energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description...
Transcript of energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description...
![Page 1: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/1.jpg)
94 | International catalogue 2015 www.grupotemper.com
04Movement-based
energy control
![Page 2: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/2.jpg)
95 International catalogue 2015 www.grupotemper.com
4.2.1 Ceiling-mount
4.2.2 Wall-mount
4.1 Microwave-based movement sensors
4.2 PIR-based movement sensors
4.3 Twilight switches
4.4 LED lights with sensor
4.5 Smoke detectors
![Page 3: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/3.jpg)
96 | International catalogue 2015 www.grupotemper.com
PRESENCE DETECTION CONTROL
Using passive infrared technology. Research and technology have developed highly sensitive sensors of infrared electromagnetic waves that are not visible to the human eye.
For example, thermometers for measuring temperature or pyroelectric detectors for measuring radiated heat are devices designed to detect electromagnetic waves in the infrared spectrum.
A "passive infrared detector" (PIR for short) records electromagnetic emissions with a wavelength of 5-20 microns, which includes the heat radiation of people or animals.
The sensor converts the thermal radiation of moving objects into electrical signals. The sensors themselves do not emit any radiation, which is why they are known as passive infrared sensors (PIR).
How do they do it?
Presence detectors are devices designed to detect moving heat sources within there feel of action and they turn the light on and off automatically.
PIR Technology1
![Page 4: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/4.jpg)
97 International catalogue 2015 www.grupotemper.com
A multi-segment FRESNEL lens is placed in front of the passive infrared sensor (PIR), which divides the area covered by the detector into a number of segments, so that they concentrate the infrared radiation received from the environment.
Each segment registers room temperature at rest, i.e. without movement, so that when the moving heat source crosses a segment, it registers a change in temperature.
When two consecutive segments are crossed by the moving body, an electrical signal that activates a relay output is generated under certain conditions, i.e. movement is captured.
Due to its operating principle, the movement is best detected when the detector is transversal, not frontal. Therefore two cover areas are differentiated in the sensor, depending on how the movement occurs.
The light fitting will be activated when not only movement is captured, but also the light level demanded by the user is greater than the ambient light level when the movement occurs.
In addition, the sensors time the lighting for a certain period after the movement so that, when people are still for short periods, the light does not go out.
FRESNEL sensor-lens
system
Typical applications
PRIVATE USE· Rooms · Corridors · Bathrooms · Basements and attics
· Garages · Parking
COMMERCIAL USE
· Stairs · Hotel corridors
· Lift landings · Corridors · WCs · Terraces
POINTS OF LIGHT
· Workshops · Entrance lamps
· Loading docks
![Page 5: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/5.jpg)
98 | International catalogue 2015 www.grupotemper.com
Installation recommendations
Is important to note the following points during planning and installation, so that the detectors operate in optimum fashion:
- The cover area increases proportionally with the height of the installation. At the same time, sensitivity is reduced and the individual segments are increased.
- For optimum detection, the movement must be transverse to the point of installation, i.e. the segments must be cut laterally.
- If someone comes to the front detector, it is more difficult for the sensor to register a temperature change, leading to a smaller coverage area.
- Fluctuations in ambient temperature caused by the seasons make detection conditions change. For example, in winter there is a greater difference between room temperature and human body temperature, which favours detection and increases the coverage area; however, people wear more clothes in winter and therefore the body does not give off so many infrared waves.
- Atmospheric phenomena such as rain, snow or fog can cause a decrease in the sensitivity of the detector and a reduction in its coverage area, since they absorb infrared waves and therefore the amount of infrared radiation that reaches the sensor is lower.
When selecting the point of installation, it is important to consider the following facts, which may cause interference:
- Animals, such as cats or dogs.
- Plants in motion, such as trees or shrubs.
- Fans and radiators.
- Lamps installed near the sensor.
- The detector must have an unobstructed field of view, since the infrared waves can not pass through doors, windows, glass partitions, etc.
![Page 6: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/6.jpg)
99 International catalogue 2015 www.grupotemper.com
Unlike PIR technology, microwave sensors (HF - High Frequency) only need movement for detection. Microwave sensors have an antenna that transmits ambient radiation waves at a frequency within the microwave spectrum. If an intruder enters the environment, the waves will be reflected on it and back to the device with a frequency offset (Doppler effect), then the sensor will enter alarm status.
This technology is active and more sensitive than PIR. It detects extremely small movements and, therefore, is ideal for detecting presence in offices, classrooms, etc. where people "sit still". Another advantage of HF technology is that the sensor does not need to "see" what is being detected, which can almost be hidden. Therefore, the sensor can be hidden in false ceilings, inside walls or behind thin, non-metallic objects. Furthermore, the microwave sensor is insensitive to dirt, unlike the PIR lens, where the performance is degraded if it is soiled, for example, in a dusty environment.
The microwave sensor is not affected by the temperature difference that can occur in different seasons; it is more stable than other technologies.
Microwave Technology2
Typical applications
PRIVATE OR COMMERCIAL USEDusty-areas with dirt or obstructions such as warehouses or car parks.
-Areas with draughts or vibrations.-Areas with activities that involve low-level mobility, workshops, offices, etc.
-Areas with temperature changes.-Areas that need hidden sensors for aesthetic reasons or for security.
Installation recommendations
The following must be taken into account for the installation:• The opening angle and range, and correct installation height.• If more than one microwave sensor is used, they must operate at different frequencies to prevent them from interfering with each other.• No sensors should be installed facing each other.• They must not be installed facing windows because microwaves pass through the glass
![Page 7: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/7.jpg)
100 | International catalogue 2015 www.grupotemper.com
Movement-based energy control
4.1 Microwave-based movement sensors
• Microwave technology movement sensor (5.8GHz).• Surface ceiling mounting.• Typical applications: specially suitable for dusty areas or areas with temperature changes, warehouses, garages, etc.
KDP16 360FP-HF
Article Code Packaging Power Description
KDP16 360FP-HF 0767800 1 220V-240V50 Hz
• Installation height: 1.5-3.5m • Detection angle: 360º• Max. sensing distance: Ø 16mm, adjustable • Set time: 10 s. to 12 min., adjustable • Twilight Range: <3-2000LUX, adjustable • Loads type Max (230V/127V) .: - Incandescent: 1200W - 800W - Halogen: 1200W - 800W - Fluorescent: 300W - 200W - Lamp. Low consumption 300W - 200W - LED: 300W - 200W• IP 20
KDP16 360FP-HF-127 8767800 1 110V-130V60 Hz
• Microwave technology movement sensor (5.8GHz).• Flush-mount ceiling mounting.• Typical applications: specially suitable for dusty areas or areas with temperature changes, warehouses, garages, etc.
KDP18 360FP-HF
Article Code Packaging Power Description
KDP18 360FP-HF 0767802 1 220V-240V50 Hz
• Installation height: 1.5-3.5m • Detection angle: 360º• Max. detection distance: Ø 16mm, adjustable • Time adjustment: 10 s. to 12 min., adjustable • Twilight Range: <3-2000LUX, adjustable • Loads type Max (230V/127V) .: - Incandescent: 1200W - 800W - Halogen: 1200W - 800W - Fluorescent: 300W - 200W - Lamp. Low consumption 300W - 200W - LED: 300W - 200W• IP 20
KDP18 360FP-HF-127 8767802 1 110V-130V60 Hz
110-130 V60 Hz
220-240 V50/60 Hz
110-130 V60 Hz
220-240 V50/60 Hz
![Page 8: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/8.jpg)
101 International catalogue 2015 www.grupotemper.com
Movement-based energy control
4.1 Microwave-based movement sensors
• Microwave technology movement sensor (5.8GHz).• Surface or flush mount ceiling (as accessories).• Typical applications can be installed at heights of 10 metres, suitable for use in buildings with high ceilings such as warehouses or gyms.• Compatible with KDP5 remote control.
PHOTO1. Great heights sensor
Article CodePackag-
ing Description
KDP5 0775866 1
· Power supply: 220-240V/AC• Installation height: 2.5-5m/5,5-10m • Detection angle: 360º• Detection distance: Ø 14-10m, Adjustable • Time adjustment: 10 s. 30 min., (adjustable) + pulse 1s• Twilight Range: 10-2000LUX Adjustable • type loads (max.): - Incandescent: 1200W - Halogen: 1000W - Fluorescent: 900VA/100uF - Lamp. Low consumption 600VA/400W - LED: 400W• IP 40 with accessory to embed 0775876• IP 54 with accessory for surface 0775877
KDP3/5 ACCESSORIES FP 0775876 1 Flush-mount accessory
KDP3/5 SURFACE ACCESSORY 0775877 1 Accessory for surface mounting
• Microwave technology movement sensor (5.8GHz).• Wall mounting.• Typical applications: specially suitable for dusty areas or areas with temperature changes, warehouses, garages, etc.
KDP17 360FP-HF
Article Code Packaging Power Description
KDP17 360FP-HF 0767801 1 220V-240V50 Hz
• Installation height: 1.5-3.5m • Detection angle: 360º• Max. sensing distance: - Wall: 15 m. adjustable - Roof: 16 m. Ø Adjustable • Time adjustment: 10 s. to 12 min., adjustable • Twilight Range: <3-2000LUX, adjustable • Loads type Max (230V/127V) .: - Incandescent: 1200W - 800W - Halogen: 1200W - 800W - Fluorescent: 300W - 200W - Lamp. Low consumption 300W - 200W - LED: 300W - 200W• IP 44
KDP17 360FP-HF-127 8767801 1 110V-130V60 Hz
110-130 V60 Hz
220-240 V50/60 Hz
220-240 V50/60 Hz
![Page 9: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/9.jpg)
102 | International catalogue 2015 www.grupotemper.com
Movement-based energy control
PIR detectors 4.2/4.2.1 Ceiling mount
• PIR motion sensor technology.• Flush or surface mount in ceiling (with accessory).• Typical applications: ideal for use in industrial, residential and commercial installations. Its adjustable time and light selectors adjust to your needs according to different on and off functions.
KDP1 360FP. Flush-mount sensor
Article Code Packaging Description
KDP1 0775860 1
· Power supply: 220-240V (50/60Hz) • Installation height: 2.5m• Detection angle: 360º • Max. detection distance: Ø 7m adjustable • Time adjustment: 5sec. 30min (adjustable) + pulse 1s• Twilight range 10 -2000LUX (adjustable)• type loads (max.): - Incandescent: 2000W - Halogen: 1000W - Fluorescent: 900VA/100uF - Low consumption lamp: 600VA/400W - LED: 500VA/400W • IP 40 flush mounting• IP 44 with surface mount accessory 0775861
KDP1 surface mount accessory 0775861 1 Accessory for surface mounting
• PIR motion sensor technology.• Surface ceiling mounting.• Typical applications: ideal for use in industrial installations, residential and commercial installations. Its adjustable time selectors and light selectors adjust to your needs according to different on and off functions.
KDP19 360S
Article Code Packaging Description
KDP19 360S 0767807 1
· Power supply: 220-240V (50/60Hz) • Installation height: 2.2-4m• Detection angle: 360º • Max. detection distance: Ø 12mm, adjustable • Time adjustment: 7min 10sec (adjustable)• Twilight Range: 3-2000LUX (adjustable)• Type loads (max.): - Incandescent: 1200W - Halogen: 1200W - Fluorescent: 300W - Low consumption lamp: 300W - LED: 300W • IP 20 surface mount
220-240 V50/60 Hz
220-240 V50/60 Hz
![Page 10: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/10.jpg)
103 International catalogue 2015 www.grupotemper.com
Movement-based energy control
PIR detectors 4.2/4.2.1 Ceiling mount
• PIR motion sensor technology.• Ceiling flush mount. • Typical applications: ideal for use in industrial installations, residential and commercial installations. Its dual relay enables control of two channels separately (one for lighting control, and one for activating air conditioning, ventilation, heating or alarm).
KDP2 360FP. Flush-mount sensor
Article Code Packaging Description
KDP2 0775862 1
· Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m• Detection angle: 360º • Max. detection distance: Ø 7m adjustable • Time adjustment: 5sec. to 30 min. (Adjustable)• Twilight range 10 -2000LUX (adjustable)• Type loads (max.): - Incandescent: 2000W - Halogen: 1000W - Fluorescent: 300VA/150W - Low consumption lamp: 250VA/150W - LED: 150W • IP 44 • Compatible with remote KDP
• PIR motion detector technology.• Ceiling flush mount.• Typical applications: flush mount sensor for automatic control of lighting. With it you can select the desired values for lighting and on/off times at low cost and with energy savings. Specially designed for use at home, in stores, offices, conference rooms, classrooms, etc.
360 KDP3 flush mount sensor
Article Code Packaging Description
KDP3 0775863 1
· Power supply: 220-240V (50/60Hz) • Installation height: 2.5• Detection angle: 360º • Max. detection distance: Ø 8mm adjustable• Time adjustment: 10 sec. 30 min. (Adjustable)• Twilight range 10 -2000LUX (adjustable)• Type loads (max.): - Incandescent: 2000W - Halogen: 1000W - Fluorescent: 900VA/100uF - Low consumption lamp: 600VA/400W - LED: 500VA/400W • IP 40 with accessory for flush mount 0775876• IP 54 with accessory for surface mount 0775877• Compatible with KDP remote control
KDP3/5 ACCESSORIES FP 0775876 1 Flush-mount accessory
KDP3/5 SURFACE ACCESSORY 0775877 1 Accessory for surface mounting
NEXTINCORPORATION
220-240 V50/60 Hz
220-240 V50/60 Hz
![Page 11: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/11.jpg)
104 | International catalogue 2015 www.grupotemper.com
Movement-based energy control
PIR sensors 4.2/4.2.1 Ceiling mount
• Range of motion sensors for large surfaces, up to 20m. • Set of latest-generation lenses that make it possible to cover a large area. • Timing: from 5 sec. to 30 min. • Protection grade IP44• Suitable for incandescent, halogen and fluorescent lamps • Optional remote control. • Programmable with KDP remote control . • Load control according to motion detection and twilight level. • Twilight setting of 10-2000 lux. · Power supply: 220-240 VAC, 50-60 Hz.
KDP4 FP. Sensor for large surfaces
Article Code Packaging Description
KDP4 FP 0775880 1
• Detection angle: 360º • Maximum range at h = 2.5m: ø = 20m • Supply voltage: 220-240 V/50-60 Hz • Type loads (max.):- Incandescent: 2000W- Halogen: 100W- Fluorescent: 900VA/100 uF- Low consumption lamp: 600VA/400W- LED: 500 VA/400W
• PIR motion sensor technology.• Surface ceiling mounting.• Typical applications: ideal for use in industrial installations, residential and commercial installations. Its adjustable time selectors and light selectors adjust to your needs according to different on and off functions.
EFIMAT 360
Article Code Packaging Description
EFIMAT 360 0713103 1
Power: 127V-60Hz• Installation height: 2.2-4m• Detection angle: 360º• Maximum detection distance: 12mm (diameter)• Time adjustment: 7min to 5sec (adjustable)• Twilight Range: 10-2000LUX (adjustable)• Type loads (max.):- Incandescent: 800W- Halogen: 800W- Fluorescent: 200W- Low consumption lamp: 200W- LED: 200W• IP 20
220-240 V50/60 Hz
110-130 V60 Hz
![Page 12: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/12.jpg)
105 International catalogue 2015 www.grupotemper.com
Movement-based energy control
PIR sensors 4.2/4.2.1 Ceiling mount
• PIR motion sensor technology.• Ceiling flush mount.• Typical applications: flush mount sensor for automatic control of lighting. With it you can select the desired values for lighting and on/off times at low cost and with energy savings. Specially designed for use at home, in stores, offices, conference rooms, classrooms, etc.
KDP20 360FP
Article Code Packaging Power Description
KDP20 360FP 0767810 1 220V-240V50 Hz
• Installation height: 2-2.4m• Detection angle: 360º • Detection distance: Ø 6m. • Time adjustment: 10 sec. 15 min. (Adjustable)• Twilight range: 3 -2000LUX (adjustable)• Loads type Max (230V/127V) .: - Incandescent: 800W - 500W - Halogen: 800W - 500W - Fluorescent: 400W - 200W - Low consumption lamp: 400W - 200W - LED: 400W - 200W • IP 20
360FP-127 KDP20 8767810 1 110V-130V60 Hz
• PIR motion sensor technology.• Ceiling flush mount. • Typical applications: flush mount sensor for automatic control of lighting. With you can select the desired values for lighting and on/off times at low cost and with energy savings. Specially designed for use at home, in stores, offices, conference rooms, classrooms, etc.
KDP21 360FP
Article Code Packaging Description
KDP21 360FP 0767811 1
· Power supply: 220-240V (50/60Hz) • Installation height: 2-2.4m• Detection angle: 360º • Detection distance: max. Ø 6m.• Time adjustment: 10 sec. 15 min. (Adjustable)• Twilight Range: 3 -2000LUX (adjustable)• Type loads (max.): - Incandescent: 1200W - Halogen: 1200W - Fluorescent: 300W - Low consumption lamp: 300W - LED: 300W • IP 20
220-240 V50/60 Hz
110-130 V60 Hz
220-240 V50/60 Hz
![Page 13: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/13.jpg)
106 | International catalogue 2015 www.grupotemper.com
• PIR motion sensor technology.• Ceiling mounting surface.• Typical Applications: suitable for covering large areas (up to 4x20m).
KDP4 GS20
Article Code Packaging Description
KDP4 GS20 0775865 1
· Power supply: 220-240V (50/60Hz) • Installation height: 2.2-6m• Detection angle: 360º • Detection distance: Ø 20mm.• Time adjustment: 10 sec. 30 min. (Adjustable)• Twilight Range: 3 -2000LUX (adjustable)• Type loads (max.): - Incandescent: 2000W - Halogen: 2000W - Fluorescent: 1000W - Low consumption lamp: 1000W - LED: 1000W • IP 20
Movement-based energy control
PIR sensors 4.2/4.2.1 Ceiling mount
• PIR motion sensor technology.• Ceiling mounting surface. • Typical applications: It can be installed at heights of 10 metres, suitable for use in buildings with high ceilings such as warehouses or gyms.
KDP GA10
Article Code Packaging Power Description
KDP GA10 0767808 1 220
• Installation height: 4-10m• Detection angle: 360º • Detection distance: max 4x20m. • Time adjustment: 10 sec. 30 min. (Adjustable)• Twilight Range: 3 -2000LUX (adjustable)• Loads type Max (230V/127V) .: - Incandescent: 2000W - 1000W - Halogen: 2000W - 1000W - Fluorescent: 1000W - 500W - Low consumption lamp: 1000W - 500W - LED: 1000W - 500W • IP 20
KDP GA10-127 8767808 1 110
220-240 V50/60 Hz
110-130 V60 Hz
220-240 V50/60 Hz
![Page 14: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/14.jpg)
107 International catalogue 2015 www.grupotemper.com
Movement-based energy control
PIR sensors 4.2/4.2.1 Ceiling mount
• PIR motion sensor technology.• Ceiling flush mount. • Typical applications: ceiling-mount presence sensor for medium-sized interiors, such as offices, warehouses, kitchens, public toilets for automatic lighting control.
KDP9 360 supermini
Article Code Packaging Description
KDP9 360 supermini 0767812 1
· Power supply: 220-240V (50/60Hz) • Installation height: 2-3m (wall)/ 2.2-4m-2.5m (ceiling)• Detection angle: 120/360 • Detection distance: 3m/6m Ø.• Time adjustment: 5sec, 30sec, 1min, 3min, 5min, 8min (adjustable)• Twilight Range: 10-2000LUX (adjustable)• Loads type (Max.): Incandescent: 800W. Halogen: 800W fluorescent: 200W Lamp. low consumption: 200W and LED: 200W• IP 20
• PIR motion sensor technology.• Ceiling flush mount. • Typical applications: ceiling-mount presents sensor for medium-sized interiors, such as offices, warehouses, kitchens, public toilets for automatic lighting control.
KDP9 360 mini
Article Code Packaging Description
KDP9 0775864 1
· Power supply: 220-240V (50/60Hz) • Installation height: 2.5m• Detection angle: 360º • Detection distance: 6m • Time adjustment: 1min/5min/10min/15min + pulse 1sg• Twilight Range: 3-2000LUX (adjustable)• Type loads (max.): Incandescent: 2000W. Halogen: 1000W Fluorescent: 900VA/100uF • IP 40 (IP 20 power unit)
Remote control
Article Code Packaging Description
KDP remote control 0775874 1 Control for models KDP 2 KDP 3
KDP5 remote control 0775878 1 Control for model KPD 5
220-240 V50/60 Hz
220-240 V50/60 Hz
![Page 15: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/15.jpg)
108 | International catalogue 2015 www.grupotemper.com
Movement-based energy control
PIR sensors 4.2/4.2.2 Wall mount
• PIR motion sensor technology.• Wall.• Typical applications: infrared with automatic switch for indoors and outdoors. Its programming off and on will let you save energy. It is ideal for use in supermarkets, shops and factories and to control lighting in the home and office.
KDP10 180W
Article Code Packaging Description
KDP10 180W 0767805 1
· Power supply: 220-240V (50/60Hz) • Installation height: 1.8-2.5m• Detection angle: 180º • Detection distance: up to 12m (> 24ºC))• Set time: 10 sec., 7min.• Twilight Range: 3-2000LUX (adjustable)• type loads (max.): - Incandescent: 1200W - Halogen: 1200W - Fluorescent: 300W - Low consumption lamp: 300W - LED: 300W• IP 44
• PIR motion sensor technology.• Wall and ceiling mounting.• Typical applications: infrared with automatic switch for indoors and outdoors. Its programming off and on will let you save energy. It is ideal for use in supermarkets, shops and factories and to control lighting in the home and office.
KDP6. Wall-mount sensor
Article Code Packaging Description
KDP6 110 0775867 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2-3m• Detection angle: 110/180/270 • Detection distance: up to 10m (selectable)• Set time: 6 sec., 10 min.,• Twilight Range: 10 -2000LUX (adjustable)• type loads (max.): - Incandescent: 1000W (KDP6110/180), 1840W (KDP6 270) - Halogen: 500W (KDP6 110/180), 1000W (KDP6 270) - Fluorescent: 400VA (KDP6 270) • IP 44
KDP6 180 0775868 1
KDP6 270 0775869 1
220-240 V50/60 Hz
220-240 V50/60 Hz
220-240 V50/60 Hz
220-240 V50/60 Hz
![Page 16: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/16.jpg)
109 International catalogue 2015 www.grupotemper.com
Movement-based energy control
PIR sensors 4.2/4.2.2 Wall mount
• PIR motion sensor technology.• Mounting on wall surfaces. • Typical Applications: Ideal for use in corridors, stairways, bathrooms tools, basements, garages, etc.
KDP11 180W
Article Code Packaging Description
KDP11 180W 0767803 1
· Power supply: 220-240V (50/60Hz) • Installation height: 1.8-2.5m• Detection angle: 180º • Detection distance: max. 12m (> 24ºC))• Set time: 10 sec., 7 min.• Twilight Range: 3-2000LUX (adjustable)• type loads (max.): - Incandescent: 1200W - Halogen: 1200W - Fluorescent: 300W - Low consumption lamp 300W - LED: 300W• IP 44
• PIR motion sensor technology.• Mounting on wall surfaces. • Typical Applications: Ideal for use in corridors, stairways, bathrooms tools, basements, garages, etc.
KDP7. Surface-mount sensor
Article Code Packaging Description
KDP7 150 0775870 1
· Power supply: 220-240V (50/60Hz) • Installation height: 2m• Detection angle: 150th • Detection distance: up to 12m (> 24ºC))• Set time: 5sec. to 12min.• Twilight Range: 5-2000LUX (adjustable)• Loads type (Max.): Incandescent: 1000W. Halogen: 500W fluorescent: 200W Lamp. low consumption: 150W LED: 100W • IP 44
KDP7 180 0775871 1
· Power supply: 220-240V (50/60Hz) • Installation height: 2m• Detection angle: 180 • Detection distance: up to 12m (> 24ºC))• Set time: 5sec. to 12 min.• Twilight Range: 5-2000LUX (adjustable)• Loads type (Max.): Incandescent: 1000W. Halogen: 500W fluorescent: 200W Lamp. low consumption: 150W LED: 100W • IP 44
220-240 V50/60 Hz
220-240 V50/60 Hz
220-240 V50/60 Hz
![Page 17: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/17.jpg)
110 | International catalogue 2015 www.grupotemper.com
Movement-based energy control
PIR sensors 4.2/4.2.2 Wall mount
• PIR motion sensor technology.• Surface mount wall. • Typical Applications: Ideal for use in corridors, stairways, bathrooms tools, basements, garages, etc. and in environments with dirt/ dust or outdoors.
KDP12 180W IP65
Article Code Packaging Description
KDP12 180W IP65 0767804 1
• Installation height: 1.8-2.5m• Detection angle: 180º • Detection distance: max. 12m (> 24ºC))• Set time: 10sec., 7 min.• Twilight Range: 3-2000LUX (adjustable)• Loads type Max (230V/127V) .: - Incandescent: 1200W - 800W - Halogen: 1200W - 800W - Fluorescent: 300W - 200W - Low consumption lamp 300W - 200W - LED: 300W - 200W• IP 65
KDP12 180W IP65-127 8767804 1
• PIR motion sensor technology.• Wall and corner mount.• Typical Applications: Ideal for use in corridors, stairways, bathrooms tools, basements, garages.
KDP15 360W
Article Code Packaging Description
KDP15 360W 0767806 1
· Power supply: 220-240V (50/60Hz) • Installation height: 1.8-2.5m• Detection angle: 360º • Detection distance: max. 12m (> 24ºC))• Set time: 10 sec., 7 min.• Twilight Range: 3-2000LUX (adjustable)• type loads (max.): - Incandescent: 1200W - Halogen: 1200W - Fluorescent: 300W - Low consumption lamp 300W - LED: 300W• IP 44
220-240 V50/60 Hz
220-240 V50/60 Hz
110-130 V60 Hz
![Page 18: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/18.jpg)
111 International catalogue 2015 www.grupotemper.com
Movement-based energy control
PIR sensors 4.2/4.2.2 Wall mount
• PIR motion sensor technology.• Wall flush-mount (monoblock).• Typical applications: wall sensor with a switch that lets you control lighting. It is an apparatus for indoor use only. It is ideal for not very large spaces, shops, offices, homes, etc.
PHOTO1. Two-wire detector
Article Code Packaging Description
KDP8 2H 0775872 1
· Power supply: 220-240V (50/60Hz) • Installation height: 0.8-1.2m• Detection angle: 180º • Detection distance: max. 8m • Set time: 6s. to 12 min.• Twilight Range: 5 -2000LUX (adjustable)• type loads (max.): Incandescent: 400W. Halogen: 400W • IP 20
• PIR motion sensor technology.• Wall flush-mount (monoblock).• Typical applications: wall sensor with a switch that lets you control lighting. It is an apparatus for indoor use only. It is ideal for not very large spaces, shops, offices, homes, etc.
PHOTO1. Three-wire detector
Article Code Packaging Description
KDP8 3H 0775873 1
· Power supply: 220-240V (50/60Hz) • Installation height: 0.8-1.2m• Detection angle: 180º • Detection distance: max. 8m • Set time: 6s to 12 min.• Twilight Range: 5-2000LUX (adjustable)• type loads (max.): - Incandescent: 1600W - Fluorescent: 300VA max. - Halogen: 300W - Low power consumption: 120VA max. - LED: 120W.• IP 20
220-240 V50/60 Hz
220-240 V50/60 Hz
![Page 19: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/19.jpg)
112 | International catalogue 2015 www.grupotemper.com
Movement-based energy control
PIR sensors 4.2/4.2.2 Wall mount
• Motion detector PIR technology with built-in buzzer• Surface Mount.• Typical Applications: ideal for alert of access to commercial establishmentsIt Includes alarm/Off/Buzzer mode selector
KDPT-01
Article Code Packaging Description
KDPT-01 0713110 1
· Power supply: 9V dc • Detection angle: 140th• Maximum detection distance: 8m (diameter)• Sound level:> 70dB• IP 20
![Page 20: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/20.jpg)
113 International catalogue 2015 www.grupotemper.com
Movement-based energy control
![Page 21: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/21.jpg)
114 | International catalogue 2015 www.grupotemper.com
Movement-based energy control
Summary table motion detectors
FUNCTIONS
Ref
eren
ce
Tech
nolo
gy
Inst
alla
tion
.
Inst
alla
tion
he
ight
Ver.
Det
ecti
on a
ngle
Det
ecti
on d
is-
tanc
e
Ad
just
men
t Ti
mer
Bri
ght
ness
ad
just
men
t
IP
Load
s
Rem
ote
cont
rol
Rem
arka
ble
KDP16 360FP-HFKDP16 360FP-HF-127
07678008767800
Microwave (5.8GHz)
Ceiling (surface) 1.5-3.5m220-240Vac110-130Vac
360º Max. 8m 10”-12' 3-2000Lux 20Incandescent: 1200W/800W Halogen: 1200W/800W Fluores-cent: 300W/200W Low power consumption: 300W/200W LED:
300W/200W
KDP17 360FP-HFKDP17 360FP-HF-127
07678018767801
Microwave (5.8GHz)
Wall 1.5-3.5m220-240Vac110-130Vac
180/360 Max. 8m 10”-12' 3-2000Lux 44Incandescent: 1200W/800W Halogen: 1200W/800W Fluores-cent: 300W/200W Low power consumption: 300W/200W LED:
300W/200W
KDP18 360FP-HFKDP18 360FP-HF-127
07678028767802
Microwave (5.8GHz)
Ceiling (flush-mount) 1.5-3.5m220-240Vac110-130Vac
360º Max. 8m 10”-12' 3-2000Lux 20Incandescent: 1200W/800W Halogen: 1200W/800W Fluores-cent: 300W/200W Low power consumption: 300W/200W LED:
300W/200W
KDP5 0775866Microwave (5.8GHz)
* Ceiling (surface + Built)
2.5-10m 220-240Vac 360º Max. 14m 10"-30' 1 s. 10-2000Lux*
40/54Incandescent: 2000W Halogen: 1000W Fluorescent. 900VA/100uF
Low consumption 600VA/400W LED: 500VA/400WKDP5 High altitudes
KDP1-360FP 0775860 PIR * Ceiling (surface +Built) ≈2.5m 220-240Vac 360º Max. 7m 5"-30' 1 s. 10-2000Lux*
40/44Incandescent: 2000W Halogen: 1000W Fluorescent. 900VA/100uF
Low consumption 600VA/400W LED: 500VA/400W
KDP 19,360 FP 0767807 PIR Ceiling (surface) 2.2-4m 220-240Vac 360º Max. 12m 10"-7' 3-2000Lux 20Incandescent: 1200W, Halogen: 1200W, Fluorescent: 300W Low
power consumption: 300W LED: 300W
KDP2 0775862 PIR Ceiling (flush-mount) ≈2.5m 220-240Vac 360º Max. 7m 5"-30' 1 s. 10-2000Lux 44Incandescent: 2000W Halogen: 1000W Fluorescent: 300VA/150W
Low consumption 250VA/150W LED: 150WKDP
Double chan-nel
KDP3 0775863 PIRCeiling (surface +
Built)≈2.5m 220-240Vac 360º Max. 8m 10"-30' 1 s. 10-2000Lux
* 40/54
Incandescent: 2000W Halogen: 1000W Fluorescent: 300VA/150WLow power consumption: 250VA/150W LED: 150W
KDP
KDP20 360FP360FP-127 KDP20
07678108767810
PIR Ceiling (flush-mount) 2-2.4m220-240Vac110-130Vac
360º Max. 6m 10"-7' 3-2000Lux 20Incandescent: 800W/500W Halogen: 800W/500W Fluores-
cent: 400W/200W Low power consumption: 400W/200W LED: 400W/200W
KDP21 360FP 0767811 PIR Ceiling (flush-mount) 2-2.4m 220-240Vac 360º Max. 6m 10"-7' 3-2000Lux 20Incandescent: 1200W, Halogen: 1200W.
Fluoresc.: 300W Low power consumption: 300W LED: 300W
KDP4 GS20 0775865 PIR Ceiling (surface) 2.2-6m 220-240Vac 360º 4x20m 10"-30' 3-2000Lux 20Incandescent: 2000W Halogen: 2000W, Fluorescent: 1000W
Low consumption 1000W, LED: 1000WLarge stores
KDP GA10KDP GA10-127
07678088767808
PIR Ceiling (surface) 4-10m220-240Vac110-130Vac
360º 4x20m 10"-30' 3-2000Lux 20Incandescent: 2000W/1000W Halogen: 2000W/1000W Fluores-cent: 1000W/500W Low power consumption: 1000W/500W LED:
1000W/500W
Large heights and surfaces
KDP9 360 mini 0775864 PIR Ceiling (flush-mount) ≈2.5m 220-240Vac 360º Max. 6m 1 '/5'/10 '/15'/ 1 s. 3-2000Lux 40Incandescent: 2000W Halogen: 1000W
Fluorescent: 900VA/uF
KDP9 360 supermini 0767812 PIR Ceiling/wall (flush-mount)1.8-2.5m 2.2-4m
220-240Vac 120/360 Max. 3/6m 5"/30"/1 '/3'/5'/8' 10-2000Lux 20Incandescent: 800W Halogen: 800W, Fluorescent: 200W
Low consumption 200W LED: 200W
KDP6 110 0775867 PIR Ceiling and wall (surface) 2-3m 220-240Vac 110th Max. 10m 6"-10' 1 s. 10-2000Lux 44 Incandescent: 1000W Halogen: 500W
KDP6 180 0775868 PIR Ceiling and wall (surface) 2-3m 220-240Vac 180º Max. 10m 6"-10' 1 s. 10-2000Lux 44 Incandescent: 1000W Halogen: 500W
KDP6 270 0775869 PIR Ceiling and wall (surface) 2-3m 220-240Vac 270 Max. 10m 6"-10' 1 s. 10-2000Lux 44 Incandescent: 1000W Halogen: 500W Fluorescent: 400VA
KDP10 180W 0767805 PIR Wall (surface) 1.8-2.5m 220-240Vac 180º Max. 12m 10"-7' 3-2000Lux 44Incandescent: 1200W, Halogen: 1200W
Fluorescent 300W Low power consumption: 300W LED: 300W
KDP7 150 0775870 PIR Wall (surface) ≈2m 220-240Vac 150th Max. 12m 5"-12' 5-2000Lux 44Incandescent: 1000W Halogen: 500W Fluorescent: 200W Low
power consumption: 150W LED: 100W
KDP7 180 0775871 PIR Wall (surface) ≈2m 220-240Vac 180º Max. 12m 5"-12' 5-2000Lux 44Incandescent: 1000W Halogen: 500W Fluorescent: 200W Low
power consumption: 150W LED: 100W
KDP11 180W 0767803 PIR Wall (surface) 1.8-2.5m 220-240Vac 180º Max. 12m 10"-7' 3-2000Lux 44Incandescent: 1200W, Halogen: 1200W, Fluorescent: 300W
Low consumption 300W LED: 300W
KDP12 180W IP65 KDP12 180W IP65-127
07678048767804
PIR Wall (surface) 1.8-2.5m220-240Vac110-130Vac
180º Max. 12m 10"-7' 3-2000Lux 65Incandescent: 1200W/800W Halogen: 1200W/800W Fluores-cent: 300W/200W Low power consumption: 300W/200W LED:
300W/200WIP65
KDP15 180W 0767806 PIRCeiling/Wall (surface and
corners)1.8-2.5m 220-240Vac 360º Max. 12m 10"-7' 3-2000Lux 44
Incandescent: 1200W, Halogen: 1200W, Fluorescent: 300WLow consumption 300W LED: 300W
KDP8 2H 0775872 PIR Wall (box with mechanisms) 0.8-1.2m 220-240Vac 180º Max. 8m 6"-12' 5-2000Lux 20 Incandescent: 400W halogen: 400W Connection
2h.
KDP8 3H 0775873 PIR Wall (monoblock) 0.8-1.2m 220-240Vac 180º Max. 8m 6"-12' 5-2000Lux 20Incandescent: 1600W, Fluorescent: 300VA max, halogen. 300W
Low consumption 200VA max LED.: 120W.Connecting
3h.
![Page 22: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/22.jpg)
115 International catalogue 2015 www.grupotemper.com
FUNCTIONS
Ref
eren
ce
Tech
nolo
gy
Inst
alla
tion
.
Inst
alla
tion
he
ight
Ver.
Det
ecti
on a
ngle
Det
ecti
on d
is-
tanc
e
Ad
just
men
t Ti
mer
Bri
ght
ness
ad
just
men
t
IP
Load
s
Rem
ote
cont
rol
Rem
arka
ble
KDP16 360FP-HFKDP16 360FP-HF-127
07678008767800
Microwave (5.8GHz)
Ceiling (surface) 1.5-3.5m220-240Vac110-130Vac
360º Max. 8m 10”-12' 3-2000Lux 20Incandescent: 1200W/800W Halogen: 1200W/800W Fluores-cent: 300W/200W Low power consumption: 300W/200W LED:
300W/200W
KDP17 360FP-HFKDP17 360FP-HF-127
07678018767801
Microwave (5.8GHz)
Wall 1.5-3.5m220-240Vac110-130Vac
180/360 Max. 8m 10”-12' 3-2000Lux 44Incandescent: 1200W/800W Halogen: 1200W/800W Fluores-cent: 300W/200W Low power consumption: 300W/200W LED:
300W/200W
KDP18 360FP-HFKDP18 360FP-HF-127
07678028767802
Microwave (5.8GHz)
Ceiling (flush-mount) 1.5-3.5m220-240Vac110-130Vac
360º Max. 8m 10”-12' 3-2000Lux 20Incandescent: 1200W/800W Halogen: 1200W/800W Fluores-cent: 300W/200W Low power consumption: 300W/200W LED:
300W/200W
KDP5 0775866Microwave (5.8GHz)
* Ceiling (surface + Built)
2.5-10m 220-240Vac 360º Max. 14m 10"-30' 1 s. 10-2000Lux*
40/54Incandescent: 2000W Halogen: 1000W Fluorescent. 900VA/100uF
Low consumption 600VA/400W LED: 500VA/400WKDP5 High altitudes
KDP1-360FP 0775860 PIR * Ceiling (surface +Built) ≈2.5m 220-240Vac 360º Max. 7m 5"-30' 1 s. 10-2000Lux*
40/44Incandescent: 2000W Halogen: 1000W Fluorescent. 900VA/100uF
Low consumption 600VA/400W LED: 500VA/400W
KDP 19,360 FP 0767807 PIR Ceiling (surface) 2.2-4m 220-240Vac 360º Max. 12m 10"-7' 3-2000Lux 20Incandescent: 1200W, Halogen: 1200W, Fluorescent: 300W Low
power consumption: 300W LED: 300W
KDP2 0775862 PIR Ceiling (flush-mount) ≈2.5m 220-240Vac 360º Max. 7m 5"-30' 1 s. 10-2000Lux 44Incandescent: 2000W Halogen: 1000W Fluorescent: 300VA/150W
Low consumption 250VA/150W LED: 150WKDP
Double chan-nel
KDP3 0775863 PIRCeiling (surface +
Built)≈2.5m 220-240Vac 360º Max. 8m 10"-30' 1 s. 10-2000Lux
* 40/54
Incandescent: 2000W Halogen: 1000W Fluorescent: 300VA/150WLow power consumption: 250VA/150W LED: 150W
KDP
KDP20 360FP360FP-127 KDP20
07678108767810
PIR Ceiling (flush-mount) 2-2.4m220-240Vac110-130Vac
360º Max. 6m 10"-7' 3-2000Lux 20Incandescent: 800W/500W Halogen: 800W/500W Fluores-
cent: 400W/200W Low power consumption: 400W/200W LED: 400W/200W
KDP21 360FP 0767811 PIR Ceiling (flush-mount) 2-2.4m 220-240Vac 360º Max. 6m 10"-7' 3-2000Lux 20Incandescent: 1200W, Halogen: 1200W.
Fluoresc.: 300W Low power consumption: 300W LED: 300W
KDP4 GS20 0775865 PIR Ceiling (surface) 2.2-6m 220-240Vac 360º 4x20m 10"-30' 3-2000Lux 20Incandescent: 2000W Halogen: 2000W, Fluorescent: 1000W
Low consumption 1000W, LED: 1000WLarge stores
KDP GA10KDP GA10-127
07678088767808
PIR Ceiling (surface) 4-10m220-240Vac110-130Vac
360º 4x20m 10"-30' 3-2000Lux 20Incandescent: 2000W/1000W Halogen: 2000W/1000W Fluores-cent: 1000W/500W Low power consumption: 1000W/500W LED:
1000W/500W
Large heights and surfaces
KDP9 360 mini 0775864 PIR Ceiling (flush-mount) ≈2.5m 220-240Vac 360º Max. 6m 1 '/5'/10 '/15'/ 1 s. 3-2000Lux 40Incandescent: 2000W Halogen: 1000W
Fluorescent: 900VA/uF
KDP9 360 supermini 0767812 PIR Ceiling/wall (flush-mount)1.8-2.5m 2.2-4m
220-240Vac 120/360 Max. 3/6m 5"/30"/1 '/3'/5'/8' 10-2000Lux 20Incandescent: 800W Halogen: 800W, Fluorescent: 200W
Low consumption 200W LED: 200W
KDP6 110 0775867 PIR Ceiling and wall (surface) 2-3m 220-240Vac 110th Max. 10m 6"-10' 1 s. 10-2000Lux 44 Incandescent: 1000W Halogen: 500W
KDP6 180 0775868 PIR Ceiling and wall (surface) 2-3m 220-240Vac 180º Max. 10m 6"-10' 1 s. 10-2000Lux 44 Incandescent: 1000W Halogen: 500W
KDP6 270 0775869 PIR Ceiling and wall (surface) 2-3m 220-240Vac 270 Max. 10m 6"-10' 1 s. 10-2000Lux 44 Incandescent: 1000W Halogen: 500W Fluorescent: 400VA
KDP10 180W 0767805 PIR Wall (surface) 1.8-2.5m 220-240Vac 180º Max. 12m 10"-7' 3-2000Lux 44Incandescent: 1200W, Halogen: 1200W
Fluorescent 300W Low power consumption: 300W LED: 300W
KDP7 150 0775870 PIR Wall (surface) ≈2m 220-240Vac 150th Max. 12m 5"-12' 5-2000Lux 44Incandescent: 1000W Halogen: 500W Fluorescent: 200W Low
power consumption: 150W LED: 100W
KDP7 180 0775871 PIR Wall (surface) ≈2m 220-240Vac 180º Max. 12m 5"-12' 5-2000Lux 44Incandescent: 1000W Halogen: 500W Fluorescent: 200W Low
power consumption: 150W LED: 100W
KDP11 180W 0767803 PIR Wall (surface) 1.8-2.5m 220-240Vac 180º Max. 12m 10"-7' 3-2000Lux 44Incandescent: 1200W, Halogen: 1200W, Fluorescent: 300W
Low consumption 300W LED: 300W
KDP12 180W IP65 KDP12 180W IP65-127
07678048767804
PIR Wall (surface) 1.8-2.5m220-240Vac110-130Vac
180º Max. 12m 10"-7' 3-2000Lux 65Incandescent: 1200W/800W Halogen: 1200W/800W Fluores-cent: 300W/200W Low power consumption: 300W/200W LED:
300W/200WIP65
KDP15 180W 0767806 PIRCeiling/Wall (surface and
corners)1.8-2.5m 220-240Vac 360º Max. 12m 10"-7' 3-2000Lux 44
Incandescent: 1200W, Halogen: 1200W, Fluorescent: 300WLow consumption 300W LED: 300W
KDP8 2H 0775872 PIR Wall (box with mechanisms) 0.8-1.2m 220-240Vac 180º Max. 8m 6"-12' 5-2000Lux 20 Incandescent: 400W halogen: 400W Connection
2h.
KDP8 3H 0775873 PIR Wall (monoblock) 0.8-1.2m 220-240Vac 180º Max. 8m 6"-12' 5-2000Lux 20Incandescent: 1600W, Fluorescent: 300VA max, halogen. 300W
Low consumption 200VA max LED.: 120W.Connecting
3h.
Movement-based energy control
Summary table motion detectors
![Page 23: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/23.jpg)
116 | International catalogue 2015 www.grupotemper.com
• Twilight switch.• Wall. • Typical applications: the KIC1 with LUX adjustment is a twilight switch for turning incandescent and fluorescent lamps on and off.
PHOTO1. Twilight switch
Article Code Packaging Description
KIC1 0775875 1
· Power supply: 220-240V (50Hz) • Twilight Range: 5-2000LUX (adjustable)• Status: Red LED ON/OFF• Set delay time: ON 60sec. /OFF 60 sec. after LED ON or OFF• type loads (max.): - Incandescent: 10A - Fluorescent: 3A• Working temperature: -25 to 45ºC• IP 44
• Twilight switch.• DIN rail.• Typical applications: the KIC2 with LUX adjustment is a twilight switch for automatic turning on and off of incandescent and fluorescent lamps. For soiled environments, dust or outdoors.
KIC2. Twilight switch
Article Code Packaging Description
KIC2 0767818 1
• V supply: 220-240V (50Hz) • Twilight Range: 2-100LUX (adjustable)• Contact capacity: 20A• IP 65
Movement-based energy control
4.3 Twilight switches
220-240 V50/60 Hz
220-240 V50/60 Hz
![Page 24: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/24.jpg)
117 International catalogue 2015 www.grupotemper.com
Movement-based energy control
4.3 Twilight switches
• Surface Mount.• Typical Applications: ideal for automatic lighting control• IP44
Photocells
Article Code Packaging Description
KOBALIGHT 0713101 1
• Twilight threshold cut: 10-25 Lux • 120V-220V• 10A• 1200W• Blue Colour
KOBALIGHT ACCS 0713102 1• Bracket Set - photocell receptacle KOBALIGHT
KOBALIGHT RECEP 0713108 1 • KOBALIGHT photocell receptacle
MENS KOBALIGHT 0713109 1 • KOBALIGHT Photocell
220-240 V50/60 Hz
110-130 V60 Hz
KOBALIGHT ACCS KOBALIGHT RECEP MENS KOBALIGHT
![Page 25: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/25.jpg)
118 | International catalogue 2015 www.grupotemper.com
Movement-based energy control
4.4 LED lights with sensor
• Lamp with sensor.• LED and PIR Technology.• Typical applications: efficient interior lighting.
KLD1
Article Code Packaging Description
KLD1 0767813 1
· Power supply: 220-240V (50/60Hz) • Installation height: 2-2.4m• Detection angle: 360º • Detection distance: 3m/6m (selectable)• Set time: 5sec., 30sec., 1min., 3min., 5min., 8min. (Selectable)• Twilight Range: 10-2000LUX (adjustable)• Loads (Max.): 20W (108 pcs SMD LED) • IP 20• Colour Temperature: 4000 ° K• 1400 lumens
• Light fitting with ceiling mount sensor.• LED and PIR Technology.• Typical Applications: Outdoor lighting (under cover) for front of industrial buildings, gardens, porches, etc.
KLD2
Article Code Packaging Description
KLD2 0767814 1
· Power supply: 220-240V (50/60Hz) • Installation height: 1.8-2.5m• Detection angle: 180º • Detection distance: max. 12m (<24ºC))• Set time: 10 sec. 7 min. (Selectable)• Twilight Range: 3-2000LUX (adjustable)• Loads (Max.): 25W (12 pcs SMD LED) • IP 44• Colour Temperature: 6000 ° K• 1500 lumens
220-240 V50/60 Hz
220-240 V50/60 Hz
![Page 26: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/26.jpg)
119 International catalogue 2015 www.grupotemper.com
Movement-based energy control
4.4 LED lights with sensor
• Luminaire detector.• Microwave Technology and LED.• Typical applications: interior lighting in garages, basements, etc. or dirt or dust and outdoors.
KLD3-18
Article Code Packaging Description
KLD3-18 0767815 1
· Power supply: 220-240V (50/60Hz) • Transmission frequency: CW radar 5.8GHz ISM band• Installation height: 2-4m• Detection angle: 360º • Detection distance: 1-8M (<24°C))• Set time: 10 sec. to 12 min. (Selectable)• Twilight Range: 3-2000LUX (adjustable)• Loads (Max.): 18W (280 pcs SMD LED)• IP 65• Colour Temperature: 6000 ° K• 1350 lumens
• Light fitting with sensor.• Microwave Technology and LED.• Typical applications: interior lighting in garages, basements, etc. or dirt or dust and outdoors.
KLD3-36
Article Code Packaging Description
KLD3-36 0767816 1
· Power supply: 220-240V (50/60Hz) • Transmission frequency: CW radar 5.8GHz ISM band• Installation height: 2-4m• Detection angle: 360º • Detection distance: 1-8M (<24°C))• Set time: 10 sec. to 12 min. (Selectable)• Twilight Range: 3-2000LUX (adjustable)• Loads (Max.): 36W (602 pcs SMD LED)• IP 65• Colour Temperature: 6000 ° K• 2750 lumens
• Light E27 with sensor.• PIR and LED technology.• Typical Applications: ideal for replacing incandescent lamps for more efficient LED solution, for interiors.
KLD4
Article Code Packaging Description
KLD4 0767817 1
· Power supply: 110-240V (50/60Hz) • Installation height: 2-3.5m• Detection angle: 360º • Detection distance: 6m (<24ºC))• Set time: 120 sec.• Twilight Range: <20lux • Loads (Max.): 6W (12 pcs LED)• IP 20• Colour Temperature: 4000 ° K• 450 lumens
220-240 V50/60 Hz
110-130 V60 Hz
220-240 V50/60 Hz
220-240 V50/60 Hz
![Page 27: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/27.jpg)
120 | International catalogue 2015 www.grupotemper.com
Movement-based energy control
• Photoelectric smoke detector.• Battery operated, 9V.• Alarm volume: 85dB to 3.• Low battery warning.• Test button.• Easy installation with mounting bracket.• Surface mounting.
KDH-BAT. Photoelectric smoke detector
4.5 Smoke detectors
Article Code Packaging Description
KDH-BAT 0713107 1 • Photoelectric smoke detector.
![Page 28: energy control - Acem€¦ · KDP2 360FP. Flush-mount sensor Article Code Packaging Description KDP2 0775862 1 · Power supply: 220-240V (50/60Hz) • Installation height: 2.5 m •](https://reader033.fdocuments.us/reader033/viewer/2022050105/5f43ba954cadba14075d2622/html5/thumbnails/28.jpg)
121 International catalogue 2015 www.grupotemper.com