endoSTORE VERTICAL - Cantel Medical · 2019-05-31 · Hygiene concept Cabinet available as single...

2
endoSTORE VERTICAL Drying & Storing System | Dry & Store System Specifications © 2018 BHT P/N 50098-1624-EN.EU Messerschmittstr. 11 86368 Gersthofen Germany Tel +49 (0) 821-27893-920 Fax + +49 (0) 821-27893-79 www.bht.de If you wish more information, contact our international team to advise you on the treatment solution which suits your needs best. Tel +49 (0) 211-90980-755 · E-Mail www.cantelmedical.eu Visit our website and convince yourself www.bht.de endoSTORE VERTICAL Drying and Storage Cabinet Dimensions (W/D/H) 1000 x 690 x 2250 mm Hygiene concept Cabinet available as single door and pass-through version Weight 315 kg (net) Operating temperature +10°C to +40°C Power input 145 W Electrical connection 100-240 VAC, 50-60 Hz Fuse Internal device: T4A, building: 16A Connection of endoscopes With separate quick-lock connectors Air connection Quality of compressed air ISO 8573-1:2010 class 1.4.1 Pressure 5-10 bar (72,5-145 psi) Demand 200 l/min (ANR) resp. 33 l/min @ 5 bar 7 CFM (ANR) resp. 1.2 CFM @ 72,5 psi Diameter (DN) 6 (1/4”) Interface RJ45 (10/100 Mbit) endoSTORE and FlexFix are trademarks of Cantel (Germany) GmbH.

Transcript of endoSTORE VERTICAL - Cantel Medical · 2019-05-31 · Hygiene concept Cabinet available as single...

Page 1: endoSTORE VERTICAL - Cantel Medical · 2019-05-31 · Hygiene concept Cabinet available as single door and pass-through version Weight 315 kg ... Air connection Quality of compressed

endoSTORE™ VERTICALDrying & Storing System | Dry & Store

System Specifications

© 2018 BHT P/N 50098-1624-EN.EU

Messerschmittstr. 11 86368 GersthofenGermanyTel +49 (0) 821-27893-920Fax + +49 (0) 821-27893-79www.bht.de

If you wish more information, contact our international team toadvise you on the treatment solution which suits your needs best.

Tel +49 (0) 211-90980-755 · E-Mail www.cantelmedical.eu

Visit our website and convince yourself www.bht.de

endoSTORE™ VERTICAL Drying and Storage CabinetDimensions (W/D/H) 1000 x 690 x 2250 mm

Hygiene concept Cabinet available as single door and pass-through version

Weight 315 kg (net)

Operating temperature +10°C to +40°C

Power input 145 W

Electrical connection 100-240 VAC, 50-60 Hz

Fuse Internal device: T4A, building: 16A

Connection of endoscopes With separate quick-lock connectors

Air connection Quality of compressed air ISO 8573-1:2010 class 1.4.1

Pressure 5-10 bar (72,5-145 psi)

Demand 200 l/min (ANR) resp. 33 l/min @ 5 bar 7 CFM (ANR) resp. 1.2 CFM @ 72,5 psi

Diameter (DN) 6 (1/4”)

Interface RJ45 (10/100 Mbit)

endoSTORE™ and FlexFix™ are trademarks of Cantel (Germany) GmbH.

Page 2: endoSTORE VERTICAL - Cantel Medical · 2019-05-31 · Hygiene concept Cabinet available as single door and pass-through version Weight 315 kg ... Air connection Quality of compressed

THE COMPLETE CIRCLE OF PROTECTION DRY & STOREAs the global vanguard in infection prevention, only Cantel delivers the Complete Circle of Protection, a full-value, proactive partnership dedicated to helping you remove risk, streamline operational efficiencies and optimize your success.

Bacteria pose significant risk to endoscopes during endoscope storage. Cantel’s transport, drying and storage solutions are designed to protect valuable inventory, reduce cross contamination touchpoints, eliminate moisture in the endoscope channels and control humidity. Higher humidity or moisture in endoscope channels is known to aid bacterial growth.

The hygienically safe drying cabinet for centralized and decentralized storage

Supplementary equipment for the endoSTORE™ VERTICAL Drying and Storage Cabinet

• For at least 8 flexible endoscopes.

• FlexFix™ Endoscope Holder: Individual and secure fixation of all common types of endoscopes.

• Compliant to standard DIN EN 16442:2015.

Hygienic safety and protective storage for the entire process

• Compliant to standard DIN EN 16442:2015 through active drying and continuous climate monitoring.

• Active channel drying with medical compressed air; Outdoor drying through intelligent air circulation; system separation reduces high filter costs.

• Increased patient safety due to continuous documentation of reprocessing and storage.

• RKI-compliant, hanging storage to protect the endoscopes.

• Efficient storage periods: Hygienically safe storage validated up to 72 hours. Short drying times for quick reusability.

• Sustainable endoscope protection through individual and flexible instrument positioning with the FlexFix™ Endoscope Holder System.

• Large capacity for up to 8 gastro- or coloscopes, 16 bronchoscopes or 32 ENT endoscopes.

Easy handling and endoscope protection with the endoSTORE™ VERTICAL Drying and Storage Cabinet

• Individual and secure fixation of each endoscope; free positioning depending on the required height.

• Safe grip through special magnets on all magnetic surfaces.

• Simple moving of the endoscope and the suspension as well as the fixtures for the insertion tube and power connectors.

• Long-lasting and innovative: Endoscope suspension made of durable and flexible material.

• Protective storage: prevention of damaging the endoscope by the adaptability of the fixations; no influence on the endoscopes by the magnetic holders.

• Easy disinfection of the inside surfaces of the cabinet due to removable magnetic fixing elements.

Multibox: Storage and documentation for up to four endoscopes on one storage place (e.g. bronchoscopes).

* Supplementary equipment cannot be retrofitted.

HYGIENERELIABILITYEFFICIENCY

SMART light: LED lighting function for status display (blue: active, green: finished, red: malfunction).

HIS Interface: Data interface between Hospital Information System (HIS) and drying cabinet. Additional link with HMS system of BHT.

Transfer: Record of all processsteps of central or decentralizedstorage at different locations.

Network print: Approach a network printer to print process data.

Label Print: Printing of processdata on a label printer.

Sensors: Recording of temperature, humidity and air pressure data; necessary to comply with DIN EN 16442.*

2D scan: Processing of 1D and 2D codes (e.g. QR).*

SMART connect: Interfacebetween drying cabinet and AER.Security check and data exchange(users and instruments).