General-Purpose AC Servo H EMC Installation Guidelines

Transcript of EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC...

Page 1: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

IB (NA) 67310-H (1512) MEE Printed in Japan Specifications are subject to change without notice. This Guidelines uses recycled paper.

MODEL

MODELCODE

General-Purpose AC Servo

H

EMC InstallationGuidelines

1CW950

EMC INSTRUCTION GUIDELINES

HEAD OFFICE : TOKYO BLDG MARUNOUCHI TOKYO 100-8310

Page 2: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

1

CONTENTS

1. SUMMARY 1 - 1 to 1 - 2

2. EMC DIRECTIVE 2 - 1 to 2 - 2

3. EMC COUNTERMEASURES 3 - 1 to 3 -10

3.1 Basic EMC countermeasures .................................................................................................................. 3 - 1

3.2 Cabinet design ......................................................................................................................................... 3 - 1

3.3 Filter wiring and installation ...................................................................................................................... 3 - 4

3.4 Cable treatment ........................................................................................................................................ 3 - 6

4. EMC COUNTERMEASURE PARTS 4 - 1 to 4 - 8

4.1 Noise filter (For controller power supply) ................................................................................................. 4 - 1

4.2 EMC filter (For servo amplifier power supply) ......................................................................................... 4 - 1

4.3 Ferrite core (Data line filter) ..................................................................................................................... 4 - 5

4.4 Shield clamp fitting ................................................................................................................................... 4 - 5

4.5 Line noise filter ......................................................................................................................................... 4 - 6

4.5.1 Connection example ......................................................................................................................... 4 - 6

4.5.2 Precautions ........................................................................................................................................ 4 - 7

4.6 Surge protector ......................................................................................................................................... 4 - 8

5. CONNECTION EXAMPLE FOR EMC COUNTERMEASURES 5 - 1 to 5 - 4

5.1 For 22kW or less of 1-axis ....................................................................................................................... 5 - 1

5.2 For 1kW or less of multi axis .................................................................................................................... 5 - 2

5.3 For 30kW or more .................................................................................................................................... 5 - 3

6. SUPPLEMENT 6 - 1 to 6 - 6

6.1 Reasons why the shield is grounded on both the cabinet side and the servo motor chassis side ....... 6 - 1

6.1.1 Grounding the shield at the servo amplifier side only ...................................................................... 6 - 1

6.1.2 Grounding the shield at both ends of the cable................................................................................ 6 - 2

6.2 Reasons why the grounding position in the cabinet is specified to be 10 cm or less from the

cabinet exit ............................................................................................................................................... 6 - 3

Page 3: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

2

6.3 Reasons why the shield must be grounded with the P clip or U clip ...................................................... 6 - 3

6.4 Connecting multiple servo amplifiers to one EMC filter (1: n connection) ............................................. 6 - 4

6.4.1 Selection method ............................................................................................................................... 6 - 4

6.4.2 Selection example ............................................................................................................................. 6 - 5

Page 4: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

1 - 1

1. SUMMARY

1. SUMMARY

We have carried out EMC standard compliance confirmation tests with the servo amplifier in the installation environment described in this manual. After incorporating the servo amplifier in the machine or equipment, confirm the EMC standard compliance of the entire machine or equipment on customer side.

For the EMC countermeasures, refer to this guideline or the instruction manual of the servo amplifier used.

Page 5: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

1 - 2

1. SUMMARY

MEMO

Page 6: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

2 - 1

2. EMC DIRECTIVE

2. EMC DIRECTIVE

Mitsubishi general-purpose AC servo MELSERVO complies with products standard EN 61800-3. This directive largely regulates the following two withstand levels.

(1) Emission (EMI: Electromagnetic Interference) Capacity to prevent output of obstructive noise that adversely affects external sources.

(2) Immunity (EMS: Electromagnetic Susceptibility) Capacity to not malfunction due to obstructive noise from external source.

The details of each level are classified below.

Class Name Details Products

standard

Emission

(EMI)

Radiated noise Electromagnetic noise radiated through the air,

etc.

EN 61800-3

Conducted noise Electromagnetic noise discharged from power

supply line, etc.

Immunity

(EMS)

Electrostatic discharge immunity test

IEC 61000-4-2

Noise from a charged human body, etc.

Radiated, radio-frequency, electromagnetic

field immunity test

IEC 61000-4-3

Electromagnetic noise from wireless transmitters

or broadcasting companies, etc.

Electrical fast transient/burst immunity test

IEC 61000-4-4

Relay noise or electromagnetic noise caused by

live electricity being turned on or off, etc.

Immunity to conducted disturbances,

induced by radio-frequency fields

IEC 61000-4-6

Electromagnetic noise flowed from power supply

wires or earthing wires, etc.

Power-frequency magnetic field immunity

test

IEC 61000-4-8

Electromagnetic noise of 50/60Hz power supply

frequency, etc.

Voltage dips, short interruptions and

voltage variations immunity tests

IEC 61000-4-11

Power supply drop, etc.

Surge immunity test

IEC 61000-4-5

Electromagnetic conducted noise discharged by

thunder, etc.

Page 7: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

2 - 2

2. EMC DIRECTIVE

MEMO

Page 8: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

3 - 1

3. EMC COUNTERMEASURES

3. EMC COUNTERMEASURES

CAUTION

The servo amplifier must be installed in the metal cabinet.

3.1 Basic EMC countermeasures

POINT

According to the NFPA79 approved by the United States, when the shielded wire is not used for wiring between a servo amplifier and a servo motor, the wiring must be insulated from wiring of other control or signal circuits. (Example: 100 mm or more for 20 A or less)

Take the following measures firmly as EMC countermeasures.

(1) Install the device in a sealed metal cabinet. (2) Install a noise filter.

(3) Accurately earth the device.

(4) Use shielded wires for cables and wires. (5) Separate the primary-side wiring and the secondary-side wiring as far as possible.

(6) Install the surge protector. (Refer to section 4.6.)

3.2 Cabinet design

The servo is a complex component incorporated into another machine. It must always be installed in a cabinet.

The design of the cabinet is a very important factor for EMC countermeasures, so please take the following points into consideration.

(1) Use a metal cabinet. (2) Accurately earth the cabinet unit with a thick and short cable.

Page 9: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

3 - 2

3. EMC COUNTERMEASURES

(3) Weld or screw close the joining sections of the cabinet's top plate and side plate. Keep the joining

clearance to 10cm or less. The diameter of the openings on the cabinet such as the ventilation hole should

be 10cm or less. If there are holes larger then this, plug them with metal plates or punched metal. In this case, such as when painted surfaces are to be connected, make sure that there is a good electrical connection to prevent antenna effect.

Example)

Remove paint

Hole exceeding10cm

Faraday cage effect grill

Provide an electrical continuity.

(4) The door of the cabinet must be accurately earthed with the cabinet. If the door earthing is insufficient, the

door itself will act as a large antenna and will radiate noise. Take the following measures for this.

1) Use a metal door.

2) Connect the door and cabinet with thick braided wire at as many points as possible.

3) Use an EMI gasket or conductive packing for the contact between the door and cabinet.

Cabinet

Metal cabinet

Enforce conductance treatment onsections that the EMI gasket contacts.

EMI gasket

Packingdoor

Page 10: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

3 - 3

3. EMC COUNTERMEASURES

(5) To take preventive measures against the noise of the input power source cable in the cabinet, install the

shielding partition at nearby site where the power is input so that the input power cable does not receive

harmful effects of the radiated noise.

AC input

Filter MCCB

Radiated noise

Cabinet

AC input

Filter MCCB

Radiated noise

Shieldingpartition

Controller Servo amplifier Controller Servo amplifier

Cabinet

The power supply line noise iseliminated by the filter, but cablecontains noise again because of thenoise radiated in the cabinet.

Use a metal plate, etc., for theshielding partition.Make sure there are no gaps.

Page 11: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

3 - 4

3. EMC COUNTERMEASURES

3.3 Filter wiring and installation

POINT

For when multiple servo amplifiers are connected to one EMC filter, refer to section 6.4.

(1) Wire the servo and filter as shown below.

Powersupply

Molded-casecircuit

breaker

EMCfilter

Magneticcontactor

Servo amplifier

Control circuitpower supply

Main circuitpower supply

Servomotor

Wiring length 1.5m or less (recommended)

(2) Arrange the EMC filter input cable and output cable as far apart as possible. If they are too close, the output line noise will be induced into the input cable, and effect of the filter will be lost. Separate these cables by at least 30cm or more.

EMCfilter

EMCfilter

Input(power supply side)

Output(servo amplifier side)

OK NG

Input(power supply side)

Output(servo amplifier side)

The output side noise is induced to the input side.

Page 12: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

3 - 5

3. EMC COUNTERMEASURES

(3) Installation of filter.

Install the servo amplifier and EMC filter on the same cabinet.

Install the filter on the right or left side of the servo amplifier, as shown below. (For details of the EMC filter, refer to section 4.2.) The surface inside the cabinet where the filter is to be installed must be bare metal or metal plated surface

so that the rear surface of the filter electrically contacts the cabinet. Treat the surface where the servo amplifier is installed in the same manner. The filter input wire (a) must be kept as far apart from the output wires (b), (c) and (d). Keep the wiring ((b), (c), (d)) between the filter and servo amplifier as short as

possible. (The sum of (b) and (c) is 1.5m or less.)

Cabinet

Servo amplifier

Filter

Bare metal ormetal platedsurface(no paint, etc)

Control circuitpower supply

Main circuitpower supply

Powersupplyinput

(b)

(c)

(d)

(a)

Magneticcontactor

Page 13: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

3 - 6

3. EMC COUNTERMEASURES

3.4 Cable treatment

(a) Securely earth the cabinets 1 and 2, and the servo motor.

(b) Keep the main circuit power supply cable of the servo amplifier, power cable of the servo motor, and wire for the control circuit signal apart (30 cm or more). These cables must not be routed in close parallel or bundled.

The following drawing shows an example of the installation. The methods for treating each cable are described separately.

(The numbers assigned to each cable in the drawing indicate section number of this manual where details are explained.)

Servo motor

Encoder

Section 3.4(1)

Servo amplifierControllerPower supply

Section 3.4(2)

EMC filter

Section 3.4(7)

Section 3.4(4)

Section 3.4(3)

Controller, etc.

Cabinet 2

Cabinet 1

Magneticcontactor

Section3.4(3)

Option

24VDCpowersupply

Surge protector

Page 14: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

3 - 7

3. EMC COUNTERMEASURES

(1) Servo motor power cable

POINT

If removing the insulator of a shield causes electrical shock or injuries and

threatens the machinery safety, additional protective covers or enclosures may be required.

Cabinet

To servoamplifier

Using shield cable

Shield cableServo motor

Connector

Earth with P or U clip

Conduit connector

Multiple core cableServo motor

Earth with surface paint removedCabinet

To servoamplifier Connector

Conduit

Using conduit

Keep asclose aspossible10cm or less

1) Use four wires (3-phase earth), that is completely shielded and that has no breakage for the servo

motor power cable. Connect the earth wire to the earth ( ) terminal on the servo amplifier and servo motor.

Material of shield has to be copper.

2) Connect the shield of the cable to the earth on both the cabinet side and servo motor chassis side.

For the reasons why the shield is grounded on both the cabinet side and the servo motor chassis side, refer to section 6.1. Earth the shield on the servo amplifier side at a position 10cm or less from the cabinet. For the reasons why the shield grounding position on the servo amplifier side is specified to

be 10 cm or less from the cabinet, refer to section 6.2.

3) Earth the shield with a metal P clip or U clip. For the reasons why the P clip or U clip is specified as a grounding method, refer to section 6.3.

Example of connectionwith P clip

Example of connectionwith U clip

Page 15: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

3 - 8

3. EMC COUNTERMEASURES

4) Directly earth the shield. It is not recommended to solder the wire to the braided wire (shield) and

ground with its end.

Example of earthingwith wire soldering

Solder

5) When not using a shield cable for the servo motor power cable, put the cable into a metal conduit.

6) Earth the servo motor power cable on the cabinet side with the conduit connector and cabinet side wall. (Remove paint from the side wall of the cabinet.)

7) When grounding the servo motor power cable connected to the servo motor, take the following

measure by fixing the cable cramp to the conduit connector shown in the following drawing.

Clamp fitting

Conduit

Conduit connector Connector

To earth (Use as thick and short wire as possible)

8) Keep the cable length at 50m or less. (2) Encoder cable

Cabinet

To servoamplifier

Shield twisted pair cable

ConnectorAs close aspossible

10cm or less

Use a shielded twisted pair cable, and earth on the servo amplifier and encoder side with a P clip or U clip. Keep the cable length at 50m or less.

Page 16: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

3 - 9

3. EMC COUNTERMEASURES

(3) Controller connection (command) cable (except for SSCNET III cable)

1) If controller and servo amplifier are in the same cabinet

Use a shielded twisted pair cable, and earth on the controller and servo amplifier side with a P clip or U clip. If the cable length is 2m or less, the earthing can be done at one position on the controller side.

As close aspossible

ServoamplifierController

Cabinet

Shield twisted pair cable

As close aspossible

2) If controller, etc. is in the different cabinet from servo amplifier

Use a shielded twisted pair cable and earth the shield on the controller, etc. and servo amplifier side with a P clip and U clip.

Controller,etc.

Cabinet

Servoamplifier

Cabinet

10cm or less

Shield twisted pair cable

10cm or less

(4) Cable of the same cabinet For the connection cables of the options such as the parameter unit or dynamic brake option, etc., arranged

in the same cabinet as the servo amplifier, use a shielded cable (shielded twisted pair cable for parameter unit). Earth the shield on the option and servo amplifier side with a P clip or U clip. If the cable length is 2m or less, the earthing can be done at one position on the servo amplifier side.

As close aspossible

ServoamplifierOption

Cabinet

As close aspossible

Page 17: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

3 - 10

3. EMC COUNTERMEASURES

(5) Regenerative option connection cable

For the regenerative option cable, use a twisted cable with shield or a twisted cable covered with shield

braid. Earth the shield on the option and servo amplifier with a P clip or U clip. The drawing shows the treatment for when the regenerative option is installed outside the cabinet.

As close aspossible

Regenerativeoption

Cabinet

10cm or less

Shield braid

Servoamplifier

Twisted cable

(6) Input power supply cable

Use the conventional multiple core cable. Using shielded input power cables increases the effect of EMC countermeasures.

(7) 24VDC cable (for servo amplifier) Use a vinyl wire or multiple core cable.

Page 18: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

4 - 1

4. EMC COUNTERMEASURE PARTS

4. EMC COUNTERMEASURE PARTS

This chapter explains parts used in EMC countermeasures. For details of the parts, contact the parts manufacturer.

4.1 Noise filter (For controller power supply)

For the noise filter installed to the controller, refer to the manual of the controller used.

4.2 EMC filter (For servo amplifier power supply)

POINT

For connection with servo amplifiers, refer to each servo amplifier instruction manual.

For when multiple servo amplifiers are connected to one EMC filter, refer to section 6.4.

It is recommended to use the following filter. Some EMC filters are large in leakage current. Some EMC filters for servo amplifiers of special specifications (such as RJ, ED, PX, RU, and RZ) are also large in leakage

current. Select a molded-case circuit breaker in considering the increase of leakage current, so that the leakage current does not affect servo amplifiers, converter units and drive units.

Refer to instruction manuals of each product for the products other than series described in this section. (1) Combination of 22kW or less servo amplifiers and filters

(a) For MR-J4 series

Servo amplifier

Recommended filter (SOSHIN Electric Co., Ltd) Mass

[kg] ([lb]) Model Rated current

[A]

Rated voltage

[VAC]

Leakage

current [mA]

MR-J4-10 to MR-J4-100

MR-J4W2-22B MR-J4W3-222B HF3010A-UN (Note)

10

250

5

3.5 (7.72)

MR-J4W2-44B HF3010A-UN2 (Note)

MR-J4-200 MR-J4-350

MR-J4W2-77B MR-J4W2-1010B

MR-J4W3-444B

HF3030A-UN (Note) 30 5.5 (12.13)

MR-J4-500 MR-J4-700 HF3040A-UN (Note) 40 6.5

6 (13.23)

MR-J4-11K to MR-J4-22K HF3100A-UN (Note) 100 12 (26.46)

MR-J4-60 4 MR-J4-100 4 TF3005C-TX 5 6 (13.23)

MR-J4-200 4 to MR-J4-700 4 TF3020C-TX 20

MR-J4-11K 4 TF3030C-TX 30 500 5.5 7.5 (16.54)

MR-J4-15K 4 TF3040C-TX 40 12.5 (27.56)

MR-J4-22K 4 TF3060C-TX 60

MR-J4-10 1 to MR-J4-40 1 HF3010A-UN (Note) 10 250 5 3.5

Note. A surge protector is separately required to use any of these EMC filters. (Refer to section 4.6.)

Page 19: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

4 - 2

4. EMC COUNTERMEASURE PARTS

Servo amplifier

Recommended filter (COSEL Co., Ltd) Mass

[kg] ([lb]) Model Rated current

[A]

Rated voltage

[VAC]

Leakage

current [mA]

MR-J4-11K to MR-J4-22K FTB-100-355-L (Note) 100 500 40 5.3 (11.69)

MR-J4-22K 4 FTB-80-355-L (Note) 80 500 80 5.3 (11.69)

Note. A surge protector is separately required to use any of these EMC filters. (Refer to section 4.6.)

(b) For MR-JN series

Servo amplifier

Recommended filter (SOSHIN Electric Co., Ltd) Mass

[kg] ([lb]) Model Rated current

[A]

Rated voltage

[VAC]

Leakage

current [mA]

MR-JN-10A(1) to MR-JN-20A(1)

MR-JN-40A HF3010A-UN (Note) 10 250 5 3.5 (7.72)

Note. A surge protector is separately required to use any of these EMC filters. (Refer to section 4.6.)

(c) For MR-J3W series

Servo amplifier

Recommended filter (SOSHIN Electric Co., Ltd) Mass

[kg] ([lb]) Model Rated current

[A]

Rated voltage

[VAC]

Leakage

current [mA]

MR-J3W-22B MR-J3W-44B HF3010A-UN (Note) 10 250 5

3.5 (7.72)

MR-J3W-77B MR-J3W-1010B HF3030A-UN (Note) 30 5.5 (12.13)

Note. A surge protector is separately required to use any of these EMC filters. (Refer to section 4.6.)

(d) For MR-J3 series

Servo amplifier

Recommended filter (SOSHIN Electric Co., Ltd)

Mass [kg] ([lb])Model

Rated current

[A]

Rated voltage

[VAC]

Leakage

current [mA]

MR-J3-10 to MR-J3-100

MR-J3-10 1 to MR-J3-40 1 HF3010A-UN (Note) 10

5 3.5 (7.72)

MR-J3-200 MR-J3-350 HF3030A-UN (Note) 30 250 5.5 (12.13)

MR-J3-500 MR-J3-700 HF3040A-UN (Note) 40 6.5

6.0 (13.23)

MR-J3-11K to MR-J3-22K HF3100A-UN (Note) 100 12 (26.46)

MR-J3-60 4 MR-J3-100 4 TF3005C-TX 5 6.0 (13.23)

MR-J3-200 4 to MR-J3-700 4 TF3020C-TX 20

MR-J3-11K 4 TF3030C-TX 30 500 5.5 7.5 (16.54)

MR-J3-15K 4 TF3040C-TX 40 12.5 (27.56)

MR-J3-22K 4 TF3060C-TX 60

Note. A surge protector is separately required to use any of these EMC filters. (Refer to section 4.6.)

(e) For MR-J2-Super series

POINT

The production of the MR-J2-Super series was discontinued in August 2015.

Servo amplifier

Recommended filter (DEM Manufacturing Ltd.)

Mass [kg] ([lb])Model

Rated current

[A]

Rated voltage

[VAC]

Leakage

current [mA]

MR-J2S-10 to MR-J2S-100

MR-J2S-10 1 to MR-J2S-40 1 SF1252 10.5

250 38 0.75 (1.65)

MR-J2S-200 MR-J2S-350 SF1253 27.5 57 1.37 (3.02)

Page 20: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

4 - 3

4. EMC COUNTERMEASURE PARTS

Servo amplifier

Recommended filter (SOSHIN Electric Co., Ltd)

Mass [kg] ([lb])Model

Rated current

[A]

Rated voltage

[VAC]

Leakage

current [mA]

MR-J2S-500 HF3040A-TM (Note) 40 1.5

5.5 (12.13)

MR-J2S-700 HF3050A-TM (Note) 50 6.7 (14.77)

MR-J2S-11K HF3060A-TMA (Note) 60 250 10.0 (22.05)

MR-J2S-15K HF3080A-TMA (Note) 80 3.0 13.0 (28.66)

MR-J2S-22K HF3100A-TMA (Note) 100 14.5 (31.97)

MR-J2S-60 4 to MR-J2S-200 4 TF3005C-TX 5 6 (13.23)

MR-J2S-350 4 to MR-J2S-700 4 TF3020C-TX 20

MR-J2S-11K 4 TF3030C-TX 30 500 5.5 7.5 (16.54)

MR-J2S-15K 4 TF3040C-TX 40 12.5 (27.56)

MR-J2S-22K 4 TF3060C-TX 60

Note. A surge protector is separately required to use any of these EMC filters. (Refer to section 4.6)

(2) Combination of 30kW or more converter unit, drive unit and filter (a) For MR-J4 series

Converter unit Drive unit Recommended filter (SOSHIN Electric Co., Ltd)

Mass [kg] ([lb])Model

Rated current [A]

Rated voltage [VAC]

Leakage current [mA]

MR-CR55K MR-J4-DU30K MR-J4-DU37K

HF3200A-UN (Note)

200 250 9 18

(39.68)

MR-CR55K4

MR-J4-DU30K 4 MR-J4-DU37K 4 MR-J4-DU45K 4 MR-J4-DU55K 4

TF3150C-TX 150 500 5.5 31

(68.34)

Note. A surge protector is separately required to use any of these EMC filters. (Refer to section 4.6.)

Converter unit Drive unit Recommended filter (COSEL Co., Ltd)

Mass [kg] ([lb])Model

Rated current [A]

Rated voltage [VAC]

Leakage current [mA]

MR-CR55K4

MR-J4-DU30K 4 MR-J4-DU37K 4 MR-J4-DU45K 4 MR-J4-DU55K 4

FTB-150-355-L(Note)

150 500 80 7.8

(17.12)

Note. A surge protector is separately required to use any of these EMC filters. (Refer to section 4.6.)

(b) For MR-J3 series

Converter unit Drive unit

Recommended filter (SOSHIN Electric Co., Ltd) Mass

[kg] ([lb])Model Rated current

[A]

Rated voltage

[VAC]

Leakage current

[mA]

MR-J3-CR55K MR-J3-DU30K

MR-J3-DU37K

HF3200A-UN

(Note) 200 250 9

18

(39.68)

MR-J3-CR55K4 MR-J3-DU30K 4 to

MR-J3-DU55K 4 TF3150C-TX 150 500 5.5

31

(68.34)

Note. A surge protector is separately required to use any of these EMC filters. (Refer to section 4.6.)

Page 21: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

4 - 4

4. EMC COUNTERMEASURE PARTS

(c) For MR-J2-Super series

POINT

The production of the MR-J2-Super series was discontinued in August 2015.

Converter unit Drive unit

Recommended filter (SOSHIN Electric Co., Ltd) Mass

[kg] ([lb])Model Rated current

[A]

Rated voltage

[VAC]

Leakage current

[mA]

MR-HP30KA MR-J2S-30K

MR-J2S-37K

HF3200A-TMA

(Note) 200 250 3

23.5

(51.81)

MR-HP55KA4

MR-J2S-30K 4 to

MR-J2S-45K 4 TF3150C-TX 150 500 5.5 31

(68.34)MR-J2S-55K 4

Note. A surge protector is separately required to use any of these EMC filters. (Refer to section 4.6.)

[SF1252, SF1253 wire connection method]

Flat bladed screwdriver

Wire

1) Peel the wire insulator.

CoreInsulator

9mm Core length for SF1252

14mm Core length for SF1253

2) Insert the core of the cable into the opening, and tighten with the slotted screwdriver. In addition, connect the cables to the terminals of SF1252 or SF1253 in a one-to-one connection.

EMC filter Screw size Tightening torque

SF1252 2.5mm 0.598N m

SF1253 3mm 0.794N m

Page 22: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

4 - 5

4. EMC COUNTERMEASURE PARTS

4.3 Ferrite core (Data line filter)

Noise can be prevented by installing a data line filter onto the cables connected to the servo amplifier. The data line filter in the following is one such example.

Model (Note) Impedance ( )

ZCAT3035-1330 10 to 100MHz 100 to 500MHz

(Manufactured by TDK) 80 150

Note. The above values of impedance do not refer to the guaranteed values but the impedance values of the data line filter

including those of the cable (measured reference values).

ESD-SR-250 by NEC TOKIN, E04SRM563218 by SEIWA ELECTRIC, etc. are also available.

[Usage example]

Passing through once Passing through twice Passing through three times

4.4 Shield clamp fitting

Generally, the earth of the shielded cable may only be connected to the connector’s SD terminal. However, the effect can be increased by directly connecting the cable to an earth plate as shown below. Install the earth plate near the servo amplifier for the encoder cable. Peel part of the cable insulator tot expose

the external conductor, and press that part against the earth plate with the cable clamp. If the cable is thin, clamp several cables in bunch. The clamp comes as a set with the earth plate.

Strip the cable insulator ofthe clamp area

Cable

Cable

Clamp section diagram

External conductor

Earth plateCable clamp

Cutter

Model Accessory fittings

AERSBAN-DSET 2 cable cramps

AERSBAN-ESET 1 cable cramp

Page 23: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

4 - 6

4. EMC COUNTERMEASURE PARTS

4.5 Line noise filter

The line noise filter is effective in suppressing noises radiated from the cables connected to the main circuit power in the servo amplifier (converter unit) and those connected to the servo amplifier power output, and also in suppressing high-frequency leakage current (zero-phase current) especially within 0.5MHz to 5MHz band.

4.5.1 Connection example

The line noise filters are used for the cables connected to (L1, L2, and L3) the main circuit power supply and for

those connected to (U, V, and W) the servo amplifier power output. Pass each of 3-phase cables through line noise filters an equal number of times in the same direction.

(1) For use of 1 line noise filter

Powersupply

L3

L2

L1

Servo amplifier(Converter unit)

(4 times pass)

(2) For use of 2 line noise filters separately

Powersupply

L3

L2

L1

Servo amplifier(Converter unit)

(4 times pass)

(3) For use of 2 line noise filters closely

Powersupply

L3

L2

L1

Servo amplifier(Converter unit)

(4 times pass)

Page 24: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

4 - 7

4. EMC COUNTERMEASURE PARTS

(4) For use of 4 line noise filters closely

Powersupply

L3

L2

L1

Servo amplifier(Converter unit)

(4 times pass)

Use the following models of the line noise filter in accordance with the capacity of the servo amplifier, converter unit, and drive unit. 2kW or less : FR-BSF01 (for the wire size of 3.5mm2 (AWG12) or less)

3.5kW or more: FR-BLF (for the wire size of 5.5mm2 (AWG10) or less) 4.5.2 Precautions

(1) When the line noise filter is used for the main circuit power side in the servo amplifier (converter unit), the effect of the filters is produced as the number of passes increases. The appropriate number of passage is

four times. (2) When using the line noise filter for the cable connected to the servo amplifier power output, pass through

four times or less. (3) Do not pass the earth wire through the line noise filter. Doing so may result in reducing the effect.

(4) Place the line noise filter as close to the servo amplifier as possible so that the effect of suppressing noises

can increase.

(5) The line noise filter can be also used not only for the cables connected to the main circuit power supply in

the servo amplifier (converter unit) or the cables connected to the servo amplifier power output but also the

servo motor brake cable, encoder cable, and control signal cable. Pass through four times or less in this case. However, prevent the line noise filter from damaging the servo amplifier, converter unit, drive unit, and/or servo motor in considering the flexing life of the encoder cable.

Page 25: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

4 - 8

4. EMC COUNTERMEASURE PARTS

4.6 Surge protector

POINT

The surge protector is required to use the EMC filter with a 200 V class servo amplifier.

The surge protector is required to use the EMC filter manufactured by COSEL with a 400 V class servo amplifier.

To prevent damage due to the applied surge to the AC power supply line (lightning, sparks, etc.), connect the following surge protector (Okaya Electric Industries) to the main circuit power supply (L1, L2, and L3).

(a) For MR-J4 series

Surge protector model

Max. continuous

operating

Voltage 50/60Hz

DC breakdown

voltage

Voltage

protection level

Normal discharge

current 8/20 s

Max. discharge

current 8/20 s

Surge current life

8/20 s-1000A

RSPD-250-U4 3AC 250V 700V 25% 1300V 2500A 5000A Approx. 300

times

RSPD-500-U4 3AC 500V 1300V 25% 2000V 2500A 5000A Approx. 300

times

(b) For MR-JN MR-J3W MR-J3 MR-J2-Super series

POINT

The production of the MR-J2-Super series was discontinued in August 2015.

Surge protector model Circuit voltage

50/60Hz

Maximum

allowable circuit

voltage

Clamp voltageSurge immunity

8/20 s

Surge

compression

1.2/50 s

Static capacity

RAV-781BYZ-2 3AC 250V 300V 783V 10% 2500A 20kV 75pF

RAV-781BXZ-4 3AC 250V 300V 1700V 10% 2500A 2kV 75pF

Page 26: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

5 - 1

5. CONNECTION EXAMPLE FOR EMC COUNTERMEASURES

5. CONNECTION EXAMPLE FOR EMC COUNTERMEASURES

5.1 For 22kW or less of 1-axis

Filter Magneticcontactor

24VDC

Option

Controller,etc.

ControllerFilter

Regenerativeoption

( )

Cable clamp : Section 3.4(3), 4.4

Noise filter : Section 4.1

Cable clamp : Section 3.4(4), 4.4

(Note 1) (Note 1)

(Note 2)

(Note 1)

Cabinet : Section 3.2(1), (2), (3), (4)

Cable clamp : Section 3.4(5), 4.4

(Note 1)

Cable clamp : Section 3.4(3)-2), 4.4

(Note 1)

(Note 1)

(Note 2)

EMC filter: Section 4.2

(Note 1)

Cabinet: Section 3.2(1), (2), (3), (4)

(Note 1)

(Note 2)

(Note 2)

L1, L2, L3

L11, L21

P, C

Cable clamp : Section 3.4(5), 4.4

(Note 1)

Encoder

Cable clamp : Section 3.4(2), 4.4

(Note 1)

Cable clamp : Section 3.4(1), 4.4

(Note 1)

U, V, W

(Note 2)

(Note 3)

(Note 4)

1-axisServo amplifier

UVWServo motor

Surgeprotector

Note 1. Specific EMC countermeasures are shown as . 2. Shielded cables are shown as . 3. Shielded cables or conduits are shown as . 4. When the control circuit power supply (L11 L21) of the servo amplifier is 24VDC, connect AC/DC power supply.

Page 27: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

5 - 2

5. CONNECTION EXAMPLE FOR EMC COUNTERMEASURES

5.2 For 1kW or less of multi axis

Surgeprotector Filter Magnetic

contactor

24VDC

Option

Controller,etc.

ControllerFilter

Regenerativeoption

( )

Cable clamp : Secion 3.4(3), 4.4

Noise filter : Section 4.1

Cable clamp : Section 3.4(4), 4.4

(Note 1) (Note 1)

(Note 2)

(Note 1)

Cabinet : Section 3.2(1), (2), (3), (4)

Cable clamp : Section 3.4(5), 4.4

(Note 1)

Cable clamp : Section 3.4(3)-2), 4.4

(Note 1)

(Note 1)

(Note 2)

EMC filter: Section 4.2

(Note 1)

Cabinet: Section 3.2(1), (2), (3), (4)(Note 1)

(Note 2)

(Note 2)

L1, L2, L3

L11, L21

P, C

Cable clamp : Section 3.4(5), 4.4

(Note 1)

Encoder

Cable clamp : Section 3.4(2), 4.4

(Note 1)

Cable clamp : Section 3.4(1), 4.4

(Note 1)

U, V, W

(Note 2)

(Note 3)

Encoder

Cable clamp : Section 3.4(2), 4.4

(Note 1)

Cable clamp : Section 3.4(1), 4.4

(Note 1)

U, V, W

(Note 2)

(Note 3)

Multi axisservo amplifier

(Note 4)

UVWServo motor

UVWServo motor

Note 1. Specific EMC countermeasures are shown as .

2. Shielded cables are shown as .

3. Shielded cables or conduits are shown as .

4. The figure is for the 2-axis servo amplifier.

Page 28: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

5 - 3

5. CONNECTION EXAMPLE FOR EMC COUNTERMEASURES

5.3 For 30kW or more

POINT

The production of the MR-J2-Super series was discontinued in August 2015.

Surgeprotector

Controller,etc.

Encoder

Cabinet : Section 3.2(1), (2), (3), (4)

Cable clamp: Section 3.4(2), 4.4

(Note 1)

Cable clamp : Section 3.4(3)-2), 4.4

(Note 1)

(Note 1)

(Note 2)

(Note 2) (Note 3)

Cable clamp : Section 3.4(1), 4.4

(Note 1)

Cable clamp : Section 3.4(2), 4.4

(Note 1)

Cable clamp : Section 3.4(4), 4.4

(Note 1)

Cable clamp : Section 3.4(3), 4.4

(Note 1) U, V, W

Converter unitMR-CR55K(4)

MR-J3-CR55K(4)MR-HP30KA

MR-HP55KA4

Cable clamp : Section 3.4(1), 4.4

(Note 1)

Cable clamp : Section 3.4(5), 4.4

(Note 1)

Regenerativeoption

( )

Cabinet: Section 3.2(1), (2), (3), (4)

(Note 1)

Filter

24VDC

Option

ControllerFilter

Noise filter : Section 4.1

(Note 1)

(Note 2)

(Note 2)

EMC filter: Section 4.2

(Note 1)

L1, L2, L3

L11, L21

P2, C

L , L (Note 4)

L , L (Note 5)

(Note 2)

(Note 6) Protectioncoordinationcable

24VDC

L11, L21

(Note 2)

(Note 6)

(Note 7)Magneticcontactor

Drive unitMR-J4-DU (4)MR-J3-DU (4)

Servo amplifierMR-J2S- (4)

UVWServo motor

Page 29: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

5 - 4

5. CONNECTION EXAMPLE FOR EMC COUNTERMEASURES

Note 1. Specific EMC countermeasures are shown as .

2. Shielded cables are shown as .

3. Shielded cables or conduits are shown as .

4. The abbreviations of the terminals are P and N for MR-HP30KA or MR-HP55KA4.

5. The abbreviations of the terminals are P and N for MR-J2S- (4).

6. Connect the converter unit and drive unit with the provided bus bar.

7. The abbreviation of the terminal is P for MR-HP30KA or MR-HP55KA4.

Page 30: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

6 - 1

6. SUPPLEMENT

6. SUPPLEMENT

6.1 Reasons why the shield is grounded on both the cabinet side and the servo motor chassis side

As for a countermeasure against radiated emissions from inverters or servo amplifiers, multiple point grounding,

in which grounding is performed at the cabinet exit and both ends of the cable between the servo amplifier and the servo motor, tends to decrease unnecessary noise.

6.1.1 Grounding the shield at the servo amplifier side only

The following figure shows only wiring of the servo motor power cable. Use a shielded wire for the detector

cable as well as the power cable. Figure 6.2 shows one of measurement result examples. It does not guarantee the effect of the countermeasure.

Cabinet

To servoamplifier

When a shielded wire is used

Shielded cableServo motor

Servo motor

Motor

Shield

Connector

Connect the shield part or earthwire coming out outside thecabinet with the earth terminalof the connector at the servomotor side.

Grounding

10 cm or less

M

UVW

Fig. 6.1 When the cable between the servo amplifier and servo motor

is grounded on the servo amplifier side only

LIMIT: IEC/EN 61800-3 (10 m)

[dBuV/m]100

100 200 300Frequency

×: Ver. (QP)○: Hor. (QP)

HORIZONTAL/VERTICAL

90

80

70

70

60

50

50

40

30

30

20

10

0

Fig. 6.2 Radiated emissions of when the cable between the servo amplifier and servo motor is grounded on the servo amplifier side

Page 31: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

6 - 2

6. SUPPLEMENT

6.1.2 Grounding the shield at both ends of the cable

The following figure shows only wiring of the servo motor power cable. Use a shielded wire for the detector cable as well as the power cable. Figure 6.4 shows one of measurement result examples. It does not guarantee the effect of the countermeasure.

Cabinet

To servoamplifier

When a shielded wire is used

Shielded cableServo motor

ConnectorAs close aspossible

10 cmor less

Grounding with the P or U clip

Fig. 6.3 When both ends of the cable between the servo amplifier and servo motor are grounded

LIMIT: IEC/EN 61800-3 (10 m)

[dBuV/m]100

100 200 300Frequency

×: Ver. (QP)○: Hor. (QP)

HORIZONTAL/VERTICAL

90

80

70

70

60

50

50

40

30

30

20

10

0

Fig. 6.4 Radiated emissions of when both ends of the cable between the servo amplifier and servo motor are grounded

Page 32: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

6 - 3

6. SUPPLEMENT

6.2 Reasons why the grounding position in the cabinet is specified to be 10 cm or less from the cabinet exit

Various devices are installed inside the cabinet. The devices radiate or transmit significant unnecessary noise. The generated noise may not be held inside the cabinet depending on a cable wiring method. When unnecessary noise is superimposed in the cable, grounding the cable near the cabinet exit should

prevent the noise from flowing outside the cabinet. Thus, grounding within 10 cm from the cabinet exit is recommended.

Cabinet

To servoamplifier

Shielded cable

10 cm or less

DeviceNoise

6.3 Reasons why the shield must be grounded with the P clip or U clip

POINT

If removing the insulator of a shield causes electrical shock or injuries and

threatens the machinery safety, additional protective covers or enclosures may be required.

The surface of a shielded cable is covered with metallic foil or braid (braided wire). High-frequency noise is

passed through the shield and unnecessary noise is released outside to the ground, lowering the radiated emissions level. As to grounding the shielded cable, grounding with the P clip or U clip lowers impedance to the ground and

allows noise current to flow more smoothly than soldering the wire to the shield or holding the shield cables and extending the length. Thus, grounding with the P clip or U clip is recommended.

Example of groundingwith the P clip

Example of groundingwith the U clip

Example of groundingwith wire soldering

solder

Page 33: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

6 - 4

6. SUPPLEMENT

6.4 Connecting multiple servo amplifiers to one EMC filter (1: n connection)

Confirm the EMC standard compliance of the entire machine or equipment on customer side. 6.4.1 Selection method

Molded-casecircuit

breaker

Powersupply

Molded-casecircuit

breaker

Magneticcontactor

EMC filter

Servo amplifier(First)

Main circuitpower supply

Control circuitpower supply

Servo motor powercable length

Molded-casecircuit

breaker

Magneticcontactor

Servo amplifier(Second)

Main circuitpower supply

Control circuitpower supply

Servo motor powercable length

Molded-casecircuit

breaker

Magneticcontactor

Servo amplifier(nth)

Main circuitpower supply

Control circuitpower supply

Servo motor powercable length

Servomotor

Servomotor

Servomotor

Fig. 6.5 Connecting multiple servo amplifiers to one EMC filter When multiple servo amplifiers are connected to one EMC filter with the total length of servo motor power

cables too long, the magnetized parts of the EMC filter become magnetically saturated and the noise attenuation properties may be lower than expected. To gain the desired noise attenuation properties with every servo amplifier, select the EMC filter that satisfies

the following formulas (6.1 to 6.3) and conditions in Table 6.1. EMC filter rated input voltage [V] ≥ Servo amplifier rated input voltage [V] ············································ (6.1) EMC filter rated input current [A] ≥ Total rated input current of each servo amplifier [A] ··························· (6.2)

Total length of servo motor power cables supported by the EMC filter [m] ≥ Total length of servo motor power cables [m] ··································· (6.3)

Table 6.1 EMC filter selection

Total length of servo motor power cable [m]

EMC filter (Soshin Electric)

Rated input current [A] Rated input voltage [V] Leakage current [mA]

100 HF3030C-SZL 30 500 7 200 HF3060C-SZL 60 500 7 250 HF3100C-SZL 100 500 7 250 HF3150C-SZL 150 500 7

Page 34: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

6 - 5

6. SUPPLEMENT

6.4.2 Selection example

The following figure shows a connection example of when three servo amplifiers (MR-J4-100A) are connected with one EMC filter.

Servo motor powercable length 15 m

Servo motor powercable length 30 m

Molded-casecircuit

breaker

Powersupply

Molded-casecircuit

breaker

MagneticcontactorEMC filter

Servo amplifier

Main circuitpower supply

Control circuitpower supply

Model: MR-J4-100ARated input:

Voltage: 3-phase 200 V AC to 240 V ACCurrent: 5 A

Servo motor powercable length 15 m

Molded-casecircuit

breaker

Magneticcontactor

Servo amplifier

Main circuitpower supply

Control circuitpower supply

Model: MR-J4-100ARated input:

Voltage: 3-phase 200 V AC to 240 V ACCurrent: 5 A

Molded-casecircuit

breaker

Magneticcontactor

Servo amplifier

Main circuitpower supply

Control circuitpower supply

Model: MR-J4-100ARated input:

Voltage: 3-phase 200 V AC to 240 V ACCurrent: 5 A

Servomotor

Servomotor

Servomotor

A selection result can be obtained by applying the formulas of 6.1 to 6.3. EMC filter rated input voltage: 500 V ≥ Servo amplifier rated input voltage: 3-phase 200 V AC to 240 V AC EMC filter rated input current: 30 [A] ≥ Total rated input current of servo amplifiers: 15 [A]

Total length of servo motor power cables supported by the EMC filter: 100 [m] ≥ Total length of servo motor power cables: 60 [m]

According to Table 6.1, HF3030C-SZL can be selected.

Page 35: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

6 - 6

6. SUPPLEMENT

MEMO

Page 36: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

REVISIONS

*The manual number is given on the bottom left of the back cover.

Print Data *Manual Number Revision Apr. 1996 IB(NA)67310-* First edition Nov. 1997 IB(NA)67310-A Chapter 2

Chapter 5 Chapter 6

Table revisions Addition Addition

Nov. 2008 IB(NA)67310-B All pages change Jul. 2009 IB(NA)67310-C Chapter 2

Section 4.2 Section 4.2 (2)(b) Section 5.1

Change of table Part added Part changed Note 4 and 5 added

Jan. 2012 IB(NA)67310-D Chapter 1 Chapter 3 Section 3.1 Section 3.2 Section 3.3 Section 3.4 Section 4.1 Section 4.2 Section 4.3 Section 4.5 Section 4.6 Section 5.1 Section 5.2 Section 5.3

All pages change CAUTION added Part changed Part changed Part changed Part changed Part changed Part added, part changed Part changed Part changed Added Title changed “For 22kW or less” “For 22kW or less of 1-axis” Part change of diagram Added as “For 1kW or less of multi axis” Changes to section 5.3 to section 5.2 of the C version Part change of diagram

Feb. 2013 IB(NA)67310-E Section 4.2 Section 4.2 (1)(a) Section 4.2 (1)(f) Section 4.2 (2)(c) Section 4.6

POINT is added Part added Deleted Deleted POINT is added

Mar. 2014 IB(NA)67310-F 100V class MR-J4 series servo amplifiers are added. Section 4.2 (1)(a)

Section 4.3 MR-J4-10 1 to MR-J4-40 1 are added. E04SRM563218 is added.

Oct. 2014 IB(NA)67310-G MR-J4-DU is added. Section 4.2 (2)(a) Section 5.3

MR-J4-DU30K to MR-J4-DU55K are added. MR-CR55K and MR-J4-DU are added.

Dec. 2015 IB(NA)67310-H Chapter 6 is added. Section 3.1 Section 3.3 Section 3.3 (1) Section 3.4 (1) Section 3.4 (3) Section 4.2 Section 4.6 Chapter 6

POINT is added. Partially changed. POINT is added. Partially changed. Partially added. POINT is added. Partially changed. Partially added. POINT is added. Partially added. POINT is added. Partially added. Newly added.

This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.

© 1996 MITSUBISHI ELECTRIC CORPORATION

Page 37: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

MELSERVO is a trademark or registered trademark of Mitsubishi Electric Corporation in Japan and/or other countries. All other product names and company names are trademarks or registered trademarks of their respective companies.

Country/Region Sales office Tel/Fax USA Mitsubishi Electric Automation, Inc.

500 Corporate Woods Parkway, Vernon Hills, IL 60061, U.S.A.

Tel Fax

: +1-847-478-2100: +1-847-478-2253

Mexico Mitsubishi Electric Automation, Inc. Mexico BranchMariano Escobedo #69, Col. Zona Industrial, Tlalnepantla Edo. Mexico, C.P.54030

Tel Fax

: +52-55-3067-7500: –

Brazil Mitsubishi Electric do Brasil Comercio e Servicos Ltda.Rua Jussara, 1750- Bloco B Anexo, Jardim Santa Cecilia, CEP 06465-070, Barueri - SP, Brasil

Tel Fax

: +55-11-4689-3000: +55-11-4689-3016

Germany Mitsubishi Electric Europe B.V. German BranchMitsubishi-Electric-Platz 1, 40882 Ratingen, Germany

Tel Fax

: +49-2102-486-0: +49-2102-486-1120

UK Mitsubishi Electric Europe B.V. UK BranchTravellers Lane, UK-Hatfield, Hertfordshire, AL10 8XB, U.K.

Tel Fax

: +44-1707-28-8780: +44-1707-27-8695

Italy Mitsubishi Electric Europe B.V. Italian BranchCentro Direzionale Colleoni - Palazzo Sirio, Viale Colleoni 7, 20864 Agrate Brianza (Milano), Italy

Tel Fax

: +39-039-60531: +39-039-6053-312

Spain Mitsubishi Electric Europe B.V. Spanish BranchCarretera de Rubi, 76-80-Apdo. 420, 08190 Sant Cugat del Valles (Barcelona), Spain

Tel Fax

: +34-935-65-3131: +34-935-89-1579

France Mitsubishi Electric Europe B.V. French Branch25, Boulevard des Bouvets, 92741 Nanterre Cedex, France

Tel Fax

: +33-1-55-68-55-68: +33-1-55-68-57-57

Czech Republic Mitsubishi Electric Europe B.V. Czech BranchAvenir Business Park, Radlicka 751/113e, 158 00 Praha 5, Czech Republic

Tel Fax

: +420-251-551-470: +420-251-551-471

Poland Mitsubishi Electric Europe B.V. Polish Branchul. Krakowska 50, 32-083 Balice, Poland

Tel Fax

: +48-12-347-65-00: +48-12-630-47-01

Russia Mitsubishi Electric (Russia) LLC St. Petersburg BranchPiskarevsky pr. 2, bld 2, lit “Sch”, BC “Benua”, office 720; 195027 St. Petersburg, Russia

Tel Fax

: +7-812-633-3497: +7-812-633-3499

Sweden Mitsubishi Electric Europe B.V. (Scandinavia)Fjelievagen 8, SE-22736 Lund, Sweden

Tel Fax

: +46-8-625-10-00: +46-46-39-70-18

Turkey Mitsubishi Electric Turkey A.S. Umraniye BranchSerifali Mahallesi Nutuk Sokak No:5, TR-34775 Umraniye / Istanbul, Turkey

Tel Fax

: +90-216-526-3990: +90-216-526-3995

UAE Mitsubishi Electric Europe B.V. Dubai BranchDubai Silicon Oasis, P.O.BOX 341241, Dubai, U.A.E.

Tel Fax

: +971-4-3724716: +971-4-3724721

South Africa Adroit Technologies 20 Waterford Office Park, 189 Witkoppen Road, Fourways, South Africa

Tel Fax

: +27-11-658-8100: +27-11-658-8101

China Mitsubishi Electric Automation (China) Ltd.Mitsubishi Electric Automation Center, No.1386 Hongqiao Road, Shanghai, China

Tel Fax

: +86-21-2322-3030: +86-21-2322-3000

Taiwan SETSUYO ENTERPRISE CO., LTD.6F, No.105, Wugong 3rd Road, Wugu District, New Taipei City 24889, Taiwan

Tel Fax

: +886-2-2299-2499: +886-2-2299-2509

Korea Mitsubishi Electric Automation Korea Co., Ltd.7F-9F, Gangseo Hangang Xi-tower A, 401, Yangcheon-ro, Gangseo-Gu, Seoul 07528, Korea

Tel Fax

: +82-2-3660-9510: +82-2-3664-8372/8335

Singapore Mitsubishi Electric Asia Pte. Ltd. 307 Alexandra Road, Mitsubishi Electric Building, Singapore 159943

Tel Fax

: +65-6473-2308: +65-6476-7439

Thailand Mitsubishi Electric Factory Automation (Thailand) Co., Ltd.12th Floor, SV.City Building, Office Tower 1, No. 896/19 and 20 Rama 3 Road, Kwaeng Bangpongpang, Khet Yannawa, Bangkok 10120, Thailand

Tel Fax

: +66-2682-6522 to 6531: +66-2682-6020

Indonesia PT. Mitsubishi Electric Indonesia Gedung Jaya 11th Floor, JL. MH. Thamrin No.12, Jakarta Pusat 10340, Indonesia

Tel Fax

: +62-21-3192-6461: +62-21-3192-3942

Vietnam Mitsubishi Electric Vietnam Company LimitedUnit 01-04, 10th Floor, Vincom Center, 72 Le Thanh Ton Street, District 1, Ho Chi Minh City, Vietnam

Tel Fax

: +84-8-3910-5945: +84-8-3910-5947

India Mitsubishi Electric India Pvt. Ltd. Pune BranchEmerald House, EL-3, J Block, M.I.D.C., Bhosari, Pune - 411026, Maharashtra, India

Tel Fax

: +91-20-2710-2000: +91-20-2710-2100

Australia Mitsubishi Electric Australia Pty. Ltd.348 Victoria Road, P.O. Box 11, Rydalmere, N.S.W 2116, Australia

Tel Fax

: +61-2-9684-7777: +61-2-9684-7245

IB(NA)67310-H

Page 38: EMC Installation Guidelines - Mitsubishi · PDF fileEMC Installation Guidelines 1CW950 EMC INSTRUCTION GUIDELINES HEAD OFFICE : ... 6.1.2 Grounding the shield at both ends of the cable

IB (NA) 67310-H (1512) MEE Printed in Japan Specifications are subject to change without notice. This Guidelines uses recycled paper.

MODEL

MODELCODE

General-Purpose AC Servo

H

EMC InstallationGuidelines

1CW950

EMC INSTRUCTION GUIDELINES

HEAD OFFICE : TOKYO BLDG MARUNOUCHI TOKYO 100-8310