Energy Efficiency in Thermal System - Case Studies from Nepal

67
DCCI Training Need Assessment 05.08.2013 Nepal Energy Efficiency Programme (NEEP) Component 3: Energy Efficiency in Industry

description

This presentation was held in the context of DCCI Capacity development Workshop December 2013 in Nepal. For further information go to our website.

Transcript of Energy Efficiency in Thermal System - Case Studies from Nepal

Page 1: Energy Efficiency in Thermal System - Case Studies from Nepal

DCCI Training Need Assessment 05.08.2013

Nepal Energy Efficiency Programme (NEEP) Component 3:

Energy Efficiency in Industry

Page 2: Energy Efficiency in Thermal System - Case Studies from Nepal

TS3: EE in Thermal System/ Case Studies

Bhishma PanditLong term Energy Efficiency ExpertGIZ/Integration

Page 3: Energy Efficiency in Thermal System - Case Studies from Nepal

Introduction to Thermal Energy• Energy in the form of the vibrations and

movements of microscopic particles• Heat is the common name for thermal energy

of an object that is due to the motion of the atoms and molecules that constitute the object.

Page 4: Energy Efficiency in Thermal System - Case Studies from Nepal
Page 5: Energy Efficiency in Thermal System - Case Studies from Nepal

Combustion

Fuel + Oxygen Oxides + HeatCombustion

Page 6: Energy Efficiency in Thermal System - Case Studies from Nepal

Combustion

Combustion reaction and heat liberation for One kg of molecule When there is complete combustion:

 

C + O2 CO2 + 7448 KCal/kg

 

2 H2 + O2 2H2O + 31500 KCal/kg

 

S + O2 SO2 +537.5 KCal/kg

Page 7: Energy Efficiency in Thermal System - Case Studies from Nepal

Calorific Value• The calorific value is the measurement of heat or energy

produced, and is measured either as gross calorific value or net calorific value.

• The difference being the latent heat of condensation of the water vapour produced during the combustion process.

Water vapourCarbon

Hydrogen

Sulphur

Moisture

GCV – 10,500 Kcal/kg

Water Vapour

Water Vapour

NCV – 9800 Kcal/kg

2

Page 8: Energy Efficiency in Thermal System - Case Studies from Nepal

Energy Costs and Heating Values

Type of Energy

Gross Calorific Value, KCal

Cost per Unit, NRs. Cost Per KCal

Coal 5000 / kg NRs. 24.0 / kg NRs 0.0048

Rice Husk 3200 / kg NRs. 6.25 / kg NRs. 0.002

Furnace Oil 9900 / liter NRs. 75 / liter NRs. 0.0075

HSD 9400/ liter NRs. 100/ liter NRs. 0.0107

Electricity 860 / kWh NRs. 7.10 / kWh NRs. 0.0083

TOTAL - - -

Page 9: Energy Efficiency in Thermal System - Case Studies from Nepal

Energy Cost for Dairy industryAverage specific fuel oil consumption of 8 liters per 1000 liters milk for the reference year 2011/12.

Page 10: Energy Efficiency in Thermal System - Case Studies from Nepal

Group Work: Rice Husk-??CV: 3200 kcal/kgHSD: 9400 kcal/liter

Page 11: Energy Efficiency in Thermal System - Case Studies from Nepal

Thermal Equipments Used in Industries

•Boilers•Furnaces •Refrigeration & Air Conditioning•Hot water Generators

Page 12: Energy Efficiency in Thermal System - Case Studies from Nepal

Introduction• It is an enclosed Pressure

Vessel• Heat generated by

Combustion of Fuel is transferred to water to become steam

• Process: Evaporation

• Steam volume increases to 1,600 times from water and produces tremendous force

• Care is must to avoid explosion. What is a boiler?

Page 13: Energy Efficiency in Thermal System - Case Studies from Nepal

Boilers

Page 14: Energy Efficiency in Thermal System - Case Studies from Nepal

Typical Boiler Specifications

• Boiler Make & Year :XYZ & 2003

• MCR(Maximum Continuous Rating) :10TPH (F & A 100oC)

• Rated Working Pressure :10.54 kg/cm2(g)

• Type of Boiler : 3 Pass Fire tube

• Fuel Fired : Fuel Oil• Heating surface : M2

Page 15: Energy Efficiency in Thermal System - Case Studies from Nepal

Furnace

Page 16: Energy Efficiency in Thermal System - Case Studies from Nepal

Performance Evaluation of a typical Furnace

Figure 4.10 Heat losses in industrial heating Furnaces

Page 17: Energy Efficiency in Thermal System - Case Studies from Nepal

INTRODUCTION

Refrigeration deals with the transfer of heat from a low temperature level at the heat source to a high temperature level at the heat sink.

– Air conditioning for comfort– Refrigeration for process

Page 18: Energy Efficiency in Thermal System - Case Studies from Nepal

TON OF REFRIGERATION

1 ton of refrigeration = 3024 kCal/hr heat

rejected.

The cooling effect produced is quantified as tons of refrigeration.

Page 19: Energy Efficiency in Thermal System - Case Studies from Nepal

VAPOUR-COMPRESSION REFRIGERATION SYSTEM (R-22)

Page 20: Energy Efficiency in Thermal System - Case Studies from Nepal

VAPOUR – ABSORPTION REFRIGERATION SYSTEM

EVAPORATOR

CONDENSOR

PUMP

GENERATOR

ABSORBER

STRONG

SOLUTION

WEAK

SOLUTION

COOLING WATER IN

HOT WATER OUT

THROTTLING VALVE

Regulating Valve

Waste Heat/

Direct Fired

Heat load In

Page 21: Energy Efficiency in Thermal System - Case Studies from Nepal

Efficiency

Page 22: Energy Efficiency in Thermal System - Case Studies from Nepal

Boiler Flue gas

Steam Output

Efficiency = 100 – (1+2+3+4+5+6+7+8)

(by In Direct Method)

Air

Fuel Input, 100%

1. Dry Flue gas loss2. H2 loss3. Moisture in fuel4. Moisture in air5. CO loss

7. Fly ash loss

6. Surface loss

8. Bottom ash loss

What are the losses that occur in a boiler?

Page 23: Energy Efficiency in Thermal System - Case Studies from Nepal

Trial DataFlue gas temperature after air preheater = 750oCAmbient temperature = 40oCPreheated air temperature = 190oC

Specific gravity of oil = 0.92Average fuel oil consumption = 400 Litres / hr

= 400 x 0.92 =368 kg/hrCalorific value of oil = 10000 kCal/kg

Average O2 percentage in flue gas =12%

Weight of stock = 6000 kg/hrSpecific heat of Billet = 0.12 kCal/kg/0CSurface temperature of roof and side walls = 122 oCSurface temperature other than heating and soaking zone = 85 oC

Page 24: Energy Efficiency in Thermal System - Case Studies from Nepal

Furnace Efficiency (Direct Method) Furnace Efficiency (Direct Method)

Fuel input = 400 litres / hr = 368 kg/hr Heat Input =368x10,000=3680000 kCal

Heat output = m x Cp x Δ T = 6000 kg x 0.12 x (1340 – 40) = 936000 kCal

Efficiency = Output x 100 Input

Efficiency = 936000 x 100 3680000

= 25.43 % = 25% (app) Losses = 75% (app)

Page 25: Energy Efficiency in Thermal System - Case Studies from Nepal

PERFORMANCE ASSESSMENT

The specific power consumption kW/TR is a useful indicator of the performance of refrigeration system. By messing refrigeration duty performed in TR and the Kilo Watt inputs measured, kW/TR is used as a reference energy performance indicator.

The refrigeration TR is assessed as TR = Q Cp (Ti – To) / 3024

Where TR is cooling TR duty Q is mass flow rate of coolant in kg/hr Cp is coolant specific heat in kCal /kg / 0C Ti is inlet. Temperature of coolant to evaporator (chiller) in 0C.To is outlet temperature of coolant from evaporator (chiller) in 0C.

Page 26: Energy Efficiency in Thermal System - Case Studies from Nepal

26

ENERGY AUDIT INSTRUMENTSRole : Instruments Play a vital role in energy audit to characterize and quantify energy.

To conserve energy, it is necessary to know how & how much energy is being consumed

Instruments also provide a means to monitor equipment performance and check condition

In order to arrive at the quantitative assessment, several fixed and portable instruments are used to measure the parameters related to.

Energy consumption data

Efficiency related data

Operation & control data

Page 27: Energy Efficiency in Thermal System - Case Studies from Nepal

27

Various Energy Audit Instruments

Various categories of portable energy audit instruments are

Thermal

Mechanical

Chemical

Electrical

Lighting

Page 28: Energy Efficiency in Thermal System - Case Studies from Nepal

28

Temperature can be measured by

Thermometer Thermocouple & Indicator Thermograph Data-logger Pyrometer Hygrometer

Thermal Measurements

Page 29: Energy Efficiency in Thermal System - Case Studies from Nepal

29

Flow Vane Anemometer

Pitot Tube

Ultra Sonic Flow Meter(For Liquids)

Multi Function KitFlow/VelocityPressureTemperatureRH

Contd..

Mechanical Measurements

Page 30: Energy Efficiency in Thermal System - Case Studies from Nepal

30

Pressure Bourden Gauge U Tube Manometer with pitot tube Pressure Recorder

Leaks Ultra Sonic Leak Checker

Speed Stroboscope Meter Contact Tachometer

Contd..

Page 31: Energy Efficiency in Thermal System - Case Studies from Nepal

31

Multifunction kit

Sound dB Meter

Time Stop watch

Measuring tape

Page 32: Energy Efficiency in Thermal System - Case Studies from Nepal

32

Flue Gas Analysis Oxyliser (O2, CO2 Temp, Efficiency)

Fyrite Kit (CO2 & O2)

Flue Gas Analyzer (CO2 & O2, CO, Temp, Efficiency)

Chemical measurements

Page 33: Energy Efficiency in Thermal System - Case Studies from Nepal

33

Application: Flow measurement of Liquids Parameters measured: Velocity & discharge of liquid flow Make: Panametrics, Ireland No of Sets: 01Range: 0.03 to 12.2 m/s (pipe size 2 to 24 inches)

Ultra-sonic Flow Meter

Page 34: Energy Efficiency in Thermal System - Case Studies from Nepal

34

Ultra-Sonic Flow Meter

Application: Flow measurement of Liquids Parameters measured: Velocity & discharge of liquid flow Make: Fuji, Japan No of Sets: 01Range: 0 to 32 m/s

Page 35: Energy Efficiency in Thermal System - Case Studies from Nepal

35

Application: Thermal and mechanical Parameters - velocity, temperature, pressure, humidity Make: Testo, Germany No of Sets:02 Range: 0.4 to 60 m/s, -200 to 1200oC, 0 to 100 hpa, 0 to 100% RH

Multi Function Kit

Page 36: Energy Efficiency in Thermal System - Case Studies from Nepal

36

Application: Speed Measurements Parameters measured: Speed of Rotating Element Make: Testo, Germany No of Sets: 2 Range: 20 to 20000 rpm

Non Contact Tachometer -Stroboscope

Page 37: Energy Efficiency in Thermal System - Case Studies from Nepal

37

Application: Measurement of Speeds Parameters measured: Speed (rpm) No of Sets:01

Contact Type Tachometer

Page 38: Energy Efficiency in Thermal System - Case Studies from Nepal

38

Application: Measurement of Air, gas velocity Parameters measured: Velocity Make: Lutron, Taiwan No of Sets:04 Range: 0 – 30 m/s

Digital Anemometer

Page 39: Energy Efficiency in Thermal System - Case Studies from Nepal

39

Application: Gas and air velocity, temperature in ductsMake: Airflow, England No of Sets:01 Range: 0.25 to 30 m/s and 0 – 80oC

Digital Hot wire Anemometer

Page 40: Energy Efficiency in Thermal System - Case Studies from Nepal

40

Application: Measurement of static, dynamic and total pressure in gas and air ducts Make: Air Flow, UK No of Sets: 1

Gas and Air Pressure measurement

Page 41: Energy Efficiency in Thermal System - Case Studies from Nepal

41

Application: Measurement of Air Leakages Parameters measured: Air Leakage Make: Air Flow, UK No of Sets:01

Leak Detector

Page 42: Energy Efficiency in Thermal System - Case Studies from Nepal

42

Application: Measurement liquid, gas and air pressureParameters measured: Pressure Make: Syscon, India No of Sets:01 Range: 0-50 bar

Digital Pressure Gauge

Page 43: Energy Efficiency in Thermal System - Case Studies from Nepal

43

Application: Measurement of Pressure Parameters measured: Pressure No of Sets: 3Range: 0 to 21 kg/cm2

Pressure & Vacuum Gauges

Page 44: Energy Efficiency in Thermal System - Case Studies from Nepal

44

Parameters measured: Dry bulb temperature & humidityMake: Gemini, USA No of Sets:04 Range: -15 to 150oC and 0-99 % RH

Digital temperature & humidity data logger

Page 45: Energy Efficiency in Thermal System - Case Studies from Nepal

45

Application: Measurement of Temperatures Parameters measured: Temperatures (8 temp. channels) Make: Grant, UK No of Sets:01Range: 0-1200oC

Temperature Data Logger

Page 46: Energy Efficiency in Thermal System - Case Studies from Nepal

46

Application: Measurement of Surface Temperatures Parameters measured: Surface Temperatures Make: Raytek, USA No of Sets:01 Range: -18 to 870oC

Non Contact Type Infrared Temperature Indicator

Page 47: Energy Efficiency in Thermal System - Case Studies from Nepal

47

Infrared Pyrometer

Application: Measurement of Surface Temperatures Parameters measured: Surface Temperatures Make: Raytek, USA No of Sets:02Range: -18 to 870oC

Page 48: Energy Efficiency in Thermal System - Case Studies from Nepal

48

Application: Measurement of temperatureParameters measured: Surface, gas and liquid temperaturesMake: Center, Taiwan No of Sets: 1Range: -50 to +400oC

Thermocouples & Temperature Indicator

Page 49: Energy Efficiency in Thermal System - Case Studies from Nepal

49

Application: Measurement of Temperature Parameters measured: Surface, gas and liquid temperatures Make: OMEGA No of Sets: 04Range: -50 to +1200 oC No of couples: 20

Digital Temperature Indicator

Page 50: Energy Efficiency in Thermal System - Case Studies from Nepal

50

Application: Measurement of Temperatures & humidity Parameters measured: Dry bulb temperature & humidity Make: Center, Taiwan No of Sets:01 Range:-20 to 60oC, 0 to 100% RH

Digital Temperature & Hygrometer

Page 51: Energy Efficiency in Thermal System - Case Studies from Nepal

51

Application: Measurement of Temperatures & humidity Parameters measured: Dry bulb temperature & humidity Make: IRA, India No of Sets:01 Range:0 to 50oC, 10 to 95% RH

Digital Temperature & Hygrometer

Page 52: Energy Efficiency in Thermal System - Case Studies from Nepal

52

Parameters measured: Dry bulb and Wet bulb temperatureMake: Lawrance & Mayo No of Sets:04 Range: 0- 50oC

Sling Hygrometer

Page 53: Energy Efficiency in Thermal System - Case Studies from Nepal

53

Application: Measurement of Flue Gas quantities Parameters measured: Co2 & O2 Make: Testo, Germany No of Sets:06 Range: 0 to 20% Co2; 0 to 21% O2

Combustion Test (Fyrite) Kit

Page 54: Energy Efficiency in Thermal System - Case Studies from Nepal

54

Application: Measurement O2 temperature and CO in flue gas pathsMake: Kane May, UK No of Sets: 1Range : O2 0-21% and CO upto 10000 ppm

Flue Gas Analyser

Page 55: Energy Efficiency in Thermal System - Case Studies from Nepal

55

Application: Measurement O2 temperature and CO in flue gas pathsMake: Neotronics, UK No of Sets: 1Range : O2 0-21% and CO upto 10000 ppm

Flue Gas Analyser

Page 56: Energy Efficiency in Thermal System - Case Studies from Nepal

56

Application: Measurement of Flue Gas Parameters Parameters measured:Co, Co2, No, No2, So2, Pressure, Efficiency Make: Krykard, Italy Range: O2-0 to 25%, CO-0 to 4000ppm,CO2- 0 to 20%, NO- 0 to 5000,No2-0 to 800 ppm, So2-0 to 500ppm, pressure- 0 to 150mbar/hpa, etc

Combustion Gas Analyser

Page 57: Energy Efficiency in Thermal System - Case Studies from Nepal

57

Flue Gas Analyser

Application: Measurement of Flue Gas Parameters Parameters measured:o2, Co, No, No2, So2, Humidity Make: TESTO, GermanyRange:02-0 to 21%, CO-0 to 20000 ppm, NO- 0 to 3000,No2-0 to 500 ppm, Humidity- 0 to 100%

Page 58: Energy Efficiency in Thermal System - Case Studies from Nepal

58

Application: Measurement of single phase Electrical Parameters Parameters measured: V, A, kW, kWh Make: Sagatron No of Sets:10 Range: 16A, 250V, 4 kW

Energy Monitor

Page 59: Energy Efficiency in Thermal System - Case Studies from Nepal

59

3-Phase Power Analyser

Application: Measures all Electrical and Harmonic Parameters Parameters measured: V, A, PF, KW, kVA, kVAr, Hz, first 50 Harmonics Make: Chauvan Arnaoux, France No of Sets: 01 Range: 830V, 3000A

Page 60: Energy Efficiency in Thermal System - Case Studies from Nepal

60

3-Phase Power Analyser

Application: Measures all Electrical and Harmonic Parameters Parameters measured: V, A, PF, KW, kVA, kVAr, Hz, first 50 Harmonics Make: RCC Technologies, Canada No of Sets: 01 Range: 600V, 1000A

Page 61: Energy Efficiency in Thermal System - Case Studies from Nepal

61

3-Phase Power Analyser

Application: Measures all Electrical and Harmonic Parameters Parameters measured: V, A, PF, KW, kVA, kVAr, Hz, Harmonics (first 25th) Make: Dossena, Italy No of Sets: 01Range: 600V, 1000A

Page 62: Energy Efficiency in Thermal System - Case Studies from Nepal

62

Portable Load Management System

Application: Measures all Power Parameters Parameters measured: V, A, PF, KW, kVA, kVAr, Hz Make: ALM-03 Krykard No of Sets: 01 Range: 750V, 1000A

Page 63: Energy Efficiency in Thermal System - Case Studies from Nepal

63

Application: Measures all power and Harmonic Parameters Parameters measured: V, A, PF, kW, kVA, kVAr, Hz, Harmonics Make: Fluke, WA No of Sets:02Range: Up to 600V, 1000A, 600 kW, up to 31st Level harmonics Accuracy

Handheld Power Harmonic Analyser

Page 64: Energy Efficiency in Thermal System - Case Studies from Nepal

Suppliers Challenges / Performance Monitoring and Guarantee

• Output performance test• Guarantee – efficiency• How to monitored the performance• Out put and input performance

Page 65: Energy Efficiency in Thermal System - Case Studies from Nepal

CasesCOST ECONOMICS OF REPLACING SMALL OIL-FIRED BOILER WITH RICE HUSK-FIRED

Page 66: Energy Efficiency in Thermal System - Case Studies from Nepal

Heat Recovery from ammonia compressor discharge

Desuperheater

Condenser

Compressor

Evaporator

Refrigerant

Water

Oil

Expansion valve

Oil Separator

Water In

Chilled Water

In Out

Water Out Hot Water Out

Cold Water in

Annual savings due to heat recovery – 6000 x 50/(0.85 x 10500) = 35 liters/day - 35 x Rs.75 x 350 - NRs. 9.2 lakhs

Page 67: Energy Efficiency in Thermal System - Case Studies from Nepal

Thank you . Thank you . Thank you . Thank you