2
Water Metering Q200 DN15 Product Specification METROLOGICAL CHARACTERISTICS Nominal Pipe Diameter DN mm 15 Permanent Flow Q 3 m 3 /h (gpm) 2.5 (11) Measuring Range Q 3 /Q 1 250 200 160 Minimum Flow Q 1 l/h (gpm) 10 12.5 15.6 (0.07) Transitional Flow Q 2 l/h 16 20 25 Overload Flow Q 4 m 3 /h (gpm) 3.125 (13.75) Accuracy Class 2 TECHNICAL CHARACTERISTICS Typical pressure loss at Q 3 bar (PSI) <0.63 (<9.2) Pressure rating (working) bar (PSI) 16 (232) Max. pressure rating bar (PSI) 20 (290) Ambient operating temp. °C (F) -10 to +85 (14 to 185) Ambient storage temp. °C (F) -10 to +70 (14 to 158) Temperature class T30 Electromagnetic class E1 Environmental class B & C Nominal diameter DN mm 15 Thread size in G ¾” Lay-length mm (in) 110 +0/-2 (4 +0/-⅟ ₁₆) Weight kg (lbs) 0.5 (1.1) Indicating range m 3 (gallon) 99,999 (9,999,999) Display resolution m 3 (gallon) 0.00001 (0.001) Typical battery life years 15 Ingress protection IP 68 Operation The Q200 is a fluidic oscillator type, cold water meter. Water enters the fluidic oscillator through a nozzle that creates a jet. When the jet enters the flow chamber, it will initially be drawn to one of the two diffuser walls and will travel along the wall through the principle of the Coandã effect and then exit the flow chamber. Due to the local pressure being lower by the opposite diffuser wall, the jet will move towards the other wall and therefore starts to oscillate between one diffuser wall and the other. Carefully optimized features within the flow chamber provide oscillation across a greater flow range. This oscillation between the diffuser walls continues while flow is present where each oscillation represents a precise volume that has passed through the meter. The oscillation is monitored by electrodes placed next to each diffuser wall, in which an electrical current is induced in the jet by a pair of powerful permanent magnets. Sensing electronics capture when the oscillations occur and totalize the volume passed displaying the registered volume on a liquid crystal display. When no fluid present i.e. air, no signal is present and no volume measured. Application The meter is for use only with potable cold water up to 50 °C (122F) and an overload pressure up to 20 bar (290 PSI). The meter will register between 98% and 102% accurate throughout the normal operating range and between 95% and 105% at the low flow for accuracy class 2, T30 temperature class meters, as stated within OIML R49-1:2006. No adjustment is required before or after installation and the in-service accuracy errors can be up to twice that of the rated accuracy class. MATERIALS Measuring chamber PPS Sensor electrodes Hastelloy Conditioning plate Acetal Strainer Acetal Non-return valve Acetal Enclosure o-ring Neoprene Enclosure Polycarbonate Lid Acetal Battery Lithium Thionyl Chloride

Transcript of ELS10323 Q200 DN15 m3 Specsheet V5 HW · Water tering Q200D N15 Product Specification METROLOGICAL...

Page 1: ELS10323 Q200 DN15 m3 Specsheet V5 HW · Water tering Q200D N15 Product Specification METROLOGICAL CHARACTERISTICS Nominal Pipe Diameter DN mm 15 Permanent Flow Q 3 m3/h (gpm) 2.5

Water Metering

Q200 DN15Product Specification

METROLOGICAL CHARACTERISTICS

Nominal Pipe Diameter DN mm 15

Permanent Flow Q3 m3/h (gpm) 2.5 (11)

Measuring Range Q3/Q1 250 200 160

Minimum Flow Q1 l/h (gpm) 10 12.5 15.6 (0.07)

Transitional Flow Q2 l/h 16 20 25

Overload Flow Q4 m3/h (gpm) 3.125 (13.75)

Accuracy Class 2

TECHNICAL CHARACTERISTICS

Typical pressure loss at Q3 bar (PSI) <0.63 (<9.2)

Pressure rating (working) bar (PSI) 16 (232)

Max. pressure rating bar (PSI) 20 (290)

Ambient operating temp. °C (F) -10 to +85 (14 to 185)

Ambient storage temp. °C (F) -10 to +70 (14 to 158)

Temperature class T30

Electromagnetic class E1

Environmental class B & C

Nominal diameter DN mm 15

Thread size in G ¾”

Lay-length mm (in) 110 +0/-2 (4 1/3 +0/-⅟₁₆)

Weight kg (lbs) 0.5 (1.1)

Indicating range m3 (gallon) 99,999 (9,999,999)

Display resolution m3 (gallon) 0.00001 (0.001)

Typical battery life years 15

Ingress protection IP 68

OperationThe Q200 is a fluidic oscillator type, cold water meter. Water enters

the fluidic oscillator through a nozzle that creates a jet. When the

jet enters the flow chamber, it will initially be drawn to one of the two

diffuser walls and will travel along the wall through the principle of

the Coandã effect and then exit the flow chamber. Due to the local

pressure being lower by the opposite diffuser wall, the jet will move

towards the other wall and therefore starts to oscillate between

one diffuser wall and the other. Carefully optimized features within

the flow chamber provide oscillation across a greater flow range.

This oscillation between the diffuser walls continues while flow is present

where each oscillation represents a precise volume that has passed

through the meter. The oscillation is monitored by electrodes placed

next to each diffuser wall, in which an electrical current is induced in

the jet by a pair of powerful permanent magnets. Sensing electronics

capture when the oscillations occur and totalize the volume passed

displaying the registered volume on a liquid crystal display. When no

fluid present i.e. air, no signal is present and no volume measured.

ApplicationThe meter is for use only with potable cold water

up to 50 °C (122F) and an overload pressure

up to 20 bar (290 PSI). The meter will register

between 98% and 102% accurate throughout

the normal operating range and between 95%

and 105% at the low flow for accuracy class

2, T30 temperature class meters, as stated

within OIML R49-1:2006. No adjustment

is required before or after installation and

the in-service accuracy errors can be up

to twice that of the rated accuracy class.

MATERIALS

Measuring chamber PPS

Sensor electrodes Hastelloy

Conditioning plate Acetal

Strainer Acetal

Non-return valve Acetal

Enclosure o-ring Neoprene

Enclosure Polycarbonate

Lid Acetal

Battery Lithium Thionyl Chloride

Page 2: ELS10323 Q200 DN15 m3 Specsheet V5 HW · Water tering Q200D N15 Product Specification METROLOGICAL CHARACTERISTICS Nominal Pipe Diameter DN mm 15 Permanent Flow Q 3 m3/h (gpm) 2.5

For more informationwww.elstermetering.com

Elster Water Metering Ltd 130 Camford Way

Sundon Park, Luton

Bedfordshire, LU3 3AN

United Kingdom

T +44 1582 846400

F +44 1582 564728

[email protected]

All rights reserved. The company’s policy is one of continuous product improvement and the right is reserved to modify the specifications contained herein without notice. These products have been manufactured with current technology and in accordance with the applicable referenced standards.

Rev.1 Q200 DN15 m3 Specsheet 04/19 Lit Ref: 8519B93233© 2019 Honeywell International Inc.

REGISTERThe register is contained within an advanced engineered polymer enclosure which is completely potted to eliminate air and any potential condensation. To assure easy reading, the totalizer LCD digits are large and the dial face is colour coded to identify billing units and verification units. The applicable flow range, type approval and registration units are printed on the dial face. The 10 digit LCD includes a low-flow indicator that provides visual indication of a perceived water leak. The register contains a removable Lithium Thionyl Chloride battery pack that has a typical 15 year battery life under normal operating conditions.

READING THE METERThe reading is displayed on the electronic register of the meter under the protective lid.

Cubic MetreThe display digits before the decimal point, surrounded by a black border, represent the standard billing units in whole cubic metres (m3) and the digits after the decimal point, surrounded by a red border represent fractions of a cubic metre.

Billing units Decimal fraction

Standard billing unit = 1 cubic metre

m3

5/8"NSF®-61-G

Q700

m3

GallonsThe display digits surrounded by a white border represent the standard billing units in thousand gallons and the digits surrounded by the black and red border, represent the non-billing units in gallons and fractions of a gallon.

Billing units Non billing units

Standard billing unit = 1,000 gallons

Gallon5/8"NSF®-61-G

Q700

m3

When water is flowing, a flashing square icon appears to the lower right of the display, but when the flow has stopped this indicator will be extinguished. To read the meter using a remote reading system, refer to the manufacturer’s instructions.

CONSTRUCTIONThe construction of the Q200 meters comply with the requirements of the OIML R49-1: 2006 and WRAS specifications. The meter consists of a combined single piece polymer main case with threaded ends and fluidic oscillator measuring chamber with no moving parts, and an electronic register assembly that is attached onto the measuring chamber.

The measuring chamber is moulded from first grade PPS and has raised characters designating model, size and direction of flow. The fluidic oscillator measuring chamber uses patented magnet sensing with inset moulded sensor electrodes to monitor flow.

The Q200 meter can be optionally fitted with brass thread sleeves bonded to the polymer threads.

AMR/AMI CONNECTIVITYThe Q200 meter is supplied AMR ready with an integral communication cable that is factory set to support one of the following output modes:

• Encoder output that uses standard ASCII serial protocols

• Pulse output with default setting 1 pulse per litre

Suitable connector cable options can be supplied for connection to Elster compatible devices.

APPROVALSMeter manufacture and performance specification

• OIML R49

• IS04064

• WRAS (UK)

Q200 (DN15)

110 +0 2 mm

80Ø

mm

99m

m

18m

m

G 3

/4" B

12.5

Q200 (DN15)

110 +0 2 mm

80Ø

mm

99m

m

18m

m

G 3

/4" B

12.5