ILLUMINATOR LV Emergency Lighting Inverter System 175VA through 750VA ILLUMINATOR LV Emergency Lighting Inverter System 175VA through 750VA Illuminator Series LV Single Phase

Transcript of Emergency Lighting Inverter System 175VA through 750VAmyerspowerproducts.com/literature/Illuminator...

Page 1: Emergency Lighting Inverter System 175VA through 750VAmyerspowerproducts.com/literature/Illuminator LV - Catalog_web.pdfinverter is compliant with UL924 self-testing standards as well

ILLUMINATOR LVEmergency Lighting Inverter System

175VA through 750VA

ILLUMINATOR LVEmergency Lighting Inverter System

175VA through 750VA

Illuminator Series LVSingle Phase

Page 2: Emergency Lighting Inverter System 175VA through 750VAmyerspowerproducts.com/literature/Illuminator LV - Catalog_web.pdfinverter is compliant with UL924 self-testing standards as well

Photos 2

ILLUMINATOR SERIES LV

1

STANDARD VERSUS ADVANCED SYSTEM CODE COMPLIANCE

The Illuminator Series LV is a 175VA-750VA fast transfer Emergency Lighting Inverter utilizing Myers Power Products advanced technology. The Illuminator LV is designed to support the needs of smaller facilities and those now utilizing LED lighting technology. This system meets all requirements of UL924 including self-testing and is listed by UL (Underwriters Laboratories). In addition, the optional meter panel feature of this system will allow the end user to meet the advanced testing & logging requirements as defi ned by NFPA101. The ability to support any lighting source including, but not limited to LED, Fluorescent, and HID enhances the ability of the end user to design the space for the fi t, form, and function they desire. The Illuminator LV (as well as all of the Myers Power Products family of Emergency Lighting Inverters) is designed so that any light fi xture that is appropriate for your facility can be chosen and used for both normal and emergency lighting. This means that the architectural features and design of a space do not have to be compromised by the use of additional types of fi xtures added solely to meet the emergency lighting requirements.

The Illuminator Series LV design is highly effi cient, minimizing the overall operating costs of your emergency lighting system. The design utilizes fast transfer technology which is an offl ine 2mS transfer system; able to support all lamp sources, the of-fl ine system is extremely reliable and effi cient making it exceptionally economical to own and operate.

With a substantially smaller footprint, this unit is available in 4 distinct capacities (175W, 350W, 550W, and 750W) and can be either wall or fl oor mounted. In addition, the 175 watt system is available in an optional ceiling grid mounted version where it is designed to be plenum rated. See page 5 for dimensions or visit our website at www.myerspowerproducts.com.

Advanced Systems: The advanced (Model Type 2 and 3) LV Series inverter is compliant with UL924 self-testing standards as well as NFPA101 self-testing standards. This system comes complete with a programmable meter panel (system mounted, remote mounted or handheld). This system performs a 5 minute runtime test 11 times a year and, a 90 minute runtime test 1 time a year. The dates and times of these tests are fully programmable by the end user. This system captures the last 25 tests in its internal test log. In addition to the advanced testing functions, this system allows complete access to a wide variety of data regarding the status of the system through the meter panel.

Standard Systems: Myers standard (Model Type 1) LV Series invert-er is compliant with UL924 self-testing standards. It is provided with a self-test feature that runs a test every 28 days and one extended yearly runtime test. This test is not programmable and is controlled by an internal clock embedded in the system electronics. After a successful completion of either of these tests the systems will indicate as such by illuminating the Ready LED indicator light. If a failure of either of these tests occurs, the Ready LED indicator will fl ash. There is no record or log of these tests. A complete list of functions is available in the Metering Manual on Myers’ website at www.myerspowerproducts.com.

Testing Metering Data Logging Alarms

Standard Model Type 1 UL924 Self-Testing/Self-Diagnostic

not available not available Visual

Advanced Model Type 2 and 3 UL924 Self-Testing/Self-Diagnostic

NFPA101 Self-Testing/Self-Diagnostic

System mounted, remote mounted,

or hand-held

Alarm log, event log, test log

Audible andVisual

Photos 2

Page 3: Emergency Lighting Inverter System 175VA through 750VAmyerspowerproducts.com/literature/Illuminator LV - Catalog_web.pdfinverter is compliant with UL924 self-testing standards as well

STANDARD SYSTEM DESIGN FEATURES

2

ADVANCED SYSTEM DESIGN FEATURES

• PWM/MOSFET pure sine wave inverter technology• Microprocessor controlled• 90 minute runtime• High effi ciency; no fans required• UL 924 listed• UL 924 self-testing and self-diagnostic• Field selectable voltage; 120 volt input/output or

277 volt input/output• Compatible with all light sources including LED, HID,

Fluorescent, Incandescent, Quartz and Electronic Low Voltage Lighting

• High Crest Factor inrush capabilities• Red Wall Mounted cabinet (other mounting options and colors

available; see ordering guide page 4)• Maintenance free VRLA batteries• System Status indicators and momentary test switch• Input fuse and battery fuse protection• Summary Alarm Form C dry contacts• Available outputs: normally on and 1 normally off or switched

output• Normally off has an available 15 minute time delay• Output circuit breakers are available for 350, 550 and 750W

models• Alarms include monthly test fault, yearly test fault, charger fault,

load reduction fault, output voltage low, output voltage high, overload fault, low voltage disconnect, heatsink over temp and input fuse failure

• NFPA 101 self-testing, self-diagnostic, and logging• OLED display system mounted meter panel provides access to

systems logs and programming (Remote and handheld options available). See page 4 of the ordering guide

• Control panel has an easy to use 4-button keypad which is used to access all information

• Metering function and system status allows access to a multitude of data regarding the electrical characteristics of the system including input voltage, input current, input frequency, output voltage, output current, output power, battery voltage, battery current, battery temperature, battery power, internal ambient temperature, heat sink temperature, UPS events, UPS time and system days online

• System setup allows the user to set parameters and customize settings that can indicate out of tolerance conditions

• Monthly and yearly tests can be programmed by the user to meet the date and time requirements of the facility

• In addition to basic alarms, advanced alarms include: input frequency low, input frequency high, input voltage low, input voltage high, output voltage low, output voltage high, battery voltage low, battery voltage high, battery temp low, battery temp high, ambient temp low, ambient temp high, and on inverter timer

Page 4: Emergency Lighting Inverter System 175VA through 750VAmyerspowerproducts.com/literature/Illuminator LV - Catalog_web.pdfinverter is compliant with UL924 self-testing standards as well

ADVANCED SYSTEM OPTIONS

PROGRAMMABLE INPUT / OUTPUT OPTIONS

VARIABLE TIME DELAYAllows for programmable delay of inverter retransfer to continue supplying emergency power to the normally off output for up to 15 minutes after the return of power

OUTPUT CIRCUIT BREAKERSMaximum output breakers available: 750 watt system 6 total, 350/550 watt system 3 total, 175 watt system 0 available. Normally on, normally off, and switched options available

BACNETAllows for communications of data from the inverter using BACnet protocol. Myers’ user configurable system is a full MS/TP master slave device

USB MASS STORAGEProvides additional storage capabilities for up to 3000 alarms and 60 test logs. USB option allows for system logs to be copied to USB flash drive for import to data management program (software included). This option expands the capabilities of internal data and alarm logging

METERING PANELSAvailable in three configurations: System mounted, Remote mounted, and Handheld

FAST CHARGEA battery charger upgrade which decreases the time to recharge a fully discharged battery bank to a full charge. The recharge time is decreased from the standard 24-hour period to a 12-hour period

MOUNTINGWall mount (standard); optional recessed wall mount and plenum rated grid mount (175 watt only) and floor mount (350/550/750)

STATUS MONITORING CONTACTS (FACTORY PRESET TO LISTED ALARMS (Option “C”))AC Present, Inverter On/Off, Test Failure, System Overload, Near Low Batery, Blown Fuse Indicator

AVAILABLE STATUS MONITORING CONTACTS (6 MAXIMUM IN SYSTEM WITHOUT SWITCHED OUTPUT)On Battery, Charger Failure, Overcurrent, AC Present, Monthly/Yearly test failure, Load reduction alarm, System overload, Input voltage high/low, Output current, High ambient temperature, High battery temperature, Inverter ON/OFF, Near low battery, Blown fuse indicator

SWITCHED OUTPUT CIRCUIT BREAKERSUp to 3 separate switched 10 amp output circuit breakers. The number of switched outputs will reduce available contact relays (see chart on page 4)

ZONE MONITORING (Option “Z”)Monitors AC power presence in a specific zone (area, distribution panel, etc.). Upon loss of power in the zone(s), the inverter will turn on, activating all normally off (emergency only) circuits. All normally on loads will remain on. When primary power returns in the zone(s), inverter will turn off after its preset delay and normally off loads will turn off. Consult factory for quantity limits per application.

3

Page 5: Emergency Lighting Inverter System 175VA through 750VAmyerspowerproducts.com/literature/Illuminator LV - Catalog_web.pdfinverter is compliant with UL924 self-testing standards as well

ORDERING GUIDE

- Standard (UL924)- Internal Meter Panel and Advanced Testing & Logging (UL924 & NFPA101)- Advanced Testing & Logging (UL924 & NFPA101)

LV - Illuminator Series “LV”ACCESSORIESOUTPUT BREAKERSHH

RMP X B

5, 10, 15, 20

1-6 6

ENCLOSURE COLOR81

2

5, 7

7

3, 10

3

VA/W

9

1 2 3 4

Wall Mounted Unit is StandardVA=WNormally o� not available when using switched outputRequires Model Type 3Requires HH or RMP option to retrieve data175W OCB’s not available, 350/550W 3 OCB’s max, 750W 6 OCB’s maxNo meter panel includedGrid mounted system standard color is whiteAll other models, standard color is redOptional colors availableInternal meter panel is not available with grid mount cabinetMaximum of 3 switched outputs, each with 10 amp circuit breaker on Type 2 & 3 systems, only 1 switched output is available on Type1 systemMultiple switched outputs limit available alarm contacts (see chart below)Requires Model Type 2 or 3 OptionsNot available with options "C","Z" or systems with more than 1 switched outputNot available with options "H","Z" or systems with more than 1 switched output

12

3

B 20 03Example:

N S

- Floor Mount (not available on 175 watt)- Status Monitoring Contacts (see chart below)- NEMA 2R Drip Top- Fast Charge Option- Grid Mount (175 watt only)- BACnet - Infrared Remote Test- Battery Strapping- USB Mass storage- Recessed wall mount (175 watt only)- Zone Monitoring

8, 9

12

12, 13

12

12

12, 14

6 4

- 175- 350- 550- 750

RWGB

- Red (Standard)- White- Grey- Black

- None- Normally On- Normally Off- Switched

- Handheld Meter Panel (one HH can be used for multiple units)- Remote Meter Panel (1 per system) (requires model type 3)

LV-2-R-2-B2003-F-HHExample Model Number

SYSTEM TYPE

LV 2 R 2 B 20 03 F HH

OUTPUT

AMP RATING

QUANTITY

OPTIONSMODEL TYPE

1.2.3.4.5.6.7.8.

9.10.

11.12.13.14.

BC

DFGHRSUWZ

4

Output Circuit Breaker Available Configurations for 350/550/750 VA systems

Quantity of available Form C contacts

Zone Monitor inputs available

Status Monitoring Option "C"

BXX01 6 0 Available

BXX01 3 3 Not Available

BXX02 6 0 Available

BXX02 3 3 Not Available

BXX03 6 0 Available

BXX03 3 3 Not Available

S1001 2 2 Not Available

S1001 6 0 Available

S1001-BXX01 2 2 Not Available

S1001-BXX01 6 0 Available

S1001-BXX02 2 2 Not Available

S1001-BXX02 6 0 Available

S1002 1 1 Not Available

S1002-BXX01 1 1 Not Available

S1003 0 0 Not Available

XX = Breaker amperage (5,10,15 or 20A Available)B = Normally On breaker S= Switched Output circuit breaker(s) (10A Breaker only available). 750 VA system, 3 additional Normally On Output Circuit Breakers are availableIf Normally Off Breakers are required contact factory for assistance

AVAILABLE OUTPUT CIRCUIT BREAKER AND OPTIONS CONFIGURATIONS

Page 6: Emergency Lighting Inverter System 175VA through 750VAmyerspowerproducts.com/literature/Illuminator LV - Catalog_web.pdfinverter is compliant with UL924 self-testing standards as well

SYSTEM SPECIFICATIONS

19”9.25”

22”

25.25”9.25”

22”

14.25”6.5”

17.75”

LV-1 175 92% 45 41 14.25/36.20 6.50/16.51 17.75/45.09 30/13.62 25/11.35 1 1 12 17 55/24.97

LV1G 175 92% 45 41 23.84/60.55 8/20. 32 7.5/19.05 30/13.62 25/11.35 1 1 12 17 55/24.97

LV-2 350 96% 45 48 19/48.26 9.25/23.50 22/55.88 50/22.7 50/22.7 2 24 17 100/45.4

LV-3 550 97% 45 56 19/48.26 9.25/23.50 22/55.88 55/24.97 75/34.05 3 3 36 17 130/59.02

LV-4 750 97% 45 64 25.25/64.14 9.25/23.50 22/55.88 80/36.32 100/45.4 4 4 48 17 180/81.72

Base Model

Power Rating (VA/W)

Efficiency (@ full load)

Audible Noise (dB a @1m

Heat Loss (BTU)/HR

Cabinet Dimensions

Width in/cm

Depthin/cm

Heightin/cm

Weightlbs/kg

90 Minute Batteries lbs/kg

Total System Weight lbs/kg

Number of Batteries

BATTERIES(90 Minutes @ Full Load)

ELECTRONICS MODULE

Voltage (VDC)

Current (amps)

5

ILLUMINATOR LV-1

ILLUMINATOR LV-2 & LV-3

ILLUMINATOR LV-4ILLUMINATOR LV-1G

23.84”

Height 7.5”

8”

Page 7: Emergency Lighting Inverter System 175VA through 750VAmyerspowerproducts.com/literature/Illuminator LV - Catalog_web.pdfinverter is compliant with UL924 self-testing standards as well

SYSTEM SPECIFICATIONS

VoltageInput Frequency

Synchronizing Slew RateProtection

Harmonic Distortion

120 or 277Vac 1-phase 2-wire +10% -15%60Hz, +/-3%1 Hz per second nominalFuse< 10% (For Resistive Load)

VoltageStatic Voltage

Dynamic VoltageHarmonic Distortion

OverloadOutput Frequency

Load Power FactorInverter Overload

Output TypesProtection

Crest Factor

120 or 277Vac 1-phase 2-wireLoad current change +/- 2%, battery discharge +/- 12.5%+/- 10% for load step change, recovery within 5 cycles< 3% THD for linear loadCircuit Breaker protected (Optional)60Hz +/- .05 Hz during emergency mode.5 lag to .5 lead250% for 16 Cycles, 110% continuouslyNormally On, Normally Off or SwitchedOptional Distribution Circuit Breaker(s) (350, 550 and 750W)3.5

TypeCharger

Protection

Disconnect

Valve-regulated sealed lead-calciumMicrocontroller, 3-stage charger (recharge per UL-924 Specifications)Automatic low battery disconnect; automatic restart upon utility returnFuse

Altitude

Operating Temperature

Storage TemperatureRelative Humidity

< 10,000 feel (above sea level) without deratingInverter: 0° to 40° C (32° to 104° F)Battery: 20° to 30° C (68° to 86° F) per UL-924-20° to 70° C (-40° to 158° F) (electronics only)< 95% (non-condensing)

Design

Generator InputIndicator Lights & Switch

Optional Control Panel

Optional Metering

Standard Alarms

Alarm ContactsWarranty

Optional Warranties

Line interactive PWM inverter type utilizing MOSFET technology with 2mS transfer timeCompatible with generators. (25KVA or larger)Charging. Ready, Inverter and Test switchOLED display with key pad controls/functions & scrolling system statusInput & Output Voltage, Battery Voltage, Battery & Output Current, Output VA, Input Current, Inverter WattageAmbient/Battery/Heatsink Temperature, Input Frequency, UPS Time & Events, Days of OperationMonthly Test Fault, Yearly Test fault, Charger Fault, Load Reduction Fault, Output Voltage Low, Output Voltage High, Overload Fault, Low Voltage Disconnect,Heatsink Overtemp and Input Fuse FailureInput Frequency Low, Input Frequency High, Input Voltage Low, Input Voltage High, Output Voltage Low, Output Voltage High, Battery Voltage Low, Battery Voltage High, Battery Temp Low, Battery Temp High, Ambient Temp Low, Ambient Temp High and On Iinverter Timer Summary Fault Form “C”3 year standard warranty includes all parts; 10 years prorated warranty on batteriesExtended warranties, Preventative Maintenance and/or Customized Service Plans.

CabinetCooling

Cable EntryAccess

Wall Mount; Recess or T-Grid available only on 175W systemConvection CooledTop or SideFront

Input

General

Physical

Output

Battery

Environmental

Optional Alarms

6

Page 8: Emergency Lighting Inverter System 175VA through 750VAmyerspowerproducts.com/literature/Illuminator LV - Catalog_web.pdfinverter is compliant with UL924 self-testing standards as well

44 South Commerce Way • Bethlehem, PA 18017Tel: (800) 526-5088 • Fax: (610) 868-8686

www.myerspowerproducts.com

03-2

3-20

16

Illuminator Series E/IESingle Phase

1.5KVA to 16.7KVA

Illuminator Series EM Single Phase

1KVA to 2.8KVA

Illuminator Series CR/DRSingle and Three Phase

Outdoor System 3KVA to 8KVA

Illuminator Series CIIIThree Phase

4.8KVA to 50KVA