Simulating the Energy Performance of Holographic Glazings - gaia
ENERGY ACTIVE CURTAIN WALLING FACADES · passive solar protection without moving elements potential...
Transcript of ENERGY ACTIVE CURTAIN WALLING FACADES · passive solar protection without moving elements potential...
![Page 1: ENERGY ACTIVE CURTAIN WALLING FACADES · passive solar protection without moving elements potential for savings compared to conventional glazings (heating, cooling) glazed PVT collectors](https://reader034.fdocuments.us/reader034/viewer/2022043009/5f9abfad3d1fdd75e8493b73/html5/thumbnails/1.jpg)
1/10
ENERGY ACTIVE CURTAIN WALLING FACADES
![Page 2: ENERGY ACTIVE CURTAIN WALLING FACADES · passive solar protection without moving elements potential for savings compared to conventional glazings (heating, cooling) glazed PVT collectors](https://reader034.fdocuments.us/reader034/viewer/2022043009/5f9abfad3d1fdd75e8493b73/html5/thumbnails/2.jpg)
2/10
traditional building envelope
heat loss, heat gain, lighting, protection
energy generator with HVAC functions
and advanced shading
multifunctional, prefabricated elements (curtain walling modules)
energy active facade module, autonomous facade module
![Page 3: ENERGY ACTIVE CURTAIN WALLING FACADES · passive solar protection without moving elements potential for savings compared to conventional glazings (heating, cooling) glazed PVT collectors](https://reader034.fdocuments.us/reader034/viewer/2022043009/5f9abfad3d1fdd75e8493b73/html5/thumbnails/3.jpg)
3/10
prismatic glazing
integrated into triple glazing
PVT collector
integrated into opaque facade
total reflection for solar altitude 40° production of electricity and heat
from same area
![Page 4: ENERGY ACTIVE CURTAIN WALLING FACADES · passive solar protection without moving elements potential for savings compared to conventional glazings (heating, cooling) glazed PVT collectors](https://reader034.fdocuments.us/reader034/viewer/2022043009/5f9abfad3d1fdd75e8493b73/html5/thumbnails/4.jpg)
4/10
testing of prismatic triple glazing confirmed theoretical potential
sharp decrease in solar transmittance around 40°
selective transmission (winter, summer)
![Page 5: ENERGY ACTIVE CURTAIN WALLING FACADES · passive solar protection without moving elements potential for savings compared to conventional glazings (heating, cooling) glazed PVT collectors](https://reader034.fdocuments.us/reader034/viewer/2022043009/5f9abfad3d1fdd75e8493b73/html5/thumbnails/5.jpg)
5/10
energy active facade module solar transmission monitoring
![Page 6: ENERGY ACTIVE CURTAIN WALLING FACADES · passive solar protection without moving elements potential for savings compared to conventional glazings (heating, cooling) glazed PVT collectors](https://reader034.fdocuments.us/reader034/viewer/2022043009/5f9abfad3d1fdd75e8493b73/html5/thumbnails/6.jpg)
6/10
![Page 7: ENERGY ACTIVE CURTAIN WALLING FACADES · passive solar protection without moving elements potential for savings compared to conventional glazings (heating, cooling) glazed PVT collectors](https://reader034.fdocuments.us/reader034/viewer/2022043009/5f9abfad3d1fdd75e8493b73/html5/thumbnails/7.jpg)
7/10
prismatic glazing PVT collectors
▪ reduction of heat gain compared
to conventional triple glazing
▪ winter: 2- 8 %
▪ summer: 39 to 46 %
▪ savings potential
▪ 22 % cooling energy (compared
to clear triple glazing)
▪ 25 % heating energy (compared
to solar protection triple glazing)
▪ increase in production from same
envelope area compared to
combination of conventional
technologies
▪ heat : 35 %
▪ electricity: 39 %
![Page 8: ENERGY ACTIVE CURTAIN WALLING FACADES · passive solar protection without moving elements potential for savings compared to conventional glazings (heating, cooling) glazed PVT collectors](https://reader034.fdocuments.us/reader034/viewer/2022043009/5f9abfad3d1fdd75e8493b73/html5/thumbnails/8.jpg)
8/10
▪ increasing interest in multifunctional facades
▪ price as a main barrier
▪ prismatic glazings
▪ natural diffuse lighting without sharp shadows
▪ passive solar protection without moving elements
▪ potential for savings compared to conventional glazings (heating, cooling)
▪ glazed PVT collectors
▪ combined heat and power from same area
▪ 5-40 % higher energy gain
![Page 9: ENERGY ACTIVE CURTAIN WALLING FACADES · passive solar protection without moving elements potential for savings compared to conventional glazings (heating, cooling) glazed PVT collectors](https://reader034.fdocuments.us/reader034/viewer/2022043009/5f9abfad3d1fdd75e8493b73/html5/thumbnails/9.jpg)
9/10
autonomous facade module
▪ Peltier cooler (600 W)
▪ photovoltaics 0,9 kWp
▪ flat battery pack 3,1 kWh
▪ solar protection (blinds)
▪ artificial LED lighting
▪ controller
research on potential level of self-sufficiency in energy supply for typical office behind facade