● To contribute to the reduction of greenhouse gases

– buildings, and

– extensions to buildings

of occupancy classifications... EE

- N

BR

Development Management Department

12 of 49

EE

– N

BR

● A1 - Entertainment and public assembly

● A2 - Theatrical and indoor sport

● A3 - Places of instruction

● A4 - Worship

● C1 - Exhibition hall

● C2 - Museum

● E1 - Place of detention

● E2 - Hospital

● E3 - Other institutional (residential)

● E4 - Health care

● F1 - Large shop

● F2 - Small shop

● F3 - Wholesaler's store

● G1 - Offices

● H1 - Hotel

● H2 - Dormitory

● H3 - Domestic residence

● H4 - Dwelling house

● H5 - Hospitality

excluding: garage and storage areas contained within such occupancies

Not covered by NBR Part X A5 - Outdoor sport B1 - High risk commercial service B2 - Moderate risk commercial service B3 - Low risk commercial service D1 - High risk industrial D2 - Moderate risk industrial D3 - Low risk industrial D4 - Plant room

EE

- N

BR

Development Management Department

13 of 49

EE

– N

BR

shall be designed and constructed so that they...

EE

- N

BR

Development Management Department

14 of 49

EE

– N

BR

(a)

● use energy efficiently in relation to:

– vertical transport;

– thermal comfort;

– lighting; and

– hot water; or... EE

- N

BR

Development Management Department

15 of 49

EE

– N

BR

(b)

● have:

– building envelope; and

– services

which facilitate efficient use of energy appropriate to their:

● function and use,

● internal environment; and

● geographical location.

EE

- N

BR

Development Management Department

16 of 49

EE

– N

BR

EE

- N

BR

Development Management Department

17 of 49

EE

– N

BR

EE

- N

BR

13 Climatic Zones

Development Management Department

18 of 49

EE

– N

BR

EE

- N

BR

8 Climatic Zones

Development Management Department

19 of 49

EE

– N

BR

Equipment and plant for conducting business – excluded.

EE

- N

BR

Development Management Department

20 of 49

EE

– N

BR

XA2

● At least 50% annual average hot water heating shall be:

– by means other than electrical resistance heating

● including but not limited to:

– solar heating;

– heat pumps;

– heat recovery systems / processes; and

– renewable combustible fuel.

(volume fraction) calculated in accordance with SANS 10252-1

EE

- N

BR

Development Management Department

21 of 49

EE

– N

BR

XA3

● XA1 shall be deemed satisfied when:

– building is:

● designed; and

● constructed

in accordance with - EE

- N

BR

Development Management Department

22 of 49

EE

– N

BR

(a)

● SANS 10400-XA requirements for:

– orientation;

– shading;

– services; and

– building envelope; or...

EE

- N

BR

Development Management Department

23 of 49

EE

– N

BR

(b)

● rational design prepared by competent person:

– which demonstrates that energy usage of building is:

● equivalent to; or

● better than;

that which would be achieved by compliance with

SANS 10400 XA, or...

EE

- N

BR

Development Management Department

24 of 49

EE

– N

BR

(c)

● theoretical energy usage performance,

– less than; or

– equal to;

a reference building in compliance with SANS 10400-XA :

( using certified thermal calculation software )

certified thermal calculation software software certified by Agrément SA, in terms of Agrément SA Energy Software Protocols

EE

- N

BR

- BSIMAC (Version 9) Building Energy Analysis Software

- DesignBuilder (Version 3.1) Building Energy Analysis Software

- IES Virtual Environment Software (Version VE 2013)

- StarFront Software for designing compliant aluminium windows and doors

Development Management Department

25 of 49

EE

– N

BR

SANS 10400-XA

EE

- N

BR

Development Management Department

26 of 49

EE

– N

BR

(a) Functional regulations of part XA of NBR satisfied where:

● competent person certifies building as having:

– theoretical annual energy consumption; and

– theoretical annual energy demand

less than or equal to collected data tabled

● A1, A2, A3, A4, F1, G1, or H1,

● (excluding garage and storage areas), or...

A1 - Entertainment and public assembly A2 - Theatrical and indoor sport A3 - Places of instruction A4 – Worship F1 - Large shop G1 – Offices H1 - Hotel

EE

- N

BR

Development Management Department

27 of 49

EE

– N

BR

EE

- N

BR

Development Management Department

28 of 49

EE

– N

BR

(b) Functional regulations of part XA of NBR satisfied where:

● building:

– orientation;

– shading;

– external walls;

– fenestration;

– roof assembly construction;

– in-slab heating installation;

– services that use energy or control the use of energy:

● heating, air conditioning and mechanical ventilation;

– hot water system

is in accordance with requirements of SANS XA & 204

EE

- N

BR

Development Management Department

29 of 49

EE

– N

BR

● A1 - Entertainment and public assembly

● A2 - Theatrical and indoor sport

● A3 - Places of instruction

● A4 - Worship

● C1 - Exhibition hall

● C2 - Museum

● E1 - Place of detention

● E2 - Hospital

● E3 - Other institutional (residential)

● E4 - Health care

● F1 - Large shop

● F2 - Small shop

● F3 - Wholesaler's store

● G1 - Offices

● H1 - Hotel

● H2 - Dormitory

● H3 - Domestic residence

● H4 - Dwelling house

● H5 - Hospitality

EE

- N

BR

Development Management Department

30 of 49

EE

– N

BR

(c) Functional regulations of part XA of NBR satisfied where:

● competent person certifies building as having:

– theoretical annual energy consumption; and

– theoretical annual energy demand

less than or equal to reference building complying with (b) EE

- N

BR

Development Management Department

31 of 49

EE

– N

BR

RESPONSIBILITY

for

DESIGN ACHIEVING COMPLIANCE ?

EE

- N

BR

LOCAL AUTHORITY

WHY ??

Development Management Department

32 of 49

EE

– N

BR

AZ4 Complying with the requirements of the

National Building Regulations

(1) National Building Regulations shall be complied with by:

(a) adhering to all prescriptive regulations; and

(b) satisfying all functional regulations by:

(i) adopting solutions that comply with SANS 10400;

or

(ii) rational design / assessment having equivalent /

superior performance to solution complying with

SANS 10400.

EE

- N

BR

Development Management Department

33 of 49

EE

– N

BR

PART A - ADMINISTRATION

A1 APPLICATION

(1) Designing, planning and the supervision of the erection of any

building or structure...

...is subject to the provisions of any law in terms of which the

person undertaking such work...

...is required to be registered in terms of the

Architectural Profession Act, 2000,

Engineering Profession Act, 2000,…, or

any other relevant Act.

EE

- N

BR

Development Management Department

34 of 49

EE

– N

BR

A2 PLANS AND PARTICULARS TO BE FURNISHED

(1) Any person intending to erect any building shall submit to the

local authority the following plans and particulars,

together with the application:...

(g) a declaration by a person registered in a professional

category of registration...

...in Form 1 contained in SANS 10400-A

as to how the applicable functional regulations

shall be satisfied;

EE

- N

BR

Development Management Department

35 of 49

EE

– N

BR

DECLARATION FORM

EE

- N

BR

Development Management Department

36 of 49

EE

– N

BR

Identify the applicability of the Regulation i.t.o the proposal. Do NOT leave blank or tick both.

FORM 1

EE

- N

BR

Development Management Department

37 of 49

EE

– N

BR

FORM 1

Competent person is as defined in the related SANS 10400 code and are function specific.

Name of person to be appointed to be identified, not name of business representing

EE

- N

BR

Development Management Department

38 of 49

EE

– N

BR

FORM 2

Owner and competent person both initial confirming the work the competent person is responsible for and for which certification will be required on completion of the building. Such being necessary prior to applying for a Certificate of Occupation from the local authority.

The applicable duty is determined by that identified in Schedule B of Form 1.

EE

- N

BR

Development Management Department

39 of 49

EE

– N

BR

The acceptance of a competent person by a local authority is application specific and forms part of the approval of an application.

FORM 2

Aspects the local authority must consider when considering the acceptability of a competent person i.t.o the work for which appointed

Acceptability or Not of competent person to be endorsed by the local authority on consideration of the application

EE

- N

BR

Development Management Department

40 of 49

EE

– N

BR

EE

- N

BR

Development Management Department

41 of 49

EE

– N

BR

Competent person to identify the aspect/s for which the “Certificate of Completion” is

being issued

Certificate of Completion is issued i.t.o an “APPROVAL” granted by the local authority. Certificate of Completion cannot be issued i.t.o work for which no approval has been granted or which deviates from an approval granted (unauthorised work ?)

EE

- N

BR

Development Management Department

42 of 49

EE

– N

BR

RESPONSIBILITY

for

DESIGN ACHIEVING COMPLIANCE ?

EE

- N

BR

APPOINTED

REGISTERED PROFESSIONAL

OR

COMPETENT PERSON

Development Management Department

43 of 49

EE

– N

BR

VARIANCE FROM APPROVAL

IMPLICATIONS

EE

- N

BR

Development Management Department

44 of 49

EE

– N

BR

BUILDING APPLICATION APPROVAL

● Based on:

– Application & supporting documentation;

– Declaration by Appointed Registered Professional;

– Building Plans – NBR compliance EE

- N

BR

Development Management Department

45 of 49

EE

– N

BR

DEVIATION FROM APPROVAL

● Results in:

– Building Plan approval no longer being valid;

– Declaration by Registered Professional being voided;

– NBR compliance may no longer be possible.

Minor changes may have major impact on Energy Efficiency compliance achieved by original design solution

EE

- N

BR

Development Management Department

46 of 49

EE

– N

BR

Requirement for Water Layouts

SANS 10252-1

EE

- N

BR

Development Management Department

47 of 49

EE

– N

BR

Water Services Act

No. 108 of 1997

Regulations Relating to Compulsory National Standards

and Measures to Conserve Water

R 509 of 8 June 2001 EE

- N

BR

Development Management Department

48 of 49

EE

– N

BR

Consumer installations other than meters

14. Every consumer installation must comply with

- SABS 0252: Water Supply and Drainage for Buildings and

- SABS 0254: The Installation of Fixed Electric Storage Water

Heating Systems, or

any similar substituting re-enactment or amendment thereof if the

consumer installation is of a type regulated by either standard.

EE

- N

BR

Read as: SANS 10252 – 1 & 2 and SANS 10254

Development Management Department

49 of 49

EE

– N

BR

SANS 10400-XA

4.1.1

To comply with regulation XA2 :

(a) volume of annual average hot water heating requirements

shall be calculated i.t.o tables 2 and 5 of SANS 10252-1; and

(b) if solar water heating systems are used, these shall comply

with SANS 1307, SANS 10106, SANS 10254 and

SANS 10252-1.

EE

- N

BR

Development Management Department

50 of 49

EE

– N

BR

QUESTIONS ??

EE

- N

BR