1 Used symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

2 Important recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32.1 Aeration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

2.1.1 Chimney versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42.1.2 Forced flue versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

2.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42.3 Adapting to another gas type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53.1 Boilers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53.2 Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

4 Energy-saving boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

5 Start-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

6 Stopping the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

7 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

8 Alarm messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

2 DTG 1300 Eco.NOx Plus / V130 10/11/2009 - 300002784-001-F

1. Used symbols

1 Used symbols

Caution dangerRisk of injury and damage to equipment. Attention must bepaid to the warnings on safety of persons and equipmentSpecific informationInformation must be kept in mind to maintain comfort

ReferenceRefer to another manual or other pages in this instructionmanual

DHW: Domestic hot water

Congratulations on your choice of a high quality product. We strongly advise you to read the following instructions in order toguarantee the optimal operation of your appliance. We are sure that it will be entirely to your satisfaction and will meet with all ofyour expectations.

2 Important recommendations

For a proper operating of the boiler, follow carefully theinstructions.

Any intervention on the appliance and heating equipmentmust be carried out by a qualified technician.

The manufacturer is not liable for any improper use of theappliance or failure to maintain or install the unit correctly(the user shall take care to ensure that the system isinstalled by a qualified fitter).

Check that the appliance is properly set for the type of gasused.

Keep to the polarity shown on the terminals: phase (L),neutral (N) and earth .

Check the seal on the gas and water pipe connections.

Check regularly that the installation contains water and ispressurised.

To guarantee protection against the corrosion of domestichot water calorifiers fitted with a titanium anode (TitanActive System® protection system), always leave thecontrol panel switched on. To switch off the heating or thedomestic hot water, use the Summer or Antifreeze mode(Vacation).

310/11/2009 - 300002784-001-F DTG 1300 Eco.NOx Plus / V130

2. Important recommendations

2.1 Aeration

2.1.1 Chimney versions

Do not obstruct the air inlets in the room (even partially).

France: the cross section of the aeration vent, which is compulsoryin the boiler room in which the boiler is installed, must comply with theDTU 61.1 (P 45 204) standard and, in particular, with the instructionon boiler room layout (Book 1764 April 1982).Belgium:the cross-section of the aeration vents, which arecompulsory in the room in which the boiler is installed, must complywith the NBN D51-003 standard.

Germany: the cross section of the ventiliation vents, which arecompulsory in the room in which the boiler is installed, must complywith the VDI 2050 form 1 standard and with other prevailingregulations.Other countries: the cross section of the aeration inlet, which iscompulsory in the premises in which the boiler is installed, mustcomply with the standards in force in the country.

2.1.2 Forced flue versions

It is not necessary to provide ventilation of the premises in which theboiler is installed. Ventilation is required if a mechanical connectionto the gas exists.

2.2 Maintenance

- The servicing and cleaning of the boiler and the sweeping of theflue gas pipe and the bleed pot must be done at least once a yearby a qualified professional. We recommend taking out amaintenance contract.

- Regularly check the level of water in the system and top up ifrequired, taking care that cold water is not added suddenly into theboiler when it is hot. If this operation is repeated several times perseason, locate the leak and repair it.

Do not drain the installation, except in cases of absolutenecessity. For example: Several months' absence with therisk of ice in the building.

2.3 Adapting to another gas type

Belgium:The operations required to switch from one gas to another must becarried out by a SERV'elite technician.

Other countries:The operations required to switch from one gas to another must becarried out by your fitter.

4 DTG 1300 Eco.NOx Plus / V130 10/11/2009 - 300002784-001-F

3. Description

3 Description

3.1 Boilers

The models presented are marketed in the various countriesaccording to the countries' specific sales programme.

Package HE1 - HE2

8538N075

1 Condensing boiler module2 Electronic manometer3 Automatic air vent4 Expansion vessel (12 litres)5 Siphon6 Modulating pump7 Safety valve (3 bar)8 Inverter valve9 Stop cock10 Domestic hot water safety valve 7 bar11 Non-return valve12 Disconnector13 Funnel14 Domestic hot water tank15 Exchanger16 Domestic recirculation17 Cold water inlet18 Heating return19 Condensates discharge20 Heating outlet21 Domestic hot water22 Gas

510/11/2009 - 300002784-001-F DTG 1300 Eco.NOx Plus / V130

3. Description

Package HE3 - HE4 - HE13 - HE14

8538N100

1 Condensing boiler module2 Electronic manometer3 Automatic air vent4 Expansion vessel (12 litres)5 Siphon6 Modulating pump7 Safety valve (3 bar)8 Inverter valve9 Stop cock10 Domestic hot water safety valve 7 bar11 Non-return valve12 Disconnector13 Funnel14 Domestic hot water tank15 Exchanger16 Domestic recirculation17 Cold water inlet18 Heating return19 Condensates discharge20 Heating outlet21 Domestic hot water22 Gas23 Fire prevention valve

6 DTG 1300 Eco.NOx Plus / V130 10/11/2009 - 300002784-001-F

3. Description

Package GN1 - GN2

Package GN3 - GN4

1 Condensing boiler module (15 kW - 25 kW)2 Electronic manometer3 Siphon4 Heating return5 Condensates discharge6 Heating outlet7 Gas

1 Condensing boiler module (15 kW - 25 kW)2 Electronic manometer3 Automatic air vent4 Expansion vessel (12 litres)5 Siphon6 Modulating pump7 Safety valve (3 bar)8 Stop cock9 Non-return valve10 Filling valve11 Heating return12 Condensates discharge13 Heating outlet14 Gas15 Gas valve

710/11/2009 - 300002784-001-F DTG 1300 Eco.NOx Plus / V130

3. Description

3.2 Control panel

Electromechanical components

1 Main ON/OFF switch

2On light / AlarmRed LED lit: Burner in safety conditionFlashing red Led: abnormal operation

3 Safety control box reset button

4Timed circuit breaker (4 A)A second electrical safety device can be found on the card which is accessible when the hoods are removed. This is a fuse: F1 4 amperes, delayed action

8 DTG 1300 Eco.NOx Plus / V130 10/11/2009 - 300002784-001-F

3. Description

Display

1 Text and numerical display2 Graphic display bar for the programme in circuit A, B or C3 Light area: Reduced temperature heating period or tank load disabled4 Dark area: Comfort temperature heating period or tank load enabled5 Flashing cursor showing the current time6 Number display (current time, adjusted values, parameters, etc.)

7Active programme display, P1, P2, P3, P4orE: Summer mode activated

8 The arrows flash when setting values can be modified using the + and - keys9 Circuit operation symbols

A, B, C

Opening the 3-way valveClosing the 3-way valveDisplayed circuit pump onName of the circuit displayed

10 Symbol displayed above the active operating mode11 Symbols indicating that the following inputs/outputs are active

Burner onBurner on with an increase in the output levelBurner on with a reduction in the output levelDHW load pump onSummer modeDisplay of the water pressure in the boilerInsufficient pressure: add water (0 - 0.5 bar)Addition of water recommended (0.5 - 1 bar)Pressure correct (1 - 2 bar)Too much pressure (> 2 bar)

910/11/2009 - 300002784-001-F DTG 1300 Eco.NOx Plus / V130

3. Description

Keys accessible when the flap is closed

Setting the temperatures

Comfort temperature

Reduced temperature

Domestic hot water temperature

/ Is used to adjust the selected temperature

Operating mode selection keysAUTO Heating according to the time programme

Forced Comfort mode:- until midnight if flashes- all the time if is steadyForced Low mode:- until midnight if flashes- all the time if is steadyAntifreeze mode

Tank load enabled mode:- until midnight if flashes- all the time if is steady

10 DTG 1300 Eco.NOx Plus / V130 10/11/2009 - 300002784-001-F

3. Description

Keys accessible when the flap is open

Manual "Summer" shutdown keyThe heating is switched off and DHW production is ensured. The symbols and Su are displayed."Standard" programme keyReset of all time programmes

Fitter settings access key

Key for access to setting and measurements

Page scrolling

Line scrolling

Back to the title or the previous lineProgramming keys

Enter (per 1/2 hour) the comfort temperature period or tank load enabled (dark area)

Enter (per 1/2 hour) the reduced temperature period or tank load disabled (light area)

Return key

A.B.C. Circuit display selection keyPROG Active heating programme selection key (P1, P2, P3 or P4)

1110/11/2009 - 300002784-001-F DTG 1300 Eco.NOx Plus / V130

4. Energy-saving boiler

4 Energy-saving boiler

This boiler handles all the functionalities that one may expect of acondensing boiler. Cutting edge technologies have been used notonly in its exceptionally economic design in terms of finance andenergy, and therefore also of environmental protection, but have alsobeen applied to provide maximum comfort: heating for the wholehouse, hot water, incredibly simple to use and trouble-free operationthanks to its reduced noise level.The floor-standing gas condensing boiler is not content with using theheat contained in the exhaust gases (perceptible) but also takesadvantage of latent heat (hidden). This energy is extracted from thesteam produced during the combustion process and is not exploitedby conventional boilers. The exhaust gases are here cooled in theboiler in such a way that the steam condenses and the additional heatfrom the exhaust gases is introduced into the heating system. Aspecial algorithm (Active Condens System) optimises the flow andreturn temperature to the boiler during the tank loading phase, thanksto a modulation of the circulating pump activated by rotation. Theboiler's efficiency is thus always optimum and the drinking waterdraw-off capacity is increased.The boiler meets the requirements of the German Decree on energysavings (Energie-EinsparVerordnung, EnEV) and offers trulyexceptional value for money.

12 DTG 1300 Eco.NOx Plus / V130 10/11/2009 - 300002784-001-F

5. Start-up

5 Start-up

Initial commissioning must be done by a qualifiedprofessional.

1. Check the water pressure in the installation several times a year.Top up with more water if necessary.

2. Open the gas valve.

3. Control panel:Set the On/Off switch to .

Create a requirement for heat.

6 Stopping the boiler

Set the On/Off switch to .On the Off position , the domestic hot water calorifierfitted with a titanium anode is not protected againstcorrosion.

Precautions to take if there is a danger of frost

Heating circuit:Use a correctly dosed antifreeze to prevent the heating waterfreezing. If this cannot be done, drain the system completely. In allcases, consult the fitter.

Domestic hot water circuit:Drain the domestic water tank and pipes.

Precautions to take in the event of prolonged shutdown (one year or more)

- Close the gas valve- The boiler and the chimney must be swept carefully.

- Close the door of the boiler to prevent the internal circulation of air.

7 Troubleshooting

Checks to make before calling your fitter:The burner is not working:

It is cold.- If using a remote control (CDI2 or FM52), check that it is set

according to the instructions.It is cold. There is no domestic hot water.

- Check the temperature and time programme settings.- Note the alarm message.- Press button .- Release the button. The boiler restarts.- In the event of problems, see Alarm messages.

The burner is operating but the radiators are cold:Air and water noise in the radiators

- Bleed the radiators.- Top up the heating circuit with water.- If it is often necessary to top up the installation with water, contact

your fitter.- If the problem persists, consult your fitter.

The burner is operating but the radiators are cold

- If the problem persists, consult your fitter.Hot water takes a very long time to reach certain draw-off pointsand not othersThis is due to the length of the hot water pipes between the draw-offpoints and the boiler. The greater the length, the longer the timenecessary for the hot water to replace the colder water in the pipes.When you inform your fitter of an error, tell him:- Product type- Year of manufacture- Serial number- Type of gas usedThis information can be found on the rating plate affixed to theunderside of the domestic hot water tank.- Indicate the fault reading.

1310/11/2009 - 300002784-001-F DTG 1300 Eco.NOx Plus / V130

8. Alarm messages

8 Alarm messages

FaultsIn the event of a fault, the display may show the following messages. Contact your fitter.

Message Probable causes Solution

BURNER FAILURE

Igniter fault

Reset the safety control box. Contact your fitter.

Ionization errorGas valve defectiveNo gas or presence of air in the pipe

CVI8 FAILURE

Incorrect positioning of the electrodeIgnition cable or electrode connector defectiveInternal safety control box fault

CVI9 FAILURE

Electrical impulse fault on the gas valve controlPoor contact between the safety control box and the valveGas valve control in the safety control box is defective

CVI10-22 FAILURE Internal safety control box fault

CVI COM.FAULT Communication error between DIEMATIC and safety control box

MANOMETRE FAIL Fault on the water pressure sensor Switch off and reignite the boiler to restart heating for a period of 72 hours. (The message continues to be displayed.) Contact your fitter.

ROOM S.A FAIL.ROOM S.B FAIL.ROOM S.C FAIL.OUTL S.B FAIL.OUTL S.C FAIL.OUTSI. S.FAIL.SOLAR S. FAILFAN FAILURESWIM.P. S.FAIL

Fault in the corresponding sensor

Contact your fitter.

ST.TANK S.FAIL The hot water storage tank reheating operation is no longer assured

BOILER S.FAIL. Boiler sensor defectiveDHW S. FAILURE Domestic hot water sensor defectiveTA-S SHORT-CIR There is a short circuit in the TASTA-S DISCONNEC The TAS is in open circuitTA-S FAILURE Internal problem

14 DTG 1300 Eco.NOx Plus / V130 10/11/2009 - 300002784-001-F

8. Alarm messages

WarrantyYou have just purchased one of our appliances and we thank you

for the trust you have placed in our products. Please note that your

appliance will provide good service for a longer period of time if it is

regularly checked and maintained. Your fitter and our customer

support network are at your disposal at all times.

Warranty terms

Starting from the purchase date shown on the original fitter's

invoice, your appliance has a contractual guarantee against any

manufacturing defect.

The length of the guarantee is mentioned in the price catalogue.

The manufacturer is not liable for any improper use of the appliance

or failure to maintain or install the unit correctly (the user shall take

care to ensure that the system is installed by a qualified fitter). In

particular, the manufacturer shall not be held responsible for any

damage, loss or injury caused by installations which do not comply

with the following:

- applicable local laws and regulations

- specific requirements relating to the installation, such as national

and/or local regulations

- the manufacturer's instructions, in particular those relating to the

regular maintenance of the unit

- the rules of the profession

The warranty is limited to the exchange or repair of such parts as

have been recognised to be faulty by our technical department and

does not cover labour, travel and carriage costs. The warranty shall

not apply to the replacement or repair of parts damaged by normal

wear and tear, negligence, repairs by unqualified parties, faulty or

insufficient monitoring and maintenance, faulty power supply or the

use of unsuitable fuel. Sub-assemblies such as motors, pumps,

electric valves etc. are guaranteed only if they have never been

dismantled.

France

The preceding dispositions are not exclusive of benefits for the

purchaser of the legal guarantee as stated in Civil Code articles

1641 to 1648.

Poland

Warranty conditions are included in the warranty card.

Switzerland

The application of the warranty is subject to the terms and

conditions of sale, delivery and warranty of the company marketing

our products.

Belgium

The preceding dispositions about the contractual guarantee are not

exclusive of profit if the need arises for the purchaser in Belgium of

the applicable legal dispositions on hidden defects.

Italy

The duration of our warranty is shown on the certificate delivered

with the appliance.

Our liability as manufacturer may not be invoked in respect of

incorrect use of the appliance, incorrect or insufficient maintenance

thereof, or incorrect installation of the appliance (you must

therefore ensure that installation and maintenance operations are

carried out respectively by a qualified professional and by an after

sales service company).

The legislation laid down by European Directive 99/44/EEC,

transposed by Legislative Decree No. 24 of 2 February 2002

published in O.J. No. 57 of 8 March 2002, continues to apply.

Russia

The foregoing provisions in no way affect the rights of the

consumer, which are guaranteed by the legislation of the Russian

Federation as regards hidden defects.

The terms and conditions of warranty and the terms and conditions

of application of the warranty are indicated on the warranty form.

The warranty shall not apply as regards the replacement or repair

of wearing parts under normal use. Such parts include

thermocouples, injection nozzles, flame control and ignition

systems, fuses and gaskets.

Turkey

Due to the laws and regulations the product life for this product is

10 years. During that time the producer and/or the distributor has

to provide after sales services and spare parts.

Other countries

The above provisions do not restrict the benefit of the legal laws

regarding hidden defects applicable in the buyer's country.

1510/11/2009 - 300002784-001-F DTG 1300 Eco.NOx Plus / V130