EN 197˜1 ˜ CEM I 52,5 R - LAFARGE

15
Safety Data Sheet according to the 2015/830/EU amendment of REACH 1907/2006/EC regulation. Date of publication: 28 March 2018 Date of last review: 28 March 2018 Version: 1.00 PORTLANDCEMENT EN 197-1 - CEM I 52,5 R 52.5 R

Transcript of EN 197˜1 ˜ CEM I 52,5 R - LAFARGE

Page 1: EN 197˜1 ˜ CEM I 52,5 R - LAFARGE

Safety Data Sheet according to the 2015/830/EU amendment of

REACH 1907/2006/EC regulation.

Date of publication: 28 March 2018Date of last review: 28 March 2018

Version: 1.00

PORTLANDCEMENTEN 197-1 - CEM I 52,5 R

52.5 R

Page 2: EN 197˜1 ˜ CEM I 52,5 R - LAFARGE

2/15

PROC Identi d Uses - Use Description

Manufacture/ Formulation of

Professional/ Industrial use of

building and construction materials

2 Use in closed, continuous process with occasional controlled exposure X X

3 Use in closed batch process X X

5Mixing or blending in batch process for formulation

of mixtures and articlesX X

7 Industrial spraying X

8aTransfer of substance or mixture from/to vessels/large

containers at non-dedicated facilitiesX

8bTransfer of substance or mixture from/to vessels/large

containers a dedicated facilitiesX X

9 Transfer of substance or mixture into small containers X X

10 Roller application or brushing X

11 Non-Industrial spraying X

13 Treatment of articles by dipping and pouring X

14Production of mixtures or articles by tabletting,

compression extrusion, pelletisationX X

19 Hand-mixing with intimate contact and only PPE available X

22Potentially closed processing operations with minerals/metals

at elevated temperature in industrial settingX

26 Handling of solid inorganic substances at ambient temperature X X

1.3 Data about the supplier of the Safety Data Sheet

Manufacturer / Supplier LAFARGE Cement Hungary Ltd.Address 7953 Királyegyháza, 041/29 hrsz.Postal correspondence 7940 Szentlőrinc, Pf.: 54Name of manufacturer’s site LAFARGE Cement Magyarország Kft.Address of manufacturer’s site 7953 Királyegyháza, 041/29 hrsz.Telefon/fax +36 73 500 900 / +36 73 500 958 Name of assembler Dorottya TamásiHis/her email address [email protected] contact person Mátyás Kovács

1.4 Emergency phoneEgészségügyi Toxikológiai Tájékoztató Szolgálat (ETTSZ) 1096 Budapest, Nagyvárad tér 2.Language of information: HungarianService hours: 24/7 on-call serviceEmergency phone number: +36 80 201 199

Page 3: EN 197˜1 ˜ CEM I 52,5 R - LAFARGE

SECTION 2: HAZARD CLASSIFICATION

2.1.1. Hazard rates and categories, warnings as per 1272/2008/EC

Hazard rate Hazard category

Skin irritation Skin Irrit. 2 According to test results

Severe eye impairment Eye Dam. 1 According to test results

Skin irritability Skin Sens. 1 Based on a literature review

Toxicity on target organ – single exposure STOT SE 3 Based on a literature review

H315 Causes skin irritation.H317 May cause an allergic skin reaction.H318 Causes serious eye damage.H335 May cause respiratory irritation.

2.2 Labelling elements

2.2.1. According to Regulation (EC) No 1272/2008

H315 Causes skin irritation.H317 May cause an allergic skin reaction.H318 Causes serious eye damage.H335 May cause respiratory irritation.P280 Wear protective gloves/protective clothing/eye protection/face protection.

P305 + P351 + P338 + P310 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or doctor/physician.

P302 + P352 + P333 + P313 IF ON SKIN: Wash with plenty of soap and water. If skin irritation or rash occurs: Get medical advice/attention. P261 + P304 + P340 + P312 Avoid breathing dust/fume/gas/mist/vapours/spray. IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. Call a POISON CENTER or doctor/physician if you feel unwell.

3/15

GHS07 GHS05

Page 4: EN 197˜1 ˜ CEM I 52,5 R - LAFARGE

2.3 Additional hazardsIn accordance with Appendix XIII of the REACH Regulation 1907/2006/EC, the cement does not comply with the criteria for PBT or vPvB materials.

SECTION 3: INFORMATION ON COMPOUND OR SUBSTANCE

3.1 Mixture

Description Portland cement-clinker

Contents (% by weight)

EINECS 266-043-4

CAS 65997-15-1

Directive 1272/2008/EEC

Skin irritation Skin Irrit. 2

Severe eye impairment Eye Dam. 1

Skin irritability Skin Sens. 1

Toxicity on target organ – single exposure STOT SE 3

H315, H317, H318, H335

SECTION 4: FIRST AID MEASURES

4.1 First aid measures

General information

In case of contact with eyesDo not rub eye, should be rinsed with open eyelids under running water for at least 45 minutes. If possible,use isotonic eye wash (0.9% NaCl). Consult with your occupational health physician and/or eye specialist.

4/15

GHS07 GHS05

92-96%

Page 5: EN 197˜1 ˜ CEM I 52,5 R - LAFARGE

In case of skin contactDry cement powder must to be removed, then rinse thoroughly with water. In case of contact with wet cement the skin should be washed withplenty of water. Contaminated clothing, shoes, watch, etc. should be removed and thoroughly cleaned before next use.If symptoms appear (irritation), contact your doctor.

In case of inhalationGo to fresh air, breathe heavily to release dust from respiratory system as soon as possible.If symptoms appear (nausea, coughing, permanent irritation), contact your doctor.

After ingestionDo not make the injured person puke! If conscious, rinse mouth thoroughly and sip plenty of water, contact your doctor or the toxicologyinformation centre for help.

EyesCement (both dry and wet) may cause serious and permanent damage in case of contact with eyes.

Skin Prolonged contact with cement is irritating to the wet skin (due to sweating or humidity).Contact with wet skin may cause irritation, and might lead to dermatitis or severe skin lesions.For more information see (1).

InhalationRepeated and continuous inhalation over a longer period of time increases the risk of lung disease.

Environment Cement is environment friendly if used properly.

4.3 Indication in case of medical emergency or special treatmentTake this safety data sheet with you if contacting your doctor.

SECTION 5:FIRE SAFETY MEASURES

5.1 Fire extinguishing agents

Unsuitable extinguishing agents for safety reasons: none.

5.2 Special hazards derived from the substance or mixtureNot available.

SECTION 6:EMERGENCY MEASURES IN CASE OF ACCIDENTAL EXPOSURE

6.1 Personal precautionary measures, protective equipment and emergency proceduresWear protective clothing (see 8.2). Consider section 7.1 regarding safety procedures. Emergency management plan not required.

6.1.1. Non-emergency personnelWear protective clothing as described in Section 8. Follow the instructions regarding safety procedures as described in Section 7.

6.1.2. Rescue teamContingency plan not required. In case of high exposure to cement dust breathing apparatus must be worn.

6.2 Environmental precautionsAvoid contamination of draining system, surface water or groundwater.

5/15

Page 6: EN 197˜1 ˜ CEM I 52,5 R - LAFARGE

6.3 Measures and materials for containment and cleaningSpillage should be cleaned up using dry methods.

Dry cement

and HEPA), or make it wet and remove applying wet cement techniques.

Wet cementWet cement should be removed mechanically, wait until it sets and hardens on a plastic foil or in a special container and dispose as described in Section 13.

6.4 Reference to Sections7., 8. and 13. for further information.

SECTION 7:HANDLING AND STORAGE

7.1 Precautions for safe handlingCannot be stored or used around food, beverages or tobacco products.Additionally, the regulations of Section 8 must be followed. Avoid formation of dust. In case of bagged product or open mixing equipment always

clean-up methods for spillage. Lifting cement bags may increase muscle rigidity, and may lead to muscle strain in your lower back, arms, shoulders and legs. Be careful at all times, lift in an adequate and suitable manner.

7.2 Conditions for safe storageStore in the original package.Bulk cement should be stored in a silo, which is dry (internal condensation to be minimized), waterproof, clean and protected against dirt.Entering a place used for bulk cement storage, like a silo, a tanker truck or other container without adequate safety preparations is prohibited,

Checking of water soluble chromium (VI) content:

is a best before date indicated on the cement bags / delivery documents. Until this date, the water soluble chromium (VI) content remains under 0.0002% (in accordance with the provisions of the REACH Regulation). The manufacturer’s instructions for storage must be observed. Inadequate (wet) or

SECTION 8:EXPOSURE CONTROLS / PERSONAL PROTECTION

8.1 Control parameters

Description Threshold limit Exposure Frequency Note

Water soluble chromium (VI) 2 ppm Skin contactShort term (acute)

long term (repetitive)1907/2006/EC

Portland cement (powder) 10 mg/m3 Inhalation 8 hOn the basis of Annex 1 of

joint RegulationACGIH TLV 25/2000. (IX. 30.)

8.2 Exposure restrictions and control

8.2.1. Technical inspection

Measures to prevent dust formation or spreading, like the use of appropriate ventilation systems andcleaning methods which prevent dusting.

6/15

Page 7: EN 197˜1 ˜ CEM I 52,5 R - LAFARGE

UsePROC

Exposure Localised controls

Industrial manufacture/ formulation of hydraulic building and construction materials

2, 3

Dura

tion i

s not

restr

icted

(up t

o 480

minu

tes p

er sh

ift, 5

shift

s a w

eek)

Not required -

14, 26 A) not required or B) generic local exhaust ventilation

-

78%

5, 8b, 9 A) general ventilation or B) generic local exhaust ventilation

17%

78%

Industrial uses of dry hydraulic building and construction materials (indoor, outdoor)

2 Not required -

14, 22, 26 A) not required or B) generic local exhaust ventilation

-

78%

5,8b, 9 A) general ventilation or B) generic local exhaust ventilation

17%

78%

Industrial uses of wet suspension of hydraulic building and construction materials

2, 5, 8b, 9, 10, 13, 14 Not required -

7 A) not required or B) generic local exhaust ventilation

-

78%

Professional use of dry hydraulic building and construction material (indoor, outdoor)

2 Not required -

9, 26 A) not required or B) generic local exhaust ventilation

-

78%

5, 8a, 8b, 14 A) not required or B) integrated local exhaust ventilation

-

87%

19 Localised controls are not applicable, process only in good ventilated rooms or outdoor

50%

Professional uses of wet suspensions of hydraulic building and construction materials

11 A) not required or B) generic local exhaust ventilation

-

78%

2, 5, 8a, 8b, 9, 10, 13, 14, 19 Not required -

protective equipment. Only combinations between A) – A) and B) – B) are possible.

7/15

Page 8: EN 197˜1 ˜ CEM I 52,5 R - LAFARGE

8.2.2 Personal precautions, personal protective equipment

General safety and hygiene recommendations:

Avoid skin and eye contact. If possible, do not stand / kneel in fresh concrete or mortar during processing.

If necessary, wearing of alkaline resistant, waterproof protective clothing (e.g. Type C TYCHEM protective clothingcomplying with standards EN 368, EN 369, EN 463, EN 468, EN 1073-2 and EN 14126). Waterlogged or soiledclothing should be replaces immediately.

Eating, drinking or smoking is prohibited during work.

Hands should be washed during breaks and after work, and taking a shower in order to remove the adhering cement ishighly recommended. Contaminated clothing, footwear, watches, etc. to be cleaned before re-use.

Respiratory protection (S22 Do not breathe dust):

FFP-1 respirator complying with standard EN 149:2002 or 3M Half Facepiece reusable respirator equipped with 3M

Eye protection (S25 Avoid contact with eyes):

(complying with standard EN 166).

Skin protection (S24 Avoid contact with skin):

Wear waterproof, alkaline resistant gloves (complying with standards AQL 1,5 EN 374, EN 420:2003). Wear closedprotective clothing and closed footwear. Make sure, that you keep fresh mortar or concrete out of your shoes or boots.Using skincare after work is highly recommended.

8/15

Page 9: EN 197˜1 ˜ CEM I 52,5 R - LAFARGE

UsePROC

Exposure respiratory protective equipment (RPE)

assigned protection factor

(APF)

Industrial manufacture/ formulation of hydraulic building and construction materials

2, 3

Dura

tion i

s not

restr

icted

(up t

o 480

minu

tes p

er sh

ift, 5

shift

s a w

eek)

Not required -

14, 26 A) P1 mask (FF, FM) or B) not required

APF = 4

-

5, 8b, 9 A) P2 mask (FF, FM) or B) P1 mask (FF, FM)

APF = 10

APF = 4

Industrial uses of dry hydraulic building and construction materials (indoor, outdoor)

2 Not required -

14, 22, 26 A) P1 mask (FF, FM) or B) not required

APF = 4

-

5, 8b, 9 A) P2 mask (FF, FM) or B) P1 mask (FF, FM)

APF = 10

APF = 4

Industrial uses of wet suspension of hydraulic building and construction materials

2, 5, 8b, 9, 10, 13, 14 Not required -

7 A) P1 mask (FF, FM) or B) not required

APF = 4

-

Professional use of dry hydraulic building and construction material (indoor, outdoor)

2 P1 mask (FF, FM) APF = 4

9, 26 A) P2 mask (FF, FM) or B) P1 mask (FF, FM)

APF = 10

APF = 4

5, 8a, 8b, 14 A) P3 mask (FF, FM) or B) P1 mask (FF, FM)

APF = 20

APF = 4

19 P2 mask (FF, FM) APF = 10

Professional uses of wet suspensions of hydraulic building and construction materials

11 A) P2 mask (FF, FM) or B) P1 mask (FF, FM)

APF = 10

APF = 4

2, 5, 8a, 8b, 9, 10, 13, 14, 19 Not required -

protective equipment.

due to the breathing resistance and mass of the RPE itself, due to the increased thermal stress by enclosing the head. In addition, it shall be considered that the worker’s capability of using tools and of communicating are reduced during the wearing of RPE. For reasons as given above, the worker should therefore be (i) healthy (especially

The employer and self-employed persons have legal responsibilities for the maintenance and issue of respiratory protective devices and the management of their correct

8.3 Environmental exposure controls

Emissions from the work process equipment should be checked to ensure compliance with environmental regulations. Technical

9/15

Page 10: EN 197˜1 ˜ CEM I 52,5 R - LAFARGE

SECTION 9:PHYSICAL AND CHEMICAL PARAMETERS

9.1 Information on basic physical and chemical characteristics

Appearance / form

Odour Odourless

Odour threshold None, because odourless

pH (at T=20°C in water , water-solid ratio 1:2 ) 11 to 13.5

Meeting point > 1250 °C

Boiling point or boiling range Not applicable because its meeting point is about 1250°C

Flash point Not applicable, since not liquid

Evaporation rate Not applicable, since not liquid

Flammability (solid, gas)

Not applicable, since not gaseous

Vapour pressure Not applicable, since melting point >1250°C

Vapour density Not applicable, since melting point >1250°C

Relative density Density: 2.75-3.20 g/cm³; bulk density: 0.9-1.5 g/cm³

Solubility in water (T=20°C) Low (0.1-1.5 g / l)

Not applicable, since inorganic substance

Auto-ignition temperature Not applicable (not self-igniting, not organometallic compound)

Decomposition temperature Not applicable, since does not contain inorganic peroxides

Viscosity Not applicable, since not liquid

Explosion characteristicsNot explosive, non-pyrotechnic product, no gas emission or self-sustaining exothermicchemical reaction

Oxidizing characteristics Not applicable, cement has no oxidizing characteristics

9.2 Other characteristicsNot applicable.

SECTION 10:STABILITY AND REACTIVITY

10.1 ReactivityIf properly mixed with water, cement hardens and forms a solid material that does not react with the environment.

10.2 Chemical stabilityDry cement is stable, as long as properly stored (Section 7).

10.3 Possibility of hazardous reactionsNot applicable.

10.4 Circumstances to avoidMoisture during storage may cause caking and quality loss.

10.5 Incompatible materialsUncontrolled use of aluminium in wet cement should be avoided, since it results in hydrogen emission.

10.6 Hazardous decomposition productsNo known dangerous decomposition products.

10/15

Page 11: EN 197˜1 ˜ CEM I 52,5 R - LAFARGE

SECTION 11:TOXICOLOGICAL DATA

Hazard rate Category Reference

Acute toxicity – skin -Threshold limit test, rabbit, 24 hours, 2000mg/kg weight – no lethality.

(2)

Acute toxicity – inhalation -Threshold limit test, rat, 5g/m3 – no acute toxicity.The study was made using portland cement clinker, the main component of cement. (4)

Acute toxicity – ingestion -No acute oral toxicity experienced during animal studies.

Literature

Skin irritation/skin damage

2

The cement is skin- and mucous membrane irritant. Dry cement contacting wet skin, or skin

damage.

(2) and humanexperience

also

Severity of eye damage/skin irritation

1

In vitro studies showed that the Portland cement clinker (main component of cement) has (5), (6) and humanexperience

also

Skin sensibility 1

Contact with wet cement may cause eczema for some people. These cases might be caused by pH level (irritant contact dermatitis) or by immunological reactions from water soluble chromium (VI)

dermatitis, which can be derived from the combination of the two mechanisms. Accurate diagnosis

0.0002% using suitable reducing agent. There should be no increased sensibility as long as the best before date of the chromium reducing agent has not been exceeded.

(3), (7)

Sensibility of the respiratory system

- No signs of over-sensibility in the respiratory system caused by cement. (1)

Germ cell mutagenicity - (8), (9)

Carcinogenesis -

No causal relationship found between cement and cancer. Epidemiological studies indicateno link between cancer and exposure to cement. Portland cement is not considered to be ahuman carcinogen according to ACGIH A4. In vitro studies and animal tests do not provide (1), (10)

Reproductive toxicity -No evidence

based on humanexperience

toxicity in case ofsingle exposure

3

Exposure to cement dust may lead to irritation of the respiratory tract (mouth, throat, lungs). Meeting or exceeding the occupational exposure limit may result in coughing, wheezing, and shortness of breath. Long term occupational exposure may damage the respiratory system. However there is no

(1)

toxicity in case ofrepetitive exposure

-Exceeding the occupational exposure limit may result in coughing, shortness of breath and

(11)

Aspiration - Not relevant, not present as aerosol.

Inhalation of cement may intensify existing respiratory disease, for example asthma or pulmonary emphysema.

11/15

Page 12: EN 197˜1 ˜ CEM I 52,5 R - LAFARGE

SECTION 12:ECOLOGICAL INFORMATION

12.1 ToxicityThis product does not threaten the environment. Bio-toxicological analysis of Portland cement using Daphnia magna (U.S. EPA, 1994a) (12) and

12.2 Persistence and degradabilityNot applicable, as cement is an inorganic mineral product. After hydration the cement residues do not represent a toxicological risk.

12.3 Bioaccumulative capabilityNot applicable, as it is an inorganic mineral product.

12.4 Mobility in soilNot applicable, as cement is an inorganic mineral product. After hydration the cement residues do not represent a toxicological risk.

12.5 Results of the PBT and vPvB assessmentNot applicable, as cement is an inorganic mineral product. After hydration the cement residues do not represent a toxicological risk.

Not applicable.

SECTION 13:DISPOSAL CONSIDERATIONS

13.1 Waste management systems

13.1.1. Expired products containing reducing agent, if water soluble chromium (VI) content exceeds 0.0002%The product cannot be marketed or used, except in the case where a controlled, closed, and fully automated technology is used, or chromiumreducing agent is added.

13.1.2. Remaining unused dry productGather dry product. Select container. Use it before the expiry date keeping in mind to avoid making dust. In case of disposal, add water and waituntil it becomes solid, and then proceed with waste management as described in section 13.1.4.

13.1.3. Wet, silty productLet the wet, muddy product to become solid, keeping in mind to avoid leakage to sewage system or surrounding waters. Disposal as described in section 13.1.4.

13.1.4. If hardened after water addedTo be treated as waste. Do not dispose to sewage system. It becomes solid after 5 to 6 hours and can be treated as concrete waste or concrete silt.

13.1.5. Contaminated packagingPackaging should be emptied completely and recycled.

SECTION 14:TRANSPORT INFORMATION

Cement is not subject to international regulations on the transport of hazardous materials (IMDG, IATA, ADR / RID). Therefore no respective

14.1 UN numberNot applicable.

14.2 Proper shipping name for UNNot applicable.

14.3 Transport hazard classNot applicable.

12/15

Page 13: EN 197˜1 ˜ CEM I 52,5 R - LAFARGE

- �rst version

Page 14: EN 197˜1 ˜ CEM I 52,5 R - LAFARGE
Page 15: EN 197˜1 ˜ CEM I 52,5 R - LAFARGE