Elisa Reader Sirio

1
ReiGed Diagnostics ReiGed Diagnostics : www.ReiGed-Diagnostics.com [email protected] [email protected] SIRIO S Elisa Reader The microplate reader, Sirio S with 8 reading positions, is an extremely flexible and fast automatic photometer, it takes 3 second for each monocromatic reading at any wavelengh for 96 flat boomed and “U” shape well microplate. It perfoms reading in absorbance, end point and kinetic with turbidimetric and agglutination applications. The large liquid cristal display, drives programming as well as visualizarion of all analytical parameters, cut-off, standard curves and final result that will be printed out by the built-in grafic printer. the membrane keyboard helps in the selection of all fuctions.The management soſtware files up to 48 analytical parameter and a maximum of 8 standards for the quantitative methods. For the qualitative test the following controls are provided: negative, cut-off, low positive, positive and high positive. Futher soſtware features provided are - elaboration of reading data in concentration, depending on the interpolarity formula: linear, cubic, and logit-log, - programing of standard curves and samples, - curve and cut-off storage, as reference values, - initialization and self test, which eliminate reading errors.

Transcript of Elisa Reader Sirio

Page 1: Elisa Reader Sirio

ReiGedDiagnostics

ReiGed Diagnostics :[email protected] [email protected]

SIRIO SElisa Reader

The microplate reader, Sirio S with 8 reading positions, is an extremely flexible and fast automatic photometer, it takes 3 second for each monocromatic reading at any wavelengh for 96 flat bottomed and “U” shape well microplate. It perfoms reading in absorbance, end point and kinetic with turbidimetric and agglutination applications.The large liquid cristal display, drives programming as well as visualizarion of all analytical parameters, cut-off, standard curves and final result that will be printed out by the built-in grafic printer. the membrane keyboard helps in the selection of all fuctions.The management software files up to 48 analytical parameter and a maximum of 8 standards for the quantitative methods. For the qualitative test the following controls are provided: negative, cut-off, low positive, positive and high positive.Futher software features provided are- elaboration of reading data in concentration, depending on the interpolarity formula: linear, cubic, and logit-log,- programing of standard curves and samples,- curve and cut-off storage, as reference values,- initialization and self test, which eliminate reading errors.