Embracing Localization Inaccuracy - A Case Study
-
Upload
usman-raza -
Category
Technology
-
view
344 -
download
2
description
Transcript of Embracing Localization Inaccuracy - A Case Study
![Page 1: Embracing Localization Inaccuracy - A Case Study](https://reader034.fdocuments.us/reader034/viewer/2022042715/558e16f91a28ab79788b4695/html5/thumbnails/1.jpg)
Usman Raza
Amy L. Murphy
Gian Pietro Picco
Embracing Localization Inaccuracy:
A Case Study
1
![Page 2: Embracing Localization Inaccuracy - A Case Study](https://reader034.fdocuments.us/reader034/viewer/2022042715/558e16f91a28ab79788b4695/html5/thumbnails/2.jpg)
2
Localization in wireless sensor networks has been studied for
a decade now
Increasing complex localization techniques to achieve tens of
cm accuracy
Use costly specialized hardware (UWB, Antenna arrays)
Experiences from the real environments are still limited!
Motivation
![Page 3: Embracing Localization Inaccuracy - A Case Study](https://reader034.fdocuments.us/reader034/viewer/2022042715/558e16f91a28ab79788b4695/html5/thumbnails/3.jpg)
Goals of This Work
3
Not to propose yet another localization technique
Evaluate localization techniques in a real-world nursing home
Requirement are representative of diverse localization systems
Unveil the relationship between system level performance and application level objectives
What a WSN geek want? vs. What an end user want?
To give guidelines to improve both the system level performance and end user satisfaction
![Page 4: Embracing Localization Inaccuracy - A Case Study](https://reader034.fdocuments.us/reader034/viewer/2022042715/558e16f91a28ab79788b4695/html5/thumbnails/4.jpg)
4 4
Higher quality of life for impaired and elderly in nursing homes
Monitoring to the medical support staff
A single floor of a nursing home in Trento, Italy
• 10 Public spaces, 20 Patients, 4 Nurses
![Page 5: Embracing Localization Inaccuracy - A Case Study](https://reader034.fdocuments.us/reader034/viewer/2022042715/558e16f91a28ab79788b4695/html5/thumbnails/5.jpg)
Monitoring in Nursing Homes - Services
5
Doctors
Offline evaluation of patient movement
To assess the general health of the patient
To diagnose the progression of Alzheimer's disease
Nurses
Real time use of approximate patient location
To find the patient
To raise an alarm if patient leaves the facility
![Page 6: Embracing Localization Inaccuracy - A Case Study](https://reader034.fdocuments.us/reader034/viewer/2022042715/558e16f91a28ab79788b4695/html5/thumbnails/6.jpg)
6
WSN Localization - Architecture
Anchors(x,y)
Mobile
Proximity Detection Localization Technique
Localization
![Page 7: Embracing Localization Inaccuracy - A Case Study](https://reader034.fdocuments.us/reader034/viewer/2022042715/558e16f91a28ab79788b4695/html5/thumbnails/7.jpg)
7 7
WSN Localization - Architecture
Anchors(x,y)
Mobile
Proximity Detection Localization Technique
Localization
Localization Technique
![Page 8: Embracing Localization Inaccuracy - A Case Study](https://reader034.fdocuments.us/reader034/viewer/2022042715/558e16f91a28ab79788b4695/html5/thumbnails/8.jpg)
8 8
WSN Localization - Architecture
Anchors(x,y)
Mobile
Proximity Detection Localization Technique
Localization
Localization Technique Proximity Detection
(x,y) (x,y)
(x,y)
![Page 9: Embracing Localization Inaccuracy - A Case Study](https://reader034.fdocuments.us/reader034/viewer/2022042715/558e16f91a28ab79788b4695/html5/thumbnails/9.jpg)
9
WSN Localization - Architecture
Anchors(x,y)
Mobile
Proximity Detection Localization Technique
Localization
Localization Technique Proximity Detection
(x,y) (x,y)
(x,y)
Visualization
Mobile(x,y)
![Page 10: Embracing Localization Inaccuracy - A Case Study](https://reader034.fdocuments.us/reader034/viewer/2022042715/558e16f91a28ab79788b4695/html5/thumbnails/10.jpg)
10
WSN Localization - Architecture
Anchors(x,y)
Mobile
Proximity Detection Localization Technique
Localization
Localization Technique Proximity Detection
(x,y) (x,y)
(x,y)
Visualization
Mobile(x,y)
WSN geek – How far is the estimate to the actual position?
Nurse – Does the visualization allows me to find the patient?
![Page 11: Embracing Localization Inaccuracy - A Case Study](https://reader034.fdocuments.us/reader034/viewer/2022042715/558e16f91a28ab79788b4695/html5/thumbnails/11.jpg)
11
Objective
Identify the proximity of the mobile
patient to an anchor
Requirement – Low maintenance
Energy Efficiency
Localization
Step 1– Proximity Detection
Sleep Box-MAC-LPL Anchor
Mobile Sleep Sleep
Visualization Refresh Interval
Localization Technique
Lifetime Anchors - 45 days (2 AA batteries)
Mobile - 5 days (1 coin battery)
System Design
A custom proximity detection protocol
![Page 12: Embracing Localization Inaccuracy - A Case Study](https://reader034.fdocuments.us/reader034/viewer/2022042715/558e16f91a28ab79788b4695/html5/thumbnails/12.jpg)
12
Max-RSSI Localization
Localizes patient at the anchor detecting proximity with maximum signal strength
Patient
Proximity Detection Localization
Step 2– Localization Techniques
![Page 13: Embracing Localization Inaccuracy - A Case Study](https://reader034.fdocuments.us/reader034/viewer/2022042715/558e16f91a28ab79788b4695/html5/thumbnails/13.jpg)
13
Max-RSSI Localization
Localizes patient at the anchor detecting proximity with maximum signal strength
Relative Span Exponential
Weighted Localization (REWL)
Localizes patient at weighted
centroid of all anchor coordinates
Patient Patient
Proximity Detection Localization
Step 2– Localization Techniques
![Page 14: Embracing Localization Inaccuracy - A Case Study](https://reader034.fdocuments.us/reader034/viewer/2022042715/558e16f91a28ab79788b4695/html5/thumbnails/14.jpg)
Experimental Evaluation
14
System level: WSN geek’s perspective
Accuracy: Percentage of time the patient is correctly detected
in its current area/room
Application level: Nurse's Perspective
Satisfaction level : moderate, fair, excellent!
![Page 15: Embracing Localization Inaccuracy - A Case Study](https://reader034.fdocuments.us/reader034/viewer/2022042715/558e16f91a28ab79788b4695/html5/thumbnails/15.jpg)
System Level Evaluation - Accuracy
Max
-RSS
I R
EW
L
82%
87% 77%
89%
89%
94%
92% 72%
85%
95%
78% 72%
91%
97%
95%
91% 60%
88%
Living Area
Corridor
Bedroom
Bathroom
Living Area
Living Area
Corridor
Bedroom
Bathroom
Living Area
- Reasonable accuracy
- No clear winner
- REWL outperforms in
key areas e.g. living and
exit areas
15
![Page 16: Embracing Localization Inaccuracy - A Case Study](https://reader034.fdocuments.us/reader034/viewer/2022042715/558e16f91a28ab79788b4695/html5/thumbnails/16.jpg)
Application Level Evaluation -
Methodology
16
Nurse
Operator was asked to evaluate multiple localization and
visualizations
Find the patient
Raise an alarm
Patient Icon
Patient Tracking GUI
![Page 17: Embracing Localization Inaccuracy - A Case Study](https://reader034.fdocuments.us/reader034/viewer/2022042715/558e16f91a28ab79788b4695/html5/thumbnails/17.jpg)
Application Level Evaluation - Results
17
Quality of localization system depends heavily on the
visualization
Moderate Excellent! Fair
Max RSSI - at anchor REWL - at x,y Max RSSI- at room center
![Page 18: Embracing Localization Inaccuracy - A Case Study](https://reader034.fdocuments.us/reader034/viewer/2022042715/558e16f91a28ab79788b4695/html5/thumbnails/18.jpg)
18
Low Accuracy ≠ Unacceptable solution to end user
REWL 72%
65% 52% 84% 79% 57%
91%
Living Area
Corridor
Bedroom
Bathroom
Living Area
34%
Experience with our Initial deployment:
Low accuracy
Positive qualitative evaluation
Application Level Evaluation - Results
![Page 19: Embracing Localization Inaccuracy - A Case Study](https://reader034.fdocuments.us/reader034/viewer/2022042715/558e16f91a28ab79788b4695/html5/thumbnails/19.jpg)
Guidelines for Anchor Placement
19
Maximize the distance between anchor nodes deployed in the adjacent areas
Place the nodes near the center of the monitored area
Use the radio shieling of
obstacle to your advantage!
Principle: Minimize the likelihood of signal reception across the
monitored areas
![Page 20: Embracing Localization Inaccuracy - A Case Study](https://reader034.fdocuments.us/reader034/viewer/2022042715/558e16f91a28ab79788b4695/html5/thumbnails/20.jpg)
Conclusion
20
Simple low cost localization system is enough
for many applications
Low accuracy can still be acceptable to end
user
![Page 21: Embracing Localization Inaccuracy - A Case Study](https://reader034.fdocuments.us/reader034/viewer/2022042715/558e16f91a28ab79788b4695/html5/thumbnails/21.jpg)
21
Usman Raza, Amy Murphy, Gian Pietro Picco, “Embracing Localization Inaccuracy – A Case
Study ”, April 2013, IEEE International Conference on Intelligent Sensors, Sensor Networks
and Information Processing (ISSNIP), Melbourne, Australia
Full Text (Pre-print) : http://disi.unitn.it/~raza/Papers/DISI_TR_12_038.pdf
Thank You!