Shenzhen Global Test Service Co.,Ltd. No.7-101 and 8A-104, Building 7 and 8, DCC Cultural and Creative Garden, No.98, Pingxin North Road, Shangmugu Community, Pinghu Street, Longgang District, Shenzhen, Guangdong TEST REPORT J 55014-1 (H27) Electromagnetic compatibility – Requirements for household appliances, electric tools and similar apparatus. Part 1: Emission Report Reference No. ..................... : GTS20200417009-1-1 Reviewed by (Testing Engineer) ............................ : Jerry Wang Approved by (Manager) ......................................... : Simon Hu Date of issue..................................... : Apr. 24, 2020 Testing Laboratory Name .............. : Shenzhen Global Test Service Co., Ltd. Address............................................. : No.7-101 and 8A-104, Building 7 and 8, DCC Cultural and Creative Garden, No.98, Pingxin North Road, Shangmugu Community, Pinghu Street, Longgang District, Shenzhen, Guangdong Applicant’s name ............................ : Dong Guan PuTian Metal Product Co., Ltd Address............................................. : No.2 Wai Jing Industry District Chi Gang Community, Hu Men Town Dong Guan City Guang Dong Province Test specification: Standard ........................................... : J 55014-1 (H27) TRF Originator .................................. : Shenzhen Global Test Service Co.,Ltd. Master TRF ....................................... : Dated 2014-12 Shenzhen Global Test Service Co.,Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen Global Test Service Co.,Ltd. is acknowledged as copyright owner and source of the material. Shenzhen Global Test Service Co.,Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description .................... : Sweeping robot Trade Mark ....................................... : / Manufacturer .................................. : Dong Guan PuTian Metal Product Co., Ltd Model/Type reference....................... : A550 Listed Models .................................. : A551 Ratings.............................................. : Input:100 V-240V~50/60 Hz;0.5A Max Output: 19 V 0.6 A Battery parameters:DC 14.4 V; 30 W Result................................................ : Pass

Transcript of EMC TRF Template - m.media-amazon.com

Page 1: EMC TRF Template - m.media-amazon.com

Shenzhen Global Test Service Co.,Ltd. No.7-101 and 8A-104, Building 7 and 8, DCC Cultural and Creative Garden, No.98, Pingxin North Road, Shangmugu Community, Pinghu Street, Longgang District, Shenzhen, Guangdong

TEST REPORT J 55014-1 (H27)

Electromagnetic compatibility – Requirements for household appliances, electric tools and similar apparatus. Part 1: Emission

Report Reference No. ..................... : GTS20200417009-1-1 Reviewed by (Testing Engineer) ............................ :

Jerry Wang

Approved by (Manager) ......................................... :

Simon Hu

Date of issue ..................................... : Apr. 24, 2020

Testing Laboratory Name .............. : Shenzhen Global Test Service Co., Ltd. Address ............................................. : No.7-101 and 8A-104, Building 7 and 8, DCC Cultural and Creative

Garden, No.98, Pingxin North Road, Shangmugu Community, Pinghu Street, Longgang District, Shenzhen, Guangdong

Applicant’s name ............................ : Dong Guan PuTian Metal Product Co., Ltd

Address ............................................. : No.2 Wai Jing Industry District Chi Gang Community, Hu Men Town Dong Guan City Guang Dong Province

Test specification:

Standard ........................................... : J 55014-1 (H27) TRF Originator .................................. : Shenzhen Global Test Service Co.,Ltd. Master TRF ....................................... : Dated 2014-12 Shenzhen Global Test Service Co.,Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen Global Test Service Co.,Ltd. is acknowledged as copyright owner and source of the material. Shenzhen Global Test Service Co.,Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description .................... : Sweeping robot

Trade Mark ....................................... : /

Manufacturer .................................. : Dong Guan PuTian Metal Product Co., Ltd

Model/Type reference ....................... : A550

Listed Models .................................. : A551 Ratings .............................................. : Input:100 V-240V~50/60 Hz;0.5A Max

Output: 19 V 0.6 A Battery parameters:DC 14.4 V; 30 W

Result ................................................ : Pass

Page 2: EMC TRF Template - m.media-amazon.com

Report No.: GTS20200417009-1-1 Page 2 of 16

EMC -- T E S T R E P O R T

Test Report No. : GTS20200417009-1-1 Apr. 24, 2020 ______________________________________________________________________________________________

Date of issue

Equipment under Test : sweeping robot

Model /Type : A550、A551

Applicant : Dong Guan PuTian Metal Product Co., Ltd

Address : No.2 Wai Jing Industry District Chi Gang Community, Hu Men Town Dong Guan City Guang Dong Province

Manufacturer : Dong Guan PuTian Metal Product Co., Ltd

Address : No.2 Wai Jing Industry District Chi Gang Community, Hu Men Town Dong Guan City Guang Dong Province

Test Result

PASS

The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory.

Page 3: EMC TRF Template - m.media-amazon.com

Report No.: GTS20200417009-1-1 Page 3 of 16

Contents 1 TEST STANDARDS ...................................................................................................................................... 4 2 SUMMARY .................................................................................................................................................... 5

2.1 GENERAL REMARKS ................................................................................................................................. 5 2.2 EQUIPMENT UNDER TEST ......................................................................................................................... 5 2.3 SHORT DESCRIPTION OF THE EQUIPMENT UNDER TEST (EUT) .................................................................... 5 2.4 EUT OPERATION MODE ............................................................................................................................. 5 2.5 EUT CONFIGURATION ............................................................................................................................... 5

3 TEST ENVIRONMENT .................................................................................................................................. 6 3.1 ADDRESS OF THE TEST LABORATORY ......................................................................................................... 6 3.2 TEST FACILITY .......................................................................................................................................... 6 3.3 ENVIRONMENTAL CONDITIONS ................................................................................................................... 6 3.4 TEST DESCRIPTION .................................................................................................................................. 7 3.5 STATEMENT OF THE MEASUREMENT UNCERTAINTY ..................................................................................... 7 3.6 EQUIPMENTS USED DURING THE TEST ....................................................................................................... 8

4 TEST CONDITIONS AND RESULTS ........................................................................................................... 9 4.1 CONDUCTED DISTURBANCE ....................................................................................................................... 9 4.2 DISTURBANCE POWER ............................................................................................................................ 12

5 TEST SETUP PHOTOS OF THE EUT ....................................................................................................... 15 6 EXTERNAL AND INTERNAL PHOTOS OF THE EUT .............................................................................. 16

6.1 EXTERNAL PHOTOS OF THE EUT ............................................................................................................. 16

Page 4: EMC TRF Template - m.media-amazon.com

Report No.: GTS20200417009-1-1 Page 4 of 16 1 T E S T S T A N D A R D S The tests were performed according to following standards: J 55014-1(H27) Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus -- Part 1: Emission

Page 5: EMC TRF Template - m.media-amazon.com

Report No.: GTS20200417009-1-1 Page 5 of 16 2 S U M M A R Y

2.1 General Remarks Date of receipt of test sample : Apr. 20, 2020 Testing commenced on : Apr. 20, 2020 Testing concluded on : Apr. 22, 2020

2.2 Equipment Under Test Power supply system utilised Power supply voltage : 120 V / 60 Hz ○ 230V / 50Hz ○ 12 V DC ○ 24 V DC ○ Other (specified in blank below)

2.3 Short description of the Equipment under Test (EUT) The EUT is a Sweeping robot

2.4 EUT operation mode Operation mode Mode 1 working Worst mode 1

2.5 EUT configuration The following peripheral devices and interface cables were connected during the measurement: o - supplied by the manufacturer - supplied by the lab o adapter M/N: CZH015190060JPWH Manufacturer: /

Page 6: EMC TRF Template - m.media-amazon.com

Report No.: GTS20200417009-1-1 Page 6 of 16 3 T E S T E N V I R O N M E N T

3.1 Address of the test laboratory

Shenzhen Global Test Service Co.,Ltd. No.7-101 and 8A-104, Building 7 and 8, DCC Cultural and Creative Garden, No.98, Pingxin North Road, Shangmugu Community, Pinghu Street, Longgang District, Shenzhen, Guangdong

3.2 Test Facility The test facility is recognized, certified, or accredited by the following organizations:

CNAS (No. CNAS L8169) Shenzhen Global Test Service Co., Ltd. has been assessed and proved to be in compliance with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC 17025: 2017 General Requirements) for the Competence of Testing and Calibration Laboratories. A2LA (Certificate No. 4758.01) Shenzhen Global Test Service Co., Ltd. has been assessed by the American Association for Laboratory Accreditation (A2LA). Certificate No. 4758.01.

3.3 Environmental conditions During the measurement the environmental conditions were within the listed ranges:

Temperature: 15-35 ° C Humidity: 30-60 % Atmospheric pressure: 950-1050mbar

Page 7: EMC TRF Template - m.media-amazon.com

Report No.: GTS20200417009-1-1 Page 7 of 16

3.4 Test Description Emission Measurement

Conducted Disturbance J 55014-1 (H27) PASS

Radiated Emission J 55014-1 (H27) N/A

Click Test J 55014-1 (H27) N/A

Power Clamp Radiation J 55014-1 (H27) PASS

Remark: N/A means “not applicable”. The measurement uncertainty is not included in the test result.

3.5 Statement of the measurement uncertainty The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report acc. to TR-100028-01” Electromagnetic compatibility and Radio spectrum Matters (ERM);Uncertainties in the measurement of mobile radio equipment characteristics; Part 1” and TR-100028-02 “Electromagnetic compatibility and Radio spectrum Matters (ERM);Uncertainties in the measurement of mobile radio equipment characteristics; Part 2 “ and is documented in the Shenzhen Global Test Service Co.,Ltd quality system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device. Hereafter the best measurement capability for Shenzhen GTS laboratory is reported:

Test

Range

Measurement Uncertainty

Notes

Conducted Disturbance 0.15~30MHz 3.12 (1) Power Clamp Radiation 30~300MHz 2.32 (1)

(1) This uncertainty represents an expanded uncertainty expressed at approximately the 95%

confidence level using a coverage factor of k=2.

Page 8: EMC TRF Template - m.media-amazon.com

Report No.: GTS20200417009-1-1 Page 8 of 16

3.6 Equipments Used during the Test

Conducted Disturbance

Item Test Equipment Manufacturer Model No. Serial No. Last Cal.

1 EMI Test Receiver ROHDE & SCHWARZ ESCI 101102 2019-09-20

2 Artificial Mains ROHDE & SCHWARZ ESH2-Z5 893606/008 2019-09-20

3 Pulse Limiter CYBERTEK EM5010A E1950100106 2019-09-20

Disturbance power

Item Test Equipment Manufacturer Model No. Serial No. Last Cal.

1 EMI Test Receiver ROHDE & SCHWARZ ESCI 101102 2019-09-20

2 Absorbing Clamp LÜTHI MDS-21 03389 2019-09-20 The calibration interval was one year.

Page 9: EMC TRF Template - m.media-amazon.com

Report No.: GTS20200417009-1-1 Page 9 of 16 4 T E S T C O N D I T I O N S A N D R E S U L T S

4.1 Conducted disturbance 4.1.1 LIMITS OF DISTURBANCE

Frequency Range (MHz) Limits (dBuV)

Quasi-Peak Average 0.150~0.500 66~56 59~46

0.500~5.000 56 46

5.000~30.000 60 50 Note: (1) The tighter limit shall apply at the edge between two frequency bands. 4.1.2 TEST CONFIGURATION

4.1.3 TEST PROCEDURE EUT is placed on a nonmetal table which is 0.8 meter (or 0.1 meter for floor-stood equipments) above the grounded reference plane. Connect the power line of the EUT to the LISN. Voltage of the power supply is varied over a range of 0.9 to 1.1 times of the rated voltage in order to check whether the level of disturbance varies considerably with the supply voltage at the selected frequency about 160KHz. Perform an initial measurement on each line with peak detector to identify the frequencies where the maximum disturbances may occur. Then measure and record the maximum disturbances with quasi-peak and average detector.

4.1.4 CLIMATIC CONDITIONS

ambient temperature : 25 ℃

relative humidity: 52%

atmospheric pressure: 960 mbar

4.1.5 TEST RESULTS

EUT LISN

RECEIVER

RGP

Page 10: EMC TRF Template - m.media-amazon.com

Report No.: GTS20200417009-1-1 Page 10 of 16

Test mode: Mode 1 Polarization L1

Page 11: EMC TRF Template - m.media-amazon.com

Report No.: GTS20200417009-1-1 Page 11 of 16

Test mode: Mode 1 Polarization N

Page 12: EMC TRF Template - m.media-amazon.com

Report No.: GTS20200417009-1-1 Page 12 of 16

4.2 Disturbance power 4.2.1 LIMITS OF DISTURBANCE

Frequency Range (MHz) Limits ( dBpW )

Quasi-Peak Average 30~300 45~55 35~45

Note: (1) The limit line is a linear line.

4.2.2 TEST CONFIGURATION

4.2.3 TEST PROCEDURE EUT is placed on a nonmetal table which is 0.8 meter (or 0.1 meter for floor-stood equipments) above the reference ground plane. The line under test is put through the absorbing clamp. Also, voltage of the power supply is varied over a range of 0.9 to 1.1 times of the rated voltage in order to check whether the level of disturbance varies considerably with the supply voltage at the selected frequency about 50MHz. Then the absorbing clamp can be remote-controlled to slide on the slidebar which is 6 meters long to determine the position of the maximum emission level. Other terminals of EUT are tested with the same steps described above.

4.2.4 CLIMATIC CONDITIONS

ambient temperature : 25 ℃

relative humidity: 52%

atmospheric pressure: 960 mbar

4.2.5 TEST RESULTS

Page 13: EMC TRF Template - m.media-amazon.com

Report No.: GTS20200417009-1-1 Page 13 of 16

Test mode: Mode 1 Polarization AC Line

Page 14: EMC TRF Template - m.media-amazon.com

Report No.: GTS20200417009-1-1 Page 14 of 16

Test mode: Mode 1 Polarization DC Line

Page 15: EMC TRF Template - m.media-amazon.com

Report No.: GTS20200417009-1-1 Page 15 of 16 5 T e s t S e t u p P h o t o s o f t h e E U T

Conducted Emission

Disturbance power

Page 16: EMC TRF Template - m.media-amazon.com

Report No.: GTS20200417009-1-1 Page 16 of 16 6 E x t e r n a l a n d I n t e r n a l P h o t o s o f t h e E U T 6.1 External photos of the EUT

......................End of Report.......................