Enabling High-Availability with multi-site, rack aware replication
Alex MaPrincipal Solutions Engineer
read/write/update
Active
SERVER 1
Active
SERVER 2
Active
SERVER 3
APP SERVER 1
COUCHBASE Client Library
CLUSTER MAP
COUCHBASE Client Library
CLUSTER MAP
APP SERVER 2
Shard 5
Shard 2
Shard 9
Shard
Shard
Shard
Shard 4
Shard 7
Shard 8
Shard
Shard
Shard
Shard 1
Shard 3
Shard 6
Shard
Shard
Shard
Replica Replica Replica
Shard 4
Shard 1
Shard 8
Shard
Shard
Shard
Shard 6
Shard 3
Shard 2
Shard
Shard
Shard
Shard 7
Shard 9
Shard 5
Shard
Shard
Shard
Couchbase Basics
• Docs distributed evenly across servers
• Each server stores both active and replica docs Only one server active at a time
• Client library provides app with simple interface to database
• Cluster map provides map to which server doc is on App never needs to know
• App reads, writes, updates docs
• Multiple app servers can access same document at same time
Auto-Failover
SERVER 4 SERVER 5
Replica
Active
Replica
Active
App Server 1
COUCHBASE Client Library
CLUSTER MAP
COUCHBASE Client Library
CLUSTER MAP
App Server 2
Active
SERVER 1
Shard 5
Shard 2
Shard 9Shard
Shard
Shard
Replica
Shard 4
Shard 1
Shard 8Shard
Shard
Shard
Active
SERVER 2
Shard 4
Shard 7 Shard 8
Shard
Shard Shard
Replica
Shard 6
Shard 3 Shard 2
Shard
Shard Shard
Active
SERVER 3
Shard 1
Shard 3
Shard 6Shard
Shard
Shard
Replica
Shard 7
Shard 9
Shard 5Shard
Shard
Shard
• App servers accessing Shards
• Requests to Server 3 fail
• Cluster detects server failedo Promotes replicas of
Shards to activeo Updates cluster map
• Requests for docs now go to appropriate server
• Typically rebalance would follow
Shard 1 Shard 3
Shard
Rack-Zone Awareness
©2014 Couchbase, Inc.
• Grouping of servers into server groups so that each group is on a physically separate rack
• Ensures that replica data partitions are not on the same rack as the primary partitions
Servers 1, 2, 3 on Rack 1
Servers 4, 5, 6 on Rack 2
Servers 7, 8, 9 on Rack 3
Cluster has 2 replicas (3 copies of data)
This is a balanced configuration
Rack-Zone Awareness
©2014 Couchbase, Inc.
• If a entire server rack fails, data is still available
• If a entire cloud zone or a region fails, data is still available
©2014 Couchbase, Inc. — Proprietary and Confidential 6
Ping times EC2 Regions
7
Cross Datacenter Replication (XDCR)
• Replicates continuously data FROM source cluster to remote clusters may be spread across geo’s
• Supports unidirectional and bidirectional operation
• Application can read and write from both clusters (active – active replication)
• Automatically handles node addition and removal
• Replication throughput scales out linearly
• Simplified Administration via console, REST, and CLI
©2014 Couchbase, Inc.
8
Cross Datacenter Replication (XDCR) – Single Node Type
33 2Managed Cache
Dis
k Q
ueue
Disk
Replication Queue
App Server
Memory-to-Memory Replication to other node
Doc
Doc Doc
XDCR Queue
(New in 3.0) Memory-to-Memory Replication to remote cluster
Doc
©2014 Couchbase, Inc.
9
Cross Datacenter Replication (XDCR)
©2014 Couchbase, Inc.
Unidirectional Replication
• Hot spare / Disaster Recovery
• Development/Testing copies
• Integrate to Connector e.g. Solr, ElasticSearch
• Integrate to custom consumer
10
Cross Datacenter Replication (XDCR)
©2014 Couchbase, Inc.
Bidirectional Replication
• Multiple Active Masters
• Disaster Recovery
• Datacenter Locality
©2014 Couchbase, Inc. — Proprietary and Confidential 11
Putting it all together
Ec2 West - Cluster Ec2 East- Cluster
Group 1West 1-a
Group 2West 1-b
Group 3West 1-c
Group 1East 1-a
Group 2East 1-b
Group 3East 1-c
XDCR
Q&A