ENCODERS FOR WIND TURBINES - all-electronics.de...at the Blade:! One rev of blade = one rev of...

3
Encoders that keep Wind Turbines spinning

Transcript of ENCODERS FOR WIND TURBINES - all-electronics.de...at the Blade:! One rev of blade = one rev of...

Page 1: ENCODERS FOR WIND TURBINES - all-electronics.de...at the Blade:! One rev of blade = one rev of encoder!One singleturn absolute encoder per blade!Humidity - proof! Shock and vibration

Encoders that keep

Wind Turbines spinning

Offices:EUROPEHENGSTLER GmbH Uhlandstraße 49D-78554 AldingenTel +49 (0) 7424-890 Fax +49 (0) 7424-89500 [email protected]

ASIADanaher ICGRoom 502, Building 6, Lane 280,Linhong Road, Changning DistrictShanghai 200335, ChinaTel.: +86-21-6128 9873Fax: +86-21-6128 [email protected]

NORTH AMERICA Dynapar1675 Delany RoadGurnee IL 60031-1282Tel. +1 847 6622666Fax +1 847 [email protected]

SOUTH AMERICAVeeder Root do BrasilRua Ado Benatti 92Sao Paulo SP CEP 05037-904Tel. +55 11 3879 6600Fax +55 1136119 [email protected]

DO

C 1

234.0

1 E

05/2

008

ENCODERS FOR WIND TURBINES

Type RI100 HSD37 AC58 AR62

Coding Incremental Incremental Absolute Absolute

Multiturn n.a. n.a. 12 Bit In Preparation

Technology Optical Magnetic

Application Generator Pitch Control

ST Resolution < 4096 < 5000 < 17 Bit 12 Bit

Interface HTL / TTL single ended / complementary

BiSS l l

SSI l l

SSI+sincos l

CanOpen l l

Profibus l

DeviceNet l

CC-Link l

Analog l

Parallel l

Shaft Style Hollow Shaft Solid Shaft

Shaft Diameter 16 mm < 22.54 mm 10 mm 10 or 12 mm

Electr. Insulation l l

Intelligent Alarm Output allows preventive Maintenance for both Absolute and Incremental Encoders:The ACURO series of Absolute encoders are actively monitoring their operational status. The internal sensor monitors permanently its operational parameters, such as remaining LED life, operating temperature, integrity

of position data. Prewarnings and alarms can be generated based on exeeding of defined limits.

The RI100 has the same remote diagnostic capabili-ties. It can be dialed up from outside and can be checked. This helps minimizing downtimes and improving the efficiency of your service organization.

Member of

Page 2: ENCODERS FOR WIND TURBINES - all-electronics.de...at the Blade:! One rev of blade = one rev of encoder!One singleturn absolute encoder per blade!Humidity - proof! Shock and vibration

GENERATOR SPEED FEEDBACK PITCH AND YAW-CONTROL

! Single-turn 12bit resolution! Shock resistance 200 g! Vibration resistance 20 g! Depth of 32 mm! Wash down duty! Protection Class IP69K! Temperature: -40…+100°C ! Optional stainless-steel (seawater proof)! Interfaces: CANopen, BiSS, SSI, analog

Pitch Control direct at the Blade:! One rev of blade =

one rev of encoder

! One singleturn absolute encoder per blade

! Humidity - proof

! Shock and vibration resistant

! Recommendation: AR62 - Magnetic ST

ACURO -XRobustR

Pitch Control direct at the Blade:! One rev of blade =

multiple revs of encoder

! One multiturn absolute encoder per blade

! Recommendation: AC58-MT

! Optimal together with load module

! Also applicable for yaw application

Pitch Control indirect via geared motor:! One rev of blade =

multiple revs of encoder

! One multiturn absolute encoder per motor

! AC58-MT, optional sinewave

! Also used for yaw-control

G

Y

P

Y

TMBy Dynapar

ACURO R

HEAVY DUTY HEAVY DUTY HEAVY DUTY

AR62 MAGNETIC ABSOLUTE

AC58 MULTITURNABSOLUTE

! Singleturn <17bit resolution! Temperature: -40…+100°C ! Optional stainless-steel

(seawater proof)! Interfaces: CANopen, BiSS, SSI,

Profibus, Parallel! Encoder accomplishes speed,

commutation and position

AC58 LOAD MODULE

G

P P

G

RI100 OPTICAL INCREMENTAL

HSD37 OPTICAL INCREMENTAL

'Incremental Speed Feedback for Generators'16, 18 25 mm hollow shaft, 17 mm tapered shaft'Up to 4096 pulses per revolution'High load bearings for long life'Electrically insulated shaft - No effect from EDI - currents'Intelligent alarm output for preventive maintenance'Rugged mechanical design, unbreakable disc'Short-circuit-proof output'DC 5...30 V supply, pole protection'Electrical robust: Disruptive voltage up to 2,5kV'Protection class IP 65'Connection via terminal box'Option: redundant output

'Incremental Speed Feedback for Generators'12, 15, 16 mm and 1/2", 5/8", 3/4" hollow shaft'Up to 5.000 pulses per revolution'High load bearings for long life'Intelligent alarm output for preventive maintenance'Rugged mechanical design, unbreakable disc'Short-circuit-proof output'DC 5...30 V supply, pole protection'Electrically and thermally insulated'Protection class NEMA4X / IP 66 / IP 67'Connection via MIL style conector'Option: redundant output

OPTION

Load module extends shock and vibration resistance of any size 58mm clamping flange encoder.

flexiblecoupling

ball bearings

Y

PP

Y

P

Page 3: ENCODERS FOR WIND TURBINES - all-electronics.de...at the Blade:! One rev of blade = one rev of encoder!One singleturn absolute encoder per blade!Humidity - proof! Shock and vibration

Encoders that keep

Wind Turbines spinning

Offices:EUROPEHENGSTLER GmbH Uhlandstraße 49D-78554 AldingenTel +49 (0) 7424-890 Fax +49 (0) 7424-89500 [email protected]

ASIADanaher ICGRoom 502, Building 6, Lane 280,Linhong Road, Changning DistrictShanghai 200335, ChinaTel.: +86-21-6128 9873Fax: +86-21-6128 [email protected]

NORTH AMERICA Dynapar1675 Delany RoadGurnee IL 60031-1282Tel. +1 847 6622666Fax +1 847 [email protected]

SOUTH AMERICAVeeder Root do BrasilRua Ado Benatti 92Sao Paulo SP CEP 05037-904Tel. +55 11 3879 6600Fax +55 1136119 [email protected]

DO

C 1

234.0

1 E

05/2

008

ENCODERS FOR WIND TURBINES

Type RI100 HSD37 AC58 AR62

Coding Incremental Incremental Absolute Absolute

Multiturn n.a. n.a. 12 Bit In Preparation

Technology Optical Magnetic

Application Generator Pitch Control

ST Resolution < 4096 < 5000 < 17 Bit 12 Bit

Interface HTL / TTL single ended / complementary

BiSS l l

SSI l l

SSI+sincos l

CanOpen l l

Profibus l

DeviceNet l

CC-Link l

Analog l

Parallel l

Shaft Style Hollow Shaft Solid Shaft

Shaft Diameter 16 mm < 22.54 mm 10 mm 10 or 12 mm

Electr. Insulation l l

Intelligent Alarm Output allows preventive Maintenance for both Absolute and Incremental Encoders:The ACURO series of Absolute encoders are actively monitoring their operational status. The internal sensor monitors permanently its operational parameters, such as remaining LED life, operating temperature, integrity

of position data. Prewarnings and alarms can be generated based on exeeding of defined limits.

The RI100 has the same remote diagnostic capabili-ties. It can be dialed up from outside and can be checked. This helps minimizing downtimes and improving the efficiency of your service organization.

Member of